Kaptein BL, Pijls B, Koster L, Kärrholm J, Hull M, Niesen A, Heesterbeek P, Callary S, Teeter M, Gascoyne T, Röhrl SM, Flivik G, Bragonzoni L, Laende E, Sandberg O, Solomon LB, Nelissen R, Stilling M. Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations. Acta Orthop 2024; 95:256-267. [PMID: 38819193 PMCID: PMC11141406 DOI: 10.2340/17453674.2024.40709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 04/08/2024] [Indexed: 06/01/2024] Open
Abstract
Opening remarks: These guidelines are the result of discussions within a diverse group of RSA researchers. They were approved in December 2023 by the board and selected members of the International Radiostereometry Society to update the guidelines by Valstar et al. [1]. By adhering to these guidelines, RSA studies will become more transparent and consistent in execution, presentation, reporting, and interpretation. Both authors and reviewers of scientific papers using RSA may use these guidelines, summarized in the Checklist, as a reference. Deviations from these guidelines should have the underlying rationale stated.
Collapse
Affiliation(s)
- Bart L Kaptein
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands.
| | - Bart Pijls
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Lennard Koster
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Johan Kärrholm
- Department of Orthopedics, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maury Hull
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Abby Niesen
- Orthopedic Surgery Department, University of California, Davis, United States
| | - Petra Heesterbeek
- Orthopedic Research Department, Sint Maartenskliniek, Nijmegen, The Netherlands
| | - Stuart Callary
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Matthew Teeter
- Department of Medical Biophysics, Western University, London, Canada
| | | | - Stephan M Röhrl
- Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway
| | - Gunnar Flivik
- Department of Orthopedics, Skane University Hospital, Lund, Sweden
| | | | - Elise Laende
- Department of Surgery, Dalhousie University, Halifax, Canada
| | | | - L Bogdan Solomon
- Department of Orthopedics and Trauma, Royal Adelaide Hospital, Adelaide, Australia
| | - Rob Nelissen
- Department of Orthopedics, Leiden University Medical Center, Leiden, The Netherlands
| | - Maiken Stilling
- Department of Orthopedics, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
2
|
Taleb S, Broberg JS, Lanting BA, Teeter MG. Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk. Proc Inst Mech Eng H 2024; 238:483-487. [PMID: 38519832 PMCID: PMC11083746 DOI: 10.1177/09544119241238950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2024]
Abstract
Component-on-component impingement in total hip arthroplasty may lead to post-operative complications including dislocation. Despite numerous clinical studies focusing on reducing this risk, assessment methods remain limited to qualitative radiography, finite element analysis, and cadaver studies. There is a need for more precise measurements of impingement in the research setting. We aimed to validate a novel RSA-based impingement metric to measure component-on-component impingement in vivo. A phantom experiment of a standard metal-on-polyethylene total hip system was performed. RSA examinations were performed as typical for a traditional weight-bearing RSA exam for large joints. The phantom was placed in 10 possible impinged positions and one neutral position. Double exposure radiographs were taken to measure repeatability. The closest distance between the skirt of the head and the inner circumference of the acetabular cup liner was measured to assess impingement risk. Distances between the closest point of the hood to the edge of the cup in 10 impinged positions ranged from 0.05 to 1.03 mm, with the average being 0.67 mm. In the neutral position, the distance measured is 11.02 mm. Excellent repeatability was observed, with a standard deviation of 0.03 mm with an r value of 0.09. A validated RSA-based risk metric was established to evaluate in vivo hip impingement. A 1 mm threshold may be proposed to define impingement where distances approaching 1.00 mm are at a greater risk of impingement. This simplified metric holds promise for upcoming clinical studies on component-on-component impingement.
Collapse
Affiliation(s)
- Shahnaz Taleb
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Jordan S Broberg
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Brent A Lanting
- Division of Orthopedic Surgery, Department of Surgery, University Hospital, London Health Sciences Center, London, ON, Canada
| | - Matthew G Teeter
- Imaging Group, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| |
Collapse
|
3
|
Jørgensen PB, Kaptein BL, Søballe K, Jakobsen SS, Stilling M. Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study. Eur Radiol Exp 2021; 5:55. [PMID: 34907467 PMCID: PMC8671599 DOI: 10.1186/s41747-021-00253-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 11/08/2021] [Indexed: 12/02/2022] Open
Abstract
Background Investigation of polyethylene liner movement in total hip arthroplasty requires bead-marking for radiographic visibility of the liner. However, occlusion of markers poses a challenge for marker registration in radiographs. Methods The polyethylene of a dual mobility acetabular system was marked with twelve 1-mm tantalum markers (four groups of three markers) using a custom-made drill guide. Liner motion in a phantom and a patient was investigated with dynamic radiostereometry analysis (dRSA) at 1-year follow-up and static radiostereometry analysis (sRSA) postoperatively and at 1- and 2-year follow-up. A combined marker configuration (CMC) model was calculated from the registered positions of the liner markers and the femoral head in several images. Furthermore, the CMC model and the theoretic marker positions from computer-assisted models of the drill guide were combined in a hybrid model. Results The CMC model included eleven markers in the phantom and nine markers in the patient, which was sufficient for dRSA. Liner movement in the phantom followed liner contact with the femoral neck, while liner movement in the patient was independent. The hybrid model was necessary to determine liner orientation in sRSA recordings, which clearly changed from postoperative to 1- and 2-year follow-up even though the patient was positioned similarly. Conclusion Polyethylene liner motion in dual mobility hip prosthesis can be assessed with CMC models in dRSA recordings. In sRSA, the liner position between follow-ups is unpredictable and analysis requires inclusion of all markers in the model, accomplished with a hybrid marker model. Trial registration ClinicalTrials.gov [NCT02301182], 25 October 2015. Supplementary Information The online version contains supplementary material available at 10.1186/s41747-021-00253-x.
Collapse
Affiliation(s)
- Peter Bo Jørgensen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark.
| | - Bart L Kaptein
- Department of Orthopaedics, Leiden University Medical Center, 2333, Leiden, ZA, The Netherlands
| | - Kjeld Søballe
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| | - Stig S Jakobsen
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| | - Maiken Stilling
- Department of Orthopaedics, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, J118-119, 8200, Aarhus, Denmark
| |
Collapse
|
4
|
Van de Kleut ML, Nair C, Milner JS, Holdsworth DW, Athwal GS, Teeter MG. In vivo reverse total shoulder arthroplasty contact mechanics. J Shoulder Elbow Surg 2021; 30:421-429. [PMID: 32580021 DOI: 10.1016/j.jse.2020.05.036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/19/2020] [Accepted: 05/24/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Several in vitro studies have investigated the biomechanics of reverse total shoulder arthroplasty (RTSA); however, few in vivo studies exist. The purpose of this study was to examine in vivo RTSA contact mechanics in clinically relevant arm positions. Our hypothesis was that contact would preferentially occur in the inferior region of the polyethylene liner. METHODS Forty patients receiving a primary RTSA were recruited for a prospective cohort study. All patients received the same implant design with a nonretentive liner. Stereo radiographs were taken at maximal active range of motion. Model-based radiostereometric analysis was used to identify implant position. Contact area between the polyethylene and glenosphere was measured as the geometric intersection of the 2 components and compared with respect to polyethylene liner size, arm position, and relative position within the liner. RESULTS There were no differences in the proportion of contact area in any arm position between polyethylene liner sizes, ranging from 30% ± 17% to 38% ± 23% for 36-mm liners and 32% ± 21% to 41% ± 25% for 42-mm liners. Contact was equally distributed between the superior and inferior halves of the liner at each arm position (P = .06-.79); however, greater contact area was observed in the outer radius of the liner when the arm was flexed (P = .002). CONCLUSION This study highlights that contact mechanics are similar between 36- and 42-mm liners. Contact area is generally equally distributed throughout the liner across the range of motion and not preferentially in the inferior region as hypothesized.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada; School of Biomedical Engineering, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada.
| | | | - Jaques S Milner
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada
| | - David W Holdsworth
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - George S Athwal
- Lawson Health Research Institute, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Center, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Roth
- McFarlane Hand and Upper Limb Center, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| |
Collapse
|
5
|
Abstract
BACKGROUND Revision of TKA as a result of polyethylene wear is decreasing, but long-term wear performance of polyethylene is still a topic of interest to surgeons and device manufacturers seeking to improve longevity. Measuring wear of modern, wear-resistant implants has been described using radiostereometric analysis (RSA). Performing in vivo measurements would establish whether implant retrieval studies are representative of wear in well-performing knees. QUESTIONS/PURPOSES For a single knee implant system, we sought to determine (1) the linear wear rate using RSA; (2) the association between demographic factors and wear rate; and (3) the association between limb alignment and wear rate. METHODS A total of 49 patients with a minimum followup of 10 years (median, 12 years; range, 10-20 years) were retrospectively selected. During the examined period, 4082 TKAs were performed of which 2085 were the implant examined in this study. There were 71 of these patients who met the criteria including an available full-leg radiograph postoperatively, and 34 of these patients returned for examination along with 15 additional from a separate RSA study that also met the criteria. All patients received a posterior-stabilized, cobalt-chromium-on-conventional polyethylene total knee implant from a single implant system, which was the most commonly used at our institution at the time. Patients underwent standing RSA examinations from 0° to 120° of flexion at a single time point without the use of marker beads. Linear wear rates (including creep) were measured based on intersections between the femoral component and tibial insert models. Associations between wear and patient age at surgery, sex, height, weight, body mass index, tibial insert size, and limb alignment were examined. RESULTS Using the maximum linear wear rate from any flexion angle, the lateral rate was 0.047 mm/year (interquartile range [IQR], 0.034-0.066 mm/year) and the medial rate was 0.052 mm/year (IQR, 0.040-0.069 mm/year). Using the median of the linear wear rates across all flexion angles, the lateral rate was 0.027 mm/year (IQR, 0.017-0.046 mm/year) and the medial rate was 0.038 mm/year (IQR, 0.022-0.054 mm/year). This rate for males was 0.049 mm/year medially (IQR, 0.042-0.077 mm/year) and 0.032 mm/year laterally (IQR, 0.026-0.059 mm/year), and for females was 0.027 mm/year medially (0.016-0.039 mm/year) and 0.020 mm/year laterally (IQR, 0.013-0.032 mm/year). The wear rate for males was greater medially (difference = 0.022 mm/year, p < 0.001) and laterally (difference = 0.012 mm/year, p = 0.008). There were associations between greater wear and increasing height (ρ = 0.48, p < 0.001 medially and ρ = 0.30, p = 0.04 laterally), decreasing body mass index (ρ = -0.31, p = 0.03 medially), and greater implant size (ρ = 0.34, p = 0.02 medially). Increasingly varus leg alignment was associated with greater medial wear (ρ = 0.33, p = 0.02). CONCLUSIONS Greater wear rates were associated with demographic factors and leg alignment. Further RSA wear studies of other modern implant systems would provide complementary information to retrieval studies and valuable data on wear resistance. CLINICAL RELEVANCE Good wear resistance was demonstrated by well-performing implants in patients at long-term followup with wear magnitudes in agreement with reported values from retrieval studies.
Collapse
|
6
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Additively manufactured implant components for imaging validation studies. Proc Inst Mech Eng H 2018; 232:690-698. [PMID: 29962327 DOI: 10.1177/0954411918784086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Radiographic imaging is the current standard for evaluating postoperative joint replacements. Prior to application, such imaging methods need to be validated to determine the lower limits of performance under ideal conditions, using either a phantom or cadaver setup. Conventionally manufactured orthopedic implants for use in such studies are not always accessible and may be cost-prohibitive to purchase. We propose the use of additively manufactured implants as a cheaper, more accessible alternative for use in radiographic imaging validation studies. Bias and repeatability were compared between conventionally manufactured and additively manufactured reverse total shoulder implant sets under a standard model-based radiostereometric analysis phantom study environment. Measurements were compared using the humeral stem or glenosphere model relative to reference bone beads, and the humeral stem relative to the glenosphere model to measure implant relative displacement. Compared to the conventionally manufactured implants, the additively manufactured implants had less bias along the internal-external rotation axis (p < 0.001), but greater bias along the abduction-adduction and flexion-extension rotation axes (p = 0.005, 0.011). Additively manufactured implants had greater repeatability along the internal-external rotation axis (p < 0.001), but worse repeatability along the medial-lateral translation axis (p = 0.001) and the abduction-adduction rotation axis (p < 0.001). Differences were on the orders of 0.01 mm and 0.5°. For the purpose of validating two-dimensional-three-dimensional radiographic imaging techniques of orthopedic implants, additively manufactured implants can be used in place of conventionally manufactured implants, assuming they are fabricated to the manufacturer's specifications. Observed differences were within the errors of the measurement technique and not clinically meaningful.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- 1 Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON, Canada.,2 Biomedical Engineering, Western University, London, ON, Canada.,3 Lawson Health Research Institute, London, ON, Canada
| | - Xunhua Yuan
- 1 Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON, Canada
| | - George S Athwal
- 3 Lawson Health Research Institute, London, ON, Canada.,4 Division of Orthopaedic Surgery, London Health Sciences Center, London, ON, Canada.,5 Department of Surgery, Western University, London, ON, Canada
| | - Matthew G Teeter
- 1 Imaging Research Laboratories, Robarts Research Institute, Western University, London, ON, Canada.,3 Lawson Health Research Institute, London, ON, Canada.,4 Division of Orthopaedic Surgery, London Health Sciences Center, London, ON, Canada.,5 Department of Surgery, Western University, London, ON, Canada.,6 Department of Medical Biophysics, Western University, London, ON, Canada
| |
Collapse
|
7
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Validation of radiostereometric analysis in six degrees of freedom for use with reverse total shoulder arthroplasty. J Biomech 2018; 68:126-131. [DOI: 10.1016/j.jbiomech.2017.12.027] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 12/11/2017] [Accepted: 12/17/2017] [Indexed: 11/15/2022]
|