1
|
Nabbout M, Langham MC, Cottrell C, Wehrli FW. Quantification of neurovascular compliance with retrospectively gated phase-contrast MRI. MAGMA (NEW YORK, N.Y.) 2024; 37:307-314. [PMID: 38194215 DOI: 10.1007/s10334-023-01137-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 01/10/2024]
Abstract
OBJECTIVE Neurovascular compliance (NVC) is the change in the brain's arterial tree blood volume, ΔV, divided by the change in intra-vascular blood pressure, ΔP, during the cardiac cycle. The primary aim of this work was to evaluate the performance of MRI measurement of NVC obtained from time-resolved measurements of internal carotid artery (ICA) and vertebral artery (VA) flow rates. A secondary aim was to explore whether NVC could be estimated from common carotid (CCA) flow in conjunction with prior knowledge of mean ICA and VA fractional flow rates, given the small cross-section of ICA and VA in some populations, in particular small children. METHODS ΔV was quantified from the blood flow rate measured at the ICA and VA for actual NVC derivation. It was further estimated from individually measured CCA flow rate and mean flow fractions ICA/CCA and VA/CCA (which could alternatively be obtained from literature data), to yield estimated NVC. Time-resolved blood flow rate in CCA, ICA and VA was obtained via retrospectively-gated 2D PC-MRI at 1.5 T in healthy subjects (N = 16, 8 women, mean age 36 ± 13 years). ΔP was determined via a brachial pressure measurement. RESULTS Actual and estimated mean NVC were 27 ± 15 and 38 ± 15 μL/mmHg, respectively, and the two measurements were strongly correlated (r = 0.80; p = 0.0002) with test-retest intra-class correlation coefficients of 0.964 and 0.899. CONCLUSION Both methods yielded excellent retest precision. In spite of a large bias, actual and estimated NVC were strongly correlated.
Collapse
Affiliation(s)
- Marianne Nabbout
- Laboratory for Structural, Physiologic, and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Michael C Langham
- Laboratory for Structural, Physiologic, and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Christiana Cottrell
- Laboratory for Structural, Physiologic, and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Felix W Wehrli
- Laboratory for Structural, Physiologic, and Functional Imaging, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
2
|
Hays AG, Schär M, Bonanno G, Lai S, Meyer J, Afework Y, Steinberg A, Stradley S, Gerstenblith G, Weiss RG. Randomized Trial of Anti-inflammatory Medications and Coronary Endothelial Dysfunction in Patients With Stable Coronary Disease. Front Cardiovasc Med 2021; 8:728654. [PMID: 34722661 PMCID: PMC8553961 DOI: 10.3389/fcvm.2021.728654] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 09/14/2021] [Indexed: 12/03/2022] Open
Abstract
Aims: Inflammation plays a critical role in the pathogenesis of coronary artery disease (CAD), however the impact of anti-inflammatory therapies to reduce those processes which promote atherosclerosis in CAD patients is unknown. We aimed to test the hypothesis that anti-inflammatory approaches improve impaired coronary endothelial function (CEF), a driver of coronary atherosclerosis, in stable CAD patients. Methods and Results: We performed a single-center, randomized, placebo-controlled, double-blinded trial to assess whether low dose methotrexate (MTX), low dose colchicine (LDC), and/or their combination (MTX+LDC), improves CEF using non-invasive MRI measures in patients with stable CAD (N = 94). The primary endpoint was the MRI-detected change in coronary cross-sectional area from rest to isometric handgrip exercise (IHE), a predominantly nitric oxide-dependent endothelial dependent stressor. Coronary and systemic endothelial endpoints, and serum inflammatory markers, were collected at baseline, 8 and 24 weeks. Anti-inflammatory study drugs were well-tolerated. There were no significant differences in any of the CEF parameters among the four groups (MTX, LDC, MTX+LDC, placebo) at 8 or 24 weeks. Serum markers of inflammation and systemic endothelial function measures were also not significantly different among the groups. Conclusion: This is the first study to examine the effects of the anti-inflammatory approaches using MTX, LDC, and/or the combination in stable CAD patients on CEF, a marker of vascular health and the primary endpoint of the study. Although these anti-inflammatory approaches were relatively well-tolerated, they did not improve coronary endothelial function in patients with stable CAD. Clinical Trial Registration:www.clinicaltrials.gov, identifier: NCT02366091.
Collapse
Affiliation(s)
- Allison G Hays
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Michael Schär
- Division of Magnetic Resonance Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Gabriele Bonanno
- Division of Magnetic Resonance Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Shenghan Lai
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, United States.,Institute of Human Virology, University of Maryland School of Medicine, Baltimore, MD, United States
| | - Joseph Meyer
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Yohannes Afework
- Division of Magnetic Resonance Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Angela Steinberg
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Samuel Stradley
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Gary Gerstenblith
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Robert G Weiss
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States.,Division of Magnetic Resonance Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| |
Collapse
|
3
|
Bonanno G, Weiss RG, Piccini D, Yerly J, Soleimani S, Pan L, Bi X, Hays AG, Stuber M, Schär M. Volumetric coronary endothelial function assessment: a feasibility study exploiting stack-of-stars 3D cine MRI and image-based respiratory self-gating. NMR IN BIOMEDICINE 2021; 34:e4589. [PMID: 34291517 PMCID: PMC8969584 DOI: 10.1002/nbm.4589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 06/25/2021] [Indexed: 06/13/2023]
Abstract
Abnormal coronary endothelial function (CEF), manifesting as depressed vasoreactive responses to endothelial-specific stressors, occurs early in atherosclerosis, independently predicts cardiovascular events, and responds to cardioprotective interventions. CEF is spatially heterogeneous along a coronary artery in patients with atherosclerosis, and thus recently developed and tested non-invasive 2D MRI techniques to measure CEF may not capture the extent of changes in CEF in a given coronary artery. The purpose of this study was to develop and test the first volumetric coronary 3D MRI cine method for assessing CEF along the proximal and mid-coronary arteries with isotropic spatial resolution and in free-breathing. This approach, called 3D-Stars, combines a 6 min continuous, untriggered golden-angle stack-of-stars acquisition with a novel image-based respiratory self-gating method and cardiac and respiratory motion-resolved reconstruction. The proposed respiratory self-gating method agreed well with respiratory bellows and center-of-k-space methods. In healthy subjects, 3D-Stars vessel sharpness was non-significantly different from that by conventional 2D radial in proximal segments, albeit lower in mid-portions. Importantly, 3D-Stars detected normal vasodilatation of the right coronary artery in response to endothelial-dependent isometric handgrip stress in healthy subjects. Coronary artery cross-sectional areas measured using 3D-Stars were similar to those from 2D radial MRI when similar thresholding was used. In conclusion, 3D-Stars offers good image quality and shows feasibility for non-invasively studying vasoreactivity-related lumen area changes along the proximal coronary artery in 3D during free-breathing.
Collapse
Affiliation(s)
- Gabriele Bonanno
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Robert G. Weiss
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Davide Piccini
- Advanced Clinical Imaging Technology, Siemens Healthcare, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, University Hospital of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), University Hospital of Lausanne, Lausanne, Switzerland
| | - Sahar Soleimani
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Li Pan
- Siemens Medical Solutions USA, Inc, Baltimore, MD, USA
| | - Xiaoming Bi
- Siemens Medical Solutions USA, Inc, Los Angeles, CA, USA
| | - Allison G Hays
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Matthias Stuber
- Department of Radiology, University Hospital of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), University Hospital of Lausanne, Lausanne, Switzerland
| | - Michael Schär
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
4
|
A randomized, placebo-controlled, double-blinded clinical trial of colchicine to improve vascular health in people living with HIV. AIDS 2021; 35:1041-1050. [PMID: 33587443 PMCID: PMC8916096 DOI: 10.1097/qad.0000000000002845] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES People living with HIV (PWH) experience an increased burden of coronary artery disease (CAD) believed to be related, in part, to an interplay of chronically increased inflammation and traditional risk factors. Recent trials suggest cardiovascular benefits of the anti-inflammatory, colchicine, in HIV-seronegative CAD patients. However, the impact of colchicine on impaired vascular health, as measured by coronary endothelial function (CEF), an independent contributor to CAD, has not been studied in PWH. We tested the hypothesis that colchicine improves vascular health in PWH. DESIGN This was a randomized, placebo-controlled, double-blinded trial in 81 PWH to test whether low-dose colchicine (0.6 mg daily) improves CEF over 8-24 weeks. METHODS Coronary and systemic endothelial function and serum inflammatory markers were measured at baseline, and at 8 and 24 weeks. The primary endpoint was CEF, measured as the change in coronary blood flow from rest to that during an isometric handgrip exercise, an endothelial-dependent stressor, measured with non-invasive MRI at 8 weeks. RESULTS Colchicine was well tolerated and not associated with increased adverse events. However, there were no significant improvements in coronary or systemic endothelial function or reductions in serum inflammatory markers at 8 or 24 weeks with colchicine as compared to placebo. CONCLUSIONS In PWH with no history of CAD, low-dose colchicine was well tolerated but did not improve impaired coronary endothelial function, a predictor of cardiovascular events. These findings suggest that this anti-inflammatory approach using colchicine in PWH does not improve vascular health, the central, early driver of coronary atherosclerosis.
Collapse
|
5
|
Zhu D, Bonanno G, Hays AG, Weiss RG, Schär M. Phase contrast coronary blood velocity mapping with both high temporal and spatial resolution using triggered Golden Angle rotated Spiral k-t Sparse Parallel imaging (GASSP) with shifted binning. Magn Reson Med 2021; 86:1929-1943. [PMID: 33977581 DOI: 10.1002/mrm.28837] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 03/20/2021] [Accepted: 04/21/2021] [Indexed: 12/25/2022]
Abstract
PURPOSE High temporal and spatial resolutions are required for coronary blood flow measures. Current spiral breath-hold phase contrast (PC) MRI at 3T focus on either high spatial or high temporal resolution. We propose a golden angle (GA) rotated Spiral k-t Sparse Parallel imaging (GASSP) sequence for both high spatial (0.8 mm) and high temporal (<21 ms) resolutions. METHODS GASSP PC data are acquired in left anterior descending and right coronary arteries of eight healthy subjects. Binning of GA rotated spiral data into cardiac frames may lead to large k-space gaps. To reduce those gaps, the binning window is shifted and a triggered GA scheme that resets the rotation angle every heartbeat is proposed. The gap reductions are evaluated in simulations and all subjects. Peak systolic velocity (PSV), peak diastolic velocity (PDV), coronary blood flow rate, and vessel area are validated against two reference scans, and repeatability/reproducibility are determined. RESULTS Shifted binning reduced the mean k-space gaps of the triggered GA scheme by 14°-22° in simulations and about 20° in vivo. The k-space gap across three cardiac frames was reduced with the triggered GA scheme compared to the standard GA scheme (35.3°± 3.6° vs. 43°± 13.7°, t-test P = .04). PSV, PDV, flow rate, and area had high intra-scan repeatability (0.92 ≤ intraclass correlation coefficient [ICC] ≤ 0.99), and inter-scan (0.78 ≤ ICC ≤ 0.91) and intra-observer (0.91 ≤ ICC ≤ 0.98) reproducibility. CONCLUSION GASSP enables single breath-hold coronary PC MRI with high temporal and spatial resolutions. Shifted binning and a triggered GA scheme reduce k-space gaps. Quantitative coronary flow metrics are highly reproducible, especially within the same scanning session.
Collapse
Affiliation(s)
- Dan Zhu
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Gabriele Bonanno
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Medicine, Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Allison G Hays
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Medicine, Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Robert G Weiss
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Medicine, Division of Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Michael Schär
- Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
6
|
Yerly J, Becce F, van Heeswijk RB, Verdun FR, Gubian D, Meuli R, Stuber M. In vitro optimization and comparison of CT angiography versus radial cardiovascular magnetic resonance for the quantification of cross-sectional areas and coronary endothelial function. J Cardiovasc Magn Reson 2019; 21:11. [PMID: 30728035 PMCID: PMC6366062 DOI: 10.1186/s12968-019-0521-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Accepted: 01/14/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Our objectives were first to determine the optimal coronary computed tomography angiography (CTA) protocol for the quantification and detection of simulated coronary artery cross-sectional area (CSA) differences in vitro, and secondly to quantitatively compare the performance of the optimized CTA protocol with a previously validated radial coronary cardiovascular magnetic resonance (CMR) technique. METHODS 256-multidetector CTA and radial coronary CMR were used to obtain images of a custom in vitro resolution phantom simulating a range of physiological responses of coronary arteries to stress. CSAs were automatically quantified and compared with known nominal values to determine the accuracy, precision, signal-to-noise ratio (SNR), and circularity of CSA measurements, as well as the limit of detection (LOD) of CSA differences. Various iodine concentrations, radiation dose levels, tube potentials, and iterative image reconstruction algorithms (ASiR-V) were investigated to determine the optimal CTA protocol. The performance of the optimized CTA protocol was then compared with a radial coronary CMR method previously developed for endothelial function assessment under both static and moving conditions. RESULTS The iodine concentration, dose level, tube potential, and reconstruction algorithm all had significant effects (all p < 0.001) on the accuracy, precision, LOD, SNR, and circularity of CSA measurements with CTA. The best precision, LOD, SNR, and circularity with CTA were achieved with 6% iodine, 20 mGy, 100 kVp, and 90% ASiR-V. Compared with the optimized CTA protocol under static conditions, radial coronary CMR was less accurate (- 0.91 ± 0.13 mm2 vs. -0.35 ± 0.04 mm2, p < 0.001), but more precise (0.08 ± 0.02 mm2 vs. 0.21 ± 0.02 mm2, p < 0.001), and enabled the detection of significantly smaller CSA differences (0.16 ± 0.06 mm2 vs. 0.52 ± 0.04 mm2; p < 0.001; corresponding to CSA percentage differences of 2.3 ± 0.8% vs. 7.4 ± 0.6% for a 3-mm baseline diameter). The same results held true under moving conditions as CSA measurements with CMR were less affected by motion. CONCLUSIONS Radial coronary CMR was more precise and outperformed CTA for the specific task of detecting small CSA differences in vitro, and was able to reliably identify CSA changes an order of magnitude smaller than those reported for healthy physiological vasomotor responses of proximal coronary arteries. However, CTA yielded more accurate CSA measurements, which may prove useful in other clinical scenarios, such as coronary artery stenosis assessment.
Collapse
Affiliation(s)
- Jérôme Yerly
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Ruud B. van Heeswijk
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| | - Francis R. Verdun
- Institute of Radiation Physics, Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Danilo Gubian
- Direction des Constructions, Ingénierie, Technique et Sécurité (CIT-S), Lausanne University Hospital (CHUV and UNIL), Lausanne, Switzerland
| | - Reto Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
| | - Matthias Stuber
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV and UNIL), Rue du Bugnon 46, Lausanne, 1011 VD Switzerland
- Center for Biomedical Imaging (CIBM), Lausanne, Switzerland
| |
Collapse
|