1
|
Su SP, Yang YZ, Chiang HK. Development of an integrated dual-modality 3D bioluminescence tomography and ultrasound imaging system for small animal tumor imaging. OPTICS EXPRESS 2024; 32:5607-5620. [PMID: 38439282 DOI: 10.1364/oe.507659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 01/16/2024] [Indexed: 03/06/2024]
Abstract
Ultrasound (US) is a valuable tool for imaging soft tissue and visualizing tumor contours. Taking the benefits of US, we presented an integrated dual-modality imaging system in this paper that achieves three-dimensional (3D) bioluminescence tomography (BLT) with multi-view bioluminescence images and 3D US imaging. The purpose of this system is to perform non-invasive, long-term monitoring of tumor growth in 3D images. US images can enhance the accuracy of the 3D BLT reconstruction and the bioluminescence dose within an object. Furthermore, an integrated co-registered scanning geometry was used to capture the fused BLT and US images. We validated the system with an in vivo experiment involving tumor-bearing mice. The results demonstrated the feasibility of reconstructing 3D BLT images in the tumor region using 3D US images. We used the dice coefficient and locational error to evaluate the similarity between the reconstructed source region and the actual source region. The dice coefficient was 88.5%, and the locational error was 0.4 mm when comparing the BLT and 3D US images. The hybrid BLT/US system could provide significant benefits for reconstructing the source of tumor location and conducting quantitative analysis of tumor size.
Collapse
|
2
|
Xu X, Deng Z, Sforza D, Tong Z, Tseng YP, Newman C, Reinhart M, Tsouchlos P, Devling T, Dehghani H, Iordachita I, Wong JW, Wang KKH. Characterization of a commercial bioluminescence tomography-guided system for pre-clinical radiation research. Med Phys 2023; 50:6433-6453. [PMID: 37633836 PMCID: PMC10592094 DOI: 10.1002/mp.16669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 06/06/2023] [Accepted: 07/18/2023] [Indexed: 08/28/2023] Open
Abstract
BACKGROUND Widely used Cone-beam computed tomography (CBCT)-guided irradiators have limitations in localizing soft tissue targets growing in a low-contrast environment. This hinders small animal irradiators achieving precise focal irradiation. PURPOSE To advance image-guidance for soft tissue targeting, we developed a commercial-grade bioluminescence tomography-guided system (BLT, MuriGlo) for pre-clinical radiation research. We characterized the system performance and demonstrated its capability in target localization. We expect this study can provide a comprehensive guideline for the community in utilizing the BLT system for radiation studies. METHODS MuriGlo consists of four mirrors, filters, lens, and charge-coupled device (CCD) camera, enabling a compact imaging platform and multi-projection and multi-spectral BLT. A newly developed mouse bed allows animals imaged in MuriGlo and transferred to a small animal radiation research platform (SARRP) for CBCT imaging and BLT-guided irradiation. Methods and tools were developed to evaluate the CCD response linearity, minimal detectable signal, focusing, spatial resolution, distortion, and uniformity. A transparent polycarbonate plate covering the middle of the mouse bed was used to support and image animals from underneath the bed. We investigated its effect on 2D Bioluminescence images and 3D BLT reconstruction accuracy, and studied its dosimetric impact along with the rest of mouse bed. A method based on pinhole camera model was developed to map multi-projection bioluminescence images to the object surface generated from CBCT image. The mapped bioluminescence images were used as the input data for the optical reconstruction. To account for free space light propagation from object surface to optical detector, a spectral derivative (SD) method was implemented for BLT reconstruction. We assessed the use of the SD data (ratio imaging of adjacent wavelength) in mitigating out of focusing and non-uniformity seen in the images. A mouse phantom was used to validate the data mapping. The phantom and an in vivo glioblastoma model were utilized to demonstrate the accuracy of the BLT target localization. RESULTS The CCD response shows good linearity with < 0.6% residual from a linear fit. The minimal detectable level is 972 counts for 10 × 10 binning. The focal plane position is within the range of 13-18 mm above the mouse bed. The spatial resolution of 2D optical imaging is < 0.3 mm at Rayleigh criterion. Within the region of interest, the image uniformity is within 5% variation, and image shift due to distortion is within 0.3 mm. The transparent plate caused < 6% light attenuation. The use of the SD imaging data can effectively mitigate out of focusing, image non-uniformity, and the plate attenuation, to support accurate multi-spectral BLT reconstruction. There is < 0.5% attenuation on dose delivery caused by the bed. The accuracy of data mapping from the 2D bioluminescence images to CBCT image is within 0.7 mm. Our phantom test shows the BLT system can localize a bioluminescent target within 1 mm with an optimal threshold and only 0.2 mm deviation was observed for the case with and without a transparent plate. The same localization accuracy can be maintained for the in vivo GBM model. CONCLUSIONS This work is the first systematic study in characterizing the commercial BLT-guided system. The information and methods developed will be useful for the community to utilize the imaging system for image-guided radiation research.
Collapse
Affiliation(s)
- Xiangkun Xu
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Zijian Deng
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Daniel Sforza
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA
| | - Zhishen Tong
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Yu-Pei Tseng
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Ciara Newman
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | | | | | | | - Hamid Dehghani
- School of Computer Science, University of Birmingham, Birmingham, B15 2TT, UK
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA
| | - John W. Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland, USA
| | - Ken Kang-Hsin Wang
- Biomedical Imaging and Radiation Technology Laboratory (BIRTLab), Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
3
|
Chen J, Zhao N, Copello V, Ru Y, Burnstein KL, Yang Y. Accurate and Early Metastases Diagnosis in Live Animals With Multimodal X-ray and Optical Imaging. Int J Radiat Oncol Biol Phys 2023; 115:511-517. [PMID: 35931351 DOI: 10.1016/j.ijrobp.2022.07.1832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 07/02/2022] [Accepted: 07/23/2022] [Indexed: 01/11/2023]
Abstract
PURPOSE In vivo optical imaging systems are essential to track disease progression and evaluate therapeutic efficacy in animal studies. However, current approaches are limited by their inability to accurately capture 3-dimensional (3-D) image information. To overcome this hindrance, we adopted x-ray computed tomography (CT) as a prior for 3-D optical image reconstruction and further challenged the multimodal imaging performance with a metastasis model. METHODS AND MATERIALS The iSMAART system, an integrated small animal research platform, features coregistered high-quality quantitative optical tomography and CT. In the synergistic dual-modality imaging, CT provides both 3-D anatomy information and animal structure mesh for optical tomography reconstruction, which is performed using bioluminescence projections acquired from 4 orthogonal angles. The multimodal imaging system was challenged with a prostate cancer metastasis model, and a double-blind histopathology diagnosis was obtained to validate the imaging results. RESULTS The iSMAART located, visualized, and quantified early tumor metastases at the millimeter scale, and can accurately track deep tumors as small as 1.5 mm in live animals. Tumors metastasized into the liver, diaphragm, and tibia in 4 mice were all successfully diagnosed by the integrated tomographic imaging. CONCLUSIONS Instead of roughly comparing surface-light intensities, as traditionally performed in 2-dimensional optical imaging, iSMAART provides accurate tumor imaging and quantitative assessment capabilities with integrated CT and optical tomography for cancer metastasis research. With the powerful 3-D optical/CT imaging capability, iSMAART has the potential to tackle more complex research needs with higher targeting accuracy.
Collapse
Affiliation(s)
- Jiahao Chen
- Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, China
| | - Ning Zhao
- Department of Engineering and Applied Physics, University of Science and Technology of China, Hefei, China
| | - Valeria Copello
- Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami, Miami, Florida
| | - Yi Ru
- Department of Pathology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou, China
| | - Kerry L Burnstein
- Sylvester Comprehensive Cancer Center, Miller School of Medicine, University of Miami, Miami, Florida; Department of Molecular and Cellular Pharmacology, Miller School of Medicine, University of Miami, Miami, Florida
| | - Yidong Yang
- Department of Radiation Oncology, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China; School of Physical Sciences and Ion Medical Research Institute, University of Science and Technology of China, Hefei, Anhui, China.
| |
Collapse
|
4
|
Mastraccio KE, Huaman C, Laing ED, Broder CC, Schaefer BC. Longitudinal Tracing of Lyssavirus Infection in Mice via In Vivo Bioluminescence Imaging. Methods Mol Biol 2022; 2524:369-394. [PMID: 35821488 DOI: 10.1007/978-1-0716-2453-1_30] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Bioluminescence imaging (BLI) is a technique that can be employed to quantify biological processes in living cells. When used in small animal models such as mice, BLI can provide both longitudinal and positional information regarding the biological process under investigation. Although perhaps best known for its utility in non-invasively quantifying tumor burden over time in experimental animals, BLI has also been applied in many pathogenesis models to track pathogen burden and responses to therapeutic interventions. In this chapter, we present a BLI-based method for tracing anatomical progression of lyssavirus infection in a mouse model. We also include validation methods to ensure that semiquantitative BLI data correlate well with viral load. Due to the longitudinal nature of this approach, lyssavirus pathogenesis and therapeutic intervention studies can be performed with far fewer animals than more traditional approaches, which typically require euthanasia of large animal groups at every data collection time point.
Collapse
Affiliation(s)
- Kate E Mastraccio
- Department of Microbiology and Immunology, Uniformed Services University, Bethesda, MD, USA
- David Axelrod Institute, Wadsworth Center, NYS Department of Health, Albany, NY, USA
| | - Celeste Huaman
- Department of Microbiology and Immunology, Uniformed Services University, Bethesda, MD, USA
| | - Eric D Laing
- Department of Microbiology and Immunology, Uniformed Services University, Bethesda, MD, USA
| | - Christopher C Broder
- Department of Microbiology and Immunology, Uniformed Services University, Bethesda, MD, USA
| | - Brian C Schaefer
- Department of Microbiology and Immunology, Uniformed Services University, Bethesda, MD, USA.
| |
Collapse
|
5
|
Xu X, Deng Z, Dehghani H, Iordachita I, Lim M, Wong JW, Wang KKH. Quantitative Bioluminescence Tomography-guided Conformal Irradiation for Preclinical Radiation Research. Int J Radiat Oncol Biol Phys 2021; 111:1310-1321. [PMID: 34411639 PMCID: PMC8602741 DOI: 10.1016/j.ijrobp.2021.08.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 07/16/2021] [Accepted: 08/05/2021] [Indexed: 10/31/2022]
Abstract
PURPOSE Widely used cone beam computed tomography (CBCT)-guided irradiators in preclinical radiation research are limited to localize soft tissue target because of low imaging contrast. Knowledge of target volume is a fundamental need for radiation therapy (RT). Without such information to guide radiation, normal tissue can be overirradiated, introducing experimental uncertainties. This led us to develop high-contrast quantitative bioluminescence tomography (QBLT) for guidance. The use of a 3-dimensional bioluminescence signal, related to cell viability, for preclinical radiation research is one step toward biology-guided RT. METHODS AND MATERIALS Our QBLT system enables multiprojection and multispectral bioluminescence imaging to maximize input data for the tomographic reconstruction. Accurate quantification of spectrum and dynamic change of in vivo signal were also accounted for the QBLT. A spectral-derivative method was implemented to eliminate the modeling of the light propagation from animal surface to detector. We demonstrated the QBLT capability of guiding conformal RT using a bioluminescent glioblastoma (GBM) model in vivo. A threshold was determined to delineate QBLT reconstructed gross target volume (GTVQBLT), which provides the best overlap between the GTVQBLT and CBCT contrast labeled GBM (GTV), used as the ground truth for GBM volume. To account for the uncertainty of GTVQBLT in target positioning and volume delineation, a margin was determined and added to the GTVQBLT to form a QBLT planning target volume (PTVQBLT) for guidance. RESULTS The QBLT can reconstruct in vivo GBM with localization accuracy within 1 mm. A 0.5-mm margin was determined and added to GTVQBLT to form PTVQBLT, largely improving tumor coverage from 75.0% (0 mm margin) to 97.9% in average, while minimizing normal tissue toxicity. With the goal of prescribed dose 5 Gy covering 95% of PTVQBLT, QBLT-guided 7-field conformal RT can effectively irradiate 99.4 ± 1.0% of GTV. CONCLUSIONS The QBLT provides a unique opportunity for investigators to use biologic information for target delineation, guiding conformal irradiation, and reducing normal tissue involvement, which is expected to increase reproducibility of scientific discovery.
Collapse
Affiliation(s)
- Xiangkun Xu
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland; Biomedical Imaging and Radiation Technology Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Zijian Deng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland; Biomedical Imaging and Radiation Technology Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Hamid Dehghani
- School of Computer Science, University of Birmingham, Birmingham, West Midlands, United Kingdom
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland
| | - Michael Lim
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland; Department of Neurosurgery, Stanford University, Stanford, California
| | - John W Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland; Biomedical Imaging and Radiation Technology Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas.
| |
Collapse
|
6
|
Ahmad A, Shi J, Ansari S, Afaghani J, Molina J, Pollack A, Merscher S, Zeidan YH, Fornoni A, Marples B. Noninvasive assessment of radiation-induced renal injury in mice. Int J Radiat Biol 2021; 97:664-674. [PMID: 33464992 DOI: 10.1080/09553002.2021.1876950] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE The kidney is a radiosensitive late-responding normal tissue. Injury is characterized by radiation nephropathy and decline of glomerular filtration rate (GFR). The current study aimed to compare two rapid and cost-effective methodologies of assessing GFR against more conventional biomarker measurements. METHODS C57BL/6 mice were treated with bilateral focal X-irradiation (1x14Gy or 5x6Gy). Functional measurements of kidney injury were assessed 20 weeks post-treatment. GFR was estimated using a transcutaneous measurement of fluorescein-isothiocyanate conjugated (FITC)-sinistrin renal excretion and also dynamic contrast-enhanced CT imaging with a contrast agent (ISOVUE-300 Iopamidol). RESULTS Hematoxylin and eosin (H&E) and Periodic acid-Schiff staining identified comparable radiation-induced glomerular atrophy and mesangial matrix accumulation after both radiation schedules, respectively, although the fractionated regimen resulted in less diffuse tubulointerstitial fibrosis. Albumin-to-creatinine ratios (ACR) increased after irradiation (1x14Gy: 100.4 ± 12.2 µg/mg; 6x5Gy: 80.4 ± 3.02 µg/mg) and were double that of nontreated controls (44.9 ± 3.64 µg/mg). GFR defined by both techniques was negatively correlated with BUN, mesangial expansion score, and serum creatinine. The FITC-sinistrin transcutaneous method was more rapid and can be used to assess GFR in conscious animals, dynamic contrast-enhanced CT imaging technique was equally safe and effective. CONCLUSION This study demonstrated that GFR measured by dynamic contrast-enhanced CT imaging is safe and effective compared to transcutaneous methodology to estimate kidney function.
Collapse
Affiliation(s)
- Anis Ahmad
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Junwei Shi
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Saba Ansari
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Jumana Afaghani
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Judith Molina
- Katz Family Division of Nephrology and Hypertension, Department of Medicine, Peggy and Harold Katz Family Drug Discovery Center, University of Miami, Miami, FL, USA
| | - Alan Pollack
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA
| | - Sandra Merscher
- Katz Family Division of Nephrology and Hypertension, Department of Medicine, Peggy and Harold Katz Family Drug Discovery Center, University of Miami, Miami, FL, USA
| | - Youssef H Zeidan
- Department of Radiation Oncology, Anatomy, Cell Biology, and Physiology, American University of Beirut School of Medicine, Beirut, Lebanon
| | - Alessia Fornoni
- Katz Family Division of Nephrology and Hypertension, Department of Medicine, Peggy and Harold Katz Family Drug Discovery Center, University of Miami, Miami, FL, USA
| | - Brian Marples
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Sylvester Comprehensive Cancer Center, Miami, FL, USA.,Katz Family Division of Nephrology and Hypertension, Department of Medicine, Peggy and Harold Katz Family Drug Discovery Center, University of Miami, Miami, FL, USA.,Department of Radiation Oncology, University of Rochester, Rochester, NY, USA
| |
Collapse
|
7
|
Alsawaftah N, Farooq A, Dhou S, Majdalawieh AF. Bioluminescence Imaging Applications in Cancer: A Comprehensive Review. IEEE Rev Biomed Eng 2021; 14:307-326. [PMID: 32746363 DOI: 10.1109/rbme.2020.2995124] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
Bioluminescence imaging (BLI), an optical preclinical imaging modality, is an invaluable imaging modality due to its low-cost, high throughput, fast acquisition times, and functional imaging capabilities. BLI is being extensively used in the field of cancer imaging, especially with the recent developments in genetic-engineering, stem cell, and gene therapy treatments. The purpose of this paper is to provide a comprehensive review of the principles, developments, and current status of BLI in cancer research. This paper covers the fundamental BLI concepts including BLI reporters and enzyme-substrate systems, data acquisition, and image characteristics. It reviews the studies discussing the use of BLI in cancer research such as imaging tumor-characteristic phenomena including tumorigenesis, metastasis, cancer metabolism, apoptosis, hypoxia, and angiogenesis, and response to cancer therapy treatments including chemotherapy, radiotherapy, immunotherapy, gene therapy, and stem cell therapy. The key advantages and disadvantages of BLI compared to other common imaging modalities are also discussed.
Collapse
|
8
|
Deng Z, Xu X, Dehghani H, Reyes J, Zheng L, Klose AD, Wong JW, Tran PT, Wang KKH. In vivo bioluminescence tomography-guided radiation research platform for pancreatic cancer: an initial study using subcutaneous and orthotopic pancreatic tumor models. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2020; 11224. [PMID: 33223595 DOI: 10.1117/12.2546503] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Genetically engineered mouse model(GEMM) that develops pancreatic ductal adenocarcinoma(PDAC) offers an experimental system to advance our understanding of radiotherapy(RT) for pancreatic cancer. Cone beam CT(CBCT)-guided small animal radiation research platform(SARRP) has been developed to mimic the RT used for human. However, we recognized that CBCT is inadequate to localize the PDAC growing in low image contrast environment. We innovated bioluminescence tomography(BLT) to guide SARRP irradiation for in vivo PDAC. Before working on the complex PDAC-GEMM, we first validated our BLT target localization using subcutaneous and orthotopic pancreatic tumor models. Our BLT process involves the animal transport between the BLT system and SARRP. We inserted a titanium wire into the orthotopic tumor as the fiducial marker to track the tumor location and to validate the BLT reconstruction accuracy. Our data shows that with careful animal handling, minimum disturbance for target position was introduced during our BLT imaging procedure(<0.5mm). However, from longitudinal 2D bioluminescence image(BLI) study, the day-to-day location variation for an abdominal tumor can be significant. We also showed that the 2D BLI in single projection setting cannot accurately capture the abdominal tumor location. It renders that 3D BLT with multiple-projection is needed to quantify the tumor volume and location for precise radiation research. Our initial results show the BLT can retrieve the location at 2mm accuracy for both tumor models, and the tumor volume can be delineated within 25% accuracy. The study for the subcutaneous and orthotopic models will provide us valuable knowledge for BLT-guided PDAC-GEMM radiation research.
Collapse
Affiliation(s)
- Zijian Deng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | - Xiangkun Xu
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | - Hamid Dehghani
- School of Computer Science, University of Birmingham, Edgbaston, Birmingham, UK B15 2TT
| | - Juvenal Reyes
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | - Lei Zheng
- Department of Oncology, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287.,Precision Medicine Center of Excellence Program for Pancreatic Cancer, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | | | - John W Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | - Phuoc T Tran
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA 21287
| |
Collapse
|
9
|
Shi J, Xu K, Keyvanloo A, Udayakumar TS, Ahmad A, Yang F, Yang Y. A Multimodality Image Guided Precision Radiation Research Platform: Integrating X-ray, Bioluminescence, and Fluorescence Tomography With Radiation Therapy. Int J Radiat Oncol Biol Phys 2020; 108:1063-1072. [PMID: 32585336 DOI: 10.1016/j.ijrobp.2020.06.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Revised: 05/25/2020] [Accepted: 06/14/2020] [Indexed: 01/17/2023]
Abstract
PURPOSE Small animal irradiation is crucial to the investigation of radiobiological mechanisms. The paradigm of clinical radiation therapy is trending toward high-precision, stereotactic treatment. However, translating this scheme to small animal irradiation is challenging owing to the lack of high-quality image guidance. To overcome this obstacle, we developed a multimodality image guided precision radiation platform. METHODS AND MATERIALS The platform consists of 4 modules: x-ray computed tomography (CT), bioluminescence tomography (BLT), fluorescence molecular tomography (FMT), and radiation therapy. CT provides animal anatomy and material density for radiation dose calculation, as well as body contour for BLT and FMT reconstruction. BLT and FMT provide tumor localization to guide radiation beams and molecular activity to evaluate treatment outcome. Furthermore, we developed a Monte Carlo-based treatment planning system (TPS) for 3-dimensional dose calculation, calibrated it using radiochromic films sandwiched in a water-equivalent phantom, and validated it using in vivo dosimeters surgically implanted into euthanized mice (n = 4). Finally, we performed image guided irradiation on mice bearing orthotopic breast and prostate tumors and confirmed radiation delivery using γH2AX histology. RESULTS The Monte Carlo-based TPS was successfully calibrated by benchmarking simulation dose against film measurement. For in vivo dosimetry measured in the euthanized mice, the average difference between the TPS calculated dose and measured dose was 3.86% ± 1.12%. Following the TPS-generated treatment plan, we successfully delivered 20 Gy dose to an animal bearing an orthotopic prostate tumor using 4 BLT-guided radiation beams and 5 Gy dose to an animal bearing an orthotopic breast tumor using a single FMT-guided radiation beam. γH2AX histology presented significantly more DNA damage in irradiated tumors and thus validated the dose delivery accuracy. CONCLUSIONS Combined with Monte Carlo TPS, this multimodality CT/BLT/FMT image guided small animal radiation platform can specifically localize tumors, accurately calculate dose distribution, precisely guide radiation delivery, and molecularly evaluate treatment response. It provides an advanced toolset for radiobiology and translational cancer research.
Collapse
Affiliation(s)
- Junwei Shi
- University of Miami School of Medicine, Miami, Florida
| | - Keying Xu
- University of Miami School of Medicine, Miami, Florida; University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | | | | | - Anis Ahmad
- University of Miami School of Medicine, Miami, Florida
| | - Fei Yang
- University of Miami School of Medicine, Miami, Florida
| | - Yidong Yang
- University of Miami School of Medicine, Miami, Florida; Department of Radiation Oncology, the First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China; School of Physical Sciences, University of Science and Technology of China, Hefei, China.
| |
Collapse
|
10
|
Wang H, Nie K, Kuang Y. An On-Board Spectral-CT/CBCT/SPECT Imaging Configuration for Small-Animal Radiation Therapy Platform: A Monte Carlo Study. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:588-600. [PMID: 31380751 DOI: 10.1109/tmi.2019.2932333] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This study investigated the feasibility of a highly specific multiplexed image-guided small animal radiation therapy (SART) platform based on triple imaging from on-board single-photon emission computed tomography (SPECT), spectral-CT, and cone-beam CT (CBCT) guidance in radiotherapy treatment. As a proof-of-concept, the SART system was built with the capability of triple on-board image guidance by utilizing an x-ray tube and a single cadmium zinc telluride (CZT) semiconductor photon-counting imager via a Monte Carlo simulation study. The x-ray tube can be set at a low tube current for imaging mode and a high tube current for radiation therapy mode, respectively. In the imaging mode, both x-ray and gamma-ray projection data were collected by the imager to reconstruct CBCT, SPECT and spectral CT images of small animals being treated. The modulation transfer function (MTF) of the pixelated CZT imager measured was 8.6 lp/mm. The overall performances of the CBCT and SPECT imaging of the system were evaluated with sufficient spatial resolution and imaging quality to be fitted into the SART platform. The material differentiation and decomposition capacities of spectral CT within the system were verified using K-edge imaging, image-based optimal energy weighted imaging, and image-based linear material decomposition methods. The triple imaging capability of the system was demonstrated using a PMMA phantom containing gadolinium, iodine and radioisotope 99mTc inserts. All the probes were clearly identified in the registered image. The results demonstrated that a novel SART platform with high-quality on-board CBCT, spectral-CT, SPECT image guidance is technically feasible by using a single semiconductor imager, thus affording comprehensive image guidance from anatomical, functional, and molecular levels for radiation treatment beam delivery.
Collapse
|
11
|
Shi J, Granger B, Xu K, Yang Y. Quantitative X-ray fluorescence imaging of gold nanoparticles using joint L1 and total variation regularized reconstruction. Quant Imaging Med Surg 2020; 10:184-196. [PMID: 31956541 DOI: 10.21037/qims.2019.10.15] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Background This work proposed a joint L1 and total variation (TV) regularized reconstruction method for X-ray fluorescence tomography (XFT), and investigated the performance of this method in quantitative imaging of gold nanoparticles (GNPs). Methods We developed a dual-modality XFT/CT imaging system which consisted of a benchtop X-ray source, a translation/rotation stage, a silicon drift detector for X-ray fluorescence (XRF) detection, and a flat panel detector for transmission X-ray detection. A pencil-beam collimator was 3D printed with steel and employed in sample excitation. The sensitivity of the XFT imaging system was determined by imaging water phantoms with multiple inserts containing GNP solutions of various concentrations (0.02-0.16 wt.%). A joint L1 and total variation (TV) regularized algorithm was developed for XFT reconstruction, where the L1 regularization was used to reduce image artifacts and the TV regularization was used to preserve the shape of targets. Nonlinear conjugate gradient (NCG) descent algorithm with backtracking line search was adopted to solve the reconstruction problem. We compared the L1 + TV regularization method with filtered back projection (FBP), maximum likelihood expectation maximization (ML-EM), L1 regularization, and TV regularization methods. Contrast-to-noise ratio (CNR), Dice similarity coefficient (DSC) and localization error (LE) metrics were used to compare the performance of different methods. The CT and XFT imaging doses were also measured using EBT2 radiochromic films. Results The 3D printed pencil-beam collimator shaped an excitation beam with a 2 mm full width at half maximum at the imaging isocenter. Based on the phantom imaging experiments, the joint L1 and TV regularization method performed better than FBP, ML-EM, L1 regularization and TV regularization methods, with higher localization accuracy (offset <0.6 mm), CNR and DSC values. Compared with CT, XFT with L1 + TV regularized reconstruction demonstrated higher sensitivity in GNP imaging, and could detect GNP at a concentration of 0.02 wt.% or lower. Moreover, there existed a significant linear correlation (R2>0.99) between the reconstructed and true GNP concentration. The estimated XFT imaging dose is about 41.22 cGy under current setting. Conclusions The joint L1 + TV regularized reconstruction algorithm performed better in noise suppression and shape preservation. Using the L1 + TV regularized reconstruction, the XFT system is able to localize GNP targets with submillimeter accuracy and quantify GNP distribution at a concentration of 0.02 wt.% or lower.
Collapse
Affiliation(s)
- Junwei Shi
- The Miller School of Medicine, University of Miami, FL, USA
| | - Blaine Granger
- The Miller School of Medicine, University of Miami, FL, USA
| | - Keying Xu
- The Miller School of Medicine, University of Miami, FL, USA
| | - Yidong Yang
- The Miller School of Medicine, University of Miami, FL, USA.,School of Physical Sciences, University of Science and Technology of China, Hefei 230026, China.,Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei 230001, China
| |
Collapse
|
12
|
Deng Z, Xu X, Garzon-Muvdi T, Xia Y, Kim E, Belcaid Z, Luksik A, Maxwell R, Choi J, Wang H, Yu J, Iordachita I, Lim M, Wong JW, Wang KKH. In Vivo Bioluminescence Tomography Center of Mass-Guided Conformal Irradiation. Int J Radiat Oncol Biol Phys 2019; 106:612-620. [PMID: 31738948 DOI: 10.1016/j.ijrobp.2019.11.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 10/24/2019] [Accepted: 11/03/2019] [Indexed: 01/21/2023]
Abstract
PURPOSE The cone-beam computed tomography (CBCT)-guided small animal radiation research platform (SARRP) has provided unique opportunities to test radiobiologic hypotheses. However, CBCT is less adept to localize soft tissue targets growing in a low imaging contrast environment. Three-dimensional bioluminescence tomography (BLT) provides strong image contrast and thus offers an attractive solution. We introduced a novel and efficient BLT-guided conformal radiation therapy and demonstrated it in an orthotopic glioblastoma (GBM) model. METHODS AND MATERIALS A multispectral BLT system was integrated with SARRP for radiation therapy (RT) guidance. GBM growth curve was first established by contrast CBCT/magnetic resonance imaging (MRI) to derive equivalent sphere as approximated gross target volume (aGTV). For BLT, mice were subject to multispectral bioluminescence imaging, followed by SARRP CBCT imaging and optical reconstruction. The CBCT image was acquired to generate anatomic mesh for the reconstruction and RT planning. To ensure high accuracy of the BLT-reconstructed center of mass (CoM) for target localization, we optimized the optical absorption coefficients μa by minimizing the distance between the CoMs of BLT reconstruction and contrast CBCT/MRI-delineated GBM volume. The aGTV combined with the uncertainties of BLT CoM localization and target volume determination was used to generate estimated target volume (ETV). For conformal irradiation procedure, the GBM was first localized by the predetermined ETV centered at BLT-reconstructed CoM, followed by SARRP radiation. The irradiation accuracy was qualitatively confirmed by pathologic staining. RESULTS Deviation between CoMs of BLT reconstruction and contrast CBCT/MRI-imaged GBM is approximately 1 mm. Our derived ETV centered at BLT-reconstructed CoM covers >95% of the tumor volume. Using the second-week GBM as an example, the ETV-based BLT-guided irradiation can cover 95.4% ± 4.7% tumor volume at prescribed dose. The pathologic staining demonstrated the BLT-guided irradiated area overlapped well with the GBM location. CONCLUSIONS The BLT-guided RT enables 3-dimensional conformal radiation for important orthotopic tumor models, which provides investigators a new preclinical research capability.
Collapse
Affiliation(s)
- Zijian Deng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Xiangkun Xu
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Tomas Garzon-Muvdi
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland; Department of Neurosurgery, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Yuanxuan Xia
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Eileen Kim
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Zineb Belcaid
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Andrew Luksik
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Russell Maxwell
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - John Choi
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Hailun Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Jingjing Yu
- School of Physics and Information Technology, Shaanxi Normal University, Shanxi, China
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland
| | - Michael Lim
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - John W Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland.
| |
Collapse
|
13
|
Verhoeven J, Bolcaen J, De Meulenaere V, Kersemans K, Descamps B, Donche S, Van den Broecke C, Boterberg T, Kalala JP, Deblaere K, Vanhove C, De Vos F, Goethals I. Technical feasibility of [ 18F]FET and [ 18F]FAZA PET guided radiotherapy in a F98 glioblastoma rat model. Radiat Oncol 2019; 14:89. [PMID: 31146757 PMCID: PMC6543630 DOI: 10.1186/s13014-019-1290-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Accepted: 05/08/2019] [Indexed: 12/21/2022] Open
Abstract
Background Glioblastoma (GB) is the most common primary malignant brain tumor. Standard medical treatment consists of a maximal safe surgical resection, subsequently radiation therapy (RT) and chemotherapy with temozolomide (TMZ). An accurate definition of the tumor volume is of utmost importance for guiding RT. In this project we investigated the feasibility and treatment response of subvolume boosting to a PET-defined tumor part. Method F98 GB cells inoculated in the rat brain were imaged using T2- and contrast-enhanced T1-weighted (T1w) MRI. A dose of 20 Gy (5 × 5 mm2) was delivered to the target volume delineated based on T1w MRI for three treatment groups. Two of those treatment groups received an additional radiation boost of 5 Gy (1 × 1 mm2) delivered to the region either with maximum [18F]FET or [18F]FAZA PET tracer uptake, respectively. All therapy groups received intraperitoneal (IP) injections of TMZ. Finally, a control group received no RT and only control IP injections. The average, minimum and maximum dose, as well as the D90-, D50- and D2- values were calculated for nine rats using both RT plans. To evaluate response to therapy, follow-up tumor volumes were delineated based on T1w MRI. Results When comparing the dose volume histograms, a significant difference was found exclusively between the D2-values. A significant difference in tumor growth was only found between active therapy and sham therapy respectively, while no significant differences were found when comparing the three treatment groups. Conclusion In this study we showed the feasibility of PET guided subvolume boosting of F98 glioblastoma in rats. No evidence was found for a beneficial effect regarding tumor response. However, improvements for dose targeting in rodents and studies investigating new targeted drugs for GB treatment are mandatory. Electronic supplementary material The online version of this article (10.1186/s13014-019-1290-4) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
| | - Julie Bolcaen
- Ghent University Hospital, Department of Nuclear Medicine, Ghent, Belgium.,National Research Foundation (NRF), iThemba LABS, Somerset West, South Africa
| | - Valerie De Meulenaere
- Ghent University Hospital, Department of Radiology and Medical Imaging, Ghent, Belgium
| | - Ken Kersemans
- Ghent University Hospital, Department of Nuclear Medicine, Ghent, Belgium
| | - Benedicte Descamps
- IBiTech-MEDISIP Ghent University, Department of Electronics and Information Systems, Ghent, Belgium
| | - Sam Donche
- Ghent University Hospital, Department of Nuclear Medicine, Ghent, Belgium
| | | | - Tom Boterberg
- Ghent University Hospital, Department of Radiation Oncology, Ghent, Belgium
| | | | - Karel Deblaere
- Ghent University Hospital, Department of Radiology and Medical Imaging, Ghent, Belgium
| | - Christian Vanhove
- IBiTech-MEDISIP Ghent University, Department of Electronics and Information Systems, Ghent, Belgium
| | - Filip De Vos
- Laboratory of Radiopharmacy, Ghent University, Ghent, Belgium
| | - Ingeborg Goethals
- Ghent University Hospital, Department of Nuclear Medicine, Ghent, Belgium
| |
Collapse
|
14
|
Evolution of the Supermodel: Progress in Modelling Radiotherapy Response in Mice. Clin Oncol (R Coll Radiol) 2019; 31:272-282. [PMID: 30871751 DOI: 10.1016/j.clon.2019.02.008] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 02/14/2019] [Accepted: 02/15/2019] [Indexed: 12/18/2022]
Abstract
Mouse models are essential tools in cancer research that have been used to understand the genetic basis of tumorigenesis, cancer progression and to test the efficacies of anticancer treatments including radiotherapy. They have played a critical role in our understanding of radiotherapy response in tumours and normal tissues and continue to evolve to better recapitulate the underlying biology of humans. In addition, recent developments in small animal irradiators have significantly improved in vivo irradiation techniques, allowing previously unimaginable experimental approaches to be explored in the laboratory. The combination of contemporary mouse models with small animal irradiators represents a major step forward for the radiobiology field in being able to much more accurately replicate clinical exposure scenarios. As radiobiology studies become ever more sophisticated in reflecting developments in the clinic, it is increasingly important to understand the basis and potential limitations of extrapolating data from mice to humans. This review provides an overview of mouse models and small animal radiotherapy platforms currently being used as advanced radiobiological research tools towards improving the translational power of preclinical studies.
Collapse
|
15
|
Integrating Small Animal Irradiators withFunctional Imaging for Advanced Preclinical Radiotherapy Research. Cancers (Basel) 2019; 11:cancers11020170. [PMID: 30717307 PMCID: PMC6406472 DOI: 10.3390/cancers11020170] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Revised: 01/23/2019] [Accepted: 01/29/2019] [Indexed: 12/16/2022] Open
Abstract
Translational research aims to provide direct support for advancing novel treatment approaches in oncology towards improving patient outcomes. Preclinical studies have a central role in this process and the ability to accurately model biological and physical aspects of the clinical scenario in radiation oncology is critical to translational success. The use of small animal irradiators with disease relevant mouse models and advanced in vivo imaging approaches offers unique possibilities to interrogate the radiotherapy response of tumors and normal tissues with high potential to translate to improvements in clinical outcomes. The present review highlights the current technology and applications of small animal irradiators, and explores how these can be combined with molecular and functional imaging in advanced preclinical radiotherapy research.
Collapse
|
16
|
Donche S, Verhoeven J, Descamps B, Bolcaen J, Deblaere K, Boterberg T, Van den Broecke C, Vanhove C, Goethals I. The Path Toward PET-Guided Radiation Therapy for Glioblastoma in Laboratory Animals: A Mini Review. Front Med (Lausanne) 2019; 6:5. [PMID: 30761302 PMCID: PMC6361864 DOI: 10.3389/fmed.2019.00005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Accepted: 01/10/2019] [Indexed: 12/13/2022] Open
Abstract
Glioblastoma is the most aggressive and malignant primary brain tumor in adults. Despite the current state-of-the-art treatment, which consists of maximal surgical resection followed by radiation therapy, concomitant, and adjuvant chemotherapy, progression remains rapid due to aggressive tumor characteristics. Several new therapeutic targets have been investigated using chemotherapeutics and targeted molecular drugs, however, the intrinsic resistance to induced cell death of brain cells impede the effectiveness of systemic therapies. Also, the unique immune environment of the central nervous system imposes challenges for immune-based therapeutics. Therefore, it is important to consider other approaches to treat these tumors. There is a well-known dose-response relationship for glioblastoma with increased survival with increasing doses, but this effect seems to cap around 60 Gy, due to increased toxicity to the normal brain. Currently, radiation treatment planning of glioblastoma patients relies on CT and MRI that does not visualize the heterogeneous nature of the tumor, and consequently, a homogenous dose is delivered to the entire tumor. Metabolic imaging, such as positron-emission tomography, allows to visualize the heterogeneous tumor environment. Using these metabolic imaging techniques, an approach called dose painting can be used to deliver a higher dose to the tumor regions with high malignancy and/or radiation resistance. Preclinical studies are required for evaluating the benefits of novel radiation treatment strategies, such as PET-based dose painting. The aim of this review is to give a brief overview of promising PET tracers that can be evaluated in laboratory animals to bridge the gap between PET-based dose painting in glioblastoma patients.
Collapse
Affiliation(s)
- Sam Donche
- Department of Radiology and Nuclear Medicine, Ghent University, Ghent, Belgium
| | - Jeroen Verhoeven
- Department of Pharmaceutical Analysis, Ghent University, Ghent, Belgium
| | - Benedicte Descamps
- Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| | - Julie Bolcaen
- Department of Radiology and Nuclear Medicine, Ghent University, Ghent, Belgium
| | - Karel Deblaere
- Department of Radiology and Nuclear Medicine, Ghent University, Ghent, Belgium
| | - Tom Boterberg
- Department of Radiation Oncology and Experimental Cancer Research, Ghent University, Ghent, Belgium
| | | | - Christian Vanhove
- Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| | - Ingeborg Goethals
- Department of Radiology and Nuclear Medicine, Ghent University, Ghent, Belgium
| |
Collapse
|
17
|
Bioluminescence Tomography Guided Small-Animal Radiation Therapy and Tumor Response Assessment. Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.01.068] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
18
|
Wang H, Feng X, Shi B, Liang W, Chen Y, Wang J, Li X. Signal-to-noise ratio analysis and improvement for fluorescence tomography imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:093114. [PMID: 30278730 PMCID: PMC7656320 DOI: 10.1063/1.5045511] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Accepted: 08/30/2018] [Indexed: 05/07/2023]
Abstract
CCD-based fluorescence tomography is widely used for small animal whole-body imaging. In this report, systematic signal-to-noise ratio (SNR) analyses of a fluorescence tomography imaging (FTI) system were performed, resulting in an easy-to-follow strategy to optimize hardware configurations and operational conditions for acquiring high-quality imaging data and for improving the overall system performance. Phantom experiments were conducted to demonstrate the performance improvement by these optimizations. The improved performance was further verified by imaging a tumor-bearing mouse in vivo. This report provides general and practical guidelines for setting up a high-performance electron multiplying charge coupled device based FTI system to achieve an optimized SNR, which can be useful for future FTI technology development.
Collapse
Affiliation(s)
- Huiquan Wang
- Authors to whom correspondence should be addressed: and
| | - Xing Feng
- School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China
| | | | - Wenxuan Liang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205, USA
| | - Yongping Chen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205, USA
| | | | - Xingde Li
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205, USA
| |
Collapse
|