Chi DD, Toan TN, Hill R. A multi-detector comparison to determine convergence of measured relative output factors for small field dosimetry. Phys Eng Sci Med 2024; 47:371-379. [PMID: 37943444 DOI: 10.1007/s13246-023-01351-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 10/24/2023] [Indexed: 11/10/2023]
Abstract
The TRS-483 Code of Practice (CoP) provides generic relative output correction factors, [Formula: see text], for a range of detectors and beam energies as used in small field dosimetry. In this work, the convergence of the relative output factors (ROFs) for 6 MV X-ray beams with and without flattening filters was investigated under different combinations of beam collimation and published detector correction factors. The SFD, PFD and CC04 (IBA) were used to measure ROFs of a TrueBeam STx linear accelerator with small fields collimated by the high-definition MLC, which has 2.5 and 5.0 mm projected leaves. Two configurations were used for the collimators: (1) fixed jaws at 10 × 10 cm2 and (2) with a 2 mm offset from the MLC edge, in line with the recommended geometry from IROC-H as part of their auditing program and published dataset. The [Formula: see text] factors for the three detectors were taken from the TRS483 CoP and other published works. The average differences of ROFs measured by detectors under MLC fields with fixed jaws and with 2 mm jaws offset for the 6 MV-WFF beam are 1.4% and 1.9%, respectively. Similarly, they are 2.3% and 2.4% for the 6MV-FFF beam. The relative differences between the detector-average ROFs and the corresponding IROC-H dataset are 2.0% and 3.1% for the 6 MV-WFF beam, while they are 2.4% and 3.2% for the 6MV-FFF beam at the smallest available field size of 2 × 2 cm2. For smaller field sizes, the average ROFs of the three detectors and corresponding results from Akino and Dufreneix showed the largest difference to be 6.6% and 6.2% under the 6 MV-WFF beam, while they are 3.4% and 3.6% under the 6 MV-WFF beam at the smallest field size of 0.5 × 0.5 cm2. Some well-published specific output correction factors for different small field detector types give better convergence in the calculation of the relative output factor in comparison with the generic data provided by the TRS-483 CoP. Relative output factor measurements should be performed as close as possible to the clinical settings including a combination of collimation systems, beam types and using at least three different types of small field detector for more accurate computation of the treatment planning system. The IROC-H dataset is not available for field size smaller than 2 × 2 cm2 for double checks and so that user should carefully check with other publications with the same setting.
Collapse
Affiliation(s)
- Do Duc Chi
- 108 Military Central Hospital, Hanoi, Vietnam.
- Vietnam Atomic Energy Institute, Hanoi, Vietnam.
| | | | - Robin Hill
- Department of Radiation Oncology, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, Sydney, NSW, 2050, Australia
- Arto Hardy Family Biomedical Innovation Hub, Chris O'Brien Lifehouse, Missenden Rd, Camperdown, Sydney, NSW, 2050, Australia
- Institute of Medical Physics, School of Physics, The University of Sydney, Sydney, NSW, 2006, Australia
| |
Collapse
|
2
|
Casar B, Mendez I, Gershkevitsh E, Wegener S, Jaffray D, Heaton R, Pesznyak C, Stelczer G, Bulski W, Chełminski K, Smirnov G, Antipina N, Beavis AW, Harding N, Jurković S, Hwang MS, Saiful Huq M. On dosimetric characteristics of detectors for relative dosimetry in small fields: a multicenter experimental study. Phys Med Biol 2024; 69:035009. [PMID: 38091616 DOI: 10.1088/1361-6560/ad154c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 12/13/2023] [Indexed: 01/25/2024]
Abstract
Objective. In this multicentric collaborative study, we aimed to verify whether the selected radiation detectors satisfy the requirements of TRS-483 Code of Practice for relative small field dosimetry in megavoltage photon beams used in radiotherapy, by investigating four dosimetric characteristics. Furthermore, we intended to analyze and complement the recommendations given in TRS-483.Approach. Short-term stability, dose linearity, dose-rate dependence, and leakage were determined for 17 models of detectors considered suitable for small field dosimetry. Altogether, 47 detectors were used in this study across ten institutions. Photon beams with 6 and 10 MV, with and without flattening filters, generated by Elekta Versa HDTMor Varian TrueBeamTMlinear accelerators, were used.Main results. The tolerance level of 0.1% for stability was fulfilled by 70% of the data points. For the determination of dose linearity, two methods were considered. Results from the use of a stricter method show that the guideline of 0.1% for dose linearity is not attainable for most of the detectors used in the study. Following the second approach (squared Pearson's correlation coefficientr2), it was found that 100% of the data fulfill the criteriar2> 0.999 (0.1% guideline for tolerance). Less than 50% of all data points satisfied the published tolerance of 0.1% for dose-rate dependence. Almost all data points (98.2%) satisfied the 0.1% criterion for leakage.Significance. For short-term stability (repeatability), it was found that the 0.1% guideline could not be met. Therefore, a less rigorous criterion of 0.25% is proposed. For dose linearity, our recommendation is to adopt a simple and clear methodology and to define an achievable tolerance based on the experimental data. For dose-rate dependence, a realistic criterion of 1% is proposed instead of the present 0.1%. Agreement was found with published guidelines for background signal (leakage).
Collapse
Affiliation(s)
- Božidar Casar
- Institute of Oncology Ljubljana, Ljubljana, Slovenia
- Faculty of Natural Sciences and Mathematics, University of Maribor, Slovenia
| | - Ignasi Mendez
- Institute of Oncology Ljubljana, Ljubljana, Slovenia
| | | | - Sonja Wegener
- University of Wuerzburg, Radiation Oncology, Wuerzburg, Germany
| | | | | | | | | | - Wojciech Bulski
- Maria Skłodowska-Curie National Research Institute of Oncology, Warsaw, Poland
| | | | | | | | - Andrew W Beavis
- Hull University Teaching Hospitals NHS Trust, Hull, United Kingdom
| | - Nicholas Harding
- Hull University Teaching Hospitals NHS Trust, Hull, United Kingdom
| | - Slaven Jurković
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
- Faculty of Medicine, University of Rijeka, Croatia
| | - Min-Sig Hwang
- University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, PA, United States of America
| | - M Saiful Huq
- Department of Radiation Oncology, Division of Medical Physics, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, PA, United States of America
| |
Collapse
|
3
|
Kandasamy K, Samuel EJJ. Dosimetric Evaluation of Semiflex Three-dimensional Chamber under Unflatten Beam in Comparison among Different Detectors. J Med Phys 2024; 49:84-94. [PMID: 38828067 PMCID: PMC11141746 DOI: 10.4103/jmp.jmp_115_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 02/22/2024] [Accepted: 02/22/2024] [Indexed: 06/05/2024] Open
Abstract
Purpose The goal of this study is to investigate the dosimetric properties of a Semiflex three-dimensional (3D) chamber in an unflatten beam and compare its data from a small to a large field flattening filter-free (FFF) beam with different radiation detectors. Methods The sensitivity, linearity, reproducibility, dose rate dependency, and energy dependence of a Semiflex 3D detector in flattening filter and filter-free beam were fully investigated. The minimum radiation observed field widths for all detectors were calculated using lateral electronic charged particle equilibrium to investigate dosimetric characteristics such as percentage depth doses (PDDs), profiles, and output factors (OPFs) for Semiflex 3D detector under 6FFF Beam. The Semiflex 3D measured data were compared to that of other detectors employed in this study. Results The ion chamber has a dosage linearity deviation of +1.2% for <10 MU, a dose-rate dependency deviation of +0.5%, and significantly poorer sensitivity due to its small volume. There is a difference in field sizes between manufacturer specs and derived field sizes. The measured PDD, profiles, and OPFs of the Semiflex 3D chamber were within 1% of each other for all square field sizes set under linac for the 6FFF beam. Conclusion It was discovered to be an appropriate detector for relative dose measurements for 6 FFF beams with higher dose rates for field sizes more than or equal to 3 cm × 3 cm.
Collapse
Affiliation(s)
- Kanakavel Kandasamy
- Department of Physics, School of Advanced Sciences, VIT University, Vellore, Tamil Nadu, India
| | | |
Collapse
|
4
|
Neupane T, Shang C, Kassel M, Muhammad W, Leventouri T, Williams TR. Viability of the virtual cone technique using a fixed small multi-leaf collimator field for stereotactic radiosurgery of trigeminal neuralgia. J Appl Clin Med Phys 2023; 24:e14148. [PMID: 37722766 PMCID: PMC10691631 DOI: 10.1002/acm2.14148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 08/04/2023] [Accepted: 08/20/2023] [Indexed: 09/20/2023] Open
Abstract
Dosimetric uncertainties in very small (≤1.5 × 1.5 cm2 ) photon fields are remarkably higher, which undermines the validity of the virtual cone (VC) technique with a diminutive and variable MLC fields. We evaluate the accuracy and reproducibility of the VC method with a very small, fixed MLC field setting, called a fixed virtual cone (fVC), for small target radiosurgery such as trigeminal neuralgia (TGN). The fVC is characterized by 0.5 cm x 0.5 cm high-definition (HD) MLC field of 10MV FFF beam defined at 100 cm SAD, while backup jaws are positioned at 1.5 cm x 1.5 cm. A spherical dose distribution equivalent to 5 mm (diameter) physical cone was generated using 10-14 non-coplanar, partial arcs. Dosimetric accuracy was validated using SRS diode (PTW 60018), SRS MapCHECK (SNC) measurements. As a quality assurance measure, 10 treatment plans (SRS) for TGN, consisting of various arc ranges at different collimator angles were analyzed using 6 MV FFF and 10 MV FFF beams, including a field-by-field study (n = 130 fields). Dose outputs were compared between the Eclipse TPS and measurements (SRS MapCHECK). Moreover, dosimetric changes in the field defining fVC, prompted by a minute (± 0.5-1.0 mm) leaf shift, was examined among TPS, diode measurements, and Monte Carlo (MC) simulations. The beam model for fVC was validated (≤3% difference) using SRS MapCHECK based absolute dose measurements. The equivalent diameters of the 50% isodose distribution were found comparable to that of a 5 mm cone. Additionally, the comparison of field output factors, dose per MU between the TPS and SRS diode measurements using the fVC field, including ± 1 mm leaf shift, yielded average discrepancies within 5.5% and 3.5% for 6 MV FFF and 10 MV FFF beams, respectively. Overall, the fVC method is a credible alternative to the physical cone (5 mm) that can be applied in routine radiosurgical treatment of TGN.
Collapse
Affiliation(s)
- Taindra Neupane
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Charles Shang
- RSOSouth Florida Proton Therapy InstituteDelray BeachFloridaUSA
| | - Maxwell Kassel
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Wazir Muhammad
- Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Theodora Leventouri
- Center for Biological and Materials Physics (CBAMP)Department of PhysicsFlorida Atlantic UniversityBoca RatonFloridaUSA
| | - Timothy R. Williams
- Medical DirectorSouth Florida Proton Therapy InstituteDelray BeachFloridaUSA
| |
Collapse
|
5
|
Knill C, Sandhu R, Loughery B, Lin L, Halford R, Drake D, Snyder M. Commissioning and validation of a Monte Carlo algorithm for spine stereotactic radiosurgery. J Appl Clin Med Phys 2023; 24:e14092. [PMID: 37431696 PMCID: PMC10647963 DOI: 10.1002/acm2.14092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 06/12/2023] [Accepted: 06/15/2023] [Indexed: 07/12/2023] Open
Abstract
PURPOSE A 6FFF Monte Carlo (MC) dose calculation algorithm was commissioned for spine stereotactic radiosurgery (SRS). Model generation, validation, and ensuing model tuning are presented. METHODS The model was generated using in-air and in-water commissioning measurements of field sizes between 10 and 400 mm2 . Commissioning measurements were compared to simulated water tank MC calculations to validate output factors, percent depth doses (PDDs), profile sizes and penumbras. Previously treated Spine SRS patients were re-optimized with the MC model to achieve clinically acceptable plans. Resulting plans were calculated on the StereoPHAN phantom and subsequently delivered to the microDiamond and SRSMapcheck to verify calculated dose accuracy. Model tuning was performed by adjusting the model's light field offset (LO) distance between physical and radiological positions of the MLCs, to improve field size and StereoPHAN calculation accuracy. Following tuning, plans were generated and delivered to an anthropomorphic 3D-printed spine phantom featuring realistic bone anatomy, to validate heterogeneity corrections. Finally, plans were validated using polymer gel (VIPAR based formulation) measurements. RESULTS Compared to open field measurements, MC calculated output factors and PDDs were within 2%, profile penumbra widths were within 1 mm, and field sizes were within 0.5 mm. Calculated point dose measurements in the StereoPHAN were within 0.26% ± 0.93% and -0.10% ± 1.37% for targets and spinal canals, respectively. Average SRSMapcheck per-plan pass rates using a 2%/2 mm/10% threshold relative gamma analysis was 99.1% ± 0.89%. Adjusting LOs improved open field and patient-specific dosimetric agreement. Anthropomorphic phantom measurements were within -1.29% ± 1.00% and 0.27% ± 1.36% of MC calculated for the vertebral body (target) and spinal canal, respectively. VIPAR gel measurements confirmed good dosimetric agreement near the target-spine junction. CONCLUSION Validation of a MC algorithm for simple fields and complex SRS spine deliveries in homogeneous and heterogeneous phantoms has been performed. The MC algorithm has been released for clinical use.
Collapse
Affiliation(s)
- Cory Knill
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Raminder Sandhu
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Brian Loughery
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Lifeng Lin
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Robert Halford
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Doug Drake
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| | - Michael Snyder
- Department of Radiation OncologyCorewell Health William Beaumont University HospitalRoyal OakMichiganUSA
| |
Collapse
|
6
|
Azhar D, Gul A, Javid MA, Hussain MM, Shehzadi NN. Evaluation of scanning resolution, detector choice and detector orientation to be used for accurate and time-efficient commissioning of a 6MV clinical linear accelerator. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2023; 62:83-96. [PMID: 36520198 DOI: 10.1007/s00411-022-01008-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Accepted: 12/03/2022] [Indexed: 06/17/2023]
Abstract
The present study is aimed at exploring different scanning parameters, detectors and their orientations for time-efficient and accurate commissioning of a 6 MV clinical linear accelerator (LINAC). Beam profiles and percentage depth dose (PDD) curves were measured with a PTW dosimetry diode, a PTW Semiflex and a PinPoint ion chamber in different orientations. To acquire beam data, equidistant (step size of 0.5 mm, 1 mm, 2 mm and 3 mm) and fanline (step size of 2-0.5 mm, 2-1 mm, 3-0.5 mm and 3-1 mm) scanning modes were employed and data measurement time was recorded. Scan time per measurement point was also varied (0.2 s, 0.5 s and 1.0 s) to investigate its effect on the accuracy and acquisition time of beam data. Accuracy of the measured data was analyzed on the basis of the variation between measured data and data modeled by a treatment planning system. Beam profiles (particularly in penumbra region) were found to be sensitive to variation in scanning resolution and showed an improved accuracy with decrease in step size, while PDD curves were affected negligibly. The accuracy of beam data obtained with the PTW dosimetry diode and the PinPoint ion chamber was higher than those obtained with the PTW Semiflex ion chamber for small fields (2 × 2 cm2 and 3 × 3 cm2). However, the response of the PTW diode and the PinPoint ion chamber was significantly indifferent in these fields. Furthermore, axial orientation of the PTW Semiflex ion chamber improved accuracy of profiles and PDDs as compared to radial orientation, while such a difference was not significant for the PinPoint ion chamber. It is concluded that a scan time of 0.2 s/point with a fanline scanning resolution of 2-1 mm for beam profiles and 3 mm for PDDs are most favorable in terms of accuracy and time efficiency. For small fields (2 × 2 cm2 and 3 × 3 cm2), a PinPoint ion chamber in radial orientation or a dosimetry diode in axial orientation are recommended for both beam profiles and PDDs. If a PinPoint ion chamber and a PTW dosimetry diode are not available, a Semiflex ion chamber in axial orientation may be used for small fields.
Collapse
Affiliation(s)
- Deeba Azhar
- Department of Basic Sciences, University of Engineering and Technology, Taxila, 47080, Pakistan
| | - Attia Gul
- Institute of Nuclear Medicine, Oncology and Radiotherapy (INOR), Abbottabad, 22010, Pakistan.
| | - Muhamad Arshad Javid
- Institute of Physics, Islamia University of Bahawalpur, Bahawalpur, 63100, Pakistan
| | | | | |
Collapse
|
7
|
Small-field dosimetry with detector-specific output correction factor for single-isocenter stereotactic radiotherapy of single and multiple brain metastases. Radiol Phys Technol 2023; 16:10-19. [PMID: 36272022 DOI: 10.1007/s12194-022-00684-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 10/16/2022] [Accepted: 10/18/2022] [Indexed: 10/24/2022]
Abstract
Recently, the International Atomic Energy Agency and the American Association of Physicists in Medicine reported correction factors (CFs) for detector-response variation considering the uncertainty in detector readings in small-field dosimetry. In this study, the effect of CFs on small-field dosimetry measurements was evaluated for single-isocenter stereotactic radiotherapy for brain metastases. The output factors (OPFs) were measured with and without CFs in a water-equivalent sphere phantom using TrueBeam with a flattening-filter-free energy of 10 MV. Five detectors were used in a perpendicular orientation: CC01, 3D pinpoint ionization chambers, unshielded SFD detector, shielded EDGE detector, and microDiamond detector. First, the square-field sizes were set to 5-100 mm using a multi-leaf collimator (MLC) field. The OPFs were evaluated in the presence and absence of CFs. Second, single-isocenter stereotactic irradiation was performed on 22 brain metastases in 15 patients following dynamic conformal arc (DCA) treatment. The equivalent field size was calculated using the MLC aperture for each planning target volume. For the OPFs, the mean deviations from the median of the doses measured with detectors other than the CC01 for square-field sizes larger than 10 mm were within ± 4.3% of the median without CFs, and ± 3.3% with CFs. For DCA plans, the deviations without and with CFs were - 2.3 ± 1.9% and - 4.8 ± 2.4% for CC01, - 1.1 ± 3.0% and 1.0 ± 1.6% for 3D pinpoint, 8.8 ± 3.0% and 2.9 ± 2.8% for SFD, - 3.1 ± 3.0% and - 13.5 ± 4.0% for EDGE, and 8.9 ± 2.1% and 0.8 ± 1.9% for microDiamond. This feasibility study confirmed that the deviation of the detectors can be reduced using an appropriate detector with CFs.
Collapse
|
8
|
Hayashi N, Kurata S, Saito Y, Ogawa S, Yasui K. Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy. Radiol Phys Technol 2022; 15:409-416. [PMID: 36261754 DOI: 10.1007/s12194-022-00683-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 10/04/2022] [Accepted: 10/05/2022] [Indexed: 10/24/2022]
Abstract
In single-isocenter multiple-target stereotactic radiotherapy (SIMT-SRT), it is difficult to evaluate both the geometrical accuracy and absorbed dose measurement when irradiating off-isocenter targets. This study aimed to develop a simple quality assurance (QA) method to evaluate off-isocenter irradiation position accuracy in SIMT-SRT and compare its feasibility with that of a commercial device. First, we created two types of inserts and metallic balls with a diameter of 5 mm to be inserted into a commercially available phantom (SIMT phantom). Second, we developed a dedicated analysis software using Python for the Winston-Lutz test (WLT). Third, an image processing software, including the filtered back-projection algorithm, was developed to analyze the images obtained using an electronic portal imaging device (EPID). Fourth, the feasibility of our method was evaluated by comparing it with the results of WLT using two commercially available phantoms: WL-QA and MultiMet-WL cubes. Notably, 92% of the results in one-dimensional deviations were within 0.26 mm (EPID pixel width). The correlation coefficients were 0.52, 0.92, and 0.96 in the left-right, superior-inferior, and anterior-posterior directions, respectively. In the WLT, a maximum two-dimensional deviation of 0.70 mm was detected in our method, while the deviation in the other method was within 0.5 mm. The advantage of our method is that it can evaluate the geometrical accuracy at any gantry angle during dynamic rotation irradiation using a filtered back-projection algorithm, even if the target is located off the isocenter. Our method can perform WLT at arbitrary positions and is suitable for the QA of dynamic rotation irradiation using an EPID.
Collapse
Affiliation(s)
- Naoki Hayashi
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
| | - Shun Kurata
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.,Department of Radiology, Kindai University Hospital, Osakasayama, Osaka, Japan
| | - Yasunori Saito
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.,Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan
| | - Shuta Ogawa
- Department of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan
| | - Keisuke Yasui
- School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan
| |
Collapse
|
9
|
Li X, Su FC, Sarkar V, Zhao H, Ibanez S, Kunz JN, Nelson G, Jessica Huang Y. Impact of detector selection on commissioning of Leipzig surface applicators with improving immobilization in high-dose-rate brachytherapy. Brachytherapy 2022; 21:511-519. [PMID: 35256286 DOI: 10.1016/j.brachy.2022.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 01/21/2022] [Accepted: 01/24/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE Commission and treatment setup of Leipzig surface applicators, because of the steep dose gradient and lack of robust immobilization, is challenging. We aim to improve commissioning reliability by investigating the impact of detector choice on percentage depth dose (PDD) verifications, and to enhance accuracy and reproducibility in calibration/treatment setup through a simple and novel immobilization device. METHODS AND MATERIALS PDD distributions were measured with radiochromic films, optically stimulated luminescent dosimeters (OSLDs), a diode detector, and both cylindrical and parallel plate ionization chambers. The films were aligned to the applicators in parallel and transverse orientations. PDD data from a benchmarking Monte Carlo (MC) study were compared with the measured results, where surface doses were acquired from extrapolation. To improve setup accuracy and reproducibility, a custom-designed immobilization prototype device was made with cost-effective materials using a 3D printer. RESULTS The measured PDD data with different detectors had an overall good agreement (<±10%). The parallel plate ionization chamber reported unreliable doses for the smallest applicator. There was no remarkable dose difference between the two film setups. The two-in-one prototype device provided a rigid immobilization and a flexible positioning of the applicator. It enhanced accuracy and reproducibility in calibration and treatment setup. CONCLUSION We recommend using radiochromic films in the transverse orientation for a reliable and efficient PDD verification. The applicator's clinical applicability has been limited by a lack of robust immobilization. We expect this economical, easy-to-use prototype device can promote the use of Leipzig applicators in surface brachytherapy.
Collapse
Affiliation(s)
- Xing Li
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT.
| | - Fan-Chi Su
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Vikren Sarkar
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Hui Zhao
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Sergio Ibanez
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Jeremy N Kunz
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Geoff Nelson
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| | - Y Jessica Huang
- Department of Radiation Oncology, University of Utah, Salt Lake City, UT
| |
Collapse
|
10
|
Lechner W, Alfonso R, Arib M, Huq MS, Ismail A, Kinhikar R, Lárraga-Gutiérrez JM, Mani KR, Maphumulo N, Sauer OA, Shoeir S, Suriyapee S, Christaki K. A multi-institutional evaluation of small field output factor determination following the recommendations of IAEA/AAPM TRS-483. Med Phys 2022; 49:5537-5550. [PMID: 35717637 PMCID: PMC9541513 DOI: 10.1002/mp.15797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 03/31/2022] [Accepted: 05/25/2022] [Indexed: 11/15/2022] Open
Abstract
Purpose The aim of this work was to test the implementation of small field dosimetry following TRS‐483 and to develop quality assurance procedures for the experimental determination of small field output factors (SFOFs). Materials and methods Twelve different centers provided SFOFs determined with various detectors. Various linac models using the beam qualities 6 MV and 10 MV with flattening filter and without flattening filter were utilized to generate square fields down to a nominal field size of 0.5 cm × 0.5 cm. The detectors were positioned at 10 cm depth in water. Depending on the local situation, the source‐to‐surface distance was either set to 90 cm or 100 cm. The SFOFs were normalized to the output of the 10 cm × 10 cm field. The spread of SFOFs measured with different detectors was investigated for each individual linac beam quality and field size. Additionally, linac‐type specific SFOF curves were determined for each beam quality and the SFOFs determined using individual detectors were compared to these curves. Example uncertainty budgets were established for a solid state detector and a micro ionization chamber. Results The spread of SFOFs for each linac and field was below 5% for all field sizes. With the exception of one linac‐type, the SFOFs of all investigated detectors agreed within 10% with the respective linac‐type SFOF curve, indicating a potential inter‐detector and inter‐linac variability. Conclusion Quality assurance on the SFOF measurements can be done by investigation of the spread of SFOFs measured with multiple detectors and by comparison to linac‐type specific SFOFs. A follow‐up of a measurement session should be conducted if the spread of SFOFs is larger than 5%, 3%, and 2% for field sizes of 0.5 cm × 0.5 cm, 1 cm × 1 cm, and field sizes larger than 2 cm × 2 cm, respectively. Additionally, deviations of measured SFOFs to the linac‐type‐curves of more than 7%, 3%, and 2% for field sizes 0.5 cm × 0.5 cm, 1 cm × 1 cm, and field sizes larger than 1 cm × 1 cm, respectively, should be followed up.
Collapse
Affiliation(s)
- Wolfgang Lechner
- Department of Radiation Oncology, Division of Medical Physics, Medical University Vienna, Vienna, 1090, Austria
| | - Rodolfo Alfonso
- Department of Nuclear Engineering, Higher Institute of Technology and Applied Sciences, University of Havana, Havana, 10400, Cuba
| | - Mehenna Arib
- King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Anas Ismail
- Protection and Safety Department, Atomic Energy Commission of Syria, Damascus, PO Box 6091, Syria
| | - Rajesh Kinhikar
- Department of Medical Physics, Tata Memorial Centre, Mumbai, India 400012 & Homi Bhabha National Institute, Mumbai, 400094, India
| | - José M Lárraga-Gutiérrez
- Laboratorio de Física-Médica, Instituto Nacional de Neurología y Neurocirugía, Insurgentes sur 3877, La Fama, Tlalpan 14269, CDMX, México
| | - Karthick Raj Mani
- Department of Radiation Oncology, United Hospital Ltd., Dhaka, 1212, Bangladesh
| | - Nkosingiphile Maphumulo
- Radiation Dosimetry Section, National Metrology Institute of South Africa, Pretoria, South Africa
| | - Otto A Sauer
- Department of Radiation Oncology, University of Würzburg, 97080, Würzburg, Germany
| | | | - Sivalee Suriyapee
- Division of Radiation Oncology, Department of Radiology, Chulalongkorn University, Bangkok, Thailand
| | | |
Collapse
|
11
|
Investigation of the effects of the step size of Geant4 electromagnetic physics on the depth dose simulation of a small field proton beam. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
12
|
López-Sánchez M, Pérez-Fernández M, Pardo E, Fandiño JM, Teijeiro A, Gómez-Fernández N, Gómez F, González-Castaño DM. Small static radiosurgery field dosimetry with small volume ionization chambers. Phys Med 2022; 97:66-72. [DOI: 10.1016/j.ejmp.2022.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 03/15/2022] [Accepted: 04/09/2022] [Indexed: 11/28/2022] Open
|
13
|
Méndez I, Casar B. A novel approach for the definition of small-field sizes using the concept of superellipse. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
14
|
Méndez I, Rovira-Escutia JJ, Casar B. A protocol for accurate radiochromic film dosimetry using Radiochromic.com. Radiol Oncol 2021; 55:369-378. [PMID: 34384012 PMCID: PMC8366735 DOI: 10.2478/raon-2021-0034] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 07/01/2021] [Indexed: 11/21/2022] Open
Abstract
BACKGROUND Radiochromic films have many applications in radiology and radiation therapy. Generally, the dosimetry system for radiochromic film dosimetry is composed of radiochromic films, flatbed scanner, and film analysis software. The purpose of this work is to present the effectiveness of a protocol for accurate radiochromic film dosimetry using Radiochromic.com as software for film analysis. MATERIALS AND METHODS Procedures for image acquisition, lot calibration, and dose calculation are explained and analyzed. Radiochromic.com enables state-of-the-art models and corrections for radiochromic film dosimetry, such as the Multigaussian model for multichannel film dosimetry, and lateral, inter-scan, and re-calibration corrections of the response. RESULTS The protocol presented here provides accurate dose results by mitigating the sources of uncertainty that affect radiochromic film dosimetry. CONCLUSIONS Appropriate procedures for film and scanner handling in combination with Radiochromic.com as software for film analysis make easy and accurate radiochromic film dosimetry feasible.
Collapse
Affiliation(s)
- Ignasi Méndez
- Department for dosimetry and quality of radiological procedures, Institute of Oncology Ljubljana, Ljubljana, Slovenia
| | | | - Bozidar Casar
- Department for dosimetry and quality of radiological procedures, Institute of Oncology Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
15
|
Msimang ZLM, Van Der Merwe D, Maphumulo N. Effect of Three-Dimensional Detector Orientation on Small-Field Output Factors. J Med Phys 2021; 45:256-260. [PMID: 33953502 PMCID: PMC8074723 DOI: 10.4103/jmp.jmp_50_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 01/04/2021] [Accepted: 01/04/2021] [Indexed: 11/04/2022] Open
Abstract
The IAEA TRS 483 has recommended that the orientation for cylindrical ionization chambers be perpendicular to the beam for small-field output factor (OF) measurements. The recommendation was based on the unavailability of field output correction factor data for measurements using parallel orientation at the time of publication. Two three-dimensional (3D) air ionization chambers were used to perform measurements in parallel and perpendicular orientations and compared to data determined using a PTW 31018. The aim of the study was to establish whether the 3D detectors behaved as spherical or cylindrical devices. From the results, it was confirmed that the PTW 31016 and PTW 31021 detectors are suitable for OF measurements in both orientations for field sizes down to an equivalent square field of 1.8 cm and 0.96 cm, respectively, using the field output correction factor data published in the IAEA TRS 483. The preferred orientation is parallel to the beam to facilitate beam profile measurements and minimize the irradiation of the chamber stem and detector cable and decrease the volume averaging factor.
Collapse
Affiliation(s)
| | - Debbie Van Der Merwe
- Department of Physics, University of the Witwatersrand, Johannesburg, South Africa
| | | |
Collapse
|
16
|
Hachemi T, Chaoui ZEA, Khoudri S. PENELOPE simulations and experiment for 6 MV clinac iX accelerator for standard and small static fields. Appl Radiat Isot 2021; 174:109749. [PMID: 33940355 DOI: 10.1016/j.apradiso.2021.109749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 03/25/2021] [Accepted: 04/23/2021] [Indexed: 11/18/2022]
Abstract
The goal of this work was to produce accurate data for use as a 'gold standard' and a valid tool for measurements in reference dosimetry for standard/small static field sizes from 0.5 × 0.5 to 10 × 10 cm2. It is based on the accuracy of the phase space files (PSFs) as a key quantity. Because the IAEA general public database provides few PSFs for the Varian iX, we simulated the head through Monte Carlo (MC) simulations and calculated validated PSFs for 12 square field sizes including seven for small static fields. The resulting dosimetric calculations allowed us to reach a good level of agreement in comparison to our relative and absolute dose measurements performed on a Varian iX in water phantom. Measured and MC calculated output factors were investigated for different detectors. Based on the TRS 483 formalism and MC (PENELOPE/penEasy), we calculated output correction factors for the unshielded Diode-E (T60017) and the PinPoint-3D (T31016) micro-chamber according to manufacturers' blueprints. Our MC results were in agreement with the recommended data; they compete with recent measurements and MC simulations and in particular the TRS 483 MC data obtained from similar simulations. Moreover, our MC results provide supplemental data in comparison to TRS 483 data in particular for the PinPoint-3D (T31016). We suggest our MC output correction factors as new datasets for future TRS compilations. The work was substantial, used different robust MC strategies depending on the scoring regions, and led in most cases to uncertainties of less than 1%.
Collapse
Affiliation(s)
- Taha Hachemi
- Physics Department, Faculty of Sciences, Laboratory of Optoelectronic and Devices, University Ferhat Abbas Sétif 1, Algeria.
| | - Zine-El-Abidine Chaoui
- Physics Department, Faculty of Sciences, Laboratory of Optoelectronic and Devices, University Ferhat Abbas Sétif 1, Algeria
| | - Saad Khoudri
- Physics Department, Faculty of Sciences, Laboratory of Optoelectronic and Devices, University Ferhat Abbas Sétif 1, Algeria; Centre de Lutte Contre le Cancer de Sétif, Algeria
| |
Collapse
|
17
|
Debnath SBC, Tonneau D, Fauquet C, Tallet A, Goncalves A, Darreon J. Dosimetric characterization of a small-scale (Zn,Cd)S:Ag inorganic scintillating detector to be used in radiotherapy. Phys Med 2021; 84:15-23. [PMID: 33813200 DOI: 10.1016/j.ejmp.2021.03.022] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 03/14/2021] [Accepted: 03/20/2021] [Indexed: 12/01/2022] Open
Abstract
PURPOSE In modern radiotherapy techniques, to ensure an accurate beam modeling process, dosimeters with high accuracy and spatial resolution are required. Therefore, this work aims to propose a simple, robust, and a small-scale fiber-integrated X-ray inorganic detector and investigate the dosimetric characteristics used in radiotherapy. METHODS The detector is based on red-emitting silver-activated zinc-cadmium sulfide (Zn,Cd)S:Ag nanoclusters and the proposed system has been tested under 6 MV photons with standard dose rate used in the patient treatment protocol. The article presents the performances of the detector in terms of dose linearity, repeatability, reproducibility, percentage depth dose distribution, and field output factor. A comparative study is shown using a microdiamond dosimeter and considering data from recent literature. RESULTS We accurately measured a small field beam profile of 0.5 × 0.5 cm2 at a spatial resolution of 100 µm using a LINAC system. The dose linearity at 400 MU/min has shown less than 0.53% and 1.10% deviations from perfect linearity for the regular and smallest field. Percentage depth dose measurement agrees with microdiamond measurements within 1.30% and 2.94%, respectively for regular to small field beams. Besides, the stem effect analysis shows a negligible contribution in the measurements for fields smaller than 3x3 cm2. This study highlights the drastic decrease of the convolution effect using a point-like detector, especially in small dimension beam characterization. Field output factor has shown a good agreement while comparing it with the microdiamond dosimeter. CONCLUSION All the results presented here anticipated that the developed detector can accurately measure delivered dose to the region of interest, claim accurate depth dose distribution hence it can be a suitable candidate for beam characterization and quality assurance of LINAC system.
Collapse
Affiliation(s)
| | - Didier Tonneau
- Aix Marseille Université, CNRS, CINaM UMR 7325, 13288 Marseille, France
| | - Carole Fauquet
- Aix Marseille Université, CNRS, CINaM UMR 7325, 13288 Marseille, France
| | - Agnes Tallet
- Institut Paoli-Calmettes, 13009 Marseille, France
| | - Anthony Goncalves
- Institut Paoli-Calmettes, 13009 Marseille, France; Aix Marseille Université, CNRS UMR 7258, INSERM UMR 1068, CRCM, 13009 Marseille, France
| | | |
Collapse
|
18
|
Gul A, Fukuda S, Mizuno H, Taku N, Kakakhel MB, Mirza SM. Feasibility study of using Stereotactic Field Diode for field output factors measurement and evaluating three new detectors for small field relative dosimetry of 6 and 10 MV photon beams. J Appl Clin Med Phys 2020; 21:23-36. [PMID: 33078544 PMCID: PMC7700919 DOI: 10.1002/acm2.13007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 06/29/2020] [Accepted: 07/10/2020] [Indexed: 11/23/2022] Open
Abstract
This study assesses the feasibility of using stereotactic field diode (SFD) as an alternate to gaf chromic films for field output factor (FF) measurement and further evaluating three new detectors for small field dosimetry. Varian 21EX linear accelerator was used to generate 6 and 10 MV beams of nominal square fields ranging from 0.5 × 0.5 cm2 to 10 × 10 cm2. One passive (EBT3 films) and five active detectors including IBA RAZOR diode(RD), SFD, RAZOR nanochamber (RNC), pinpoint chamber (PTW31023), and semiflex chamber (PTW31010) were employed. FFs were measured using films and SFD while beam profiles and percentage depth dose (PDD) distribution were acquired with active detectors. Polarity (kpol) and recombination (ks) effects of ion chambers were determined and corrected for output ratio measurement. Correction factors (CF) of RD, RNC, and PTW31023 in axial and radial orientation were also measured. Stereotactic field diode measured FFs have shown good agreement with films (with difference of <1%). RD and RNC measured beam profiles were within 3% deviation from the SFD values. Variation in kpol with field size for RNC and PTW31023 was up to 4% and 0.4% (for fields ≥ 1 × 1 cm2), respectively, while variation in ks of PTW31023 was <0.2 %. The maximum values of CF have been calculated to be 5.2%, 2.0%, 13.6%, and 25.5% for RD, RNC, PTW31023‐axial, and PTW31023‐radial respectively. This study concludes that SFD with appropriate CFs as given in TRS 483 may be used for measuring FFs as an alternate to EBT3 films. Whereas RD and RNC may be used for beam profile and PDD measurement in small fields. Considering the limit of usability of 2%, RNC may be used without CF for FF measurement in the smallfields investigated in this study.
Collapse
Affiliation(s)
- Attia Gul
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.,Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| | - Shigekazu Fukuda
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Hideyuki Mizuno
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Nakaji Taku
- QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - M Basim Kakakhel
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| | - Sikander M Mirza
- Department of Physics & Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan
| |
Collapse
|
19
|
Radojcic DS, Casar B, Rajlic D, Kolacio MS, Mendez I, Obajdin N, Debeljuh DD, Jurkovic S. Experimental validation of Monte Carlo based treatment planning system in bone density equivalent media. Radiol Oncol 2020; 54:495-504. [PMID: 32936784 PMCID: PMC7585341 DOI: 10.2478/raon-2020-0051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 07/09/2020] [Indexed: 11/20/2022] Open
Abstract
Introduction Advanced, Monte Carlo (MC) based dose calculation algorithms, determine absorbed dose as dose to medium-in-medium (Dm,m) or dose to water-in-medium (Dw,m). Some earlier studies identified the differences in the absorbed doses related to the calculation mode, especially in the bone density equivalent (BDE) media. Since the calculation algorithms built in the treatment planning systems (TPS) should be dosimetrically verified before their use, we analyzed dose differences between two calculation modes for the Elekta Monaco TPS. We compared them with experimentally determined values, aiming to define a supplement to the existing TPS verification methodology. Materials and methods In our study, we used a 6 MV photon beam from a linear accelerator. To evaluate the accuracy of the TPS calculation approaches, measurements with a Farmer type chamber in a semi-anthropomorphic phantom were compared to those obtained by two calculation options. The comparison was made for three parts of the phantom having different densities, with a focus on the BDE part. Results Measured and calculated doses were in agreement for water and lung equivalent density materials, regardless of the calculation mode. However, in the BDE part of the phantom, mean dose differences between the calculation options ranged from 5.7 to 8.3%, depending on the method used. In the BDE part of the phantom, neither of the two calculation options were consistent with experimentally determined absorbed doses. Conclusions Based on our findings, we proposed a supplement to the current methodology for the verification of commercial MC based TPS by performing additional measurements in BDE material.
Collapse
Affiliation(s)
- Djeni Smilovic Radojcic
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
- Department of Medical Physics and Biophysics, Faculty of Medicine, University of Rijeka, Rijeka, Croatia
| | - Bozidar Casar
- Department for Dosimetry and Quality of Radiological procedures, Institute of Oncology Ljubljana, Ljubljana, Slovenia
- Faculty of Mathematics and Physics, University of Ljubljana, Ljubljana, Slovenia
| | - David Rajlic
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
| | | | - Ignasi Mendez
- Department for Dosimetry and Quality of Radiological procedures, Institute of Oncology Ljubljana, Ljubljana, Slovenia
| | - Nevena Obajdin
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
| | - Dea Dundara Debeljuh
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
- General Hospital Pula, Radiology Department, Pula, Croatia
| | - Slaven Jurkovic
- Medical Physics Department, University Hospital Rijeka, Rijeka, Croatia
- Department of Medical Physics and Biophysics, Faculty of Medicine, University of Rijeka, Rijeka, Croatia
| |
Collapse
|