1
|
Li R, Ma M, Wang C, Hong J, Zhang Z, Lu J, Li P. Dual-exposure temporal laser speckle imaging for simultaneously accessing microvascular blood perfusion and angiography. OPTICS EXPRESS 2024; 32:6887-6902. [PMID: 38439384 DOI: 10.1364/oe.510874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 01/31/2024] [Indexed: 03/06/2024]
Abstract
Laser speckle contrast imaging (LSCI) has gained significant attention in the biomedical field for its ability to map the spatio-temporal dynamics of blood perfusion in vivo. However, LSCI faces difficulties in accurately resolving blood perfusion in microvessels. Although the transmissive detecting geometry can improve the spatial resolution of tissue imaging, ballistic photons directly transmitting forward through tissue without scattering will cause misestimating in the flow speed by LSCI because of the lack of a quantitative theoretical model of transmissvie LSCI. Here, we develop a model of temporal LSCI which accounts for the effect of nonscattered light on estimating decorrelation time. Based on this model, we further propose a dual-exposure temporal laser speckle imaging method (dEtLSCI) to correct the overestimation of background speed when performing traditional transmissive LSCI, and reconstruct microvascular angiography using the scattered component extracted from total transmitted light. Experimental results demonstrated that our new method opens an opportunity for LSCI to simultaneously resolve the blood vessels morphology and blood flow speed at microvascular level in various contexts, ranging from the drug-induced vascular response to angiogenesis and the blood perfusion monitoring during tumor growth.
Collapse
|
2
|
Youssef D, Fekry O, Badr A, Afify A, Hamed E. A new perspective on quantitative assessment of photodynamic therapy mediated hydrogel nanocomposite in wound healing using objective biospeckle and morphological local-gradient. Comput Biol Med 2023; 163:107196. [PMID: 37356291 DOI: 10.1016/j.compbiomed.2023.107196] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Revised: 06/03/2023] [Accepted: 06/19/2023] [Indexed: 06/27/2023]
Abstract
Skin wounding is a serious public health issue, especially when considering factors that accelerate tissue recovery. Consequently, the use of photodynamic therapy (PDT) as an effective wound-healing treatment has attracted more scientific attention. Although assessing the wound healing rate is crucial for appropriate monitoring of the probability of wound healing and evaluating the treatment efficiency, the currently used techniques lack the ability to provide such information. Therefore, this study has two aims, first, it contributes to the development of a new image-guided biospeckle system for quantitative monitoring of skin wound healing rate. Second, it evaluates the potential of using a novel synthesized PDT-mediated polyethylene glycol fabric with methylene blue (PEG-MB) hydrogel nanocomposite in accelerating wound healing. The proposed imaging system initially acquires raw biospeckle images from the wound regions of adult healthy albino mice treated with the synthesized hydrogel nanocomposite. Each raw biospeckle image is then converted into maps of morphological local-gradient matrices implemented from the combination of dilation and erosion operations at different radii up to 25 pixels. Subsequently, their intensity histogram statistics are computed, taking central moments as the feature set. Final characterization is achieved via a linear combination of the biospeckle statistics maintaining as much variance as possible using principal component analysis (PCA). The results confirmed by cytokine concentration measurement and histological investigation demonstrate that the innovative biospeckle image-guided system is ideal for investigating wound healing and suggest the potential of the hydrogel nanocomposite as an active dressing.
Collapse
Affiliation(s)
- Doaa Youssef
- Department of Engineering Applications of Lasers, National Institute of Laser Enhanced Sciences, Cairo University, Egypt.
| | - Osama Fekry
- Department of Medical Applications of Lasers, National Institute of Laser Enhanced Sciences, Cairo University, Egypt
| | - Abeer Badr
- Department of Zoology, Faculty of Science, Cairo University, Egypt
| | - Ahmed Afify
- Department of Zoology, Faculty of Science, Cairo University, Egypt
| | - Eman Hamed
- Department of Zoology, Faculty of Science, Cairo University, Egypt
| |
Collapse
|
3
|
Nam K, Mendoza FA, Wessner CE, Allawh TC, Forsberg F. Ultrasound quantitative assessment of ventral finger microvasculopathy in systemic sclerosis with Raynaud's phenomena: a comparative study. RMD Open 2023; 9:rmdopen-2022-002954. [PMID: 36787926 PMCID: PMC9930605 DOI: 10.1136/rmdopen-2022-002954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 02/01/2023] [Indexed: 02/16/2023] Open
Abstract
OBJECTIVE To assess the finger vascularity of systemic sclerosis patients with Raynaud's phenomenon (RP-SSc) using various ultrasound techniques. METHODS All fingers (except thumbs) of 18 RP-SSc patients and 18 controls were imaged at room temperature using four ultrasound vascular imaging techniques. The percent vascular area was quantified by counting blood flow pixels in a 25 mm2 square centred at the nail fold for the dorsal side and in 25 mm2 and 100 mm2 square from the fingertip for the ventral side. The mean vascular intensity was calculated from the corresponding areas for dorsal and ventral sides. RESULTS The percent vascular areas and mean vascular intensities in RP-SSc were significantly lower than those in controls for both dorsal and ventral sides (p<0.01). The mean vascular intensities showed slightly higher area under the curve (AUC) than the percent vascular areas (0.53-0.91 vs 0.53-0.90) regardless of imaging technique and assessment side. For each imaging technique, the ventral side vascularity showed a higher AUC (0.74-0.91) compared with the dorsal side (0.53-0.81). Moreover, ventral side abnormalities were associated with a history of digital ulcers. CONCLUSIONS Ultrasound demonstrated potential to quantify finger vascularity of RP-SSc. The ventral side of the fingers showed a higher accuracy in detecting RP-SSc than the dorsal side.
Collapse
Affiliation(s)
- Kibo Nam
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Fabian A Mendoza
- Department of Medicine, Division of Rheumatology and Jefferson Scleroderma Center, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Corinne E Wessner
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Tanya C Allawh
- Department of Medicine, Division of Rheumatology and Jefferson Scleroderma Center, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Flemming Forsberg
- Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
4
|
Nwaiwu CA, Buharin VE, Mach A, Grandl R, King ML, Dechert AF, O'Shea L, Schwaitzberg SD, Kim PCW. Feasibility and comparison of laparoscopic laser speckle contrast imaging to near-infrared display of indocyanine green in intraoperative tissue blood flow/tissue perfusion in preclinical porcine models. Surg Endosc 2023; 37:1086-1095. [PMID: 36114346 DOI: 10.1007/s00464-022-09583-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 08/25/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To determine if laser speckle contrast imaging (LSCI) mitigates variations and subjectivity in the use and interpretation of indocyanine green (ICG) fluorescence in the current visualization paradigm of real-time intraoperative tissue blood flow/perfusion in clinically relevant scenarios. METHODS De novo laparoscopic imaging form-factor detecting real-time blood flow using LSCI and blood volume by near-infrared fluorescence (NIRF) of ICG was compared to ICG NIRF alone, for dye-less real-time visualization of tissue blood flow/perfusion. Experienced surgeons examined LSCI and ICG in segmentally devascularized intestine, partial gastrectomy, and the renal hilum across six porcine models. Precision and accuracy of identifying demarcating lines of ischemia/perfusion in tissues were determined in blinded subjects with varying levels of surgical experience. RESULTS Unlike ICG, LSCI perfusion detection was real time (latency < 150 ms: p < 0.01), repeatable and on-demand without fluorophore injection. Operating surgeons (n = 6) precisely and accurately identified concordant demarcating lines in white light, LSCI, and ICG modes immediately. Blinded subjects (n = 21) demonstrated similar spatial-temporal precision and accuracy with all three modes ≤ 2 min after ICG injection, and discordance in ICG mode at ≥ 5 min in devascularized small intestine (p < 0.0001) and in partial gastrectomy (p < 0.0001). CONCLUSIONS Combining LSCI for near real-time blood flow detection with ICG fluorescence for blood volume detection significantly improves precision and accuracy of perfusion detection in tissue locations over time, in real time, and repeatably on-demand than ICG alone.
Collapse
Affiliation(s)
- Chibueze A Nwaiwu
- Department of Surgery, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI, USA
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Vasiliy E Buharin
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Anderson Mach
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Robin Grandl
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Matthew L King
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Alyson F Dechert
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | - Liam O'Shea
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA
| | | | - Peter C W Kim
- Department of Surgery, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI, USA.
- Activ Surgical Inc, 30 Thomson Place, 2nd Floor, Boston, MA, 02127, USA.
| |
Collapse
|
5
|
Wearable, wireless, multi-sensor device for monitoring tissue circulation after free-tissue transplantation: a multicentre clinical trial. Sci Rep 2022; 12:16532. [PMID: 36192423 PMCID: PMC9529918 DOI: 10.1038/s41598-022-21007-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 09/21/2022] [Indexed: 12/05/2022] Open
Abstract
Wearable sensors have seen remarkable recent technological developments, and their role in healthcare is expected to expand. Specifically, monitoring tissue circulation in patients who have undergone reconstructive surgery is critical because blood flow deficiencies must be rescued within hours or the transplant will fail due to thrombosis/haematoma within the artery or vein. We design a wearable, wireless, continuous, multipoint sensor to monitor tissue circulation. The system measures pulse waves, skin colour, and tissue temperature to reproduce physician assessment. Data are analysed in real time for patient risk using an algorithm. This multicentre clinical trial involved 73 patients who underwent transplant surgery and had their tissue circulation monitored until postoperative day 7. Herein, we show that the overall agreement rate between physician and sensor findings is 99.2%. In addition, the patient questionnaire results indicate that the device is easy to wear. The sensor demonstrates non-invasive, real-time, continuous, multi-point, wireless, and reliable monitoring for postoperative care. This wearable system can improve the success rate of reconstructive surgeries.
Collapse
|
6
|
Li DY, Xia Q, Yu TT, Zhu JT, Zhu D. Transmissive-detected laser speckle contrast imaging for blood flow monitoring in thick tissue: from Monte Carlo simulation to experimental demonstration. LIGHT, SCIENCE & APPLICATIONS 2021; 10:241. [PMID: 34862369 PMCID: PMC8642418 DOI: 10.1038/s41377-021-00682-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 10/20/2021] [Accepted: 11/23/2021] [Indexed: 05/04/2023]
Abstract
Laser speckle contrast imaging (LSCI) is a powerful tool to monitor blood flow distribution and has been widely used in studies of microcirculation, both for animal and clinical applications. Conventionally, LSCI usually works on reflective-detected mode. However, it could provide promising temporal and spatial resolution for in vivo applications only with the assistance of various tissue windows, otherwise, the overlarge superficial static speckle would extremely limit its contrast and resolution. Here, we systematically investigated the capability of transmissive-detected LSCI (TR-LSCI) for blood flow monitoring in thick tissue. Using Monte Carlo simulation, we theoretically compared the performance of transmissive and reflective detection. It was found that the reflective-detected mode was better when the target layer was at the very surface, but the imaging quality would rapidly decrease with imaging depth, while the transmissive-detected mode could obtain a much stronger signal-to-background ratio (SBR) for thick tissue. We further proved by tissue phantom, animal, and human experiments that in a certain thickness of tissue, TR-LSCI showed remarkably better performance for thick-tissue imaging, and the imaging quality would be further improved if the use of longer wavelengths of near-infrared light. Therefore, both theoretical and experimental results demonstrate that TR-LSCI is capable of obtaining thick-tissue blood flow information and holds great potential in the field of microcirculation research.
Collapse
Affiliation(s)
- Dong-Yu Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
- MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
| | - Qing Xia
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
- MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
| | - Ting-Ting Yu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
- MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
| | - Jing-Tan Zhu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
- MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China
| | - Dan Zhu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China.
- MoE Key Laboratory for Biomedical Photonics, Huazhong University of Science and Technology, 430074, Wuhan, Hubei, China.
| |
Collapse
|
7
|
Rice TB, Yang B, White S. Effect of skin optical absorption on speckleplethysmographic (SPG) signals. BIOMEDICAL OPTICS EXPRESS 2020; 11:5352-5361. [PMID: 33014619 PMCID: PMC7510879 DOI: 10.1364/boe.403501] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2020] [Revised: 08/21/2020] [Accepted: 08/23/2020] [Indexed: 05/02/2023]
Abstract
Recent advances in optical technology have emerged for measuring blood flow in the extremities using speckleplethysmography (SPG), which may address needs in vascular medicine and other fields. SPG has demonstrated a highly linear response with flow rate, but the susceptibility to differences in skin tone is unclear. Two validation studies using skin-simulating phantoms and a simple clinical protocol were conducted to determine the impact of absorbing skin layers on SPG measurements. Benchtop results demonstrated that the coefficient of determination between known flow rate and SPG was highly linear (R2 = 0.990) and was unaffected by the addition of skin-phantom layers with variable absorption (R2 = 0.996-0.999). Additionally, no significant trend was found between the fit residuals of SPG and flow rate with increasing skin-phantom absorption (R2=0.025, p = 0.29). In clinical testing, no significant difference was found using both a 4-way ANOVA between demographic classifications (F = 0.89, p = 0.45), and a 2-way ANOVA test between lower- and higher-melanin subclassifications (F = 0.4, p = 0.52).
Collapse
|
8
|
Multipoint Tissue Circulation Monitoring with a Flexible Optical Probe. Sci Rep 2017; 7:9643. [PMID: 28852022 PMCID: PMC5575279 DOI: 10.1038/s41598-017-10115-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Accepted: 08/04/2017] [Indexed: 11/25/2022] Open
Abstract
Compromised circulation is a potential complication during the postoperative period following tissue transplantation. The use of a monitoring device allows physicians to detect compromised circulation immediately. Such monitoring devices need to be continuously usable, wearable, and area-detectable. However, existing devices fail to satisfy all of these requirements simultaneously. We developed a wearable, multipoint pulse wave-monitoring device. An array of reflective optical sensors implemented on a thin film substrate was used as a lightweight and flexible probe. As a model of tissue transplantation, an inguinal flap in a Wistar rat was dissected and freed from all subcutaneous tissue. By ligating the artery or vein, ischemia or congestion was induced in the tissue. In a human study, ischemia or congestion was induced in the palm by pressing the feeding artery or cutaneous vein, respectively. The amplitude of the pulse wave was evaluated using the power spectrum of Fourier transformed signals. Pulse wave amplitude significantly decreased under compromised circulation in both animal and human models. Moreover, we accomplished 1 week of continuous wireless monitoring in healthy subjects. These results demonstrated the potential utility of the developed device in postoperative blood-flow monitoring to improve the rescue rate of transplanted tissue.
Collapse
|
9
|
Lee J, Moon S, Lim J, Gwak MJ, Kim JG, Chung E, Lee JH. Imaging of the Finger Vein and Blood Flow for Anti-Spoofing Authentication Using a Laser and a MEMS Scanner. SENSORS 2017; 17:s17040925. [PMID: 28441728 PMCID: PMC5426921 DOI: 10.3390/s17040925] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 03/15/2017] [Accepted: 04/19/2017] [Indexed: 12/27/2022]
Abstract
A new authentication method employing a laser and a scanner is proposed to improve image contrast of the finger vein and to extract blood flow pattern for liveness detection. A micromirror reflects a laser beam and performs a uniform raster scan. Transmissive vein images were obtained, and compared with those of an LED. Blood flow patterns were also obtained based on speckle images in perfusion and occlusion. Curvature ratios of the finger vein and blood flow intensities were found to be nearly constant, regardless of the vein size, which validated the high repeatability of this scheme for identity authentication with anti-spoofing.
Collapse
Affiliation(s)
- Jaekwon Lee
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| | - Seunghwan Moon
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| | - Juhun Lim
- Department of Biomedical Science & Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| | - Min-Joo Gwak
- Fiber Optic Electronic R&D Center, Korea Optron Corporation (KOC), Gwangju 61007, Korea.
| | - Jae Gwan Kim
- Department of Biomedical Science & Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| | - Euiheon Chung
- Department of Biomedical Science & Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| | - Jong-Hyun Lee
- School of Mechanical Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
- Department of Biomedical Science & Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Korea.
| |
Collapse
|
10
|
Valdes CP, Varma HM, Kristoffersen AK, Dragojevic T, Culver JP, Durduran T. Speckle contrast optical spectroscopy, a non-invasive, diffuse optical method for measuring microvascular blood flow in tissue. BIOMEDICAL OPTICS EXPRESS 2014; 5:2769-84. [PMID: 25136500 PMCID: PMC4133004 DOI: 10.1364/boe.5.002769] [Citation(s) in RCA: 74] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 07/08/2014] [Accepted: 07/10/2014] [Indexed: 05/18/2023]
Abstract
We introduce a new, non-invasive, diffuse optical technique, speckle contrast optical spectroscopy (SCOS), for probing deep tissue blood flow using the statistical properties of laser speckle contrast and the photon diffusion model for a point source. The feasibility of the method is tested using liquid phantoms which demonstrate that SCOS is capable of measuring the dynamic properties of turbid media non-invasively. We further present an in vivo measurement in a human forearm muscle using SCOS in two modalities: one with the dependence of the speckle contrast on the source-detector separation and another on the exposure time. In doing so, we also introduce crucial corrections to the speckle contrast that account for the variance of the shot and sensor dark noises.
Collapse
Affiliation(s)
- Claudia P. Valdes
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels, Barcelona, Spain
- These authors contributed equally to this work
| | - Hari M. Varma
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels, Barcelona, Spain
- These authors contributed equally to this work
| | - Anna K. Kristoffersen
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels, Barcelona, Spain
| | - Tanja Dragojevic
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels, Barcelona, Spain
| | - Joseph P. Culver
- Department of Radiology, Washington University School of Medicine, St. Louis, MO 63130, USA
- Department of Physics, Washington University, St. Louis, MO 63130, USA
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels, Barcelona, Spain
| |
Collapse
|
11
|
Varma HM, Valdes CP, Kristoffersen AK, Culver JP, Durduran T. Speckle contrast optical tomography: A new method for deep tissue three-dimensional tomography of blood flow. BIOMEDICAL OPTICS EXPRESS 2014; 5:1275-89. [PMID: 24761306 PMCID: PMC3986001 DOI: 10.1364/boe.5.001275] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 03/10/2014] [Accepted: 03/11/2014] [Indexed: 05/18/2023]
Abstract
A novel tomographic method based on the laser speckle contrast, speckle contrast optical tomography (SCOT) is introduced that allows us to reconstruct three dimensional distribution of blood flow in deep tissues. This method is analogous to the diffuse optical tomography (DOT) but for deep tissue blood flow. We develop a reconstruction algorithm based on first Born approximation to generate three dimensional distribution of flow using the experimental data obtained from tissue simulating phantoms.
Collapse
Affiliation(s)
- Hari M. Varma
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels (Barcelona),
Spain
- These authors contributed equally to this work
| | - Claudia P. Valdes
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels (Barcelona),
Spain
- These authors contributed equally to this work
| | - Anna K. Kristoffersen
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels (Barcelona),
Spain
| | - Joseph P. Culver
- Department of Radiology, Washington University School of Medicine, St. Louis, MO 63110,
USA
- Department of Physics, Washington University, St. Louis, MO 63130,
USA
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, Av. Carl Friedrich Gauss, 3, 08860, Castelldefels (Barcelona),
Spain
| |
Collapse
|
12
|
Zhang H, Li P, Feng N, Qiu J, Li B, Luo W, Luo Q. Correcting the detrimental effects of nonuniform intensity distribution on fiber-transmitting laser speckle imaging of blood flow. OPTICS EXPRESS 2012; 20:508-517. [PMID: 22274372 DOI: 10.1364/oe.20.000508] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Laser speckle spatial contrast analysis (LSSCA) is superior to laser speckle temporal contrast analysis (LSTCA) in monitoring the fast change in blood flow due to its advantage of high temporal resolution. However, the application of LSSCA which is based on spatial statistics may be limited when there is nonuniform intensity distribution such as fiber-transmitting laser speckle imaging. In this study, we present a normalized laser speckle spatial contrast analysis (nLSSCA) to correct the detrimental effects of nonuniform intensity distribution on the spatial statistics. Through numerical simulation and phantom experiments, it is found that just ten frames of dynamic laser speckle images are sufficient for nLSSCA to achieve effective correction. Furthermore, nLSSCA has higher temporal resolution than LSTCA to respond the change in velocity. LSSCA, LSTCA and nLSSCA are all applied in the fiber-transmitting laser speckle imaging system to analyze the change of cortical blood flow (CBF) during cortical spreading depression (CSD) in rat cortex respectively, and the results suggest that nLSSCA can examine the change of CBF more accurately. For these advantages, nLSSCA could be a potential tool for fiber-transmitting/endoscopic laser speckle imaging.
Collapse
Affiliation(s)
- Hongyan Zhang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China
| | | | | | | | | | | | | |
Collapse
|
13
|
Free flap blood flow evaluated using two-dimensional laser speckle flowgraphy. Int J Otolaryngol 2011; 2011:297251. [PMID: 21716686 PMCID: PMC3118536 DOI: 10.1155/2011/297251] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2011] [Accepted: 03/02/2011] [Indexed: 12/03/2022] Open
Abstract
Objective. We investigated the efficiency of laser speckle flowgraphy for evaluating blood flow in free flaps used for plastic surgery.
Methods. We measured blood flow using a visual laser meter capable of providing two-dimensional color graphic representations of flow distribution for a given area using a dynamic laser speckle effect. Using laser speckle flowgraphy, we examined the blood flow of 20 free flaps applied following the excision of head and neck tumors.
Results. After anastomosis of the feeding and draining blood vessels and sewing the flap, musculocutaneous (MC) flaps showed significantly lower blood flow than jejunal or omental flaps (P < .05). The ratio of blood flow decrease from the edge to the center was significantly greater in MC flaps than in jejunal or omental flaps (P < .001).
Conclusion. Laser speckle flowgraphy is useful for the perioperative measurement of blood flow in free flaps used in plastic surgery. This method is a highly useful, practical, and reliable tool for assessing cutaneous blood flow and is expected to be applicable to several clinical fields.
Collapse
|