• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4623024)   Today's Articles (55)   Subscriber (49407)
For: Peng Y, Arauz P, An S, Kwon YM. In vivo sliding distance on the metal-on-polyethylene total hip arthroplasty articulation using patient-specific gait analysis. J Orthop Res 2018;36:3151-3160. [PMID: 30035328 DOI: 10.1002/jor.24113] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 07/13/2018] [Indexed: 02/04/2023]
Number Cited by Other Article(s)
1
Wang W, Zhang Z, Wang G, Rong C, Xu H, Lu X, Liu Y, Li C, Zhang H. Prospective randomized controlled trial on the accuracy of prosthesis positioning in total hip arthroplasty assisted by a newly designed whole-process robotic arm. INTERNATIONAL ORTHOPAEDICS 2023;47:413-419. [PMID: 35802187 DOI: 10.1007/s00264-022-05501-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 06/23/2022] [Indexed: 01/28/2023]
2
Kumar A, Mondal S, Ghosh R. Biomechanical performance of the cemented acetabular cup with combined effects of bone quality, implant material combinations and bodyweight. Proc Inst Mech Eng H 2022;236:1309-1327. [DOI: 10.1177/09544119221113698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
3
Klemt C, Bounajem G, Tirumala V, Xiong L, Padmanabha A, Kwon YM. Three-dimensional kinematic analysis of dislocation mechanism in dual mobility total hip arthroplasty constructs. J Orthop Res 2021;39:1423-1432. [PMID: 32915465 DOI: 10.1002/jor.24855] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 08/25/2020] [Accepted: 09/08/2020] [Indexed: 02/04/2023]
4
The impact of polyethylene abrasion on the occurrence of periprosthetic proximal femoral fractures in patients with total hip arthroplasty. Eur J Trauma Emerg Surg 2019;47:211-216. [PMID: 31520158 DOI: 10.1007/s00068-019-01222-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2019] [Accepted: 08/26/2019] [Indexed: 10/26/2022]
5
Kaku N, Tagomori H, Akase H, Tabata T, Kataoka M, Tsumura H. Efficacy of vitamin E for mechanical damage and oxidation of polyethylene rim by stem neck impingement. Clin Biomech (Bristol, Avon) 2019;68:8-15. [PMID: 31128555 DOI: 10.1016/j.clinbiomech.2019.05.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 04/25/2019] [Accepted: 05/15/2019] [Indexed: 02/07/2023]
6
Limmahakhun S, Box HN, Arauz P, Hennessy DW, Klemt C, Kwon YM. In Vivo analysis of spinopelvic kinematics and peak head-cup contact in total hip arthroplasty patients with lumbar degenerative disc disease. J Orthop Res 2019;37:674-680. [PMID: 30690800 DOI: 10.1002/jor.24234] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 01/21/2019] [Indexed: 02/04/2023]
PrevPage 1 of 1 1Next