• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4643723)   Today's Articles (462)   Subscriber (50637)
For: Marcon M, Keller D, Wurnig MC, Weiger M, Kenkel D, Eberhardt C, Eberli D, Boss A. Separation of collagen-bound and porous bone-water longitudinal relaxation in mice using a segmented inversion recovery zero-echo-time sequence. Magn Reson Med 2016;77:1909-1915. [PMID: 27221236 DOI: 10.1002/mrm.26277] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2016] [Revised: 04/18/2016] [Accepted: 04/23/2016] [Indexed: 12/22/2022]
Number Cited by Other Article(s)
1
Boss A, Heeb L, Vats D, Starsich FHL, Balfourier A, Herrmann IK, Gupta A. Assessment of iron nanoparticle distribution in mouse models using ultrashort-echo-time MRI. NMR IN BIOMEDICINE 2022;35:e4690. [PMID: 34994020 PMCID: PMC9286043 DOI: 10.1002/nbm.4690] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 12/29/2021] [Accepted: 12/30/2021] [Indexed: 06/14/2023]
2
Surowiec RK, Allen MR, Wallace JM. Bone hydration: How we can evaluate it, what can it tell us, and is it an effective therapeutic target? Bone Rep 2022;16:101161. [PMID: 35005101 PMCID: PMC8718737 DOI: 10.1016/j.bonr.2021.101161] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/10/2021] [Accepted: 12/11/2021] [Indexed: 12/22/2022]  Open
3
Guo T, Ma Y, Jerban S, Jang H, Zhao W, Chang EY, Chen M, Bydder GM, Du J. T1 measurement of bound water in cortical bone using 3D adiabatic inversion recovery ultrashort echo time (3D IR-UTE) Cones imaging. Magn Reson Med 2019;84:634-645. [PMID: 31863519 DOI: 10.1002/mrm.28140] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2019] [Revised: 11/04/2019] [Accepted: 11/30/2019] [Indexed: 11/11/2022]
4
Weiger M, Pruessmann KP. Short-T2 MRI: Principles and recent advances. PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 2019;114-115:237-270. [PMID: 31779882 DOI: 10.1016/j.pnmrs.2019.07.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 07/14/2019] [Accepted: 07/26/2019] [Indexed: 06/10/2023]
5
Bouazizi K, Guillot G. Cross-relaxation parameters in cortical bone assessed with different MR sequences. NMR IN BIOMEDICINE 2019;32:e4098. [PMID: 30986332 DOI: 10.1002/nbm.4098] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 02/21/2019] [Accepted: 03/05/2019] [Indexed: 06/09/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA