1
|
Bruns C, Ringleb R, Prediger I, Euchner F, Bernarding J, Plaumann M. Organic Fluorine Compounds and Their Uses as Molecular MR-Based Temperature Sensors. Chemphyschem 2023; 24:e202300512. [PMID: 37632422 DOI: 10.1002/cphc.202300512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/25/2023] [Accepted: 08/25/2023] [Indexed: 08/28/2023]
Abstract
The interest in fluorinated substances has increased significantly in recent decades due to their diverse properties and possible uses. An important analytical method in this context is NMR spectroscopy, which provides information on the structure as well as on intermolecular interactions or generally on changes in the environment of the nucleus under consideration. A physical quantity that is of great importance in most studies is temperature. However, this is not always easy, e. g. in shielded systems or within an organism. However, the application potential in chemical reactors or in medical diagnosis and therapy is very high and for this reason 13 fluorinated organic compound were chosen for a first 19 F NMR signal temperature sensitivity examination for determination of local temperatures in solution. Polyfluorinated molecules with separate 19 F MR signals are particularly suitable for temperature determination. Those can be serve as internal error-correcting thermometers without the need of a reference substance. Under these conditions, a 19 F MR signal shift of up to 0.03 ppm/K was detectable. Fluorine position and chemical environment were very important for the temperature sensitivity.
Collapse
Affiliation(s)
- Christian Bruns
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Rainer Ringleb
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Isabell Prediger
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Frederike Euchner
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Johannes Bernarding
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| | - Markus Plaumann
- Otto-von-Guericke University Magdeburg, Medical Faculty, Institute of Biometry and Medical Informatics, Leipziger Str. 44, 39120, Magdeburg, Germany
| |
Collapse
|
2
|
De Tommasi F, Massaroni C, Grasso RF, Carassiti M, Schena E. Temperature Monitoring in Hyperthermia Treatments of Bone Tumors: State-of-the-Art and Future Challenges. SENSORS (BASEL, SWITZERLAND) 2021; 21:5470. [PMID: 34450911 PMCID: PMC8400360 DOI: 10.3390/s21165470] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 08/05/2021] [Accepted: 08/10/2021] [Indexed: 12/22/2022]
Abstract
Bone metastases and osteoid osteoma (OO) have a high incidence in patients facing primary lesions in many organs. Radiotherapy has long been the standard choice for these patients, performed as stand-alone or in conjunction with surgery. However, the needs of these patients have never been fully met, especially in the ones with low life expectancy, where treatments devoted to pain reduction are pivotal. New techniques as hyperthermia treatments (HTs) are emerging to reduce the associated pain of bone metastases and OO. Temperature monitoring during HTs may significantly improve the clinical outcomes since the amount of thermal injury depends on the tissue temperature and the exposure time. This is particularly relevant in bone tumors due to the adjacent vulnerable structures (e.g., spinal cord and nerve roots). In this Review, we focus on the potential of temperature monitoring on HT of bone cancer. Preclinical and clinical studies have been proposed and are underway to investigate the use of different thermometric techniques in this scenario. We review these studies, the principle of work of the thermometric techniques used in HTs, their strengths, weaknesses, and pitfalls, as well as the strategies and the potential of improving the HTs outcomes.
Collapse
Affiliation(s)
- Francesca De Tommasi
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| | - Rosario Francesco Grasso
- Unit of Interventional Radiology, School of Medicine, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy;
| | - Massimiliano Carassiti
- Unit of Anesthesia, Intensive Care and Pain Management, School of Medicine, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy;
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentations, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Rome, Italy; (F.D.T.); (C.M.)
| |
Collapse
|
3
|
Bitton RR, Rosenberg J, LeBlang S, Napoli A, Meyer J, Butts Pauly K, Hurwitz M, Ghanouni P. MRI-Guided Focused Ultrasound of Osseous Metastases: Treatment Parameters Associated With Successful Pain Reduction. Invest Radiol 2021; 56:141-146. [PMID: 32858582 DOI: 10.1097/rli.0000000000000721] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND A phase 3 multicenter trial demonstrated that magnetic resonance imaging (MRI)-guided focused ultrasound (US) is a safe, noninvasive treatment that alleviated pain from bone metastases. However, outcomes varied among institutions (from 0%-100% treatment success). PURPOSE The aim of this study was to identify patient selection, technical treatment, and imaging parameters that predict successful pain relief of osseous metastases after MRI-guided focused US. MATERIALS AND METHODS This was a secondary analysis of a phase 3 clinical study that included participants who received MRI-guided focused US treatment for painful osseous metastases. Noncontrast CT was obtained before treatment. T2-weighted and T1-weighted postcontrast MRIs at 1.5 T or 3 T were obtained before, at the time of, and at 3 months after treatment. Numerical Rating Scale pain scores and morphine equivalent daily dose data were obtained over a 3-month follow-up period. At the 3-month endpoint, participants were categorized as pain relief responders or nonresponders based on Numerical Rating Scale and morphine equivalent daily dose data. Demographics, technical parameters, and imaging features associated with pain relief were determined using stepwise univariable and multivariable models. Responder rates between the subgroup of participants with all predictive parameters and that with none of the parameters were compared using Fisher exact test. RESULTS The analysis included 99 participants (mean age, 59 ± 14 years; 56 women). The 3 variables that predicted successful pain relief were energy density on the bone surface (EDBS) (P = 0.001), the presence of postprocedural periosteal devascularization (black band, BB+) (P = 0.005), and female sex (P = 0.02). The subgroup of participants with BB+ and EDBS greater than 5 J/mm2 had a larger decrease in mean pain score (5.2; 95% confidence interval, 4.6-5.8) compared with those without (BB-, EDBS ≤ 5 J/mm2) (1.1; 95% confidence interval, 0.8-3.0; P < 0.001). Participants with all 3 predictive variables had a pain relief responder rate of 93% compared with 0% in participants having none of the predictive variables (P < 0.001). CONCLUSIONS High EDBS during treatment, postprocedural periosteal devascularization around the tumor site (BB+), and female sex increased the likelihood of pain relief after MRI-guided focused US of osseous metastasis.
Collapse
Affiliation(s)
- Rachel R Bitton
- From the Department of Radiology, Stanford University, Stanford, CA
| | | | | | - Alessandro Napoli
- Department of Radiological Sciences, University of Rome, Rome, Italy
| | - Joshua Meyer
- Department of Radiation Oncology, Fox Chase Cancer Center
| | - Kim Butts Pauly
- From the Department of Radiology, Stanford University, Stanford, CA
| | - Mark Hurwitz
- Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA
| | - Pejman Ghanouni
- From the Department of Radiology, Stanford University, Stanford, CA
| |
Collapse
|
4
|
Kokuryo D, Kumamoto E, Kuroda K. Recent technological advancements in thermometry. Adv Drug Deliv Rev 2020; 163-164:19-39. [PMID: 33217482 DOI: 10.1016/j.addr.2020.11.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2020] [Revised: 07/25/2020] [Accepted: 11/02/2020] [Indexed: 12/12/2022]
Abstract
Thermometry is the key factor for achieving successful thermal therapy. Although invasive thermometry with a probe has been used for more than four decades, this method can only detect the local temperature within the probing volume. Noninvasive temperature imaging using a tomographic technique is ideal for monitoring hot-spot formation in the human body. Among various techniques, such as X-ray computed tomography, microwave tomography, echo sonography, and magnetic resonance (MR) imaging, the proton resonance frequency shift method of MR thermometry is the only method currently available for clinical practice because its temperature sensitivity is consistent in most aqueous tissues and can be easily observed using common clinical scanners. New techniques are being proposed to improve the robustness of this method against tissue motion. MR techniques for fat thermometry were also developed based on relaxation times. One of the latest non-MR techniques to attract attention is photoacoustic imaging.
Collapse
Affiliation(s)
- Daisuke Kokuryo
- Graduate School of System Informatics, Kobe University, Japan
| | - Etsuko Kumamoto
- Information Science and Technology Center, Kobe University, Japan
| | - Kagayaki Kuroda
- School of Information Science and Technology, Tokai University, Japan; Center for Frontier Medical Engineering, Chiba University, Japan.
| |
Collapse
|
5
|
|
6
|
Bitton RR, Webb TD, Pauly KB, Ghanouni P. Prolonged heating in nontargeted tissue during MR‐guided focused ultrasound of bone tumors. J Magn Reson Imaging 2019; 50:1526-1533. [DOI: 10.1002/jmri.26726] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 03/08/2019] [Accepted: 03/10/2019] [Indexed: 12/16/2022] Open
Affiliation(s)
- Rachel R. Bitton
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| | - Taylor D. Webb
- Department of Electrical EngineeringStanford University Stanford California USA
| | - Kim Butts Pauly
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| | - Pejman Ghanouni
- School of Medicine, Department of RadiologyStanford University Stanford California USA
| |
Collapse
|
7
|
Odéen H, Parker DL. Magnetic resonance thermometry and its biological applications - Physical principles and practical considerations. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019; 110:34-61. [PMID: 30803693 PMCID: PMC6662927 DOI: 10.1016/j.pnmrs.2019.01.003] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 01/23/2019] [Indexed: 05/25/2023]
Abstract
Most parameters that influence the magnetic resonance imaging (MRI) signal experience a temperature dependence. The fact that MRI can be used for non-invasive measurements of temperature and temperature change deep inside the human body has been known for over 30 years. Today, MR temperature imaging is widely used to monitor and evaluate thermal therapies such as radio frequency, microwave, laser, and focused ultrasound therapy. In this paper we cover the physical principles underlying the biological applications of MR temperature imaging and discuss practical considerations and remaining challenges. For biological tissue, the MR signal of interest comes mostly from hydrogen protons of water molecules but also from protons in, e.g., adipose tissue and various metabolites. Most of the discussed methods, such as those using the proton resonance frequency (PRF) shift, T1, T2, and diffusion only measure temperature change, but measurements of absolute temperatures are also possible using spectroscopic imaging methods (taking advantage of various metabolite signals as internal references) or various types of contrast agents. Currently, the PRF method is the most used clinically due to good sensitivity, excellent linearity with temperature, and because it is largely independent of tissue type. Because the PRF method does not work in adipose tissues, T1- and T2-based methods have recently gained interest for monitoring temperature change in areas with high fat content such as the breast and abdomen. Absolute temperature measurement methods using spectroscopic imaging and contrast agents often offer too low spatial and temporal resolution for accurate monitoring of ablative thermal procedures, but have shown great promise in monitoring the slower and usually less spatially localized temperature change observed during hyperthermia procedures. Much of the current research effort for ablative procedures is aimed at providing faster measurements, larger field-of-view coverage, simultaneous monitoring in aqueous and adipose tissues, and more motion-insensitive acquisitions for better precision measurements in organs such as the heart, liver, and kidneys. For hyperthermia applications, larger coverage, motion insensitivity, and simultaneous aqueous and adipose monitoring are also important, but great effort is also aimed at solving the problem of long-term field drift which gets interpreted as temperature change when using the PRF method.
Collapse
Affiliation(s)
- Henrik Odéen
- University of Utah, Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, 729 Arapeen Drive, Salt Lake City, UT 84108-1217, USA.
| | - Dennis L Parker
- University of Utah, Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, 729 Arapeen Drive, Salt Lake City, UT 84108-1217, USA.
| |
Collapse
|
8
|
Jerban S, Szeverenyi N, Ma Y, Guo T, Namiranian B, To S, Jang H, Chang EY, Du J. Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature. ACTA ACUST UNITED AC 2019. [DOI: 10.13104/imri.2019.23.3.202] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Saeed Jerban
- Department of Radiology, University of California, San Diego, United States
| | | | - Yajun Ma
- Department of Radiology, University of California, San Diego, United States
| | - Tan Guo
- Department of Radiology, University of California, San Diego, United States
| | - Behnam Namiranian
- Department of Radiology, University of California, San Diego, United States
| | - Sarah To
- Radiology Service, VA San Diego Healthcare System, San Diego, United States
| | - Hyungseok Jang
- Department of Radiology, University of California, San Diego, United States
| | - Eric Y. Chang
- Department of Radiology, University of California, San Diego, United States
- Radiology Service, VA San Diego Healthcare System, San Diego, United States
| | - Jiang Du
- Department of Radiology, University of California, San Diego, United States
| |
Collapse
|
9
|
Modena D, Baragona M, Bošnački D, Breuer BJT, Elevelt A, Maessen RTH, Hilbers PAJ, Ten Eikelder HMM. Modeling the interference between shear and longitudinal waves under high intensity focused ultrasound propagation in bone. Phys Med Biol 2018; 63:235024. [PMID: 30511661 DOI: 10.1088/1361-6560/aaef14] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) is a noninvasive thermal technique that enables rapid heating of a specific area in the human body. Its clinical relevance has been proven for the treatments of soft tissue tumors, like uterine fibroids, and for the treatments of solid tumors in bone. In MR-HIFU treatment, MR-thermometry is used to monitor the temperature evolution in soft tissue. However, this technique is currently unavailable for bone tissue. Computer models can play a key role in the accurate prediction and monitoring of temperature. Here, we present a computer ray tracing model that calculates the heat production density in the focal region. This model accounts for both the propagation of shear waves and the interference between longitudinal and shear waves. The model was first compared with a finite element approach which solves the Helmholtz equation in soft tissue and the frequency-domain wave equation in bone. To obtain the temperature evolution in the focal region, the heat equation was solved using the heat production density generated by the raytracer as a heat source. Then, we investigated the role of the interaction between shear and longitudinal waves in terms of dissipated power and temperature output. The results of our model were in agreement with the results obtained by solving the Helmholtz equation and the frequency-domain wave equation, both in soft tissue and bone. Our results suggest that it is imperative to include both shear waves and their interference with longitudinal waves in the model when simulating high intensity focused ultrasound propagation in solids. In fact, when modeling HIFU treatments, omitting the interference between shear and longitudinal waves leads to an over-estimation of the temperature increase in the tissues.
Collapse
Affiliation(s)
- D Modena
- Eindhoven University of Technology, Eindhoven, Netherlands
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Hudson TJ, Looi T, Pichardo S, Amaral J, Temple M, Drake JM, Waspe AC. Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue. Med Phys 2017; 45:506-519. [DOI: 10.1002/mp.12704] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 11/03/2017] [Accepted: 11/09/2017] [Indexed: 12/23/2022] Open
Affiliation(s)
- Thomas J. Hudson
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Institute of Biomaterials and Biomedical Engineering; University of Toronto; Toronto Ontario M5S 3G9 Canada
| | - Thomas Looi
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Institute of Biomaterials and Biomedical Engineering; University of Toronto; Toronto Ontario M5S 3G9 Canada
| | - Samuel Pichardo
- Thunder Bay Regional Health Research Institute; Thunder Bay Ontario P7B 6V4 Canada
- Electrical Engineering and Physics; Lakehead University; Thunder Bay Ontario P7B 5E1 Canada
| | - Joao Amaral
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Department of Medical Imaging; University of Toronto; Toronto Ontario M5T 1W7 Canada
| | - Michael Temple
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Department of Medical Imaging; University of Toronto; Toronto Ontario M5T 1W7 Canada
| | - James M. Drake
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Institute of Biomaterials and Biomedical Engineering; University of Toronto; Toronto Ontario M5S 3G9 Canada
| | - Adam C. Waspe
- Centre for Image Guided Innovation and Therapeutic Intervention; Hospital for Sick Children; Toronto Ontario M5G 1X8 Canada
- Department of Medical Imaging; University of Toronto; Toronto Ontario M5T 1W7 Canada
| |
Collapse
|
11
|
Kuroda K. MR techniques for guiding high-intensity focused ultrasound (HIFU) treatments. J Magn Reson Imaging 2017; 47:316-331. [PMID: 28580706 DOI: 10.1002/jmri.25770] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Accepted: 05/02/2017] [Indexed: 12/17/2022] Open
Abstract
To make full use of the ability of magnetic resonance (MR) to guide high-intensity focused ultrasound (HIFU) treatment, effort has been made to improve techniques for thermometry, motion tracking, and sound beam visualization. For monitoring rapid temperature elevation with proton resonance frequency (PRF) shift, data acquisition and processing can be accelerated with parallel imaging and/or sparse sampling in conjunction with appropriate signal processing methods. Thermometry should be robust against tissue motion, motion-induced magnetic field variation, and susceptibility change. Thus, multibaseline, referenceless, or hybrid techniques have become important. In cases with adipose or bony tissues, for which PRF shift cannot be used, thermometry with relaxation times or signal intensity may be utilized. Motion tracking is crucial not only for thermometry but also for targeting the focus of an ultrasound in moving organs such as the liver, kidney, or heart. Various techniques for motion tracking, such as those based on an anatomical image atlas with optical-flow displacement detection, a navigator echo to seize the diaphragm position, and/or rapid imaging to track vessel positions, have been proposed. Techniques for avoiding the ribcage and near-field heating have also been examined. MR acoustic radiation force imaging (MR-ARFI) is an alternative to thermometry that can identify the location and shape of the focal spot and sound beam path. This technique could be useful for treating heterogeneous tissue regions or performing transcranial therapy. All of these developments, which will be discussed further in this review, expand the applicability of HIFU treatments to a variety of clinical targets while maintaining safety and precision. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018;47:316-331.
Collapse
Affiliation(s)
- Kagayaki Kuroda
- Department of Human and Information Science, School of Information Science and Technology, Tokai University, Hiratsuka, Kanagawa, Japan.,Center for Frontier Medical Engineering, Chiba University, Inage, Chiba, Japan
| |
Collapse
|
12
|
Ozhinsky E, Han M, Bucknor M, Krug R, Rieke V. T2-based temperature monitoring in bone marrow for MR-guided focused ultrasound. J Ther Ultrasound 2016; 4:26. [PMID: 27882240 PMCID: PMC5112680 DOI: 10.1186/s40349-016-0073-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 10/03/2016] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Current clinical protocols for MR-guided focused ultrasound (MRgFUS) treatment of osseous lesions, including painful bone metastases and osteoid osteomas, rely on measurement of the temperature change in adjacent muscle to estimate the temperature of the bone. The goal of this study was to determine if T2-based thermometry could be used to monitor the temperature change in bone marrow during focused ultrasound ablation of bone lesions. METHODS We investigated the dependence of T2 on temperature in ex vivo bovine yellow bone marrow at 3T and studied the influence of acquisition parameters on the T2 measurements. We examined if T2 changes in red bone marrow caused by the ablation of ex vivo trabecular bone were reversible and measured the patterns of heating and tissue damage. The technique was validated during the ablation of intact ex vivo bone samples and an in vivo animal model. RESULTS Results of the calibration experiment showed a linear relationship (7 ms/°C) between T2 change and temperature and could be used to quantify the temperature during heating of up to 60 °C. During trabecular bone ablation, we observed a linear relationship (5.7 ms per °C) between T2 and temperature during the heating stage of the experiment. After cool down, there was residual T2 elevation (~35 ms) in the ablated area suggesting irreversible tissue changes. In ex vivo and in vivo cortical bone ablation experiments, we observed an increase in T2 values in the marrow adjacent to the intersection of the cortical bone and the beam path. The in vivo experiment showed excellent correspondence between the area of T2 elevation in marrow during the ablation and the resulting non-enhancing area in the post-contrast images. CONCLUSIONS In this study, we have demonstrated that T2-based thermometry can be used in vivo to measure the heating in the marrow during bone ablation. The ability to monitor the temperature within the bone marrow allowed more complete visualization of the heat distribution into the bone, which is important for local lesion control.
Collapse
Affiliation(s)
- Eugene Ozhinsky
- Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, Box 0946, San Francisco, CA 94107 USA
| | - Misung Han
- Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, Box 0946, San Francisco, CA 94107 USA
| | - Matthew Bucknor
- Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, Box 0946, San Francisco, CA 94107 USA
| | - Roland Krug
- Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, Box 0946, San Francisco, CA 94107 USA
| | - Viola Rieke
- Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, Box 0946, San Francisco, CA 94107 USA
| |
Collapse
|
13
|
Wardlow R, Bing C, VanOsdol J, Maples D, Ladouceur-Wodzak M, Harbeson M, Nofiele J, Staruch R, Ramachandran A, Malayer J, Chopra R, Ranjan A. Targeted antibiotic delivery using low temperature-sensitive liposomes and magnetic resonance-guided high-intensity focused ultrasound hyperthermia. Int J Hyperthermia 2016; 32:254-64. [PMID: 26892114 PMCID: PMC6029942 DOI: 10.3109/02656736.2015.1134818] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Chronic non-healing wound infections require long duration antibiotic therapy, and are associated with significant morbidity and health-care costs. Novel approaches for efficient, readily-translatable targeted and localised antimicrobial delivery are needed. The objectives of this study were to 1) develop low temperature-sensitive liposomes (LTSLs) containing an antimicrobial agent (ciprofloxacin) for induced release at mild hyperthermia (∼42 °C), 2) characterise in vitro ciprofloxacin release, and efficacy against Staphylococcus aureus plankton and biofilms, and 3) determine the feasibility of localised ciprofloxacin delivery in combination with MR-HIFU hyperthermia in a rat model. LTSLs were loaded actively with ciprofloxacin and their efficacy was determined using a disc diffusion method, MBEC biofilm device, and scanning electron microscopy (SEM). Ciprofloxacin release from LTSLs was assessed in a physiological buffer by fluorescence spectroscopy, and in vivo in a rat model using MR-HIFU. Results indicated that < 5% ciprofloxacin was released from the LTSL at body temperature (37 °C), while >95% was released at 42 °C. Precise hyperthermia exposures in the thigh of rats using MR-HIFU during intravenous (i.v.) administration of the LTSLs resulted in a four fold greater local concentration of ciprofloxacin compared to controls (free ciprofloxacin + MR-HIFU or LTSL alone). The biodistribution of ciprofloxacin in unheated tissues was fairly similar between treatment groups. Triggered release at 42 °C from LTSL achieved significantly greater S. aureus killing and induced membrane deformation and changes in biofilm matrix compared to free ciprofloxacin or LTSL at 37 °C. This technique has potential as a method to deliver high concentration antimicrobials to chronic wounds.
Collapse
Affiliation(s)
- Rachel Wardlow
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| | - Chenchen Bing
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Joshua VanOsdol
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| | - Danny Maples
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| | | | - Michele Harbeson
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| | - Joris Nofiele
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Robert Staruch
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
- Clinical Sites Research Program, Philips Research, Briarcliff Manor, NY
| | | | - Jerry Malayer
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| | - Rajiv Chopra
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX
| | - Ashish Ranjan
- Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK, USA
| |
Collapse
|
14
|
ten Eikelder HMM, Bošnački D, Elevelt A, Donato K, Di Tullio A, Breuer BJT, van Wijk JH, van Dijk EVM, Modena D, Yeo SY, Grüll H. Modelling the temperature evolution of bone under high intensity focused ultrasound. Phys Med Biol 2016; 61:1810-28. [PMID: 26854572 DOI: 10.1088/0031-9155/61/4/1810] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) has been clinically shown to be effective for palliative pain management in patients suffering from skeletal metastasis. The underlying mechanism is supposed to be periosteal denervation caused by ablative temperatures reached through ultrasound heating of the cortex. The challenge is exact temperature control during sonication as MR-based thermometry approaches for bone tissue are currently not available. Thus, in contrast to the MR-HIFU ablation of soft tissue, a thermometry feedback to the HIFU is lacking, and the treatment of bone metastasis is entirely based on temperature information acquired in the soft tissue adjacent to the bone surface. However, heating of the adjacent tissue depends on the exact sonication protocol and requires extensive modelling to estimate the actual temperature of the cortex. Here we develop a computational model to calculate the spatial temperature evolution in bone and the adjacent tissue during sonication. First, a ray-tracing technique is used to compute the heat production in each spatial point serving as a source term for the second part, where the actual temperature is calculated as a function of space and time by solving the Pennes bio-heat equation. Importantly, our model includes shear waves that arise at the bone interface as well as all geometrical considerations of transducer and bone geometry. The model was compared with a theoretical approach based on the far field approximation and an MR-HIFU experiment using a bone phantom. Furthermore, we investigated the contribution of shear waves to the heat production and resulting temperatures in bone. The temperature evolution predicted by our model was in accordance with the far field approximation and agreed well with the experimental data obtained in phantoms. Our model allows the simulation of the HIFU treatments of bone metastasis in patients and can be extended to a planning tool prior to MR-HIFU treatments.
Collapse
|
15
|
Bazzocchi A, Napoli A, Sacconi B, Battista G, Guglielmi G, Catalano C, Albisinni U. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics. Br J Radiol 2015; 89:20150358. [PMID: 26607640 DOI: 10.1259/bjr.20150358] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a "new" interventional technique and on its applications for MSK and allied sciences.
Collapse
Affiliation(s)
- Alberto Bazzocchi
- 1 Diagnostic and Interventional Radiology, The "Rizzoli" Orthopaedic Institute, Bologna, Italy
| | - Alessandro Napoli
- 2 Department of Radiology, Sapienza University of Rome, Umberto I Hospital, Rome, Italy
| | - Beatrice Sacconi
- 2 Department of Radiology, Sapienza University of Rome, Umberto I Hospital, Rome, Italy
| | - Giuseppe Battista
- 3 Department of Specialized, Diagnostic, and Experimental Medicine, University of Bologna, Sant'Orsola-Malpighi Hospital, Bologna, Italy
| | - Giuseppe Guglielmi
- 4 Department of Radiology, University of Foggia, Foggia, Italy.,5 Department of Radiology, Scientific Institute "Casa Sollievo della Sofferenza" Hospital, Foggia, Italy
| | - Carlo Catalano
- 2 Department of Radiology, Sapienza University of Rome, Umberto I Hospital, Rome, Italy
| | - Ugo Albisinni
- 1 Diagnostic and Interventional Radiology, The "Rizzoli" Orthopaedic Institute, Bologna, Italy
| |
Collapse
|
16
|
Han M, Rieke V, Scott SJ, Ozhinsky E, Salgaonkar VA, Jones PD, Larson PEZ, Diederich CJ, Krug R. Quantifying temperature-dependent T1 changes in cortical bone using ultrashort echo-time MRI. Magn Reson Med 2015; 74:1548-55. [PMID: 26390357 DOI: 10.1002/mrm.25994] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 08/05/2015] [Accepted: 08/30/2015] [Indexed: 11/06/2022]
Abstract
PURPOSE To demonstrate the feasibility of using ultrashort echo-time MRI to quantify T1 changes in cortical bone due to heating. METHODS Variable flip-angle T1 mapping combined with 3D ultrashort echo-time imaging was used to measure T1 in cortical bone. A calibration experiment was performed to detect T1 changes with temperature in ex vivo cortical bone samples from a bovine femur. Ultrasound heating experiments were performed using an interstitial applicator in ex vivo bovine femur specimens, and heat-induced T1 changes were quantified. RESULTS The calibration experiment demonstrated that T1 increases with temperature in cortical bone. We observed a linear relationship between temperature and T1 with a linear coefficient between 0.67 and 0.84 ms/°C over a range of 25-70°C. The ultrasound heating experiments showed increased T1 changes in the heated regions, and the relationship between the temperature changes and T1 changes was similar to that of the calibration. CONCLUSION We demonstrated a temperature dependence of T1 in ex vivo cortical bone using a variable flip-angle ultrashort echo-time T1 mapping method.
Collapse
Affiliation(s)
- Misung Han
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| | - Viola Rieke
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| | - Serena J Scott
- Department of Radiation Oncology, University of California, San Francisco, San Francisco, California, USA
| | - Eugene Ozhinsky
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| | - Vasant A Salgaonkar
- Department of Radiation Oncology, University of California, San Francisco, San Francisco, California, USA
| | - Peter D Jones
- Department of Radiation Oncology, University of California, San Francisco, San Francisco, California, USA
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA.,Joint Graduate Program in Bioengineering, University of California San Francisco/Berkeley, San Francisco, California, USA
| | - Chris J Diederich
- Department of Radiation Oncology, University of California, San Francisco, San Francisco, California, USA.,Joint Graduate Program in Bioengineering, University of California San Francisco/Berkeley, San Francisco, California, USA
| | - Roland Krug
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California, USA
| |
Collapse
|
17
|
Lam MK, Huisman M, Nijenhuis RJ, van den Bosch MAAJ, Viergever MA, Moonen CTW, Bartels LW. Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases. J Ther Ultrasound 2015; 3:5. [PMID: 25874113 PMCID: PMC4396149 DOI: 10.1186/s40349-015-0026-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Accepted: 03/07/2015] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of signal-to-noise ratio (SNR) and apparent temperature variation. Also, MRT artifacts were scored for their occurrence and hampering of the treatment monitoring. METHODS Analyses were performed on 224 MRT datasets retrieved from 13 treatments. The SNR was measured per voxel over time in magnitude images, in the target lesion and surrounding muscle, and was averaged per treatment. The standard deviation over time of the measured temperature per voxel in MRT images, in the muscle outside the heated region, was defined as the apparent temperature variation and was averaged per treatment. The scored MRT artifacts originated from the following sources: respiratory and non-respiratory time-varying field inhomogeneities, arterial ghosting, and patient motion by muscle contraction and by gross body movement. Distinction was made between lesion type, location, and procedural sedation and analgesic (PSA). RESULTS The average SNR was highest in and around osteolytic lesions (21 in lesions, 27 in surrounding muscle, n = 4) and lowest in the upper body (9 in lesions, 16 in surrounding muscle, n = 4). The average apparent temperature variation was lowest in osteolytic lesions (1.2°C, n = 4) and the highest in the upper body (1.7°C, n = 4). Respiratory time-varying field inhomogeneity MRT artifacts occurred in 85% of the datasets and hampered treatment monitoring in 81%. Non-respiratory time-varying field inhomogeneities and arterial ghosting MRT artifacts were most frequent (94% and 95%) but occurred only locally. Patient motion artifacts were highly variable and occurred less in treatments of osteolytic lesions and using propofol and esketamine as PSA. CONCLUSIONS In this study, the general image quality of MRT was observed to be higher in osteolytic lesions and lower in the upper body. Respiratory time-varying field inhomogeneity was the most prominent MRT artifact. Patient motion occurrence varied between treatments and seemed to be related to lesion type and type of PSA. Clinicians should be aware of these observed characteristics when interpreting MRT images.
Collapse
Affiliation(s)
- Mie K Lam
- />Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Merel Huisman
- />Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Robbert J Nijenhuis
- />Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Max A Viergever
- />Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Chrit TW Moonen
- />Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Lambertus W Bartels
- />Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|