1
|
Ingle I, Kerns JG, Shepherd RF. Multivariate analysis of Raman spectra for discriminating human collagens: In vitro identification of extracellular matrix collagens produced by an osteosarcoma cell line. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 328:125434. [PMID: 39612534 DOI: 10.1016/j.saa.2024.125434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 10/11/2024] [Accepted: 11/10/2024] [Indexed: 12/01/2024]
Abstract
BACKGROUND The NHS spends £4.3 billion annually to address musculoskeletal conditions, encompassing age-related bone disorders like osteoarthritis and osteoporosis. Traditional X-ray diagnostic methods are commonly employed for bone disorder diagnosis, primarily assessing gross anatomical bone structure changes. However, these methods are unable to identify subtle biochemical alterations within the bone. More detailed information, particularly about protein changes, may lead to enhanced diagnostics and treatment. Raman spectroscopy is a non-invasive, laser-based technique capable of detecting changes in the collagen component of bone. Despite its long-standing application in discerning mineral and protein changes within bone, there is limited evidence on Raman spectral signatures of purified human collagens and their differentiation. This study aimed to test the hypothesis that Raman spectroscopy could detect different types of collagen in the human body. RESULTS A Raman microspectrometer with a 785 nm laser was used to measure unmineralized human collagens types I - VI and collagenous extracellular matrix (ECM) secreted by MG63 osteoblast-like cells. The results demonstrated the efficacy of Raman spectroscopy and subsequent multivariate analysis in distinguishing human collagen types I - VI. This implies that Raman spectroscopy, coupled with multivariate analysis, can identify pure human collagens and offers reference spectra similar to natural human collagen in the bone extracellular matrix. SIGNIFICANCE This study establishes Raman spectroscopy as a tool for identifying and characterizing human collagens, aiding in the diagnosis of connective tissue disorders. The creation of a spectral reference library for pure human collagen types I - VI holds potential for medical diagnostics, analytical chemistry, and materials science applications.
Collapse
Affiliation(s)
- Iona Ingle
- Lancaster Medical School, Lancaster University, LA1 4AT, United Kingdom
| | - Jemma G Kerns
- Lancaster Medical School, Lancaster University, LA1 4AT, United Kingdom
| | - Rebecca F Shepherd
- Lancaster Medical School, Lancaster University, LA1 4AT, United Kingdom; Bristol School of Anatomy, Bristol University, BS2 8EJ, United Kingdom.
| |
Collapse
|
2
|
Unal S, Mayda M, Nyman JS, Unal M. Optimizing number of Raman spectra using an artificial neural network guided Monte Carlo simulation approach to analyze human cortical bone. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 325:125035. [PMID: 39217957 PMCID: PMC11560527 DOI: 10.1016/j.saa.2024.125035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2024] [Revised: 08/06/2024] [Accepted: 08/22/2024] [Indexed: 09/04/2024]
Abstract
This study presents a novel methodology for optimizing the number of Raman spectra required per sample for human bone compositional analysis. The methodology integrates Artificial Neural Network (ANN) and Monte Carlo Simulation (MCS). We demonstrate the robustness of ANN in enabling prediction of Raman spectroscopy-based bone quality properties even with limited spectral inputs. The ANN algorithms tailored to individual sex and age groups, which enhance the specificity and accuracy of predictions in bone quality properties. In addition, ANN guided MCS systematically explores the variability and uncertainty inherent in different sample sizes and spectral datasets, leading to the identification of an optimal number of spectra per sample for characterizing human bone tissues. The findings suggest that as low as 2 spectra are sufficient for biochemical analysis of bone, with R2 values between real and predicted values of v1/PO4/Amide I and ∼I1670/I1640 ratios, ranging from 0.60 to 0.89. Our results also suggest that up to 8 spectra could be optimal when balancing other factors. This optimized approach streamlines experimental workflows, reduces data and acquisition costs. Additionally, our study highlights the potential for advancing Raman spectroscopy in bone research through the innovative integration of ANN-guided probabilistic modeling techniques. This research could significantly contribute to the broader landscape of bone quality analyses by establishing a precedent for optimizing the number of Raman spectra with sophisticated computational tools. It also sets a novel platform for future optimization studies in Raman spectroscopy applications in biomedical field.
Collapse
Affiliation(s)
- Safa Unal
- Department of Mechanical Engineering, Karamanoglu Mehmetbey University, Karaman 70200, Turkey
| | - Murat Mayda
- Department of Mechanical Engineering, Karamanoglu Mehmetbey University, Karaman 70200, Turkey
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA; Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; United States Department of Veterans Affairs, Tennessee Valley Healthcare System, 1310 24(th) Ave. S., Nashville, TN 37212, USA
| | - Mustafa Unal
- Department of Mechanical Engineering, Karamanoglu Mehmetbey University, Karaman 70200, Turkey; Department of Bioengineering, Karamanoglu Mehmetbey University, Karaman 70200, Turkey; Faculty of Medicine, Department of Biophysics, Karamanoglu Mehmetbey University, Karaman 70200, Turkey; Department of Orthopedic Surgery, Harvard Medical School, Boston, MA 020115, USA; The Center for Advanced Orthopedic Studies, BIDMC, Boston, MA 020115, USA.
| |
Collapse
|
3
|
Chen K, Sun M, Chen S. Determining ideal offsets of spatially offset Raman spectroscopy for transcutaneous measurements-A Monte Carlo study. JOURNAL OF BIOPHOTONICS 2024; 17:e202300564. [PMID: 38887978 DOI: 10.1002/jbio.202300564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 03/09/2024] [Accepted: 04/25/2024] [Indexed: 06/20/2024]
Abstract
Spatially offset Raman spectroscopy (SORS) is valuable for noninvasive bone assessment but requires a clearer understanding of how offset distances influence detection depth. To address this, our study devised a forward-adjoint Monte Carlo multi-layer (MCML) model to simulate photon paths in SORS, aiming to determine optimal offsets for various tissue types. We examined photon migration at offsets between 0 and 15 mm against layered phantoms of differing thicknesses and compositions to optimize the signal-to-noise ratio for bone layers. The findings highlight that optimal offsets are contingent on tissue characteristics: a metacarpal beneath 2.5 mm of tissue had an ideal offset of 6.7 mm, while a tibia with 5 mm of soft tissue required 10-11 mm. This precise calibration of SORS via MCML modeling promises substantial improvements in bone health diagnostics and potential for expansive medical applications.
Collapse
Affiliation(s)
- Keren Chen
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China
- Foshan Graduate School of Innovation, Northeastern University, Foshan, China
| | - Mengya Sun
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China
- Foshan Graduate School of Innovation, Northeastern University, Foshan, China
| | - Shuo Chen
- College of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, China
| |
Collapse
|
4
|
Stanek E, Majka Z, Czamara K, Mazurkiewicz J, Kaczor A. Spatially Offset Raman Spectroscopy toward In Vivo Assessment of the Adipose Tissue in Cardiometabolic Pathologies. Anal Chem 2024; 96:10373-10379. [PMID: 38865715 PMCID: PMC11209658 DOI: 10.1021/acs.analchem.4c01477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/24/2024] [Accepted: 05/31/2024] [Indexed: 06/14/2024]
Abstract
Spatially offset Raman spectroscopy (SORS) enhanced the capabilities of Raman spectroscopy for the depth-resolved analysis of biological and diffusely scattering samples. This technique offers selective probing of subsurface layers, providing molecular insights without invasive procedures. While SORS has found application in biomedical research, up to now, studies have focused mainly on the detection of mineralization of bones and tissues. Herein, for the first time, SORS is used to assess the soft, organic tissue beneath the skin's surface. In this study, we demonstrate the diagnostic utility of a hand-held SORS device for evaluating the chemical composition of the adipose tissue. We compared perigonadal white adipose tissue (gWAT) in a murine model of atherosclerosis, heart failure, and high-fat diet (HFD) induced obesity. Our results reveal distinct chemical differences in gWAT between HFD-fed and control mice, showcasing the potential of SORS for intravital adipose tissue phenotype characterization. Furthermore, our findings underscore the effectiveness of SORS as a valuable tool for noninvasive assessment of the adipose tissue composition, holding potential diagnostic significance for metabolic disorders.
Collapse
Affiliation(s)
- Ewa Stanek
- Doctoral
School of Exact and Natural Sciences, Jagiellonian
University, 11 Lojasiewicza Str., 30-348 Krakow, Poland
- Jagiellonian
Centre for Experimental Therapeutics (JCET), Jagiellonian University, 14 Bobrzynskiego Str., 30-348 Krakow, Poland
| | - Zuzanna Majka
- Jagiellonian
Centre for Experimental Therapeutics (JCET), Jagiellonian University, 14 Bobrzynskiego Str., 30-348 Krakow, Poland
- Faculty
of Chemistry, Jagiellonian University, 2 Gronostajowa Str., 30-387 Krakow, Poland
| | - Krzysztof Czamara
- Jagiellonian
Centre for Experimental Therapeutics (JCET), Jagiellonian University, 14 Bobrzynskiego Str., 30-348 Krakow, Poland
| | - Joanna Mazurkiewicz
- Doctoral
School of Exact and Natural Sciences, Jagiellonian
University, 11 Lojasiewicza Str., 30-348 Krakow, Poland
- Faculty
of Chemistry, Jagiellonian University, 2 Gronostajowa Str., 30-387 Krakow, Poland
| | - Agnieszka Kaczor
- Faculty
of Chemistry, Jagiellonian University, 2 Gronostajowa Str., 30-387 Krakow, Poland
| |
Collapse
|
5
|
Surowiec RK, Does MD, Nyman JS. In Vivo Assessment of Bone Quality Without X-rays. Curr Osteoporos Rep 2024; 22:56-68. [PMID: 38227178 PMCID: PMC11050740 DOI: 10.1007/s11914-023-00856-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/22/2023] [Indexed: 01/17/2024]
Abstract
PURPOSE OF REVIEW This review summarizes recent advances in the assessment of bone quality using non-X-ray techniques. RECENT FINDINGS Quantitative ultrasound (QUS) provides multiple measurements of bone characteristics based on the propagation of sound through bone, the attenuation of that sound, and different processing techniques. QUS parameters and model predictions based on backscattered signals can discriminate non-fracture from fracture cases with accuracy comparable to standard bone mineral density (BMD). With advances in magnetic resonance imaging (MRI), bound water and pore water, or a porosity index, can be quantified in several long bones in vivo. Since such imaging-derived measurements correlate with the fracture resistance of bone, they potentially provide new BMD-independent predictors of fracture risk. While numerous measurements of mineral, organic matrix, and bound water by Raman spectroscopy correlate with the strength and toughness of cortical bone, the clinical assessment of person's bone quality using spatially offset Raman spectroscopy (SORS) requires advanced spectral processing techniques that minimize contaminating signals from fat, skin, and blood. Limiting exposure of patients to ionizing radiation, QUS, MRI, and SORS has the potential to improve the assessment of fracture risk and track changes of new therapies that target bone matrix and micro-structure.
Collapse
Affiliation(s)
- Rachel K Surowiec
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Dr., West Lafayette, IN, 47907, USA
- Department of Radiology and Imaging Sciences, Indiana University School of Medicine, 550 N. University Blvd., Indianapolis, IN, 46202, USA
| | - Mark D Does
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA
- Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, 1161 21st Ave. S., Nashville, TN, 37232, USA
- Department of Electrical Engineering and Computer Science, Vanderbilt University, 400 24th Ave. S., Nashville, TN, 37212, USA
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN, 37232, USA.
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN, 37232, USA.
- Vanderbilt Center for Bone Biology, Vanderbilt University Medical Center, 1211 Medical Center Dr., Nashville, TN, 37212, USA.
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37212, USA.
| |
Collapse
|
6
|
Gautam R, Ahmed R, Haugen E, Unal M, Fitzgerald S, Uppuganti S, Mahadevan-Jansen A, Nyman JS. Assessment of spatially offset Raman spectroscopy to detect differences in bone matrix quality. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 303:123240. [PMID: 37591015 PMCID: PMC10528408 DOI: 10.1016/j.saa.2023.123240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Revised: 07/03/2023] [Accepted: 08/04/2023] [Indexed: 08/19/2023]
Abstract
Since spatially offset Raman spectroscopy (SORS) can acquire biochemical measurements of tissue quality through light scattering materials, we investigated the feasibility of this technique to acquire Raman bands related to the fracture resistance of bone. Designed to maximize signals at different offsets, a SORS probe was used to acquire spectra from cadaveric bone with and without skin-like tissue phantoms attenuating the light. Autoclaving the lateral side of femur mid-shafts from 5 female and 5 male donors at 100 °C and again at 120 °C reduced the yield stress of cortical beams subjected to three-point bending. It did not affect the volumetric bone mineral density or porosity. Without tissue phantoms, autoclaving affected more Raman characteristics of the organic matrix when determined by peak intensity ratios, but fewer matrix properties depended on the three offsets (5 mm, 6 mm, and 7 mm) when determined by band area ratios. The cut-off in the thickness of the tissue phantom layers was ∼4 mm for most properties, irrespective of offset. Matching trends when spectra were acquired without phantom layers between bone and the probe, ν1PO43-/Amide III and ν1PO43-/(proline + OH-proline) were higher and lower in the non-treated bone than in the autoclaved bone, respectively, when the thickness of tissue phantom layers was 4 mm. The layers, however, caused a loss of sensitivity to autoclaving-related changes in ν3CO3/ν1PO43- and crystallinity. Without advanced post-processing of Raman spectra, SORS acquisition through turbid layers can detect changes in Raman properties of bone that accompany a loss in bone strength.
Collapse
Affiliation(s)
- Rekha Gautam
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Biophotonics@Tyndall, IPIC, Tyndall National Institute, Cork, Ireland
| | - Rafay Ahmed
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Ezekiel Haugen
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
| | - Mustafa Unal
- Department of Bioengineering, Karamanoglu Mehmetbey University, Karaman, 70200, Turkey; Department of Biophysics, Faculty of Medicine, Karamanoglu Mehmetbey University, Karaman 70200, Turkey
| | - Sean Fitzgerald
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Anita Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Vanderbilt Biophotonics Center, 410 24th Ave. S., Nashville, TN 37232, USA
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA; Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA; Department of Veterans Affairs, Tennessee Valley Healthcare System, 1310 24th Ave. S., Nashville, TN 37212, USA.
| |
Collapse
|
7
|
Ahmed R, Unal M, Gautam R, Uppuganti S, Derasari S, Mahadevan-Jansen A, Nyman JS. Sensitivity of the amide I band to matrix manipulation in bone: a Raman micro-spectroscopy and spatially offset Raman spectroscopy study. Analyst 2023; 148:4799-4809. [PMID: 37602820 PMCID: PMC10528211 DOI: 10.1039/d3an00527e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
The fracture resistance of bone arises from the hierarchical arrangement of minerals, collagen fibrils (i.e., cross-linked triple helices of α1 and α2 collagen I chains), non-collagenous proteins, and water. Raman spectroscopy (RS) is not only sensitive to the relative fractions of these constituents, but also to the secondary structure of bone proteins. To assess the ability of RS to detect differences in the protein structure, we quantified the effect of sequentially autoclaving (AC) human cortical bone at 100 °C (∼34.47 kPa) and then at 120 °C (∼117.21 kPa) on the amide I band using a commercial Raman micro-spectroscopy (μRS) instrument and custom spatially offset RS (SORS) instrument in which rings of collection fiber optics are offset from the central excitation fiber optics within a hand-held, cylindrical probe. Being clinically viable, measurements by SORS involved collecting Raman spectra of cadaveric femur mid-shafts (5 male & 5 female donors) through layers of a tissue mimic. Otherwise, μRS and SORS measurements were acquired directly from each bone. AC-related changes in the helical status of collagen I were assessed using amide I sub-peak ratios (intensity, I, at ∼1670 cm-1 relative to intensities at ∼1610 cm-1 and ∼1640 cm-1). The autoclaving manipulation significantly decreased the selected amide I sub-peak ratios as well as shifted peaks at ∼1605 cm-1 (μRS), ∼1636 cm-1 (SORS) and ∼1667 cm-1 in both μRS and SORS. Compared to μRS, SORS detected more significant differences in the amide I sub-peak ratios when the fiber optic probe was directly applied to bone. SORS also detected AC-related decreases in I1670/I1610 and I1670/I1640 when spectra were acquired through layers of the tissue mimic with a thickness ≤2 mm by the 7 mm offset ring, but not with the 5 mm or 6 mm offset ring. Overall, the SORS instrument was more sensitive than the conventional μRS instrument to pressure- and temperature-related changes in the organic matrix that affect the fracture resistance of bone, but SORS analysis of the amide I band is limited to an overlying thickness layer of 2 mm.
Collapse
Affiliation(s)
- Rafay Ahmed
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Mustafa Unal
- Department of Bioengineering, Karamanoglu Mehmetbey University, Karaman, Türkiye 70200
- Department of Biophysics, Faculty of Medicine, Karamanoglu Mehmetbey University, Karaman, Türkiye 70200.
| | - Rekha Gautam
- Biophotonics@Tyndall, IPIC, Tyndall National Institute, Cork, Ireland
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
- Vanderbilt Biophotonics Center, 410 24th Ave. S., Nashville, TN 37232, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
| | - Shrey Derasari
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
- Vanderbilt Biophotonics Center, 410 24th Ave. S., Nashville, TN 37232, USA
| | - Anita Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
- Vanderbilt Biophotonics Center, 410 24th Ave. S., Nashville, TN 37232, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, 1215 21st Ave. S., Suite 4200, Nashville, TN 37232, USA
- Department of Biomedical Engineering, Vanderbilt University, 5824 Stevenson Center, Nashville, TN 37232, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, 1310 24th Ave. S., Nashville, TN 37212, USA
| |
Collapse
|
8
|
Noordwijk KJ, Chen L, Ruspi BD, Schurer S, Papa B, Fasanello DC, McDonough SP, Palmer SE, Porter IR, Basran PS, Donnelly E, Reesink HL. Metacarpophalangeal Joint Pathology and Bone Mineral Density Increase with Exercise but Not with Incidence of Proximal Sesamoid Bone Fracture in Thoroughbred Racehorses. Animals (Basel) 2023; 13:ani13050827. [PMID: 36899684 PMCID: PMC10000193 DOI: 10.3390/ani13050827] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/20/2023] [Accepted: 02/22/2023] [Indexed: 03/03/2023] Open
Abstract
Proximal sesamoid bone (PSB) fracture is the leading cause of fatal musculoskeletal injury in Thoroughbred racehorses in Hong Kong and the US. Efforts are underway to investigate diagnostic modalities that could help identify racehorses at increased risk of fracture; however, features associated with PSB fracture risk are still poorly understood. The objectives of this study were to (1) investigate third metacarpal (MC3) and PSB density and mineral content using dual-energy X-ray absorptiometry (DXA), computed tomography (CT), Raman spectroscopy, and ash fraction measurements, and (2) investigate PSB quality and metacarpophalangeal joint (MCPJ) pathology using Raman spectroscopy and CT. Forelimbs were collected from 29 Thoroughbred racehorse cadavers (n = 14 PSB fracture, n = 15 control) for DXA and CT imaging, and PSBs were sectioned for Raman spectroscopy and ash fraction measurements. Bone mineral density (BMD) was greater in MC3 condyles and PSBs of horses with more high-speed furlongs. MCPJ pathology, including palmar osteochondral disease (POD), MC3 condylar sclerosis, and MC3 subchondral lysis were greater in horses with more high-speed furlongs. There were no differences in BMD or Raman parameters between fracture and control groups; however, Raman spectroscopy and ash fraction measurements revealed regional differences in PSB BMD and tissue composition. Many parameters, including MC3 and PSB bone mineral density, were strongly correlated with total high-speed furlongs.
Collapse
Affiliation(s)
- Kira J. Noordwijk
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Leyi Chen
- Department of Materials Science and Engineering, College of Engineering, Cornell University, Ithaca, NY 14853, USA
| | - Bianca D. Ruspi
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Sydney Schurer
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Brittany Papa
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Diana C. Fasanello
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Sean P. McDonough
- Department of Biomedical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Scott E. Palmer
- Department of Population Medicine and Diagnostic Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Ian R. Porter
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Parminder S. Basran
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | - Eve Donnelly
- Department of Materials Science and Engineering, College of Engineering, Cornell University, Ithaca, NY 14853, USA
- Correspondence: (E.D.); (H.L.R.)
| | - Heidi L. Reesink
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
- Correspondence: (E.D.); (H.L.R.)
| |
Collapse
|
9
|
Willett TL, Voziyan P, Nyman JS. Causative or associative: A critical review of the role of advanced glycation end-products in bone fragility. Bone 2022; 163:116485. [PMID: 35798196 PMCID: PMC10062699 DOI: 10.1016/j.bone.2022.116485] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 06/27/2022] [Accepted: 06/29/2022] [Indexed: 11/02/2022]
Abstract
The accumulation of advanced glycation end-products (AGEs) in the organic matrix of bone with aging and chronic disease such as diabetes is thought to increase fracture risk independently of bone mass. However, to date, there has not been a clinical trial to determine whether inhibiting the accumulation of AGEs is effective in preventing low-energy, fragility fractures. Moreover, unlike with cardiovascular or kidney disease, there are also no pre-clinical studies demonstrating that AGE inhibitors or breakers can prevent the age- or diabetes-related decrease in the ability of bone to resist fracture. In this review, we critically examine the case for a long-standing hypothesis that AGE accumulation in bone tissue degrades the toughening mechanisms by which bone resists fracture. Prior research into the role of AGEs in bone has primarily measured pentosidine, an AGE crosslink, or bulk fluorescence of hydrolysates of bone. While significant correlations exist between these measurements and mechanical properties of bone, multiple AGEs are both non-fluorescent and non-crosslinking. Since clinical studies are equivocal on whether circulating pentosidine is an indicator of elevated fracture risk, there needs to be a more complete understanding of the different types of AGEs including non-crosslinking adducts and multiple non-enzymatic crosslinks in bone extracellular matrix and their specific contributions to hindering fracture resistance (biophysical and biological). By doing so, effective strategies to target AGE accumulation in bone with minimal side effects could be investigated in pre-clinical and clinical studies that aim to prevent fragility fractures in conditions that bone mass is not the underlying culprit.
Collapse
Affiliation(s)
- Thomas L Willett
- Biomedical Engineering Program, Systems Design Engineering, University of Waterloo, Waterloo, Ontario, Canada.
| | - Paul Voziyan
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, USA.
| |
Collapse
|
10
|
Ahmed R, Uppuganti S, Derasari S, Meyer J, Pennings JS, Elefteriou F, Nyman JS. Identifying Bone Matrix Impairments in a Mouse Model of Neurofibromatosis Type 1 (NF1) by Clinically Translatable Techniques. J Bone Miner Res 2022; 37:1603-1621. [PMID: 35690920 PMCID: PMC9378557 DOI: 10.1002/jbmr.4633] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 05/25/2022] [Accepted: 06/04/2022] [Indexed: 11/06/2022]
Abstract
Three-to-four percent of children with neurofibromatosis type 1 (NF1) present with unilateral tibia bowing, fracture, and recalcitrant healing. Alkaline phosphatase (ALP) enzyme therapy prevented poor bone mineralization and poor mechanical properties in mouse models of NF1 skeletal dysplasia; but transition to clinical trials is hampered by the lack of a technique that (i) identifies NF1 patients at risk of tibia bowing and fracture making them eligible for trial enrollment and (ii) monitors treatment effects on matrix characteristics related to bone strength. Therefore, we assessed the ability of matrix-sensitive techniques to provide characteristics that differentiate between cortical bone from mice characterized by postnatal loss of Nf1 in Osx-creTet-Off ;Nf1flox/flox osteoprogenitors (cKO) and from wild-type (WT) mice. Following euthanasia at two time points of bone disease progression, femur and tibia were harvested from both genotypes (n ≥ 8/age/sex/genotype). A reduction in the mid-diaphysis ultimate force during three-point bending at 20 weeks confirmed deleterious changes in bone induced by Nf1 deficiency, regardless of sex. Pooling females and males, low bound water (BW), and low cortical volumetric bone mineral density (Ct.vBMD) were the most accurate outcomes in distinguishing cKO from WT femurs with accuracy improving with age. Ct.vBMD and the average unloading slope (Avg-US) from cyclic reference point indentation tests were the most sensitive in differentiating WT from cKO tibias. Mineral-to-matrix ratio and carbonate substitution from Raman spectroscopy were not good classifiers. However, when combined with Ct.vBMD and BW (femur), they helped predict bending strength. Nf1 deficiency in osteoprogenitors negatively affected bone microstructure and matrix quality with deficits in properties becoming more pronounced with duration of Nf1 deficiency. Clinically measurable without ionizing radiation, BW and Avg-US are sensitive to deleterious changes in bone matrix in a preclinical model of NF1 bone dysplasia and require further clinical investigation as potential indicators of an onset of bone weakness in children with NF1. © 2022 American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Rafay Ahmed
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Shrey Derasari
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Joshua Meyer
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Jacquelyn S Pennings
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.,Center for Musculoskeletal Research, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Florent Elefteriou
- Department of Molecular and Human Genetics, Baylor College of Medicine, Houston, TX, USA.,Department of Orthopaedic Surgery, Baylor College of Medicine, Houston, TX, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN, USA.,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA.,Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.,Center for Musculoskeletal Research, Vanderbilt University Medical Center, Nashville, TN, USA.,Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
| |
Collapse
|
11
|
Dooley M, Paterson T, Dexter L, Matousek P, Dehghani H, Notingher I. Model-Based Optimization of Laser Excitation and Detection Improves Spectral Contrast in Noninvasive Diffuse Raman Spectroscopy. APPLIED SPECTROSCOPY 2022; 76:801-811. [PMID: 35081779 DOI: 10.1177/00037028211072900] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Spatially offset Raman spectroscopy (SORS) is a powerful technique for subsurface molecular analysis of optically turbid samples. Numerical modeling of light propagation has been used to investigate opportunities for improving spectral contrast and signal to noise ratio when imaging regions of interest located 0-4.5 mm below the surface in polymer bulk material. Two- and three-dimensional modeling results demonstrate that when analyzing a certain region of interest (ROI) of finite lateral dimensions below the sample surface, offsetting both the laser source and detector in opposite directions from the central point of the ROI can increase the spectral contrast as compared to conventional SORS approach where the detector or the laser source is maintained at the central point (centered SORS). The outlined modeling results have been validated experimentally using a bulk polymer sample with a trans-stilbene ROI (cylinder) below the sample surface. The results show that modeling of the spatial configurations of laser excitation and detection points can be used to optimize the instrument configuration to achieve significant improvements (up to 2.25-fold) in performance over the conventional centered SORS. Such optimal solutions can then be implemented, for example, using robust fiber optic probes, moveable optics, or flexible spatial light modulator instruments for specific applications.
Collapse
Affiliation(s)
- Max Dooley
- School of Physics and Astronomy, 6123University of Nottingham, Nottingham, UK
| | - Thomas Paterson
- School of Physics and Astronomy, 6123University of Nottingham, Nottingham, UK
| | - Louise Dexter
- School of Physics and Astronomy, 6123University of Nottingham, Nottingham, UK
| | - Pavel Matousek
- Central Laser Facility, UK Research and Innovation (UKRI), STFC Rutherford Appleton Laboratory, Harwell Oxford, UK
| | - Hamid Dehghani
- School of Computer Sciences, 1724University of Birmingham, Birmingham, UK
| | - Ioan Notingher
- School of Physics and Astronomy, 6123University of Nottingham, Nottingham, UK
| |
Collapse
|
12
|
Abstract
Raman spectroscopy (RS) is used to analyze the physiochemical properties of bone because it is non-destructive and requires minimal sample preparation. With over two decades of research involving measurements of mineral-to-matrix ratio, type-B carbonate substitution, crystallinity, and other compositional characteristics of the bone matrix by RS, there are multiple methods to acquire Raman signals from bone, to process those signals, and to determine peak ratios including sub-peak ratios as well as the full-width at half maximum of the most prominent Raman peak, which is nu1 phosphate (ν1PO4). Selecting which methods to use is not always clear. Herein, we describe the components of RS instruments and how they influence the quality of Raman spectra acquired from bone because signal-to-noise of the acquisition and the accompanying background fluorescence dictate the pre-processing of the Raman spectra. We also describe common methods and challenges in preparing acquired spectra for the determination of matrix properties of bone. This article also serves to provide guidance for the analysis of bone by RS with examples of how methods for pre-processing the Raman signals and for determining properties of bone composition affect RS sensitivity to potential differences between experimental groups. Attention is also given to deconvolution methods that are used to ascertain sub-peak ratios of the amide I band as a way to assess characteristics of collagen type I. We provide suggestions and recommendations on the application of RS to bone with the goal of improving reproducibility across studies and solidify RS as a valuable technique in the field of bone research.
Collapse
Affiliation(s)
- Mustafa Unal
- Department of Mechanical Engineering, Karamanoglu Mehmetbey University, Karaman, 70200, Turkey.
- Department of Bioengineering, Karamanoglu Mehmetbey University, Karaman, Turkey 70200
- Department of Biophysics, Faculty of Medicine, Karamanoglu Mehmetbey University, Karaman, Turkey 70200
| | - Rafay Ahmed
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA.
| | - Anita Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37235, USA
- Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Otolaryngology, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery, Vanderbilt University Medical Center, Nashville, TN 37232, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37235, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, USA
| |
Collapse
|
13
|
Abstract
PURPOSE OF REVIEW We re-evaluated clinical applications of image-to-FE models to understand if clinical advantages are already evident, which proposals are promising, and which questions are still open. RECENT FINDINGS CT-to-FE is useful in longitudinal treatment evaluation and groups discrimination. In metastatic lesions, CT-to-FE strength alone accurately predicts impending femoral fractures. In osteoporosis, strength from CT-to-FE or DXA-to-FE predicts incident fractures similarly to DXA-aBMD. Coupling loads and strength (possibly in dynamic models) may improve prediction. One promising MRI-to-FE workflow may now be tested on clinical data. Evidence of artificial intelligence usefulness is appearing. CT-to-FE is already clinical in opportunistic CT screening for osteoporosis, and risk of metastasis-related impending fractures. Short-term keys to improve image-to-FE in osteoporosis may be coupling FE with fall risk estimates, pool FE results with other parameters through robust artificial intelligence approaches, and increase reproducibility and cross-validation of models. Modeling bone modifications over time and bone fracture mechanics are still open issues.
Collapse
Affiliation(s)
- Enrico Schileo
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
| | - Fulvia Taddei
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
14
|
Chen K, Massie C, Awad HA, Berger AJ. Determination of best Raman spectroscopy spatial offsets for transcutaneous bone quality assessments in human hands. BIOMEDICAL OPTICS EXPRESS 2021; 12:7517-7525. [PMID: 35003849 PMCID: PMC8713657 DOI: 10.1364/boe.440297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 10/20/2021] [Accepted: 10/20/2021] [Indexed: 06/14/2023]
Abstract
Spatially offset Raman spectroscopy (SORS) is able to detect bone signal transcutaneously and could assist in predicting bone fracture risk. Criteria for optimal source-detector offsets for transcutaneous human measurements, however, are not well-established. Although larger offsets yield a higher percentage of bone signal, the absolute amount of bone signal decreases. Spectral unmixing into bone, adipose, and non-adipose components was employed to quantify changes in bone signal to noise ratio across a range of offsets, and optimal offsets for phalanx and metacarpal measurements were determined. The bone signal to noise ratio was maximized at offsets ranging from 4-6 mm.
Collapse
Affiliation(s)
- Keren Chen
- The Institute of Optics, University of Rochester, Rochester, NY 14620, USA
- Joint co-authors
| | - Christine Massie
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14620, USA
- Joint co-authors
| | - Hani A. Awad
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14620, USA
- Department of Orthopaedics and Rehabilitation, University of Rochester Medical Center, Rochester, NY 14620, USA
| | - Andrew J. Berger
- The Institute of Optics, University of Rochester, Rochester, NY 14620, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14620, USA
| |
Collapse
|
15
|
Fosca M, Basoli V, Della Bella E, Russo F, Vadala G, Alini M, Rau JV, Verrier S. Raman spectroscopy in skeletal tissue disorders and tissue engineering: present and prospective. TISSUE ENGINEERING PART B-REVIEWS 2021; 28:949-965. [PMID: 34579558 DOI: 10.1089/ten.teb.2021.0139] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Musculoskeletal disorders are the most common reason of chronic pain and disability representing worldwide an enormous socio-economic burden. In this review, new biomedical application fields for Raman spectroscopy (RS) technique related to skeletal tissues are discussed showing that it can provide a comprehensive profile of tissue composition in situ, in a rapid, label-free, and non-destructive manner. RS can be used as a tool to study tissue alterations associated to aging, pathologies, and disease treatments. The main advantage with respect to currently applied methods in clinics is its ability to provide specific information on molecular composition, which goes beyond other diagnostic tools. Being compatible with water, RS can be performed without pre-treatment on unfixed, hydrated tissue samples, without any labelling and chemical fixation used in histochemical methods. This review provides first the description of basic principles of RS as a biotechnology tool and introduces into the field of currently available RS based techniques, developed to enhance Raman signal. The main spectral processing statistical tools, fingerprint identification and available databases are mentioned. The recent literature has been analysed for such applications of RS as tendon and ligaments, cartilage, bone, and tissue engineered constructs for regenerative medicine. Several cases of proof-of-concept preclinical studies have been described. Finally, advantages, limitations, future perspectives, and challenges for translation of RS into clinical practice have been also discussed.
Collapse
Affiliation(s)
- Marco Fosca
- Istituto di Struttura della Materia Consiglio Nazionale delle Ricerche, 204549, Roma, Lazio, Italy;
| | - Valentina Basoli
- AO Research Institute Davos, 161930, Regenerative Orthopaedics, Davos, Graubünden, Switzerland;
| | - Elena Della Bella
- AO Research Institute Davos, 161930, Regenerative Orthopaedics, Davos, Graubünden, Switzerland;
| | - Fabrizio Russo
- Campus Bio-Medico University Hospital, 220431, Roma, Lazio, Italy;
| | - Gianluca Vadala
- Campus Bio-Medico University Hospital, 220431, Roma, Lazio, Italy;
| | - Mauro Alini
- AO Research Institute Davos, 161930, Regenerative Orthopaedics, Davos, Graubünden, Switzerland;
| | - Julietta V Rau
- Istituto di Struttura della Materia Consiglio Nazionale delle Ricerche, 204549, Roma, Lazio, Italy.,I M Sechenov First Moscow State Medical University, 68477, Moskva, Moskva, Russian Federation;
| | - Sophie Verrier
- AO Research Institute Davos, 161930, Regenerative Orthopaedics, Davos, Graubünden, Switzerland;
| |
Collapse
|
16
|
Shepherd RF, Kerns JG, Ranganath LR, Gallagher JA, Taylor AM. "Lessons from Rare Forms of Osteoarthritis". Calcif Tissue Int 2021; 109:291-302. [PMID: 34417863 PMCID: PMC8403118 DOI: 10.1007/s00223-021-00896-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 07/27/2021] [Indexed: 12/12/2022]
Abstract
Osteoarthritis (OA) is one of the most prevalent conditions in the world, particularly in the developed world with a significant increase in cases and their predicted impact as we move through the twenty-first century and this will be exacerbated by the covid pandemic. The degeneration of cartilage and bone as part of this condition is becoming better understood but there are still significant challenges in painting a complete picture to recognise all aspects of the condition and what treatment(s) are most appropriate in individual causes. OA encompasses many different types and this causes some of the challenges in fully understanding the condition. There have been examples through history where much has been learnt about common disease(s) from the study of rare or extreme phenotypes, particularly where Mendelian disorders are involved. The often early onset of symptoms combined with the rapid and aggressive pathogenesis of these diseases and their predictable outcomes give an often-under-explored resource. It is these "rarer forms of disease" that William Harvey referred to that offer novel insights into more common conditions through their more extreme presentations. In the case of OA, GWAS analyses demonstrate the multiple genes that are implicated in OA in the general population. In some of these rarer forms, single defective genes are responsible. The extreme phenotypes seen in conditions such as Camptodactyly Arthropathy-Coxa Vara-pericarditis Syndrome, Chondrodysplasias and Alkaptonuria all present potential opportunities for greater understanding of disease pathogenesis, novel therapeutic interventions and diagnostic imaging. This review examines some of the rarer presenting forms of OA and linked conditions, some of the novel discoveries made whilst studying them, and findings on imaging and treatment strategies.
Collapse
Affiliation(s)
- Rebecca F Shepherd
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Lancaster, UK
| | - Jemma G Kerns
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Lancaster, UK
| | - Lakshminarayan R Ranganath
- Departments of Clinical Biochemistry and Metabolic Medicine, Royal Liverpool University Hospital, Liverpool, L7 8XP, UK
| | - James A Gallagher
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, L7 8T, UK
| | - Adam M Taylor
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Lancaster, UK.
| |
Collapse
|
17
|
Gaihre B, Bharadwaz A, Unagolla JM, Jayasuriya AC. Evaluation of the optimal dosage of BMP-9 through the comparison of bone regeneration induced by BMP-9 versus BMP-2 using an injectable microparticle embedded thermosensitive polymeric carrier in a rat cranial defect model. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112252. [PMID: 34225891 PMCID: PMC8260961 DOI: 10.1016/j.msec.2021.112252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 05/03/2021] [Accepted: 06/07/2021] [Indexed: 01/07/2023]
Abstract
Bone morphogenetic proteins (BMPs) are well known as enhancers and facilitators of osteogenesis during bone regeneration. The use of recombinant BMP-2 (rhBMP-2) in bone defect healing has drawbacks, which has driven the scouting for alternatives, such as recombinant BMP-9 (rhBMP-9), to provide comparable new bone formation. However, the dosage of rhBMP-9 is quintessential for the facilitation of adequate bone defect healing. Therefore, this study has been designed to evaluate the optimal dosage of BMP-9 by comparing the bone defect healing induced by rhBMP-9 over rhBMP-2. The chitosan (CS) microparticles (MPs), coated with BMPs, were embedded in a thermoresponsive methylcellulose (MC) and calcium alginate (Alg) based injectable delivery system containing a dosage of either 0.5 μg or 1.5 μg of the respective rhBMP per bone defect. A 5 mm critical-sized cranial defect rat model has been used in this study, and bone tissues were harvested at eight weeks post-surgery. The standard tools for comparing the new bone regeneration included micro computerized tomography (micro-CT) and histological analysis. A novel perspective of analyzing the new bone quality and crystallinity was employed by using Raman spectroscopy, along with its elastic modulus quantified through Atomic Force Microscopy (AFM). Results showed that the rhBMP-9 administered at a dosage of 1.5 μg per bone defect, using this delivery system, can adequately facilitate the bone void filling with ample new bone mineralization and crystallinity as compared to rhBMP-2, thus approving the hypothesis for a viable rhBMP-2 alternative.
Collapse
Affiliation(s)
- Bipin Gaihre
- Biomedical Engineering Program, Department of Bioengineering, College of Engineering, The University of Toledo, Toledo, OH 43607, USA
| | - Angshuman Bharadwaz
- Biomedical Engineering Program, Department of Bioengineering, College of Engineering, The University of Toledo, Toledo, OH 43607, USA
| | - Janitha M Unagolla
- Biomedical Engineering Program, Department of Bioengineering, College of Engineering, The University of Toledo, Toledo, OH 43607, USA
| | - Ambalangodage C Jayasuriya
- Biomedical Engineering Program, Department of Bioengineering, College of Engineering, The University of Toledo, Toledo, OH 43607, USA; Department of Orthopaedic Surgery, College of Medicine and Life Sciences, The University of Toledo, Toledo, OH 43614, USA.
| |
Collapse
|
18
|
Mandair GS, Akhter MP, Esmonde-White FWL, Lappe JM, Bare SP, Lloyd WR, Long JP, Lopez J, Kozloff KM, Recker RR, Morris MD. Altered collagen chemical compositional structure in osteopenic women with past fractures: A case-control Raman spectroscopic study. Bone 2021; 148:115962. [PMID: 33862262 PMCID: PMC8259347 DOI: 10.1016/j.bone.2021.115962] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2020] [Revised: 03/25/2021] [Accepted: 04/08/2021] [Indexed: 12/17/2022]
Abstract
Incidences of low-trauma fractures among osteopenic women may be related to changes in bone quality. In this blinded, prospective-controlled study, compositional and heterogeneity contributors of bone quality to fracture risk were examined. We hypothesize that Raman spectroscopy can differentiate between osteopenic women with one or more fractures (cases) from women without fractures (controls). This study involved the Raman spectroscopic analysis of cortical and cancellous bone composition using iliac crest biopsies obtained from 59-cases and 59-controls, matched for age (62.0 ± 7.5 and 61.7 ± 7.3 years, respectively, p = 0.38) and hip bone mineral density (BMD, 0.827 ± 0.083 and 0.823 ± 0.072 g/cm3, respectively, p = 0.57). Based on aggregate univariate case-control and odds ratio based logistic regression analyses, we discovered two Raman ratiometric parameters that were predictive of past fracture risk. Specifically, 1244/1268 and 1044/959 cm-1 ratios, were identified as the most differential aspects of bone quality in cortical cases with odds ratios of 0.617 (0.406-0.938 95% CI, p = 0.024) and 1.656 (1.083-2.534 95% CI, p = 0.020), respectively. Both 1244/1268 and 1044/959 cm-1 ratios exhibited moderate sensitivity (59.3-64.4%) but low specificity (49.2-52.5%). These results suggest that the organization of mineralized collagen fibrils were significantly altered in cortical cases compared to controls. In contrast, compositional and heterogeneity parameters related to mineral/matrix ratios, B-type carbonate substitutions, and mineral crystallinity, were not significantly different between cases and controls. In conclusion, a key outcome of this study is the significant odds ratios obtained for two Raman parameters (1244/1268 and 1044/959 cm-1 ratios), which from a diagnostic perspective, may assist in the screening of osteopenic women with suspected low-trauma fractures. One important implication of these findings includes considering the possibility that changes in the organization of collagen compositional structure plays a far greater role in postmenopausal women with osteopenic fractures.
Collapse
Affiliation(s)
- Gurjit S Mandair
- School of Dentistry, Departments of Biologic and Materials, University of Michigan, Ann Arbor, MI, USA.
| | | | | | - Joan M Lappe
- Osteoporosis Research Center, Creighton University, Omaha, NE, USA
| | - Susan P Bare
- Osteoporosis Research Center, Creighton University, Omaha, NE, USA
| | - William R Lloyd
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| | - Jason P Long
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, USA
| | - Jessica Lopez
- School of Dentistry, Departments of Biologic and Materials, University of Michigan, Ann Arbor, MI, USA
| | - Kenneth M Kozloff
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, USA
| | - Robert R Recker
- Osteoporosis Research Center, Creighton University, Omaha, NE, USA
| | - Michael D Morris
- Department of Chemistry, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
19
|
Magnesium whitlockite - omnipresent in pathological mineralisation of soft tissues but not a significant inorganic constituent of bone. Acta Biomater 2021; 125:72-82. [PMID: 33610767 DOI: 10.1016/j.actbio.2021.02.021] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/26/2021] [Accepted: 02/12/2021] [Indexed: 01/03/2023]
Abstract
Whitlockite is a calcium phosphate that was first identified in minerals collected from the Palermo Quarry, New Hampshire. The terms magnesium whitlockite [Mg-whitlockite; Ca18Mg2(HPO4)2(PO4)12] and beta-tricalcium phosphate [β-TCP; β-Ca3(PO4)2] are often used interchangeably since Mg-whitlockite is not easily distinguished from β-Ca3(PO4)2 by powder X-ray diffraction although their crystalline structures differ significantly. Being both osteoconductive and bioresorbable, Mg-whitlockite is pursued as a synthetic bone graft substitute. In recent years, advances in development of synthetic Mg-whitlockite have been accompanied by claims that Mg-whitlockite is the second most abundant inorganic constituent of bone, occupying as much as 20-35 wt% of the inorganic fraction. To find evidence in support of this notion, this review presents an exhaustive summary of Mg-whitlockite identification in biological tissues. Mg-whitlockite is mainly found in association with pathological mineralisation of various soft tissues and dental calculus, and occasionally with enamel and dentine. With the exception of high-temperature treated tumoural calcified deposits around interphalangeal and metacarpal joints and rhomboidal Mg-whitlockite crystals in post-apoptotic osteocyte lacunae in human alveolar bone, this unusual mineral has never been detected in the extracellular matrix of mammalian bone. Characterisation techniques capable of unequivocally distinguishing between different calcium phosphate phases, such as high-resolution imaging, crystallography, and/or spectroscopy have exclusively identified bone mineral as poorly crystalline, ion-substituted, carbonated apatite. The idea that Mg-whitlockite is a significant constituent of bone mineral remains unsubstantiated. Contrary to claims that such biomaterials represent a bioinspired/biomimetic approach to bone repair, Mg-whitlockite remains, exclusively, a pathological biomineral. STATEMENT OF SIGNIFICANCE: Magnesium whitlockite (Mg-whitlockite) is a unique calcium phosphate that typically features in pathological calcification of soft tissues; however, an alarming trend emerging in the synthetic bioceramics community claims that Mg-whitlockite occupies 20-35 wt% of bone mineral and therefore synthetic Mg-whitlockite represents a biomimetic approach towards bone regeneration. By providing an overview of Mg-whitlockite detection in biological tissues and scrutinising a diverse cross-section of literature relevant to bone composition analysis, this review concludes that Mg-whitlockite is exclusively a pathological biomineral, and having never been reported in bone extracellular matrix, Mg-whitlockite does not constitute a biomimetic strategy for bone repair.
Collapse
|
20
|
Querido W, Kandel S, Pleshko N. Applications of Vibrational Spectroscopy for Analysis of Connective Tissues. Molecules 2021; 26:922. [PMID: 33572384 PMCID: PMC7916244 DOI: 10.3390/molecules26040922] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/30/2021] [Accepted: 02/04/2021] [Indexed: 02/07/2023] Open
Abstract
Advances in vibrational spectroscopy have propelled new insights into the molecular composition and structure of biological tissues. In this review, we discuss common modalities and techniques of vibrational spectroscopy, and present key examples to illustrate how they have been applied to enrich the assessment of connective tissues. In particular, we focus on applications of Fourier transform infrared (FTIR), near infrared (NIR) and Raman spectroscopy to assess cartilage and bone properties. We present strengths and limitations of each approach and discuss how the combination of spectrometers with microscopes (hyperspectral imaging) and fiber optic probes have greatly advanced their biomedical applications. We show how these modalities may be used to evaluate virtually any type of sample (ex vivo, in situ or in vivo) and how "spectral fingerprints" can be interpreted to quantify outcomes related to tissue composition and quality. We highlight the unparalleled advantage of vibrational spectroscopy as a label-free and often nondestructive approach to assess properties of the extracellular matrix (ECM) associated with normal, developing, aging, pathological and treated tissues. We believe this review will assist readers not only in better understanding applications of FTIR, NIR and Raman spectroscopy, but also in implementing these approaches for their own research projects.
Collapse
Affiliation(s)
| | | | - Nancy Pleshko
- Department of Bioengineering, Temple University, Philadelphia, PA 19122, USA; (W.Q.); (S.K.)
| |
Collapse
|
21
|
Nicolson F, Kircher MF, Stone N, Matousek P. Spatially offset Raman spectroscopy for biomedical applications. Chem Soc Rev 2021; 50:556-568. [PMID: 33169761 PMCID: PMC8323810 DOI: 10.1039/d0cs00855a] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Indexed: 12/24/2022]
Abstract
In recent years, Raman spectroscopy has undergone major advancements in its ability to probe deeply through turbid media such as biological tissues. This progress has been facilitated by the advent of a range of specialist techniques based around spatially offset Raman spectroscopy (SORS) to enable non-invasive probing of living tissue through depths of up to 5 cm. This represents an improvement in depth penetration of up to two orders of magnitude compared to what can be achieved with conventional Raman methods. In combination with the inherently high molecular specificity of Raman spectroscopy, this has therefore opened up entirely new prospects for a range of new analytical applications across multiple fields including medical diagnosis and disease monitoring. This article discusses SORS and related variants of deep Raman spectroscopy such as transmission Raman spectroscopy (TRS), micro-SORS and surface enhanced spatially offset Raman spectroscopy (SESORS), and reviews the progress made in this field during the past 5 years including advances in non-invasive cancer diagnosis, monitoring of neurotransmitters, and assessment of bone disease.
Collapse
Affiliation(s)
- Fay Nicolson
- Department of Imaging, Dana-Farber Cancer Institute & Harvard Medical SchoolBostonMA 02215USA
| | - Moritz F. Kircher
- Department of Imaging, Dana-Farber Cancer Institute & Harvard Medical SchoolBostonMA 02215USA
- Department of Radiology, Brigham & Women's Hospital & Harvard Medical SchoolBostonMA 022115USA
| | - Nick Stone
- School of Physics and Astronomy, University of ExeterExeterEX4 4QLUK
- Royal Devon and Exeter NHS Foundation TrustBarrack RoadExeterDevonEX2 5DWUK
| | - Pavel Matousek
- Central Laser Facility, Research Complex at Harwell, STFC Rutherford Appleton Laboratory, UKRIHarwellOxfordOX11 0QXUK
| |
Collapse
|
22
|
Gardner B, Matousek P, Stone N. Self-absorption corrected non-invasive transmission Raman spectroscopy (of biological tissue). Analyst 2021; 146:1260-1267. [DOI: 10.1039/d0an01940b] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Higher contrast of subsurface Raman spectra is achievable with self-absorption corrected transmission Raman spectroscopy. (Desired signal in red, interfering matrix artefacts in blue.)
Collapse
Affiliation(s)
- Benjamin Gardner
- School of Physics and Astronomy
- University of Exeter
- Exeter
- UK
- Royal Devon and Exeter NHS Foundation Trust
| | - Pavel Matousek
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Harwell Oxford
- UK
| | - Nicholas Stone
- School of Physics and Astronomy
- University of Exeter
- Exeter
- UK
- Royal Devon and Exeter NHS Foundation Trust
| |
Collapse
|
23
|
Chen K, Massie C, Berger AJ. Soft-tissue spectral subtraction improves transcutaneous Raman estimates of murine bone strength in vivo. JOURNAL OF BIOPHOTONICS 2020; 13:e202000256. [PMID: 32749067 PMCID: PMC8320303 DOI: 10.1002/jbio.202000256] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/26/2020] [Accepted: 07/30/2020] [Indexed: 06/11/2023]
Abstract
Transcutaneous determination of a bone's Raman spectrum is challenging because the type I collagen in the overlying soft tissue is spectroscopically identical to that in bone. In a previous transcutaneous study of murine tibiae, we developed a library-based model called SOLD to unmix spatially offset Raman measurements into three spectra: a bone estimate, a soft tissue estimate, and a residual. Here, we demonstrate the value of combining the bone estimate and the residual to produce a "top layer subtracted" (tls) spectrum. We report superior prediction of two standard bone metrics (volumetric bone mineralization density and maximum torque) using partial least squares regression models based upon tls spectra rather than SOLD bone estimates, implying that the spectral residuals contain useful information. Simulations reinforce experimental in vivo findings. This chemometric approach, which we denote as SOLD/TLS, could have broad applicability in situations where comprehensive spectral libraries are difficult to acquire.
Collapse
Affiliation(s)
- Keren Chen
- The Institute of Optics, University of Rochester, New York, USA
- Contributed equally to this work and should be considered joint first authors
| | - Christine Massie
- Department of Biomedical Engineering, University of Rochester, New York, USA
- Contributed equally to this work and should be considered joint first authors
| | - Andrew J. Berger
- The Institute of Optics, University of Rochester, New York, USA
- Department of Biomedical Engineering, University of Rochester, New York, USA
| |
Collapse
|
24
|
Ailavajhala R, Querido W, Rajapakse CS, Pleshko N. Near infrared spectroscopic assessment of loosely and tightly bound cortical bone water. Analyst 2020; 145:3713-3724. [PMID: 32342066 DOI: 10.1039/c9an02491c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Water is an important component of bone and plays a key role in its mechanical and structural integrity. Water molecules in bone are present in different locations, including loosely or tightly bound to the matrix and/or mineral (biological apatite) phases. Identification of water location and interactions with matrix components impact bone function but have been challenging to assess. Here, we used near infrared (NIR) spectroscopy to identify loosely and tightly bound water present in cortical bone. In hydrated samples, NIR spectra have two primary water absorption bands at frequencies of ∼5200 and 7000 cm-1. Using lyophilization and hydrogen-deuterium exchange assays, we showed that these absorption bands are primarily associated with loosely bound bone water. Using further demineralization assays, thermal denaturation, and comparison to standards, we found that these absorption bands have underlying components associated with water molecules tightly bound to bone. In dehydrated samples, the peak at ∼5200 cm-1 was assigned to a combination of water tightly bound to collagen and to mineral, whereas the peak at 7000 cm-1 was exclusively associated with tightly bound mineral water. We also found significant positive correlations between the NIR mineral absorption bands and the mineral content as determined by an established mid infrared spectroscopic parameter, phosphate/amide I. Moreover, the NIR water data showed correlation trends with tissue mineral density (TMD) in cortical bone tissues. These observations reveal the ability of NIR spectroscopy to non-destructively identify loosely and tightly bound water in bone, which could have further applications in biomineralization and biomedical studies.
Collapse
|
25
|
Liendl L, Grillari J, Schosserer M. Raman fingerprints as promising markers of cellular senescence and aging. GeroScience 2020; 42:377-387. [PMID: 30715693 PMCID: PMC7205846 DOI: 10.1007/s11357-019-00053-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 01/17/2019] [Indexed: 12/15/2022] Open
Abstract
Due to our aging population, understanding of the underlying molecular mechanisms constantly gains more and more importance. Senescent cells, defined by being irreversibly growth arrested and associated with a specific gene expression and secretory pattern, accumulate with age and thus contribute to several age-related diseases. However, their specific detection, especially in vivo, is still a major challenge. Raman microspectroscopy is able to record biochemical fingerprints of cells and tissues, allowing a distinction between different cellular states, or between healthy and cancer tissue. Similarly, Raman microspectroscopy was already successfully used to distinguish senescent from non-senescent cells, as well as to investigate other molecular changes that occur at cell and tissue level during aging. This review is intended to give an overview about various applications of Raman microspectroscopy to study aging, especially in the context of detecting senescent cells.
Collapse
Affiliation(s)
- Lisa Liendl
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, 1190, Vienna, Austria
| | - Johannes Grillari
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, 1190, Vienna, Austria
- Evercyte GmbH, 1190, Vienna, Austria
- Christian Doppler Laboratory on Biotechnology of Skin Aging, 1190, Vienna, Austria
| | - Markus Schosserer
- Department of Biotechnology, University of Natural Resources and Life Sciences, Vienna, 1190, Vienna, Austria.
| |
Collapse
|
26
|
Taylor AM, Shepherd L. The potential of nitisinone for the treatment of alkaptonuria. Expert Opin Orphan Drugs 2019. [DOI: 10.1080/21678707.2019.1664899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- Adam M Taylor
- Lancaster Medical School, Lancaster University, Lancaster, UK
| | - Laura Shepherd
- Lancaster Medical School, Lancaster University, Lancaster, UK
| |
Collapse
|
27
|
Taylor AM, Jenks DD, Kammath VD, Norman BP, Dillon JP, Gallagher JA, Ranganath LR, Kerns JG. Raman Spectroscopy identifies differences in ochronotic and non-ochronotic cartilage; a potential novel technique for monitoring ochronosis. Osteoarthritis Cartilage 2019; 27:1244-1251. [PMID: 31022456 DOI: 10.1016/j.joca.2019.04.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 04/08/2019] [Accepted: 04/10/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Alkaptonuria (AKU) is a rare, inherited disorder of tyrosine metabolism, where patients are unable to breakdown homogentisic acid (HGA), which increases systemically over time. It presents with a clinical triad of features; HGA in urine, ochronosis of collagenous tissues, and the subsequent ochronotic arthritis of these tissues. In recent years the advance in the understanding of the disease and the potential treatment of the disorder looks promising with the data on the efficacy of nitisinone. However, there are limited methods for the detection and monitoring of ochronosis in vivo, or for treatment monitoring. The study aim was to test the hypothesis that Raman spectra would identify a distinct chemical fingerprint for the non-ochronotic, compared to ochronotic cartilage. DESIGN Ochronotic and non-ochronotic cartilage from human hips and ears were analysed using Raman spectroscopy. RESULTS Non-ochronotic cartilage spectra were similar and reproducible and typical of normal articular cartilage. Conversely, the ochronotic cartilage samples were highly fluorescent and displayed limited or no discernible Raman peaks in the spectra, in stark contrast to their non-ochronotic pairs. Interestingly, a novel peak was observed associated with the polymer of HGA in the ochronotic cartilage that was confirmed by analysis of pigment derived from synthetic HGA. CONCLUSION This technique reveals novel data on the chemical differences in ochronotic compared with non-ochronotic cartilage, these differences are detectable by a technique that is already generating in vivo data and demonstrates the first possible procedure to monitor the progression of ochronosis in tissues of patients with AKU.
Collapse
Affiliation(s)
- A M Taylor
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Bailrigg, Lancaster, UK.
| | - D D Jenks
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Bailrigg, Lancaster, UK.
| | - V D Kammath
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Bailrigg, Lancaster, UK.
| | - B P Norman
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, UK.
| | - J P Dillon
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, UK.
| | - J A Gallagher
- Department of Musculoskeletal Biology, Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, UK.
| | - L R Ranganath
- Department of Clinical Biochemistry and Metabolic Medicine, Liverpool Clinical Laboratories, Royal Liverpool University Hospital, Liverpool, UK.
| | - J G Kerns
- Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Bailrigg, Lancaster, UK.
| |
Collapse
|
28
|
Unal M, Uppuganti S, Timur S, Mahadevan-Jansen A, Akkus O, Nyman JS. Assessing matrix quality by Raman spectroscopy helps predict fracture toughness of human cortical bone. Sci Rep 2019; 9:7195. [PMID: 31076574 PMCID: PMC6510799 DOI: 10.1038/s41598-019-43542-7] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2018] [Accepted: 04/26/2019] [Indexed: 01/10/2023] Open
Abstract
Developing clinical tools that assess bone matrix quality could improve the assessment of a person's fracture risk. To determine whether Raman spectroscopy (RS) has such potential, we acquired Raman spectra from human cortical bone using microscope- and fiber optic probe-based Raman systems and tested whether correlations between RS and fracture toughness properties were statistically significant. Calculated directly from intensities at wavenumbers identified by second derivative analysis, Amide I sub-peak ratio I1670/I1640, not I1670/I1690, was negatively correlated with Kinit (N = 58; R2 = 32.4%) and J-integral (R2 = 47.4%) when assessed by Raman micro-spectroscopy. Area ratios (A1670/A1690) determined from sub-band fitting did not correlate with fracture toughness. There were fewer correlations between RS and fracture toughness when spectra were acquired by probe RS. Nonetheless, the I1670/I1640 sub-peak ratio again negatively correlated with Kinit (N = 56; R2 = 25.6%) and J-integral (R2 = 39.0%). In best-fit general linear models, I1670/I1640, age, and volumetric bone mineral density explained 50.2% (microscope) and 49.4% (probe) of the variance in Kinit. I1670/I1640 and v1PO4/Amide I (microscope) or just I1670/I1640 (probe) were negative predictors of J-integral (adjusted-R2 = 54.9% or 37.9%, respectively). While Raman-derived matrix properties appear useful to the assessment of fracture resistance of bone, the acquisition strategy to resolve the Amide I band needs to be identified.
Collapse
Affiliation(s)
- Mustafa Unal
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN, 37212, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| | - Selin Timur
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Anita Mahadevan-Jansen
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN, 37212, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37212, USA
| | - Ozan Akkus
- Department of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
- Department of Orthopaedics, Case Western Reserve University, Cleveland, OH, 44106, USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN, 37212, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37212, USA.
| |
Collapse
|
29
|
Paolillo FR, Romano RA, de Matos L, Martin AA, Guimarães FEG, de Castro Neto JC, Bagnato VS. Short-term and long-term effects of osteoporosis on incisor teeth and femoral bones evaluated by Raman spectroscopy and energy dispersive X-ray analysis in ovariectomized rats. J Bone Miner Metab 2019; 37:18-27. [PMID: 29344812 DOI: 10.1007/s00774-018-0903-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Accepted: 01/04/2018] [Indexed: 01/05/2023]
Abstract
There are few published data on the relationship between loss of bone mass due to osteoporosis and poor tooth quality. This study analyzed the effects of osteoporosis on incisor teeth and femoral bones using optical techniques in rats. Twenty female Wistar rats aged 6 months (n = 20) were randomized into two groups: control group, non-ovariectomized rats (n = 10); ovariectomy group, ovariectomized rats to induce osteoporosis (n = 10). Each group was subdivided randomly into two groups containing five rats each as follows. Control group 1: non-ovariectomized rats euthanized at the age of 9 or 3 months post-ovariectomy (n = 5); Control group 2: non-ovariectomized rats euthanized at the age of 1 year or 6 months post-ovariectomy (n = 5); ovariectomy group 1: ovariectomized rats euthanized at the age of 9 months or 3 months post-ovariectomy (n = 5); ovariectomy group 2: ovariectomized rats euthanized at the age of 1 year or 6 months post-ovariectomy (n = 5). The incisor teeth and femoral bones of Wistar rats were removed to perform Raman spectroscopy using an excitation laser at 785 nm. In addition, an energy-dispersive X-ray spectrometer system was used to evaluate calcium (Ca) and phosphorus (P). The main findings included significant changes (p < 0.05) for phosphate and carbonate band areas for both incisor teeth and femur bones. In addition, there was significant negative correlation between the P concentration and phosphate/carbonate ratio (lower P content-larger ratio, p < 0.05) for incisor teeth and femoral bones. The proline and CH2 wag band areas were significantly reduced only for the incisor teeth (p < 0.05). Therefore, Raman spectroscopy assessed the compositional, physicochemical and structural changes in hard tissue. The current study also pointed out the possible action mechanisms of these changes, bone fracture risk and dental fragility. It is important to emphasize that poor dental quality may also occur due to osteoporosis.
Collapse
Affiliation(s)
- Fernanda Rossi Paolillo
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil.
| | - Renan Arnon Romano
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil
| | - Luciana de Matos
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil
| | - Airton Abrahão Martin
- Department of Physics from Federal University of Piauí (UFPI), Campus Universitário Ministro Petrônio Portella, Bairro Ininga, Teresina, Bairro Ininga, Teresina, PI 64049-550, Brazil
- Department of Biomedical Engineering from Brazil University (UnBr), Rua Carolina Fonseca, 584, Itaquera, SP, Brazil
| | - Francisco Eduardo Gontijo Guimarães
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil
| | - Jarbas Caiado de Castro Neto
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil
| | - Vanderlei Salvador Bagnato
- Optics Group from São Carlos Institute of Physics (IFSC), University of São Paulo (USP), Av. Trabalhador Sãocarlense, 400, Centro, São Carlos, SP, CEP 13560-970, Brazil
| |
Collapse
|
30
|
Shu C, Chen K, Lynch M, Maher JR, Awad HA, Berger AJ. Spatially offset Raman spectroscopy for in vivo bone strength prediction. BIOMEDICAL OPTICS EXPRESS 2018; 9:4781-4791. [PMID: 30319902 PMCID: PMC6179397 DOI: 10.1364/boe.9.004781] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 08/30/2018] [Accepted: 08/31/2018] [Indexed: 05/08/2023]
Abstract
Bone strength is a worldwide health concern. Although multiple techniques have been developed to evaluate bone quality, there are still gaps to be filled. Here we report a non-invasive approach for the prediction of bone strength in vivo using spatially offset Raman spectroscopy. Raman spectra were acquired transcutaneously from the tibiae of mice from 4 to 23 weeks old and subsequently on the exposed bones. Partial least squares regression was applied to generate predictions of the areal bone mineral density (aBMD), volumetric bone mineralization density (vBMD), and maximum torque (MT) of each tibia as quantified by dual-energy X-ray absorptiometry, microCT imaging, and biomechanical tests, respectively. Significant correlations were observed between Raman spectral predictions and the reference values in all three categories. To our knowledge, this is the first demonstration of Raman spectroscopy predicting a biomechanical bone parameter (MT) in vivo with an uncertainty much smaller than the spread in the reference values.
Collapse
Affiliation(s)
- Chi Shu
- The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14620, USA
- Contributed equally to this work and should be considered joint first authors
| | - Keren Chen
- The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14620, USA
- Contributed equally to this work and should be considered joint first authors
| | - Maria Lynch
- University of Rochester Medical Center, 601 Elmwood Ave, Rochester, NY 14642, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Jason R. Maher
- The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14620, USA
| | - Hani A. Awad
- University of Rochester Medical Center, 601 Elmwood Ave, Rochester, NY 14642, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| | - Andrew J. Berger
- The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14620, USA
- Department of Biomedical Engineering, University of Rochester, Rochester, NY 14627, USA
| |
Collapse
|
31
|
Unal M, Uppuganti S, Leverant CJ, Creecy A, Granke M, Voziyan P, Nyman JS. Assessing glycation-mediated changes in human cortical bone with Raman spectroscopy. JOURNAL OF BIOPHOTONICS 2018; 11:e201700352. [PMID: 29575566 PMCID: PMC6231413 DOI: 10.1002/jbio.201700352] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Accepted: 03/21/2018] [Indexed: 05/13/2023]
Abstract
Establishing a non-destructive method for spatially assessing advanced glycation end-products (AGEs) is a potentially useful step toward investigating the mechanistic role of AGEs in bone quality. To test the hypothesis that the shape of the amide I in the Raman spectroscopy (RS) analysis of bone matrix changes upon AGE accumulation, we incubated paired cadaveric cortical bone in ribose or glucose solutions and in control solutions for 4 and 16 weeks, respectively, at 37°C. Acquiring 10 spectra per bone with a 20X objective and a 830 nm laser, RS was sensitive to AGE accumulation (confirmed by biochemical measurements of pentosidine and fluorescent AGEs). Hyp/Pro ratio increased upon glycation using either 0.1 M ribose, 0.5 M ribose or 0.5 M glucose. Glycation also decreased the amide I sub-peak ratios (cm-1 ) 1668/1638 and 1668/1610 when directly calculated using either second derivative spectrum or local maxima of difference spectrum, though the processing method (eg, averaged spectrum vs individual spectra) to minimize noise influenced detection of differences for the ribose-incubated bones. Glycation however did not affect these sub-peak ratios including the matrix maturity ratio (1668/1690) when calculated using indirect sub-band fitting. The amide I sub-peak ratios likely reflected changes in the collagen I structure.
Collapse
Affiliation(s)
- Mustafa Unal
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Calen J. Leverant
- Department of Chemical & Biomolecular Engineering, Vanderbilt University, Nashville, TN 37232
| | - Amy Creecy
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
| | - Mathilde Granke
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Paul Voziyan
- Department of Medicine, Division of Nephrology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Jeffry S. Nyman
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
| |
Collapse
|
32
|
Abstract
The mechanical properties of bone are fundamental to the ability of our skeletons to support movement and to provide protection to our vital organs. As such, deterioration in mechanical behavior with aging and/or diseases such as osteoporosis and diabetes can have profound consequences for individuals' quality of life. This article reviews current knowledge of the basic mechanical behavior of bone at length scales ranging from hundreds of nanometers to tens of centimeters. We present the basic tenets of bone mechanics and connect them to some of the arcs of research that have brought the field to recent advances. We also discuss cortical bone, trabecular bone, and whole bones, as well as multiple aspects of material behavior, including elasticity, yield, fracture, fatigue, and damage. We describe the roles of bone quantity (e.g., density, porosity) and bone quality (e.g., cross-linking, protein composition), along with several avenues of future research.
Collapse
Affiliation(s)
- Elise F Morgan
- Orthopaedic and Developmental Biomechanics Laboratory, Department of Mechanical Engineering, Boston University, Boston, Massachusetts 02215, USA;
| | - Ginu U Unnikrisnan
- Orthopaedic and Developmental Biomechanics Laboratory, Department of Mechanical Engineering, Boston University, Boston, Massachusetts 02215, USA;
| | - Amira I Hussein
- Orthopaedic and Developmental Biomechanics Laboratory, Department of Mechanical Engineering, Boston University, Boston, Massachusetts 02215, USA;
| |
Collapse
|
33
|
Cordero E, Latka I, Matthäus C, Schie I, Popp J. In-vivo Raman spectroscopy: from basics to applications. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-23. [PMID: 29956506 DOI: 10.1117/1.jbo.23.7.071210] [Citation(s) in RCA: 114] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Accepted: 05/23/2018] [Indexed: 05/20/2023]
Abstract
For more than two decades, Raman spectroscopy has found widespread use in biological and medical applications. The instrumentation and the statistical evaluation procedures have matured, enabling the lengthy transition from ex-vivo demonstration to in-vivo examinations. This transition goes hand-in-hand with many technological developments and tightly bound requirements for a successful implementation in a clinical environment, which are often difficult to assess for novice scientists in the field. This review outlines the required instrumentation and instrumentation parameters, designs, and developments of fiber optic probes for the in-vivo applications in a clinical setting. It aims at providing an overview of contemporary technology and clinical trials and attempts to identify future developments necessary to bring the emerging technology to the clinical end users. A comprehensive overview of in-vivo applications of fiber optic Raman probes to characterize different tissue and disease types is also given.
Collapse
Affiliation(s)
- Eliana Cordero
- Leibniz-Institut für Photonische Technologien e.V., Germany
| | - Ines Latka
- Leibniz-Institut für Photonische Technologien e.V., Germany
| | - Christian Matthäus
- Leibniz-Institut für Photonische Technologien e.V., Germany
- Institut für Physikalische Chemie, Friedrich-Schiller-Univ. Jena, Germany
- Abbe Ctr. of Photonics, Germany
| | - Iwan Schie
- Leibniz-Institut für Photonische Technologien e.V., Germany
| | - Jürgen Popp
- Leibniz-Institut für Photonische Technologien e.V., Germany
- Institute für Physikalische Chemie, Friedrich-Schiller-Univ. Jena, Germany
| |
Collapse
|
34
|
Garip Ustaoglu S, Evis Z, Ilbay G, Boskey AL, Severcan F. Side-Effects of Convulsive Seizures and Anti-Seizure Therapy on Bone in a Rat Model of Epilepsy. APPLIED SPECTROSCOPY 2018; 72:689-705. [PMID: 28905646 DOI: 10.1177/0003702817734617] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The severe sole effects of seizures on the cortical part of bone were reported in our previous study. However, the side effects of anti-epileptic drug therapy on bones has not been differentiated from the effects of the convulsive seizures, yet. This study provides the first report on differentiation of the effects of seizures and carbamazepine (a widely used antiepileptic drug) therapy on bones; 50 mg/kg/day drug was given to genetically induced absence epileptic rats for five weeks. Distinct bone regions including cortical, trabecular, and growth plate in each of tibia, femur, and spine tissues were studied using Fourier transform infrared (FT-IR) imaging and Vickers microhardness test. Blood levels of vitamin D and bone turnover biomarkers were also measured. According to the FT-IR imaging results, both seizure and carbamazepine-treated groups, more dominantly the drug-treated group, had lower mineral content with altered collagen crosslinks and higher crystallinity, implying reduced bone strength. Lower microhardness values also supported lower mechanical strength in bones. The most affected bone tissue and region from seizures and treatment was found as the spine and cortical, respectively. While there was a reduction in vitamin D and calcium levels in both seizure and carbamazepin-treated groups, significantly elevated PTH and bone turnover biomarkers were only seen in the drug-treated group.
Collapse
Affiliation(s)
- Sebnem Garip Ustaoglu
- 1 Department of Biochemistry, 187458 Middle East Technical University , Ankara, Turkey
- 2 Department of Medical Biochemistry, 187458 Faculty of Medicine, Altinbas University, Istanbul, Turkey
| | - Zafer Evis
- 3 Department of Engineering Sciences, Middle East Technical University, Ankara, Turkey
| | - Gul Ilbay
- 4 Department of Physiology, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey
| | - Adele Ludin Boskey
- 5 25062 Mineralized Tissue Laboratory, Hospital for Special Surgery, New York, NY, USA
| | - Feride Severcan
- 6 Department of Biological Sciences, 187458 Middle East Technical University , Ankara, Turkey
- 7 Department of Biophysics, 187458 Faculty of Medicine, Altinbas University, Istanbul, Turkey
| |
Collapse
|
35
|
Affiliation(s)
- Garima Agrawal
- Department of Polymer and Process Engineering, Indian Institute of Technology Roorkee, Saharanpur Campus, Paper Mill Road, Saharanpur 247 001, Uttar Pradesh, India
| | - Sangram K. Samal
- Materials Research Centre, Indian Institute of Science, Bangalore 560 012, India
| |
Collapse
|
36
|
Caraher MC, Sophocleous A, Beattie JR, O'Driscoll O, Cummins NM, Brennan O, O'Brien FJ, Ralston SH, Bell SE, Towler M, Idris AI. Raman spectroscopy predicts the link between claw keratin and bone collagen structure in a rodent model of oestrogen deficiency. Biochim Biophys Acta Mol Basis Dis 2018; 1864:398-406. [DOI: 10.1016/j.bbadis.2017.10.020] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 09/21/2017] [Accepted: 10/16/2017] [Indexed: 12/25/2022]
|
37
|
Zhang C, Winnard PT, Dasari S, Kominsky SL, Doucet M, Jayaraman S, Raman V, Barman I. Label-free Raman spectroscopy provides early determination and precise localization of breast cancer-colonized bone alterations. Chem Sci 2017; 9:743-753. [PMID: 29629144 PMCID: PMC5869989 DOI: 10.1039/c7sc02905e] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Accepted: 11/14/2017] [Indexed: 12/13/2022] Open
Abstract
Raman spectral markers offer new routes to recognition of biomolecular alterations at sites of nascent and progressing metastatic cancer in bone.
Breast neoplasms frequently colonize bone and induce development of osteolytic bone lesions by disrupting the homeostasis of the bone microenvironment. This degenerative process can lead to bone pain and pathological bone fracture, a major cause of cancer morbidity and diminished quality of life, which is exacerbated by our limited ability to monitor early metastatic disease in bone and assess fracture risk. Spurred by its label-free, real-time nature and its exquisite molecular specificity, we employed spontaneous Raman spectroscopy to assess and quantify early metastasis driven biochemical alterations to bone composition. As early as two weeks after intracardiac inoculations of MDA-MB-435 breast cancer cells in NOD-SCID mice, Raman spectroscopic measurements in the femur and spine revealed consistent changes in carbonate substitution, overall mineralization as well as crystallinity increase in tumor-bearing bones when compared with their normal counterparts. Our observations reveal the possibility of early stage detection of biochemical changes in the tumor-bearing bones – significantly before morphological variations are captured through radiographic diagnosis. This study paves the way for a better molecular understanding of altered bone remodeling in such metastatic niches, and for further clinical studies with the goal of establishing a non-invasive tool for early metastasis detection and prediction of pathological fracture risk in breast cancer.
Collapse
Affiliation(s)
- Chi Zhang
- Department of Mechanical Engineering , Johns Hopkins University , Whiting School of Engineering , Latrobe Hall 103 , Baltimore , MD 21218 , USA . ; Tel: +1-410-516-0656
| | - Paul T Winnard
- Division of Cancer Imaging Research , Russell H. Morgan Department of Radiology and Radiological Science , Johns Hopkins University School of Medicine , 720 Rutland Avenue, Rm 340 Traylor Building , Baltimore , MD , USA 21205 . ; Tel: +1-410-955-7492
| | - Sidarth Dasari
- Indiana University School of Medicine , Indianapolis , IN , USA
| | - Scott L Kominsky
- Department of Orthopaedic Surgery , Johns Hopkins University School of Medicine , Baltimore , MD , USA
| | - Michele Doucet
- Department of Orthopaedic Surgery , Johns Hopkins University School of Medicine , Baltimore , MD , USA
| | - Swaathi Jayaraman
- Department of Orthopaedic Surgery , Johns Hopkins University School of Medicine , Baltimore , MD , USA
| | - Venu Raman
- Division of Cancer Imaging Research , Russell H. Morgan Department of Radiology and Radiological Science , Johns Hopkins University School of Medicine , 720 Rutland Avenue, Rm 340 Traylor Building , Baltimore , MD , USA 21205 . ; Tel: +1-410-955-7492.,Department of Oncology , Johns Hopkins University School of Medicine , Baltimore , MD , USA
| | - Ishan Barman
- Department of Mechanical Engineering , Johns Hopkins University , Whiting School of Engineering , Latrobe Hall 103 , Baltimore , MD 21218 , USA . ; Tel: +1-410-516-0656.,Department of Oncology , Johns Hopkins University School of Medicine , Baltimore , MD , USA
| |
Collapse
|
38
|
Makowski AJ, Granke M, Ayala OD, Uppuganti S, Mahadevan-Jansen A, Nyman JS. Applying Full Spectrum Analysis to a Raman Spectroscopic Assessment of Fracture Toughness of Human Cortical Bone. APPLIED SPECTROSCOPY 2017; 71:2385-2394. [PMID: 28708001 PMCID: PMC5561524 DOI: 10.1177/0003702817718149] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A decline in the inherent quality of bone tissue is a † Equal contributors contributor to the age-related increase in fracture risk. Although this is well-known, the important biochemical factors of bone quality have yet to be identified using Raman spectroscopy (RS), a nondestructive, inelastic light-scattering technique. To identify potential RS predictors of fracture risk, we applied principal component analysis (PCA) to 558 Raman spectra (370-1720 cm-1) of human cortical bone acquired from 62 female and male donors (nine spectra each) spanning adulthood (age range = 21-101 years). Spectra were analyzed prior to R-curve, nonlinear fracture mechanics that delineate crack initiation (Kinit) from crack growth toughness (Kgrow). The traditional ν1phosphate peak per amide I peak (mineral-to-matrix ratio) weakly correlated with Kinit (r = 0.341, p = 0.0067) and overall crack growth toughness (J-int: r = 0.331, p = 0.0086). Sub-peak ratios of the amide I band that are related to the secondary structure of type 1 collagen did not correlate with the fracture toughness properties. In the full spectrum analysis, one principal component (PC5) correlated with all of the mechanical properties (Kinit: r = - 0.467, Kgrow: r = - 0.375, and J-int: r = - 0.428; p < 0.0067). More importantly, when known predictors of fracture toughness, namely age and/or volumetric bone mineral density (vBMD), were included in general linear models as covariates, several PCs helped explain 45.0% (PC5) to 48.5% (PC7), 31.4% (PC6), and 25.8% (PC7) of the variance in Kinit, Kgrow, and J-int, respectively. Deriving spectral features from full spectrum analysis may improve the ability of RS, a clinically viable technology, to assess fracture risk.
Collapse
Affiliation(s)
- Alexander J. Makowski
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
| | - Mathilde Granke
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
| | - Oscar D. Ayala
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
| | - Anita Mahadevan-Jansen
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
| | - Jeffry S. Nyman
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
- Vanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN 37232
| |
Collapse
|
39
|
Raman Plus X: Biomedical Applications of Multimodal Raman Spectroscopy. SENSORS 2017; 17:s17071592. [PMID: 28686212 PMCID: PMC5539739 DOI: 10.3390/s17071592] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 07/04/2017] [Accepted: 07/04/2017] [Indexed: 12/11/2022]
Abstract
Raman spectroscopy is a label-free method of obtaining detailed chemical information about samples. Its compatibility with living tissue makes it an attractive choice for biomedical analysis, yet its translation from a research tool to a clinical tool has been slow, hampered by fundamental Raman scattering issues such as long integration times and limited penetration depth. In this review we detail the how combining Raman spectroscopy with other techniques yields multimodal instruments that can help to surmount the translational barriers faced by Raman alone. We review Raman combined with several optical and non-optical methods, including fluorescence, elastic scattering, OCT, phase imaging, and mass spectrometry. In each section we highlight the power of each combination along with a brief history and presentation of representative results. Finally, we conclude with a perspective detailing both benefits and challenges for multimodal Raman measurements, and give thoughts on future directions in the field.
Collapse
|
40
|
Smith SJ, Emery R, Pitsillides A, Clarkin CE, Mahajan S. Detection of early osteogenic commitment in primary cells using Raman spectroscopy. Analyst 2017; 142:1962-1973. [DOI: 10.1039/c6an02469f] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Raman spectroscopy as a simple and sensitive method to measure early osteogenic responses in primary cultures of bone cells is presented.
Collapse
Affiliation(s)
| | - Roger Emery
- Division of Surgery
- Reproductive Biology and Anaesthetics
- Imperial College London
- UK
| | | | | | - Sumeet Mahajan
- Department of Chemistry and the Institute for Life Sciences
- University of Southampton
- UK
| |
Collapse
|
41
|
Sowoidnich K, Churchwell JH, Buckley K, Goodship AE, Parker AW, Matousek P. Spatially offset Raman spectroscopy for photon migration studies in bones with different mineralization levels. Analyst 2017; 142:3219-3226. [DOI: 10.1039/c7an00408g] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
This study provides a deeper understanding of bone's optical properties which is essential to the development of SORS-based diagnostic tools.
Collapse
Affiliation(s)
- Kay Sowoidnich
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - John H. Churchwell
- UCL Institute of Orthopaedics and Musculoskeletal Science
- Royal National Orthopaedic Hospital
- London HA7 4LP
- UK
| | - Kevin Buckley
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - Allen E. Goodship
- UCL Institute of Orthopaedics and Musculoskeletal Science
- Royal National Orthopaedic Hospital
- London HA7 4LP
- UK
| | - Anthony W. Parker
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - Pavel Matousek
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| |
Collapse
|
42
|
Liao Z, Sinjab F, Nommeots-Nomm A, Jones J, Ruiz-Cantu L, Yang J, Rose F, Notingher I. Feasibility of Spatially Offset Raman Spectroscopy for in Vitro and in Vivo Monitoring Mineralization of Bone Tissue Engineering Scaffolds. Anal Chem 2016; 89:847-853. [PMID: 27983789 DOI: 10.1021/acs.analchem.6b03785] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
We investigated the feasibility of using spatially offset Raman spectroscopy (SORS) for nondestructive characterization of bone tissue engineering scaffolds. The deep regions of these scaffolds, or scaffolds implanted subcutaneously in live animals, are typically difficult to measure by confocal Raman spectroscopy techniques because of the limited depth penetration of light caused by the high level of light scattering. Layered samples consisting of bioactive glass foams (IEIC16), three-dimensional (3D)-printed biodegradable poly(lactic-co-glycolic acid) scaffolds (PLGA), and hydroxyapatite powder (HA) were used to mimic nondestructive detection of biomineralization for intact real-size 3D tissue engineering constructs. SORS spectra were measured with a new SORS instrument using a digital micromirror device (DMD) to allow software selection of the spatial offsets. The results show that HA can be reliably detected at depths of 0-2.3 mm, which corresponds to the maximum accessible spatial offset of the current instrument. The intensity ratio of Raman bands associated with the scaffolds and HA with the spatial offset depended on the depth at which HA was located. Furthermore, we show the feasibility for in vivo monitoring mineralization of scaffold implanted subcutaneously by demonstrating the ability to measure transcutaneously Raman signals of the scaffolds and HA (fresh chicken skin used as a top layer). The ability to measure spectral depth profiles at high speed (5 s acquisition time) and the ease of implementation make SORS a promising approach for noninvasive characterization of cell/tissue development in vitro, and for long-term in vivo monitoring the mineralization in 3D scaffolds subcutaneously implanted in small animals.
Collapse
Affiliation(s)
- Zhiyu Liao
- School of Physics and Astronomy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| | - Faris Sinjab
- School of Physics and Astronomy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| | - Amy Nommeots-Nomm
- Department of Materials, Imperial College London , SW7 2AZ, London, United Kingdom
| | - Julian Jones
- Department of Materials, Imperial College London , SW7 2AZ, London, United Kingdom
| | - Laura Ruiz-Cantu
- School of Pharmacy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| | - Jing Yang
- School of Pharmacy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| | - Felicity Rose
- School of Pharmacy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| | - Ioan Notingher
- School of Physics and Astronomy, University of Nottingham , University Park, Nottingham NG7 2RD, United Kingdom
| |
Collapse
|
43
|
Pascart T, Cortet B, Olejnik C, Paccou J, Migaud H, Cotten A, Delannoy Y, During A, Hardouin P, Penel G, Falgayrac G. Bone Samples Extracted from Embalmed Subjects Are Not Appropriate for the Assessment of Bone Quality at the Molecular Level Using Raman Spectroscopy. Anal Chem 2016; 88:2777-83. [DOI: 10.1021/acs.analchem.5b04400] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Tristan Pascart
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
- Department
of Rheumatology, Saint-Philibert Hospital, Lille University, 59160 Lomme, France
| | - Bernard Cortet
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
| | - Cecile Olejnik
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
| | - Julien Paccou
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
| | - Henri Migaud
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
| | - Anne Cotten
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
| | - Yann Delannoy
- Lille University − ULCO, PMOI, EA 4490, 59000 Lille, France
- Lille University, Taphonomy Unit, EA 7367, 59000 Lille, France
| | | | | | | | | |
Collapse
|
44
|
Matousek P, Stone N. Development of deep subsurface Raman spectroscopy for medical diagnosis and disease monitoring. Chem Soc Rev 2016; 45:1794-802. [DOI: 10.1039/c5cs00466g] [Citation(s) in RCA: 124] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The advent of non-invasive deep Raman techniques heralds the emergence of novel diagnostic and disease monitoring methods.
Collapse
Affiliation(s)
- Pavel Matousek
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Harwell Oxford
- UK
| | | |
Collapse
|
45
|
A Bone Sample Containing a Bone Graft Substitute Analyzed by Correlating Density Information Obtained by X-ray Micro Tomography with Compositional Information Obtained by Raman Microscopy. MATERIALS 2015; 8:3831-3853. [PMID: 28793410 PMCID: PMC5455664 DOI: 10.3390/ma8073831] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 05/26/2015] [Accepted: 06/15/2015] [Indexed: 11/29/2022]
Abstract
The ability of bone graft substitutes to promote new bone formation has been increasingly used in the medical field to repair skeletal defects or to replace missing bone in a broad range of applications in dentistry and orthopedics. A common way to assess such materials is via micro computed tomography (µ-CT), through the density information content provided by the absorption of X-rays. Information on the chemical composition of a material can be obtained via Raman spectroscopy. By investigating a bone sample from miniature pigs containing the bone graft substitute Bio Oss®, we pursued the target of assessing to what extent the density information gained by µ-CT imaging matches the chemical information content provided by Raman spectroscopic imaging. Raman images and Raman correlation maps of the investigated sample were used in order to generate a Raman based segmented image by means of an agglomerative, hierarchical cluster analysis. The resulting segments, showing chemically related areas, were subsequently compared with the µ-CT image by means of a one-way ANOVA. We found out that to a certain extent typical gray-level values (and the related histograms) in the µ-CT image can be reliably related to specific segments within the image resulting from the cluster analysis.
Collapse
|