1
|
Fu SQ, Wang BD, Li YC, Huang ZX, Shi ZW, Zuo GF, Zhao JJ, Xu HJ, Wang MM. Ecofriendly and biocompatible biochars derived from waste-branches for direct and efficient solid-phase extraction of benzodiazepines in crude urine sample prior to LC-MS/MS. Mikrochim Acta 2025; 192:66. [PMID: 39792280 DOI: 10.1007/s00604-024-06912-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2024] [Accepted: 12/18/2024] [Indexed: 01/12/2025]
Abstract
Biochars (BCs) derived from waste-branches of apple tree, grape tree, and oak were developed for direct solid-phase extraction (SPE) of five benzodiazepines (BZDs) in crude urine samples prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination. Scanning electron microscopy, elemental analyzer, X-ray diffractometry, N2 adsorption/desorption experiments, and Fourier transform infrared spectrometry characterizations revealed the existence of their mesoporous structure and numerous oxygen-containing functional groups. The obtained BCs not only possessed high affinity towards BZDs via π-π and hydrogen bond interactions, but also afforded the great biocompatibility of excluding interfering components from undiluted urine samples when using SPE adsorbents. Variables affecting SPE of target analytes were systematically optimized including pH, ionic strength, dilution ratio, washing solution, desorption solvent, and its volume. The method of BC-based SPE combined with LC-MS/MS exhibited a wide linear range of 0.03-100 ng/mL, a low detection limit of 0.01-0.08 ng/mL, and satisfactory recovery of 77.6-106% for the studied BZDs. Notably, this method allowed the possibility of direct loading of undiluted urine samples and avoided tedious filtration and dilution steps, which significantly simplified the pretreatment process. Additionally, these BC sorbents derived from waste-branches were ecofriendly and cost-effective, providing a sustainable alternative for the traditional SPE sorbents. Thus, the proposed method has promising application for ecofriendly, simple, efficient, and reliable monitoring of BZDs in urine samples.
Collapse
Affiliation(s)
- Shi-Qi Fu
- School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China
| | - Bing-Dan Wang
- School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China
| | - Yuan-Chun Li
- School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China
| | - Zhi-Xin Huang
- Tangshan Xinyanuo Biotechnology Co., Ltd, Tangshan, 063000, Hebei, China
| | - Zhao-Wei Shi
- Tangshan Xinyanuo Biotechnology Co., Ltd, Tangshan, 063000, Hebei, China
| | - Gui-Fu Zuo
- College of Materials Science and Engineering, North China University of Science and Technology, Tangshan, 063210, Hebei, China
| | - Jun-Jian Zhao
- Department of Clinical Laboratory, North China University of Science and Technology Affiliated Hospital, Tangshan, 063000, Hebei, China
| | - Hou-Jun Xu
- School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
| | - Man-Man Wang
- School of Public Health, Hebei Key Laboratory of Occupational Health and Safety for Coal Industry, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan, 063210, Hebei, China.
| |
Collapse
|
2
|
He W, Wang Y, Chen K. A real-world pharmacovigilance study of FDA adverse event reporting system events for diazepam. Front Pharmacol 2024; 15:1278442. [PMID: 38327980 PMCID: PMC10847318 DOI: 10.3389/fphar.2024.1278442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Accepted: 01/08/2024] [Indexed: 02/09/2024] Open
Abstract
Background: Diazepam, one of the benzodiazepines, is widely used clinically to treat anxiety, for termination of epilepsy, and for sedation. However, the reports of its adverse events (AEs) have been numerous, and even fatal complications have been reported. In this study, we investigated the AEs of diazepam based on real data from the U.S. Food and Drug Administration (FDA) adverse event reporting system (FAERS). Methods: Disproportionality in diazepam-associated AEs was assessed through the calculation of reporting odds ratios (RORs), proportional reporting ratios (PRRs), Bayesian confidence-propagation neural networks (BCPNNs), and gamma-Poisson shrinkage (GPS). Results: Among the 19,514,140 case reports in the FAERS database, 15,546 reports with diazepam as the "principal suspect (PS)" AEs were identified. Diazepam-induced AEs occurred targeting 27 system organ categories (SOCs). Based on four algorithms, a total of 391 major disproportionate preferred terms (PTs) were filtered out. Unexpectedly significant AEs such as congenital nystagmus, developmental delays, and rhabdomyolysis were noted, which were not mentioned in the drug insert. Conclusion: Our study identified potential signals of new AEs that could provide strong support for clinical monitoring and risk identification of diazepam.
Collapse
Affiliation(s)
- Weizhen He
- Department of Neurosurgery, Xiang’an Hospital of Xiamen University, Xia Men, Fujian, China
| | - Yang Wang
- Department of Ear Nose and Throat, Xiang’an Hospital of Xiamen University, Xia Men, Fujian, China
| | - Kaiqin Chen
- Department of Neurosurgery, Xiang’an Hospital of Xiamen University, Xia Men, Fujian, China
| |
Collapse
|
3
|
An J, Wang X, Song H, Zhao T, Ren H, Kang W, Dong Z, Niu L, Shi H. Simultaneous determination of four sedative-hypnotics in human urine based on dendritic structured magnetic nanomaterials. ARAB J CHEM 2022. [DOI: 10.1016/j.arabjc.2022.104363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
4
|
Urinary bio-monitoring of amphetamine derivatives by needle trap device packed with the zirconium-based metal-organic framework. Sci Rep 2022; 12:13702. [PMID: 35953701 PMCID: PMC9372183 DOI: 10.1038/s41598-022-17861-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 08/02/2022] [Indexed: 12/02/2022] Open
Abstract
In this research, zirconium-based metal–organic framework was utilized as a novel and efficient porous adsorbent for headspace extraction of Amphetamine, Methamphetamine, and Fenfluramine from the urine samples by a needle trap device (NTD). The Zr-UiO-66-PDC was electrosynthesized at the green conditions and characterized by various analyses such as FT-IR, XRD, FE-SEM, EDS, and elemental mapping techniques. Then, the effective parameters on the NTD efficiency such as salt content, pH, extraction/desorption temperature and time were evaluated and optimized by response surface methodology. The optimal extraction of amphetamine compounds was accomplished in 50 min at 70 ºC at the situation with NaCl content of 27% and pH: 11.90. The limit of detection, and limit of quantification factors were determined to be 0.06–0.09 and 0.5–0.8 ng mL−1, respectively. Furthermore, the precision and accuracy (intra- and inter-day) of the employed procedure in the term of relative standard deviation (RSD) were calculated in the range of 8.0–9.0% and 6.8–9.8%, respectively. Also, the recovery percent of the extracted analytes were concluded in the range of 95.0–97.0% after 10 days from the sampling and storage at 4 °C. Finally, the proposed procedure was involved in the analysis of amphetamine compounds in the real urine samples. These results were proved the proposed Zr-UiO-66-PDC@HS-NTD technique coupled with GC-FID can be used as an eco-friendly, fast-response, sensitive, and efficient drug test procedure for trace analysis of the amphetamine compounds in urine samples.
Collapse
|
5
|
Taherzade SD, Abbasichaleshtori M, Soleimannejad J. Efficient and ecofriendly cellulose-supported MIL-100(Fe) for wastewater treatment. RSC Adv 2022; 12:9023-9035. [PMID: 35424899 PMCID: PMC8985083 DOI: 10.1039/d1ra08949h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 03/15/2022] [Indexed: 11/21/2022] Open
Abstract
Due to their efficiency and accessibility, benzodiazepines are widely manufactured and consumed and as a result, they can be found in almost all wastewaters. Among the materials that were used for the removal of drug contaminants from wastewater, metal-organic frameworks (MOFs) demonstrated unique properties. In this regard, a composite of carboxymethylated cellulose (CMC) and MIL-100(Fe) was prepared via a sonochemical method and used for the removal of lorazepam from wastewater in various conditions. A maximum capacity of 811 mg g-1 was achieved which is considered a great improvement compared to bare MIL-100(Fe) (150 mg g-1) and other previously reported adsorbents. It is noteworthy that the efficiency of the adsorbent did not reduce in the second and third cycle of adsorption/desorption. Moreover, the effect of pH, dose of adsorbent, isotherms and the kinetics of this process were studied using UV-vis and HPLC analyses and the adsorbents were fully characterized with PXRD, TGA, BET, SEM, ZP and FT-IR techniques. Our findings demonstrate that this composite is clearly a green, recyclable and efficient adsorbent for the removal of lorazepam and opens our way to further potential applications in the removal of other active pharmaceutical ingredients.
Collapse
Affiliation(s)
- Seyed Dariush Taherzade
- School of Chemistry, College of Science, University of Tehran P. O. Box 14155-6455 Tehran Iran
| | | | - Janet Soleimannejad
- School of Chemistry, College of Science, University of Tehran P. O. Box 14155-6455 Tehran Iran
| |
Collapse
|
6
|
Facile Fabrication of Diatomite-Supported ZIF-8 Composite for Solid-Phase Extraction of Benzodiazepines in Urine Samples Prior to High-Performance Liquid Chromatography. Molecules 2021; 26:molecules26175209. [PMID: 34500641 PMCID: PMC8434582 DOI: 10.3390/molecules26175209] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/20/2021] [Accepted: 08/24/2021] [Indexed: 11/17/2022] Open
Abstract
A novel diatomite-supported zeolitic imidazolate framework-8 sorbent (ZIF-8@Dt-COOH) was in situ fabricated and developed for solid-phase extraction of three benzodiazepines (triazolam, midazolam and diazepam) in urine followed by high-performance liquid chromatography. ZIF-8@Dt-COOH was easily prepared by coating ZIF-8 on the surface of Dt-COOH and characterized by Fourier transform infrared spectra, X-ray powder diffractometry and scanning electron microscopy. Compared with bare Dt-COOH, the extraction efficiency of ZIF-8@Dt-COOH for the target was significantly increased from 20.1–39.0% to 100%. Main extraction parameters, including ionic strength and pH of solution, loading volume, washing solution, elution solvent and elution volume, were optimized in detail. Under optimum conditions, the developed method gave linearity of three BZDs in 2–500 ng/mL (r ≥ 0.9995). Limits of detection (S/N = 3), and limits of quantification (S/N = 10) were 0.3–0.4 ng/mL and 1.0–1.3 ng/mL, respectively. In addition, the average recoveries at three spiked levels (5, 10 and 20 ng/mL) varied from 80.0% to 98.7%, with the intra-day and inter-day precisions of 1.4–5.2% and 1.5–8.2%, respectively. The proposed method provided an effective purification performance and gave the enrichment factors of 24.0–29.6. The proposed method was successfully employed for the accurate and sensitive determination of benzodiazepines in urine.
Collapse
|
7
|
Abstract
The quantitative determination of xenobiotic compounds, as well as biotics in biological matrices, is generally described with the term bioanalysis. Due to the complexity of biofluids, in combination with the low concentration of the small molecules, their determination in biological matrices is a challenging procedure. Apart from the conventional solid-phase extraction, liquid-liquid extraction, protein precipitation, and direct injection approaches, nowadays, a plethora of microextraction and miniaturized extraction techniques have been reported. Furthermore, the development and evaluation of novel extraction adsorbents for sample preparation has become a popular research field. Metal-organic frameworks (MOFs) are novel materials composed of metal ions or clusters in coordination with organic linkers. Unequivocally, MOFs are gaining more and more attention in analytical chemistry due to their superior properties, including high surface area and tunability of pore size and functionality. This review discusses the utilization of MOFs in the sample preparation of biological samples for the green extraction of small organic molecules. Their common preparation and characterization strategies are discussed, while emphasis is given to their applications for green sample preparation.
Collapse
|
8
|
Yilmaz E, Sarp G, Uzcan F, Ozalp O, Soylak M. Application of magnetic nanomaterials in bioanalysis. Talanta 2021; 229:122285. [PMID: 33838779 DOI: 10.1016/j.talanta.2021.122285] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/04/2021] [Accepted: 02/26/2021] [Indexed: 12/21/2022]
Abstract
The importance of magnetic nanomaterials and magnetic hybrid materials, which are classified as new generation materials, in analytical applications is increasingly understood, and research on the adaptation of these materials to analytical methods has gained momentum. Development of sample preparation techniques and sensor systems using magnetic nanomaterials for the analysis of inorganic, organic and biomolecules in biological samples, which are among the samples that analytical chemists work on most, are among the priority issues. Therefore in this review, we focused on the use of magnetic nanomaterials for the bioanalytical applications including inorganic and organic species and biomolecules in different biological samples such as primarily blood, serum, plasma, tissue extracts, urine and milk. We summarized recent progresses, prevailing techniques, applied formats, and future trends in sample preparation-analysis methods and sensors based on magnetic nanomaterials (Mag-NMs). First, we provided a brief introduction of magnetic nanomaterials, especially their magnetic properties that can be utilized for bioanalytical applications. Second, we discussed the synthesis of these Mag-NMs. Third, we reviewed recent advances in bioanalytical applications of the Mag-NMs in different formats. Finally, recently literature studies on the relevance of Mag-NMs for bioanalysis applications were presented.
Collapse
Affiliation(s)
- Erkan Yilmaz
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkey; Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; ERNAM-Nanotechnology Application and Research Center, Erciyes University, Kayseri, Turkey
| | - Gokhan Sarp
- Department of Analytical Chemistry, Faculty of Pharmacy, Erciyes University, Kayseri, Turkey; Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; ERNAM-Nanotechnology Application and Research Center, Erciyes University, Kayseri, Turkey
| | - Furkan Uzcan
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey
| | - Ozgur Ozalp
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey
| | - Mustafa Soylak
- Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey; Department of Chemistry, Faculty of Sciences, Erciyes University, Kayseri, Turkey.
| |
Collapse
|
9
|
Bahrani S, Ghaedi M, Asfaram A, Mansoorkhani MJK, Javadian H. Rapid ultrasound-assisted microextraction of atorvastatin in the sample of blood plasma by nickel metal organic modified with alumina nanoparticles. J Sep Sci 2020; 43:4469-4479. [PMID: 33048447 DOI: 10.1002/jssc.202000660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/04/2020] [Accepted: 10/05/2020] [Indexed: 12/20/2022]
Abstract
In the present work, nickel-1,4-benzenedioxyacetic acid was synthesized as a rod-like metal organic material and then modified with alumina nanoparticles to synthesize nickel metal organic modified-Al2 O3 nanoparticles. The material was found as an efficient sorbent for the enrichment of atorvastatin in human blood plasma. After the extraction of the sample of plasma by ultrasound-assisted dispersive solid phase extraction, high performance liquid chromatography-ultraviolet was used to determine the quantitatively pre-concentrated interest analyte. The conditions for optimum extraction were achieved by the optimization of the volume of eluent, dosage of the sorbent, and time of sonication. Solution pH of 7.0, 250 μL of ethanol, 45 mg of the sorbent, and 10 min of sonication time were the conditions for extracting the atorvastatin maximum recovery of higher than 97.0%. By using desirability function for the optimization of the process, the present method showed a response that was linear ranging from 0.2 to 800 ng/mL with regression coefficient of 0.999 in the plasma of human blood with a satisfactory detection limit of 0.05 ng/mL, while the precision of interday for the current method was found to be <5%. It can be concluded that dispersive solid phase extraction method is effective for the extraction of atorvastatin from human plasma samples (97.4-102%) due to its easy operation, simplicity, repeatability, and reliability.
Collapse
Affiliation(s)
- Sonia Bahrani
- Department of Chemistry, Yasouj University, Yasuj, Iran
| | | | - Arash Asfaram
- Medicinal Plants Research Center, Yasuj University of Medical Sciences, Yasuj, Iran
| | | | - Hamedreza Javadian
- Universitat Politècnica de Catalunya, Department of Chemical Engineering, ETSEIB, Diagonal 647, Barcelona, Spain
| |
Collapse
|
10
|
Pérez-Cejuela HM, Herrero-Martínez JM, Simó-Alfonso EF. Recent Advances in Affinity MOF-Based Sorbents with Sample Preparation Purposes. Molecules 2020; 25:E4216. [PMID: 32938010 PMCID: PMC7571043 DOI: 10.3390/molecules25184216] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/01/2020] [Accepted: 09/10/2020] [Indexed: 02/07/2023] Open
Abstract
This review summarizes the recent advances concerning metal-organic frameworks (MOFs) modified with several biomolecules (e.g., amino acids, nucleobases, proteins, antibodies, aptamers, etc.) as ligands to prepare affinity-based sorbents for application in the sample preparation field. The preparation and incorporation strategies of these MOF-based affinity materials were described. Additionally, the different types of ligands that can be employed for the synthesis of these biocomposites and their application as sorbents for the selective extraction of molecules and clean-up of complex real samples is reported. The most important features of the developed biocomposites will be discussed throughout the text in different sections, and several examples will be also commented on in detail.
Collapse
Affiliation(s)
| | | | - Ernesto F. Simó-Alfonso
- Department of Analytical Chemistry, University of Valencia, C/Dr. Moliner, 50, 46100 Burjassot, Valencia, Spain; (H.M.P.-C.); (J.M.H.-M.)
| |
Collapse
|
11
|
Yang H, Li L, Cao H, Zhang Z, Zhao T, Hao Y, Wang M. Silica supported metal organic framework 808 composites as adsorbent for solid-phase extraction of benzodiazepines in urine sample. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105062] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
12
|
Zhao T, Du L, Zhang Z, Li N, Wang M, Ren Q. A poly(N,N-dimethylaminoethyl methacrylate-co-ethylene glycol dimethacrylate) monolith for direct solid-phase extraction of benzodiazepines from undiluted human urine. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3924-3932. [PMID: 32720657 DOI: 10.1039/d0ay01025a] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A novel polymeric monolith using N,N-dimethylaminoethyl methacrylate as the monomer and ethylene glycol dimethacrylate as the crosslinker was successfully synthesized in a syringe and applied for direct solid-phase extraction of four benzodiazepines (bromazepam, triazolam, midazolam and diazepam) from undiluted urine samples prior to high performance liquid chromatography. The monolith was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and nitrogen adsorption-desorption experiments. Moreover, extraction parameters, including loading, washing and eluting conditions were optimized. Under the optimized conditions, the proposed method obtained linear ranges of 2.0-500 ng mL-1 with correlation coefficients (r) higher than 0.9997. The limits of detection (S/N = 3) and limits of quantification (S/N = 10) were 0.4-0.6 ng mL-1 and 1.4-2.0 ng mL-1, respectively. The recoveries at three spiked levels ranged from 83.7% to 103% with the intra- and inter-day precisions from 0.6-7.6% to 2.7-9.8%. The present monolith allowed direct loading of crude urine samples without any filtration or dilution step. Besides, the sorbent offered an enhancement factor of 16.7-20.6 and was stable enough for ten replicate cycles of extraction/desorption of urine samples. The developed method presented an alternative strategy for the accurate and convenient determination of benzodiazepines in urine samples.
Collapse
Affiliation(s)
- Tengwen Zhao
- School of Public Health, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian, Tangshan 063210, Hebei, China.
| | | | | | | | | | | |
Collapse
|
13
|
Jones NS, Comparin JH. Interpol review of controlled substances 2016-2019. Forensic Sci Int Synerg 2020; 2:608-669. [PMID: 33385148 PMCID: PMC7770462 DOI: 10.1016/j.fsisyn.2020.01.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 01/23/2020] [Indexed: 12/14/2022]
Abstract
This review paper covers the forensic-relevant literature in controlled substances from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.int/content/download/14458/file/Interpol%20Review%20Papers%202019.pdf.
Collapse
Affiliation(s)
- Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
| | - Jeffrey H. Comparin
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| |
Collapse
|
14
|
Mohammadi F, Shabani AMH, Dadfarnia S, Ansari M, Asgharinezhad AA. Dispersive solid-phase extraction of buprenorphine from biological fluids using metal-organic frameworks and its determination by ultra-performance liquid chromatography. J Sep Sci 2020; 43:3045-3052. [PMID: 32415752 DOI: 10.1002/jssc.202000221] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 05/04/2020] [Accepted: 05/07/2020] [Indexed: 12/16/2022]
Abstract
In this work, various types of metal-organic frameworks were synthesized, and their affinities toward buprenorphine were evaluated using dispersive solid-phase extraction. The extracted buprenorphine was determined by ultra high performance liquid chromatography-ultraviolet detection system. The highest extraction recovery was observed by employing zeolitic imidazole framework-67. Then, a facile and fast extraction method was designed for the extraction and purification of the target drug. Optimization of the extraction method was carried out by the design of experiment approach. A linearity range of 1-1000 μg/L with the limit of detection of 0.15 μg/L and relative standard deviations (50 μg/L, n = 5) of 3.4% was obtained for standard sample analysis. Under optimized experimental and instrumental conditions, the relative recoveries were in the range of 95 to 111%. Eventually, zeolitic imidazole framework-67 was successfully employed for the extraction and determination of buprenorphine in the biological fluids with satisfactory results.
Collapse
Affiliation(s)
| | | | | | - Mehdi Ansari
- Department of Drug and Food Control, Faculty of Pharmacy, Kerman University of Medical Sciences, Kerman, Iran
| | | |
Collapse
|
15
|
|
16
|
Firoozichahak A, Bahrami A, Ghorbani Shahna F, Alizadeh S, Nematollahi D, Farhadian M. Development of a needle trap device packed with titanium-based metal-organic framework sorbent for extraction of phenolic derivatives in air. J Sep Sci 2019; 43:1011-1018. [PMID: 31854086 DOI: 10.1002/jssc.201900938] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 12/11/2019] [Accepted: 12/11/2019] [Indexed: 12/15/2022]
Abstract
We developed a novel method of needle trap device packed with titanium-based metal-organic framework for the extraction of phenolic derivatives in air followed by gas chromatography-flame ionization detector analysis. The synthetized adsorbent was packed inside a 22-gauge spinal needle. This method was first tested at laboratory scale, and then was used for field sampling of phenolic derivatives in air. A glass chamber placed on a heater at 60°C was used to provide different concentrations of phenolic derivatives. The desorption conditions and breakthrough volume were optimized using response surface methodology. The limit of detection and limit of quantitation of the proposed method were estimated to be in the range of 0.001-0.12 and 0.003-0.62 ng/mL, respectively, indicating a high sensitivity for the suggested sampler. Storing the packed needle trap device in a refrigerator at 4˚C for 60 days did not dramatically affect the storage stability. Our findings indicated that there was a high correlation coefficient (R2 = 0.99) between the measurement results of this method and the NIOSH recommended method (XAD-7 sorbent tube). Therefore, it can be concluded that the needle trap device packed with titanium-based metal-organic framework can be used as a efficient method for extraction of phenolic derivatives in air.
Collapse
Affiliation(s)
- Ali Firoozichahak
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Abdulrahman Bahrami
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Farshid Ghorbani Shahna
- Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Saber Alizadeh
- Department of Chemistry, Bu-Ali-Sina University, Hamedan, Iran
| | | | - Maryam Farhadian
- Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
| |
Collapse
|
17
|
|
18
|
Liu C, Wu S, Yan Y, Dong Y, Shen X, Huang C. Application of magnetic particles in forensic science. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115674] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
19
|
Abstract
Metal-organic frameworks (MOFs) are porous hybrid materials composed of metal ions and organic linkers, characterized by their crystallinity and by the highest known surface areas. MOFs structures present accessible cages, tunnels and modifiable pores, together with adequate mechanical and thermal stability. Their outstanding properties have led to their recognition as revolutionary materials in recent years. Analytical chemistry has also benefited from the potential of MOF applications. MOFs succeed as sorbent materials in extraction and microextraction procedures, as sensors, and as stationary or pseudo-stationary phases in chromatographic systems. To date, around 100 different MOFs form part of those analytical applications. This review intends to give an overview on the use of MOFs in analytical chemistry in recent years (2017–2019) within the framework of green analytical chemistry requirements, with a particular emphasis on possible toxicity issues of neat MOFs and trends to ensure green approaches in their preparation.
Collapse
|
20
|
Liu G, Huang X, Lu M, Li L, Li T, Xu D. Facile synthesis of magnetic zinc metal-organic framework for extraction of nitrogen-containing heterocyclic fungicides from lettuce vegetable samples. J Sep Sci 2019; 42:1451-1458. [PMID: 30677235 DOI: 10.1002/jssc.201801169] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2018] [Revised: 12/26/2018] [Accepted: 01/19/2019] [Indexed: 12/26/2022]
Abstract
We present a simple method for the fabrication of a magnetic amino-functionalized zinc metal-organic framework based on a magnetic graphene oxide composite. The resultant framework exhibited a porous 3D structure, high surface area and good adsorption properties for nitrogen-containing heterocyclic fungicides. The adsorption process and capacity indicated that the primary adsorption mechanism might be hydrogen bonding and π-π conjugation. In addition, an optimized protocol for magnetic solid phase extraction was developed (such as adsorbent content, pH, and desorption solvent), and utilized for the extraction of nitrogen-containing heterocyclic fungicides from vegetable samples. Quantitation by high performance liquid chromatography coupled with tandem mass spectrometry offered a detection limit of 0.21-1.0 μg/L (S/N = 3) with correlation coefficients larger than 0.9975. These results demonstrate that magnetic amino-functionalized zinc metal-organic framewor is a promising adsorbent for the extraction and quantitation of nitrogen-containing heterocyclic fungicides.
Collapse
Affiliation(s)
- Guangyang Liu
- Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing, P. R. China
| | - Xiaodong Huang
- Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing, P. R. China
| | - Meng Lu
- College of Life Sciences and Engineering, Hebei University of Engineering, Handan, P. R. China
| | - Lingyun Li
- Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing, P. R. China
| | - Tengfei Li
- College of Life Sciences and Engineering, Hebei University of Engineering, Handan, P. R. China
| | - Donghui Xu
- Institute of Vegetables and Flowers, Chinese Academy of Agricultural Sciences, Key Laboratory of Vegetables Quality and Safety Control, Ministry of Agriculture and Rural Affairs of China, Beijing, P. R. China
| |
Collapse
|