Cheung CL, Wu M, Fang G, Ho JDL, Liang L, Tan KV, Lin FH, Chang HC, Kwok KW. Omnidirectional Monolithic Marker for Intra-Operative MR-Based Positional Sensing in Closed MRI. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:439-448. [PMID: 37647176 DOI: 10.1109/tmi.2023.3309967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
We present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z).
Collapse
|
2
|
Wang K, Wang J, Jiang P. High-Dose-Rate Three-Dimensional Image-Guided Adaptive Brachytherapy (3D IGABT) for Locally Advanced Cervical Cancer (LACC): A Narrative Review on Imaging Modality and Clinical Evidence. Curr Oncol 2023; 31:50-65. [PMID: 38275830 PMCID: PMC10814120 DOI: 10.3390/curroncol31010004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/16/2023] [Accepted: 12/18/2023] [Indexed: 01/27/2024] Open
Abstract
Background: Brachytherapy (BT) is a critical component of radiotherapy for locally advanced cervical cancer (LACC), and it has rapidly developed in recent decades. Since the advent of three-dimensional image-guided adaptive brachytherapy (3D-IGABT), magnetic resonance imaging (MRI) has emerged as the primary modality for image guidance. Meanwhile, other imaging modalities, such as computed tomography, 18F-fluorodeoxyglucose positron emission tomography, ultrasound, and their combinations have also been widely studied. Materials and methods: We reviewed studies on different imaging modalities utilized for target delineation and planning. Emerging techniques in IGABT like real-time image guidance and 3D printing were also included. We summarized research on their feasibility and concentrated on their clinical outcomes. Results: MRI-guided BT was the gold standard, and CT-guided BT was the most widely applied. Other modalities have shown feasibility and promising efficacy in dosimetry studies and preliminary outcomes. The longer-term clinical outcomes associated with these approaches require further elucidation. Conclusions: As 3D-IGABT was validated by promising clinical outcomes, the future of BT for LACC is expected to progress toward the refinement of more effective image-guided procedures. Moreover, achieving operational consensus and driving technological advancements to mitigate the inherent limitations associated with different imaging modes remain essential.
Collapse
Affiliation(s)
| | | | - Ping Jiang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China; (K.W.); (J.W.)
| |
Collapse
|
3
|
Madore B, Hess AT, van Niekerk AMJ, Hoinkiss DC, Hucker P, Zaitsev M, Afacan O, Günther M. External Hardware and Sensors, for Improved MRI. J Magn Reson Imaging 2023; 57:690-705. [PMID: 36326548 PMCID: PMC9957809 DOI: 10.1002/jmri.28472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 09/26/2022] [Accepted: 09/27/2022] [Indexed: 11/06/2022] Open
Abstract
Complex engineered systems are often equipped with suites of sensors and ancillary devices that monitor their performance and maintenance needs. MRI scanners are no different in this regard. Some of the ancillary devices available to support MRI equipment, the ones of particular interest here, have the distinction of actually participating in the image acquisition process itself. Most commonly, such devices are used to monitor physiological motion or variations in the scanner's imaging fields, allowing the imaging and/or reconstruction process to adapt as imaging conditions change. "Classic" examples include electrocardiography (ECG) leads and respiratory bellows to monitor cardiac and respiratory motion, which have been standard equipment in scan rooms since the early days of MRI. Since then, many additional sensors and devices have been proposed to support MRI acquisitions. The main physical properties that they measure may be primarily "mechanical" (eg acceleration, speed, and torque), "acoustic" (sound and ultrasound), "optical" (light and infrared), or "electromagnetic" in nature. A review of these ancillary devices, as currently available in clinical and research settings, is presented here. In our opinion, these devices are not in competition with each other: as long as they provide useful and unique information, do not interfere with each other and are not prohibitively cumbersome to use, they might find their proper place in future suites of sensors. In time, MRI acquisitions will likely include a plurality of complementary signals. A little like the microbiome that provides genetic diversity to organisms, these devices can provide signal diversity to MRI acquisitions and enrich measurements. Machine-learning (ML) algorithms are well suited at combining diverse input signals toward coherent outputs, and they could make use of all such information toward improved MRI capabilities. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Bruno Madore
- Department of Radiology, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
| | - Aaron T Hess
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Adam MJ van Niekerk
- Karolinska Institutet, Solna, Sweden
- Norwegian University of Science and Technology, Trondheim, Norway
| | | | - Patrick Hucker
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Maxim Zaitsev
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Onur Afacan
- Computational Radiology Laboratory, Department of Radiology, Boston Children’s Hospital, Harvard Medical School, Boston, MA, USA
| | - Matthias Günther
- Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
- University Bremen, Bremen, Germany
| |
Collapse
|
4
|
Schmidt EJ, Olson G, Tokuda J, Alipour A, Watkins RD, Meyer EM, Elahi H, Stevenson WG, Schweitzer J, Dumoulin CL, Johnson T, Kolandaivelu A, Loew W, Halperin HR. Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T. Magn Reson Med 2022; 87:2885-2900. [PMID: 35142398 PMCID: PMC8957513 DOI: 10.1002/mrm.29168] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 11/30/2021] [Accepted: 01/05/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE Develop a deflectable intracardiac MR imaging (ICMRI) guiding-sheath to accelerate imaging during MR-guided electrophysiological (EP) interventions for radiofrequency (500 kHz) ablation (RFA) of arrythmia. Requirements include imaging at three to five times surface-coil SNR in cardiac chambers, vascular insertion, steerable-active-navigation into cardiac chambers, operation with ablation catheters, and safe levels of MR-induced heating. METHODS ICMRI's 6 mm outer-diameter (OD) metallic-braided shaft had a 2.6 mm OD internal lumen for ablation-catheter insertion. Miniature-Baluns (MBaluns) on ICMRI's 1 m shaft reduced body-coil-induced heating. Distal section was a folded "star"-shaped imaging-coil mounted on an expandable frame, with an integrated miniature low-noise-amplifier overcoming cable losses. A handle-activated movable-shaft expanded imaging-coil to 35 mm OD for imaging within cardiac-chambers. Four MR-tracking micro-coils enabled navigation and motion-compensation, assuming a tetrahedron-shape when expanded. A second handle-lever enabled distal-tip deflection. ICMRI with a protruding deflectable EP catheter were used for MR-tracked navigation and RFA using a dedicated 3D-slicer user-interface. ICMRI was tested at 3T and 1.5T in swine to evaluate (a) heating, (b) cardiac-chamber access, (c) imaging field-of-view and SNR, and (d) intraprocedural RFA lesion monitoring. RESULTS The 3T and 1.5T imaging SNR demonstrated >400% SNR boost over a 4 × 4 × 4 cm3 FOV in the heart, relative to body and spine arrays. ICMRI with MBaluns met ASTM/IEC heating limits during navigation. Tip-deflection allowed navigating ICMRI and EP catheter into atria and ventricles. Acute-lesion long-inversion-time-T1-weighted 3D-imaging (TWILITE) ablation-monitoring using ICMRI required 5:30 min, half the time needed with surface arrays alone. CONCLUSION ICMRI assisted EP-catheter navigation to difficult targets and accelerated RFA monitoring.
Collapse
Affiliation(s)
- Ehud J. Schmidt
- Medicine (Cardiology)Johns Hopkins UniversityBaltimoreMarylandUSA
| | - Gregory Olson
- Cardiac Arrhythmia and Heart Failure DivisionAbbott LaboratoriesMinnetonkaMinnesotaUSA
| | - Junichi Tokuda
- RadiologyBrigham and Women’s HospitalBostonMassachusettsUSA
| | - Akbar Alipour
- Medicine (Cardiology)Johns Hopkins UniversityBaltimoreMarylandUSA
| | | | - Eric M. Meyer
- Medicine (Cardiology)Johns Hopkins UniversityBaltimoreMarylandUSA
| | - Hassan Elahi
- Medicine (Cardiology)Johns Hopkins UniversityBaltimoreMarylandUSA
| | | | - Jeffrey Schweitzer
- Cardiac Arrhythmia and Heart Failure DivisionAbbott LaboratoriesMinnetonkaMinnesotaUSA
| | | | | | | | - Wolfgang Loew
- RadiologyCincinnati Children’s Hospital Medical CenterCincinnatiOhioUSA
| | | |
Collapse
|
5
|
Gunderman AL, Schmidt EJ, Morcos M, Tokuda J, Seethamraju RT, Halperin HR, Viswanathan AN, Chen Y. MR-Tracked Deflectable Stylet for Gynecologic Brachytherapy. IEEE/ASME TRANSACTIONS ON MECHATRONICS : A JOINT PUBLICATION OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY AND THE ASME DYNAMIC SYSTEMS AND CONTROL DIVISION 2022; 27:407-417. [PMID: 35185321 PMCID: PMC8855967 DOI: 10.1109/tmech.2021.3064954] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Brachytherapy is a radiation based treatment that is implemented by precisely placing focused radiation sources into tumors. In advanced interstitial cervical cancer bracytherapy treatment, this is performed by placing a metallic rod ("stylet") inside a hollow cylindrical tube ("catheter") and advancing the pair to the desired target. The stylet is removed once the target is reached, followed by the insertion of radiation sources into the catheter. However, manually advancing an initially straight stylet into the tumor with millimeter spatial accuracy has been a long-standing challenge, which requires multiple insertions and retractions, due to the unforeseen stylet deflection caused by the stiff muscle tissue that is traversed. In this paper, we develop a novel tendon-actuated deflectable stylet equipped with MR active-tracking coils that may enhance brachytherapy treatment outcomes by allowing accurate stylet trajectory control. Herein we present the design concept and fabrication method, followed by the kinematic and mechanics models of the deflectable stylet. The hardware and theoretical models are extensively validated via benchtop and MRI-guided characterization. At insertion depths of 60 mm, benchtop phantom targeting tests provided a targeting error of 1. 23 ± 0. 47 mm, and porcine tissue targeting tests provided a targeting error of 1. 65 ± 0. 64 mm, after only a single insertion. MR-guided experiments indicate that the stylet can be safely and accurately located within the MRI environment.
Collapse
Affiliation(s)
- Anthony L Gunderman
- Mechanical Engineering Department, University of Arkansas, Fayetteville, AR 72701 USA
| | - Ehud J Schmidt
- Department of Medicine, Johns Hopkins University, Baltimore, MD., 21205
| | - Marc Morcos
- Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD., 21205
| | - Junichi Tokuda
- Department of Radiology, Harvard Medical School, Boston, MA., 02115
| | | | - Henry R Halperin
- Department of Medicine, Johns Hopkins University, Baltimore, MD., 21205
| | - Akila N Viswanathan
- Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD., 21205
| | - Yue Chen
- Mechanical Engineering Department, University of Arkansas, Fayetteville, AR 72701 USA
| |
Collapse
|
6
|
Elledge CR, LaVigne AW, Bhatia RK, Viswanathan AN. Aiming for 100% Local Control in Locally Advanced Cervical Cancer: The Role of Complex Brachytherapy Applicators and Intraprocedural Imaging. Semin Radiat Oncol 2020; 30:300-310. [PMID: 32828386 PMCID: PMC7875154 DOI: 10.1016/j.semradonc.2020.05.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
The use of brachytherapy for the treatment of gynecologic malignancies, particularly cervical cancer, has a long and rich history that is nearly as long as the history of radiation oncology itself. From the first gynecologic brachytherapy treatments in the early 20th century to the modern era, significant transformation has occurred driven largely by advancements in technology. The development of high-dose rate sources, remote afterloaders, novel applicators, and 3-dimensional image guidance has led to improved local control, and thus improved survival, solidifying the role of brachytherapy as an integral component in the treatment of locally advanced cervical cancer. Current research efforts examining novel magnetic resonance imaging sequences, active magnetic resonance tracking, and the application of hydrogel aim to further improve local control and reduce treatment toxicity.
Collapse
Affiliation(s)
- Christen R Elledge
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Anna W LaVigne
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Rohini K Bhatia
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD
| | - Akila N Viswanathan
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD.
| |
Collapse
|
7
|
Ning MS, Venkatesan AM, Stafford RJ, Bui TP, Carlson R, Bailard NS, Vedam S, Davis R, Olivieri ND, Guzman AB, Incalcaterra JR, McKelvey FA, Thaker NG, Rauch GM, Tang C, Frank SJ, Joyner MM, Lin LL, Jhingran A, Eifel PJ, Klopp AH. Developing an intraoperative 3T MRI-guided brachytherapy program within a diagnostic imaging suite: Methods, process workflow, and value-based analysis. Brachytherapy 2020; 19:427-437. [DOI: 10.1016/j.brachy.2019.09.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 09/11/2019] [Accepted: 09/21/2019] [Indexed: 12/22/2022]
|
8
|
Martell K, Law C, Hasan Y, Taggar A, Barnes E, Ravi A, Leung E. Using infrared depth-sensing technology to improve the brachytherapy operating room experience. Brachytherapy 2020; 19:323-327. [PMID: 32220519 DOI: 10.1016/j.brachy.2020.02.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Revised: 01/31/2020] [Accepted: 02/06/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE The purpose of this study was to discuss the merits of using depth-sensing infrared camera technology in the brachytherapy operating room during interstitial brachytherapy for gynecologic malignancies. MATERIALS AND METHODS The infrared depth-sensing camera from a Microsoft Kinect that had been adapted for surgical use was introduced into a high-volume interstitial brachytherapy operating room. Brachytherapists then used the touchless, gestural interface to review preoperative MRI in real time to guide needle insertion. RESULTS The interface was used for 10 consecutive procedures by 4 separate brachytherapists. The initial training and adjustment to the technology was variable among brachytherapists. All brachytherapists found the controls intuitive and were able to successfully navigate MRI on the system after 1, 30, 30, and 45 min. Qualitatively, brachytherapists found the system helpful for interpretation of intraoperative ultrasound imaging. Furthermore, it ensured adequate needle positioning and deposition was maintained for large tumors. Surgeons involved in its use agreed on potential for considerable benefit when performing interstitial brachytherapy. CONCLUSIONS Adapting this technology for use in the brachytherapy suite provided a higher level of comfort with interstitial catheter placement. This novel tool or similar technology might be considered within other brachytherapy suites.
Collapse
Affiliation(s)
- Kevin Martell
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario; Department of Oncology, University of Calgary, Calgary, Alberta; Tom Baker Cancer Centre, Calgary, Alberta
| | - Calvin Law
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario
| | - Yaser Hasan
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario
| | - Amandeep Taggar
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario
| | - Elizabeth Barnes
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario
| | - Ananth Ravi
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario
| | - Eric Leung
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario; Sunnybrook Health Sciences Centre, Toronto, Ontario.
| |
Collapse
|
9
|
Cunha JAM, Flynn R, Bélanger C, Callaghan C, Kim Y, Jia X, Chen Z, Beaulieu L. Brachytherapy Future Directions. Semin Radiat Oncol 2020; 30:94-106. [DOI: 10.1016/j.semradonc.2019.09.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
10
|
Alipour A, Meyer ES, Dumoulin CL, Watkins RD, Elahi H, Loew W, Schweitzer J, Olson G, Chen Y, Tao S, Guttman M, Kolandaivelu A, Halperin HR, Schmidt EJ. MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation. IEEE Trans Biomed Eng 2019; 67:1616-1627. [PMID: 31535979 DOI: 10.1109/tbme.2019.2941460] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVE Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.
Collapse
|
11
|
Zijlstra F, Viergever MA, Seevinck PR. SMART tracking: Simultaneous anatomical imaging and real-time passive device tracking for MR-guided interventions. Phys Med 2019; 64:252-260. [DOI: 10.1016/j.ejmp.2019.07.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 07/18/2019] [Accepted: 07/24/2019] [Indexed: 11/27/2022] Open
|
12
|
Beld E, Moerland MA, van der Voort van Zyp JRN, Viergever MA, Lagendijk JJW, Seevinck PR. MRI artifact simulation for clinically relevant MRI sequences for guidance of prostate HDR brachytherapy. Phys Med Biol 2019; 64:095006. [PMID: 30947159 DOI: 10.1088/1361-6560/ab15ed] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
For the purpose of magnetic resonance imaging (MRI) guidance of prostate high-dose-rate (HDR) brachytherapy, this paper presents a study on the potential of clinically relevant MRI sequences to facilitate tracking or localization of brachytherapy devices (HDR source/titanium needle), and which could simultaneously be used to visualize the anatomy. The tracking or localization involves simulation of the MRI artifact in combination with a template matching algorithm. Simulations of the MRI artifacts induced by an HDR brachytherapy source and a titanium needle were implemented for four types of sequences: spoiled gradient echo, spin echo, balanced steady-state free precession (bSSFP) and bSSFP with spectral attenuated inversion recovery (SPAIR) fat suppression. A phantom study was conducted in which mentioned sequences (in 2D) as well as the volumetric MRI sequences of the current clinical scan protocol were applied to obtain the induced MRI artifacts for an HDR source and a titanium needle. Localization of the objects was performed by a phase correlation based template matching algorithm. The simulated images demonstrated high correspondences with the acquired MR images, and allowed localization of the objects. A comparison between the object positions obtained for all applied MRI sequences showed deviations (from the average position) of 0.2-0.3 mm, proving that all MRI sequences were suitable for localization of the objects, irrespective of their 2D or volumetric nature. This study demonstrated that the MRI artifact induced by an HDR source or a titanium needle could be simulated for the four investigated types of MRI sequences (spoiled gradient echo, spin echo, bSSFP and bSSFP-SPAIR), valuable for real-time object localization in clinical practice. This leads to more flexibility in the choice of MRI sequences for guidance of HDR brachytherapy, as they are suitable for both object localization and anatomy visualization.
Collapse
Affiliation(s)
- Ellis Beld
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands. Author to whom correspondence may be addressed
| | | | | | | | | | | |
Collapse
|
13
|
Guo Z, Leong MCW, Su H, Kwok KW, Chan DTM, Poon WS. Techniques for Stereotactic Neurosurgery: Beyond the Frame, Toward the Intraoperative Magnetic Resonance Imaging–Guided and Robot-Assisted Approaches. World Neurosurg 2018; 116:77-87. [DOI: 10.1016/j.wneu.2018.04.155] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 04/20/2018] [Accepted: 04/21/2018] [Indexed: 11/16/2022]
|
14
|
Guo Z, Dong Z, Lee KH, Cheung CL, Fu HC, Ho JD, He H, Poon WS, Chan DTM, Kwok KW. Compact Design of a Hydraulic Driving Robot for Intraoperative MRI-Guided Bilateral Stereotactic Neurosurgery. IEEE Robot Autom Lett 2018. [DOI: 10.1109/lra.2018.2814637] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
15
|
Beld E, Moerland MA, Zijlstra F, Viergever MA, Lagendijk JJW, Seevinck PR. MR-based source localization for MR-guided HDR brachytherapy. Phys Med Biol 2018. [PMID: 29516866 DOI: 10.1088/1361-6560/aab50b] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4-0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15-1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.
Collapse
Affiliation(s)
- E Beld
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX, Utrecht, Netherlands
| | | | | | | | | | | |
Collapse
|
16
|
Experimental validation of robot-assisted cardiovascular catheterization: model-based versus model-free control. Int J Comput Assist Radiol Surg 2018; 13:797-804. [PMID: 29611096 DOI: 10.1007/s11548-018-1757-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 03/26/2018] [Indexed: 10/17/2022]
Abstract
PURPOSE In cardiac electrophysiology, a long and flexible catheter is delivered to a cardiac chamber for the treatment of arrhythmias. Although several robot-assisted platforms have been commercialized, the disorientation in tele-operation is still not well solved. We propose a validation platform for robot-assisted cardiac EP catheterization, integrating a customized MR Safe robot, a standard clinically used EP catheter, and a human-robot interface. Both model-based and model-free control methods are implemented in the platform for quantitative evaluation and comparison. METHODS The model-based and model-free control methods were validated by subject test (ten participants), in which the subjects have to perform a simulated radiofrequency ablation task using both methods. A virtual endoscopic view of the catheter is also provided to enhance hand-to-eye coordination. Assessment indices for targeting accuracy and efficiency were acquired for the evaluation. RESULTS (1) Accuracy: The average distance measured from catheter tip to the closest lesion target during ablation of model-free method was 19.1% shorter than that of model-based control. (2) Efficiency: The model-free control reduced the total missed targets by 35.8% and the maximum continuously missed targets by 46.2%, both indices corresponded to a low p value ([Formula: see text]). CONCLUSION The model-free method performed better in terms of both accuracy and efficiency, indicating the model-free control could adapt to soft interaction with environment, as compared with the model-based control that does not consider contacts.
Collapse
|
17
|
Mastmeyer A, Pernelle G, Ma R, Barber L, Kapur T. Accurate model-based segmentation of gynecologic brachytherapy catheter collections in MRI-images. Med Image Anal 2017; 42:173-188. [PMID: 28803217 PMCID: PMC5654713 DOI: 10.1016/j.media.2017.06.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2017] [Revised: 05/17/2017] [Accepted: 06/26/2017] [Indexed: 12/31/2022]
Abstract
The gynecological cancer mortality rate, including cervical, ovarian, vaginal and vulvar cancers, is more than 20,000 annually in the US alone. In many countries, including the US, external-beam radiotherapy followed by high dose rate brachytherapy is the standard-of-care. The superior ability of MR to visualize soft tissue has led to an increase in its usage in planning and delivering brachytherapy treatment. A technical challenge associated with the use of MRI imaging for brachytherapy, in contrast to that of CT imaging, is the visualization of catheters that are used to place radiation sources into cancerous tissue. We describe here a precise, accurate method for achieving catheter segmentation and visualization. The algorithm, with the assistance of manually provided tip locations, performs segmentation using image-features, and is guided by a catheter-specific, estimated mechanical model. A final quality control step removes outliers or conflicting catheter trajectories. The mean Hausdorff error on a 54 patient, 760 catheter reference database was 1.49 mm; 51 of the outliers deviated more than two catheter widths (3.4 mm) from the gold standard, corresponding to catheter identification accuracy of 93% in a Syed-Neblett template. In a multi-user simulation experiment for evaluating RMS precision by simulating varying manually-provided superior tip positions, 3σ maximum errors were 2.44 mm. The average segmentation time for a single catheter was 3 s on a standard PC. The segmentation time, accuracy and precision, are promising indicators of the value of this method for clinical translation of MR-guidance in gynecologic brachytherapy and other catheter-based interventional procedures.
Collapse
Affiliation(s)
- Andre Mastmeyer
- Institute of Medical Informatics, University of Luebeck, Germany.
| | | | - Ruibin Ma
- Department of Radiology, Brigham and Women's Hospital, Boston, MA, United States
| | | | - Tina Kapur
- Department of Radiology, Brigham and Women's Hospital, Boston, MA, United States; Harvard Medical School, Boston, MA, United States.
| |
Collapse
|
18
|
Alipour A, Gokyar S, Algin O, Atalar E, Demir HV. An inductively coupled ultra-thin, flexible, and passive RF resonator for MRI marking and guiding purposes: Clinical feasibility. Magn Reson Med 2017; 80:361-370. [PMID: 29148092 DOI: 10.1002/mrm.26996] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 09/17/2017] [Accepted: 10/15/2017] [Indexed: 12/20/2022]
Abstract
PURPOSE The purpose of this study is to develop a wireless, flexible, ultra-thin, and passive radiofrequency-based MRI resonant fiducial marker, and to validate its feasibility in a phantom model and several body regions. METHODS Standard microfabrication processing was used to fabricate the resonant marker. The proposed marker consists of two metal traces in the shape of a square with an edge length of 8 mm, with upper and lower traces connected to each other by a metalized via. A 3T MRI fiducial marking procedure was tested in phantom and ex vivo, and then the marker's performance was evaluated in an MRI experiment using humans. The radiofrequency safety was also tested using temperature sensors in the proximity of the resonator. RESULTS A flexible resonator with a thickness of 115 μm and a dimension of 8 × 8 mm was obtained. The experimental results in the phantom show that at low background flip angles (6-18°), the resonant marker enables precise and rapid visibility, with high marker-to-background contrast and signal-to-noise ratio improvement of greater than 10 in the vicinity of the marker. Temperature analysis showed a specific absorption ratio gain of 1.3. Clinical studies further showed a successful biopsy procedure using the fiducial marking functionality of our device. CONCLUSIONS The ultra-thin and flexible structure of this wireless flexible radiofrequency resonant marker offers effective and safe MR visualization with high feasibility for anatomic marking and guiding at various regions of the body. Magn Reson Med 80:361-370, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Akbar Alipour
- Department of Electrical and Electronics Engineering, National Magnetic Resonance Research Center (UMRAM) National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM) Department of Physics, Bilkent University, Bilkent, Ankara, Turkey
| | - Sayim Gokyar
- Department of Electrical and Electronics Engineering, National Magnetic Resonance Research Center (UMRAM) National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM) Department of Physics, Bilkent University, Bilkent, Ankara, Turkey
| | - Oktay Algin
- Department of Electrical and Electronics Engineering, National Magnetic Resonance Research Center (UMRAM) National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM) Department of Physics, Bilkent University, Bilkent, Ankara, Turkey.,Department of Radiology, Ankara Ataturk Training and Research Hospital, Ankara, Turkey
| | - Ergin Atalar
- Department of Electrical and Electronics Engineering, National Magnetic Resonance Research Center (UMRAM) National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM) Department of Physics, Bilkent University, Bilkent, Ankara, Turkey
| | - Hilmi Volkan Demir
- Department of Electrical and Electronics Engineering, National Magnetic Resonance Research Center (UMRAM) National Nanotechnology Research Center and Institute of Material Science and Nanotechnology (UNAM) Department of Physics, Bilkent University, Bilkent, Ankara, Turkey.,LUMINOUS! Center of Excellence for Semiconductor Lighting and Displays, School of Electrical and Electronic Engineering, School of Mathematical and Physical Sciences, Nanyang Technological University, Singapore
| |
Collapse
|
19
|
de Arcos J, Schmidt EJ, Wang W, Tokuda J, Vij K, Seethamraju RT, Damato AL, Dumoulin CL, Cormack RA, Viswanathan AN. Prospective Clinical Implementation of a Novel Magnetic Resonance Tracking Device for Real-Time Brachytherapy Catheter Positioning. Int J Radiat Oncol Biol Phys 2017; 99:618-626. [PMID: 28843373 DOI: 10.1016/j.ijrobp.2017.05.054] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 05/05/2017] [Accepted: 05/31/2017] [Indexed: 10/19/2022]
Abstract
PURPOSE We designed and built dedicated active magnetic resonance (MR)-tracked (MRTR) stylets. We explored the role of MRTR in a prospective clinical trial. METHODS AND MATERIALS Eleven gynecologic cancer patients underwent MRTR to rapidly optimize interstitial catheter placement. MRTR catheter tip location and orientation were computed and overlaid on images displayed on in-room monitors at rates of 6 to 16 frames per second. Three modes of actively tracked navigation were analyzed: coarse navigation to the approximate region around the tumor; fine-tuning, bringing the stylets to the desired location; and pullback, with MRTR stylets rapidly withdrawn from within the catheters, providing catheter trajectories for radiation treatment planning (RTP). Catheters with conventional stylets were inserted, forming baseline locations. MRTR stylets were substituted, and catheter navigation was performed by a clinician working inside the MRI bore, using monitor feedback. RESULTS Coarse navigation allowed repositioning of the MRTR catheters tips by 16 mm (mean), relative to baseline, in 14 ± 5 s/catheter (mean ± standard deviation [SD]). The fine-tuning mode repositioned the catheter tips by a further 12 mm, in 24 ± 17 s/catheter. Pullback mode provided catheter trajectories with RTP point resolution of ∼1.5 mm, in 1 to 9 s/catheter. CONCLUSIONS MRTR-based navigation resulted in rapid and optimal placement of interstitial brachytherapy catheters. Catheters were repositioned compared with the initial insertion without tracking. In pullback mode, catheter trajectories matched computed tomographic precision, enabling their use for RTP.
Collapse
Affiliation(s)
- Jose de Arcos
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts.
| | - Ehud J Schmidt
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts; Department of Medicine, Johns Hopkins Medicine, Baltimore, Maryland
| | - Wei Wang
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Junichi Tokuda
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts
| | - Kamal Vij
- Department of Radiation Oncology, Brigham and Women's Hospital, Boston, Massachusetts
| | | | - Antonio L Damato
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | | | - Robert A Cormack
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio
| | - Akila N Viswanathan
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio; Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Sidney Kimmel Cancer Center, Baltimore, Maryland.
| |
Collapse
|
20
|
Wang J, Tanderup K, Cunha A, Damato AL, Cohen GN, Kudchadker RJ, Mourtada F. Magnetic resonance imaging basics for the prostate brachytherapist. Brachytherapy 2017; 16:715-727. [PMID: 28396178 DOI: 10.1016/j.brachy.2017.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2016] [Revised: 02/23/2017] [Accepted: 03/04/2017] [Indexed: 11/27/2022]
Abstract
Magnetic resonance imaging (MRI) is increasingly being used in radiation therapy, and integration of MRI into brachytherapy in particular is becoming more common. We present here a systematic review of the basic physics and technical aspects of incorporating MRI into prostate brachytherapy. Terminology and MRI system components are reviewed along with typical work flows in prostate high-dose-rate and low-dose-rate brachytherapy. In general, the brachytherapy workflow consists of five key components: diagnosis, implantation, treatment planning (scan + plan), implant verification, and delivery. MRI integration is discussed for diagnosis; treatment planning; and MRI-guided brachytherapy implants, in which MRI is used to guide the physical insertion of the brachytherapy applicator or needles. Considerations and challenges for establishing an MRI brachytherapy program are also discussed.
Collapse
Affiliation(s)
- Jihong Wang
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX.
| | - Kari Tanderup
- Department of Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - Adam Cunha
- Department of Radiation Oncology, University of California-San Francisco, CA
| | - Antonio L Damato
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Gil'ad N Cohen
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Rajat J Kudchadker
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX
| | - Firas Mourtada
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX; Department of Radiation Oncology, Helen F. Graham Cancer Center, Newark, DE; Department of Radiation Oncology, Bodine Cancer Center, Thomas Jefferson University, Philadelphia, PA.
| |
Collapse
|
21
|
Ménard C, Pambrun JF, Kadoury S. The utilization of magnetic resonance imaging in the operating room. Brachytherapy 2017; 16:754-760. [PMID: 28139421 DOI: 10.1016/j.brachy.2016.12.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 12/12/2016] [Accepted: 12/12/2016] [Indexed: 11/26/2022]
Abstract
Online image guidance in the operating room using ultrasound imaging led to the resurgence of prostate brachytherapy in the 1980s. Here we describe the evolution of integrating MRI technology in the brachytherapy suite or operating room. Given the complexity, cost, and inherent safety issues associated with MRI system integration, first steps focused on the computational integration of images rather than systems. This approach has broad appeal given minimal infrastructure costs and efficiencies comparable with standard care workflows. However, many concerns remain regarding accuracy of registration through the course of a brachytherapy procedure. In selected academic institutions, MRI systems have been integrated in or near the brachytherapy suite in varied configurations to improve the precision and quality of treatments. Navigation toolsets specifically adapted to prostate brachytherapy are in development and are reviewed.
Collapse
Affiliation(s)
- C Ménard
- University of Montréal Hospital Research Centre (CRCHUM), Montréal, QC, Canada; TECHNA Institute, University of Toronto, Toronto, ON, Canada; Princess Margaret Cancer Center, Toronto, ON, Canada.
| | - J-F Pambrun
- University of Montréal Hospital Research Centre (CRCHUM), Montréal, QC, Canada; École polytechnique de Montréal, Montréal, QC, Canada
| | - S Kadoury
- University of Montréal Hospital Research Centre (CRCHUM), Montréal, QC, Canada; École polytechnique de Montréal, Montréal, QC, Canada
| |
Collapse
|
22
|
Wang W, Viswanathan AN, Damato AL, Chen Y, Tse Z, Pan L, Tokuda J, Seethamraju RT, Dumoulin CL, Schmidt EJ, Cormack RA. Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy. Med Phys 2016; 42:7114-21. [PMID: 26632065 DOI: 10.1118/1.4935535] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. METHODS The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter's trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter's imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. RESULTS The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet's orientation deviated from the main magnetic field direction. Fifteen catheters' trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. CONCLUSIONS The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.
Collapse
Affiliation(s)
- Wei Wang
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115 and Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115
| | - Akila N Viswanathan
- Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115
| | - Antonio L Damato
- Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115
| | - Yue Chen
- Department of Engineering, The University of Georgia, Athens, Georgia 30602
| | - Zion Tse
- Department of Engineering, The University of Georgia, Athens, Georgia 30602
| | - Li Pan
- Siemens Healthcare USA, Baltimore, Maryland 21287
| | - Junichi Tokuda
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115
| | | | - Charles L Dumoulin
- Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio 45229
| | - Ehud J Schmidt
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115
| | - Robert A Cormack
- Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women's Hospital, Boston, Massachusetts 02115
| |
Collapse
|
23
|
Chen Y, Wang W, Schmidt EJ, Kwok KW, Viswanathan AN, Cormack R, Tse ZTH. Design and Fabrication of MR-Tracked Metallic Stylet for Gynecologic Brachytherapy. IEEE/ASME TRANSACTIONS ON MECHATRONICS : A JOINT PUBLICATION OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY AND THE ASME DYNAMIC SYSTEMS AND CONTROL DIVISION 2016; 21:956-962. [PMID: 28989272 PMCID: PMC5627614 DOI: 10.1109/tmech.2015.2503427] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Active magnetic resonance (MR) tracking for gynecologic brachytherapy was made possible by attaching the micro radiofrequency coils to the brachytherapy applicator. The rectangular planar micro coil was fabricated using flexible printed circuits with dimensions of 8mm×1.5mm. A 5-Fr (1.6mm) tungsten brachytherapy stylet was custom-machined to incorporate the micro coils. The finite element analysis and the phantom tissue studies show that the proposed device enables in situ, real-time guidance of access routes to the target anatomy safely and accurately. The setup was tested in a Siemens 3T MR scanner. The micro coils can be localized rapidly (up to 40 Hz) and precisely (resolution: 0.6×0.6×0.6mm3) using an MR-tracking sequence.
Collapse
Affiliation(s)
- Yue Chen
- College of Engineering, The University of Georgia, Athens, GA, 30605 USA, and is also with Department of Mechanical Engineering, The University of Hong Kong, HK, China (, )
| | - Wei Wang
- Department of Radiology, Brigham & Women's Hospital, Boston, MA, 02115 USA, and is also with the Department of Radiation Oncology, Brigham & Women's Hospital, Boston, MA, 02115 USA
| | - Ehud J Schmidt
- Department of Radiology, Brigham & Women's Hospital, Boston, MA, 02115 USA
| | - Ka-Wai Kwok
- Department of Mechanical Engineering, The University of Hong Kong, HK, China
| | - Akila N Viswanathan
- Department of Radiation Oncology, Brigham & Women's Hospital, Boston, MA, 02115
| | - Robert Cormack
- Department of Radiation Oncology, Brigham & Women's Hospital, Boston, MA, 02115
| | - Zion Tsz Ho Tse
- College of Engineering, The University of Georgia, Athens, GA, 30605 USA
| |
Collapse
|
24
|
|
25
|
Campbell-Washburn AE, Faranesh AZ, Lederman RJ, Hansen MS. Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions. Magn Reson Imaging Clin N Am 2015; 23:669-79. [PMID: 26499283 DOI: 10.1016/j.mric.2015.05.006] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Interventional MR uses rapid imaging to guide diagnostic and therapeutic procedures. One of the attractions of MR-guidance is the abundance of inherent contrast mechanisms available. Dynamic procedural guidance with real-time imaging has pushed the limits of MR technology, demanding rapid acquisition and reconstruction paired with interactive control and device visualization. This article reviews the technical aspects of real-time MR sequences that enable MR-guided interventions.
Collapse
Affiliation(s)
- Adrienne E Campbell-Washburn
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 9000 Rockville Pike, Building 10, Room B1D416, Bethesda, MD 20892, USA.
| | - Anthony Z Faranesh
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 9000 Rockville Pike, Building 10, Room 2C713, Bethesda, MD 20892, USA
| | - Robert J Lederman
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 9000 Rockville Pike, Building 10, Room 2C713, Bethesda, MD 20892, USA
| | - Michael S Hansen
- Cardiovascular and Pulmonary Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, 9000 Rockville Pike, Building 10, Room B1D416, Bethesda, MD 20892, USA
| |
Collapse
|
26
|
Abstract
Several advantages of MR imaging compared with other imaging modalities have provided the rationale for increased attention to MR-guided interventions, including its excellent soft tissue contrast, its capability to show both anatomic and functional information, and no use of ionizing radiation. An important aspect of MR-guided intervention is to provide visualization and navigation of interventional devices relative to the surrounding tissues. This article focuses on the methods for MR-guided active tracking in catheter-based interventions. Practical issues about implementation of active catheter tracking in a clinical setting are discussed and several current application examples are highlighted.
Collapse
Affiliation(s)
- Wei Wang
- Radiology, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Avenue, Boston, MA 02115, USA.
| |
Collapse
|