1
|
Romano A, Votta C, Nardini M, Chiloiro G, Panza G, Boldrini L, Cusumano D, Galofaro E, Placidi L, Antonelli MV, Turco G, Autorino R, Gambacorta MA. Uterus motion analysis for radiotherapy planning optimization. The innovative contribution of on-board hybrid MR imaging. Clin Transl Radiat Oncol 2024; 47:100808. [PMID: 39005509 PMCID: PMC11239475 DOI: 10.1016/j.ctro.2024.100808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 05/31/2024] [Accepted: 06/13/2024] [Indexed: 07/16/2024] Open
Abstract
Introduction Organ motion (OM) and volumetric changes pose challenges in radiotherapy (RT) for locally advanced cervical cancer (LACC). Magnetic Resonance-guided Radiotherapy (MRgRT) combines improved MRI contrast with adaptive RT plans for daily anatomical changes. Our goal was to analyze cervico-uterine structure (CUS) changes during RT to develop strategies for managing OM. Materials and methods LACC patients received chemoradiation by MRIdian system with a simultaneous integrated boost (SIB) protocol. Prescription doses of 55-50.6 Gy at PTV1 and 45-39.6 Gy at PTV2 were given in 22 and 25 fractions. Daily MRI scans were co-registered with planning scans and CUS changes were assessed.Six PTVs were created by adding 0.5, 0.7, 1, 1.3, 1.5, and 2 cm margins to the CUS, based on the simulation MRI. Adequate margins were determined to include 95 % of the CUSs throughout the entire treatment in 95 % of patients. Results Analysis of 15 LACC patients and 372 MR scans showed a 31 % median CUS volume decrease. Asymmetric margins of 2 cm cranially, 0.5 cm caudally, 1.5 cm posteriorly, 2 cm anteriorly, and 1.5 cm on both sides were optimal for PTV, adapting to CUS variations. Post-14th fraction, smaller margins of 0.7 cm cranially, 0.5 cm caudally, 1.3 cm posteriorly, 1.3 cm anteriorly, and 1.3 cm on both sides sufficed. Conclusion CUS mobility varies during RT, suggesting reduced PTV margins after the third week. MRgRT with adaptive strategies optimizes dose delivery, emphasizing the importance of streamlined IGRT with reduced PTV margins using a tailored MRgRT workflow with hybrid MRI-guided systems.
Collapse
Affiliation(s)
- Angela Romano
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Claudio Votta
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Matteo Nardini
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Giuditta Chiloiro
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Giulia Panza
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Luca Boldrini
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Davide Cusumano
- Mater Olbia Hospital, Strada Statale Orientale Sarda 125, 07026 Olbia, Italy
| | - Elena Galofaro
- Azienda Ospedaliero Universitaria delle Marche, Via Conca 71, 60126, Ancona, Italy
| | - Lorenzo Placidi
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Marco Valerio Antonelli
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Gabriele Turco
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | - Rosa Autorino
- Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Largo Agostino Gemelli 8, 00168 Rome, Italy
| | | |
Collapse
|
2
|
Wang L, McQuaid D, Blackledge M, McNair H, Harris E, Lalondrelle S. Predicting cervical cancer target motion using a multivariate regression model to enable patient selection for adaptive external beam radiotherapy. Phys Imaging Radiat Oncol 2024; 29:100554. [PMID: 38419803 PMCID: PMC10901141 DOI: 10.1016/j.phro.2024.100554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 02/06/2024] [Accepted: 02/08/2024] [Indexed: 03/02/2024] Open
Abstract
Background and purpose Interfraction motion during cervical cancer radiotherapy is substantial in some patients, minimal in others. Non-adaptive plans may miss the target and/or unnecessarily irradiate normal tissue. Adaptive radiotherapy leads to superior dose-volume metrics but is resource-intensive. The aim of this study was to predict target motion, enabling patient selection and efficient resource allocation. Materials and methods Forty cervical cancer patients had CT with full-bladder (CT-FB) and empty-bladder (CT-EB) at planning, and daily cone-beam CTs (CBCTs). The low-risk clinical target volume (CTVLR) was contoured. Mean coverage of the daily CTVLR by the CT-FB CTVLR was calculated for each patient. Eighty-three investigated variables included measures of organ geometry, patient, tumour and treatment characteristics. Models were trained on 29 patients (171 fractions). The Two-CT multivariate model could use all available data. The Single-CT multivariate model excluded data from the CT-EB. A univariate model was trained using the distance moved by the uterine fundus tip between CTs, the only method of patient selection found in published cervix plan-of-the-day studies. Models were tested on 11 patients (68 fractions). Accuracy in predicting mean coverage was reported as mean absolute error (MAE), mean squared error (MSE) and R2. Results The Two-CT model was based upon rectal volume, dice similarity coefficient between CT-FB and CT-EB CTVLR, and uterine thickness. The Single-CT model was based upon rectal volume, uterine thickness and tumour size. Both performed better than the univariate model in predicting mean coverage (MAE 7 %, 7 % and 8 %; MSE 82 %2, 65 %2, 110 %2; R2 0.2, 0.4, -0.1). Conclusion Uterocervix motion is complex and multifactorial. We present two multivariate models which predicted motion with reasonable accuracy using pre-treatment information, and outperformed the only published method.
Collapse
Affiliation(s)
- Lei Wang
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Dualta McQuaid
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Matthew Blackledge
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Helen McNair
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Emma Harris
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| | - Susan Lalondrelle
- The Joint Department of Physics at the Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, Surrey, UK
| |
Collapse
|
3
|
Chargari C, Tanderup K, Planchamp F, Chiva L, Humphrey P, Sturdza A, Tan LT, van der Steen-Banasik E, Zapardiel I, Nout RA, Fotopoulou C. ESGO/ESTRO quality indicators for radiation therapy of cervical cancer. Radiother Oncol 2023; 183:109589. [PMID: 37268359 DOI: 10.1016/j.radonc.2023.109589] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 01/11/2023] [Indexed: 06/04/2023]
Abstract
BACKGROUND The European Society of Gynaecological Oncology (ESGO) has previously defined and established a list of quality indicators for the surgical treatment of cervical cancer. As a continuation of this effort to improve overall quality of care for cervical cancer patients across all aspects, ESGO and the European SocieTy for Radiotherapy and Oncology (ESTRO) initiated the development of quality indicators for radiation therapy of cervical cancer. OBJECTIVE To develop a list of quality indicators for radiation therapy of cervical cancer that can be used to audit and improve clinical practice by giving to practitioners and administrators a quantitative basis to improve care and organizational processes, notably for recognition of the increased complexity of modern external radiotherapy and brachytherapy techniques. METHODS Quality indicators were based on scientific evidence and/or expert consensus. The development process included a systematic literature search for identification of potential quality indicators and documentation of scientific evidence, consensus meetings of a group of international experts, an internal validation process, and external review by a large international panel of clinicians (n = 99). RESULTS Using a structured format, each quality indicator has a description specifying what the indicator is measuring. Measurability specifications are detailed to define how the quality indicators will be measured in practice. Targets were also defined for specifying the level which each unit or center should be aiming to achieve. Nineteen structural, process, and outcome indicators were defined. Quality indicators 1-6 are general requirements related to pretreatment workup, time to treatment, upfront radiation therapy, and overall management, including active participation in clinical research and the decision making process within a structured multidisciplinary team. Quality indicators 7-17 are related to treatment indicators. Quality indicators 18 and 19 are related to patient outcomes. DISCUSSION This set of quality indicators is a major instrument to standardize the quality of radiation therapy in cervical cancer. A scoring system combining surgical and radiotherapeutic quality indicators will be developed within an envisaged future ESGO accreditation process for the overall management of cervical cancer, in an effort to support institutional and governmental quality assurance programs.
Collapse
Affiliation(s)
| | | | | | - Luis Chiva
- Obstetrics and Gynecology, Clinica Universidad de Navarra, Madrid, Spain
| | - Pauline Humphrey
- University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| | - Alina Sturdza
- Department of Radiation Oncology, Comprehensive Cancer Center, Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Wien, Austria
| | - Li T Tan
- Addenbrooke's Hospital, Cambridge, UK
| | | | | | - Remi A Nout
- Radiotherapy, Erasmus MC Cancer Centre, Rotterdam, the Netherlands
| | | |
Collapse
|
4
|
Chargari C, Tanderup K, Planchamp F, Chiva L, Humphrey P, Sturdza A, Tan LT, van der Steen-Banasik E, Zapardiel I, Nout RA, Fotopoulou C. ESGO/ESTRO quality indicators for radiation therapy of cervical cancer. Int J Gynecol Cancer 2023:ijgc-2022-004180. [PMID: 37258414 DOI: 10.1136/ijgc-2022-004180] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/02/2023] Open
Abstract
BACKGROUND The European Society of Gynaecological Oncology (ESGO) has previously defined and established a list of quality indicators for the surgical treatment of cervical cancer. As a continuation of this effort to improve overall quality of care for cervical cancer patients across all aspects, ESGO and the European SocieTy for Radiotherapy and Oncology (ESTRO) initiated the development of quality indicators for radiation therapy of cervical cancer. OBJECTIVE To develop a list of quality indicators for radiation therapy of cervical cancer that can be used to audit and improve clinical practice by giving to practitioners and administrators a quantitative basis to improve care and organizational processes, notably for recognition of the increased complexity of modern external radiotherapy and brachytherapy techniques. METHODS Quality indicators were based on scientific evidence and/or expert consensus. The development process included a systematic literature search for identification of potential quality indicators and documentation of scientific evidence, consensus meetings of a group of international experts, an internal validation process, and external review by a large international panel of clinicians (n=99). RESULTS Using a structured format, each quality indicator has a description specifying what the indicator is measuring. Measurability specifications are detailed to define how the quality indicators will be measured in practice. Targets were also defined for specifying the level which each unit or center should be aiming to achieve. Nineteen structural, process, and outcome indicators were defined. Quality indicators 1-6 are general requirements related to pretreatment workup, time to treatment, upfront radiation therapy, and overall management, including active participation in clinical research and the decision making process within a structured multidisciplinary team. Quality indicators 7-17 are related to treatment indicators. Quality indicators 18 and 19 are related to patient outcomes. DISCUSSION This set of quality indicators is a major instrument to standardize the quality of radiation therapy in cervical cancer. A scoring system combining surgical and radiotherapeutic quality indicators will be developed within an envisaged future ESGO accreditation process for the overall management of cervical cancer, in an effort to support institutional and governmental quality assurance programs.
Collapse
Affiliation(s)
| | | | | | - Luis Chiva
- Obstetrics and Gynecology, Clinica Universidad de Navarra, Madrid, Spain
| | - Pauline Humphrey
- University Hospitals Bristol and Weston NHS Foundation Trust, Bristol, UK
| | - Alina Sturdza
- Department of Radiation Oncology, Comprehensive Cancer Center, Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Wien, Austria
| | - Li T Tan
- Addenbrooke's Hospital, Cambridge, UK
| | | | | | - Remi A Nout
- Radiotherapy, Erasmus MC Cancer Centre, Rotterdam, Netherlands
| | | |
Collapse
|
5
|
Wang L, Alexander S, Mason S, Blasiak-Wal I, Harris E, McNair H, Lalondrelle S. Carpe Diem: Making the Most of Plan-of-the-Day for Cervical Cancer Radiation Therapy. Pract Radiat Oncol 2023; 13:132-147. [PMID: 36481683 DOI: 10.1016/j.prro.2022.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2022] [Revised: 10/26/2022] [Accepted: 11/03/2022] [Indexed: 12/12/2022]
Abstract
PURPOSE Radiation therapy is the key treatment for locally advanced cervical cancer. Organ motion presents a challenge to accurate targeting of external beam radiation therapy. The plan-of-the-day (PotD) adaptive approach is therefore an attractive option. We present our experience and the procedural steps required to implement PotD for cervix cancer. METHODS AND MATERIALS We reviewed relevant studies on organ motion and adaptive radiation therapy identified through a literature search and cross referencing. These included 10 dosimetric and 3 quality of life studies directly assessing the PotD approach to radiation therapy in cervix cancer. RESULTS Studies show improvements in target coverage and reduction of dose received by normal tissues and suggest improved toxicity. Clinical implementation of PotD has been slow because of a number of difficulties and uncertainties, which we discuss with the aim of helping teams to implement PotD at their center. CONCLUSIONS The PotD approach improves dosimetry and may improve toxicity. We describe a framework to assist with practical implementation.
Collapse
Affiliation(s)
- Lei Wang
- The Joint Department of Physics at the Institute of Cancer Research, Sutton, Surrey, United Kingdom.
| | - Sophie Alexander
- Radiotherapy Department, Royal Marsden NHS Foundation Trust, Sutton, Surrey, United Kingdom
| | - Sarah Mason
- The Joint Department of Physics at the Institute of Cancer Research, Sutton, Surrey, United Kingdom
| | - Irena Blasiak-Wal
- The Joint Department of Physics at the Institute of Cancer Research, Sutton, Surrey, United Kingdom
| | - Emma Harris
- The Joint Department of Physics at the Institute of Cancer Research, Sutton, Surrey, United Kingdom
| | - Helen McNair
- Radiotherapy Department, Royal Marsden NHS Foundation Trust, Sutton, Surrey, United Kingdom
| | - Susan Lalondrelle
- The Joint Department of Physics at the Institute of Cancer Research, Sutton, Surrey, United Kingdom
| |
Collapse
|
6
|
Zhang C, Lafond C, Barateau A, Leseur J, Rigaud B, Chan Sock Line DB, Yang G, Shu H, Dillenseger JL, de Crevoisier R, Simon A. Automatic segmentation for plan-of-the-day selection in CBCT-guided adaptive radiation therapy of cervical cancer. Phys Med Biol 2022; 67. [PMID: 36541494 DOI: 10.1088/1361-6560/aca5e5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 11/24/2022] [Indexed: 11/25/2022]
Abstract
Objective.Plan-of-the-day (PoD) adaptive radiation therapy (ART) is based on a library of treatment plans, among which, at each treatment fraction, the PoD is selected using daily images. However, this strategy is limited by PoD selection uncertainties. This work aimed to propose and evaluate a workflow to automatically and quantitatively identify the PoD for cervix cancer ART based on daily CBCT images.Approach.The quantification was based on the segmentation of the main structures of interest in the CBCT images (clinical target volume [CTV], rectum, bladder, and bowel bag) using a deep learning model. Then, the PoD was selected from the treatment plan library according to the geometrical coverage of the CTV. For the evaluation, the resulting PoD was compared to the one obtained considering reference CBCT delineations.Main results.In experiments on a database of 23 patients with 272 CBCT images, the proposed method obtained an agreement between the reference PoD and the automatically identified PoD for 91.5% of treatment fractions (99.6% when considering a 5% margin on CTV coverage).Significance.The proposed automatic workflow automatically selected PoD for ART using deep-learning methods. The results showed the ability of the proposed process to identify the optimal PoD in a treatment plan library.
Collapse
Affiliation(s)
- Chen Zhang
- Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.,Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France.,Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China
| | - Caroline Lafond
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France
| | - Anaïs Barateau
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France
| | - Julie Leseur
- Radiotherapy Department, CLCC Eugène Marquis, F-35000 Rennes, France
| | - Bastien Rigaud
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France
| | | | - Guanyu Yang
- Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.,Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.,Centre de Recherche en Information Biomédical Sino-français (CRIBs), France
| | - Huazhong Shu
- Laboratory of Image Science and Technology, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.,Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing, School of Computer Science and Engineering, Southeast University, Nanjing, People's Republic of China.,Centre de Recherche en Information Biomédical Sino-français (CRIBs), France
| | - Jean-Louis Dillenseger
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France.,Centre de Recherche en Information Biomédical Sino-français (CRIBs), France
| | | | - Antoine Simon
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France.,Centre de Recherche en Information Biomédical Sino-français (CRIBs), France
| |
Collapse
|
7
|
de Crevoisier R, Lafond C, Mervoyer A, Hulot C, Jaksic N, Bessières I, Delpon G. Image-guided radiotherapy. Cancer Radiother 2021; 26:34-49. [PMID: 34953701 DOI: 10.1016/j.canrad.2021.08.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
We present the updated recommendations of the French society for oncological radiotherapy on image-guided radiotherapy (IGRT). The objective of the IGRT is to take into account the anatomical variations of the target volume occurring between or during the irradiation fractions, such as displacements and/or deformations, so that the delivered dose corresponds to the planned dose. This article presents the different IGRT devices, their use and quality control, and quantify the possible additional dose generated by each of them. The practical implementation of IGRT in various tumour locations is summarised, from the different "RecoRad™" guideline articles. Adaptive radiotherapy is then detailed, due to its complexity and its probable development in the next years. The place of radiation technologist in the practice of IGRT is then specified. Finally, a brief update is proposed on the delicate question of the additional dose linked to the in-room imaging, which must be estimated and documented at a minimum, as long as it is difficult to integrate it into the calculation of the dose distribution.
Collapse
Affiliation(s)
- R de Crevoisier
- Radiotherapy department, centre régional de lutte contre le cancer Eugène Marquis, 35042 Rennes, France.
| | - C Lafond
- Radiotherapy department, centre régional de lutte contre le cancer Eugène Marquis, 35042 Rennes, France
| | - A Mervoyer
- Radiotherapy department, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint Herblain, France; Medical physics department, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint Herblain, France
| | - C Hulot
- Radiotherapy department, centre régional de lutte contre le cancer Eugène Marquis, 35042 Rennes, France
| | - N Jaksic
- Radiotherapy department, centre régional de lutte contre le cancer Eugène Marquis, 35042 Rennes, France
| | - I Bessières
- Medical physics department, centre Georges-François Leclerc, rue du Professeur-Marion, 21000 Dijon, France
| | - G Delpon
- Radiotherapy department, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint Herblain, France; Medical physics department, institut de cancérologie de l'Ouest René-Gauducheau, boulevard Jacques-Monod, 44805 Saint Herblain, France
| |
Collapse
|
8
|
Set-Up Errors, Organ Motion, Tumour Regression and its Implications on Internal Target Volume-Planning Target Volume During Cervical Cancer Radiotherapy: Results From a Prospective Study. Clin Oncol (R Coll Radiol) 2021; 34:189-197. [PMID: 34736842 DOI: 10.1016/j.clon.2021.10.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 08/24/2021] [Accepted: 10/19/2021] [Indexed: 11/20/2022]
Abstract
AIMS Uterocervical motions and organ filling during cervical cancer conformal radiotherapy is complex. This prospective, observational study investigated set-up margins (clinical target vo, ume [CTV] to planning target volume [PTV]) for pelvic nodal CTV and internal margin (CTV to internal target volume [ITV]) expansions for uterocervical movements during cervical cancer radiotherapy. MATERIALS AND METHODS During cervical cancer radiotherapy, a daily kilovoltage, cone-beam computed tomography (CBCT) scan was acquired. Bony anatomy-based rigid co-registration and matching to vessels/pelvic nodal region was carried out to document shifts, errors (systematic and random) and to calculate CTV to PTV margins. Subsequently, soft-tissue matching was carried out at the mid-cervical region and uterine fundus to record shifts, errors and to calculate CTV to ITV margins. RESULTS In 67 patients, 1380 CBCT scans were analysed. The mean (±standard deviation) couch shifts for CTV pelvic nodal region in all directions were within 4.5-5.3 mm, systematic and random errors 3.0-3.6 mm and set-up margins of within 10 mm (except anterior margin 10.3 mm). For the mid-cervical region, mean shifts were 4.5-5.5 mm, systematic and random errors 2-4 mm amounting to <10 mm internal margins (CTV-ITV for cervix) and for uterine fundus mean (±standard deviation) shifts were larger in the superior direction (12.1 mm) but 4.0-7.5 mm in other directions, systematic and random errors 2-7 mm amounting to anisotropic margins in various directions (10 mm in anterior-posterior and lateral directions, 12-20 mm in superior-inferior directions) (CTV-ITV for uterine fundus). CONCLUSION Our study suggests anisotropic CTV to ITV and CTV to PTV margins for cervical cancer radiotherapy.
Collapse
|
9
|
Crop F, Comte P, Le Tinier F, Pasquier D, Mirabel X. Evaluation of an ultrasound bladder scanner in supine and standing position. J Appl Clin Med Phys 2021; 22:194-202. [PMID: 34676959 PMCID: PMC8664133 DOI: 10.1002/acm2.13424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 08/25/2021] [Accepted: 08/30/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE This study examined the performance of a bladder volume measuring device, the BladderScan (BS) BVI9400. The use of the BS offers the possibility of assessing the bladder volume before positioning the patient and performing the daily image-guided radiotherapy procedure. Patients often cannot lie down before entering the treatment vault. Therefore, the BS was also assessed in a standing position. METHODS The repeatability precision was first evaluated, which is the variability of immediate repeated measures of the BS with same operator and subject. This was followed by the reproducibility precision of the BS in which the operator and subjects differ. Finally, the trueness was evaluated in terms of fixed and proportional bias of the results by applying weighted least-squares fitting. Note that 53 and 85 patient measurements were carried out in supine and standing position, respectively, each consisting of three repeated BS measurements. These were compared with the computed tomography (CT)-delineated bladder volume. RESULTS Repeatability was dependent on measurement value (heteroscedasticity) with σrepeatability (BS) = ±15 cm3 ± 10%. However, the total agreement between BS and CT was low with the 95% limits of agreement (LOAs) exceeding ±200 cm3 due to poor patient reproducibility and presence of fixed and proportional bias. Only in the best case of male patients in the supine position, three BS measurements, and correction for the fixed and proportional bias, 95% LOAs of [-147, +114] cm3 were obtained between CT and BS. CONCLUSION The agreement of the BVI9400 BS with CT was found to be too low for radiotherapy applications.
Collapse
Affiliation(s)
- Frederik Crop
- Department of Medical Physics, Centre Oscar Lambret, Lille, France
| | - Pauline Comte
- Department of Medical Physics, Centre Oscar Lambret, Lille, France
| | - Florence Le Tinier
- Academic Department of Radiotherapy, Centre Oscar Lambret, Lille, France
| | - David Pasquier
- Academic Department of Radiotherapy, Centre Oscar Lambret, Lille, France
| | - Xavier Mirabel
- Academic Department of Radiotherapy, Centre Oscar Lambret, Lille, France
| |
Collapse
|
10
|
Li X, Wang L, Cui Z, Li Y, Liu P, Wang Y, Zhu J, Zhu J, Yin Y, Li Z. Online MR evaluation of inter- and intra-fraction uterus motions and bladder volume changes during cervical cancer external beam radiotherapy. Radiat Oncol 2021; 16:179. [PMID: 34535161 PMCID: PMC8447532 DOI: 10.1186/s13014-021-01907-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Accepted: 09/06/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose/objective(s) The purpose of the study was to assess the uterus motions and bladder volume changes of fractional movements in cervical sites throughout the external beam radiotherapy (EBRT) treatment. Materials/methods A prospective online MR imaging tracking study was conducted in EBRT 43 patients with at least 4 scans during each treatment (before: ultrasound scan, MRI scan, CBCT scan, after: MRI scan) were included. In order to improve the treatment repeatability, each patient was instructed to empty the bladder and drink 500 ml water 1 h before CT simulation and each treatment. If the ultrasound scan result reached the CT simulation volume of bladder, the treatment began. Bladder was outlined on the T2 weighted axial sequence and CBCT image by the two observers to avoid the influence of contouring. The data of bladder volume and scanning time were accurately recorded. The bladder volumes, filling rates and uterus motion were retrospectively analyzed by MIM software. Results Inter-fraction variation of the bladder volume was significant (p < 0.0001). Intra-fraction mean increase of the bladder volume was modest (30 cc) but significant (p < 0.001). Both inter- and intra-fraction of the uterus motion were significant. The average time between the pre-and post-fraction MRI scans was 27.82 ± 7.12 min (range 10–55 min) for IMRT plans and 24.14 ± 5.86 min (range7-38 min) for VMAT plan. Average bladder filling rate was 3.43 ml/min. The bladder filling rate did not change significantly with the course of treatment, but the bladder was more intolerant. Conclusion This is the most detailed assessment of intra-fraction and inter-fraction motion during EBRT for cervical cancer. Finally, this study will inform appropriate treatment margins for online adaptive radiotherapy. We suggest that at least one image scan is needed before the EBRT. The portable US scanner provides a quick but unreliable measurement of the bladder volume. There is a significant statistical difference between the results of ultrasonic scanning and that of image scanning.
Collapse
Affiliation(s)
- Xu Li
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Lizhen Wang
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Zhen Cui
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Yukun Li
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Pei Liu
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Yungang Wang
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Jinhong Zhu
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Jianmin Zhu
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China
| | - Yong Yin
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China.
| | - Zhenjiang Li
- Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, No.440 Jiyan road, Huaiyin district, Jinan City, 250117, Shandong Province, China.
| |
Collapse
|
11
|
Vidal M, Moignier C, Patriarca A, Sotiropoulos M, Schneider T, De Marzi L. Future technological developments in proton therapy - A predicted technological breakthrough. Cancer Radiother 2021; 25:554-564. [PMID: 34272182 DOI: 10.1016/j.canrad.2021.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 06/18/2021] [Indexed: 12/13/2022]
Abstract
In the current spectrum of cancer treatments, despite high costs, a lack of robust evidence based on clinical outcomes or technical and radiobiological uncertainties, particle therapy and in particular proton therapy (PT) is rapidly growing. Despite proton therapy being more than fifty years old (first proposed by Wilson in 1946) and more than 220,000 patients having been treated with in 2020, many technological challenges remain and numerous new technical developments that must be integrated into existing systems. This article presents an overview of on-going technical developments and innovations that we felt were most important today, as well as those that have the potential to significantly shape the future of proton therapy. Indeed, efforts have been done continuously to improve the efficiency of a PT system, in terms of cost, technology and delivery technics, and a number of different developments pursued in the accelerator field will first be presented. Significant developments are also underway in terms of transport and spatial resolution achievable with pencil beam scanning, or conformation of the dose to the target: we will therefore discuss beam focusing and collimation issues which are important parameters for the development of these techniques, as well as proton arc therapy. State of the art and alternative approaches to adaptive PT and the future of adaptive PT will finally be reviewed. Through these overviews, we will finally see how advances in these different areas will allow the potential for robust dose shaping in proton therapy to be maximised, probably foreshadowing a future era of maturity for the PT technique.
Collapse
Affiliation(s)
- M Vidal
- Centre Antoine-Lacassagne, Fédération Claude Lalanne, 227, avenue de la Lanterne, 06200 Nice, France
| | - C Moignier
- Centre François Baclesse, Department of Medical Physics, Centre de protonthérapie de Normandie, 14000 Caen, France
| | - A Patriarca
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France
| | - M Sotiropoulos
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - T Schneider
- Institut Curie, Université PSL, CNRS UMR3347, Inserm U1021, Signalisation radiobiologie et cancer, 91400 Orsay, France
| | - L De Marzi
- Institut Curie, PSL Research University, Radiation oncology department, Centre de protonthérapie d'Orsay, Campus universitaire, bâtiment 101, 91898 Orsay, France; Institut Curie, PSL Research University, University Paris Saclay, Inserm LITO, Campus universitaire, 91898 Orsay, France.
| |
Collapse
|
12
|
Rigaud B, Anderson BM, Yu ZH, Gobeli M, Cazoulat G, Söderberg J, Samuelsson E, Lidberg D, Ward C, Taku N, Cardenas C, Rhee DJ, Venkatesan AM, Peterson CB, Court L, Svensson S, Löfman F, Klopp AH, Brock KK. Automatic Segmentation Using Deep Learning to Enable Online Dose Optimization During Adaptive Radiation Therapy of Cervical Cancer. Int J Radiat Oncol Biol Phys 2021; 109:1096-1110. [DOI: 10.1016/j.ijrobp.2020.10.038] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 10/24/2020] [Accepted: 10/29/2020] [Indexed: 02/08/2023]
|
13
|
Soror T, Siebert FA, Lancellotta V, Placidi E, Fionda B, Tagliaferri L, Kovács G. Quality Assurance in Modern Gynecological HDR-Brachytherapy (Interventional Radiotherapy): Clinical Considerations and Comments. Cancers (Basel) 2021; 13:cancers13040912. [PMID: 33671552 PMCID: PMC7927078 DOI: 10.3390/cancers13040912] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 11/16/2022] Open
Abstract
Simple Summary This is a focused review discussing quality assurance during interventional brachytherapy in gynecological cancers. This topic is very large and is usually addressed from the technical and physical sides, therefore, we decided to select “hot-spots” under this large title and discuss them from the point of view of clinicians. We hope that this concise and focused review will help clinicians in improving their quality assurance protocols and draw attention to the discussed issues. Abstract The use of brachytherapy (interventional radiotherapy) in the treatment of gynecological cancers is a crucial element in both definitive and adjuvant settings. The recent developments in high-dose rate remote afterloaders, modern applicators, treatment-planning software, image guidance, and dose monitoring systems have led to improvement in the local control rates and in some cases improved the survival rates. The development of these highly advanced and complicated treatment modalities has been accompanied by challenges, which have made the existence of quality assurance protocols a must to ensure the integrity of the treatment process. Quality assurance aims at standardizing the technical and clinical procedures involved in the treatment of patients, which could eventually decrease the source of uncertainties whether technical (source/equipment related) or clinical. This commentary review sheds light (from a clinical point of view) on some potential sources of uncertainties associated with the use of modern brachytherapy in the treatment of gynecological cancers.
Collapse
Affiliation(s)
- Tamer Soror
- Radiation Oncology Department, University of Lübeck/UKSH-CL, 23538 Lübeck, Germany
- Radiation Oncology Department, National Cancer Institute (NCI), Cairo University, Cairo 11796, Egypt
- Correspondence: ; Tel.: +49-176-2369-5626
| | - Frank-André Siebert
- Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, 24105 Campus Kiel, Germany;
| | - Valentina Lancellotta
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Roma, Italy; (V.L.); (E.P.); (B.F.); (L.T.)
| | - Elisa Placidi
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Roma, Italy; (V.L.); (E.P.); (B.F.); (L.T.)
| | - Bruno Fionda
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Roma, Italy; (V.L.); (E.P.); (B.F.); (L.T.)
| | - Luca Tagliaferri
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Roma, Italy; (V.L.); (E.P.); (B.F.); (L.T.)
| | - György Kovács
- Università Cattolica del Sacro Cuore, Radioterapia Oncologica, Gemelli-INTERACTS, 00168 Roma, Italy;
| |
Collapse
|
14
|
Beekman C, Beek S, Stam J, Sonke J, Remeijer P. A biomechanical finite element model to generate a library of cervix CTVs. Med Phys 2020; 47:3852-3860. [DOI: 10.1002/mp.14349] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 06/09/2020] [Accepted: 06/11/2020] [Indexed: 02/03/2023] Open
Affiliation(s)
- Chris Beekman
- Department of Radiation Oncology The Netherlands Cancer Institute Amsterdam The Netherlands
| | - Suzanne Beek
- Department of Radiation Oncology The Netherlands Cancer Institute Amsterdam The Netherlands
| | - Jikke Stam
- Department of Radiation Oncology The Netherlands Cancer Institute Amsterdam The Netherlands
| | - Jan‐Jakob Sonke
- Department of Radiation Oncology The Netherlands Cancer Institute Amsterdam The Netherlands
| | - Peter Remeijer
- Department of Radiation Oncology The Netherlands Cancer Institute Amsterdam The Netherlands
| |
Collapse
|
15
|
Bleeker M, Goudschaal K, Bel A, Sonke JJ, Hulshof MCCM, van der Horst A. Feasibility of cone beam CT-guided library of plans strategy in pre-operative gastric cancer radiotherapy. Radiother Oncol 2020; 149:49-54. [PMID: 32387491 DOI: 10.1016/j.radonc.2020.04.057] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 04/29/2020] [Accepted: 04/29/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND PURPOSE The stomach displays large anatomical changes in size, shape and position, which implies the need for plan adaptation for gastric cancer patients who receive pre-operative radiotherapy. We evaluated the feasibility and necessity of a CBCT-guided library of plans (LoP) strategy in gastric cancer radiotherapy. METHODS Eight gastric cancer patients treated with 24-25 fractions of single-plan radiotherapy with daily CBCT imaging were included. The target was delineated on the pre-treatment CT and first 5 CBCTs to create a patient-specific LoP. Plan selections were performed by 12 observers in a training stage (2-3 CBCTs per patient) and an assessment stage (17 CBCTs per patient). The observers were asked to select the smallest plan that encompassed the target on the CBCT. A total of 136 plan selections were evaluated in the assessment stage. RESULTS Delineations on CBCTs showed that in 90% of the 40 delineated fractions part of the CTV was outside the PTV based on the pre-treatment CT. At least two-thirds of the observers agreed on the selected plan in 65.2% and 70% of the fractions in the training stage and the assessment stage, respectively. For each patient, at least two different plans from the LoP were the most selected plan. CONCLUSION A CBCT-guided patient-specific LoP strategy is feasible for gastric cancer patients, yielding good agreement in plan selections. Unless generous margins are used to avoid frequent geometric misses, it is likely that part of the target will be missed with single-plan radiotherapy.
Collapse
Affiliation(s)
- Margot Bleeker
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
| | - Karin Goudschaal
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Arjan Bel
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands; Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Maarten C C M Hulshof
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Astrid van der Horst
- Department of Radiation Oncology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
16
|
Rigaud B, Cazoulat G, Vedam S, Venkatesan AM, Peterson CB, Taku N, Klopp AH, Brock KK. Modeling Complex Deformations of the Sigmoid Colon Between External Beam Radiation Therapy and Brachytherapy Images of Cervical Cancer. Int J Radiat Oncol Biol Phys 2020; 106:1084-1094. [PMID: 32029345 DOI: 10.1016/j.ijrobp.2019.12.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 12/13/2019] [Accepted: 12/19/2019] [Indexed: 02/07/2023]
Abstract
PURPOSE In this study, we investigated registration methods for estimating the large interfractional sigmoid deformations that occur between external beam radiation therapy (EBRT) and brachytherapy (BT) for cervical cancer. METHODS AND MATERIALS Sixty-three patients were retrospectively analyzed. The sigmoid colon was delineated on 2 computed tomography images acquired during EBRT (without applicator) and BT (with applicator) for each patient. Five registration approaches were compared to propagate the contour of the sigmoid from BT to EBRT anatomies: rigid registration, commercial hybrid (ANAtomically CONstrained Deformation Algorithm), controlling ROI surface projection of RayStation, and the classical and constrained symmetrical thin-plate spline robust point matching (sTPS-RPM) methods. Deformation of the sigmoid due to insertion of the BT applicator was reported. Registration performance was compared by using the Dice similarity coefficient (DSC), distance to agreement, and Hausdorff distance. The 2 sTPS-RPM methods were compared by using surface triangle quality criteria between deformed surfaces. Using the deformable approaches, the BT dose of the sigmoid was deformed toward the EBRT anatomy. The displacement and discrepancy between the deformable methods to propagate the planned D1cm3 and D2cm3 of the sigmoid from BT to EBRT anatomies were reported for 55 patients. RESULTS Large and complex deformations of the sigmoid were observed for each patient. Rigid registration resulted in poor sigmoid alignment with a mean DSC of 0.26. Using the contour to drive the deformation, ANAtomically CONstrained Deformation Algorithm was able to slightly improve the alignment of the sigmoid with a mean DSC of 0.57. Using only the sigmoid surface as controlling ROI, the mean DSC was improved to 0.79. The classical and constrained sTPS-RPM methods provided mean DSCs of 0.95 and 0.96, respectively, with an average inverse consistency error <1 mm. The constrained sTPS-RPM provided more realistic deformations and better surface topology of the deformed sigmoids. The planned mean (range) D1cm3 and D2cm3 of the sigmoid were 13.4 Gy (1-24.1) and 12.2 Gy (1-21.5) on the BT anatomy, respectively. Using the constrained sTPS-RPM to deform the sigmoid from BT to EBRT anatomies, these hotspots had a mean (range) displacement of 27.1 mm (6.8-81). CONCLUSIONS Large deformations of the sigmoid were observed between the EBRT and BT anatomies, suggesting that the D1cm3 and D2cm3 of the sigmoid would unlikely to be at the same position throughout treatment. The proposed constrained sTPS-RPM seems to be the preferred approach to manage the large deformation due to BT applicator insertion. Such an approach could be used to map the EBRT dose to the BT anatomy for personalized BT planning optimization.
Collapse
Affiliation(s)
- Bastien Rigaud
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas.
| | - Guillaume Cazoulat
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Sastry Vedam
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Aradhana M Venkatesan
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Christine B Peterson
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Nicolette Taku
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Ann H Klopp
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Kristy K Brock
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
17
|
Boldrini L, Piras A, Chiloiro G, Autorino R, Cellini F, Cusumano D, Fionda B, D'Aviero A, Campitelli M, Marazzi F, Balducci M, Valentini V, Gambacorta MA. Low Tesla magnetic resonance guided radiotherapy for locally advanced cervical cancer: first clinical experience. TUMORI JOURNAL 2020; 106:497-505. [PMID: 32066345 DOI: 10.1177/0300891620901752] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE Magnetic resonance-guided radiotherapy (MRgRT) represents an innovative approach for personalized radiotherapy treatments and its applications are being explored in various anatomical sites to fully understand its potential advantages. This study describes the first clinical experience of MRgRT application in patients with locally advanced cervical cancer (LACC) undergoing neoadjuvant chemoradiotherapy. The feasibility of the technique is evaluated and its toxicity profile and clinical outcomes are reported. METHODS Patients with LACC (International Federation of Gynecology and Obstetrics stage IIA-IVA) undergoing neoadjuvant chemoradiotherapy (CRT) on a 0.35T Tri-60-Co hybrid unit (ViewRay) were retrospectively compared with randomly selected patients treated with a standard linear accelerator. Total prescribed dose was 50.6 Gy (2.3 Gy/fraction) to planning target volume 1 (PTV1) and 39.6 Gy (1.8 Gy/fraction) to PTV2, delivered using a simultaneous integrated boost. Surgery was performed 8 weeks after the end of CRT. The effect of magnetic resonance guidance on replanning approaches, treatment-related toxicities, and pathologic response were assessed for each patient. Patient outcomes were noted and dosimetric comparisons performed between the 2 arms. RESULTS Nine patients with LACC treated from May 2018 to November 2018 were retrospectively enrolled and their records compared with the records of an equivalent cohort of randomly selected patients. Five replanning cases were performed in the MRgRT group and 0 in the linear accelerator group. Acute G1-G2 gastrointestinal toxicities were observed in 33.3% of MRgRT patients and in 55.5% of linear accelerator patients; acute G1-G2 genitourinary toxicities in 22.2% and 33.3%, respectively. No G3 toxicity was found except for neutropenia in 2 patients. No differences were observed in pathologic response between the 2 groups. CONCLUSIONS Despite the retrospective nature of the observations and the low number of enrolled patients, the application of MRgRT in LACC appears to be safe and feasible with a favorable toxicity profile and response rates comparable to gold standard, supporting the setup of larger prospective studies to investigate the potentialities of this new technology.
Collapse
Affiliation(s)
- Luca Boldrini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Antonio Piras
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giuditta Chiloiro
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Rosa Autorino
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Francesco Cellini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Davide Cusumano
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Fisica Sanitaria, Rome, Italy
| | - Bruno Fionda
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Andrea D'Aviero
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Maura Campitelli
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Fabio Marazzi
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy
| | - Mario Balducci
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy.,Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Vincenzo Valentini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy.,Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Maria Antonietta Gambacorta
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, UOC di Radioterapia Oncologica, Rome, Italy.,Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
18
|
Swamidas J, Kirisits C, De Brabandere M, Hellebust TP, Siebert FA, Tanderup K. Image registration, contour propagation and dose accumulation of external beam and brachytherapy in gynecological radiotherapy. Radiother Oncol 2020; 143:1-11. [DOI: 10.1016/j.radonc.2019.08.023] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 08/23/2019] [Accepted: 08/28/2019] [Indexed: 02/07/2023]
|
19
|
État des lieux de la radiothérapie adaptative en 2019 : de la mise en place à l’utilisation clinique. Cancer Radiother 2019; 23:581-591. [DOI: 10.1016/j.canrad.2019.07.142] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Accepted: 07/12/2019] [Indexed: 12/20/2022]
|
20
|
Rigaud B, Simon A, Castelli J, Lafond C, Acosta O, Haigron P, Cazoulat G, de Crevoisier R. Deformable image registration for radiation therapy: principle, methods, applications and evaluation. Acta Oncol 2019; 58:1225-1237. [PMID: 31155990 DOI: 10.1080/0284186x.2019.1620331] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Background: Deformable image registration (DIR) is increasingly used in the field of radiation therapy (RT) to account for anatomical deformations. The aims of this paper are to describe the main applications of DIR in RT and discuss current DIR evaluation methods. Methods: Articles on DIR published from January 2000 to October 2018 were extracted from PubMed and Science Direct. Our search was restricted to articles that report data obtained from humans, were written in English, and address DIR methods for RT. A total of 207 articles were selected from among 2506 identified in the search process. Results: At planning, DIR is used for organ delineation using atlas-based segmentation, deformation-based planning target volume definition, functional planning and magnetic resonance imaging-based dose calculation. In image-guided RT, DIR is used for contour propagation and dose calculation on per-treatment imaging. DIR is also used to determine the accumulated dose from fraction to fraction in external beam RT and brachytherapy, both for dose reporting and adaptive RT. In the case of re-irradiation, DIR can be used to estimate the cumulated dose of the two irradiations. Finally, DIR can be used to predict toxicity in voxel-wise population analysis. However, the evaluation of DIR remains an open issue, especially when dealing with complex cases such as the disappearance of matter. To quantify DIR uncertainties, most evaluation methods are limited to geometry-based metrics. Software companies have now integrated DIR tools into treatment planning systems for clinical use, such as contour propagation and fraction dose accumulation. Conclusions: DIR is increasingly important in RT applications, from planning to toxicity prediction. DIR is routinely used to reduce the workload of contour propagation. However, its use for complex dosimetric applications must be carefully evaluated by combining quantitative and qualitative analyses.
Collapse
Affiliation(s)
- Bastien Rigaud
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Antoine Simon
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Joël Castelli
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Caroline Lafond
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Oscar Acosta
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Pascal Haigron
- CLCC Eugène Marquis, University of Rennes, Inserm , Rennes , France
| | - Guillaume Cazoulat
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center , Houston , TX , USA
| | | |
Collapse
|
21
|
Rigaud B, Klopp A, Vedam S, Venkatesan A, Taku N, Simon A, Haigron P, de Crevoisier R, Brock KK, Cazoulat G. Deformable image registration for dose mapping between external beam radiotherapy and brachytherapy images of cervical cancer. Phys Med Biol 2019; 64:115023. [PMID: 30913542 DOI: 10.1088/1361-6560/ab1378] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
For locally advanced cervical cancer (LACC), anatomy correspondence with and without BT applicator needs to be quantified to merge the delivered doses of external beam radiation therapy (EBRT) and brachytherapy (BT). This study proposed and evaluated different deformable image registration (DIR) methods for this application. Twenty patients who underwent EBRT and BT for LACC were retrospectively analyzed. Each patient had a pre-BT CT at EBRT boost (without applicator) and a CT and MRI at BT (with applicator). The evaluated DIR methods were the diffeomorphic Demons, commercial intensity and hybrid methods, and three different biomechanical models. The biomechanical models considered different boundary conditions (BCs). The impact of the BT devices insertion on the anatomy was quantified. DIR method performances were quantified using geometric criteria between the original and deformed contours. The BT dose was deformed toward the pre-CT BT by each DIR method. The impact of boundary conditions to drive the biomechanical model was evaluated based on the deformation vector field and dose differences. The GEC-ESTRO guideline dose indices were reported. Large organ displacements, deformations, and volume variations were observed between the pre-BT and BT anatomies. Rigid registration and intensity-based DIR resulted in poor geometric accuracy with mean Dice similarity coefficient (DSC) inferior to 0.57, 0.63, 0.42, 0.32, and 0.43 for the rectum, bladder, vagina, cervix and uterus, respectively. Biomechanical models provided a mean DSC of 0.96 for all the organs. By considering the cervix-uterus as one single structure, biomechanical models provided a mean DSC of 0.88 and 0.94 for the cervix and uterus, respectively. The deformed doses were represented for each DIR method. Caution should be used when performing DIR for this application as standard techniques may have unacceptable results. The biomechanical model with the cervix-uterus as one structure provided the most realistic deformations to propagate the BT dose toward the EBRT boost anatomy.
Collapse
Affiliation(s)
- B Rigaud
- Univ Rennes, CLCC Eugène Marquis, Inserm, LTSI-UMR 1099, F-35000 Rennes, France. Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Radiothérapie guidée par l’image des cancers gynécologiques. Cancer Radiother 2018; 22:608-616. [DOI: 10.1016/j.canrad.2018.06.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Accepted: 06/26/2018] [Indexed: 11/24/2022]
|