1
|
Ruan H, Song G, Fan Z, Hua L, Yang S, Kang J, Wang S, Wang W, Li H. Continuous atmospheric pressure interfaced ion trap mass spectrometry with thermal desorption for detection of nonvolatile drugs. Talanta 2025; 282:126975. [PMID: 39357409 DOI: 10.1016/j.talanta.2024.126975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Revised: 09/23/2024] [Accepted: 09/28/2024] [Indexed: 10/04/2024]
Abstract
The escalating need for prompt and highly sensitive on-site detection of trace-level drugs is fueling the advancement of miniature, high-performance mass spectrometers and analytical methodologies. In this study, a miniature continuous atmospheric pressure interfaced ion trap mass spectrometer integrated with thermal desorption acetone-assisted photoionization (TD-CAPI-ITMS) was developed for highly sensitive detection of nonvolatile drugs in saliva and blood. By strategically extending the sampling time of the TD-CAPI-ITMS to cover the entire desorption process, a remarkable two-order-of-magnitude enhancement in the signal intensity of individual drugs was observed. Moreover, the simultaneous detection of drug mixtures with widely varying boiling points and saturation vapor pressures was accomplished. Optimization of the parameters yielded a limit of detection (LOD) for ketamine and 5F-EMB-PICA of 1 pg/μL accompanied by a robust stability, as evidenced by a relative standard deviation (RSD) of 5.30 %. Combined with straightforward liquid-liquid extraction, the sensitivity of drugs in saliva as low as 10 pg/μL was achieved, which met the requirements of Chinese national standard GA1333-2017. Owing to its exceptional sensitivity, the matrix effect present in blood samples was significantly alleviated through dilution, allowing for accurate monitoring of antibiotic concentrations. The results underscore the substantial potential of the TD-CAPI-ITMS for lab-free applications in drug-related forensic analysis, therapeutic drug monitoring, and pharmacokinetic studies.
Collapse
Affiliation(s)
- Huiwen Ruan
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China
| | - Guiyun Song
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China; Northeastern University, College of Sciences, Research Center for Analytical Sciences, Department of Chemistry, Box 332, Shenyang, 110819, People's Republic of China
| | - Zhigang Fan
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China; University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing, 100049, People's Republic of China
| | - Lei Hua
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China
| | - Suosuo Yang
- Emergency Department, The 1st Affiliated Hospital of Dalian Medical University, Dalian, 116023, Liaoning, People's Republic of China
| | - Jian Kang
- Emergency Department, The 1st Affiliated Hospital of Dalian Medical University, Dalian, 116023, Liaoning, People's Republic of China
| | - Shuang Wang
- Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, 450001, People's Republic of China
| | - Weiguo Wang
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China; Jinkai Instrument (Dalian) Co., LTD, Dalian, 116023, Liaoning, People's Republic of China.
| | - Haiyang Li
- State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China; Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian, 116023, People's Republic of China.
| |
Collapse
|
2
|
Zhou D, Wu J, Wang Q, Liu Y, Wang S, Zhang W, Zhang Y, Ding H, Shao Y, Wang H, Shen Q. Miniature Mass Spectrometry for Point-of-Care Testing the GPIIb/IIIa Inhibitor Tirofiban during Perioperative Period of Percutaneous Coronary Intervention. ACS OMEGA 2024; 9:50326-50333. [PMID: 39741813 PMCID: PMC11683618 DOI: 10.1021/acsomega.4c06581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/16/2024] [Revised: 11/29/2024] [Accepted: 12/03/2024] [Indexed: 01/03/2025]
Abstract
Precise administration of tirofiban must be carefully considered to achieve the best treatment efficacy and maximize safety for patients. Herein, a paper spray ionization (PSI) linear ion trap (LIT) portable mass spectrometer (pMS) based point-of-care testing (POCT) technique was developed for on-site sampling, clinical testing, and immediate analysis of tirofiban blood drug concentrations. The results showed that tirofiban formed a significant and stable parent ion peak at m/z 441.3 by MS1 full scan in positive ion mode, which fragmented into product ions at m/z 395.4, m/z 321.3, m/z 276.3, and m/z 260.3 through collision-induced dissociation (CID) in MS/MS. To improve ion response, the parameters were optimized to the voltages of ionization 3600 V, ion isolation 1 (ISO1) 8 V, ion isolation 2 (ISO2) 2 V, and collision-induced dissociation (CID) 3 V. This method was validated, and the limit of detection (LOD) and limit of quantification (LOQ) were found to be 10.1 and 33.7 μg·L-1, respectively. For precision, it had the relative standard deviation (RSD) of interday precision of 4.8 to 6.7% and the RSD of intraday precision of 7.8 to 8.3%. The recovery of the method ranged from 87.5 to 93.4%. Although matrix effects in blood samples had some inhibitory effects on the target signal formation, the method compensated for part of the matrix effects by establishing a matrix-matched calibration curve, which exhibited good linearity with a R2 of 0.9987. Finally, the method was applied to the detection of tirofiban in clinically collected blood samples. Out of 12 samples, ten had tirofiban concentrations between 35.4 and 72.1 μg·L-1 while the remaining two were below the LOQ. The method needs further optimization and validation in the future to improve its sensitivity and stability.
Collapse
Affiliation(s)
- Dongchen Zhou
- Department
of Cardiology, First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310058, China
| | - Jiahui Wu
- Laboratory
of Food Nutrition and Clinical Research, Zhejiang Gongshang University, Hangzhou 310018, China
| | - Qingcheng Wang
- Laboratory
of Food Nutrition and Clinical Research, Zhejiang Gongshang University, Hangzhou 310018, China
| | - Yong Liu
- Key
Laboratory of Drug Monitoring and Control of Zhejiang Province, National Narcotics Laboratory Zhejiang Regional Center, Hangzhou 310053, China
| | - Shiqi Wang
- Department
of Cardiology, The First Affiliated Hospital
of Ningbo University, Ningbo 315000, China
| | - Weizong Zhang
- First
People’s Hospital of Linping District, Hangzhou 311100, China
| | - Yunfeng Zhang
- Institute
of Forensic Science, Ministry of Public
Security, Beijing 100038, China
| | - Huizhi Ding
- Department
of Cardiology, Sanmen People’s Hospital, Taizhou 317100, China
| | - Yunfei Shao
- Department
of Cardiology, Sanmen People’s Hospital, Taizhou 317100, China
| | - Haixing Wang
- Key
Laboratory of Drug Monitoring and Control of Zhejiang Province, National Narcotics Laboratory Zhejiang Regional Center, Hangzhou 310053, China
| | - Qing Shen
- Panvascular
Diseases Research Center, The Quzhou Affiliated
Hospital of Wenzhou Medical University, Quzhou People’s Hospital, Quzhou 324000, China
- Laboratory
of Food Nutrition and Clinical Research, Zhejiang Gongshang University, Hangzhou 310018, China
| |
Collapse
|
3
|
Ren J, Chen P, Zhang Y, He X, Li L, Li P. Direct Implementation of MS n Using Frequency Scanning Collision Induced Dissociation in a Digital Ion Trap Mass Spectrometer. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024. [PMID: 39711502 DOI: 10.1021/jasms.4c00395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2024]
Abstract
Tandem mass spectrometry (MSn) is one of the most effective methods to obtain the structures of organic molecules, enabling the observation of multigenerational ion fragments. Collision-induced dissociation (CID) is currently the most mature technique for mass spectrometry analysis. Ion trap mass spectrometry (ITMS) is favored for on-site detection field, due to its ability of MSn analysis with a single trap and its small size. However, conventional MSn analysis in ITMS requires repeated isolation and excitation processes multiple times, causing high complexity of the entire scanning process. Additionally, the fragment ion detection in ITMS is limited by low-mass cutoff (LMCO) and the weak fragmentation yield. In this study, a method named reverse scanning-collision induced dissociation (RS-CID) is proposed, which involves increasing RF and AC frequencies while maintaining RF voltage constant during the CID process. Twelve representative illegal drugs were analyzed adopting this method, enhancing the intensities of low-mass fragment ions compared to conventional dissociation method. Moreover, experimental results with ketamine and methamphetamine show that RS-CID effectively reduces the LMCO effect and slightly improves CID efficiency. It also enables direct acquisition of their multigeneration fragment ions spectra in a single sequence of ion injection, cooling, isolation, RS-CID, cooling, mass scanning and empty. The experiments to distinguish between the isomers ab-4en-pinaca and adb-3en-butinaca as well as the isomeric compounds 5f-cumyl-pegaclone and cumyl-pipetinaca were also successful by this method. In summary, RS-CID enables MSn analysis in a single sequence and improves the low-mass fragment ions intensity. It can simplify workflows, achieve faster analysis and provide more valuable mass spectral information.
Collapse
Affiliation(s)
- Jie Ren
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
| | - Pingping Chen
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
| | - Yunjing Zhang
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
| | - Xingli He
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
| | - Lingfeng Li
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
- Suzhou Weimu Intelligent System Co., Ltd., Suzhou 215163, China
| | - Peng Li
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China
- Suzhou Weimu Intelligent System Co., Ltd., Suzhou 215163, China
| |
Collapse
|
4
|
Sadeghi P, Alshawabkeh R, Rui A, Sun NX. A Comprehensive Review of Biomarker Sensors for a Breathalyzer Platform. SENSORS (BASEL, SWITZERLAND) 2024; 24:7263. [PMID: 39599040 PMCID: PMC11598263 DOI: 10.3390/s24227263] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2024] [Revised: 11/09/2024] [Accepted: 11/12/2024] [Indexed: 11/29/2024]
Abstract
Detecting volatile organic compounds (VOCs) is increasingly recognized as a pivotal tool in non-invasive disease diagnostics. VOCs are metabolic byproducts, mostly found in human breath, urine, feces, and sweat, whose profiles may shift significantly due to pathological conditions. This paper presents a thorough review of the latest advancements in sensor technologies for VOC detection, with a focus on their healthcare applications. It begins by introducing VOC detection principles, followed by a review of the rapidly evolving technologies in this area. Special emphasis is given to functionalized molecularly imprinted polymer-based biochemical sensors for detecting breath biomarkers, owing to their exceptional selectivity. The discussion examines SWaP-C considerations alongside the respective advantages and disadvantages of VOC sensing technologies. The paper also tackles the principal challenges facing the field and concludes by outlining the current status and proposing directions for future research.
Collapse
Affiliation(s)
- Pardis Sadeghi
- W.M. Keck Laboratory for Integrated Ferroics, Department of Electrical & Computer Engineering, Northeastern University, Boston, MA 02115, USA; (P.S.)
| | - Rania Alshawabkeh
- W.M. Keck Laboratory for Integrated Ferroics, Department of Electrical & Computer Engineering, Northeastern University, Boston, MA 02115, USA; (P.S.)
| | - Amie Rui
- W.M. Keck Laboratory for Integrated Ferroics, Department of Electrical & Computer Engineering, Northeastern University, Boston, MA 02115, USA; (P.S.)
| | - Nian Xiang Sun
- W.M. Keck Laboratory for Integrated Ferroics, Department of Electrical & Computer Engineering, Northeastern University, Boston, MA 02115, USA; (P.S.)
- Winchester Technologies LLC, Burlington, MA 01803, USA
| |
Collapse
|
5
|
Rodrillo KAM, Costa DM, Viana SFC, Shahbazi H, Augusti R, Ifa DR. Forensic application of sandpaper spray ionization mass spectrometry (SPS-MS): Direct analysis of solid pharmaceutical formulations and edible cannabis products. J Forensic Sci 2024; 69:2209-2221. [PMID: 39101585 DOI: 10.1111/1556-4029.15592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 06/25/2024] [Accepted: 06/27/2024] [Indexed: 08/06/2024]
Abstract
In this work, we employed a new ambient ionization mass spectrometry technique, sandpaper spray mass spectrometry (SPS-MS), as an efficient tool to analyze pills and tablets of pharmaceutical formulations. The following samples were analyzed: regulators of blood pressure, cholesterol, and diabetes, and drugs for the treatment of erectile dysfunction (ED). Additionally, a hard candy of Cannabis sativa containing Δ9-tetrahydrocannabinol (Δ9-THC) and its related isomer cannabidiol (CBD) was also evaluated. The surfaces of the samples, without any prior treatment, were sanded onto triangular-cut sandpaper, and full MS scans (and MS/MS) were acquired in both positive and negative ionization modes. SPS-MS (and MS/MS) allowed for prompt detection of the active pharmaceutical ingredients (APIs) in each formulation. Other components of the formulations, added as excipients, were also tentatively identified. The results described herein indicate that the SPS-MS technique can be applied to fast screening of pills and tablets being potentially used as an efficient tool to detect counterfeit pharmaceutical and illicit products, a current issue of increasing concern.
Collapse
Affiliation(s)
| | - Diego M Costa
- Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Sarah F C Viana
- Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Hasti Shahbazi
- Department of Chemistry, York University, Toronto, Ontario, Canada
| | - Rodinei Augusti
- Department of Chemistry, York University, Toronto, Ontario, Canada
- Department of Chemistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Demian R Ifa
- Department of Chemistry, York University, Toronto, Ontario, Canada
| |
Collapse
|
6
|
Mathias S, Amerio-Cox M, Jackson T, Douce D, McCullough B, Sage A, Luke P, Crean C, Sears P. Performance Comparison of Ambient Ionization Techniques Using a Single Quadrupole Mass Spectrometer for the Analysis of Amino Acids, Drugs, and Explosives. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:2480-2489. [PMID: 39221767 PMCID: PMC11457451 DOI: 10.1021/jasms.4c00277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/07/2024] [Accepted: 08/20/2024] [Indexed: 09/04/2024]
Abstract
The utilization of ambient ionization (AI) techniques for mass spectrometry (MS) has significantly grown due to their ability to facilitate rapid and direct sample analysis with minimal sample preparation. This study investigates the performance of various AI techniques, including atmospheric solids analysis probe (ASAP), thermal desorption corona discharge (TDCD), direct analysis in real time (DART), and paper spray coupled to a Waters QDa mass spectrometer. The focus is on evaluating the linearity, repeatability, and limit of detection (LOD) of these techniques across a range of analytes, including amino acids, drugs, and explosives. The results show that each AI technique exhibits distinct advantages and limitations. ASAP and DART cover high concentration ranges, which may make them suitable for semiquantitative analysis. TDCD demonstrates exceptional linearity and repeatability for most analytes, while paper spray offers surprising LODs despite its complex setup (between 80 and 400 pg for most analytes). The comparison with electrospray ionization (ESI) as a standard method shows that ambient ionization techniques can achieve competitive LODs for various compounds such as PETN (80 pg ESI vs 100 pg ASAP), TNT (9 pg ESI vs 4 pg ASAP), and RDX (4 pg ESI vs 10 pg ASAP). This study underscores the importance of selecting the appropriate ambient ionization technique based on the specific analytical requirements. This comprehensive evaluation contributes valuable insights into the selection and optimization of AI techniques for diverse analytical applications.
Collapse
Affiliation(s)
- Simone Mathias
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Marius Amerio-Cox
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Toni Jackson
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - David Douce
- Waters
Corporation, Stamford
Avenue, Wilmslow SK9 4AX, U.K.
| | | | - Ashley Sage
- Waters
Corporation, Stamford
Avenue, Wilmslow SK9 4AX, U.K.
| | - Peter Luke
- Mass
Spec Analytical, Future Space UWE North Gate, Bristol BS34 8RB, U.K.
| | - Carol Crean
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| | - Patrick Sears
- School
of Chemistry and Chemical Engineering, University
of Surrey, Guildford GU2 7XH, U.K.
| |
Collapse
|
7
|
Forbes TP, Robinson EL, Sisco E, Koss A. In-Line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives. Anal Chem 2024; 96:13352-13357. [PMID: 39103237 DOI: 10.1021/acs.analchem.4c02974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
Thermal desorption (TD) of wipe-based samples was coupled with an in-line dielectric barrier discharge ionization (DBDI) source and rugged compact time-of-flight mass spectrometer (MS) for the detection of explosives, propellants, and postblast debris. The chromatography-free TD-DBDI-MS platform enabled rapid and sensitive detection of organic nitramine, nitrate ester, and nitroaromatic explosives as well as black powder and black powder substitute propellants. Parametric investigations characterized the response to TD temperature and optimized DBDI voltage, aerodynamically assisted entrainment, and fragmentation through in-source collision induced dissociation (isCID). Excess nitrate generated by the DBDI source yielded predominantly nitrate-adduct formation. Subnanogram sensitivities were demonstrated for all explosives investigated, except for nitroglycerin, specifically due to its volatility. Further, most analytes/explosives exhibited tens of picograms sensitivities. The platform also demonstrated the detection of propellant and military explosives from postblast debris. The TD-DBDI-MS system performed well without the need for aerodynamically assisted entrainment (and the associated rough pump), which along with requiring no additional gases (i.e., N2 or He) or solvents, aid in potential field deployment. The ease of TD-DBDI attachment and removal added trace solid or liquid residue detection to the rugged mass spectrometer, designed primarily for the analysis of volatile organic and inorganic compounds.
Collapse
Affiliation(s)
- Thomas P Forbes
- Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Elizabeth L Robinson
- Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Edward Sisco
- Materials Measurement Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899, United States
| | - Abigail Koss
- TOFWERK USA, Boulder, Colorado 80301, United States
| |
Collapse
|
8
|
Kooij S, Chojnacka A, Bonn D, Corthals GL, van Rijn CJM. Electroless Ionization Mass Spectrometry Using a Compact Electrokinetic Ionization Source. Anal Chem 2024; 96:10978-10985. [PMID: 38917274 PMCID: PMC11238159 DOI: 10.1021/acs.analchem.4c01403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 06/10/2024] [Accepted: 06/11/2024] [Indexed: 06/27/2024]
Abstract
We introduce a new ionization technique for compact, portable mass spectrometers. It consists of a syringe with sample liquid capped by a self-ionizing spray nozzle containing a microfabricated nozzle chip. Interaction of the sample liquid with the nozzle wall results in electrical charging without the need for electronics. Elaborate cleaning procedures are redundant when disposable syringes and mass-fabricated spray nozzles are used. This self-named electroless spray ionization (ELI) technique shows comparable performance to conventional ionization techniques. In contrast to commonly used electrospray ionization, ELI exhibits excellent ionization efficiency for low-conductive solutions such as water or acetonitrile. Due to its compact size and the absence of high-voltage electronics, it can also be readily integrated in other ionization sources. Besides reviewing the main properties of ELI, we showcase the technique's potential for two on-site, ambient mass spectroscopy applications: perfume fingerprinting and fast screening of fungicides on citrus fruits.
Collapse
Affiliation(s)
- Stefan Kooij
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Aleksandra Chojnacka
- Van
’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Daniel Bonn
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Garry L. Corthals
- Van
’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| | - Cees J. M. van Rijn
- Van
der Waals-Zeeman Institute, University of
Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands
| |
Collapse
|
9
|
Frinculescu A, Mercer B, Shine T, Ramsey J, Couchman L, Douce D, Frascione N, Abbate V. Assessment of a Single Quadrupole Mass Spectrometer Combined with an Atmospheric Solids Analysis Probe for the On-Site Identification of Amnesty Bin Drugs. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1480-1489. [PMID: 38837752 PMCID: PMC11228975 DOI: 10.1021/jasms.4c00064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 05/16/2024] [Accepted: 05/20/2024] [Indexed: 06/07/2024]
Abstract
The surging number of people who abuse drugs has a great impact on healthcare and law enforcement systems. Amnesty bin drug analysis helps monitor the "street drug market" and tailor the harm reduction advice. Therefore, rapid and accurate drug analysis methods are crucial for on-site work. An analytical method for the rapid identification of five commonly detected drugs ((3,4-methylenedioxymethamphetamine (MDMA), cocaine, ketamine, 4-bromo-2,5-dimethoxyphenethylamine, and chloromethcathinone)) at various summer festivals in the U.K. was developed and validated employing a single quadrupole mass spectrometer combined with an atmospheric pressure solids analysis probe (ASAP-MS). The results were confirmed on a benchtop gas chromatography-mass spectrometry instrument and included all samples that challenged the conventional spectroscopic techniques routinely employed on-site. Although the selectivity/specificity step of the validation assessment of the MS system proved a challenge, it still produced 93% (N = 279) and 92.5% (N = 87) correct results when tested on- and off-site, respectively. A few "partly correct" results showed some discrepancies between the results, with the MS-only unit missing some low intensity active ingredients (N-ethylpentylone, MDMA) and cutting agents (caffeine, paracetamol, and benzocaine) or detecting some when not present. The incorrect results were mainly based on library coverage. The study proved that the ASAP-MS instrument can successfully complement the spectroscopic techniques used for qualitative drug analysis on- and off-site. Although the validation testing highlighted some areas for improvement concerning selectivity/specificity for structurally similar compounds, this method has the potential to be used in trend monitoring and harm reduction.
Collapse
Affiliation(s)
- Anca Frinculescu
- Department
of Analytical, Environmental and Forensic Sciences, King’s College London, 150 Stamford Street, London SE1 9NH, United
Kingdom
- TICTAC
Communications Limited, Room 1.159 Jenner Wing, St. George’s University of London, Cranmer Terrace, London SW17 0RE, United
Kingdom
| | - Benjamin Mercer
- Clinical
Pharmacology, William Harvey Research Institute, Queen Mary University of London, London EC1M 6BQ, United Kingdom
| | - Trevor Shine
- TICTAC
Communications Limited, Room 1.159 Jenner Wing, St. George’s University of London, Cranmer Terrace, London SW17 0RE, United
Kingdom
| | - John Ramsey
- TICTAC
Communications Limited, Room 1.159 Jenner Wing, St. George’s University of London, Cranmer Terrace, London SW17 0RE, United
Kingdom
| | - Lewis Couchman
- Department
of Analytical, Environmental and Forensic Sciences, King’s College London, 150 Stamford Street, London SE1 9NH, United
Kingdom
- Analytical
Services International, St. George’s
University of London, Cranmer Terrace, London SW17 0RE, United Kingdom
| | - David Douce
- Waters
Corporation, Stamford
Avenue, Wilmslow SK9 4AX, United Kingdom
| | - Nunzianda Frascione
- Department
of Analytical, Environmental and Forensic Sciences, King’s College London, 150 Stamford Street, London SE1 9NH, United
Kingdom
| | - Vincenzo Abbate
- Department
of Analytical, Environmental and Forensic Sciences, King’s College London, 150 Stamford Street, London SE1 9NH, United
Kingdom
| |
Collapse
|
10
|
Mörén L, Östin A, Larsson A, Forsberg J, Wiktelius D, Lindén P. Rapid screening of riot control agents using DART-TD-HRMS. Forensic Toxicol 2024; 42:152-162. [PMID: 38388823 PMCID: PMC11269514 DOI: 10.1007/s11419-024-00681-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Accepted: 01/07/2024] [Indexed: 02/24/2024]
Abstract
PURPOSE Riot Control Agents (RCAs) are chemicals used in law enforcement for non-lethal riot control and use in conflicts between states that violates the Chemical Weapons Convention. OPCW's Scientific Advisory Board has identified sixteen potential RCAs including capsaicinoids, CS, and CR. RCAs may be misused for criminal purposes, so methods for detecting such misuse are needed. This study therefore evaluates the feasibility of a rapid, high throughput screening method of RCAs on surfaces (particularly clothing surfaces) by Direct Analysis in Real Time with a thermal desorption unit coupled to high-resolution mass spectrometry (DART-TD-HRMS). METHODS A broadly applicable method for detecting potential RCAs was developed and tested on cotton fabric samples sprayed with self-defence sprays from an in-house reference stock. The feasibility of detecting RCAs by direct analysis of surface wipe samples placed in the DART source was also investigated. RESULTS The method detected all sixteen RCAs and contaminated clothing were successfully screened for active agents in a reference collection of self-defence sprays. A pilot study also showed that RCAs can be detected by holding a sample directly in front of the DART source. CONCLUSION DART-TD-HRMS enables rapid and simple screening of RCAs on fabric samples enabling a high sample throughput.
Collapse
Affiliation(s)
- Lina Mörén
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden
| | - Anders Östin
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden
| | - Andreas Larsson
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden
| | - Julia Forsberg
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden
| | - Daniel Wiktelius
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden
| | - Pernilla Lindén
- FOI, Swedish Defence Research Agency, CBRN Defence & Security, SE 901 82, Umeå, Sweden.
| |
Collapse
|
11
|
Liu X, Huang Q, Deng J, Liu X, Hu B. Portable Mass Spectrometry for On-site Detection of Hazardous Volatile Organic Compounds via Robotic Extractive Sampling. Anal Chem 2024; 96:9325-9331. [PMID: 38758929 DOI: 10.1021/acs.analchem.4c01555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/19/2024]
Abstract
Various hazardous volatile organic compounds (VOCs) are frequently released into environments during accidental events that cause many hazards to ecosystems and humans. Therefore, rapid, sensitive, and on-site detection of hazardous VOCs is crucial to understand their compositions, characteristics, and distributions in complex environments. However, manual handling of hazardous VOCs remains a challenging task, because of the inaccessible environments and health risk. In this work, we designed a quadruped robotic sampler to reach different complex environments for capturing trace hazardous VOCs using a needle trap device (NTD) by remote manipulation. The captured samples were rapidly identified by portable mass spectrometry (MS) within minutes. Rapid detection of various hazardous VOCs including toxicants, chemical warfare agents, and burning materials from different environments was successfully achieved using this robot-MS system. On-site detection of 83 typical hazardous VOCs was examined. Acceptable analytical performances including low detection limits (at subng/mL level), good reproducibility (relative standard deviation (RSD) < 20%, n = 6), excellent quantitative ability (R2 > 0.99), and detection speed (within minutes) were also obtained. Our results show that the robot-MS system has excellent performance including safety, controllability, applicability, and robustness under dangerous chemical conditions.
Collapse
Affiliation(s)
- Ximeng Liu
- College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Qiaoyun Huang
- College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Jiewei Deng
- Smart Medical Innovation Technology Center, School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou 510006, China
| | - Xuan Liu
- College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- College of Environment and Climate, Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, and Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| |
Collapse
|
12
|
Lemmink IB, Straub LV, Bovee TFH, Mulder PPJ, Zuilhof H, Salentijn GI, Righetti L. Recent advances and challenges in the analysis of natural toxins. ADVANCES IN FOOD AND NUTRITION RESEARCH 2024; 110:67-144. [PMID: 38906592 DOI: 10.1016/bs.afnr.2024.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/23/2024]
Abstract
Natural toxins (NTs) are poisonous secondary metabolites produced by living organisms developed to ward off predators. Especially low molecular weight NTs (MW<∼1 kDa), such as mycotoxins, phycotoxins, and plant toxins, are considered an important and growing food safety concern. Therefore, accurate risk assessment of food and feed for the presence of NTs is crucial. Currently, the analysis of NTs is predominantly performed with targeted high pressure liquid chromatography tandem mass spectrometry (HPLC-MS/MS) methods. Although these methods are highly sensitive and accurate, they are relatively expensive and time-consuming, while unknown or unexpected NTs will be missed. To overcome this, novel on-site screening methods and non-targeted HPLC high resolution mass spectrometry (HRMS) methods have been developed. On-site screening methods can give non-specialists the possibility for broad "scanning" of potential geographical regions of interest, while also providing sensitive and specific analysis at the point-of-need. Non-targeted chromatography-HRMS methods can detect unexpected as well as unknown NTs and their metabolites in a lab-based approach. The aim of this chapter is to provide an insight in the recent advances, challenges, and perspectives in the field of NTs analysis both from the on-site and the laboratory perspective.
Collapse
Affiliation(s)
- Ids B Lemmink
- Laboratory of Organic Chemistry, Wageningen University & Research, Wageningen, The Netherlands; Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands
| | - Leonie V Straub
- Laboratory of Organic Chemistry, Wageningen University & Research, Wageningen, The Netherlands; Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands
| | - Toine F H Bovee
- Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands
| | - Patrick P J Mulder
- Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands
| | - Han Zuilhof
- Laboratory of Organic Chemistry, Wageningen University & Research, Wageningen, The Netherlands; School of Pharmaceutical Sciences and Technology, Tianjin University, Tianjin, P.R. China
| | - Gert Ij Salentijn
- Laboratory of Organic Chemistry, Wageningen University & Research, Wageningen, The Netherlands; Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands.
| | - Laura Righetti
- Laboratory of Organic Chemistry, Wageningen University & Research, Wageningen, The Netherlands; Wageningen Food Safety Research, Wageningen University & Research, Wageningen, The Netherlands.
| |
Collapse
|
13
|
Cheng Y, Liu Y, Wu Z, Shen C, Li S, Wang H, Chen C. Concept and simulation of a novel dual-layer linear ion trap mass analyzer for micro-electromechanical systems mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2024; 30:150-160. [PMID: 38706254 DOI: 10.1177/14690667241251792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2024]
Abstract
This paper proposed a dual-layer linear ion trap mass analyzer (dLIT) based on micro-electromechanical systems (MEMS) technology and stacked-layer structure for the development of MEMS mass spectrometry. Its basic performance and potential capabilities were explored by ion trajectory simulations. The theoretical formulas were modified by implementing multipole expansion. The simulation results were confirmed to be highly consistent with theoretical calculations in multiple aspects, including stability diagram, secular frequencies, and mass linearity, with only a deviation of 1-2%. In the boundary ejection mode, close to 100% ejection was achieved in a single dimension by applying extra quadrupole DC voltage. Preliminary simulation results showed that dLIT can achieve a peak width of ∼2 mass units (full width at half maximum, FWHM) for m/z 60 ions even at pressures as high as 50 Pa. Furthermore, the application of AC frequency scanning mode in dLIT was also evaluated, and preliminary simulation results yield a peak width of 0.3-0.4 mass units (FWHM). The dLIT offered several advantages, including high-precision fabrication at the sub-millimeter scale, excellent high-pressure performance, and a clear physical model. It preliminarily proved to be an ideal mass analyzer for MEMS mass spectrometry.
Collapse
Affiliation(s)
- Yupeng Cheng
- University of Science and Technology of China, Hefei, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Youjiang Liu
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Zhangxu Wu
- University of Science and Technology of China, Hefei, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Chen Shen
- University of Science and Technology of China, Hefei, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Shan Li
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Han Wang
- University of Science and Technology of China, Hefei, China
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Chilai Chen
- Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| |
Collapse
|
14
|
Bondzie EH, Adehinmoye A, Molnar BT, Fedick PW, Mulligan CC. Application of a Modified 3D-PCSI-MS Ion Source to On-Site, Trace Evidence Processing via Integrated Vacuum Collection. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:82-89. [PMID: 38064434 DOI: 10.1021/jasms.3c00317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
Trace evidence, including hair, fibers, soil/dust, and gunshot residue (GSR), can be recovered from a crime scene to help identify or associate a suspect with illegal activities via physical, chemical, and biological testing. Vacuum collection is one technique that is employed in recovering such trace evidence but is often done so in a targeted manner, leaving other complementary, chemical-specific information unexamined. Here, we describe a modified 3D-printed cone spray ionization (3D-PCSI) source with integrated vacuum collection for on-site, forensic evidence screening, allowing the processing of targeted physical traces and nontargeted chemical species alike. The reported form factor allows sample collection, onboard extraction, filtration, and spray-based ionization in a singular vessel with minimal handling of evidence by the operator. Utilizing authentic forensic evidence types and portable MS instrumentation, this new method was characterized through systematic studies that replicate CSI applications. Reliability in the form of false positive/negative response rates was determined from a modest, user-blinded data set, and other attributes, such as collection efficacy and detection limit, were examined.
Collapse
Affiliation(s)
- Ebenezer H Bondzie
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| | - Adewale Adehinmoye
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| | - Brian T Molnar
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, United States
| | - Patrick W Fedick
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, United States
| | - Christopher C Mulligan
- Department of Chemistry, Illinois State University, Normal, Illinois 61704, United States
| |
Collapse
|
15
|
Zacometti C, Tata A, Stella R, Leone S, Pallante I, Merenda M, Catania S, Pozzato N, Piro R. DART-HRMS allows the detection of toxic alkaloids in animal autopsy specimens and guides the selection of confirmatory methods in accidental plant poisoning. Anal Chim Acta 2023; 1264:341309. [PMID: 37230724 DOI: 10.1016/j.aca.2023.341309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 04/26/2023] [Accepted: 04/30/2023] [Indexed: 05/27/2023]
Abstract
BACKGROUND In cases of suspected animal poisonings or intoxications, there is the need for high-throughput, rapid and accurate analytical tools capable of giving rapid answers and, thus, speeding up the early stages of investigations. Conventional analyses are very precise, but do not meet the need for rapid answers capable of orienting the decisions and the choice of appropriate countermeasures. In this context, the use of ambient mass spectrometry (AMS) screening methods in toxicology laboratories could satisfy the requests of forensic toxicology veterinarians in a timely manner. RESULTS As a proof of principle, direct analysis in real time high resolution mass spectrometry (DART-HRMS) was applied to a veterinary forensic case in which 12 of a group of 27 sheep and goats died with an acute neurological onset. Because of evidence in the rumen contents, the veterinarians hypothesized an accidental intoxication after ingestion of vegetable materials. The DART-HRMS results showed abundant signals of the alkaloids calycanthine, folicanthidine and calycanthidine, both in the rumen content and at the liver level. The DART-HRMS phytochemical fingerprinting of detached Chimonanthus praecox seeds was also compared with those acquired from the autopsy specimens. Liver, rumen content and seed extracts were then subjected to LC-HRMS/MS analysis to gather additional insights and confirm the putative assignment of calycanthine anticipated by DART-HRMS. HPLC-HRMS/MS confirmed the presence of calycanthine in both rumen contents and liver specimens and allowed its quantification, ranging from 21.3 to 46.9 mg kg-1 in the latter. This is the first report detailing the quantification of calycanthine in liver after a deadly intoxication event. SIGNIFICANCE AND NOVELTY Our study illustrates the potential of DART-HRMS to offer a rapid and complementary alternative to guide the selection of confirmatory chromatography-MSn strategies in the analysis of autopsy specimens from animals with suspected alkaloid intoxication. This method offers the consequent saving of time and resources over those needed for other methods.
Collapse
Affiliation(s)
- Carmela Zacometti
- Laboratorio di Chimica Sperimentale, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy
| | - Alessandra Tata
- Laboratorio di Chimica Sperimentale, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy.
| | - Roberto Stella
- Laboratorio Farmaci Veterinari e Ricerca, Istituto Zooprofilattico Sperimentale delle Venezie, Viale dell'Università, 10, 35020, Legnaro, PD, Italy
| | - Stefania Leone
- Laboratorio di Diagnostica Clinica e Sierologia di Piano, Istituto Zooprofilattico Sperimentale delle Venezie, via Bovolino, 1/C, 37060, Buttapietra, VR, Italy; Laboratorio di Medicina Forense Veterinaria, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy
| | - Ivana Pallante
- Laboratorio di Medicina Forense Veterinaria, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy
| | - Marianna Merenda
- Laboratorio di Diagnostica Clinica e Sierologia di Piano, Istituto Zooprofilattico Sperimentale delle Venezie, via Bovolino, 1/C, 37060, Buttapietra, VR, Italy
| | - Salvatore Catania
- Laboratorio di Diagnostica Clinica e Sierologia di Piano, Istituto Zooprofilattico Sperimentale delle Venezie, via Bovolino, 1/C, 37060, Buttapietra, VR, Italy
| | - Nicola Pozzato
- Laboratorio di Medicina Forense Veterinaria, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy
| | - Roberto Piro
- Laboratorio di Chimica Sperimentale, Istituto Zooprofilattico Sperimentale delle Venezie, Viale Fiume, 78, 36100, Vicenza, VI, Italy
| |
Collapse
|
16
|
Jackson GP, Barkett MA. Forensic Mass Spectrometry: Scientific and Legal Precedents. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37276607 DOI: 10.1021/jasms.3c00124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Mass spectrometry has made profound contributions to the criminal justice system by providing an instrumental method of analysis that delivers exquisite analytical figures of merit for a wide variety of samples and analytes. Applications include the characterization of trace metal impurities in hair and glass to the identification of drugs, explosives, polymers, and ignitable liquids. This review describes major historical developments and, where possible, relates the developed capabilities to casework and legal precedents. This review also provides insight into how historical applications have evolved into, and out of, modern consensus standards. Unlike many pattern-based techniques and physical-matching methods, mass spectrometry has strong scientific foundations and a long history of successful applications that have made it one of the most reliable and respected sources of scientific evidence in criminal and civil cases. That said, in several appellate decisions in which mass spectrometric evidence was challenged but admitted, decisions sometimes still went against the mass spectrometric data anyway, which goes to show that mass spectrometric evidence is always just one piece of the larger legal puzzle.
Collapse
Affiliation(s)
- Glen P Jackson
- Department of Forensic and Investigative Science, West Virginia University, Morgantown, West Virginia 26506-6121, United States
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Mark A Barkett
- Dover Chemical Company, Dover, Ohio 44622, United States
| |
Collapse
|
17
|
Nazdrajić E, Murtada K, Rickert DA, Pawliszyn J. Coupling of Solid-Phase Microextraction Directly to Mass Spectrometry via an Improved Microfluidic Open Interface to Facilitate High-Throughput Determinations. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37004172 DOI: 10.1021/jasms.2c00380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Mass spectrometry analysis can be performed by introducing samples directly to mass spectrometry, allowing the increase of the analysis throughput; however, some disadvantages of direct-to-mass spectrometry analysis include susceptibility to matrix effects and risk of instrument contamination from inadequate sample preparation. Solid-phase microextraction is one of the most suitable sample preparation methods for direct-to-mass spectrometry analysis, as it offers matrix-compatible coatings which ensure analyte enrichment with minimal or no interference from matrix. One of the ways solid-phase microextraction can be coupled directly to mass spectrometry is via a microfluidic open interface. This manuscript reports improvements made to the initial microfluidic open interface design, where the system components have been simplified to mostly commercially available materials. In addition, the analysis of samples has been automated by implementing software that fully controls the analysis workflow, where the washing procedure is optimized to completely reduce the carryover. Herein, the extraction and desorption time profiles from thin and thick SPME devices was studied where the overall workflow consisted of high-throughput sample preparation of 1.3 min per 96 samples and <1 min per sample instrumental analysis.
Collapse
Affiliation(s)
- Emir Nazdrajić
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Khaled Murtada
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Daniel A Rickert
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Janusz Pawliszyn
- Department of Chemistry, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
18
|
Pandey S, Hu Y, Anderson PL, Kiser JJ, Cooks RG. Miniature mass spectrometer-based point-of-care assay for measuring phosphatidylethanol in blood. Analyst 2023; 148:1430-1436. [PMID: 36892479 PMCID: PMC10061498 DOI: 10.1039/d3an00098b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
We demonstrate proof-of-concept for point-of-care assessment of long-term alcohol consumption by measuring phosphatidylethanol in blood/dried blood spots with nano-electrospray ionization and MS/MS using a miniature mass spectrometer. 'Abstinence', 'moderate', and 'chronic' consumption could be distinguished rapidly for both sample types, and quantitative performance was obtained with blood (LoQ-100 ng mL-1).
Collapse
Affiliation(s)
- Sangeeta Pandey
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| | - Yanyang Hu
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| | - Peter L Anderson
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Aurora, CO 80045, USA.
| | - Jennifer J Kiser
- Skaggs School of Pharmacy and Pharmaceutical Sciences, University of Colorado Denver, Aurora, CO 80045, USA.
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA.
| |
Collapse
|
19
|
Epping R, Koch M. On-Site Detection of Volatile Organic Compounds (VOCs). Molecules 2023; 28:1598. [PMID: 36838585 PMCID: PMC9966347 DOI: 10.3390/molecules28041598] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/03/2023] [Accepted: 02/05/2023] [Indexed: 02/11/2023] Open
Abstract
Volatile organic compounds (VOCs) are of interest in many different fields. Among them are food and fragrance analysis, environmental and atmospheric research, industrial applications, security or medical and life science. In the past, the characterization of these compounds was mostly performed via sample collection and off-site analysis with gas chromatography coupled to mass spectrometry (GC-MS) as the gold standard. While powerful, this method also has several drawbacks such as being slow, expensive, and demanding on the user. For decades, intense research has been dedicated to find methods for fast VOC analysis on-site with time and spatial resolution. We present the working principles of the most important, utilized, and researched technologies for this purpose and highlight important publications from the last five years. In this overview, non-selective gas sensors, electronic noses, spectroscopic methods, miniaturized gas chromatography, ion mobility spectrometry and direct injection mass spectrometry are covered. The advantages and limitations of the different methods are compared. Finally, we give our outlook into the future progression of this field of research.
Collapse
Affiliation(s)
- Ruben Epping
- Division of Organic Trace and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, 12489 Berlin, Germany
| | - Matthias Koch
- Division of Organic Trace and Food Analysis, Bundesanstalt für Materialforschung und -Prüfung, 12489 Berlin, Germany
| |
Collapse
|
20
|
Klapec DJ, Czarnopys G, Pannuto J. Interpol review of the analysis and detection of explosives and explosives residues. Forensic Sci Int Synerg 2023; 6:100298. [PMID: 36685733 PMCID: PMC9845958 DOI: 10.1016/j.fsisyn.2022.100298] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Affiliation(s)
- Douglas J. Klapec
- Arson and Explosives Section I, United States Department of Justice, Bureau of Alcohol, Tobacco, Firearms and Explosives, Forensic Science Laboratory, 6000 Ammendale Road, Ammendale, MD, 20705, USA
| | - Greg Czarnopys
- Forensic Services, United States Department of Justice, Bureau of Alcohol, Tobacco, Firearms and Explosives, Forensic Science Laboratory, 6000 Ammendale Road, Ammendale, MD, 20705, USA
| | - Julie Pannuto
- United States Department of Justice, Bureau of Alcohol, Tobacco, Firearms and Explosives, Forensic Science Laboratory, 6000 Ammendale Road, Ammendale, MD, 20705, USA
| |
Collapse
|
21
|
Affiliation(s)
- David Love
- United States Drug Enforcement Administration, Special Testing and Research Laboratory, USA
| | - Nicole S. Jones
- RTI International, Applied Justice Research Division, Center for Forensic Sciences, 3040 E. Cornwallis Road, Research Triangle Park, NC, 22709-2194, USA
- 70113 Street, N.W., Suite 750, Washington, DC, 20005-3967, USA
| |
Collapse
|
22
|
Ruan H, Xu C, Wang W, Li H. Hexapole-Assisted Continuous Atmospheric Pressure Interface for a High-Pressure Photoionization Miniature Ion Trap Mass Spectrometer. Anal Chem 2022; 94:17287-17294. [PMID: 36451554 DOI: 10.1021/acs.analchem.2c04274] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
Miniature mass spectrometers are powerful tools for on-site chemical analysis in the fields of homeland security, personal healthcare, and environmental monitoring. This study presents a novel hexapole-assisted continuous atmospheric pressure interface for a high-pressure photoionization miniature ion trap mass spectrometer (HA-HPPI-IT). Efficient ion transmission was achieved by combining radial focusing by an RF electric field and axial driving by gas flow, which was demonstrated by SIMION simulation and experimental verification. The pressure in the ionization-transmission chamber and the inner diameter of the skimmer were optimized, which helped in determining the number density of product ions and affected the ion transmission in the hexapole, respectively. After systematic optimizations, about 16-fold increase in signal intensity was achieved as the RF amplitude was varied from 140 to 400 Vpp, and a limit of detection of 1 ppbv was obtained. In addition, the HA-HPPI-IT exhibited high stability and the relative standard deviation was as low as 5.47%. Finally, the apparatus was applied for discovering the simulated spot for illicit drug synthesis by detecting toluene and propiophenone released to air and monitoring the evolutions of perchloroethylene residues from dry-cleaned clothes.
Collapse
Affiliation(s)
- Huiwen Ruan
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Chuting Xu
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,University of Chinese Academy of Sciences, 19 Yuquan Road, Beijing100049, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Weiguo Wang
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| | - Haiyang Li
- Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Key Laboratory for Online Analytical Instrumentation, 457 Zhongshan Road, Dalian116023, People's Republic of China.,Dalian Engineering Research Center of Breath Diagnostic Technology, Dalian116023, People's Republic of China
| |
Collapse
|
23
|
Wang J, Pursell ME, DeVor A, Awoyemi O, Valentine SJ, Li P. Portable mass spectrometry system: instrumentation, applications, and path to 'omics analysis. Proteomics 2022; 22:e2200112. [PMID: 36349734 PMCID: PMC10278091 DOI: 10.1002/pmic.202200112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/27/2022] [Accepted: 10/28/2022] [Indexed: 11/11/2022]
Abstract
Mass spectrometry (MS) is an information rich analytical technique and plays a key role in various 'omics studies. Standard mass spectrometers are bulky and operate at high vacuum, which hinder their adoption by the broader community and utility in field applications. Developing portable mass spectrometers can significantly expand the application scope and user groups of MS analysis. This review discusses the basics and recent advancements in the development of key components of portable mass spectrometers including ionization source, mass analyzer, detector, and vacuum system. Further, major areas where portable mass spectrometers are applied are also discussed. Finally, a perspective on the further development of portable mass spectrometers including the potential benefits for 'omics analysis is provided.
Collapse
Affiliation(s)
- Jing Wang
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Madison E. Pursell
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Amanda DeVor
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Olanrewaju Awoyemi
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Stephen J. Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| | - Peng Li
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, USA
| |
Collapse
|
24
|
Li L, Zhang T, Wang D, Zhang Y, He X, Wang X, Li P. Portable Digital Linear Ion Trap Mass Spectrometer Based on Separate-Region Corona Discharge Ionization Source for On-Site Rapid Detection of Illegal Drugs. Molecules 2022; 27:molecules27113506. [PMID: 35684444 PMCID: PMC9182377 DOI: 10.3390/molecules27113506] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 05/27/2022] [Accepted: 05/27/2022] [Indexed: 12/04/2022] Open
Abstract
As narcotic control has become worse in the past decade and the death toll of drug abuse hits a record high, there is an increasing demand for on-site rapid detection of illegal drugs. This work developed a portable digital linear ion trap mass spectrometer based on separate-region corona discharge ionization source to meet this need. A separate design of discharge and reaction regions was adopted with filter air as both carrier gas for the analyte and protection of the corona discharge needle. The linear ion trap was driven by a digital waveform with a low voltage (±100 V) to cover a mass range of 50–500 Da with a unit resolution at a scan rate of 10,000 Da/s. Eighteen representative drugs were analyzed, demonstrating excellent qualitative analysis capability. Tandem mass spectrometry (MS/MS) was also performed by ion isolation and collision-induced dissociation (CID) with air as a buffer gas. With cocaine as an example, over two orders of magnitude dynamic range and 10 pg of detection limit were achieved. A single analysis time of less than 10 s was obtained by comparing the information of characteristic ions and product ions with the built-in database. Analysis of a real-world sample further validated the feasibility of the instrument, with the results benchmarked by GC-MS. The developed system has powerful analytical capability without using consumables including solvent and inert gas, meeting the requirements of on-site rapid detection applications.
Collapse
Affiliation(s)
- Lingfeng Li
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
| | - Tianyi Zhang
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
| | - Deting Wang
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
| | - Yunjing Zhang
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
| | - Xingli He
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
| | - Xiaozhi Wang
- College of Information Science & Electronic Engineering, Zhejiang University, Hangzhou 310027, China;
| | - Peng Li
- School of Electronic and Information Engineering, Soochow University, Suzhou 215006, China; (L.L.); (T.Z.); (D.W.); (Y.Z.); (X.H.)
- Correspondence: ; Tel.: +86-136-562-498-81
| |
Collapse
|
25
|
Mass Spectrometry and Mass Spectrometry Imaging-based Thyroid Cancer Analysis. JOURNAL OF ANALYSIS AND TESTING 2022. [DOI: 10.1007/s41664-022-00218-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
26
|
Forbes TP, Lawrence J, Hao C, Gillen G. Open port sampling interface mass spectrometry of wipe-based explosives, oxidizers, and narcotics for trace contraband detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:3453-3460. [PMID: 34291248 PMCID: PMC9972214 DOI: 10.1039/d1ay01038g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Rapid screening for chemical traces of explosives and narcotics is widely used to support homeland security and law enforcement. These target compounds span a range of physicochemical properties from organic to inorganic, with preferential ionization pathways in both negative and positive mode operation. Nonvolatile inorganic oxidizers present in homemade fuel-oxidizer mixtures, pyrotechnics, and propellants create a unique challenge to traditional thermal desorption-based technologies. Developments in solid-liquid extraction techniques, specifically, open port sampling interface mass spectrometry (OPSI-MS) provide compelling capabilities to address these hurdles. In this proof of concept study, we investigated the trace detection of wipe-based (i.e., common swipe sampling collection method) explosives, oxidizers, and narcotics using an OPSI source and compact single quadrupole mass analyzer. The liquid dissolution and extraction capabilities of OPSI enabled detection of both traditional military-grade explosives and homemade explosive oxidizers. OPSI-MS sensitivities to a series of seven target compounds from polytetrafluoroethylene (PTFE) coated fiberglass sampling wipes were on the order of several nanograms to sub-nanogram levels. Comparisons with direct solution-based sample analysis enabled quantification of wipe-based sample extraction effects. The system demonstrated quick temporal responses, polarity switching capabilities, and rapid signal decay with minimal carryover, all critical to high throughput screening applications. Coupling traditional swipe sampling with OPSI-MS offers a promising tool for contraband screening applications.
Collapse
Affiliation(s)
- Thomas P Forbes
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
| | - Jeffrey Lawrence
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
| | | | - Greg Gillen
- National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
| |
Collapse
|
27
|
Roadside Drug Testing Approaches. Molecules 2021; 26:molecules26113291. [PMID: 34072538 PMCID: PMC8199318 DOI: 10.3390/molecules26113291] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 05/21/2021] [Accepted: 05/26/2021] [Indexed: 01/01/2023] Open
Abstract
The purpose of this review is to present an overview of roadside drug testing, driving enforcement, and drunk/drug driving detection around the world. Drunk and drug driving is a severe problem, not only in the UAE, but also around the world. This has important implications for road safety as drunk or drug driving may increase the chances of a driver’s involvement in a road crash when compared to a drug-free driver. Recently, due to increases in drug-impaired drivers’ crash involvement, many mobile roadside drug testing devices have been introduced to the market. These devices use oral fluid, urine or blood matrices. These are on-the-spot tests, which are easy to use and are applied by law enforcement agencies and the public. Law enforcement agencies most commonly use oral fluid to detect the presence of illicit drugs in drivers. This review discusses all the available devices in the market used by the authorities. It also describes the type of drugs widely abused by drivers along with behavioral testing methods. The different types of matrices used for roadside drug testing are also evaluated. Sample collection, storage, and pre-treatment methods are discussed, followed by the confirmatory analysis of positive samples. This article will significantly help law enforcement agencies compare and evaluate all the reliable roadside testing devices and new emerging confirmatory devices available to them in the market. This will help them make an informed decision on which device to adapt to their individual needs.
Collapse
|
28
|
Brown HM, McDaniel TJ, Doppalapudi KR, Mulligan CC, Fedick PW. Rapid, in situ detection of chemical warfare agent simulants and hydrolysis products in bulk soils by low-cost 3D-printed cone spray ionization mass spectrometry. Analyst 2021; 146:3127-3136. [PMID: 33999086 DOI: 10.1039/d1an00255d] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Chemical warfare agents (CWAs) are toxic chemicals that have been used as disabling or lethal weapons in war, terrorist attacks, and assasinations. The Chemical Weapons Convention (CWC) has prohibited the use, development, production, and stockpiling of CWAs since its initiation in 1997, however, the threat of deployment still looms. Detection of trace CWAs post-deployment or post-remediation, in bulk matrices such as soil, often requires lengthy sample preparation steps or extensive chromatographic separation times. 3D-printed cone spray ionization (3D-PCSI), an ambient ionization mass spectrometric (MS) technique, provides a rapid, simple, and low-cost method for trace CWA analysis in soil matrices for both in-laboratory and in-field detection. Described here is the utilization of conductive 3D-printed cones to perform both rapid sampling and ionization for CWA simulants and hydrolysis products in eight solid matrices. The analysis of trace quantities of CWA simulants and hydrolysis products by 3D-PCSI-MS coupled to both a commercial benchtop system and a field-portable MS system is detailed. Empirical limits of detection (LOD) for CWA simulants on the benchtop MS ranged from 100 ppt to 750 ppb and were highly dependant on solid matrix composition, with the portable system yielding similar spectral data from alike matrices, albeit with lower sensitivity.
Collapse
Affiliation(s)
- Hilary M Brown
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, USA.
| | - Trevor J McDaniel
- Department of Chemistry, Illinois State University, Normal, Illinois 61790, USA.
| | - Karan R Doppalapudi
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, USA.
| | | | - Patrick W Fedick
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, USA.
| |
Collapse
|
29
|
Forbes TP, Gillen G. DART-MS Spectral Similarity of Infrared Thermally Desorbed Solid Particulate and Solution Cast Propellant Samples. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1033-1040. [PMID: 33661626 PMCID: PMC9703350 DOI: 10.1021/jasms.1c00015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Security and forensic applications employ test and reference materials to develop, calibrate, and validate analytical instrumentation such as mass spectrometry for the trace detection and chemical analysis of target analytes. An emerging class of target analytes includes homemade fuel oxidizer explosives based on pyrotechnics, propellants, and powder mixtures. Test materials for these compounds must appropriately and accurately embody the physical and chemical nature of the threat. Precision liquid deposition methods have long been employed for creation of trace level test materials. Mass spectral similarity and chemical signature differences between solid particulate and solution cast (i.e., liquid deposited) propellant samples were investigated by infrared thermal desorption direct analysis in real time mass spectrometry (IRTD-DART-MS). Differences in the mass spectra and ion distributions of solid and liquid deposited black powders and black powder substitutes were observed. These differences were attributed to chemical processes (e.g., degradation) and physical differences in the crystal formation, spatial distribution, morphology, and size. The production and deposition of test and reference materials remain critical to developing new technologies and detecting evolving threats.
Collapse
|
30
|
Meisenbichler C, Kluibenschedl F, Müller T. A 3-in-1 Hand-Held Ambient Mass Spectrometry Interface for Identification and 2D Localization of Chemicals on Surfaces. Anal Chem 2020; 92:14314-14318. [PMID: 33063994 PMCID: PMC7643069 DOI: 10.1021/acs.analchem.0c02615] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
![]()
Desorption electrospray ionization
(DESI), easy ambient sonic-spray
ionization (EASI) and low-temperature plasma (LTP) ionization are
powerful ambient ionization techniques for mass spectrometry. However,
every single method has its limitation in terms of polarity and molecular
weight of analyte molecules. After the miniaturization of every possible
component of the different ion sources, we finally were able to embed
two emitters and an ion transfer tubing into a small, hand-held device.
The pen-like interface is connected to the mass spectrometer and a
separate control unit via a bundle of flexible tubing and cables.
The novel device allows the user to ionize an extended range of chemicals
by simple switching between DESI, voltage-free EASI, or LTP ionization
as well as to freely move the interface over a surface of interest.
A mini camera, which is mounted on the tip of the pen, magnifies the
desorption area and enables a simple positioning of the pen. The interface
was successfully tested using different types of chemicals, pharmaceuticals,
and real life samples. Moreover, the combination of optical data from
the camera module and chemical data obtained by mass analysis facilitates
a novel type of imaging mass spectrometry, which we name “interactive
mass spectrometry imaging (IMSI)”.
Collapse
Affiliation(s)
- Christina Meisenbichler
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| | - Florian Kluibenschedl
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| | - Thomas Müller
- Institute of Organic Chemistry, Leopold-Franzens University Innsbruck, 6020 Innsbruck, Austria
| |
Collapse
|
31
|
Brown HM, McDaniel TJ, Fedick PW, Mulligan CC. The current role of mass spectrometry in forensics and future prospects. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3974-3997. [PMID: 32720670 DOI: 10.1039/d0ay01113d] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Mass spectrometry (MS) techniques are highly prevalent in crime laboratories, particularly those coupled to chromatographic separations like gas chromatography (GC) and liquid chromatography (LC). These methods are considered "gold standard" analytical techniques for forensic analysis and have been extensively validated for producing prosecutorial evidentiary data. However, factors such as growing evidence backlogs and problematic evidence types (e.g., novel psychoactive substance (NPS) classes) have exposed limitations of these stalwart techniques. This critical review serves to delineate the current role of MS methods across the broad sub-disciplines of forensic science, providing insight on how governmental steering committees guide their implementation. Novel, developing techniques that seek to broaden applicability and enhance performance will also be highlighted, from unique modifications to traditional hyphenated MS methods to the newer "ambient" MS techniques that show promise for forensic analysis, but need further validation before incorporation into routine forensic workflows. This review also expounds on how recent improvements to MS instrumental design, scan modes, and data processing could cause a paradigm shift in how the future forensic practitioner collects and processes target evidence.
Collapse
Affiliation(s)
- Hilary M Brown
- Chemistry Division, Research Department, Naval Air Warfare Center, Weapons Division (NAWCWD), United States Navy Naval Air Systems Command (NAVAIR), China Lake, California 93555, USA.
| | | | | | | |
Collapse
|