1
|
Smith BR, Hyer DE. The LET enhancement of energy-specific collimation in pencil beam scanning proton therapy. J Appl Clin Med Phys 2025; 26:e14477. [PMID: 39644507 PMCID: PMC11712952 DOI: 10.1002/acm2.14477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/11/2024] [Accepted: 06/18/2024] [Indexed: 12/09/2024] Open
Abstract
PURPOSE To computationally characterize the LET distribution during dynamic collimation in PBS and quantify its impact on the resultant dose distribution. METHODS Monte Carlo simulations using Geant4 were used to model the production of low-energy proton scatter produced in the collimating components of a novel PBS collimator. Custom spectral tallies were created to quantify the energy, track- and dose-averaged LET resulting from individual beamlet and composite fields simulated from a model of the IBA dedicated nozzle system. The composite dose distributions were optimized to achieve a uniform physical dose coverage of a cubical and pyramidal target, and the resulting dose-average LET distributions were calculated for uncollimated and collimated PBS deliveries and used to generate RBE-weighted dose distributions. RESULTS For collimated beamlets, the scattered proton energy fluence is strongly dependent on collimator position relative to the central axis of the beamlet. When delivering a uniform profile, the distribution of dose-average LET was nearly identical within the target and increased between 1 and2 keV / μ m $2 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm surrounding the target. Dynamic collimation resulted in larger dose-average LET changes: increasing the dose-average LET between 1 and3 keV / μ m $3 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ within 10 mm of a pyramidal target while reducing the dose-average LET outside this margin by as much as10 keV / μ m $10 \,{\rm keV}/\mathrm{\umu }\mathrm{m}$ . Biological dose distributions are improved with energy-specific collimation in reducing the lateral penumbra. CONCLUSION The presence of energy-specific collimation in PBS can lead to dose-average LET changes relative to an uncollimated delivery. In some clinical situations, the placement and application of energy-specific collimation may require additional planning considerations based on its reduction to the lateral penumbra and increase in high-dose conformity. Future applications may embody these unique dosimetric characteristics to redirect high-LET portions of a collimated proton beamlet from healthy tissues while enhancing the dose-average LET distribution within target.
Collapse
Affiliation(s)
- Blake R. Smith
- Department of Radiation OncologyUniversity of IowaIowa CityIowaUSA
| | - Daniel E. Hyer
- Department of Radiation OncologyUniversity of IowaIowa CityIowaUSA
| |
Collapse
|
2
|
Dong S, Sun J, Ming X, Weber U, Schuy C, Hu W, Sheng Y. Development of porous structure for broadening Bragg-peak in scanning carbon-ion radiotherapy: Monte Carlo simulation and experimental validation. Phys Med 2024; 120:103325. [PMID: 38493583 DOI: 10.1016/j.ejmp.2024.103325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/15/2024] [Accepted: 03/04/2024] [Indexed: 03/19/2024] Open
Abstract
PURPOSE The present study aimed to develop a porous structure with plug-ins (PSP) to broaden the Bragg peak width (BPW, defined as the distance in water between the proximal and distal 80% dose) of the carbon ion beam while maintaining a sharp distal falloff width (DFW, defined as the distance along the beam axis where the dose in water reduces from 80% to 20%). METHODS The binary voxel models of porous structure (PS) and PSP were established in the Monte Carlo code FLUKA and the corresponding physical models were manufactured by 3D printing. Both experiment and simulation were performed for evaluating the modulation capacity of PS and PSP. BPWs and DFWs derived from each integral depth dose curves were compared. Fluence homogeneity of 430 MeV/u carbon-ion beam passing through the PSP was recorded by analyzing radiochromic films at six different locations downstream the PSP in the experiment. Additionally, by changing the beam spot size and incident position on the PSP, totally 48 different carbon-ion beams were simulated and corresponding deviations of beam metrics were evaluated to test the modulating stability of PSP. RESULTS According to the measurement data, the use of PSP resulted in an average increase of 0.63 mm in BPW and a decrease of 0.74 mm in DFW compared to PS. The 2D radiation field inhomogeneities were lower than 3 % when the beam passing through a ≥ 10 cm PMMA medium. Furthermore, employing a spot size of ≥ 6 mm ensures that beam metric deviations, including BPW, DFW, and range, remain within a deviation of 0.1 mm across various incident positions. CONCLUSION The developed PSP demonstrated its capability to effectively broaden the BPW of carbon ion beams while maintaining a sharp DFW comparing to PS. The superior performance of PSP, indicates its potential for clinical use in the future.
Collapse
Affiliation(s)
- Sixue Dong
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai 201315, China; Shanghai Key Laboratory of radiation oncology(20dz2261000); Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy
| | - Jiayao Sun
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai 201315, China; Shanghai Key Laboratory of radiation oncology(20dz2261000); Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy
| | - Xue Ming
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai 201315, China; Shanghai Key Laboratory of radiation oncology(20dz2261000); Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy
| | - Uli Weber
- Biophysics GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany
| | - Christoph Schuy
- Biophysics GSI Helmholtz Center for Heavy Ion Research GmbH, Darmstadt, Germany
| | - Weigang Hu
- Shanghai Key Laboratory of radiation oncology(20dz2261000); Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, China; Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China; Shanghai Clinical Research Center for Radiation Oncology.
| | - Yinxiangzi Sheng
- Department of Medical Physics, Shanghai Proton and Heavy Ion Center, Fudan University Cancer Hospital, Shanghai 201315, China; Shanghai Key Laboratory of radiation oncology(20dz2261000); Shanghai Engineering Research Center of Proton and Heavy Ion Radiation Therapy.
| |
Collapse
|
3
|
Bennett LC, Hyer DE, Erhart K, Nelson NP, Culberson WS, Smith BR, Hill PM, Flynn RT. PETRA: A pencil beam trimming algorithm for analytical proton therapy dose calculations with the dynamic collimation system. Med Phys 2023; 50:7263-7280. [PMID: 37370239 PMCID: PMC10751389 DOI: 10.1002/mp.16559] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 05/28/2023] [Accepted: 05/30/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND The Dynamic Collimation System (DCS) has been shown to produce superior treatment plans to uncollimated pencil beam scanning (PBS) proton therapy using an in-house treatment planning system (TPS) designed for research. Clinical implementation of the DCS requires the development and benchmarking of a rigorous dose calculation algorithm that accounts for pencil beam trimming, performs monitor unit calculations to produce deliverable plans at all beam energies, and is ideally implemented with a commercially available TPS. PURPOSE To present an analytical Pencil bEam TRimming Algorithm (PETRA) for the DCS, with and without its range shifter, implemented in the Astroid TPS (.decimal, Sanford, Florida, USA). MATERIALS PETRA was derived by generalizing an existing pencil beam dose calculation model to account for the DCS-specific effects of lateral penumbra blurring due to the nickel trimmers in two different planes, integral depth dose variation due to the trimming process, and the presence and absence of the range shifter. Tuning parameters were introduced to enable agreement between PETRA and a measurement-validated Dynamic Collimation Monte Carlo (DCMC) model of the Miami Cancer Institute's IBA Proteus Plus system equipped with the DCS. Trimmer position, spot position, beam energy, and the presence or absence of a range shifter were all used as variables for the characterization of the model. The model was calibrated for pencil beam monitor unit calculations using procedures specified by International Atomic Energy Agency Technical Report Series 398 (IAEA TRS-398). RESULTS The integral depth dose curves (IDDs) for energies between 70 MeV and 160 MeV among all simulated trimmer combinations, with and without the ranger shifter, agreed between PETRA and DCMC at the 1%/1 mm 1-D gamma criteria for 99.99% of points. For lateral dose profiles, the median 2-D gamma pass rate for all profiles at 1.5%/1.5 mm was 99.99% at the water phantom surface, plateau, and Bragg peak depths without the range shifter and at the surface and Bragg peak depths with the range shifter. The minimum 1.5%/1.5 mm gamma pass rates for the 2-D profiles at the water phantom surface without and with the range shifter were 98.02% and 97.91%, respectively, and, at the Bragg peak, the minimum pass rates were 97.80% and 97.5%, respectively. CONCLUSION The PETRA model for DCS dose calculations was successfully defined and benchmarked for use in a commercially available TPS.
Collapse
Affiliation(s)
- Laura C. Bennett
- Roy J. Carver Department of Biomedical Engineering, University of Iowa, 5601 Seamans Center for the Engineering Arts and Sciences, Iowa City, IA, 52242, USA
| | - Daniel E. Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Kevin Erhart
- .decimal LLC, 121 Central Park Pl, Sanford, FL, 32771, USA
| | - Nicholas P. Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin, 1111 Highland Avenue, Madison, WI, 53705, USA
| | - Wesley S. Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin, 1111 Highland Avenue, Madison, WI, 53705, USA
| | - Blake R. Smith
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| | - Patrick M. Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin, 600 Highland Avenue, Madison, WI, 53792, USA
| | - Ryan T. Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, USA
| |
Collapse
|
4
|
Nelson NP, Culberson WS, Hyer DE, Geoghegan TJ, Patwardhan KA, Smith BR, Flynn RT, Gutiérrez AN, Boland T, Hill PM. Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy. Biomed Phys Eng Express 2023; 9:10.1088/2057-1976/ad02ff. [PMID: 37832529 PMCID: PMC11128250 DOI: 10.1088/2057-1976/ad02ff] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/13/2023] [Indexed: 10/15/2023]
Abstract
Objective.To integrate a Dynamic Collimation System (DCS) into a pencil beam scanning (PBS) proton therapy system and validate its dosimetric impact.Approach.Uncollimated and collimated treatment fields were developed for clinically relevant targets using an in-house treatment plan optimizer and an experimentally validated Monte Carlo model of the DCS and IBA dedicated nozzle (DN) system. The dose reduction induced by the DCS was quantified by calculating the mean dose in 10- and 30-mm two-dimensional rinds surrounding the target. A select number of plans were then used to experimentally validate the mechanical integration of the DCS and beam scanning controller system through measurements with the MatriXX-PT ionization chamber array and EBT3 film. Absolute doses were verified at the central axis at various depths using the IBA MatriXX-PT and PPC05 ionization chamber.Main results.Simulations demonstrated a maximum mean dose reduction of 12% for the 10 mm rind region and 45% for the 30 mm rind region when utilizing the DCS. Excellent agreement was observed between Monte Carlo simulations, EBT3 film, and MatriXX-PT measurements, with gamma pass rates exceeding 94.9% for all tested plans at the 3%/2 mm criterion. Absolute central axis doses showed an average verification difference of 1.4% between Monte Carlo and MatriXX-PT/PPC05 measurements.Significance.We have successfully dosimetrically validated the delivery of dynamically collimated proton therapy for clinically relevant delivery patterns and dose distributions with the DCS. Monte Carlo simulations were employed to assess dose reductions and treatment planning considerations associated with the DCS.
Collapse
Affiliation(s)
- Nicholas P Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America
| | - Wesley S Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America
| | - Daniel E Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Theodore J Geoghegan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Kaustubh A Patwardhan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Blake R Smith
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Ryan T Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Alonso N Gutiérrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 331765, United States of America
| | | | - Patrick M Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin—Madison, 600 Highland Avenue, Madison, WI, 53792, United States of America
| |
Collapse
|
5
|
Geoghegan T, Patwardhan K, Ying Q, Nelson N, Yu J, Gutierrez A, Hill P, Flynn R, Hyer D. Design, testing and characterization of a proton central axis alignment device for the dynamic collimation system. Biomed Phys Eng Express 2023; 9:10.1088/2057-1976/acdad5. [PMID: 37267924 PMCID: PMC10330655 DOI: 10.1088/2057-1976/acdad5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Accepted: 06/02/2023] [Indexed: 06/04/2023]
Abstract
Objective. Proton therapy conformity has improved over the years by evolving from passive scattering to spot scanning delivery technologies with smaller proton beam spot sizes. Ancillary collimation devices, such the Dynamic Collimation System (DCS), further improves high dose conformity by sharpening the lateral penumbra. However, as spot sizes are reduced, collimator positional errors play a significant impact on the dose distributions and hence accurate collimator to radiation field alignment is critical.Approach. The purpose of this work was to develop a system to align and verify coincidence between the center of the DCS and the proton beam central axis. The Central Axis Alignment Device (CAAD) is composed of a camera and scintillating screen-based beam characterization system. Within a light-tight box, a 12.3-megapixel camera monitors a P43/Gadox scintillating screen via a 45° first-surface mirror. When a collimator trimmer of the DCS is placed in the uncalibrated center of the field, the proton radiation beam continuously scans a 7×7 cm2square field across the scintillator and collimator trimmer while a 7 s exposure is acquired. From the relative positioning of the trimmer to the radiation field, the true center of the radiation field can be calculated.Main results.The CAAD can calculate the offset between the proton beam radiation central axis and the DCS central axis within 0.054 mm accuracy and 0.075 mm reproducibility.Significance.Using the CAAD, the DCS is now able to be aligned accurately to the proton radiation beam central axis and no longer relies on an x-ray source in the gantry head which is only validated to within 1.0 mm of the proton beam.
Collapse
Affiliation(s)
- Theodore Geoghegan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Kaustubh Patwardhan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Qi Ying
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Nicholas Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America
| | - Jen Yu
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Alonso Gutierrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Patrick Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI, 53792, United States of America
| | - Ryan Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Daniel Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| |
Collapse
|
6
|
Nabha R, De Saint-Hubert M, Marichal J, Esser J, Van Hoey O, Bäumer C, Verbeek N, Struelens L, Sterpin E, Tabury K, Marek L, Granja C, Timmermann B, Vanhavere F. Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy. Phys Med Biol 2023; 68. [PMID: 36821866 DOI: 10.1088/1361-6560/acbe8d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 02/23/2023] [Indexed: 02/25/2023]
Abstract
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets.Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with publishedin silicobiophysical models to elucidate the potential biological effects of collimated and uncollimated fields.Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keVμm-1in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keVμm-1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction.Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.
Collapse
Affiliation(s)
- Racell Nabha
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.,KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| | - Marijke De Saint-Hubert
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | - Johannes Esser
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany
| | - Olivier Van Hoey
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | - Christian Bäumer
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany.,TU Dortmund University, Department of Physics, Dortmund, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany
| | - Nico Verbeek
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany
| | - Lara Struelens
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | - Edmond Sterpin
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium.,UCLouvain, Institut de Recherche Expérimentale et Clinique, MIRO Lab, Brussels, Belgium
| | - Kevin Tabury
- Radiobiology Unit, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
| | | | | | - Beate Timmermann
- West German Proton Therapy Centre Essen, Essen, Germany.,West German Cancer Center (WTZ), University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Department of Particle Therapy, University Hospital Essen, Essen, Germany
| | - Filip Vanhavere
- Radiation Protection Dosimetry and Calibration Expert Group, Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium.,KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
| |
Collapse
|
7
|
Nelson NP, Culberson WS, Hyer DE, Geoghegan TJ, Patwardhan KA, Smith BR, Flynn RT, Yu J, Gutiérrez AN, Hill PM. Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy. Phys Med Biol 2023; 68:055003. [PMID: 36706460 PMCID: PMC9940016 DOI: 10.1088/1361-6560/acb6cd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 01/27/2023] [Indexed: 01/28/2023]
Abstract
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system.Approach. Optimized single field, uniform dose treatment plans for 3 × 3 × 3 cm3target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic™ EBT3 film.Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT.Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
Collapse
Affiliation(s)
- Nicholas P Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America,Author to whom any correspondence should be addressed
| | - Wesley S Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705, United States of America
| | - Daniel E Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Theodore J Geoghegan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Kaustubh A Patwardhan
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Blake R Smith
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Ryan T Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242, United States of America
| | - Jen Yu
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Alonso N Gutiérrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176, United States of America
| | - Patrick M Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin—Madison, 600 Highland Avenue, Madison, WI, 53792, United States of America
| |
Collapse
|
8
|
Nelson NP, Culberson WS, Hyer DE, Smith BR, Flynn RT, Hill PM. Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy. Biomed Phys Eng Express 2022; 8:10.1088/2057-1976/ac525f. [PMID: 35130520 PMCID: PMC8917788 DOI: 10.1088/2057-1976/ac525f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 02/07/2022] [Indexed: 11/12/2022]
Abstract
Purpose. The Dynamic Collimation System (DCS) is an energy layer-specific collimation device designed to reduce the lateral penumbra in pencil beam scanning proton therapy. The DCS consists of two pairs of nickel trimmers that rapidly and independently move and rotate to intercept the scanning proton beam and an integrated range shifter to treat targets less than 4 cm deep. This work examines the validity of a single aperture approximation to model the DCS, a commonly used approximation in commercial treatment planning systems, as well as higher-order aperture-based approximations for modeling DCS-collimated dose distributions.Methods. An experimentally validated TOPAS/Geant4-based Monte Carlo model of the DCS integrated with a beam model of the IBA pencil beam scanning dedicated nozzle was used to simulate DCS- and aperture-collimated 100 MeV beamlets and composite treatment plans. The DCS was represented by three different aperture approximations: a single aperture placed halfway between the upper and lower trimmer planes, two apertures located at the upper and lower trimmer planes, and four apertures, located at both the upstream and downstream faces of each pair of trimmers. Line profiles and three-dimensional regions of interest were used to evaluate the validity and limitations of the aperture approximations investigated.Results. For pencil beams without a range shifter, minimal differences were observed between the DCS and single aperture approximation. For range shifted beamlets, the single aperture approximation yielded wider penumbra widths (up to 18%) in the X-direction and sharper widths (up to 9.4%) in the Y-direction. For the example treatment plan, the root-mean-square errors (RMSEs) in an overall three-dimensional region of interest were 1.7%, 1.3%, and 1.7% for the single aperture, two aperture, and four aperture models, respectively. If the region of interest only encompasses the lateral edges outside of the target, the resulting RMSEs were 1.7%, 1.1%, and 0.5% single aperture, two aperture, and four aperture models, respectively.Conclusions. Monte Carlo simulations of the DCS demonstrated that a single aperture approximation is sufficient for modeling pristine fields at the Bragg depth while range shifted fields require a higher-order aperture approximation. For the treatment plan considered, the double aperture model performed the best overall, however, the four-aperture model most accurately modeled the lateral field edges at the expense of increased dose differences proximal to and within the target.
Collapse
Affiliation(s)
- Nicholas P. Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705
| | - Wesley S. Culberson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin—Madison, 1111 Highland Avenue, Madison, WI, 53705
| | - Daniel E. Hyer
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242
| | - Blake R. Smith
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242
| | - Ryan T. Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA, 52242
| | - Patrick M. Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin—Madison, 600 Highland Avenue, Madison, WI, 53792
| |
Collapse
|
9
|
Smith BR, M S NPN, M S TJG, M S KAP, Hill PM, Yu J, Gutiérrez AN, Md BGA, Hyer DE. The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy. Med Phys 2022; 49:2684-2698. [PMID: 35120278 PMCID: PMC9007854 DOI: 10.1002/mp.15523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 11/22/2021] [Accepted: 01/23/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The radiobiological benefits afforded by spatially fractionated (GRID) radiation therapy pairs well with the dosimetric advantages of proton therapy. Inspired by the emergence of energy-layer specific collimators in pencil beam scanning (PBS), this work investigates how the spot spacing and collimation can be optimized to maximize the therapeutic gains of a GRID treatment while demonstrating the integration of a dynamic collimation system (DCS) within a commercial beam line to deliver GRID treatments and experimentally benchmark Monte Carlo calculation methods. METHODS GRID profiles were experimentally benchmarked using a clinical DCS prototype that was mounted to the nozzle of the IBA Dedicated Nozzle system. Integral depth dose (IDD) curves and lateral profiles were measured for uncollimated and GRID-collimated beamlets. A library of collimated GRID dose distributions were simulated by placing beamlets within a specified uniform grid and weighting the beamlets to achieve a volume-averaged tumor cell survival equivalent to an open field delivery. The healthy tissue sparing afforded by the GRID distribution was then estimated across a range of spot spacings and collimation widths, which were later optimized based on the radiosensitivity of the tumor cell line and the nominal spot size of the PBS system. This was accomplished by using validated models of the IBA Universal and Dedicated nozzles. RESULTS Excellent agreement was observed between the measured and simulated profiles. The IDDs matched above 98.7% when analyzed using a 1%/1 mm gamma criteria with some minor deviation observed near the Bragg peak for higher beamlet energies. Lateral profile distributions predicted using Monte Carlo methods agreed well with the measured profiles; a gamma passing rate of 95% or higher was observed for all in-depth profiles examined using a 3%/2 mm criteria. Additional collimation was shown to improve PBS GRID treatments by sharpening the lateral penumbra of the beamlets but creates a tradeoff between enhancing the valley-to-peak ratio of the GRID delivery and the dose-volume effect. The optimal collimation width and spot spacing changed as a function of the tumor cell radiosensitivity, dose, and spot size. In general, a spot spacing below 2.0 cm with a collimation less than 1.0 cm provided a superior dose distribution among the specific cases studied. CONCLUSIONS The ability to customize a GRID dose distribution using different collimation sizes and spot spacings is a useful advantage, especially to maximize the overall therapeutic benefit. In this regard, the capabilities of the DCS, and perhaps alternative dynamic collimators, can be used to enhance GRID treatments. Physical dose models calculated using Monte Carlo methods were experimentally benchmarked in water and were found to accurately predict the respective dose distributions of uncollimated and DCS-collimated GRID profiles. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Blake R Smith
- Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, 52242 Iowa
| | - Nicholas P Nelson M S
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, 53705
| | | | | | - Patrick M Hill
- Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin-Madison, 600 Highland Avenue, Madison, WI, 53792
| | - Jen Yu
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176
| | - Alonso N Gutiérrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, 8900 N. Kendall Drive, Miami, FL, 33176
| | - Bryan G Allen Md
- Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, 52242 Iowa
| | - Daniel E Hyer
- Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, 52242 Iowa
| |
Collapse
|
10
|
Geoghegan T, Patwardhan K, Nelson N, Hill P, Flynn R, Smith B, Hyer D. Mechanical Characterization and Validation of the Dynamic Collimation System Prototype for Proton Radiotherapy. J Med Device 2022; 16:021013. [DOI: 10.1115/1.4053722] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 01/05/2022] [Indexed: 11/08/2022] Open
Abstract
Abstract
Radiation therapy is integral to cancer treatments for more than half of patients. Pencil beam scanning (PBS) proton therapy is the latest radiation therapy technology that uses a beam of protons that are magnetically steered and delivered to the tumor. One of the limiting factors of PBS accuracy is the beam cross-sectional size, similar to how a painter is only as accurate as the size of their brush allows. To address this, collimators can be used to shape the beam along the tumor edge to minimize the dose spread outside of the tumor. Under development is a dynamic collimation system (DCS) that uses two pairs of nickel trimmers that collimate the beam at the tumor periphery, limiting dose from spilling into healthy tissue. Herein, we establish the dosimetric and mechanical acceptance criteria for the DCS based on a functioning prototype and Monte Carlo methods, characterize the mechanical accuracy of the prototype, and validate that the acceptance criteria are met. From Monte Carlo simulations, we found that the trimmers must be positioned within ±0.5mm and ±1.0° for the dose distributions to pass our gamma analysis. We characterized the trimmer positioners at jerk values up to 400 m/s3 and validated their accuracy to 50 µm. We measured and validated the rotational trimmer accuracy to ±0.5° with a FARO® ScanArm. Lastly, we calculated time penalties associated with the DCS and found that the additional time required to treat one field using the DCS varied from 25-52 seconds.
Collapse
Affiliation(s)
- Theodore Geoghegan
- Department of Radiation Oncology, University of Iowa Hospitals & Clinics, 200 Hawkins Dr., Iowa City, IA 52242
| | - Kaustubh Patwardhan
- Department of Radiation Oncology, University of Iowa Hospitals & Clinics, 200 Hawkins Dr., Iowa City, IA 52242
| | - Nicholas Nelson
- Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, WI, 53705 USA
| | - Patrick Hill
- Department of Human Oncology, School of Medicine & Public Health, University of Wisconsin - Madison, 600 Highland Avenue, K4/B82, Madison, WI 53792
| | - Ryan Flynn
- Department of Radiation Oncology, University of Iowa Hospitals & Clinics, 200 Hawkins Dr., Iowa City, IA 52242
| | - Blake Smith
- Department of Radiation Oncology, University of Iowa Hospitals & Clinics, 200 Hawkins Dr., Iowa City, IA 52242
| | - Daniel Hyer
- Department of Radiation Oncology, University of Iowa Hospitals & Clinics, 200 Hawkins Dr., Iowa City, IA 52242
| |
Collapse
|