1
|
Henningsson M, Zahr RA, Dyer A, Greil GF, Burkhardt B, Tandon A, Hussain T. Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease. J Cardiovasc Magn Reson 2018; 20:76. [PMID: 30474554 PMCID: PMC6260764 DOI: 10.1186/s12968-018-0508-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 11/14/2018] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.
Collapse
Affiliation(s)
- Markus Henningsson
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Riad Abou Zahr
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Adrian Dyer
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Gerald F. Greil
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Barbara Burkhardt
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Animesh Tandon
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| | - Tarique Hussain
- Departments of Pediatrics and Radiology, University of Texas Southwestern/Children’s Health, Dallas, TX USA
| |
Collapse
|
2
|
Meisel CL, Bainbridge P, Mitsouras D, Wong JY. Targeted Nanoparticle Binding to Hydroxyapatite in a High Serum Environment for Early Detection of Heart Disease. ACS APPLIED NANO MATERIALS 2018; 1:4927-4939. [PMID: 31867573 PMCID: PMC6924636 DOI: 10.1021/acsanm.8b01099] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The impact of the protein-rich in vivo environment on targeted binding of functionalized nanoparticles has been an active field of research over the past several years. Current research aims at better understanding the nature of the protein corona and how it may be possible for targeted binding to occur even in the presence of serum. Much of the current research focuses on nanoparticles targeted to particular cell receptors or features with the aim of cellular uptake. However, similar research has not been performed on nanoparticles that are targeted to non-protein disease features, such as hydroxyapatite (HA). HA is a crystalline calcium-phosphate mineral that is present in large quantities in bone, and in smaller quantities in diseased cardiovascular tissue in cases of atherosclerosis or various stenoses. Our work aims to gain a better understanding of the behavior of PEGylated, peptide-coated superparamagnetic iron oxide nanoparticles (SPIONs) in a biologically-relevant high-protein environment (50% serum). We first determined that specific binding to HA occurs at significantly higher rates than non-specific binding in the absence of serum protein. We then examined nanoparticle interactions with serum proteins, including determination of the relative quantities of protein in the hard vs. soft protein corona. Finally, we examined specific and non-specific binding of targeted SPIONs in 50% serum, and determined that targeted binding may still occur with significant (p < 0.05) selectivity. We hypothesize that this may be because the nature of the binding interactions between the peptides and the HA are, by definition, less specific than the protein-protein interactions required for nanoparticles to bind to specific cells or cell features. These results suggest that these targeted SPIONs may be further developed for use in early detection of heart diseases such as atherosclerosis and aortic stenosis.
Collapse
Affiliation(s)
- Cari L. Meisel
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215
| | - Polly Bainbridge
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215
| | - Dimitrios Mitsouras
- Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02215
- Department of Biochemistry Microbiology and Immunology, The University of Ottawa, Faculty of Medicine, 501 Smyth Rd., Ottowa, ON K1H 3L7 Canada
| | - Joyce Y. Wong
- Department of Biomedical Engineering, Boston University, 44 Cummington Mall, Boston, MA 02215
| |
Collapse
|
3
|
Mitsouras D, Tao M, de Vries MR, Trocha K, Miranda OR, Vemula PK, Ding K, Imanzadeh A, Schoen FJ, Karp JM, Ozaki CK, Rybicki FJ. Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts. Acta Radiol 2018; 59:1074-1081. [PMID: 29378421 DOI: 10.1177/0284185117753656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background Non-invasive monitoring of autologous vein graft (VG) bypass grafts is largely limited to detecting late luminal narrowing. Although magnetic resonance imaging (MRI) delineates vein graft intima, media, and adventitia, which may detect early failure, the scan time required to achieve sufficient resolution is at present impractical. Purpose To study VG visualization enhancement in vivo and delineate whether a covalently attached MRI contrast agent would enable quicker longitudinal imaging of the VG wall. Material and Methods Sixteen 12-week-old male C57BL/6J mice underwent carotid interposition vein grafting. The inferior vena cava of nine donor mice was treated with a gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA)-based contrast agent, with control VGs labeled with a vehicle. T1-weighted (T1W) MRI was performed serially at postoperative weeks 1, 4, 12, and 20. A portion of animals was sacrificed for histopathology following each imaging time point. Results MRI signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher for treated VGs in the first three time points (1.73 × higher SNR, P = 0.0006, and 5.83 × higher CNR at the first time point, P = 0.0006). However, MRI signal enhancement decreased consistently in the study period, to 1.29 × higher SNR and 2.64 × higher CNR, by the final time point. There were no apparent differences in graft morphometric analyses in Masson's trichrome-stained sections. Conclusion A MRI contrast agent that binds covalently to the VG wall provides significant increase in T1W MRI signal with no observed adverse effects in a mouse model. Further optimization of the contrast agent to enhance its durability is required.
Collapse
Affiliation(s)
- Dimitrios Mitsouras
- Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women’s Hospital, Boston, MA, USA
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, ON, Canada
| | - Ming Tao
- Department of Surgery, Brigham and Women’s Hospital, Boston, MA, USA
| | - Margreet R de Vries
- Department of Surgery, Einthoven Laboratory for Experimental Vascular Medicine, Leiden University Medical Center, Leiden, The Netherlands
| | - Kaspar Trocha
- Department of Surgery, Brigham and Women’s Hospital, Boston, MA, USA
| | - Oscar R Miranda
- Harvard Stem Cell Institute, Harvard University, Boston, MA, USA
- Harvard-MIT Division of Health Science and Technology, Department of Medicine, Brigham and Women’s Hospital, Boston, MA, USA
| | - Praveen Kumar Vemula
- Harvard Stem Cell Institute, Harvard University, Boston, MA, USA
- Harvard-MIT Division of Health Science and Technology, Department of Medicine, Brigham and Women’s Hospital, Boston, MA, USA
| | - Kui Ding
- Department of Surgery, Brigham and Women’s Hospital, Boston, MA, USA
| | - Amir Imanzadeh
- Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women’s Hospital, Boston, MA, USA
| | | | - Jeffrey M Karp
- Harvard Stem Cell Institute, Harvard University, Boston, MA, USA
- Harvard-MIT Division of Health Science and Technology, Department of Medicine, Brigham and Women’s Hospital, Boston, MA, USA
| | - C Keith Ozaki
- Department of Surgery, Brigham and Women’s Hospital, Boston, MA, USA
| | - Frank J Rybicki
- Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women’s Hospital, Boston, MA, USA
- Ottawa Hospital Research Institute and Division of Medical Imaging, The Ottawa Hospital Department of Radiology, University of Ottawa, Ottawa, ON, Canada
| |
Collapse
|
4
|
Malik SJ, Hajnal JV. Phase relaxed localized excitation pulses for inner volume fast spin echo imaging. Magn Reson Med 2016; 76:848-61. [PMID: 26451691 PMCID: PMC4988531 DOI: 10.1002/mrm.25996] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 08/20/2015] [Accepted: 08/30/2015] [Indexed: 11/25/2022]
Abstract
PURPOSE To design multidimensional spatially selective radiofrequency (RF) pulses for inner volume imaging (IVI) with three-dimensional (3D) fast spin echo (FSE) sequences. Enhanced background suppression is achieved by exploiting particular signal properties of FSE sequences. THEORY AND METHODS The CPMG condition dictates that echo amplitudes will rapidly decrease if a 90° phase difference between excitation and refocusing pulses is not present, and refocusing flip angles are not precisely 180°. This mechanism is proposed as a means for generating additional background suppression for spatially selective excitation, by biasing residual excitation errors toward violating the CPMG condition. 3D RF pulses were designed using this method with a 3D spherical spiral trajectory, under-sampled by factor 5.6 for an eight-channel PTx system, at 3 Tesla. RESULTS 3D-FSE IVI with pulse durations of approximately 12 ms was demonstrated in phantoms and for T2 -weighted brain imaging in vivo. Good image quality was obtained, with mean background suppression factors of 103 and 82 ± 6 in phantoms and in vivo, respectively. CONCLUSION Inner Volume Imaging with 3D-FSE has been demonstrated in vivo with tailored 3D-RF pulses. The proposed design methods are also applicable to 2D pulses. Magn Reson Med 76:848-861, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Shaihan J. Malik
- Biomedical Engineering Department, Division of Imaging Sciences, King's College LondonSt. Thomas' HospitalLondonUnited Kingdom
| | - Joseph V. Hajnal
- Biomedical Engineering Department, Division of Imaging Sciences, King's College LondonSt. Thomas' HospitalLondonUnited Kingdom
| |
Collapse
|
5
|
Abstract
BACKGROUND Chronic rejection leading to allograft loss remains a significant concern after facial allotransplantation. Chronic rejection may occur without clinical signs or symptoms. The current means of monitoring is histologic analyses of allograft biopsy specimens, which is both invasive and impractical. Prior data suggest that chronic rejection is associated with changes in intima and media thickness of vessels in arms and solid organ allografts; such data have not been published for face transplant recipients. METHODS The authors used a 48-MHz transducer to acquire images of the bilateral facial, radial, dorsalis pedis and, if applicable, sentinel flap arteries in five face transplant recipients (8 months to 4.5 years after transplantation) and five control subjects. The authors assessed the intima, media, and adventitia thickness plus lumen and the total vessel diameter and area. RESULTS Face transplant recipients had thicker intima in all sites compared with controls, but the ratio of the intimal thickness of facial and radial arteries was similar in face transplant recipients compared with controls (1.00 versus 0.95; p = 0.742). Intraobserver correlation showed reliable reproducibility of the measurements (r = 0.935, p ≤ 0.001). Interobserver correlation demonstrated reproducibility of intima measurements (r = 0.422, p ≤ 0.001). CONCLUSION The authors demonstrate that ultrasound biomicroscopy is feasible for postsurgical monitoring, and have developed a new benchmark parameter, the facial artery-to-radial artery intimal thickness ratio, to be used in future testing in the setting of chronic rejection. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, IV.
Collapse
|
6
|
Nguyen BT, Vemula PK, Mitsouras D, Yu P, Tao M, Campagna C, Mulkern RV, Rybicki FJ, Karp JM, Ozaki CK. Immobilization of iron oxide magnetic nanoparticles for enhancement of vessel wall magnetic resonance imaging--an ex vivo feasibility study. Bioconjug Chem 2011; 21:1408-12. [PMID: 20608720 PMCID: PMC2923466 DOI: 10.1021/bc100138c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
![]()
Emerging data supports a role for negative wall remodeling in the failure of vascular interventions such as vein grafts, yet clinicians/researchers currently lack the ability to temporally/efficiently investigate adventitial surface topography/total vascular wall anatomy in vivo. We established a strategy of immobilizing commercially available iron oxide magnetic nanoparticles (Fe-NPs) onto the surface of human vein conduits to facilitate high-throughput total vascular wall demarcation with magnetic resonance (MR). Binding of activated Fe-NPs to amine groups on the surface of the veins induced a thin layer of negative contrast that differentiated the adventitia from surrounding saline signal in all MR images, enabling delineation of total wall anatomy; this was not possible in simultaneously imaged unlabeled control veins. Under the conditions of this ex vivo experiment, stable covalent binding of Fe-NPs can be achieved (dose-dependent) on human vein surface for MR detection, suggesting a potential strategy for enhancing the ability of MRI to investigate total wall adaptation and remodeling in vein graft failure. Emerging data supports a role for negative wall remodeling in the failure of vascular interventions such as vein grafts, yet clinicians/researchers currently lack the ability to temporally/efficiently investigate adventitial surface topography/total vascular wall anatomy in vivo. We established a strategy of immobilizing commercially available iron oxide magnetic nanoparticles (Fe-NPs) onto the surface of human vein conduits to facilitate high-throughput total vascular wall demarcation with magnetic resonance (MR).
Collapse
Affiliation(s)
- Binh Thai Nguyen
- Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Harvard-MIT Division of Heath Sciences &Technology, 65 Landsdowne Street, Cambridge, MA 02139, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Mitsouras D, Vemula PK, Yu P, Tao M, Nguyen BT, Campagna CM, Karp JM, Mulkern RV, Ozaki CK, Rybicki FJ. Immobilized contrast-enhanced MRI: Gadolinium-based long-term MR contrast enhancement of the vein graft vessel wall. Magn Reson Med 2010; 65:176-83. [PMID: 20859994 DOI: 10.1002/mrm.22606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
An implantable MR contrast agent that can be covalently immobilized on tissue during surgery has been developed. The rationale is that a durable increase in tissue contrast using an implantable contrast agent can enhance postsurgical tissue differentiation using MRI. For small-vessel (e.g., vein graft) MRI, the direct benefit of such permanent "labeling" of the vessel wall by modification of its relaxation properties is to achieve more efficient imaging. This efficiency can be realized as either increased contrast leading to more accurate delineation of vessel wall and lesion tissue boundaries, or, faster imaging without penalizing contrast-to-noise ratio, or a combination thereof. We demonstrate, for the first time, stable long-term MRI enhancement using such an exogenous contrast mechanism based on immobilizing a modified diethylenetriaminepentaacetic acid gadolinium(3+) dihydrogen complex on a human vein using a covalent amide bond. Signal enhancement due to the covalently immobilized contrast agent is demonstrated for excised human vein specimens imaged at 3 T, and its long-term stability is demonstrated during a 4-month incubation period.
Collapse
Affiliation(s)
- Dimitris Mitsouras
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Rybicki FJ, Mitsouras D, Owens CD, Whitmore A, Gerhard-Herman M, Wake N, Cai T, Zhou Q, Conte MS, Creager MA, Mulkern RV. Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts. Int J Cardiovasc Imaging 2010; 26:683-91. [PMID: 20333469 DOI: 10.1007/s10554-010-9621-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2010] [Accepted: 03/09/2010] [Indexed: 01/20/2023]
Abstract
The purpose of this study is to primarily evaluate the lumen area and secondarily evaluate wall area measurements of in vivo lower extremity peripheral vein bypass grafts patients using high spatial resolution, limited field of view, cardiac gated, black blood inner volume three-dimensional fast spin echo MRI. Fifteen LE-PVBG patients prospectively underwent ultrasound followed by T1-weighted and T2-weighted magnetic resonance (MR) imaging. Lumen and vessel wall areas were measured by direct planimetry. For graft lumen areas, T1- and T2-weighted measurements were compared with ultrasound. For vessel wall areas, differences between T1- and T2-weighted measurements were evaluated. There was no significant difference between ultrasound and MR lumen measurements, reflecting minimal MR blood suppression artifact. Graft wall area measured from T1-weighted images was significantly larger than that measured from T2-weighted images (P < 0.001). The mean of the ratio of T1- versus T2-weighted vessel wall areas was 1.59 (95% CI: 1.48-1.69). The larger wall area measured on T1-weighted images was due to a significantly larger outer vessel wall boundary. Very high spatial resolution LE-PVBG vessel wall MR imaging can be performed in vivo, enabling accurate measurements of lumen and vessel wall areas and discerning differences in those measures between different tissue contrast weightings. Vessel wall area differences suggest that LE-PVBG vessel wall tissues produce distinct signal characteristics under T1 and T2 MR contrast weightings.
Collapse
Affiliation(s)
- Frank J Rybicki
- Applied Imaging Science Laboratory, Department of Radiology, Brigham and Women's Hospital, Boston, MA, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Mitsouras D, Owens CD, Conte MS, Ersoy H, Creager MA, Rybicki FJ, Mulkern RV. In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE. Magn Reson Med 2009; 62:607-15. [PMID: 19449380 DOI: 10.1002/mrm.22037] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Lower extremity peripheral vein bypass grafts (LE-PVBG) imaged with high-resolution black blood three-dimensional (3D) inner-volume (IV) fast spin echo (FSE) MRI at 1.5 Tesla possess a two-layer appearance in T1W images while only the inner layer appears visible in the corresponding T2W images. This study quantifies this difference in six patients imaged 6 months after implantation, and attributes the difference to the T(2) relaxation rates of vessel wall tissues measured ex vivo in two specimens with histologic correlation. The visual observation of two LE-PVBG vessel wall components imaged in vivo is confirmed to be significant (P < 0.0001), with a mean vessel wall area difference of 6.8 +/- 2.7 mm(2) between contrasts, and a ratio of T1W to T2W vessel wall area of 1.67 +/- 0.28. The difference is attributed to a significantly (P < 0.0001) shorter T(2) relaxation in the adventitia (T(2) = 52.6 +/- 3.5 ms) compared with the neointima/media (T(2) = 174.7 +/- 12.1 ms). Notably, adventitial tissue exhibits biexponential T(2) signal decay (P < 0.0001 vs monoexponential). Our results suggest that high-resolution black blood 3D IV-FSE can be useful for studying the biology of bypass graft wall maturation and pathophysiology in vivo, by enabling independent visualization of the relative remodeling of the neointima/media and adventitia.
Collapse
Affiliation(s)
- Dimitris Mitsouras
- Department of Radiology, Applied Imaging Science Laboratory, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | |
Collapse
|
10
|
Owens CD. Adaptive changes in autogenous vein grafts for arterial reconstruction: clinical implications. J Vasc Surg 2009; 51:736-46. [PMID: 19837532 DOI: 10.1016/j.jvs.2009.07.102] [Citation(s) in RCA: 111] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2009] [Revised: 07/20/2009] [Accepted: 07/24/2009] [Indexed: 01/22/2023]
Abstract
For patients with the most severe manifestations of lower extremity arterial occlusive disease, bypass surgery using autogenous vein has been the most durable reconstruction. However, the incidence of bypass graft stenosis and graft failure remains substantial and wholesale improvements in patency are lacking. One potential explanation is that stenosis arises not only from over exuberant intimal hyperplasia, but also due to insufficient adaptation or remodeling of the vein to the arterial environment. Although in vivo human studies are difficult to conduct, recent advances in imaging technology have made possible a more comprehensive structural examination of vein bypass maturation. This review summarizes recent translational efforts to understand the structural and functional properties of human vein grafts and places it within the context of the rich existing literature of vein graft failure.
Collapse
Affiliation(s)
- Christopher D Owens
- Division of Vascular and Endovascular Surgery, University of California San Francisco, San Francisco, CA 94143, USA.
| |
Collapse
|
11
|
Lower extremity peripheral vein bypass graft wall thickness changes demonstrated at 1 and 6 months after surgery with ultra-high spatial resolution black blood inner volume three-dimensional fast spin echo magnetic resonance imaging. Int J Cardiovasc Imaging 2007; 24:529-33. [DOI: 10.1007/s10554-007-9287-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2007] [Accepted: 12/03/2007] [Indexed: 10/22/2022]
|