Labus KM, Wolynski J, Easley J, Stewart HL, Ilic M, Notaros B, Zagrocki T, Puttlitz CM, McGilvray KC. Employing direct electromagnetic coupling to assess acute fracture healing: An ovine model assessment. Injury 2023; 54:111080. [PMID: 37802738 PMCID: PMC10843464 DOI: 10.1016/j.injury.2023.111080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/13/2023] [Accepted: 09/26/2023] [Indexed: 10/08/2023]
Abstract
OBJECTIVES This study explored the efficacy of collecting temporal fracture site compliance data via an advanced direct electromagnetic coupling (DEC) system equipped with a Vivaldi-type antenna, novel calibration technique, and multi-antenna setup (termed maDEC) as an approach to monitor acute fracture healing progress in a translational large animal model. The overarching goal of this approach was to provide insights into the acute healing dynamics, offering a promising avenue for optimizing fracture management strategies. METHODS A sample of twelve sheep, subjected to ostectomies and intramedullary nail fixations, was divided into two groups, simulating normal and impaired healing scenarios. Sequential maDEC compliance or stiffness measurements and radiographs were taken from the surgery until euthanasia at four or eight weeks and were subsequently compared with post-sacrifice biomechanical, micro-CT, and histological findings. RESULTS The results showed that the maDEC system offered straightforward quantification of fracture site compliance via a multiantenna array. Notably, the rate of change in the maDEC-measured bending stiffness significantly varied between normal and impaired healing groups during both the 4-week (p = 0.04) and 8-week (p = 0.02) periods. In contrast, radiographically derived mRUST healing measurements displayed no significant differences between the groups (p = 0.46). Moreover, the cumulative normalized stiffness maDEC data significantly correlated with post-sacrifice mechanical strength (r2 = 0.80, p < 0.001), micro-CT measurements of bone volume fraction (r2 = 0.60, p = 0.003), and density (r2 = 0.60, p = 0.003), and histomorphometric measurements of new bone area fraction (r2 = 0.61, p = 0.003) and new bone area (r2 = 0.60, p < 0.001). CONCLUSIONS These data indicate that the enhanced maDEC system provides a non-invasive, accurate method to monitor fracture healing during the acute healing phase, showing distinct stiffness profiles between normal and impaired healing groups and offering critical insights into the healing process's progress and efficiency.
Collapse
Affiliation(s)
- Kevin M Labus
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Jakob Wolynski
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Jeremiah Easley
- Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Holly L Stewart
- Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, Colorado, USA
| | - Milan Ilic
- University of Belgrade, School of Electrical Engineering, Belgrade, Serbia
| | - Branislav Notaros
- Electromagnetic Laboratory, Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, Colorado, USA
| | - Taylor Zagrocki
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Christian M Puttlitz
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Kirk C McGilvray
- Orthopaedic Bioengineering Research Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
2
|
Conceição C, Completo A, Soares dos Santos MP. Ultrasensitive capacitive sensing system for smart medical devices with ability to monitor fracture healing stages. J R Soc Interface 2023; 20:20220818. [PMCID: PMC9943881 DOI: 10.1098/rsif.2022.0818] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023] Open
Abstract
Bone fractures are a global public health problem. A sustained increase in the number of incident cases has been observed in the last few decades, as well as the number of prevalent cases and the number of years lived with disability. Current monitoring techniques are based on imaging techniques, which are highly subjective, radioactive, expensive and unable to provide daily monitoring of fracture healing stages. The development of reliable, non-invasive and non-subjective technologies is mandatory to minimize non-union risks. Delayed healing and non-union conditions require timely medical intervention, such that preventive procedures and shortened treatment periods can be carried out. This work proposes the development of an ultrasensitive capacitive sensing system for smart implantable fixation implants with ability to effectively monitor the evolution of bone fractures. Both in vitro experimental tests and numerical simulations highlight that networks of co-surface capacitive systems are able: (i) to detect four different bone healing phases, capacitance decrease patterns occurring as the healing process progresses and (ii) to monitor the callus evolution in multiple target regions. These are very promising results that highlight the potential of capacitive technologies to minimize the individual and social burdens related to fracture management, mainly when delayed healing or non-union conditions occur.
Collapse
Affiliation(s)
- Cassandra Conceição
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal
| | - António Completo
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal,TEMA—Centre for Mechanical Technology and Automation, 3810-193 Aveiro, Portugal,LASI—Intelligent Systems Associate Laboratory, Portugal
| | - Marco P. Soares dos Santos
- Department of Mechanical Engineering, University of Aveiro, 3810-193 Aveiro, Portugal,TEMA—Centre for Mechanical Technology and Automation, 3810-193 Aveiro, Portugal,LASI—Intelligent Systems Associate Laboratory, Portugal
| |
Collapse
|
3
|
Correlation of Bone Strength in an Animal Model (Rabbit) After Fracture and During the Period of Fixation with a Titanium Micro Plate. ACTA VET-BEOGRAD 2022. [DOI: 10.2478/acve-2022-0036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Abstract
The period of bone healing after trauma goes through certain physiological processes. In situations where a bone fracture occurs, our intention is to surgically position in an appropriate morpho-anatomical position. For osteosynthesis we used vipla wire and micro plates with corresponding screws.
The aim of our research was to evaluate the optimal time for the removal of the osteosynthetic material, fracture site biomechanical stability, and measurement of the callus thickness.
For this research ten 4 months old rabbits with right leg femur fracture were used. Osteosynthesis was done with titanium micro plates, corresponding screws and vipla wire. Experimental animals were observed through the post-operative period at the first and seventh postoperative day and there on at 2, 4, 6, 9, 12 weeks. Further additional fixation was needed in one of the rabbits in the second week.
The postoperative period provided us information about the optimal moment for the removal of titanium micro plates. It showed that over a period of six weeks, the bone had almost all normal biomechanical properties. Significantly greater strength and rigidity of the recovered femur were obtained after 12 weeks. Micro plates that were removed after 4, 6 or 9 weeks, did not need furhter fixation and therefore fixation was not applied, compared to those placed during the 12 weeks. X Ray evaluation provided us with follow up results of fracture healing.
The results suggest that it is acceptable to remove titanium micro plates after a period of healing, that is, after the formation of the callus and bridging of the fracture gap and diastasis with newly formed bone.
Collapse
|
4
|
Altering the course of fracture healing monitoring. BIOMEDICAL ENGINEERING ADVANCES 2022. [DOI: 10.1016/j.bea.2022.100068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
|
5
|
Windolf M, Varjas V, Gehweiler D, Schwyn R, Arens D, Constant C, Zeiter S, Richards RG, Ernst M. Continuous Implant Load Monitoring to Assess Bone Healing Status—Evidence from Animal Testing. Medicina (B Aires) 2022; 58:medicina58070858. [PMID: 35888576 PMCID: PMC9321316 DOI: 10.3390/medicina58070858] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 06/20/2022] [Accepted: 06/21/2022] [Indexed: 12/02/2022] Open
Abstract
Background and Objectives: Fracture healing is currently assessed through qualitative evaluation of radiographic images, which is highly subjective in nature. Radiographs can only provide snapshots in time, which are limited due to logistics and radiation exposure. We recently proposed assessing the bone healing status through continuous monitoring of the implant load, utilizing an implanted sensor system, the Fracture Monitor. The device telemetrically transmits statistically derived implant parameters via the patient’s mobile phone to assist physicians in diagnostics and treatment decision-making. This preclinical study aims to systematically investigate the device safety and performance in an animal setting. Materials and Methods: Mid-shaft tibial osteotomies of different sizes (0.6–30 mm) were created in eleven Swiss mountain sheep. The bones were stabilized with either a conventional Titanium or stainless-steel locking plate equipped with a Fracture Monitor. Data were continuously collected over the device’s lifetime. Conventional radiographs and clinical CT scans were taken longitudinally over the study period. The radiographs were systematically scored and CTs were evaluated for normalized bone volume in the defect. The animals were euthanized after 9 months. The sensor output was correlated with the radiologic parameters. Tissue samples from the device location were histologically examined. Results: The sensors functioned autonomously for 6.5–8.4 months until energy depletion. No macroscopic or microscopic adverse effects from device implantation were observed. The relative implant loads at 4 and 8 weeks post-operation correlated significantly with the radiographic scores and with the normalized bone volume metric. Conclusions: Continuous implant load monitoring appears as a relevant approach to support and objectify fracture healing assessments and carries a strong potential to enable patient-tailored rehabilitation in the future.
Collapse
|
6
|
Wolynski JG, Ilić MM, Notaroš BM, Labus KM, Puttlitz CM, McGilvray KC. Vivaldi Antennas for Contactless Sensing of Implant Deflections and Stiffness for Orthopaedic Applications. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2021; 10:1151-1161. [PMID: 35873899 PMCID: PMC9307137 DOI: 10.1109/access.2021.3137718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The implementation of novel coaxial dipole antennas has been shown to be a satisfactory diagnostic platform for the prediction of orthopaedic bone fracture healing outcomes. These techniques require mechanical deflection of implanted metallic hardware (i.e., rods and plates), which, when loaded, produce measurable changes in the resonant frequency of the adjacent antenna. Despite promising initial results, the coiled coaxial antenna design is limited by large antenna sizes and nonlinearity in the resonant frequency data. The purpose of this study was to develop two Vivaldi antennas (a.k.a., "standard" and "miniaturized") to address these challenges. Antenna behaviors were first computationally modeled prior to prototype fabrication. In subsequent benchtop tests, metallic plate segments were displaced from the prototype antennas via precision linear actuator while measuring resultant change in resonant frequency. Close agreement was observed between computational and benchtop results, where antennas were highly sensitive to small displacements of the metallic hardware, with sensitivity decreasing nonlinearly with increasing distance. Greater sensitivity was observed for the miniaturized design for both stainless steel and titanium implants. Additionally, these data demonstrated that by taking resonant frequency data during implant displacement and then again during antenna displacement from the same sample, via linear actuators, that "antenna calibration procedures" could be used to enable a clinically relevant quantification of fracture stiffness from the raw resonant frequency data. These improvements mitigate diagnostic challenges associated with nonlinear resonant frequency response seen in previous antenna designs.
Collapse
Affiliation(s)
- Jakob G Wolynski
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Milan M Ilić
- School of Electrical Engineering, University of Belgrade, 11120 Belgrade, Serbia
| | - Branislav M Notaroš
- Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Kevin M Labus
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Christian M Puttlitz
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | - Kirk C McGilvray
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| |
Collapse
|
7
|
Wolynski JG, Labus KM, Easley JT, Notaroš BM, Ilić MM, Puttlitz CM, McGilvray KC. Diagnostic prediction of ovine fracture healing outcomes via a novel multi-location direct electromagnetic coupling antenna. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1223. [PMID: 34532360 PMCID: PMC8421979 DOI: 10.21037/atm-21-1853] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/23/2021] [Indexed: 01/15/2023]
Abstract
Background Expedient prediction of adverse bone fracture healing (delayed- or non-union) is necessary to advise secondary treatments for improving healing outcome to minimize patient suffering. Radiographic imaging, the current standard diagnostic, remains largely ineffective at predicting nonunions during the early stages of fracture healing resulting in mean nonunion diagnosis times exceeding six months. Thus, there remains a clinical deficit necessitating improved diagnostic techniques. It was hypothesized that adverse fracture healing expresses impaired biological progression at the fracture site, thus resulting in reduced temporal progression of fracture site stiffness which may be quantified prior to the appearance of radiographic indicators of fracture healing (i.e., calcified tissue). Methods A novel multi-location direct electromagnetic coupling antenna was developed to diagnose relative changes in the stiffness of fractures treated by metallic orthopaedic hardware. The efficacy of this diagnostic was evaluated during fracture healing simulated by progressive destabilization of cadaveric ovine metatarsals treated by locking plate fixation (n=8). An ovine in vivo comparative fracture study (n=8) was then utilized to better characterize the performance of the developed diagnostic in a clinically translatable setting. In vivo measurements using the developed diagnostic were compared to weekly radiographic images and postmortem biomechanical, histological, and micro computed tomography analyses. Results For all cadaveric samples, the novel direct electromagnetic coupling antenna displayed significant differences at the fracture site (P<0.05) when measuring a fully fractured sample versus partially intact and fully intact fracture states. In subsequent in vivo fracture models, this technology detected significant differences (P<0.001) in fractures trending towards delayed healing during the first 30 days post-fracture. Conclusions This technology, relative to traditional X-ray imaging, exhibits potential to greatly expedite clinical diagnosis of fracture nonunion, thus warranting additional technological development.
Collapse
Affiliation(s)
- Jakob G Wolynski
- Orthopaedic Bioengineering Research Laboratory, Departments of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Kevin M Labus
- Orthopaedic Bioengineering Research Laboratory, Departments of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Jeremiah T Easley
- Preclinical Surgical Research Laboratory, Department of Clinical Sciences, Colorado State University, Fort Collins, CO, USA
| | - Branislav M Notaroš
- Department of Electrical and Computer Engineering, Colorado State University, Fort Collins, CO, USA
| | - Milan M Ilić
- School of Electrical Engineering, University of Belgrade, Belgrade, Serbia
| | - Christian M Puttlitz
- Orthopaedic Bioengineering Research Laboratory, Departments of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Kirk C McGilvray
- Orthopaedic Bioengineering Research Laboratory, Departments of Mechanical Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| |
Collapse
|