• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4682538)   Today's Articles (1095)
For: Schneider JT, Kalayciyan R, Haas M, Herrmann SR, Ruhm W, Hennig J, Ullmann P. Inner-volume imaging in vivo using three-dimensional parallel spatially selective excitation. Magn Reson Med 2012;69:1367-78. [PMID: 22730218 DOI: 10.1002/mrm.24381] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2011] [Revised: 05/24/2012] [Accepted: 05/25/2012] [Indexed: 11/09/2022]
Number Cited by Other Article(s)
1
Yang H, Wang G, Li Z, Li H, Zheng J, Hu Y, Cao X, Liao C, Ye H, Tian Q. Artificial intelligence for neuro MRI acquisition: a review. MAGMA (NEW YORK, N.Y.) 2024;37:383-396. [PMID: 38922525 DOI: 10.1007/s10334-024-01182-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 06/11/2024] [Accepted: 06/14/2024] [Indexed: 06/27/2024]
2
Kazemivalipour E, Wald LL, Guerin B. Comparison of tight-fitting 7T parallel-transmit head array designs using excitation uniformity and local specific absorption rate metrics. Magn Reson Med 2024;91:1209-1224. [PMID: 37927216 PMCID: PMC10848211 DOI: 10.1002/mrm.29900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 09/15/2023] [Accepted: 10/06/2023] [Indexed: 11/07/2023]
3
Williams SN, McElhinney P, Gunamony S. Ultra-high field MRI: parallel-transmit arrays and RF pulse design. Phys Med Biol 2023;68. [PMID: 36410046 DOI: 10.1088/1361-6560/aca4b7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 11/21/2022] [Indexed: 11/22/2022]
4
Meloche R, Vučković I, Mishra PK, Macura S. Transverse relaxation in fixed tissue: Influence of temperature and resolution on image contrast in magnetic resonance microscopy. NMR IN BIOMEDICINE 2022;35:e4747. [PMID: 35467776 DOI: 10.1002/nbm.4747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 04/19/2022] [Accepted: 04/20/2022] [Indexed: 06/14/2023]
5
Geldschläger O, Bosch D, Henning A. OTUP workflow: target specific optimization of the transmit k-space trajectory for flexible universal parallel transmit RF pulse design. NMR IN BIOMEDICINE 2022;35:e4728. [PMID: 35297104 DOI: 10.1002/nbm.4728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Revised: 02/09/2022] [Accepted: 03/14/2022] [Indexed: 06/14/2023]
6
Zhang M, Arango N, Stockmann JP, White J, Adalsteinsson E. Selective RF excitation designs enabled by time-varying spatially non-linear ΔB0 fields with applications in fetal MRI. Magn Reson Med 2021;87:2161-2177. [PMID: 34931714 PMCID: PMC8847339 DOI: 10.1002/mrm.29114] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 10/22/2021] [Accepted: 11/17/2021] [Indexed: 11/08/2022]
7
He X, Auerbach EJ, Garwood M, Kobayashi N, Wu X, Metzger GJ. Parallel transmit optimized 3D composite adiabatic spectral-spatial pulse for spectroscopy. Magn Reson Med 2021;86:17-32. [PMID: 33497006 PMCID: PMC8545499 DOI: 10.1002/mrm.28682] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 12/22/2020] [Accepted: 12/23/2020] [Indexed: 01/05/2023]
8
Geldschläger O, Bosch D, Glaser S, Henning A. Local excitation universal parallel transmit pulses at 9.4T. Magn Reson Med 2021;86:2589-2603. [PMID: 34180089 DOI: 10.1002/mrm.28905] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 06/07/2021] [Accepted: 06/07/2021] [Indexed: 12/30/2022]
9
Vinding MS, Aigner CS, Schmitter S, Lund TE. DeepControl: 2DRF pulses facilitating B 1 + inhomogeneity and B0 off-resonance compensation in vivo at 7 T. Magn Reson Med 2021;85:3308-3317. [PMID: 33480029 DOI: 10.1002/mrm.28667] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Revised: 12/09/2020] [Accepted: 12/09/2020] [Indexed: 01/26/2023]
10
Mullen M, Gutierrez A, Kobayashi N, Haupt J, Garwood M. Accelerated imaging with segmented 2D pulses using parallel imaging and virtual coils. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2019;305:185-194. [PMID: 31302513 PMCID: PMC6711164 DOI: 10.1016/j.jmr.2019.07.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 06/10/2023]
11
Deniz CM. Parallel Transmission for Ultrahigh Field MRI. Top Magn Reson Imaging 2019;28:159-171. [PMID: 31188274 PMCID: PMC7039313 DOI: 10.1097/rmr.0000000000000204] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
12
Luo T, Noll DC, Fessler JA, Nielsen JF. A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration. Magn Reson Med 2019;82:1101-1112. [PMID: 31050011 DOI: 10.1002/mrm.27801] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 04/03/2019] [Accepted: 04/16/2019] [Indexed: 12/11/2022]
13
Phase matched RF pulse design for imaging a reduced field of excitation with a fast TSE acquisition. Magn Reson Imaging 2018;51:128-136. [PMID: 29747015 DOI: 10.1016/j.mri.2018.05.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 05/05/2018] [Accepted: 05/05/2018] [Indexed: 11/24/2022]
14
Wu W, Miller KL. Image formation in diffusion MRI: A review of recent technical developments. J Magn Reson Imaging 2017;46:646-662. [PMID: 28194821 PMCID: PMC5574024 DOI: 10.1002/jmri.25664] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Accepted: 01/25/2017] [Indexed: 12/13/2022]  Open
15
Vinding MS, Guérin B, Vosegaard T, Nielsen NC. Local SAR, global SAR, and power-constrained large-flip-angle pulses with optimal control and virtual observation points. Magn Reson Med 2017;77:374-384. [PMID: 26715084 PMCID: PMC4929033 DOI: 10.1002/mrm.26086] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 11/03/2015] [Accepted: 11/23/2015] [Indexed: 11/11/2022]
16
Schulze M, Reimann K, Seeger A, Klose U, Ernemann U, Hauser TK. Improvement in imaging common temporal bone pathologies at 3 T MRI: small structures benefit from a small field of view. Clin Radiol 2016;72:267.e1-267.e12. [PMID: 28034444 DOI: 10.1016/j.crad.2016.11.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2016] [Revised: 11/04/2016] [Accepted: 11/25/2016] [Indexed: 11/17/2022]
17
Farkash G, Dumez JN, Frydman L. Sculpting 3D spatial selectivity with pairs of 2D pulses: A comparison of methods. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016;273:9-18. [PMID: 27718460 DOI: 10.1016/j.jmr.2016.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Revised: 09/02/2016] [Accepted: 09/03/2016] [Indexed: 06/06/2023]
18
Davids M, Schad LR, Wald LL, Guérin B. Fast three-dimensional inner volume excitations using parallel transmission and optimized k-space trajectories. Magn Reson Med 2016;76:1170-82. [PMID: 26527590 PMCID: PMC4854802 DOI: 10.1002/mrm.26021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2015] [Revised: 09/28/2015] [Accepted: 09/29/2015] [Indexed: 11/05/2022]
19
Padormo F, Beqiri A, Hajnal JV, Malik SJ. Parallel transmission for ultrahigh-field imaging. NMR IN BIOMEDICINE 2016;29:1145-61. [PMID: 25989904 PMCID: PMC4995736 DOI: 10.1002/nbm.3313] [Citation(s) in RCA: 136] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2014] [Revised: 03/27/2015] [Accepted: 03/29/2015] [Indexed: 05/24/2023]
20
Malik SJ, Hajnal JV. Phase relaxed localized excitation pulses for inner volume fast spin echo imaging. Magn Reson Med 2016;76:848-61. [PMID: 26451691 PMCID: PMC4988531 DOI: 10.1002/mrm.25996] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 08/20/2015] [Accepted: 08/30/2015] [Indexed: 11/25/2022]
21
Wu D, Zhang J. Recent Progress in Magnetic Resonance Imaging of the Embryonic and Neonatal Mouse Brain. Front Neuroanat 2016;10:18. [PMID: 26973471 PMCID: PMC4776397 DOI: 10.3389/fnana.2016.00018] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 02/15/2016] [Indexed: 01/21/2023]  Open
22
Sun H, Fessler JA, Noll DC, Nielsen JF. Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016;35:468-79. [PMID: 26390450 PMCID: PMC4792784 DOI: 10.1109/tmi.2015.2478880] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
23
Islam H, Glover GH. Reduced field of view imaging using a static second-order gradient for functional MRI applications. Magn Reson Med 2016;75:817-22. [PMID: 25809723 PMCID: PMC4583326 DOI: 10.1002/mrm.25650] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 12/15/2014] [Accepted: 01/15/2015] [Indexed: 11/07/2022]
24
Sun H, Fessler JA, Noll DC, Nielsen JF. Rapid inner-volume imaging in the steady-state with 3D selective excitation and small-tip fast recovery imaging. Magn Reson Med 2015;76:1217-23. [PMID: 26507586 DOI: 10.1002/mrm.26026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2015] [Revised: 09/30/2015] [Accepted: 10/03/2015] [Indexed: 12/23/2022]
25
Feasibility and evaluation of dual-source transmit 3D imaging of the orbits: Comparison to high-resolution conventional MRI at 3T. Eur J Radiol 2015;84:1150-8. [DOI: 10.1016/j.ejrad.2015.03.008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Revised: 03/01/2015] [Accepted: 03/09/2015] [Indexed: 12/23/2022]
26
Naganawa S. The Technical and Clinical Features of 3D-FLAIR in Neuroimaging. Magn Reson Med Sci 2015;14:93-106. [PMID: 25833275 DOI: 10.2463/mrms.2014-0132] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]  Open
27
Davids M, Ruttorf M, Zollner FG, Schad LR. Fast and robust design of time-optimal k-space trajectories in MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015;34:564-577. [PMID: 25314699 DOI: 10.1109/tmi.2014.2362681] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
28
Wu D, Lei J, Rosenzweig JM, Burd I, Zhang J. In utero localized diffusion MRI of the embryonic mouse brain microstructure and injury. J Magn Reson Imaging 2014;42:717-28. [PMID: 25537944 DOI: 10.1002/jmri.24828] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2014] [Accepted: 12/04/2014] [Indexed: 12/30/2022]  Open
29
Schmitter S, Wu X, Uğurbil K, Van de Moortele PF. Design of parallel transmission radiofrequency pulses robust against respiration in cardiac MRI at 7 Tesla. Magn Reson Med 2014;74:1291-305. [PMID: 25411131 DOI: 10.1002/mrm.25512] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 09/15/2014] [Accepted: 10/13/2014] [Indexed: 12/18/2022]
30
Padormo F, Beqiri A, Malik SJ, Hajnal JV. PRIMO: Precise radiofrequency inference from multiple observations. Magn Reson Med 2014;74:372-83. [DOI: 10.1002/mrm.25404] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Revised: 07/21/2014] [Accepted: 07/21/2014] [Indexed: 11/11/2022]
31
High spatial resolution in vivo magnetic resonance imaging of the human eye, orbit, nervus opticus and optic nerve sheath at 7.0 Tesla. Exp Eye Res 2014;125:89-94. [DOI: 10.1016/j.exer.2014.05.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2014] [Revised: 05/26/2014] [Accepted: 05/31/2014] [Indexed: 11/17/2022]
32
Ophthalmic Magnetic Resonance Imaging at 7 T Using a 6-Channel Transceiver Radiofrequency Coil Array in Healthy Subjects and Patients With Intraocular Masses. Invest Radiol 2014;49:260-70. [DOI: 10.1097/rli.0000000000000049] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
33
Finsterbusch J. Simultaneous functional MRI acquisition of distributed brain regions with high temporal resolution using a 2D-selective radiofrequency excitation. Magn Reson Med 2014;73:683-91. [PMID: 24574142 DOI: 10.1002/mrm.25143] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2013] [Revised: 12/02/2013] [Accepted: 01/03/2014] [Indexed: 12/24/2022]
34
Kraff O, Fischer A, Nagel AM, Mönninghoff C, Ladd ME. MRI at 7 Tesla and above: demonstrated and potential capabilities. J Magn Reson Imaging 2014;41:13-33. [PMID: 24478137 DOI: 10.1002/jmri.24573] [Citation(s) in RCA: 129] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Accepted: 01/03/2014] [Indexed: 12/29/2022]  Open
35
Wu D, Reisinger D, Xu J, Fatemi SA, van Zijl PCM, Mori S, Zhang J. Localized diffusion magnetic resonance micro-imaging of the live mouse brain. Neuroimage 2014;91:12-20. [PMID: 24440780 DOI: 10.1016/j.neuroimage.2014.01.014] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2013] [Revised: 01/06/2014] [Accepted: 01/10/2014] [Indexed: 11/19/2022]  Open
36
Darji N, Patel G, Speck O. Gain of Imaging Fidelity by Employing a Higher Number of Independent Transmit Channels Together with Slice-Selective Radio-Frequency (RF) Shimming at 7T. MATERIALS (BASEL, SWITZERLAND) 2013;7:30-43. [PMID: 28788438 PMCID: PMC5453143 DOI: 10.3390/ma7010030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/24/2013] [Revised: 11/29/2013] [Accepted: 12/16/2013] [Indexed: 11/30/2022]
37
Schneider R, Ritter D, Haueisen J, Pfeuffer J. B0-informed variable density trajectory design for enhanced correction of off-resonance effects in parallel transmission. Magn Reson Med 2013;71:1381-93. [PMID: 23716347 DOI: 10.1002/mrm.24780] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Revised: 02/18/2013] [Accepted: 03/30/2013] [Indexed: 11/06/2022]
38
Haas M, Ullmann P, Schneider JT, Post H, Ruhm W, Hennig J, Zaitsev M. PexLoc-Parallel excitation using local encoding magnetic fields with nonlinear and nonbijective spatial profiles. Magn Reson Med 2012. [PMID: 23203228 DOI: 10.1002/mrm.24559] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA