1
|
Yang L, Sun H, Wang X, Yao W, Zhang W, Jiang L. An aptamer based aggregation assay for the neonicotinoid insecticide acetamiprid using fluorescent upconversion nanoparticles and DNA functionalized gold nanoparticles. Mikrochim Acta 2019; 186:308. [PMID: 31030275 DOI: 10.1007/s00604-019-3422-9] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Accepted: 04/08/2019] [Indexed: 12/14/2022]
Abstract
An acetamiprid-binding aptamer (ABA), gold nanoparticles (AuNPs) and upconversion nanoparticles (UCNPs) are used in a colorimetric and fluorometric method for the ultrasensitive and selective detection of the pesticide acetamiprid. The ABA is first configured into a duplex with a complementary DNA covalently attached to AuNPs. The resulting dsDNA-functionalized AuNP probe is not stable in 0.15 M NaCl solution and aggregates. This causing the color to change from red to purple. In the presence of acetamiprid, the ABA undergoes a structural switch from a DNA duplex to an aptamer-acetamiprid complex and consequently dissociates from the AuNPs. The partially unhybridized AuNPs are stable against salt-induced aggregation and show red color. The ratio of absorbances at 524 nm (red) and 650 nm (purple blue) varies with the concentration of acetamiprid in the 0.025-10 μM concentration range. The colorimetric signal can be further amplified by introducing DNA-modified carboxylated UCNPs (silica-coated NaYF4:Yb,Er) which display red and green fluorescence under 980 nm excitation. An inner filter effect occurs between DNA-modified UCNPs and dsDNA-modified AuNPs. The fluorometric assay is based on the measurement of the ratio of red (654 nm) and green (540 nm) fluorescence and works in the 0.025 to 1 μM acetamiprid concentration range and has a 0.36 nM detection limit (at a signal-to-noise ratio of 3). Because of the specificity of the aptamer, the assay is high selective. It was successfully used to quantify acetamiprid in contaminated real samples. Graphical abstract Schematic presentation of an upconversion fluorescent assay for acetamiprid. It involves the principle of analyte-triggered structural switch of aptamers, salt-induced AuNP aggregation, and signal amplification from UCNP.
Collapse
Affiliation(s)
- Limin Yang
- State Key Laboratory of Heavy Oil Processing and Center for Bioengineering and Biotechnology, China University of Petroleum (East China), Qingdao, Shandong, 266580, People's Republic of China
| | - Haifeng Sun
- State Key Laboratory of Heavy Oil Processing and Center for Bioengineering and Biotechnology, China University of Petroleum (East China), Qingdao, Shandong, 266580, People's Republic of China
| | - Xuan Wang
- State Key Laboratory of Heavy Oil Processing and Center for Bioengineering and Biotechnology, China University of Petroleum (East China), Qingdao, Shandong, 266580, People's Republic of China
| | - Weijing Yao
- Center for Evidence Identification, Chongqing Public Security Bureau, Chongqing, 401147, People's Republic of China
| | - Wenjuan Zhang
- State Key Laboratory of Heavy Oil Processing and Center for Bioengineering and Biotechnology, China University of Petroleum (East China), Qingdao, Shandong, 266580, People's Republic of China
| | - Lei Jiang
- State Key Laboratory of Heavy Oil Processing and Center for Bioengineering and Biotechnology, China University of Petroleum (East China), Qingdao, Shandong, 266580, People's Republic of China.
| |
Collapse
|
2
|
Dziomba S, Biernacki M, Olędzka I, Skrzydlewska E, Bączek T, Kowalski P. Repetitive injection field-amplified sample stacking for cationic compounds determination. Talanta 2014; 125:1-6. [DOI: 10.1016/j.talanta.2014.02.045] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 02/14/2014] [Accepted: 02/20/2014] [Indexed: 10/25/2022]
|
3
|
Gañan J, Morante-Zarcero S, Sierra I. Influence of Organic Modifier Additives to Separate Steroids by Micellar Electrokinetic Chromatography: Determination of Solute-Micelle Association Constants at Different Acetonitrile Concentrations. ANAL LETT 2014. [DOI: 10.1080/00032719.2013.874015] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
4
|
Li PH, Lin JY, Chen CT, Ciou WR, Chan PH, Luo L, Hsu HY, Diau EWG, Chen YC. Using gold nanoclusters as selective luminescent probes for phosphate-containing metabolites. Anal Chem 2012; 84:5484-8. [PMID: 22762258 DOI: 10.1021/ac300332t] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Glutathione-bound gold nanoclusters (AuNCs@GSH) can emit reddish photoluminescence under illumination of ultraviolet light. The luminescence of the AuNCs@GSH is quenched when chelating with iron ions (AuNCs@GSH-Fe(3+)), presumably resulting from the effective electron transfer between the nanoclusters and iron ions. Nevertheless, we found that the luminescence of the gold nanoclusters can be restored in the presence of phosphate-containing molecules, which suggested the possibility of using AuNCs@GSH-Fe(3+) complexes as the selective luminescent switches for phosphate-containing metabolites. Phosphate-containing metabolites such as adenosine-5'-triphosphate (ATP) and pyrophosphate play an important role in biological systems. In this study, we demonstrated that the luminescence of the AuNCs@GSH-Fe(3+) is switched-on when mixing with ATP and pyrophosphate, which can readily be observed by the naked eye. It results from the high formation constants between phosphates and iron ions. When employing fluorescence spectroscopy as the detection tool, quantitative analysis for phosphate-containing metabolites such as ATP and pyrophosphate can be conducted. The linear range for ATP and pyrophosphate is 50 μM to sub-millimolar, while the limit of detection for ATP and pyrophosphate are ∼43 and ∼28 μM, respectively. Additionally, we demonstrated that the luminescence of the AuNCs@GSH-Fe(3+) can also be turned on in the presence of phosphate-containing metabolites from cell lysates and blood plasma.
Collapse
Affiliation(s)
- Po-Han Li
- Department of Applied Chemistry, National Chiao Tung University, Hsinchu 300, Taiwan
| | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Kartsova LA, Bessonova EA. Preconcentration techniques in capillary electrophoresis. JOURNAL OF ANALYTICAL CHEMISTRY 2009. [DOI: 10.1134/s1061934809040029] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
6
|
Zhang H, Zhou L, Chen X. Improving sensitivity by large-volume sample stacking combined with sweeping without polarity switching by capillary electrophoresis coupled to photodiode array ultraviolet detection. Electrophoresis 2008; 29:1556-64. [DOI: 10.1002/elps.200700759] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
7
|
Simpson SL, Quirino JP, Terabe S. On-line sample preconcentration in capillary electrophoresis. J Chromatogr A 2008; 1184:504-41. [DOI: 10.1016/j.chroma.2007.11.001] [Citation(s) in RCA: 269] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2007] [Revised: 10/30/2007] [Accepted: 11/01/2007] [Indexed: 02/06/2023]
|
8
|
Amundsen LK, Kokkonen JT, Sirén H. Comparison of partial filling MEKC analyses of steroids with use of ESI-MS and UV spectrophotometry. J Sep Sci 2008; 31:803-13. [DOI: 10.1002/jssc.200700657] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Silva CA, Pereira EA, Micke GA, Farah JPS, Tavares MFM. Mixture-designed electrolytes for the MEKC separation of natural and synthetic steroids. Electrophoresis 2008; 28:3722-30. [PMID: 17941121 DOI: 10.1002/elps.200700511] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this work, the separation of 11 natural and synthetic steroids was studied using MEKC electrolytes modified by property-selected organic solvents: ethanol, ACN, and THF. The interplay between electrophoretic behavior and structural features was disclosed and the effects of organic modifiers to modulate retention and to alter selectivity were discussed in terms of system linear solvation energy relationships (LSER). The LSER indicated the total organic solvent percentage in the electrolyte as a major parameter to control retention and as a minor contribution, the hydrogen bond acidity. By evaluating the electropherograms obtained from mixture-designed electrolytes, a favorable separation condition for all solutes was achieved in ca. 25 min with an electrolyte composed of 20 mmol/L sodium tetraborate at pH 9.4, 20 mmol/L SDS and 20% EtOH (0.80% CV for migration time and 2.5% CV for peak area, n = five consecutive injections). The applicability of the proposed separation condition was demonstrated by the inspection of estrogens in urine sample (puberty stage).
Collapse
Affiliation(s)
- Claudinei A Silva
- Institute of Chemistry, University of São Paulo, São Paulo, SP, Brazil
| | | | | | | | | |
Collapse
|
10
|
Amundsen LK, Nevanen TK, Takkinen K, Rovio S, Sirén H. Microscale immunoaffinity SPE and MEKC in fast determination of testosterone in male urine. Electrophoresis 2007; 28:3232-41. [PMID: 17722186 DOI: 10.1002/elps.200700037] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Conventional methods for the determination of testosterone in body fluids typically suffer from poor recovery, lack of specificity, complex sample pretreatment, or the need for derivatization. Here, a simple, specific, and fast analysis method for testosterone was developed, with a methodology based on testosterone-specific immunoaffinity SPE (IA-SPE) and subsequent analysis by partial filling MEKC (PF-MEKC). An immunosorbent consisting of a recombinant antitestosterone Fab fragment covalently attached to activated Sepharose was prepared. IA-SPE and PF-MEKC were set up in hyphenated and off-line constructions, and the applicability of the two constructions in analysis of testosterone in male urine was investigated. The results obtained with the hyphenated construction proved to be only indicative of the presence of testosterone. The off-line IA-SPE and PF-MEKC construction, however, was successfully used in the determination of free testosterone in male urine samples after enzymatic hydrolysis of the glucuronide conjugates. Except for the hydrolysis reaction, no sample pretreatment was required. After hydrolysis, the overall analysis time per sample was only 14 min. The off-line IA-SPE and PF-MEKC method proved to be robust, sensitive (LOQ 35 mug/L), and specific, enabling separation of testosterone from four related steroids. Thus, it provides attractive features when compared to traditional methods for determination of testosterone in male urine.
Collapse
|
11
|
Malá Z, Krivánková L, Gebauer P, Bocek P. Contemporary sample stacking in CE: A sophisticated tool based on simple principles. Electrophoresis 2007; 28:243-53. [PMID: 17136738 DOI: 10.1002/elps.200600397] [Citation(s) in RCA: 125] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Sample stacking is a general term for methods in CE which are used for on-line concentration of diluted analytes. During the stacking process, analytes present at low concentrations in a long injected sample zone are concentrated into a short zone (stack). The stacked analytes are then separated and individual zones are detected. Thus stacking provides better separation efficiency and detection sensitivity. Many papers have been published on stacking till now, various procedures have been described, and, many names have been proposed for stacking procedures utilizing the same principles. This contribution brings an easy and unified view on stacking, describes the basic principles utilized, makes a list of recognized operational principles and brings an overview of principal current procedures. Further, it surveys selected recent practical applications ordered according to their operational principles and includes the terms, nicknames, and acronyms used for these actual stacking procedures. This contribution may help both newcomers and experts in the field of CE to orient themselves in the already quite complex topic of sample stacking.
Collapse
Affiliation(s)
- Zdena Malá
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic
| | | | | | | |
Collapse
|
12
|
Amundsen LK, Sirén H. Partial filling micellar electrokinetic chromatography analysis of androgens and testosterone derivatives using two sequential pseudostationary phases. J Chromatogr A 2006; 1131:267-74. [PMID: 16949594 DOI: 10.1016/j.chroma.2006.07.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2006] [Revised: 06/16/2006] [Accepted: 07/10/2006] [Indexed: 10/24/2022]
Abstract
Separation of anabolic and androgenic steroids by micellar electrokinetic chromatography (MEKC) has been little studied. Simultaneous separation of the endogenous alpha-epimers testosterone and epitestosterone has not been achieved with any electroseparation technique. Here, a partial filling micellar electrokinetic chromatographic (PF-MEKC) method is described for the analysis of three endogenous steroid hormones (androstenedione, testosterone, epitestosterone) and two synthetic anabolic steroids (fluoxymesterone, methyltestosterone). The resolution efficiency of single-isomer sulphated gamma-cyclodextrins and the surfactants sodium dodecyl sulphate and sodium taurocholate was exploited. The method is based on the sequential introduction of short plugs of two different pseudostationary phases into the capillary. The separation was completed in less than 10 min. The method can be used in quantitative analysis. Linear correlation was obtained between concentration and peak area of 0.996 or better. The repeatability (RSD) of the compound peak areas ranged from 3.6% (methyltestosterone) to 6.2% (androstenedione). Limits of detection were between 73 microg/L (testosterone) and 160 microg/L (fluoxymesterone). As a demonstration of the method, androstenedione, testosterone and epitestosterone were determined in a spiked urine sample.
Collapse
|