1
|
Oliveira DR, da Costa ET, Schenberg LA, Ducati LC, do Lago CL. 13 C NMR as an analytical tool for the detection of carbonic acid and pK a determination. MAGNETIC RESONANCE IN CHEMISTRY : MRC 2024; 62:114-120. [PMID: 38258899 DOI: 10.1002/mrc.5430] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 12/27/2023] [Accepted: 01/01/2024] [Indexed: 01/24/2024]
Abstract
NMR spectroscopy has become a standard technique in studies both on carbon capture and storage. 13 C NMR allows the detection of two peaks for carbonated aqueous samples: one for CO2(aq) and another one for the species H2 CO3 , HCO3 - , and CO3 2- -herein collectively named Hx CO3 x-2 . The chemical shift of this second peak depends on the molar fraction of the three species in equilibrium and has been used to assess the equilibrium between HCO3 - and CO3 2- . The detection of H2 CO3 at low pH solutions is hindered, because of the concurrent liberation of CO2 when the medium is acidified. Herein, a valved NMR tube facilitates the detection of the Hx CO3 x-2 peak across a wide pH range, even at pH 1.8 where the dominant species is H2 CO3 . The method employed the formation of frozen layers of NaH13 CO3 and acid solutions within the tube, which are mixed as the tube reaches room temperature. At this point, the tube is already securely sealed, preventing any loss of CO2 to the atmosphere. A spectrophotometry approach allowed the measurement of the actual pH inside the pressurized NMR tube. The chemical shift for H2 CO3 was determined as 160.33 ± 0.03 ppm, which is in good agreement with value obtained by DFT calculations combined with Car-Parrinello molecular dynamics. The H2 CO3 pKa value determined by the present method was 3.41 ± 0.03, for 15% D2 O aqueous medium and 0.8 mol/L ionic strength. The proposed method can be extended to studies about analogs such as alkyl carbonic and carbamic acids.
Collapse
Affiliation(s)
- Daniel Rossado Oliveira
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, State of São Paulo, Brazil
| | - Eric Tavares da Costa
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, State of São Paulo, Brazil
| | - Leonardo Araujo Schenberg
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, State of São Paulo, Brazil
| | - Lucas Colucci Ducati
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, State of São Paulo, Brazil
| | - Claudimir Lucio do Lago
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo, State of São Paulo, Brazil
| |
Collapse
|
2
|
Wodtke P, Grashei M, Schilling F. Quo Vadis Hyperpolarized 13C MRI? Z Med Phys 2023:S0939-3889(23)00120-4. [PMID: 38160135 DOI: 10.1016/j.zemedi.2023.10.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/16/2023] [Accepted: 10/20/2023] [Indexed: 01/03/2024]
Abstract
Over the last two decades, hyperpolarized 13C MRI has gained significance in both preclinical and clinical studies, hereby relying on technologies like PHIP-SAH (ParaHydrogen-Induced Polarization-Side Arm Hydrogenation), SABRE (Signal Amplification by Reversible Exchange), and dDNP (dissolution Dynamic Nuclear Polarization), with dDNP being applied in humans. A clinical dDNP polarizer has enabled studies across 24 sites, despite challenges like high cost and slow polarization. Parahydrogen-based techniques like SABRE and PHIP offer faster, more cost-efficient alternatives but require molecule-specific optimization. The focus has been on imaging metabolism of hyperpolarized probes, which requires long T1, high polarization and rapid contrast generation. Efforts to establish novel probes, improve acquisition techniques and enhance data analysis methods including artificial intelligence are ongoing. Potential clinical value of hyperpolarized 13C MRI was demonstrated primarily for treatment response assessment in oncology, but also in cardiology, nephrology, hepatology and CNS characterization. In this review on biomedical hyperpolarized 13C MRI, we summarize important and recent advances in polarization techniques, probe development, acquisition and analysis methods as well as clinical trials. Starting from those we try to sketch a trajectory where the field of biomedical hyperpolarized 13C MRI might go.
Collapse
Affiliation(s)
- Pascal Wodtke
- Department of Nuclear Medicine, TUM School of Medicine and Health, Klinikum rechts der Isar of Technical University of Munich, 81675 Munich, Germany; Department of Radiology, University of Cambridge, Cambridge CB2 0QQ, United Kingdom; Cancer Research UK Cambridge Centre, University of Cambridge, Cambridge UK
| | - Martin Grashei
- Department of Nuclear Medicine, TUM School of Medicine and Health, Klinikum rechts der Isar of Technical University of Munich, 81675 Munich, Germany
| | - Franz Schilling
- Department of Nuclear Medicine, TUM School of Medicine and Health, Klinikum rechts der Isar of Technical University of Munich, 81675 Munich, Germany; Munich Institute of Biomedical Engineering, Technical University of Munich, 85748 Garching, Germany; German Cancer Consortium (DKTK), Partner Site Munich and German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg 69120, Germany.
| |
Collapse
|
3
|
Mu C, Liu X, Kim Y, Riselli A, Korenchan DE, Bok RA, Delos Santos R, Sriram R, Qin H, Nguyen H, Gordon JW, Slater J, Larson PEZ, Vigneron DB, Kurhanewicz J, Wilson DM, Flavell RR. Clinically Translatable Hyperpolarized 13C Bicarbonate pH Imaging Method for Use in Prostate Cancer. ACS Sens 2023; 8:4042-4054. [PMID: 37878761 PMCID: PMC10683509 DOI: 10.1021/acssensors.3c00851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 09/20/2023] [Accepted: 09/25/2023] [Indexed: 10/27/2023]
Abstract
Solid tumors such as prostate cancer (PCa) commonly develop an acidic microenvironment with pH 6.5-7.2, owing to heterogeneous perfusion, high metabolic activity, and rapid cell proliferation. In preclinical prostate cancer models, disease progression is associated with a decrease in tumor extracellular pH, suggesting that pH imaging may reflect an imaging biomarker to detect aggressive and high-risk disease. Therefore, we developed a hyperpolarized carbon-13 MRI method to image the tumor extracellular pH (pHe) and prepared it for clinical translation for detection and risk stratification of PCa. This method relies on the rapid breakdown of hyperpolarized (HP) 1,2-glycerol carbonate (carbonyl-13C) via base-catalyzed hydrolysis to produce HP 13CO32-, which is neutralized and converted to HP H13CO3-. After injection, HP H13CO3- equilibrates with HP 13CO2 in vivo and enables the imaging of pHe. Using insights gleaned from mechanistic studies performed in the hyperpolarized state, we solved issues of polarization loss during preparation in a clinical polarizer system. We successfully customized a reaction apparatus suitable for clinical application, developed clinical standard operating procedures, and validated the radiofrequency pulse sequence and imaging data acquisition with a wide range of animal models. The results demonstrated that we can routinely produce a highly polarized and safe HP H13CO3- contrast agent suitable for human injection. Preclinical imaging studies validated the reliability and accuracy of measuring acidification in healthy kidney and prostate tumor tissue. These methods were used to support an Investigational New Drug application to the U.S. Food and Drug Administration. This methodology is now ready to be implemented in human trials, with the ultimate goal of improving the management of PCa.
Collapse
Affiliation(s)
- Changhua Mu
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Xiaoxi Liu
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Yaewon Kim
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Andrew Riselli
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - David E. Korenchan
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Robert A. Bok
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Romelyn Delos Santos
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Renuka Sriram
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Hecong Qin
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Hao Nguyen
- Department
of Urology, University of California, San Francisco, California 94143, United States
| | - Jeremy W. Gordon
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - James Slater
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Peder E. Z. Larson
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Daniel B. Vigneron
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - John Kurhanewicz
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - David M. Wilson
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
| | - Robert R. Flavell
- Department
of Radiology and Biomedical Imaging, University
of California, San Francisco, San Francisco, California 94107, United States
- Department
of Pharmaceutical Chemistry, University
of California, San Francisco, California 94158, United States
| |
Collapse
|
4
|
Tumor Microenvironment Biosensors for Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopy. Mol Imaging Biol 2021; 23:323-334. [PMID: 33415679 DOI: 10.1007/s11307-020-01570-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 11/12/2020] [Accepted: 12/01/2020] [Indexed: 02/07/2023]
Abstract
Hyperpolarization (HP) of a carbon-13 molecule via dynamic nuclear polarization (DNP) involves polarization at low temperature, followed by a dissolution procedure producing a solution with highly polarized spins at room temperature. This dissolution DNP method significantly increases the signal-to-noise ratio (SNR) of nuclear magnetic resonance (NMR) over 10,000-fold and facilitates the use of magnetic resonance spectroscopy (MRS) to image not only metabolism but also the extracellular microenvironment. The extracellular tumor microenvironment (TME) closely interacts with tumor cells and stimulates their growth and metastasis. Thus, the ability to detect pathological changes in the TME is pivotal for the detection and study of cancers. This review highlights the potential use of MRS to study features of the TME-elevated export of lactate, reduced interstitial pH, imbalanced redox equilibrium, and altered metal homeostasis. The promising outcomes of both in vitro and in vivo assays suggest that DNP-MRS may be a useful technique to study aspects of the TME. With continued improvements, this tool has the potential to study the TME and provide guidance for accurate patient stratification and precise personal therapy. Graphical Abstract.
Collapse
|
5
|
Chen J, Hackett EP, Singh J, Kovács Z, Park JM. Simultaneous Assessment of Intracellular and Extracellular pH Using Hyperpolarized [1- 13C]Alanine Ethyl Ester. Anal Chem 2020; 92:11681-11686. [PMID: 32786486 DOI: 10.1021/acs.analchem.0c01568] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Tissue pH is tightly regulated in vivo, being a sensitive physiological biomarker. Advent of dissolution dynamic nuclear polarization (DNP) and its translation to humans stimulated development of pH-sensitive agents. However, requirements of DNP probes such as biocompatibility, signal sensitivity, and spin-lattice relaxation time (T1) complicate in vivo translation of the agents. Here, we developed a 13C-labeled alanine derivative, [1-13C]-l-alanine ethyl ester, as a viable DNP probe whose chemical shift is sensitive to the physiological pH range, and demonstrated the feasibility in phantoms and rat livers in vivo. Alanine ethyl ester readily crosses cell membrane while simultaneously assessing extracellular and intracellular pH in vivo. Following cell transport, [1-13C]-l-alanine ethyl ester is instantaneously hydrolyzed to [1-13C]-l-alanine, and subsequently metabolized to [1-13C]lactate and [13C]bicarbonate. The pH-insensitive alanine resonance was used as a reference.
Collapse
Affiliation(s)
- Jun Chen
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States
| | - Edward P Hackett
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States
| | - Jaspal Singh
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States
| | - Zoltán Kovács
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States
| | - Jae Mo Park
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States.,Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas 75390-8568, United States.,Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, Texas 75080, United States
| |
Collapse
|
6
|
Spatiotemporal pH Heterogeneity as a Promoter of Cancer Progression and Therapeutic Resistance. Cancers (Basel) 2019; 11:cancers11071026. [PMID: 31330859 PMCID: PMC6678451 DOI: 10.3390/cancers11071026] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 07/17/2019] [Accepted: 07/18/2019] [Indexed: 12/15/2022] Open
Abstract
Dysregulation of pH in solid tumors is a hallmark of cancer. In recent years, the role of altered pH heterogeneity in space, between benign and aggressive tissues, between individual cancer cells, and between subcellular compartments, has been steadily elucidated. Changes in temporal pH-related processes on both fast and slow time scales, including altered kinetics of bicarbonate-CO2 exchange and its effects on pH buffering and gradual, progressive changes driven by changes in metabolism, are further implicated in phenotypic changes observed in cancers. These discoveries have been driven by advances in imaging technologies. This review provides an overview of intra- and extracellular pH alterations in time and space reflected in cancer cells, as well as the available technology to study pH spatiotemporal heterogeneity.
Collapse
|
7
|
Korenchan DE, Gordon JW, Subramaniam S, Sriram R, Baligand C, VanCriekinge M, Bok R, Vigneron DB, Wilson DM, Larson PEZ, Kurhanewicz J, Flavell RR. Using bidirectional chemical exchange for improved hyperpolarized [ 13 C]bicarbonate pH imaging. Magn Reson Med 2019; 82:959-972. [PMID: 31050049 DOI: 10.1002/mrm.27780] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 03/29/2019] [Accepted: 04/01/2019] [Indexed: 12/18/2022]
Abstract
PURPOSE Rapid chemical exchange can affect SNR and pH measurement accuracy for hyperpolarized pH imaging with [13 C]bicarbonate. The purpose of this work was to investigate chemical exchange effects on hyperpolarized imaging sequences to identify optimal sequence parameters for high SNR and pH accuracy. METHODS Simulations were performed under varying rates of bicarbonate-CO2 chemical exchange to analyze exchange effects on pH quantification accuracy and SNR under different sampling schemes. Four pulse sequences, including 1 new technique, a multiple-excitation 2D EPI (multi-EPI) sequence, were compared in phantoms using hyperpolarized [13 C]bicarbonate, varying parameters such as tip angles, repetition time, order of metabolite excitation, and refocusing pulse design. In vivo hyperpolarized bicarbonate-CO2 exchange measurements were made in transgenic murine prostate tumors to select in vivo imaging parameters. RESULTS Modeling of bicarbonate-CO2 exchange identified a multiple-excitation scheme for increasing CO2 SNR by up to a factor of 2.7. When implemented in phantom imaging experiments, these sampling schemes were confirmed to yield high pH accuracy and SNR gains. Based on measured bicarbonate-CO2 exchange in vivo, a 47% CO2 SNR gain is predicted. CONCLUSION The novel multi-EPI pulse sequence can boost CO2 imaging signal in hyperpolarized 13 C bicarbonate imaging while introducing minimal pH bias, helping to surmount a major hurdle in hyperpolarized pH imaging.
Collapse
Affiliation(s)
- David E Korenchan
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Jeremy W Gordon
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Sukumar Subramaniam
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Renuka Sriram
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Celine Baligand
- Molecular Imaging Research Center, French Alternative Energies and Atomic Energy Commission Fontenay-aux-Roses, France
| | - Mark VanCriekinge
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Robert Bok
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Daniel B Vigneron
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California.,UC Berkeley, UCSF Graduate Program in Bioengineering, University of California, University of California, San Francisco, Berkeley, California
| | - David M Wilson
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| | - Peder E Z Larson
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California.,UC Berkeley, UCSF Graduate Program in Bioengineering, University of California, University of California, San Francisco, Berkeley, California
| | - John Kurhanewicz
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California.,UC Berkeley, UCSF Graduate Program in Bioengineering, University of California, University of California, San Francisco, Berkeley, California
| | - Robert R Flavell
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California
| |
Collapse
|
8
|
Steinhauser J, Wespi P, Kwiatkowski G, Kozerke S. Production of highly polarized [1- 13 C]acetate by rapid decarboxylation of [2- 13 C]pyruvate - application to hyperpolarized cardiac spectroscopy and imaging. Magn Reson Med 2019; 82:1140-1149. [PMID: 31045272 DOI: 10.1002/mrm.27782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/27/2019] [Accepted: 04/03/2019] [Indexed: 11/10/2022]
Abstract
PURPOSE The objective of the present work was to develop and implement an efficient approach to hyperpolarize [1-13 C]acetate and apply it to in vivo cardiac spectroscopy and imaging. METHODS Rapid hydrogen peroxide induced decarboxylation was used to convert hyperpolarized [2-13 C]pyruvate into highly polarized [1-13 C]acetate employing an additional step following rapid dissolution of [2-13 C]pyruvate in a home-built multi-sample dissolution dynamic nuclear polarization system. Phantom dissolution experiments were conducted to determine optimal parameters of the decarboxylation reaction, retaining polarization and T1 of [1-13 C]acetate. In vivo feasibility of detecting [1-13 C]acetate metabolism is demonstrated using slice-selective spectroscopy and multi-echo imaging of [1-13 C]acetate and [1-13 C]acetylcarnitine in the healthy rat heart. RESULTS The first in vivo signal was observed ~23 s after dissolution. At the corresponding time point in the phantom experiments, 97.9 ± 0.4% of [2-13 C]pyruvate were converted into [1-13 C]acetate by the decarboxylation reaction. T1 and polarization of [1-13 C]acetate was determined to be 29.7 ± 1.9% and a 47.7 ± 0.5 s. Polarization levels of [2-13 C]pyruvate and [1-13 C]acetate were not significantly different after transfer to the scanner. In vivo, [1-13 C]acetate and [1-13 C]acetylcarnitine could be detected using spectroscopy and imaging. CONCLUSION Decarboxylation of hyperpolarized [2-13 C]pyruvate enables the efficient production of highly polarized [1-13 C]acetate that is applicable to study short-chain fatty acid metabolism in the in vivo heart.
Collapse
Affiliation(s)
- Jonas Steinhauser
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Patrick Wespi
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Grzegorz Kwiatkowski
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| |
Collapse
|
9
|
Maptue N, Jiang W, Harrison C, Funk AM, Sharma G, Malloy CR, Sherry D, Khemtong C. Esterase-Catalyzed Production of Hyperpolarized 13C-Enriched Carbon Dioxide in Tissues for Measuring pH. ACS Sens 2018; 3:2232-2236. [PMID: 30398335 DOI: 10.1021/acssensors.8b01097] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
13C Magnetic resonance imaging of hyperpolarized (HP) 13C-enriched bicarbonate (H13CO3-) and carbon dioxide (13CO2) is a novel and sensitive technique for tissue pH mapping in vivo. Administration of the HP physiological buffer pair is attractive, but poor polarization and the short T1 of 13C-enriched inorganic bicarbonate salts are major drawbacks for this approach. Here, we report a new class of mixed anhydrides for esterase-catalyzed production of highly polarized 13CO2 and H13CO3- in tissue. A series of precursors with different alkoxy and acyl groups were synthesized and tested for chemical stability and T1. 13C-enriched ethyl acetyl carbonate (13C-EAC) was found to be the most suitable candidate due to the relatively long T1 and good chemical stability. Our results showed that 13C-EAC can be efficiently and rapidly polarized using BDPA. HP 13C-EAC was rapidly hydrolyzed by esterase to 13C-enriched monoacetyl carbonate (13C-MAC), which then decomposed to HP 13CO2. Equilibrium between the newly produced 13CO2 and H13CO3- was quickly established by carbonic anhydrase, producing a physiological buffer pair with 13C NMR signals that can be quantified for pH measurements. Finally, in vivo tissue pH measurements using HP 13C-EAC was successfully demonstrated in the liver of healthy rats. These results suggest that HP 13C-EAC is a novel imaging probe for in vivo pH measurements.
Collapse
Affiliation(s)
| | | | | | | | | | - Craig R. Malloy
- Veteran Affairs North Texas Health Care System, Dallas, Texas 75216, United States
| | - Dean Sherry
- Department of Chemistry, University of Texas at Dallas, Richardson, Texas 75080, United States
| | | |
Collapse
|
10
|
Martínez-Santiesteban FM, Dang TP, Lim H, Chen AP, Scholl TJ. T 1 nuclear magnetic relaxation dispersion of hyperpolarized sodium and cesium hydrogencarbonate- 13 C. NMR IN BIOMEDICINE 2017; 30:e3749. [PMID: 28653507 DOI: 10.1002/nbm.3749] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2016] [Revised: 04/12/2017] [Accepted: 04/16/2017] [Indexed: 06/07/2023]
Abstract
In vivo pH mapping in tissue using hyperpolarized hydrogencarbonate-13 C has been proposed as a method to study tumor growth and treatment and other pathological conditions related to pH changes. The finite spin-lattice relaxation times (T1 ) of hyperpolarized media are a significant limiting factor for in vivo imaging. Relaxation times can be measured at standard magnetic fields (1.5 T, 3.0 T etc.), but no such data are available at low fields, where T1 values can be significantly shorter. This information is required to determine the potential loss of polarization as the agent is dispensed and transported from the polarizer to the MRI scanner. The purpose of this study is to measure T1 dispersion from low to clinical magnetic fields (0.4 mT to 3.0 T) of different hyperpolarized hydrogencarbonate formulations previously proposed in the literature for in vivo pH measurements. 13 C-enriched cesium and sodium hydrogencarbonate preparations were hyperpolarized using dynamic nuclear polarization, and the T1 values of different samples were measured at different magnetic field strengths using a fast field-cycling relaxometer and a 3.0 T clinical MRI system. The effects of deuterium oxide as a dissolution medium for sodium hydrogencarbonate were also analyzed. This study finds that the cesium formulation has slightly shorter T1 values compared with the sodium preparation. However, the higher solubility of cesium hydrogencarbonate-13 C means it can be polarized at greater concentration, using less trityl radical than sodium hydrogencarbonate-13 C. This study also establishes that the preparation and handling of sodium hydrogencarbonate formulations in relation to cesium hydrogencarbonate is more difficult, due to the higher viscosity and lower achievable concentrations, and that deuterium oxide significantly increases the T1 of sodium hydrogencarbonate solutions. Finally, this work also investigates the influence of pH on the spin-lattice relaxation of cesium hydrogencarbonate-13 C measured over a pH range of 7 to 9 at 0.47 T.
Collapse
Affiliation(s)
| | - Thien Phuoc Dang
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | - Heeseung Lim
- Department of Medical Biophysics, Western University, London, Ontario, Canada
| | | | - Timothy J Scholl
- Department of Medical Biophysics, Western University, London, Ontario, Canada
- Robarts Research Institute, Western University, London, Ontario, Canada
| |
Collapse
|
11
|
Hundshammer C, Düwel S, Schilling F. Imaging of Extracellular pH Using Hyperpolarized Molecules. Isr J Chem 2017. [DOI: 10.1002/ijch.201700017] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Christian Hundshammer
- Department of Nuclear Medicine, Klinikum rechts der Isar; Technical University of Munich; Ismaninger Str. 22 81675 München Germany
- Department of Chemistry; Technical University of Munich; Lichtenbergstr. 2 85748 Garching Germany
| | - Stephan Düwel
- Department of Nuclear Medicine, Klinikum rechts der Isar; Technical University of Munich; Ismaninger Str. 22 81675 München Germany
- Department of Chemistry; Technical University of Munich; Lichtenbergstr. 2 85748 Garching Germany
- Institute of Medical Engineering; Technical University of Munich; Boltzmannstr. 11 85748 Garching Germany
| | - Franz Schilling
- Department of Nuclear Medicine, Klinikum rechts der Isar; Technical University of Munich; Ismaninger Str. 22 81675 München Germany
| |
Collapse
|
12
|
Adamson EB, Ludwig KD, Mummy DG, Fain SB. Magnetic resonance imaging with hyperpolarized agents: methods and applications. Phys Med Biol 2017; 62:R81-R123. [PMID: 28384123 DOI: 10.1088/1361-6560/aa6be8] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
In the past decade, hyperpolarized (HP) contrast agents have been under active development for MRI applications to address the twin challenges of functional and quantitative imaging. Both HP helium (3He) and xenon (129Xe) gases have reached the stage where they are under study in clinical research. HP 129Xe, in particular, is poised for larger scale clinical research to investigate asthma, chronic obstructive pulmonary disease, and fibrotic lung diseases. With advances in polarizer technology and unique capabilities for imaging of 129Xe gas exchange into lung tissue and blood, HP 129Xe MRI is attracting new attention. In parallel, HP 13C and 15N MRI methods have steadily advanced in a wide range of pre-clinical research applications for imaging metabolism in various cancers and cardiac disease. The HP [1-13C] pyruvate MRI technique, in particular, has undergone phase I trials in prostate cancer and is poised for investigational new drug trials at multiple institutions in cancer and cardiac applications. This review treats the methodology behind both HP gases and HP 13C and 15N liquid state agents. Gas and liquid phase HP agents share similar technologies for achieving non-equilibrium polarization outside the field of the MRI scanner, strategies for image data acquisition, and translational challenges in moving from pre-clinical to clinical research. To cover the wide array of methods and applications, this review is organized by numerical section into (1) a brief introduction, (2) the physical and biological properties of the most common polarized agents with a brief summary of applications and methods of polarization, (3) methods for image acquisition and reconstruction specific to improving data acquisition efficiency for HP MRI, (4) the main physical properties that enable unique measures of physiology or metabolic pathways, followed by a more detailed review of the literature describing the use of HP agents to study: (5) metabolic pathways in cancer and cardiac disease and (6) lung function in both pre-clinical and clinical research studies, concluding with (7) some future directions and challenges, and (8) an overall summary.
Collapse
Affiliation(s)
- Erin B Adamson
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, United States of America
| | | | | | | |
Collapse
|
13
|
Siddiqui S, Kadlecek S, Pourfathi M, Xin Y, Mannherz W, Hamedani H, Drachman N, Ruppert K, Clapp J, Rizi R. The use of hyperpolarized carbon-13 magnetic resonance for molecular imaging. Adv Drug Deliv Rev 2017; 113:3-23. [PMID: 27599979 PMCID: PMC5783573 DOI: 10.1016/j.addr.2016.08.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 08/25/2016] [Accepted: 08/27/2016] [Indexed: 02/06/2023]
Abstract
Until recently, molecular imaging using magnetic resonance (MR) has been limited by the modality's low sensitivity, especially with non-proton nuclei. The advent of hyperpolarized (HP) MR overcomes this limitation by substantially enhancing the signal of certain biologically important probes through a process known as external nuclear polarization, enabling real-time assessment of tissue function and metabolism. The metabolic information obtained by HP MR imaging holds significant promise in the clinic, where it could play a critical role in disease diagnosis and therapeutic monitoring. This review will provide a comprehensive overview of the developments made in the field of hyperpolarized MR, including advancements in polarization techniques and delivery, probe development, pulse sequence optimization, characterization of healthy and diseased tissues, and the steps made towards clinical translation.
Collapse
Affiliation(s)
- Sarmad Siddiqui
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Stephen Kadlecek
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Mehrdad Pourfathi
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Electrical and Systems Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Yi Xin
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - William Mannherz
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Hooman Hamedani
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Nicholas Drachman
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Kai Ruppert
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Justin Clapp
- Department of Anesthesiology and Critical Care, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Rahim Rizi
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
14
|
Drachman N, Kadlecek S, Duncan I, Rizi R. Quantifying reaction kinetics of the non-enzymatic decarboxylation of pyruvate and production of peroxymonocarbonate with hyperpolarized13C-NMR. Phys Chem Chem Phys 2017; 19:19316-19325. [DOI: 10.1039/c7cp02041d] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Hyperpolarized13C-NMR is used to study the reaction mechanism and kinetics for non-enzymatic decarboxylation of pyruvate and formation of peroxymonocarbonate.
Collapse
Affiliation(s)
| | | | - Ian Duncan
- University of Pennsylvania
- Radiology
- Philadelphia
- USA
| | - Rahim Rizi
- University of Pennsylvania
- Radiology
- Philadelphia
- USA
| |
Collapse
|
15
|
Drachman N, Kadlecek S, Pourfathi M, Xin Y, Profka H, Rizi R. In vivo pH mapping of injured lungs using hyperpolarized [1- 13 C]pyruvate. Magn Reson Med 2016; 78:1121-1130. [PMID: 27714832 DOI: 10.1002/mrm.26473] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Revised: 08/26/2016] [Accepted: 08/29/2016] [Indexed: 12/21/2022]
Abstract
PURPOSE To optimize the production of hyperpolarized 13 C-bicarbonate from the decarboxylation of hyperpolarized [1-13 C]pyruvate and use it to image pH in the lungs and heart of rats with acute lung injury. METHODS Two forms of catalysis are compared calorimetrically to maximize the rate of decarboxylation and rapidly produce hyperpolarized bicarbonate from pyruvate while minimizing signal loss. Rats are injured using an acute lung injury model combining ventilator-induced lung injury and acid aspiration. Carbon images are obtained from both healthy (n = 4) and injured (n = 4) rats using a slice-selective chemical shift imaging sequence with low flip angle. pH is calculated from the relative HCO3- and CO2 signals using the Henderson-Hasselbalch equation. RESULTS It is demonstrated that base catalysis is more effective than metal-ion catalysis for this decarboxylation reaction. Bicarbonate polarizations up to 17.2% are achieved using the base-catalyzed reaction. A mean pH difference between lung and heart of 0.14 pH units is measured in the acute lung injury model. A significant pH difference between injured and uninjured lungs is also observed. CONCLUSION It is demonstrated that hyperpolarized 13 C-bicarbonate can be efficiently produced from the base-catalyzed decarboxylation of pyruvate. This method is used to obtain the first regional pH image of the lungs and heart of an animal. Magn Reson Med 78:1121-1130, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Nicholas Drachman
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Stephen Kadlecek
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Mehrdad Pourfathi
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.,Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Yi Xin
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Harilla Profka
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Rahim Rizi
- Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
16
|
Flavell RR, von Morze C, Blecha JE, Korenchan DE, Van Criekinge M, Sriram R, Gordon JW, Chen HY, Subramaniam S, Bok RA, Wang ZJ, Vigneron DB, Larson PE, Kurhanewicz J, Wilson DM. Application of Good's buffers to pH imaging using hyperpolarized (13)C MRI. Chem Commun (Camb) 2016; 51:14119-22. [PMID: 26257040 DOI: 10.1039/c5cc05348j] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
N-(2-Acetamido)-2-aminoethanesulfonic acid (ACES), one of Good's buffers, was applied to pH imaging using hyperpolarized (13)C magnetic resonance spectroscopy. Rapid NMR- and MRI-based pH measurements were obtained by exploiting the sensitive pH-dependence of its (13)C chemical shift within the physiologic range.
Collapse
Affiliation(s)
- Robert R Flavell
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California 94158, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Korenchan DE, Flavell RR, Baligand C, Sriram R, Neumann K, Sukumar S, VanBrocklin H, Vigneron DB, Wilson DM, Kurhanewicz J. Dynamic nuclear polarization of biocompatible (13)C-enriched carbonates for in vivo pH imaging. Chem Commun (Camb) 2016; 52:3030-3. [PMID: 26792559 PMCID: PMC4864526 DOI: 10.1039/c5cc09724j] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
A hyperpolarization technique using carbonate precursors of biocompatible molecules was found to yield high concentrations of hyperpolarized (13)C bicarbonate in solution. This approach enabled large signal gains for low-toxicity hyperpolarized (13)C pH imaging in a phantom and in vivo in a murine model of prostate cancer.
Collapse
Affiliation(s)
- D E Korenchan
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA. and Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - R R Flavell
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - C Baligand
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - R Sriram
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - K Neumann
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - S Sukumar
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - H VanBrocklin
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - D B Vigneron
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA. and Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - D M Wilson
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| | - J Kurhanewicz
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, Berkeley and University of California, San Francisco, California, USA. and Department of Radiology and Biomedical Imaging, University of California, San Francisco, California, USA.
| |
Collapse
|
18
|
Jensen PR, Meier S. Hyperpolarised organic phosphates as NMR reporters of compartmental pH. Chem Commun (Camb) 2016; 52:2288-91. [DOI: 10.1039/c5cc09790h] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
When formed in defined cellular compartments from exogenous hyperpolarised13C substrates, metabolites yield correlations of compartmental pH and catalytic activity.
Collapse
Affiliation(s)
- Pernille Rose Jensen
- Technical University of Denmark
- Department of Electrical Engineering
- DK-2800 Kgs. Lyngby
- Denmark
- Albeda Research
| | - Sebastian Meier
- Technical University of Denmark
- Department of Chemistry
- DK-2800 Kgs. Lyngby
- Denmark
| |
Collapse
|