1
|
Han Z, Komori R, Suzuki R, Omata N, Matsuda T, Hishida S, Shuuhei T, Chen LC. Bipolar Electrospray from Electrodeless Emitters for ESI without Electrochemical Reactions in the Sprayer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:728-736. [PMID: 36815710 DOI: 10.1021/jasms.2c00382] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
A bipolar ESI source is developed to generate a simultaneous emission of charged liquid jets of opposite polarity from an electrodeless sprayer. The sprayer consists of two emitters, and the electrosprays are initiated by applying a high potential difference (HV) across the counter electrodes facing each emitter. The sprayer and the liquid delivery system are made of all insulators without metal components, thus enabling the total elimination of electrochemical reactions taking place at the liquid-electrode interface in the typical electrosprayer. The bipolar electrospray has been implemented using an online configuration that uses a syringe pump for flow rate regulation and an offline configuration that relies on HV for adjusting the flow rate. The voltage-current and flow rate-current relationships of bipolar electrospray were found to be similar to the standard electrospray. The application of bipolar ESI to the mass spectrometry of protein, peptide, and metallocene without electrochemically induced oxidation/reduction is demonstrated.
Collapse
Affiliation(s)
- Zhongbao Han
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Ryoki Komori
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Riku Suzuki
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Nozomu Omata
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Takeshi Matsuda
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Shoki Hishida
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Takiguchi Shuuhei
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Lee Chuin Chen
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| |
Collapse
|
2
|
Han Z, Chen LC. Electrospray Ionization Inside the Ion Inlet Tube: Multijet Mode Operation. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1821-1828. [PMID: 34167294 DOI: 10.1021/jasms.1c00157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We investigated the electrospray ionization inside the narrow channel of the ion inlet tube. An insulating emitter capillary made of fused silica with a 0.2 mm outer diameter was inserted into the ion inlet tubes with a 0.5 and 0.6 mm inner diameter to aspirate all the charged droplets. A custom-made ion inlet tube with two side holes near its entrance is used to observe the spraying condition. The spray current is measured and monitored during the MS acquisition using isolation amplifiers. Because the emitter is cylindrically surrounded in close proximity by the metallic inner wall, it is difficult to obtain a stable and symmetric Taylor cone with its apex at the center of the emitter. Instead, a stable operation under a flow rate of 1-4 μL/min is found to be in the form of a multicone-jet mode with two or more Taylor cones anchoring around the rim of the emitter. The emitted charged droplet jets are dragged from hitting the wall by the fast-flowing air inside the inlet tube. Comparison with the typical cone-jet and multijet mode operated several millimeters outside the inlet capillary shows signal enhancements for protein standards.
Collapse
Affiliation(s)
- Zhongbao Han
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| | - Lee Chuin Chen
- Faculty of Engineering, University of Yamanashi, 4-3-11, Takeda, Kofu, Yamanashi 400-8511, Japan
| |
Collapse
|
3
|
Rovelli G, Jacobs MI, Willis MD, Rapf RJ, Prophet AM, Wilson KR. A critical analysis of electrospray techniques for the determination of accelerated rates and mechanisms of chemical reactions in droplets. Chem Sci 2020; 11:13026-13043. [PMID: 34094487 PMCID: PMC8163298 DOI: 10.1039/d0sc04611f] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Accepted: 10/25/2020] [Indexed: 12/14/2022] Open
Abstract
Electrospray and Electrosonic Spray Ionization Mass Spectrometry (ESI-MS and ESSI-MS) have been widely used to report evidence that many chemical reactions in micro- and nano-droplets are dramatically accelerated by factors of ∼102 to 106 relative to macroscale bulk solutions. Despite electrospray's relative simplicity to both generate and detect reaction products in charged droplets using mass spectrometry, substantial complexity exists in how the electrospray process itself impacts the interpretation of the mechanism of these observed accelerated rates. ESI and ESSI are both coupled multi-phase processes, in which analytes in small charged droplets are transferred and detected as gas-phase ions with a mass spectrometer. As such, quantitative examination is needed to evaluate the impact of multiple experimental factors on the magnitude and mechanisms of reaction acceleration. These include: (1) evaporative concentration of reactants as a function of droplet size and initial concentration, (2) competition from gas-phase chemistry and reactions on experimental surfaces, (3) differences in ionization efficiency and ion transmission and (4) droplet charge. We examine (1-4) using numerical models, new ESI/ESSI-MS experimental data, and prior literature to assess the limitations of these approaches and the experimental best practices required to robustly interpret acceleration factors in micro- and nano-droplets produced by ESI and ESSI.
Collapse
Affiliation(s)
- Grazia Rovelli
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
| | - Michael I Jacobs
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
- Department of Chemistry, University of California Berkeley 94720 CA USA
| | - Megan D Willis
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
| | - Rebecca J Rapf
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
| | - Alexander M Prophet
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
- Department of Chemistry, University of California Berkeley 94720 CA USA
| | - Kevin R Wilson
- Chemical Sciences Division, Lawrence Berkeley National Laboratory Berkeley 94720 CA USA
| |
Collapse
|
4
|
A comparative study on droplet characteristics and specific charge of ethanol in two small-scale electrospray systems. Sci Rep 2019; 9:18791. [PMID: 31827156 PMCID: PMC6906519 DOI: 10.1038/s41598-019-55223-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Accepted: 11/13/2019] [Indexed: 11/08/2022] Open
Abstract
An investigation on the droplet characteristics of ethanol in small-scale combustors with two different systems was conducted experimentally and theoretically. The classical capillary-mesh electrode arrangement was applied in Type A electrospray system, and for Type B, an additional ring electrode is included. The droplet size and velocity were measured by a Phase Doppler Anemometer. The electric filed intensity was theoretically calculated in the two electrospray systems. Compared with Type A, Type B system has smaller droplet size and velocity in the same spraying mode. Meanwhile the electrospray process in Type B system is more stable than that in Type A with its smaller root mean square velocity. By measuring the spraying current, the average specific charge of the droplets for the two systems was obtained in different spraying modes. And it was found that the addition of the ring electrode can help to increase the droplet charge, which is the fundamental reason for Type B electrospray system to perform better. The corona charge of the droplets was theoretically calculated for the two electrospray systems. It was found that the calculated specific charge generated by corona charging was in good agreement with the experimental results.
Collapse
|