1
|
Nelson BJ, Kc P, Badal A, Jiang L, Masters SC, Zeng R. Pediatric evaluations for deep learning CT denoising. Med Phys 2024; 51:978-990. [PMID: 38127330 DOI: 10.1002/mp.16901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 11/13/2023] [Accepted: 12/04/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND Deep learning (DL) CT denoising models have the potential to improve image quality for lower radiation dose exams. These models are generally trained with large quantities of adult patient image data. However, CT, and increasingly DL denoising methods, are used in both adult and pediatric populations. Pediatric body habitus and size can differ significantly from adults and vary dramatically from newborns to adolescents. Ensuring that pediatric subgroups of different body sizes are not disadvantaged by DL methods requires evaluations capable of assessing performance in each subgroup. PURPOSE To assess DL CT denoising in pediatric and adult-sized patients, we built a framework of computer simulated image quality (IQ) control phantoms and evaluation methodology. METHODS The computer simulated IQ phantoms in the framework featured pediatric-sized versions of standard CatPhan 600 and MITA-LCD phantoms with a range of diameters matching the mean effective diameters of pediatric patients ranging from newborns to 18 years old. These phantoms were used in simulating CT images that were then inputs for a DL denoiser to evaluate performance in different sized patients. Adult CT test images were simulated using standard-sized phantoms scanned with adult scan protocols. Pediatric CT test images were simulated with pediatric-sized phantoms and adjusted pediatric protocols. The framework's evaluation methodology consisted of denoising both adult and pediatric test images then assessing changes in image quality, including noise, image sharpness, CT number accuracy, and low contrast detectability. To demonstrate the use of the framework, a REDCNN denoising model trained on adult patient images was evaluated. To validate that the DL model performance measured with the proposed pediatric IQ phantoms was representative of performance in more realistic patient anatomy, anthropomorphic pediatric XCAT phantoms of the same age range were also used to compare noise reduction performance. RESULTS Using the proposed pediatric-sized IQ phantom framework, size differences between adult and pediatric-sized phantoms were observed to substantially influence the adult trained DL denoising model's performance. When applied to adult images, the DL model achieved a 60% reduction in noise standard deviation without substantial loss in sharpness in mid or high spatial frequencies. However, in smaller phantoms the denoising performance dropped due to different image noise textures resulting from the smaller field of view (FOV) between adult and pediatric protocols. In the validation study, noise reduction trends in the pediatric-sized IQ phantoms were found to be consistent with those found in anthropomorphic phantoms. CONCLUSION We developed a framework of using pediatric-sized IQ phantoms for pediatric subgroup evaluation of DL denoising models. Using the framework, we found the performance of an adult trained DL denoiser did not generalize well in the smaller diameter phantoms corresponding to younger pediatric patient sizes. Our work suggests noise texture differences from FOV changes between adult and pediatric protocols can contribute to poor generalizability in DL denoising and that the proposed framework is an effective means to identify these performance disparities for a given model.
Collapse
Affiliation(s)
- Brandon J Nelson
- Center for Devices and Radiological Health, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Prabhat Kc
- Center for Devices and Radiological Health, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Andreu Badal
- Center for Devices and Radiological Health, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Lu Jiang
- Center for Devices and Radiological Health, Office of Product Evaluation and Quality, Office of Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Shane C Masters
- Center for Drug Evaluation and Research, Office of Specialty Medicine, Division of Imaging and Radiation Medicine, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | - Rongping Zeng
- Center for Devices and Radiological Health, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| |
Collapse
|
2
|
Monnin P, Damet J, Bosmans H, Marshall NW. Task-based detectability in anatomical background in digital mammography, digital breast tomosynthesis and synthetic mammography. Phys Med Biol 2024; 69:025017. [PMID: 38214048 DOI: 10.1088/1361-6560/ad1766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 12/20/2023] [Indexed: 01/13/2024]
Abstract
Objective.Determining the detectability of targets for the different imaging modalities in mammography in the presence of anatomical background noise is challenging. This work proposes a method to compare the image quality and detectability of targets in digital mammography (DM), digital breast tomosynthesis (DBT) and synthetic mammography.Approach. The low-frequency structured noise produced by a water phantom with acrylic spheres was used to simulate anatomical background noise for the different types of images. A method was developed to apply the non-prewhitening observer model with eye filter (NPWE) in these conditions. A homogeneous poly(methyl) methacrylate phantom with a 0.2 mm thick aluminium disc was used to calculate 2D in-plane modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta, and system detective quantum efficiency for 30, 50 and 70 mm thicknesses. The in-depth MTFs of DBT volumes were determined using a thin tungsten wire. The MTF, system NPS and anatomical NPS were used in the NPWE model to calculate the threshold gold thickness of the gold discs contained in the CDMAM phantom, which was taken as reference. Main results.The correspondence between the NPWE model and the CDMAM phantom (linear Pearson correlation 0.980) yielded a threshold detectability index that was used to determine the threshold diameter of spherical microcalcifications and masses. DBT imaging improved the detection of masses, which depended mostly on the reduction of anatomical background noise. Conversely, DM images yielded the best detection of microcalcifications.Significance.The method presented in this study was able to quantify image quality and object detectability for the different imaging modalities and levels of anatomical background noise.
Collapse
Affiliation(s)
- P Monnin
- Institute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - J Damet
- Institute of radiation physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland
| | - H Bosmans
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, 3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| | - N W Marshall
- UZ Gasthuisberg, Department of Radiology, Herestraat 49, 3000 Leuven, Belgium
- Medical Imaging Research Center, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, 3000 Leuven, Belgium
| |
Collapse
|
3
|
Kim G, Baek J. Power-law spectrum-based objective function to train a generative adversarial network with transfer learning for the synthetic breast CT image. Phys Med Biol 2023; 68:205007. [PMID: 37722388 DOI: 10.1088/1361-6560/acfadf] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 09/18/2023] [Indexed: 09/20/2023]
Abstract
Objective.This paper proposes a new objective function to improve the quality of synthesized breast CT images generated by the GAN and compares the GAN performances on transfer learning datasets from different image domains.Approach.The proposed objective function, named beta loss function, is based on the fact that x-ray-based breast images follow the power-law spectrum. Accordingly, the exponent of the power-law spectrum (beta value) for breast CT images is approximately two. The beta loss function is defined in terms of L1 distance between the beta value of synthetic images and validation samples. To compare the GAN performances for transfer learning datasets from different image domains, ImageNet and anatomical noise images are used in the transfer learning dataset. We employ styleGAN2 as the backbone network and add the proposed beta loss function. The patient-derived breast CT dataset is used as the training and validation dataset; 7355 and 212 images are used for network training and validation, respectively. We use the beta value evaluation and Fréchet inception distance (FID) score for quantitative evaluation.Main results.For qualitative assessment, we attempt to replicate the images from the validation dataset using the trained GAN. Our results show that the proposed beta loss function achieves a more similar beta value to real images and a lower FID score. Moreover, we observe that the GAN pretrained with anatomical noise images achieves better equality than ImageNet for beta value evaluation and FID score. Finally, the beta loss function with anatomical noise as the transfer learning dataset achieves the lowest FID score.Significance.Overall, the GAN using the proposed beta loss function with anatomical noise images as the transfer learning dataset provides the lowest FID score among all tested cases. Hence, this work has implications for developing GAN-based breast image synthesis methods for medical imaging applications.
Collapse
Affiliation(s)
- Gihun Kim
- School of Integrated Technology, Yonsei University, Republic of Korea
| | - Jongduk Baek
- Department of Artificial Intelligence, Yonsei University, Republic of Korea
- Baruenex Imaging, Republic of Korea
| |
Collapse
|
4
|
Makeev A, Glick SJ. Task-based assessment of digital mammography microcalcification detection with deep learning denoising algorithmss using in silico and physical phantom studies. J Med Imaging (Bellingham) 2023; 10:053502. [PMID: 37808969 PMCID: PMC10557039 DOI: 10.1117/1.jmi.10.5.053502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 08/15/2023] [Accepted: 09/19/2023] [Indexed: 10/10/2023] Open
Abstract
Purpose Recent research suggests that image quality degradation with reduced radiation exposure in mammography can be mitigated by postprocessing mammograms with denoising algorithms based on convolutional neural networks. Breast microcalcifications, along with extended soft-tissue lesions, are the primary breast cancer biomarkers in a clinical x-ray examination, with the former being more sensitive to quantum noise. We test one such publicly available denoising method to observe if an improvement in detection of small microcalcifications can be achieved when deep learning-based denoising is applied to half-dose phantom scans. Approach An existing denoiser model (that was previously trained on clinical data) was applied to mammograms of an anthropomorphic physical phantom with hydroxyapatite microcalcifications. In addition, another model trained and tested using all synthetic (Monte Carlo) data was applied to a similar digital compressed breast phantom. Human reader studies were conducted to assess and compare image quality in a set of binary signal detection 4-AFC experiments, with proportion of correct responses used as a performance metric. Results In both physical phantom/clinical system and simulation studies, we saw no apparent improvement in small microcalcification signal detection in denoised half-dose mammograms. However, in a Monte Carlo study, we observed a noticeable jump in 4-AFC scores, when readers analyzed denoised half-dose images processed by the neural network trained on a dataset composed of 50% signal-present (SP) and 50% signal-absent regions of interest (ROIs). Conclusions Our findings conjecture that deep-learning denoising algorithms may benefit from enriching training datasets with SP ROIs, at least in cases with clusters of 5 to 10 microcalcifications, each of size ≲ 240 μ m .
Collapse
Affiliation(s)
- Andrey Makeev
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Stephen J. Glick
- Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
5
|
Morsink CF, Dam-Vervloet AJ, Krommendijk ME, Kaya M, Cuartas-Vélez C, Knop T, Francis KJ, Bosschaart N. Design and characterization of color printed polyurethane films as biomedical phantom layers. BIOMEDICAL OPTICS EXPRESS 2023; 14:4485-4506. [PMID: 37791261 PMCID: PMC10545194 DOI: 10.1364/boe.491695] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/30/2023] [Accepted: 07/05/2023] [Indexed: 10/05/2023]
Abstract
We propose a new, user-friendly and accessible approach for fabricating thin phantoms with controllable absorption properties in magnitude, spectral shape, and spatial distribution. We utilize a standard office laser color printer to print on polyurethane thin films (40 - 60 μm), commonly available as medical film dressings and ultrasound probe covers. We demonstrate that the optical attenuation and absorption of the printed films correlate linearly with the printer input settings (opacity), which facilitates a systematic phantom design. The optical and acoustic properties of these polyurethane films are similar to biological tissue. We argue that these thin phantoms are applicable to a wide range of biomedical applications. Here, we introduce two potential applications: (1) homogeneous epidermal melanin phantoms and (2) spatially resolved absorbers for photoacoustic imaging. We characterize the thin phantoms in terms of optical properties, thickness, microscopic structure, and reproducibility of the printing process.
Collapse
Affiliation(s)
- Claudia F. Morsink
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Alida J. Dam-Vervloet
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
- Medical Physics Department, Isala Hospital, Zwolle, The Netherlands
| | - Marleen E. Krommendijk
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Michael Kaya
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Carlos Cuartas-Vélez
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Tom Knop
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Kalloor Joseph Francis
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| | - Nienke Bosschaart
- Biomedical Photonic Imaging Group, Technical Medical Center, University of Twente, The Netherlands
| |
Collapse
|
6
|
Bach M, Aberle C, Depeursinge A, Jimenez-Del-Toro O, Schaer R, Flouris K, Konukoglu E, Müller H, Stieltjes B, Obmann MM. 3D-printed iodine-ink CT phantom for radiomics feature extraction - advantages and challenges. Med Phys 2023; 50:5682-5697. [PMID: 36945890 DOI: 10.1002/mp.16373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 02/07/2023] [Accepted: 02/20/2023] [Indexed: 03/23/2023] Open
Abstract
BACKGROUND To test and validate novel CT techniques, such as texture analysis in radiomics, repeat measurements are required. Current anthropomorphic phantoms lack fine texture and true anatomic representation. 3D-printing of iodinated ink on paper is a promising phantom manufacturing technique. Previously acquired or artificially created CT data can be used to generate realistic phantoms. PURPOSE To present the design process of an anthropomorphic 3D-printed iodine ink phantom, highlighting the different advantages and pitfalls in its use. To analyze the phantom's X-ray attenuation properties, and the influences of the printing process on the imaging characteristics, by comparing it to the original input dataset. METHODS Two patient CT scans and artificially generated test patterns were combined in a single dataset for phantom printing and cropped to a size of 26 × 19 × 30 cm3 . This DICOM dataset was printed on paper using iodinated ink. The phantom was CT-scanned and compared to the original image dataset used for printing the phantom. The water-equivalent diameter of the phantom was compared to that of a patient cohort (N = 104). Iodine concentrations in the phantom were measured using dual-energy CT. 86 radiomics features were extracted from 10 repeat phantom scans and the input dataset. Features were compared using a histogram analysis and a PCA individually and overall, respectively. The frequency content was compared using the normalized spectrum modulus. RESULTS Low density structures are depicted incorrectly, while soft tissue structures show excellent visual accordance with the input dataset. Maximum deviations of around 30 HU between the original dataset and phantom HU values were observed. The phantom has X-ray attenuation properties comparable to a lightweight adult patient (∼54 kg, BMI 19 kg/m2 ). Iodine concentrations in the phantom varied between 0 and 50 mg/ml. PCA of radiomics features shows different tissue types separate in similar areas of PCA representation in the phantom scans as in the input dataset. Individual feature analysis revealed systematic shift of first order radiomics features compared to the original dataset, while some higher order radiomics features did not. The normalized frequency modulus |f(ω)| of the phantom data agrees well with the original data. However, all frequencies systematically occur more frequently in the phantom compared to the maximum of the spectrum modulus than in the original data set, especially for mid-frequencies (e.g., for ω = 0.3942 mm-1 , |f(ω)|original = 0.09 * |fmax |original and |f(ω)|phantom = 0.12 * |fmax |phantom ). CONCLUSIONS 3D-iodine-ink-printing technology can be used to print anthropomorphic phantoms with a water-equivalent diameter of a lightweight adult patient. Challenges include small residual air enclosures and the fidelity of HU values. For soft tissue, there is a good agreement between the HU values of the phantom and input data set. Radiomics texture features of the phantom scans are similar to the input data set, but systematic shifts of radiomics features in first order features, due to differences in HU values, need to be considered. The paper substrate influences the spatial frequency distribution of the phantom scans. This phantom type is of very limited use for dual-energy CT analyses.
Collapse
Affiliation(s)
- Michael Bach
- Clinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Christoph Aberle
- Clinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Adrien Depeursinge
- University of Applied Sciences Western Switzerland (HES-SO) Valais, Sierre, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland
| | | | - Roger Schaer
- University of Applied Sciences Western Switzerland (HES-SO) Valais, Sierre, Switzerland
| | | | | | - Henning Müller
- University of Applied Sciences Western Switzerland (HES-SO) Valais, Sierre, Switzerland
- Faculty of Medicine, University of Geneva (UNIGE), Geneva, Switzerland
| | - Bram Stieltjes
- Clinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Markus M Obmann
- Clinic of Radiology and Nuclear Medicine, University Hospital Basel, University of Basel, Basel, Switzerland
| |
Collapse
|
7
|
Zhang C, Fu J. A new breast phantom suitable for digital mammography, contrast-enhanced digital mammography and digital breast tomosynthesis. Phys Med Biol 2023; 68. [PMID: 36696693 DOI: 10.1088/1361-6560/acb636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 01/25/2023] [Indexed: 01/26/2023]
Abstract
Our objective is to report a new breast phantom that provides the objective assessment for three types of clinical mammography, i.e. digital mammography (DM), contrast-enhanced digital mammography (CEDM), and digital breast tomosynthesis (DBT). The tissue-equivalent materials are used to represent the corresponding tissue, and the layer-by-layer structure with separate regions is designed for image quality assessment of different mammography modes. For DM imaging, substitutes for microcalcifications and fibroglandular tissue of different sizes are used to simulate the conventional breast. For CEDM imaging, the tumor module that can be injected with imaging contrast agents is adopted to distinguish normal tissue and diseased tissue in the dense breast. For DBT imaging, the overlapping breast mass module with multiple layers is designed to perform the layer-by-layer imaging of overlapping tissue. In addition, the quantitative assessment module of image quality is designed based on contrast-to-noise ratio, modulation transfer function and artifact spread function. This phantom allows image quality to be evaluated objectively for three different types of the clinical mammography, while it provides an effective tool for optimizing the dose-image quality relationship of patients.
Collapse
Affiliation(s)
- Changsheng Zhang
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100190, People's Republic of China
| | - Jian Fu
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100190, People's Republic of China.,Jiangxi Research Institute, Beihang University, Nanchang, 330000, People's Republic of China.,Ningbo Institute of Technology, Beihang University, Ningbo, 315000, People's Republic of China
| |
Collapse
|
8
|
Ikejimba L, Farooqui A, Ghazi P. Hyperia: A novel methodology of developing anthropomorphic breast phantoms for X-ray imaging modalities - Part I: Concept and initial findings. Med Phys 2023; 50:702-718. [PMID: 36273400 PMCID: PMC9931645 DOI: 10.1002/mp.16045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 09/06/2022] [Accepted: 10/04/2022] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To introduce a novel methodology for developing anthropomorphic breast phantoms for use in X-ray-based imaging modalities. METHODS "Hyperization" is a quasi-stippling mapping operation in which regions of varying grayscale values in a 2D image are transformed into regions of varying holes on a surface. The holes can be cut or engraved on the sheet of paper using a high-resolution laser cutter/engraver. In hyperization, the main parameters are the size and the distance between the holes. Here, we introduce the concept and chronicle the development and characterization of a proof-of-concept prototype. In this study, we hypothesized that a resulting "Hyperia" phantom would be a realistic representative of a patient's breast tissue: it would exhibit similar X-ray properties and show textural complexities. We used breast computed tomography (bCT) images of real patients as the input models. Using a previously developed segmentation method, the input CT images were segmented into different tissue classes (skin, adipose, and fibroglandular). The segmented images were then "Hyperized". A series of Monte Carlo simulations were conducted to find the optimal hyperization parameters. Different laser cutter/engraver systems and substrate materials were explored to find a viable option for developing an entire Hyperia breast phantom. The resulting phantom was imaged on a prototype breast CT system, and the resulting images were evaluated based on physical properties and similarity to the original patient data. RESULTS The simulation results indicate close similarities - both in the distribution of different tissue types and the resulting CT numbers - between the patient bCT image and the bCT of the Hyperia phantom, regardless of the breast size and density: the Pearson correlation coefficient (ρ) ranged from 0.88 in a BIRADS A breast to 0.94 in BIRADS C and D breasts (ρ of 1.00 suggests perfect structural similarity), and the volumetric mean squared error ranged from 0.0033 (in BIRADS D breast) to 0.0059 (in BIRADS A), suggesting good agreement between the resulting CT numbers. For fabricating the slices, the office paper was found to be an optimal substrate material, with the Hyperization parameters of (α, β) = (0.200 mm, 0.400 mm). CONCLUSION A novel phantom can be used for X-ray-based breast cancer imaging systems. The main advantage is that only one material is used for creating a contrast between different tissue types in an image.
Collapse
|
9
|
Okkalidis N, Bliznakova K. A voxel-by-voxel method for mixing two filaments during a 3D printing process for soft-tissue replication in an anthropomorphic breast phantom. Phys Med Biol 2022; 67. [PMID: 36541511 DOI: 10.1088/1361-6560/aca640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 11/25/2022] [Indexed: 11/26/2022]
Abstract
Objective. In this study, a novel voxel-by-voxel mixing method is presented, according to which two filaments of different material are combined during the three dimensional (3D) printing process.Approach. In our approach, two types of filaments were used for the replication of soft-tissues, a polylactic acid (PLA) filament and a polypropylene (PP) filament. A custom-made software was used, while a series of breast patient CT scan images were directly associated to the 3D printing process. Each phantom´s layer was printed twice, once with the PLA filament and a second time with the PP filament. For each material, the filament extrusion rate was controlled voxel-by-voxel and was based on the Hounsfield units (HU) of the imported CT images. The phantom was scanned at clinical CT, breast tomosynthesis and micro CT facilities, as the major processing was performed on data from the CT. A side by side comparison between patient´s and phantom´s CT slices by means of profile and histogram comparison was accomplished. Further, in case of profile comparison, the Pearson´s coefficients were calculated.Main results. The visual assessment of the distribution of the glandular tissue in the CT slices of the printed breast anatomy showed high degree of radiological similarity to the corresponding patient´s glandular distribution. The profile plots´ comparison showed that the HU of the replicated and original patient soft tissues match adequately. In overall, the Pearson´s coefficients were above 0.91, suggesting a close match of the CT images of the phantom with those of the patient. The overall HU were close in terms of HU ranges. The HU mean, median and standard deviation of the original and the phantom CT slices were -149, -167, ±65 and -121, -130, ±91, respectively.Significance. The results suggest that the proposed methodology is appropriate for manufacturing of anthropomorphic soft tissue phantoms for x-ray imaging and dosimetry purposes, since it may offer an accurate replication of these tissues.
Collapse
Affiliation(s)
- Nikiforos Okkalidis
- Research Institute, Medical University of Varna, Bulgaria.,Morphé, Praxitelous 1, Thessaloniki, Greece
| | - Kristina Bliznakova
- Department of Medical Equipment, Electronic and Information Technologies in Healthcare, Medical University of Varna, Varna, Bulgaria
| |
Collapse
|
10
|
Physical and digital phantoms for 2D and 3D x-ray breast imaging: Review on the state-of-the-art and future prospects. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Marshall NW, Bosmans H. Performance evaluation of digital breast tomosynthesis systems: physical methods and experimental data. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac9a35] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Accepted: 10/13/2022] [Indexed: 11/17/2022]
Abstract
Abstract
Digital breast tomosynthesis (DBT) has become a well-established breast imaging technique, whose performance has been investigated in many clinical studies, including a number of prospective clinical trials. Results from these studies generally point to non-inferiority in terms of microcalcification detection and superior mass-lesion detection for DBT imaging compared to digital mammography (DM). This modality has become an essential tool in the clinic for assessment and ad-hoc screening but is not yet implemented in most breast screening programmes at a state or national level. While evidence on the clinical utility of DBT has been accumulating, there has also been progress in the development of methods for technical performance assessment and quality control of these imaging systems. DBT is a relatively complicated ‘pseudo-3D’ modality whose technical assessment poses a number of difficulties. This paper reviews methods for the technical performance assessment of DBT devices, starting at the component level in part one and leading up to discussion of system evaluation with physical test objects in part two. We provide some historical and basic theoretical perspective, often starting from methods developed for DM imaging. Data from a multi-vendor comparison are also included, acquired under the medical physics quality control protocol developed by EUREF and currently being consolidated by a European Federation of Organisations for Medical Physics working group. These data and associated methods can serve as a reference for the development of reference data and provide some context for clinical studies.
Collapse
|
12
|
Mettivier G, Sarno A, Varallo A, Russo P. Attenuation coefficient in the energy range 14–36 keV of 3D printing materials for physical breast phantoms. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac8966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 08/12/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. To measure the monoenergetic x-ray linear attenuation coefficient, μ, of fused deposition modeling (FDM) colored 3D printing materials (ABS, PLAwhite, PLAorange, PET and NYLON), used as adipose, glandular or skin tissue substitutes for manufacturing physical breast phantoms. Approach. Attenuation data (at 14, 18, 20, 24, 28, 30 and 36 keV) were acquired at Elettra synchrotron radiation facility, with step-wedge objects, using the Lambert–Beer law and a CCD imaging detector. Test objects were 3D printed using the Ultimaker 3 FDM printer. PMMA, Nylon-6 and high-density polyethylene step objects were also investigated for the validation of the proposed methodology. Printing uniformity was assessed via monoenergetic and polyenergetic imaging (32 kV, W/Rh). Main results. Maximum absolute deviation of μ for PMMA, Nylon-6 and HD-PE was 5.0%, with reference to literature data. For ABS and NYLON, μ differed by less than 6.1% and 7.1% from that of adipose tissue, respectively; for PET and PLAorange the difference was less than 11.3% and 6.3% from glandular tissue, respectively. PLAorange is a good substitute of skin (differences from −9.4% to +1.2%). Hence, ABS and NYLON filaments are suitable adipose tissue substitutes, while PET and PLAorange mimick the glandular tissue. PLAwhite could be printed at less than 100% infill density for matching the attenuation of glandular tissue, using the measured density calibration curve. The printing mesh was observed for sample thicknesses less than 60 mm, imaged in the direction normal to the printing layers. Printing dimensional repeatability and reproducibility was less 1%. Significance. For the first time an experimental determination was provided of the linear attenuation coefficient of common 3D printing filament materials with estimates of μ at all energies in the range 14–36 keV, for their use in mammography, breast tomosynthesis and breast computed tomography investigations.
Collapse
|
13
|
Okkalidis N. 3D printing methods for radiological anthropomorphic phantoms. Phys Med Biol 2022; 67. [PMID: 35830787 DOI: 10.1088/1361-6560/ac80e7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Accepted: 07/13/2022] [Indexed: 01/06/2023]
Abstract
Three dimensional (3D) printing technology has been widely evaluated for the fabrication of various anthropomorphic phantoms during the last couple of decades. The demand for such high quality phantoms is constantly rising and gaining an ever-increasing interest. Although, in a short time 3D printing technology provided phantoms with more realistic features when compared to the previous conventional methods, there are still several aspects to be explored. One of these aspects is the further development of the current 3D printing methods and software devoted to radiological applications. The current 3D printing software and methods usually employ 3D models, while the direct association of medical images with the 3D printing process is needed in order to provide results of higher accuracy and closer to the actual tissues' texture. Another aspect of high importance is the development of suitable printing materials. Ideally, those materials should be able to emulate the entire range of soft and bone tissues, while still matching the human's anatomy. Five types of 3D printing methods have been mainly investigated so far: (a) solidification of photo-curing materials; (b) deposition of melted plastic materials; (c) printing paper-based phantoms with radiopaque ink; (d) melting or binding plastic powder; and (e) bio-printing. From the first and second category, polymer jetting technology and fused filament fabrication (FFF), also known as fused deposition modelling (FDM), are the most promising technologies for the fulfilment of the requirements of realistic and radiologically equivalent anthropomorphic phantoms. Another interesting approach is the fabrication of radiopaque paper-based phantoms using inkjet printers. Although, this may provide phantoms of high accuracy, the utilized materials during the fabrication process are restricted to inks doped with various contrast materials. A similar condition applies to the polymer jetting technology, which despite being quite fast and very accurate, the utilized materials are restricted to those capable of polymerization. The situation is better for FFF/FDM 3D printers, since various compositions of plastic filaments with external substances can be produced conveniently. Although, the speed and accuracy of this 3D printing method are lower compared to the others, the relatively low-cost, constantly improving resolution, sufficient printing volume and plethora of materials are quite promising for the creation of human size heterogeneous phantoms and their adaptation to the treatment procedures of patients in the current health systems.
Collapse
Affiliation(s)
- Nikiforos Okkalidis
- Research Institute, Medical University of Varna, Bulgaria.,Morphé, Praxitelous 1, Thessaloniki, Greece
| |
Collapse
|
14
|
Amanova N, Martin J, Elster C. Explainability for deep learning in mammography image quality assessment. MACHINE LEARNING: SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1088/2632-2153/ac7a03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
The application of deep learning has recently been proposed for the assessment of image quality in mammography. It was demonstrated in a proof-of-principle study that the proposed approach can be more efficient than currently applied automated conventional methods. However, in contrast to conventional methods, the deep learning approach has a black-box nature and, before it can be recommended for the routine use, it must be understood more thoroughly. For this purpose, we propose and apply a new explainability method: the oriented, modified integrated gradients (OMIG) method. The design of this method is inspired by the integrated gradientsmethod but adapted considerably to the use case at hand. To further enhance this method, an upsampling technique is developed that produces high-resolution explainability maps for the downsampled data used by the deep learning approach. Comparison with established explainability methods demonstrates that the proposed approach yields substantially more expressive and informative results for our specific use case. Application of the proposed explainability approach generally confirms the validity of the considered deep learning-based mammography image quality assessment (IQA) method. Specifically, it is demonstrated that the predicted image quality is based on a meaningful mapping that makes successful use of certain geometric structures of the images. In addition, the novel explainability method helps us to identify the parts of the employed phantom that have the largest impact on the predicted image quality, and to shed some light on cases in which the trained neural networks fail to work as expected. While tailored to assess a specific approach from deep learning for mammography IQA, the proposed explainability method could also become relevant in other, similar deep learning applications based on high-dimensional images.
Collapse
|
15
|
Wang J, Falkson SR, Guo HH. Radiopaque Recreations of Lung Pathologies From Clinical Computed Tomography Images Using Potassium Iodide Inkjet 3-dimensional Printing: Proof of Concept. J Thorac Imaging 2022; 37:146-153. [PMID: 34334783 DOI: 10.1097/rti.0000000000000607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The purpose of this study was to develop a 3-dimensional (3D) printing method to create computed tomography (CT) realistic phantoms of lung cancer nodules and lung parenchymal disease from clinical CT images. MATERIALS AND METHODS Low-density paper was used as substrate material for inkjet printing with potassium iodide solution to reproduce phantoms that mimic the CT attenuation of lung parenchyma. The relationship between grayscale values and the corresponding CT numbers of prints was first established through the derivation of exponential fitted equation from scanning data. Next, chest CTs from patients with early-stage lung cancer and coronavirus disease 2019 (COVID-19) pneumonia were chosen for 3D printing. CT images of original lung nodule and the 3D-printed nodule phantom were compared based on pixel-to-pixel correlation and radiomic features. RESULTS CT images of part-solid lung cancer and 3D-printed nodule phantom showed both high visual similarity and quantitative correlation. R2 values from linear regressions of pixel-to-pixel correlations between 5 sets of patient and 3D-printed image pairs were 0.92, 0.94, 0.86, 0.85, and 0.83, respectively. Comparison of radiomic measures between clinical CT and printed models demonstrated 6.1% median difference, with 25th and 75th percentile range at 2.4% and 15.2% absolute difference, respectively. The densities and parenchymal morphologies from COVID-19 pneumonia CT images were well reproduced in the 3D-printed phantom scans. CONCLUSION The 3D printing method presented in this work facilitates creation of CT-realistic reproductions of lung cancer and parenchymal disease from individual patient scans with microbiological and pathology confirmation.
Collapse
Affiliation(s)
- Jia Wang
- Environmental Health and Safety, Stanford University
| | | | - H Henry Guo
- Department of Radiology, Stanford Medical Center, Palo Alto, CA
| |
Collapse
|
16
|
Vancoillie L, Cockmartin L, Marshall N, Bosmans H. The impact on lesion detection via a multi-vendor study: A phantom-based comparison of digital mammography, digital breast tomosynthesis, and synthetic mammography. Med Phys 2021; 48:6270-6292. [PMID: 34407213 DOI: 10.1002/mp.15171] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 07/27/2021] [Accepted: 07/27/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The aim of this study is to perform a test object-based comparison of the imaging performance of digital mammography (DM), digital breast tomosynthesis (DBT), and synthetic mammography (SM). METHODS Two test objects were used, the CDMAM and the L1-structured phantom. Small-detail detectability was assessed using CDMAM and the microcalcification simulating specks in the L1-structured background. Detection of spiculated and non-spiculated mass-like objects was assessed using the L1 phantom. Six different systems were included: Amulet Innovality (Fujifilm), Senographe Pristina (GEHC), 3Dimensions (Hologic), Giotto Class (IMS), Clarity 2D/3D (Planmed), and Mammomat Revelation (Siemens). Images were acquired under automatic exposure control (AEC) and at adjusted levels of AEC/2 and 2 × AEC level. Threshold gold thickness (Ttr ) was established for the 0.13-mm-diameter CDMAM discs. Threshold diameters for the calcifications (dtr_c ), the spiculated masses (dtr_sm ), and for the non-spiculated masses (dtr_nsm ) were established. The threshold condition was defined as the thickness or diameter for a 62.5% correct score. RESULTS Ttr for DM was generally superior to DBT, which in turn was superior to SM, but for most systems, these differences between modes were not significant. For L1, no significant differences in dtr_c were found between DM and DBT. The increase in dtr_c from DM to SM at AEC dose was 1%, 19%, 11%, 14%, 46%, and 27% for the Fujifilm, GEHC, Hologic, IMS, Planmed, and Siemens, respectively, indicating significantly poorer performance for all vendors except for Fujifilm, Hologic, and IMS. For both mass types, DBT performed better than SM, while SM showed no significant difference with DM (except for Fujifilm spiculated masses). The dose had an impact on small-detail detectability for both phantoms but did not influence the detection of either mass type. CONCLUSIONS Both phantoms indicated potentially reduced small-detail detectability for SM versus DM and DBT and should therefore not be used in stand-alone mode. The L1 phantom demonstrated no significant difference in microcalcification detection between DM and DBT and also demonstrated the superiority of DBT, compared to DM for mass detection, for all six systems.
Collapse
Affiliation(s)
- Liesbeth Vancoillie
- Department of Imaging and Pathology, KU Leuven, Division of Medical Physics & Quality Assessment, Leuven, Belgium
| | | | - Nicholas Marshall
- Department of Imaging and Pathology, KU Leuven, Division of Medical Physics & Quality Assessment, Leuven, Belgium.,Department of Radiology, UZ Leuven, Leuven, Belgium
| | - Hilde Bosmans
- Department of Imaging and Pathology, KU Leuven, Division of Medical Physics & Quality Assessment, Leuven, Belgium.,Department of Radiology, UZ Leuven, Leuven, Belgium
| |
Collapse
|
17
|
Kariyawasam LN, Ng CKC, Sun Z, Kealley CS. Use of Three-Dimensional Printing in Modelling an Anatomical Structure with a High Computed Tomography Attenuation Value: A Feasibility Study. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS 2021. [DOI: 10.1166/jmihi.2021.3664] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Introduction: Three-dimensional (3D) printing provides an opportunity to develop anthropomorphic computed tomography (CT) phantoms with anatomical and radiological features mimicking a range of patients’ conditions, thus allowing development of individualised, low dose
scanning protocols. However, previous studies of 3D printing in CT phantom development could only create anatomical structures using potassium iodide with attenuation values up to 1200 HU which is insufficient to mimic the radiological features of some high attenuation structures such as cortical
bone. This study aimed at investigating the feasibility of using 3D printing in modelling cortical bone with a non-iodinated material. Methods: This study had 2 stages. Stage 1 involved a vat photopolymerisation 3D printer to directly print cube phantoms with different percentage compositions
of calcium phosphate (CP) and resin (approach 1), and approach 2 using a material extrusion 3D printer to develop a cube mould for infilling of the CP with hardener as the phantom. The approach able to create the cube phantom with the CT attenuation value close to that of a tibial mid-diaphysis
cortex of a real patient, 1475±205 HU was employed to develop a tibial mid-diaphysis phantom. The mean CT numbers of the cube and tibia phantoms were measured and compared with that of the original CT dataset through unpaired t-test. Results: All phantoms were scanned by CT using
a lower extremity scanning protocol. The moulding approach was selected to develop the tibia middiaphysis phantom with CT attenuation value, 1434±184 HU which was not statistically significantly different from the one of the original dataset (p = 0.721). Conclusion: This
study demonstrates the feasibility to use the material extrusion 3D printer to create a tibial mid-diaphysis mould for infilling of the CP as an anthropomorphic CT phantom and the attenuation value of its cortex matches the real patient’s one.
Collapse
Affiliation(s)
- Lakna N. Kariyawasam
- Discipline of Medical Radiation Science, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia 6845, Australia
| | - Curtise K. C. Ng
- Discipline of Medical Radiation Science, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia 6845, Australia
| | - Zhonghua Sun
- Discipline of Medical Radiation Science, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia 6845, Australia
| | - Catherine S. Kealley
- Discipline of Medical Radiation Science, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia 6845, Australia
| |
Collapse
|
18
|
Buytaert D, Taeymans Y, De Wolf D, Bacher K. Evaluation of a no-reference image quality metric for projection X-ray imaging using a 3D printed patient-specific phantom. Phys Med 2021; 89:29-40. [PMID: 34343764 DOI: 10.1016/j.ejmp.2021.07.011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 07/06/2021] [Accepted: 07/13/2021] [Indexed: 11/19/2022] Open
Abstract
PURPOSE Feasability of a no-reference image quality metric was assessed on patient-like images using a patient-specific phantom simulating a frame of a coronary angiogram. METHODS One background and one contrast-filled frame of a coronary angiogram, acquired using a clinical imaging protocol, were selected from a Philips Integris Allura FD (Philips Healthcare, Best, The Netherlands). The background frame's pixels were extruded to a thickness proportional to their grey value. One phantom was 3D printed using composite 80% bronze filament (max. thickness of 5.1 mm), the other was a custom PMMA cast (max thickness of 8.5 cm). A vessel mold was created from the contrast-filled frame and injected with a solution of 320 mg I/ml contrast fluid (75%), water and gelatin. Still X-ray frames of the vessel mold + background phantom + 16 cm PMMA were acquired at manually selected different exposure settings using a Philips Azurion (Philips Healthcare, Best, The Netherlands) in User Quality Control Mode and were exported as RAW images. The signal-difference-to-noise-ratio-squared (SDNR2) and a spatial-domain-equivalent of the noise equivalent quanta (NEQSDE) were calculated. The Spearman's correlation of the latter parameters with a no-reference perceptual image quality metric (NIQE) was investigated. RESULTS The bronze phantom showed better resemblance to the original patient frame selected from a coronary angiogram of an actual patient, with better contrast and less blur than the PMMA phantom. Both phantoms were imaged using a comparable imaging protocol to the one used to acquire the original frame. The bronze phantom was hence used together with the vessel mold for image quality measurements on the 165 still phantom frames. A strong correlation was noted between NEQSDE and NIQE (SROCC = -0.99, p < 0.0005) and between SDNR2 and NIQE (SROCC = -0.97, p < 0.0005). CONCLUSION Using a cost-effective and easy to realize patient-specific phantom we were able to generate patient-like X-ray frames. NIQE as a no-reference image quality model has the potential to predict physical image quality from patient images.
Collapse
Affiliation(s)
- Dimitri Buytaert
- Department of Human Structure and Repair, Ghent University, Ghent, Belgium.
| | - Yves Taeymans
- Heart Center, Ghent University Hospital, Ghent, Belgium.
| | - Daniël De Wolf
- Department of Paediatric Cardiology, Ghent University Hospital, Ghent, Belgium.
| | - Klaus Bacher
- Department of Human Structure and Repair, Ghent University, Ghent, Belgium.
| |
Collapse
|
19
|
Cruz-Bastida JP, Marshall EL, Reiser N, George J, Pearson EA, Feinstein KA, Al-Hallaq HA, Burton CS, Beaulieu D, MacDougall RD, Reiser I. Development of a neonate X-ray phantom for 2D imaging applications using single-tone inkjet printing. Med Phys 2021; 48:4944-4954. [PMID: 34255871 DOI: 10.1002/mp.15086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 04/16/2021] [Accepted: 06/17/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Inkjet printers can be used to fabricate anthropomorphic phantoms by the use of iodine-doped ink. However, challenges persist in implementing this technique. The calibration from grayscale to ink density is complex and time-consuming. The purpose of this work is to develop a printing methodology that requires a simpler calibration and is less dependent on printer characteristics to produce the desired range of x-ray attenuation values. METHODS Conventional grayscale printing was substituted by single-tone printing; that is, the superposition of pure black layers of iodinated ink. Printing was performed with a consumer-grade inkjet printer using ink made of potassium-iodide (KI) dissolved in water at 1 g/ml. A calibration for the attenuation of ink was measured using a commercial x-ray system at 70 kVp. A neonate radiograph obtained at 70 kVp served as an anatomical model. The attenuation map of the neonate radiograph was processed into a series of single-tone images. Single-tone images were printed, stacked, and imaged at 70 kVp. The phantom was evaluated by comparing attenuation values between the printed phantom and the original radiograph; attenuation maps were compared using the structural similarity index measure (SSIM), while attenuation histograms were compared using the Kullback-Leibler (KL) divergence. A region of interest (ROI)-based analysis was also performed, where the attenuation distribution within given ROIs was compared between phantom and patient. The phantom sharpness was evaluated in terms of modulation transfer function (MTF) estimates and signal spread profiles of high spatial resolution features in the image. RESULTS The printed phantom required 36 pages. The printing queue was automated and it took about 2 h to print the phantom. The radiograph of the printed phantom demonstrated a close resemblance to the original neonate radiograph. The SSIM of the phantom with respect to that of the patient was 0.53. Both patient and phantom attenuation histograms followed similar distributions, and the KL divergence between such histograms was 0.20. The ROI-based analysis showed that the largest deviations from patient attenuation values were observed at the higher and lower ends of the attenuation range. The limiting resolution of the proposed methodology was about 1 mm. CONCLUSION A methodology to generate a neonate phantom for 2D imaging applications, using single-tone printing, was developed. This method only requires a single-value calibration and required less than 2 h to print a complete phantom.
Collapse
Affiliation(s)
| | - Emily L Marshall
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Nikolaj Reiser
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Jonathan George
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Erik A Pearson
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Kate A Feinstein
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Hania A Al-Hallaq
- Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Christiane S Burton
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Danielle Beaulieu
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Robert D MacDougall
- Department of Radiology, Boston Children's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Ingrid Reiser
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| |
Collapse
|
20
|
Makeev A, Rodal G, Ghammraoui B, Badal A, Glick SJ. Exploring CNN potential in discriminating benign and malignant calcifications in conventional and dual-energy FFDM: simulations and experimental observations. J Med Imaging (Bellingham) 2021; 8:033501. [PMID: 34002162 DOI: 10.1117/1.jmi.8.3.033501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Accepted: 04/19/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Deep convolutional neural networks (CNN) have demonstrated impressive success in various image classification tasks. We investigated the use of CNNs to distinguish between benign and malignant microcalcifications, using either conventional or dual-energy mammography x-ray images. The two kinds of calcifications, known as type-I (calcium oxalate crystals) and type-II (calcium phosphate aggregations), have different attenuation properties in the mammographic energy range. However, variations in microcalcification shape, size, and density as well as compressed breast thickness and breast tissue background make this a challenging discrimination task for the human visual system. Approach: Simulations (conventional and dual-energy mammography) and phantom experiments (conventional mammography only) were conducted using the range of breast thicknesses and randomly shaped microcalcifications. The off-the-shelf Resnet-18 CNN was trained on the regions of interest with calcification clusters of the two kinds. Results: Both Monte Carlo simulations and experimental phantom data suggest that deep neural networks can be trained to separate the two classes of calcifications with high accuracy, using dual-energy mammograms. Conclusions: Our work shows the encouraging results of using the CNNs for non-invasive testing for type-I and type-II microcalcifications and may stimulate further research in this area with expanding presence of the novel breast imaging modalities like dual-energy mammography or systems using photon-counting detectors.
Collapse
Affiliation(s)
- Andrey Makeev
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Gabriela Rodal
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Bahaa Ghammraoui
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Andreu Badal
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Stephen J Glick
- Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
21
|
Ghammraoui B, Gkoumas S, Glick SJ. Characterization of a GaAs photon-counting detector for mammography. J Med Imaging (Bellingham) 2021; 8:033504. [PMID: 34179217 PMCID: PMC8217962 DOI: 10.1117/1.jmi.8.3.033504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 06/04/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: The purpose of this study was to evaluate the potential of a prototype gallium arsenide (GaAs) photon-counting detector (PCD) for imaging of the breast. Approach: First, the contrast-to-noise ratio (CNR) using different aluminum/poly(methyl methacrylate) (PMMA) phantoms of different thicknesses were measured. Second, microcalcification detection accuracy using a receiver operating characteristic study with three observers reading an ensemble of images was measured. Finally, the feasibility of using a GaAs system with two energy bins for contrast-enhanced mammography was investigated. Results: For the first two studies, the GaAs detector was compared with a commercial mammography system. The CNR was estimated by imaging 18-, 36-, and 110 - μ m -thick aluminum targets placed on top of 6 cm of PMMA plates and was found to be similar or better over a range of exposures. We observed a similar performance of detecting microcalcifications with the GaAs detector over a range of clinically applicable dose levels with a small increase at lower dose levels. The results also showed that contrast-enhanced spectral mammography using a GaAs PCD is feasible and beneficial. Conclusions: Results from this study suggest that performance with this new detector seems either slightly improved or equivalent to a commercial mammography system that used an energy-integrated detector. No attempt at optimizing exposure techniques for the GaAs detector was performed. Further research is needed to determine optimal acquisition parameters for the GaAs detector and to develop more sophisticated material decomposition algorithms that promise to provide improved quantitative estimates of iodine uptake.
Collapse
Affiliation(s)
- Bahaa Ghammraoui
- U.S. Food and Drug Administration, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | | | - Stephen J. Glick
- U.S. Food and Drug Administration, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| |
Collapse
|
22
|
Galstyan A, Bunker MJ, Lobo F, Sims R, Inziello J, Stubbs J, Mukhtar R, Kelil T. Applications of 3D printing in breast cancer management. 3D Print Med 2021; 7:6. [PMID: 33559793 PMCID: PMC7871648 DOI: 10.1186/s41205-021-00095-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 01/31/2021] [Indexed: 12/24/2022] Open
Abstract
Three-dimensional (3D) printing is a method by which two-dimensional (2D) virtual data is converted to 3D objects by depositing various raw materials into successive layers. Even though the technology was invented almost 40 years ago, a rapid expansion in medical applications of 3D printing has only been observed in the last few years. 3D printing has been applied in almost every subspecialty of medicine for pre-surgical planning, production of patient-specific surgical devices, simulation, and training. While there are multiple review articles describing utilization of 3D printing in various disciplines, there is paucity of literature addressing applications of 3D printing in breast cancer management. Herein, we review the current applications of 3D printing in breast cancer management and discuss the potential impact on future practices.
Collapse
Affiliation(s)
- Arpine Galstyan
- University of California, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA.,Department of Radiology, Center for Advanced 3D Technologies, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA
| | - Michael J Bunker
- University of California, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA.,Department of Radiology, Center for Advanced 3D Technologies, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA
| | - Fluvio Lobo
- University of Florida, 3100 Technology Pkwy, Orlando, FL, 32826, USA
| | - Robert Sims
- University of Florida, 3100 Technology Pkwy, Orlando, FL, 32826, USA
| | - James Inziello
- University of Florida, 3100 Technology Pkwy, Orlando, FL, 32826, USA
| | - Jack Stubbs
- University of Florida, 3100 Technology Pkwy, Orlando, FL, 32826, USA
| | - Rita Mukhtar
- University of California, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA.,Department of Surgery, University of California, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA
| | - Tatiana Kelil
- University of California, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA. .,Department of Radiology, Center for Advanced 3D Technologies, 1600 Divisadero St, C250, Box 1667, San Francisco, CA, 94115, USA.
| |
Collapse
|
23
|
Ikejimba LC, Salad J, Graff CG, Goodsitt M, Chan HP, Huang H, Zhao W, Ghammraoui B, Lo JY, Glick SJ. Assessment of task-based performance from five clinical DBT systems using an anthropomorphic breast phantom. Med Phys 2021; 48:1026-1038. [PMID: 33128288 DOI: 10.1002/mp.14568] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 09/07/2020] [Accepted: 10/18/2020] [Indexed: 12/30/2022] Open
Abstract
PURPOSE Digital breast tomosynthesis (DBT) is a limited-angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full-field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet-printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. METHOD A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5-mm spiculated masses fabricated with potassium iodide (KI)-doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. RESULTS For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. CONCLUSIONS This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet-printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.
Collapse
Affiliation(s)
- Lynda C Ikejimba
- US Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Jesse Salad
- US Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Christian G Graff
- US Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Mitchell Goodsitt
- Michigan Medicine, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, MI, 48109, USA
| | - Heang-Ping Chan
- Michigan Medicine, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, MI, 48109, USA
| | - Hailiang Huang
- Stony Brook Medicine, Stony Brook University, 101 Nicolls Road, Stony Brook, NY, 11794, USA
| | - Wei Zhao
- Stony Brook Medicine, Stony Brook University, 101 Nicolls Road, Stony Brook, NY, 11794, USA
| | - Bahaa Ghammraoui
- US Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Joseph Y Lo
- Medical Physics Graduate Program, Duke University, 2424 Erwin Road, Durham, NC, 27705, USA
| | - Stephen J Glick
- US Food and Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| |
Collapse
|
24
|
Bliznakova K. The advent of anthropomorphic three-dimensional breast phantoms for X-ray imaging. Phys Med 2020; 79:145-161. [DOI: 10.1016/j.ejmp.2020.11.025] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 11/16/2020] [Accepted: 11/19/2020] [Indexed: 10/22/2022] Open
|
25
|
Abstract
Breast cancer is one of the most common cancers worldwide, which makes it a very impactful malignancy in the society. Breast cancers can be classified through different systems based on the main tumor features and gene, protein, and cell receptors expression, which will determine the most advisable therapeutic course and expected outcomes. Multiple therapeutic options have already been proposed and implemented for breast cancer treatment. Nonetheless, their use and efficacy still greatly depend on the tumor classification, and treatments are commonly associated with invasiveness, pain, discomfort, severe side effects, and poor specificity. This has demanded an investment in the research of the mechanisms behind the disease progression, evolution, and associated risk factors, and on novel diagnostic and therapeutic techniques. However, advances in the understanding and assessment of breast cancer are dependent on the ability to mimic the properties and microenvironment of tumors in vivo, which can be achieved through experimentation on animal models. This review covers an overview of the main animal models used in breast cancer research, namely in vitro models, in vivo models, in silico models, and other models. For each model, the main characteristics, advantages, and challenges associated to their use are highlighted.
Collapse
|
26
|
Monnin P, Verdun FR, Bosmans H, Marshall NW. In-plane image quality and NPWE detectability index in digital breast tomosynthesis. Phys Med Biol 2020; 65:095013. [PMID: 32191923 DOI: 10.1088/1361-6560/ab8147] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A rigorous 2D analysis of signal and noise transfer applied to reconstructed planes in digital breast tomosynthesis (DBT) is necessary for system characterization and optimization. This work proposes a method for assessing technical image quality and system detective quantum efficiency (DQEsys) for reconstructed planes in DBT. Measurements of 2D in-plane modulation transfer function (MTF) and noise power spectrum (NPS) were made on five DBT systems using different acquisition parameters, reconstruction algorithms and plane spacing. This work develops the noise equivalent quanta (NEQ), DQEsys and detectability index (d') calculated using a non-prewhitening model observer with eye filter (NPWE) for reconstructed DBT planes. The images required for this implementation were acquired using a homogeneous test object of thickness 40 mm poly(methyl) methacrylate plus 0.5 mm Al; 2D MTF was calculated from an Al disc of thickness 0.2 mm and diameter 50 mm positioned within the phantom. The radiant contrast of the MTF disc and the air kerma at the system input were used as normalization factors. The NPWE detectability index was then compared to the in-plane contrast-detail (c-d) threshold measured using the CDMAM phantom. The MTF and NPS measured on the different systems showed a strong anisotropy, consistent with the cascaded models developed in the literature for DBT. Detectability indices calculated from the measured MTF and NPS successfully predicted changes in c-d detectability for details between 0.1 mm and 2.0 mm, for DBT plane spacings between 0.5 mm and 10 mm, and for air kerma values at the system input between 157 µGy and 1170 μGy. The linear Pearson correlation between the detectability index and threshold gold thickness of the CDMAM phantom was -0.996. The method implements a parametric means of assessing the technical image quality of reconstructed DBT planes, providing valuable information for optimization of DBT systems.
Collapse
Affiliation(s)
- P Monnin
- Institute of Radiation Physics (IRA), Lausanne University Hospital (CHUV) and University of Lausanne, Rue du Grand-Pré 1, 1007 Lausanne, Switzerland. Author to whom any correspondence should be addressed
| | | | | | | |
Collapse
|
27
|
BOLD signal simulation and fMRI quality control base on an active phantom: a preliminary study. Med Biol Eng Comput 2020; 58:831-842. [PMID: 32034636 PMCID: PMC7156364 DOI: 10.1007/s11517-020-02133-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 01/21/2020] [Indexed: 11/23/2022]
Abstract
Blood-oxygen-level-dependent (BOLD) signal has been commonly used in functional magnetic resonance imaging (fMRI) to observe the activity in different areas of the brain or other organs. This signal is difficult to simulate, because its amplitude is nearly 1~3% and it is influenced by multiple factors. This study aimed to design and construct an active BOLD simulation phantom and test its stability and repeatability. The phantom consisted of two perpendicular loops. The BOLD signal was simulated by different stimuli generated by a regular periodic vibration current and transmission loops. Three scanners (Siemens skyra 3.0 T, Siemens verio 3.0 T, and GE signa HD 1.5 T) were used to test the stability and repeatability of the BOLD signal detection of the phantom. The percent signal change (PSC) was calculated for each stimulus. At baseline, the phantom exhibited stability, and the average signal variation was below 1% as revealed by the three scanners. The SNR of ROIs with different sizes were markedly high, being 2326.58 and 2389.24; and the ghosting ratio were 0.39% and 0.38%, and the stimuli detection efficiency for Siemens verio and Siemens skyra was 60% and 75%, respectively. The repeated scans of the same scanner for different stimuli were highly reproducible. In the three scanners, the PSC at the same location varied from nearly 1 to 3%. The areas activated on the phantom revealed by different scanners were comparatively consistent. The phantom designed for fMRI quantitative quality control displays good adaptability to different scanners and is easy to operate. It can reliably collect data by simple data processing. fMRI phantom testing process ![]()
Collapse
|
28
|
Comparative analysis of the transmission properties of tissue equivalent materials. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.04.050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
29
|
Feradov F, Marinov S, Bliznakova K. Physical Breast Phantom Dedicated for Mammography Studies. IFMBE PROCEEDINGS 2020. [DOI: 10.1007/978-3-030-31635-8_41] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
30
|
Characterization and applicability of low-density materials for making 3D physical anthropomorphic breast phantoms. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.108361] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
31
|
Schopphoven S, Cavael P, Bock K, Fiebich M, Mäder U. Breast phantoms for 2D digital mammography with realistic anatomical structures and attenuation characteristics based on clinical images using 3D printing. Phys Med Biol 2019; 64:215005. [PMID: 31469105 DOI: 10.1088/1361-6560/ab3f6a] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
The aim of this work was to develop a production process for breast phantoms for 2D digital mammography (DM) with realistic anatomical structures and attenuation characteristics based on clinical images using 3D printing. The presented production process is based on PolyJet 3D printing technology using a polypropylene like printing material. First, an attenuation calibration function for this material and the achievable lateral resolution of the printing process of about 200 µm was determined. Subsequently, to generate the digital 3D model of the breast phantom, the pixel intensities of the unprocessed clinical image that are related to the attenuation along the z-axis of the breast, were converted to corresponding phantom heights using the calibration function. To validate the process, an image of the 3D printed breast phantom was acquired on the full field digital mammography (FFDM) system used for calibration and compared with the clinical image in terms of anatomical structures and associated attenuation characteristics. The exposure parameters and image impression of the phantom were evaluated using five other FFDM systems of different manufacturers and types. Results demonstrated that the anatomical structures in the images and the attenuation characteristics of a female breast and the derived phantom agreed on the FFDM system used for calibration. The automatic exposure control segmentation, the automatically selected exposure parameters and the image postprocessing of the clinical and phantom image indicated a high level of conformity. As shown, the phantom is also suitable for other FFDM systems. In conclusion, an approach to produce anthropomorphic breast phantoms for DM offering realistic anatomical structures and attenuation characteristics based on clinical images was successfully developed. As shown, the phantom realistically simulated the original female breast. Therefore, it is expected that such phantoms are promising to support bridging the gap between physical-technical and diagnostic image quality assessment. In addition, they enable a variety of practical and scientific applications for which present technical phantoms are not suitable.
Collapse
Affiliation(s)
- Stephan Schopphoven
- Referenzzentrum Mammographie Süd West, Reference Centre for Mammography Screening Southwest Germany, Bahnhofstrasse 7, 35037 Marburg, Germany. Author to whom any correspondence should be addressed
| | | | | | | | | |
Collapse
|
32
|
Makeev A, Ikejimba LC, Salad J, Glick SJ. Objective assessment of task performance: a comparison of two FFDM detectors using an anthropomorphic breast phantom. J Med Imaging (Bellingham) 2019; 6:043503. [PMID: 31646153 DOI: 10.1117/1.jmi.6.4.043503] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 09/16/2019] [Indexed: 12/20/2022] Open
Abstract
Current digital mammography systems primarily employ one of two types of detectors: indirect conversion, typically using a cesium-iodine scintillator integrated with an amorphous silicon photodiode matrix, or direct conversion, using a photoconductive layer of amorphous selenium (a-Se) combined with thin-film transistor array. The goal of this study was to evaluate a methodology for objectively assessing image quality to compare human observer task performance in detecting microcalcification clusters and extended mass-like lesions achieved with different detector types. The proposed assessment methodology uses a novel anthropomorphic breast phantom fabricated with ink-jet printing. In addition to human observer detection performance, standard linear metrics such as modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE) were also measured to assess image quality. An Analogic Anrad AXS-2430 a-Se detector used in a commercial FFDM/DBT system and a Teledyne Dalsa Xineos-2329 with CMOS pixel readout were evaluated and compared. The DQE of each detector was similar over a range of exposures. Similar task performance in detecting microcalcifications and masses was observed between the two detectors over a range of clinically applicable dose levels, with some perplexing differences in the detection of microcalcifications at the lowest dose measurement. The evaluation approach presented seems promising as a new technique for objective assessment of breast imaging technology.
Collapse
Affiliation(s)
- Andrey Makeev
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Lynda C Ikejimba
- Food and Drug Administration, Silver Spring, Maryland, United States
| | - Jesse Salad
- George Washington University, Washington DC, United States
| | - Stephen J Glick
- Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
33
|
Ikejimba LC, Salad J, Graff CG, Ghammraoui B, Cheng W, Lo JY, Glick SJ. A four‐alternative forced choice (4AFC) methodology for evaluating microcalcification detection in clinical full‐field digital mammography (FFDM) and digital breast tomosynthesis (DBT) systems using an inkjet‐printed anthropomorphic phantom. Med Phys 2019; 46:3883-3892. [DOI: 10.1002/mp.13629] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 04/12/2019] [Accepted: 04/26/2019] [Indexed: 01/14/2023] Open
Affiliation(s)
- Lynda C. Ikejimba
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| | - Jesse Salad
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| | - Christian G. Graff
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| | - Bahaa Ghammraoui
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| | - Wei‐Chung Cheng
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| | - Joseph Y. Lo
- Medical Physics Graduate Program Duke University 2424 Erwin Road Durham NC 27705USA
| | - Stephen J. Glick
- US Food and Drug Administration 10903 New Hampshire Ave Silver Spring MD 20993USA
| |
Collapse
|
34
|
Rossman AH, Catenacci M, Zhao C, Sikaria D, Knudsen JE, Dawes D, Gehm ME, Samei E, Wiley BJ, Lo JY. Three-dimensionally-printed anthropomorphic physical phantom for mammography and digital breast tomosynthesis with custom materials, lesions, and uniform quality control region. J Med Imaging (Bellingham) 2019; 6:021604. [PMID: 30915385 PMCID: PMC6428804 DOI: 10.1117/1.jmi.6.2.021604] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Accepted: 03/01/2019] [Indexed: 11/14/2022] Open
Abstract
Anthropomorphic breast phantoms mimic patient anatomy in order to evaluate clinical mammography and digital breast tomosynthesis system performance. Our goal is to create a modular phantom with an anthropomorphic region to allow for improved lesion and calcification detection as well as a uniform region to evaluate standard quality control (QC) metrics. Previous versions of this phantom used commercial photopolymer inkjet three-dimensional printers to recreate breast anatomy using four surfaces that were fabricated with commercial materials spanning only a limited breast density range of 36% to 64%. We use modified printers to create voxelized, dithered breast phantoms with continuous gradations between glandular and adipose tissues. Moreover, the new phantom replicates the low-end density (representing adipose tissue) using third party material, Jf Flexible, and increases the high-end density to the density of glandular tissue and beyond by either doping Jf Flexible with salts and nanoparticles or using a new commercial resin, VeroPureWhite. An insert design is utilized to add masses, calcifications, and iodinated objects into the phantom for increased utility. The uniform chest wall region provides a space for traditional QC objects such as line pair patterns for measuring resolution and scale bars for measuring printer linearity. Incorporating these distinct design modules enables us to create an improved, complete breast phantom to better evaluate clinical mammography systems for lesion and calcification detection and standard QC performance evaluation.
Collapse
Affiliation(s)
- Andrea H Rossman
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States
| | - Matthew Catenacci
- Duke University, Department of Chemistry, Durham, North Carolina, United States
| | - Christine Zhao
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States.,Duke University, Department of Electrical and Computer Engineering, Durham, North Carolina, United States
| | - Dhiraj Sikaria
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States
| | - John E Knudsen
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States
| | - Danielle Dawes
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States
| | - Michael E Gehm
- Duke University, Department of Electrical and Computer Engineering, Durham, North Carolina, United States
| | - Ehsan Samei
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States.,Duke University, Department of Electrical and Computer Engineering, Durham, North Carolina, United States
| | - Benjamin J Wiley
- Duke University, Department of Chemistry, Durham, North Carolina, United States
| | - Joseph Y Lo
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States.,Duke University School of Medicine, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Durham, North Carolina, United States.,Duke University, Department of Electrical and Computer Engineering, Durham, North Carolina, United States
| |
Collapse
|
35
|
Gerbl A, Lewin M, Zeiske T, Ziegert M, Schwarz FB, Hamm B, Scheel M, Jahnke P. Characterization of office laser printers for 3-D printing of soft tissue CT phantoms. J Med Imaging (Bellingham) 2019; 6:021602. [PMID: 30820442 DOI: 10.1117/1.jmi.6.2.021602] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 12/27/2018] [Indexed: 11/14/2022] Open
Abstract
The purpose of our study is to develop and evaluate a method for radiopaque 3-D printing (R3P) of soft tissue computed tomography (CT) phantoms with office laser printers. Five laser printers from different vendors are tested for toner CT attenuation. A liver phantom is created by printing CT images of a patient liver on office paper. One thousand eight hundred sixty paper sheets are printed with three repeated prints per page, resulting in a stack of 18.6 cm. The phantom is examined with 12 tube current settings. Images are reconstructed using filtered back projection (FBP) and iterative reconstruction [adaptive iterative dose reduction 3D (AIDR 3D)]. Seven radiologists rated image quality of all acquisitions. Toner attenuation of all investigated printers increased linearly with the print template grayscale. The liver phantom reproduced anatomic detail and attenuation values of the patient ( mean ± SD HU difference 12.68 ± 7.74 ). Image quality scores increased with dose but did not vary significantly above a threshold dose for AIDR 3D. Overall, AIDR 3D reconstructed images are rated superior to FBP reconstructions ( p < 0.001 ). In conclusion, R3P with standard office laser printers can generate soft tissue CT phantoms without hardware manipulations but with limited flexibility regarding attenuation properties of the printed toner material.
Collapse
Affiliation(s)
- Andreas Gerbl
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | - Marcel Lewin
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | - Tim Zeiske
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | - Marco Ziegert
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | | | - Bernd Hamm
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | - Michael Scheel
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| | - Paul Jahnke
- Charité-Universitätsmedizin Berlin, Department of Radiology, Berlin, Germany
| |
Collapse
|
36
|
Balta C, Bouwman RW, Sechopoulos I, Broeders MJM, Karssemeijer N, van Engen RE, Veldkamp WJH. Can a channelized Hotelling observer assess image quality in acquired mammographic images of an anthropomorphic breast phantom including image processing? Med Phys 2018; 46:714-725. [PMID: 30561108 DOI: 10.1002/mp.13342] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2018] [Revised: 11/20/2018] [Accepted: 11/30/2018] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To study the feasibility of a channelized Hotelling observer (CHO) to predict human observer performance in detecting calcification-like signals in mammography images of an anthropomorphic breast phantom, as part of a quality control (QC) framework. METHODS A prototype anthropomorphic breast phantom with inserted gold disks of 0.25 mm diameter was imaged with two different digital mammography x-ray systems at four different dose levels. Regions of interest (ROIs) were extracted from the acquired processed and unprocessed images, signal-present and signal-absent. The ROIs were evaluated by a CHO using four different formulations of the difference of Gaussian (DoG) channel sets. Three human observers scored the ROIs in a two-alternative forced-choice experiment. We compared the human and the CHO performance on the simple task to detect calcification-like disks in ROIs with and without postprocessing. The proportion of correct responses of the human reader (PCH ) and the CHO (PCCHO ) was calculated and the correlation between the two was analyzed using a mixed-effect regression model. To address the signal location uncertainty, the impact of shifting the DoG channel sets in all directions up to two pixels was evaluated. Correlation results including the goodness of fit (r2 ) of PCH and PCCHO for all different parameters were evaluated. RESULTS Subanalysis by system yielded strong correlations between PCH and PCCHO , with r2 between PCH and PCCHO was found to be between 0.926 and 0.958 for the unshifted and between 0.759 and 0.938 for the shifted channel sets, respectively. However, the linear fit suggested a slight system dependence. PCCHO with shifted channel sets increased CHO performance but the correlation with humans was decreased. These correlations were not considerably affected by of the DoG channel set used. CONCLUSIONS There is potential for the CHO to be used in QC for the evaluation of detectability of calcification-like signals. The CHO can predict the PC of humans in images of calcification-like signals of two different systems. However, a global model to be used for all systems requires further investigation.
Collapse
Affiliation(s)
- C Balta
- Dutch Expert Centre for Screening (LRCB), Radboud University Medical Center, Wijchenseweg 101, 6538 SW, Nijmegen, The Netherlands.,Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - R W Bouwman
- Dutch Expert Centre for Screening (LRCB), Radboud University Medical Center, Wijchenseweg 101, 6538 SW, Nijmegen, The Netherlands
| | - I Sechopoulos
- Dutch Expert Centre for Screening (LRCB), Radboud University Medical Center, Wijchenseweg 101, 6538 SW, Nijmegen, The Netherlands.,Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - M J M Broeders
- Dutch Expert Centre for Screening (LRCB), Radboud University Medical Center, Wijchenseweg 101, 6538 SW, Nijmegen, The Netherlands.,Department for Health Evidence, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - N Karssemeijer
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, PO Box 9101, 6500 HB, Nijmegen, The Netherlands
| | - R E van Engen
- Dutch Expert Centre for Screening (LRCB), Radboud University Medical Center, Wijchenseweg 101, 6538 SW, Nijmegen, The Netherlands
| | - W J H Veldkamp
- Department of Radiology, Leiden University Medical Centre, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| |
Collapse
|
37
|
Ivanov D, Bliznakova K, Buliev I, Popov P, Mettivier G, Russo P, Di Lillo F, Sarno A, Vignero J, Bosmans H, Bravin A, Bliznakov Z. Suitability of low density materials for 3D printing of physical breast phantoms. ACTA ACUST UNITED AC 2018; 63:175020. [DOI: 10.1088/1361-6560/aad315] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
38
|
Glick SJ, Ikejimba LC. Advances in digital and physical anthropomorphic breast phantoms for x-ray imaging. Med Phys 2018; 45:e870-e885. [DOI: 10.1002/mp.13110] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2017] [Revised: 06/05/2018] [Accepted: 06/10/2018] [Indexed: 01/27/2023] Open
Affiliation(s)
- Stephen J. Glick
- Division of Imaging, Diagnostics, and Software Reliability; Office of Science and Engineering Laboratories; Center for Devices and Radiological Health, Food and Drug Administration; Silver Spring MD 20993 USA
| | - Lynda C. Ikejimba
- Division of Imaging, Diagnostics, and Software Reliability; Office of Science and Engineering Laboratories; Center for Devices and Radiological Health, Food and Drug Administration; Silver Spring MD 20993 USA
| |
Collapse
|
39
|
Paper-based 3D printing of anthropomorphic CT phantoms: Feasibility of two construction techniques. Eur Radiol 2018; 29:1384-1390. [PMID: 30116957 DOI: 10.1007/s00330-018-5654-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Revised: 06/27/2018] [Accepted: 07/04/2018] [Indexed: 12/13/2022]
Abstract
OBJECTIVES To develop and evaluate methods for assembling radiopaque printed paper sheets to realistic patient phantoms for CT dose and image quality testing. METHODS CT images of two patients were radiopaque printed with aqueous potassium iodide solution (0.6 g/ml) on paper. Two methods were developed for assembling the paper sheets to head and neck phantoms. (1) Printed sheets were fed to a paper-based 3D printer along with corresponding 3D printable STL files. (2) Paper stacks of 5-mm thickness were glued with toner, cut to the patient shape and assembled to a phantom. In a sample application study, both phantoms were examined with five different tube current settings. Images were reconstructed using filtered-back projection (FBP) and iterative reconstruction (AIDR 3D) with three strength levels. Dose length product (DLP), signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNRs) were analysed. Data were analysed using 2-way analysis of variance (ANOVA). RESULTS Both methods achieved anthropomorphic phantoms with detailed patient anatomy. The 3D printer yielded a precise reproduction of the external patient shape, but caused visible glue artefacts. Gluing with toner avoided these artefacts and yielded more flexibility with regard to phantom size. In the sample application study, non-inferior SNR and CNR and up to 83.7% lower DLP were achieved on the phantoms with AIDR 3D compared with FBP. CONCLUSIONS Two methods for assembling radiopaque printed paper sheets to phantoms of individual patients are presented. The sample application demonstrates potential for simulation of patient imaging and systematic CT dose and image quality assessment. KEY POINTS • Two methods were developed to create realistic CT phantoms of individual patients from radiopaque printed paper sheets. • Analysis of five tube current and four reconstruction settings on two radiopaque 3D printed patient phantoms yielded non-inferior SNR and CNR and up to 83.7% lower dose with iterative reconstruction in comparison with filtered back projection. • Radiopaque 3D printed phantoms can simulate patients and allow systematic analysis of CT dose and image quality parameters.
Collapse
|
40
|
Balta C, Bouwman RW, Veldkamp WJH, Broeders MJM, Sechopoulos I, van Engen RE. Signal template generation from acquired images for model observer-based image quality analysis in mammography. J Med Imaging (Bellingham) 2018; 5:035503. [PMID: 30840714 PMCID: PMC6129177 DOI: 10.1117/1.jmi.5.3.035503] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 08/13/2018] [Indexed: 09/29/2023] Open
Abstract
Mammography images undergo vendor-specific processing, which may be nonlinear, before radiologist interpretation. Therefore, to test the entire imaging chain, the effect of image processing should be included in the assessment of image quality, which is not current practice. For this purpose, model observers (MOs), in combination with anthropomorphic breast phantoms, are proposed to evaluate image quality in mammography. In this study, the nonprewhitening MO with eye filter and the channelized Hotelling observer were investigated. The goal of this study was to optimize the efficiency of the procedure to obtain the expected signal template from acquired images for the detection of a 0.25-mm diameter disk. Two approaches were followed: using acquired images with homogeneous backgrounds (approach 1) and images from an anthropomorphic breast phantom (approach 2). For quality control purposes, a straightforward procedure using a single exposure of a single disk was found adequate for both approaches. However, only approach 2 can yield templates from processed images since, due to its nonlinearity, image postprocessing cannot be evaluated using images of homogeneous phantoms. Based on the results of the current study, a phantom should be designed, which can be used for the objective assessment of image quality.
Collapse
Affiliation(s)
- Christiana Balta
- Radboud University Medical Center, Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
- Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen, The Netherlands
| | - Ramona W. Bouwman
- Radboud University Medical Center, Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
| | | | - Mireille J. M. Broeders
- Radboud University Medical Center, Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
- Radboud University Medical Center, Radboud Institute for Health Sciences (RIHS), Nijmegen, The Netherlands
| | - Ioannis Sechopoulos
- Radboud University Medical Center, Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
- Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen, The Netherlands
| | - Ruben E. van Engen
- Radboud University Medical Center, Dutch Expert Centre for Screening (LRCB), Nijmegen, The Netherlands
| |
Collapse
|
41
|
Dahal E, Badal A, Zidan A, Alayoubi A, Hagio T, Glick S, Badano A, Ghammraoui B. Stable gelatin-based phantom materials with tunable x-ray attenuation properties and 3D printability for x-ray imaging. ACTA ACUST UNITED AC 2018; 63:09NT01. [DOI: 10.1088/1361-6560/aabd1f] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
42
|
Roumeliotis M, Quirk S, Skarsgard M, Trumpour T, Watt E, Meyer T. Development and characterization of an anthropomorphic breast phantom for permanent breast seed implant brachytherapy credentialing. Brachytherapy 2017; 17:506-513. [PMID: 29241704 DOI: 10.1016/j.brachy.2017.11.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 11/14/2017] [Accepted: 11/15/2017] [Indexed: 11/15/2022]
Abstract
PURPOSE To develop an anthropomorphic breast phantom for use in credentialing of permanent breast seed implant brachytherapy. METHODS AND MATERIALS A representative external contour and target volume was used as the basis of mold manufacturing for anthropomorphic breast phantom development. Both target and normal tissue were composed of gel-like materials that provide suitable computed tomography and ultrasound contrast for brachytherapy delivery. The phantoms were evaluated for consistency in construction (target location) and Hounsfield unit (computed tomography contrast). For both target and normal tissue, the speed of sound was measured and compared to the image reconstruction algorithm's expectation value. Five phantoms were imaged preimplant and postimplant to assess interphantom similarity as well as to evaluate the uncertainty in quantifying seed position. RESULTS The average Hounsfield units of the target and normal tissue gels is -146 ± 5 and 23 ± 1, respectively. The average speed of sound of the target and normal tissue gels is 1485 ± 7 m/s and 1558 ± 9 m/s, respectively, resulting in an estimated 0.4 mm uncertainty in image guidance. The registration/deformation uncertainty was determined to be 0.8 mm. The standard combined uncertainty in assessing seed position spatial accuracy, also including a 0.9 mm estimate based on literature for seed localization, is estimated to be 1.3 mm. CONCLUSIONS The development of the anthropomorphic breast phantom and evaluation of both the consistency as well as overall seed position uncertainty illustrates the suitability of this phantom for use in brachytherapy end-to-end delivery and implant accuracy evaluation. When evaluating a user's implant accuracy, we estimate a standard combined uncertainty of 1.3 mm.
Collapse
Affiliation(s)
- Michael Roumeliotis
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada; Department of Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada.
| | - Sarah Quirk
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada; Department of Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada
| | - Matthew Skarsgard
- Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada
| | - Tiana Trumpour
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada
| | - Elizabeth Watt
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada
| | - Tyler Meyer
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada; Department of Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada
| |
Collapse
|
43
|
Shepard L, Sommer K, Izzo R, Podgorsak A, Wilson M, Said Z, Rybicki FJ, Mitsouras D, Rudin S, Angel E, Ionita CN. Initial Simulated FFR Investigation Using Flow Measurements in Patient-specific 3D Printed Coronary Phantoms. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2017. [PMID: 28649159 DOI: 10.1117/12.2253889] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE Accurate patient-specific phantoms for device testing or endovascular treatment planning can be 3D printed. We expand the applicability of this approach for cardiovascular disease, in particular, for CT-geometry derived benchtop measurements of Fractional Flow Reserve, the reference standard for determination of significant individual coronary artery atherosclerotic lesions. MATERIALS AND METHODS Coronary CT Angiography (CTA) images during a single heartbeat were acquired with a 320×0.5mm detector row scanner (Toshiba Aquilion ONE). These coronary CTA images were used to create 4 patient-specific cardiovascular models with various grades of stenosis: severe, <75% (n=1); moderate, 50-70% (n=1); and mild, <50% (n=2). DICOM volumetric images were segmented using a 3D workstation (Vitrea, Vital Images); the output was used to generate STL files (using AutoDesk Meshmixer), and further processed to create 3D printable geometries for flow experiments. Multi-material printed models (Stratasys Connex3) were connected to a programmable pulsatile pump, and the pressure was measured proximal and distal to the stenosis using pressure transducers. Compliance chambers were used before and after the model to modulate the pressure wave. A flow sensor was used to ensure flow rates within physiological reported values. RESULTS 3D model based FFR measurements correlated well with stenosis severity. FFR measurements for each stenosis grade were: 0.8 severe, 0.7 moderate and 0.88 mild. CONCLUSIONS 3D printed models of patient-specific coronary arteries allows for accurate benchtop diagnosis of FFR. This approach can be used as a future diagnostic tool or for testing CT image-based FFR methods.
Collapse
Affiliation(s)
- Lauren Shepard
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY
| | - Kelsey Sommer
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY
| | - Richard Izzo
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY.,The Jacobs Institute, Buffalo, NY
| | - Alexander Podgorsak
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY
| | - Michael Wilson
- Interventional Cardiology, University at Buffalo Medicine, UBMD, Buffalo, NY
| | - Zaid Said
- Interventional Cardiology, University at Buffalo Medicine, UBMD, Buffalo, NY
| | - Frank J Rybicki
- The Ottawa Hospital Research Institute and the Department of Radiology, University of Ottawa, Ottawa, ON, CA
| | | | - Stephen Rudin
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY
| | - Erin Angel
- Toshiba American Medical Systems, Tustin, CA
| | - Ciprian N Ionita
- University Dept. of Biomedical Engineering, University at Buffalo, Buffalo, NY.,Toshiba Stroke and Vascular Research Center, Buffalo, NY
| |
Collapse
|