1
|
Gibon E, Takakubo Y, Zwingenberger S, Gallo J, Takagi M, Goodman SB. Friend or foe? Inflammation and the foreign body response to orthopedic biomaterials. J Biomed Mater Res A 2024; 112:1172-1187. [PMID: 37656958 DOI: 10.1002/jbm.a.37599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 08/03/2023] [Accepted: 08/14/2023] [Indexed: 09/03/2023]
Abstract
The use of biomaterials and implants for joint replacement, fracture fixation, spinal stabilization and other orthopedic indications has revolutionized patient care by reliably decreasing pain and improving function. These surgical procedures always invoke an acute inflammatory reaction initially, that in most cases, readily subsides. Occasionally, chronic inflammation around the implant develops and persists; this results in unremitting pain and compromises function. The etiology of chronic inflammation may be specific, such as with infection, or be unknown. The histological hallmarks of chronic inflammation include activated macrophages, fibroblasts, T cell subsets, and other cells of the innate immune system. The presence of cells of the adaptive immune system usually indicates allergic reactions to metallic haptens. A foreign body reaction is composed of activated macrophages, giant cells, fibroblasts, and other cells often distributed in a characteristic histological arrangement; this reaction is usually due to particulate debris and other byproducts from the biomaterials used in the implant. Both chronic inflammation and the foreign body response have adverse biological effects on the integration of the implant with the surrounding tissues. Strategies to mitigate chronic inflammation and the foreign body response will enhance the initial incorporation and longevity of the implant, and thereby, improve long-term pain relief and overall function for the patient. The seminal research performed in the laboratory of Dr. James Anderson and co-workers has provided an inspirational and driving force for our laboratory's work on the interactions and crosstalk among cells of the mesenchymal, immune, and vascular lineages, and orthopedic biomaterials. Dr. Anderson's delineation of the fundamental biologic processes and mechanisms underlying acute and chronic inflammation, the foreign body response, resolution, and eventual functional integration of implants in different organ systems has provided researchers with a strategic approach to the use of biomaterials to improve health in numerous clinical scenarios.
Collapse
Affiliation(s)
- Emmanuel Gibon
- Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yuya Takakubo
- Department of Rehabilitation, Yamagata University, Faculty of Medicine, Yamagata, Japan
| | - Stefan Zwingenberger
- University Center for Orthopaedics, Traumatology, and Plastic Surgery, University Hospital Carl Gustav Carus at Technische Universität Dresden, Dresden, Germany
| | - Jiri Gallo
- Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc Teaching Hospital, Olomouc, Czech Republic
| | - Michiaki Takagi
- Department of Orthopaedic Surgery, Yamagata University Faculty of Medicine, Yamagata, Japan
| | - Stuart B Goodman
- Department of Orthopaedic Surgery and (by courtesy) Bioengineering, Stanford University Medical Center Outpatient Center, California, USA
| |
Collapse
|
2
|
Mann KA, Miller MA, Gandhi SA, Kusler JE, Tatusko ME, Biggs AE, Oest ME. Peri-operative zoledronic acid attenuates peri-prosthetic osteolysis in a rat model of cemented knee replacement. J Orthop Res 2024. [PMID: 39032112 DOI: 10.1002/jor.25941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/23/2024] [Accepted: 06/28/2024] [Indexed: 07/22/2024]
Abstract
Progressive osteolysis can occur at the cement-bone interface of joint replacements and the associated loss of fixation can lead to clinical loosening. We previously developed a rat hemiarthroplasty model that exhibited progressive loss of fixation with the development of cement-bone gaps under the tibial tray that mimicked patterns found in human arthroplasty retrievals. Here we explored the ability of a bisphosphonate (zoledronic acid, ZA) to attenuate cement-bone osteolysis and maintain implant stability. Sprague-Dawley rats (n = 59) received a poly(methylmethacrylate) cemented tibial component and were followed for up to 12 weeks. Treatment groups included peri-operative administration of ZA (ZA group), administration of ZA at 6 weeks postop (late ZA group), or vehicle (Veh group). There was a 60% reduction in the rate of cement-bone gap formation for the ZA group (0.15 mm3/week) compared to Veh group (0.38 mm3/week, p = 0.016). Late ZA prevented further progression of gap formation but did not reverse bone loss to the level achieved in the ZA group. Micromotion from five times body weight toggle loading was positively correlated with cement-bone gap volume (p = 0.009) and negatively correlated with the amount of cement in the metaphysis (p = 0.005). Reduced new bone formation and enduring nonviable bone in the epiphysis for the ZA group were found. This suggests that low bone turnover in the epiphysis may suppress the early catabolic response due to implantation, thereby maintaining better fixation in the epiphysis. This preclinical model presents compelling supporting data documenting improved maintenance of the cement-bone fixation with the use of peri-operative bisphosphonates.
Collapse
Affiliation(s)
- Kenneth A Mann
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Mark A Miller
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Sachin A Gandhi
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Jace E Kusler
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Megan E Tatusko
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Amy E Biggs
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| | - Megan E Oest
- Department of Orthopedic Surgery, Institute for Human Performance, SUNY Upstate Medical University, Syracuse, New York, USA
| |
Collapse
|
3
|
V B, Magesh V, Harikrishnan P. Effect of cortical bone thickness on shear stress and force in orthodontic miniscrew-bone interface - A finite element analysis. Biomed Phys Eng Express 2024; 10:055013. [PMID: 38986445 DOI: 10.1088/2057-1976/ad6160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 07/10/2024] [Indexed: 07/12/2024]
Abstract
Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09CBT) and 2.66 mm (2.66CBT) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09CBTand 2.66CBTcompared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.
Collapse
Affiliation(s)
- Balamurali V
- Department of Mechanical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Chennai - 603203, Tamil Nadu, India
| | - Varadaraju Magesh
- Department of Mechanical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur, Chennai - 603203, Tamil Nadu, India
| | - Pandurangan Harikrishnan
- Craniofacial Orthodontist and Oral Surgeon, Teeth 'N' Jaws Center, No. 23 & 25, 1st Cross Street, Lake Area, Nungambakkam, Chennai - 600034, Tamil Nadu, India
| |
Collapse
|
4
|
Bratengeier C, Johansson L, Liszka A, Bakker AD, Hallbeck M, Fahlgren A. Mechanical loading intensities affect the release of extracellular vesicles from mouse bone marrow-derived hematopoietic progenitor cells and change their osteoclast-modulating effect. FASEB J 2024; 38:e23323. [PMID: 38015031 DOI: 10.1096/fj.202301520r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 10/19/2023] [Accepted: 11/07/2023] [Indexed: 11/29/2023]
Abstract
Low-intensity loading maintains or increases bone mass, whereas lack of mechanical loading and high-intensity loading decreases bone mass, possibly via the release of extracellular vesicles by mechanosensitive bone cells. How different loading intensities alter the biological effect of these vesicles is not fully understood. Dynamic fluid shear stress at low intensity (0.7 ± 0.3 Pa, 5 Hz) or high intensity (2.9 ± 0.2 Pa, 1 Hz) was used on mouse hematopoietic progenitor cells for 2 min in the presence or absence of chemical compounds that inhibit release or biogenesis of extracellular vesicles. We used a Receptor activator of nuclear factor kappa-Β ligand-induced osteoclastogenesis assay to evaluate the biological effect of different fractions of extracellular vesicles obtained through centrifugation of medium from hematopoietic stem cells. Osteoclast formation was reduced by microvesicles (10 000× g) obtained after low-intensity loading and induced by exosomes (100 000× g) obtained after high-intensity loading. These osteoclast-modulating effects could be diminished or eliminated by depletion of extracellular vesicles from the conditioned medium, inhibition of general extracellular vesicle release, inhibition of microvesicle biogenesis (low intensity), inhibition of ESCRT-independent exosome biogenesis (high intensity), as well as by inhibition of dynamin-dependent vesicle uptake in osteoclast progenitor cells. Taken together, the intensity of mechanical loading affects the release of extracellular vesicles and change their osteoclast-modulating effect.
Collapse
Affiliation(s)
- C Bratengeier
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - L Johansson
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
- Department of Clinical Pathology, Linköping University, Linköping, Sweden
| | - A Liszka
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| | - A D Bakker
- Department of Oral Cell Biology, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, The Netherlands
| | - M Hallbeck
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
- Department of Clinical Pathology, Linköping University, Linköping, Sweden
| | - A Fahlgren
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
5
|
Panez-Toro I, Heymann D, Gouin F, Amiaud J, Heymann MF, Córdova LA. Roles of inflammatory cell infiltrate in periprosthetic osteolysis. Front Immunol 2023; 14:1310262. [PMID: 38106424 PMCID: PMC10722268 DOI: 10.3389/fimmu.2023.1310262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/13/2023] [Indexed: 12/19/2023] Open
Abstract
Classically, particle-induced periprosthetic osteolysis at the implant-bone interface has explained the aseptic loosening of joint replacement. This response is preceded by triggering both the innate and acquired immune response with subsequent activation of osteoclasts, the bone-resorbing cells. Although particle-induced periprosthetic osteolysis has been considered a foreign body chronic inflammation mediated by myelomonocytic-derived cells, current reports describe wide heterogeneous inflammatory cells infiltrating the periprosthetic tissues. This review aims to discuss the role of those non-myelomonocytic cells in periprosthetic tissues exposed to wear particles by showing original data. Specifically, we discuss the role of T cells (CD3+, CD4+, and CD8+) and B cells (CD20+) coexisting with CD68+/TRAP- multinucleated giant cells associated with both polyethylene and metallic particles infiltrating retrieved periprosthetic membranes. This review contributes valuable insight to support the complex cell and molecular mechanisms behind the aseptic loosening theories of orthopedic implants.
Collapse
Affiliation(s)
- Isidora Panez-Toro
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Dominique Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
- The University of Sheffield, Dept of Oncology and Metabolism, Sheffield, United Kingdom
| | - François Gouin
- Department of Surgical Oncology, Centre Léon Bérard, Lyon, France
| | - Jérôme Amiaud
- Nantes Université, Laboratory of Histology and Embryology, Medical School, Nantes, France
| | - Marie-Françoise Heymann
- Nantes Université, Centre National de Recherche Scientifique (CNRS), UMR6286, US2B, Nantes, France
- Institut de Cancérologie de l’Ouest, Tumor Heterogeneity and Precision Medicine Laboratory, Saint-Herblain, France
| | - Luis A. Córdova
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, University of Chile, Independencia, Santiago, Chile
- IMPACT, Center of Interventional Medicine for Precision and Advanced Cellular Therapy, Santiago, Chile
- Oral and Maxillofacial Surgery, Clínica MEDS, Santiago, Chile
| |
Collapse
|