1
|
Zapata Flores EDJ, Herodes K, Leito I. Comparison of the ionisation mode in the determination of free amino acids in beers by Liquid Chromatography tandem mass spectrometry. J Chromatogr A 2022; 1677:463320. [PMID: 35870275 DOI: 10.1016/j.chroma.2022.463320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 11/15/2022]
Abstract
A comparison of positive and negative ionization modes in LC-ESI-MS/MS was carried out for the analysis of derivatized amino acids in 15 different beer samples. 22 free amino acids were derivatized using Diethyl ethoxymethylenemalonate (DEEMM) and their content was determined. When using the DEEMM as derivatization reagent the negative ionization mode provided analytical performance equal to or in some cases even superior to the positive ionization mode. For 6 amino acids (Thr, β-Ala, α-Ala, Met, Val and Orn) the negative mode led to lower LoQ values, while the positive mode offered lower LoQ values for 5 amino acids (Arg, Asp, Glu, GABA, and Pro). The remaining 11 amino acids showed similar LoQ values in both modes. Because of this, negative ionization mode allowed to detect and quantify amino acids such as: β-Alanine, threonine, and ornithine whose concentrations were low in most of the analysed samples. The relative standard deviation (RSD) for the results in both modes were similar. The method's linearity was determined to be in the range of 1 to 130 ppb with r2 > 0.99. Recoveries ranged from 93 to 112%. Negative mode was less affected by matrix effects the main effect was signal enhancement. In contrast, the positive ionization mode suffered from signal enhancement as well as signal suppression.
Collapse
Affiliation(s)
| | - Koit Herodes
- University of Tartu, Institute on Chemistry, Ravila 14a, Tartu 50411, Estonia
| | - Ivo Leito
- University of Tartu, Institute on Chemistry, Ravila 14a, Tartu 50411, Estonia
| |
Collapse
|
2
|
Oss M, Tshepelevitsh S, Kruve A, Liigand P, Liigand J, Rebane R, Selberg S, Ets K, Herodes K, Leito I. Quantitative electrospray ionization efficiency scale: 10 years after. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9178. [PMID: 34355441 DOI: 10.1002/rcm.9178] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 08/02/2021] [Accepted: 08/02/2021] [Indexed: 06/13/2023]
Abstract
RATIONALE The first comprehensive quantitative scale of the efficiency of electrospray ionization (ESI) in the positive mode by monoprotonation, containing 62 compounds, was published in 2010. Several trends were found between the compound structure and ionization efficiency (IE) but, possibly because of the limited diversity of the compounds, some questions remained. This work undertakes to align the new data with the originally published IE scale and carry out statistical analysis of the resulting more extensive and diverse data set to derive more grounded relationships and offer a possibility of predicting logIE values. METHODS Recently, several new IE studies with numerous compounds have been conducted. In several of them, more detailed investigations of the influence of compound structure, solvent properties, or instrument settings have been conducted. IE data from these studies and results from this work were combined, and the multilinear regression method was applied to relate IE to various compound parameters. RESULTS The most comprehensive IE scale available, containing 334 compounds of highly diverse chemical nature and spanning 6 orders of magnitude of IE, has been compiled. Several useful trends were revealed. CONCLUSIONS The ESI ionization efficiency of a compound by protonation is mainly affected by three factors: basicity (expressed by pKaH in water), molecular size (expressed by molar volume or surface area), and hydrophobicity of the ion (expressed by charge delocalization in the ion or its partition coefficient between a water-acetonitrile mixture and hexane). The presented models can be used for tentative prediction of logIE of new compounds (under the used conditions) from parameters that can be computed using commercially available software. The root mean square error of prediction is in the range of 0.7-0.8 log units.
Collapse
Affiliation(s)
- Merit Oss
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | | | - Anneli Kruve
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Piia Liigand
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Jaanus Liigand
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Riin Rebane
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Sigrid Selberg
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Kristel Ets
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Koit Herodes
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Tartu, Estonia
| |
Collapse
|
3
|
Heininen J, Julku U, Myöhänen T, Kotiaho T, Kostiainen R. Multiplexed analysis of amino acids in mice brain microdialysis samples using isobaric labeling and liquid chromatography-high resolution tandem mass spectrometry. J Chromatogr A 2021; 1656:462537. [PMID: 34537659 DOI: 10.1016/j.chroma.2021.462537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 08/26/2021] [Accepted: 09/01/2021] [Indexed: 11/29/2022]
Abstract
We developed a new multiplexed reversed phase liquid chromatography-high resolution tandem mass spectrometric (LC-MS/MS) method. The method is based on isobaric labeling with a tandem mass tag (TMT10-plex) and stable isotope-labeled internal standards, and was used to analyze amino acids in mouse brain microdialysis samples. The TMT10-plex labeling of amino acids allowed analysis of ten samples in one LC-MS/MS run, significantly increasing the sample throughput. The method provides good chromatographic performance (peak half-width between 0.04-0.12 min), allowing separation of all TMT-labeled amino acids with acceptable resolution and high sensitivity (limits of detection typically around 10 nM). The use of stable isotope-labeled internal standards, together with TMT10-plex labeling, ensured good repeatability (relative standard deviation ≤ 12.1 %) and linearity (correlation coefficient > 0.994), indicating good quantitative performance of the multiplexed method. The method was applied to study the effect of d-amphetamine microdialysis perfusion on amino acid concentrations in the mouse brain. All amino acids were reliably detected and quantified, indicating that the method is sensitive enough to detect low concentrations of amino acids in brain microdialysis samples.
Collapse
Affiliation(s)
- Juho Heininen
- Drug Research Program and Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland
| | - Ulrika Julku
- Division of Pharmacology and Pharmacotherapy, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland
| | - Timo Myöhänen
- Division of Pharmacology and Pharmacotherapy, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland
| | - Tapio Kotiaho
- Drug Research Program and Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland; Department of Chemistry, Faculty of Science, University of Helsinki, P.O. Box. 55, FIN-00014, Finland
| | - Risto Kostiainen
- Drug Research Program and Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, FI-00014, Finland.
| |
Collapse
|
4
|
Xiao HM, Yang X, Zheng F, Tshepelevitsh S, Wang X, Yao XJ, Leito I, Feng YQ. Quantitative analysis of the relationship of derivatization reagents and detection sensitivity of electrospray ionization-triple quadrupole tandem mass spectrometry: Hydrazines as prototypes. Anal Chim Acta 2021; 1158:338402. [PMID: 33863407 DOI: 10.1016/j.aca.2021.338402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/21/2021] [Accepted: 03/07/2021] [Indexed: 11/30/2022]
Abstract
Chemical derivatization-assisted electrospray ionization-triple quadrupole mass spectrometry (ESI-QqQ-MS) has become an efficient tool for the quantification of low-molecular-weight molecules. Many studies found that the derivatives of the same analytes derivatized by different derivatization reagents with the same reaction group had different detection sensitivity, even under the same conditions of electrospray ionization-mass spectrometry (ESI-MS). This phenomenon was suggested to be caused by the different modifying groups in the derivatization reagents. However, there is still a lack of systematic study on how modifying groups in the derivatization reagents affect the detection sensitivity of their corresponding derivatives of analytes, especially theoretical investigations. In this study, we employed a quantitative structure-activity relationship (QSAR) modeling approach to explore the relationship between modifying group structures and the detection sensitivity of derivatization reagents and their derivatives during ESI-MS detection. A total of 110 derivatization reagents of the hydrazine family and their hexanal derivatives (substituted hydrazones) were selected as the prototypes to construct QSAR models. The established models suggested that several molecular descriptors, related to hydrophobicity, electronegativity, and molecular shape, were related to the detection sensitivity of hexanal derivatives induced by different modifying groups in the derivatization reagents. Besides, we found that the detection sensitivity of compounds detected in selected ion mode (SIM) showed a positive correlation with that obtained in multiple reaction monitoring mode (MRM), and the ionization efficiency was the key factor on the detection sensitivity in both modes.
Collapse
Affiliation(s)
- Hua-Ming Xiao
- Department of Chemistry, Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan, 430072, PR China; Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, PR China
| | - Xing Yang
- State Key Laboratory of Applied Organic Chemistry, Department of Chemistry, Lanzhou University, Lanzhou, 73000, PR China
| | - Feng Zheng
- Department of Chemistry, Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan, 430072, PR China
| | - Sofja Tshepelevitsh
- Institute of Chemistry, University of Tartu, 14a Ravila Street, Tartu, 50411, Estonia
| | - Xian Wang
- Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science, South-Central University for Nationalities, Wuhan, 430074, PR China.
| | - Xiao-Jun Yao
- State Key Laboratory of Applied Organic Chemistry, Department of Chemistry, Lanzhou University, Lanzhou, 73000, PR China
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, 14a Ravila Street, Tartu, 50411, Estonia
| | - Yu-Qi Feng
- Department of Chemistry, Frontier Science Center for Immunology and Metabolism, Wuhan University, Wuhan, 430072, PR China.
| |
Collapse
|
5
|
Lee W, Um J, Ko KH, Lee YC, Chung BC, Hong J. UHPLC-MS/MS profiling of histidine and bile acid metabolism in human gastric fluid for diagnosis of gastric diseases. J Anal Sci Technol 2020. [DOI: 10.1186/s40543-020-00218-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
AbstractBile acids (BAs) are synthesized in the liver and can mediate homeostasis and various metabolism processes in the human body. Their levels in the gastrointestinal tract are closely related to various gastrointestinal diseases. In particular, farnesoid X receptor activated by free BAs is associated with overexpression of histidine decarboxylase in tumorigenesis. Therefore, comprehensive profiling of histamine (HIST), histidine (His), and BAs in biological samples can provide insight into the pathological mechanisms of gastrointestinal diseases. However, development of an analytical platform to profile HIST, His, and BAs in biological samples has several challenges such as highly different polarities between acidic and basic targets, low physiological concentrations of analytes, and high matrix interference of biological samples. In this study, an ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method combined with serial derivatization was developed to simultaneously determine HIST, His, and 5 BAs (cholic acid, deoxycholic acid, chenodeoxycholic acid, ursodeoxycholic acid, and lithocholic acid) in human gastric fluid. In serial derivatization, benzoyl chloride (BzCl) and N,N-dimethylethylenediamine (DMED) were used to selectively derivatize amino and carboxyl groups of analytes, respectively. After serial derivatization, all target derivatives were determined using a reverse-phase C18 LC column and positive multiple reaction monitoring (MRM) mode, with reasonable chromatographic separation and sensitive MS detection. To accurately quantify target metabolites, 7 stable isotope-labeled internal standards were used. The MS/MS spectra of DMED and Bz derivatives exhibited specific fragments via loss of a neutral molecule (dimethylamine; 45 Da) and inductive cleavage (benzoyl; m/z 105) from protonated molecules, enabling selection of appropriate MRM transition ions for selective and sensitive detection. The developed method was validated with respect to limits of detection and quantification, linearity, precision, accuracy, stability, and matrix effect. The established method was successfully applied to human gastric fluid samples. This method provides reliable quantification of HIST, His, and BAs in human gastric fluid and will be helpful to understand pathophysiological mechanisms of gastric diseases.
Collapse
|
6
|
Rebane R, Kruve A, Liigand J, Liigand P, Gornischeff A, Leito I. Ionization efficiency ladders as tools for choosing ionization mode and solvent in liquid chromatography/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:1834-1843. [PMID: 31381213 DOI: 10.1002/rcm.8545] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 07/26/2019] [Accepted: 07/29/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE The choice of mobile phase components and optimal ion source, mainly electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI), is a crucial part in liquid chromatography/mass spectrometry (LC/MS) method development to achieve higher sensitivity and lower detection limits. In this study we demonstrate how to rigorously solve these questions by using ionization efficiency scales. METHODS Four ionization efficiency scales are used: recorded with both APCI and ESI sources and using both methanol- and acetonitrile-containing mobile phases. Each scale contains altogether more than 50 compounds. In addition, measurements with a chromatographic column were also performed. RESULTS We observed a correlation between calibration graph slopes under LC conditions and logIE values in ESI (but not APCI) thereby validating the use of logIE values for choosing the ion source. Most of the studied compounds preferred ESI as an ion source and methanol as mobile organic phase. APCI remains the ion source of choice for polycyclic aromatic hydrocarbons. For APCI, both acetonitrile and methanol provide similar ionization efficiencies with few exceptions. CONCLUSIONS Overall the results of this work give a concise guideline for practitioners in choosing an ion source for LC/MS analysis on the basis of the chemical nature of the analytes.
Collapse
Affiliation(s)
- Riin Rebane
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Anneli Kruve
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Jaanus Liigand
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Piia Liigand
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Artur Gornischeff
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| | - Ivo Leito
- Institute of Chemistry, University of Tartu, Ravila 14a, 50411, Tartu, Estonia
| |
Collapse
|
7
|
Ferré S, González-Ruiz V, Guillarme D, Rudaz S. Analytical strategies for the determination of amino acids: Past, present and future trends. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1132:121819. [PMID: 31704619 DOI: 10.1016/j.jchromb.2019.121819] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 09/25/2019] [Accepted: 09/27/2019] [Indexed: 12/27/2022]
Abstract
This review describes the analytical methods that have been developed over the years to tackle the high polarity and non-chromophoric nature of amino acids (AAs). First, the historical methods are briefly presented, with a strong focus on the use of derivatization reagents to make AAs detectable with spectroscopic techniques (ultraviolet and fluorescence) and/or sufficiently retained in reversed phase liquid chromatography. Then, an overview of the current analytical strategies for achiral separation of AAs is provided, in which mass spectrometry (MS) becomes the most widely used detection mode in combination with innovative liquid chromatography or capillary electrophoresis conditions to detect AAs at very low concentration in complex matrixes. Finally, some future trends of AA analysis are provided in the last section of the review, including the use of supercritical fluid chromatography (SFC), multidimensional liquid chromatography and electrophoretic separations, hyphenation of ion exchange chromatography to mass spectrometry, and use of ion mobility spectrometry mass spectrometry (IM-MS). Various application examples will also be presented throughout the review to highlight the benefits and limitations of these different analytical approaches for AAs determination.
Collapse
Affiliation(s)
- Sabrina Ferré
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Víctor González-Ruiz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| | - Serge Rudaz
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Swiss Centre for Applied Human Toxicology (SCAHT), Switzerland
| |
Collapse
|
8
|
Engelen MPKJ, Ten Have GAM, Thaden JJ, Deutz NEP. New advances in stable tracer methods to assess whole-body protein and amino acid metabolism. Curr Opin Clin Nutr Metab Care 2019; 22:337-346. [PMID: 31192825 DOI: 10.1097/mco.0000000000000583] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
PURPOSE OF REVIEW Stable isotope methods have been used for many years to assess whole-body protein and amino acid kinetics in healthy conditions and in response to aging, exercise and (clinically stable) disease states. RECENT FINDINGS In recent years, tracer research expanded to the anabolic response to feeding in critical illness and its use during acute metabolic stressors. Furthermore, new isotope approaches and tracer insights have been obtained. In the postabsorptive state, the novel tracer pulse approach has several advantages above the established continuous tracer approach because of the metabolic information that can be obtained, easy applicability, and low tracer costs. The use of bolus versus sip-feeding approaches to assess the anabolic response to a meal is dependent on the research question and its feasibility. Promising new tracer approaches have been developed to measure the anabolic capacity, and protein digestibility and absorption. Advances have been made in the field of mass spectrometry in low enrichment analysis. SUMMARY Novel tracer approaches are available that can more readily be used in critical illness and during acute metabolic stressors. Besides the use of tracer application in various clinical conditions, more research is needed on how to incorporate isotopes on an individual level.
Collapse
Affiliation(s)
- Mariëlle P K J Engelen
- Department of Health and Kinesiology, Center for Translational Research in Aging & Longevity, Texas A&M University, College Station, Texas, USA
| | | | | | | |
Collapse
|