1
|
Wang Y, van Gelderen P, de Zwart JA, Özbay PS, Mandelkow H, Picchioni D, Duyn JH. Cerebrovascular activity is a major factor in the cerebrospinal fluid flow dynamics. Neuroimage 2022; 258:119362. [PMID: 35688316 PMCID: PMC9271599 DOI: 10.1016/j.neuroimage.2022.119362] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 06/02/2022] [Accepted: 06/06/2022] [Indexed: 11/17/2022] Open
Abstract
Cerebrospinal fluid (CSF) provides physical protection to the central nervous system as well as an essential homeostatic environment for the normal functioning of neurons. Additionally, it has been proposed that the pulsatile movement of CSF may assist in glymphatic clearance of brain metabolic waste products implicated in neurodegeneration. In awake humans, CSF flow dynamics are thought to be driven primarily by cerebral blood volume fluctuations resulting from a number of mechanisms, including a passive vascular response to blood pressure variations associated with cardiac and respiratory cycles. Recent research has shown that mechanisms that rely on the action of vascular smooth muscle cells ("cerebrovascular activity") such as neuronal activity, changes in intravascular CO2, and autonomic activation from the brainstem, may lead to CSF pulsations as well. Nevertheless, the relative contribution of these mechanisms to CSF flow remains unclear. To investigate this further, we developed an MRI approach capable of disentangling and quantifying CSF flow components of different time scales associated with these mechanisms. This approach was evaluated on human control subjects (n = 12) performing intermittent voluntary deep inspirations, by determining peak flow velocities and displaced volumes between these mechanisms in the fourth ventricle. We found that peak flow velocities were similar between the different mechanisms, while displaced volumes per cycle were about a magnitude larger for deep inspirations. CSF flow velocity peaked at around 10.4 s (range 7.1-14.8 s, n = 12) following deep inspiration, consistent with known cerebrovascular activation delays for this autonomic challenge. These findings point to an important role of cerebrovascular activity in the genesis of CSF pulsations. Other regulatory triggers for cerebral blood flow such as autonomic arousal and orthostatic challenges may create major CSF pulsatile movement as well. Future quantitative comparison of these and possibly additional types of CSF pulsations with the proposed approach may help clarify the conditions that affect CSF flow dynamics.
Collapse
Affiliation(s)
- Yicun Wang
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States.
| | - Peter van Gelderen
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Jacco A de Zwart
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Pinar S Özbay
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Hendrik Mandelkow
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Dante Picchioni
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| | - Jeff H Duyn
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, MD, United States
| |
Collapse
|
2
|
Parker DL, Payne A, Odéen H. A k-space-based method to measure and correct for temporal B 0 field variations in MR temperature imaging. Magn Reson Med 2022; 88:1098-1111. [PMID: 35576148 PMCID: PMC11034809 DOI: 10.1002/mrm.29275] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/29/2022] [Accepted: 04/01/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE Present a method to use change in phase in repeated Cartesian k-space measurements to monitor the change in magnetic field for dynamic MR temperature imaging. METHODS The method is applied to focused ultrasound heating experiments in a gelatin phantom and an ex vivo salt pork sample, without and with simulated respiratory motion. RESULTS In each experiment, phase variations due to B0 field drift and respiration were readily apparent in the measured phase difference. With correction, the SD of the temperature over time was reduced from 0.18°C to 0.14°C (no breathing) and from 0.81°C to 0.22°C (with breathing) for the gelatin phantom, and from 0.68°C to 0.13°C (no breathing) and from 1.06°C to 0.17°C (with breathing) for the pork sample. The accuracy in nonheated regions, assessed as the RMS error deviation from 0°C, improved from 1.70°C to 1.11°C (no breathing) and from 4.73°C to 1.47°C (with breathing) for the gelatin phantom, and from 5.95°C to 0.88°C (no breathing) and from 13.40°C to 1.73°C (with breathing) for the pork sample. The correction did not affect the temperature measurement accuracy in the heated regions. CONCLUSION This work demonstrates that phase changes resulting from variations in B0 due to drift and respiration, commonly seen in MR thermometry applications, can be measured directly from 3D Cartesian acquisition methods. The correction of temporal field variations using the presented technique improved temperature accuracy, reduced variability in nonheated regions, and did not reduce accuracy in heated regions.
Collapse
Affiliation(s)
- Dennis L Parker
- Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States
| | - Allison Payne
- Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States
| | - Henrik Odéen
- Utah Center for Advanced Imaging Research, Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, Utah, United States
| |
Collapse
|
3
|
Kim K, Ahn J, Yoon K, Ko M, Ahn J, Kim H, Park J, Lee C, Chang D, Oh S. In Vivo Magnetic Resonance Thermometry for Brain and Body Temperature Variations in Canines under General Anesthesia. SENSORS 2022; 22:s22114034. [PMID: 35684654 PMCID: PMC9183176 DOI: 10.3390/s22114034] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/22/2022] [Accepted: 05/24/2022] [Indexed: 02/06/2023]
Abstract
The core body temperature tends to decrease under general anesthesia. Consequently, monitoring the core body temperature during procedures involving general anesthesia is essential to ensure patient safety. In veterinary medicine, rectal temperature is used as an indicator of the core body temperature, owing to the accuracy and convenience of this approach. Some previous studies involving craniotomy reported differences between the brain and core temperatures under general anesthesia. However, noninvasive imaging techniques are required to ascertain this because invasive brain temperature measurements can cause unintended temperature changes by inserting the temperature sensors into the brain or by performing the surgical operations. In this study, we employed in vivo magnetic resonance thermometry to observe the brain temperatures of patients under general anesthesia using the proton resonance frequency shift method. The rectal temperature was also recorded using a fiber optic thermometer during the MR thermometry to compare with the brain temperature changes. When the rectal temperature decreased by 1.4 ± 0.5 °C (mean ± standard deviation), the brain temperature (white matter) decreased by 4.8 ± 0.5 °C. Furthermore, a difference in the temperature reduction of the different types of brain tissue was observed; the reduction in the temperature of white matter exceeded that of gray matter mainly due to the distribution of blood vessels in the gray matter. We also analyzed and interpreted the core temperature changes with the body conditioning scores of subjects to see how the body weight affected the temperature changes.
Collapse
Affiliation(s)
- Keonil Kim
- Bio-Chemical Analysis Team, Center for Research Equipment, Korea Basic Science Institute, Cheongju 28119, Korea; (K.K.); (C.L.)
- Department of Bio-Analytical Science, University of Science and Technology, Daejeon 34113, Korea
| | - Jisoo Ahn
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Kwangyong Yoon
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Minjung Ko
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Jiyoung Ahn
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Hyesung Kim
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Jihyeon Park
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
| | - Chulhyun Lee
- Bio-Chemical Analysis Team, Center for Research Equipment, Korea Basic Science Institute, Cheongju 28119, Korea; (K.K.); (C.L.)
- Department of Bio-Analytical Science, University of Science and Technology, Daejeon 34113, Korea
| | - Dongwoo Chang
- Section of Veterinary Medical Imaging, College of Veterinary Medicine, Chungbuk National University, Cheongju 28644, Korea; (J.A.); (K.Y.); (M.K.); (J.A.); (H.K.); (J.P.)
- Correspondence: (D.C.); (S.O.)
| | - Sukhoon Oh
- Bio-Chemical Analysis Team, Center for Research Equipment, Korea Basic Science Institute, Cheongju 28119, Korea; (K.K.); (C.L.)
- Correspondence: (D.C.); (S.O.)
| |
Collapse
|
4
|
Töger J, Andersen M, Haglund O, Kylkilahti TM, Lundgaard I, Markenroth Bloch K. Real‐time imaging of respiratory effects on cerebrospinal fluid flow in small diameter passageways. Magn Reson Med 2022; 88:770-786. [PMID: 35403247 PMCID: PMC9324219 DOI: 10.1002/mrm.29248] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 03/01/2022] [Accepted: 03/08/2022] [Indexed: 12/03/2022]
Abstract
Purpose Respiration‐related CSF flow through the cerebral aqueduct may be useful for elucidating physiology and pathophysiology of the glymphatic system, which has been proposed as a mechanism of brain waste clearance. Therefore, we aimed to (1) develop a real‐time (CSF) flow imaging method with high spatial and sufficient temporal resolution to capture respiratory effects, (2) validate the method in a phantom setup and numerical simulations, and (3) apply the method in vivo and quantify its repeatability and correlation with different respiratory conditions. Methods A golden‐angle radial flow sequence (reconstructed temporal resolution 168 ms, spatial resolution 0.6 mm) was implemented on a 7T MRI scanner and reconstructed using compressed sensing. A phantom setup mimicked simultaneous cardiac and respiratory flow oscillations. The effect of temporal resolution and vessel diameter was investigated numerically. Healthy volunteers (n = 10) were scanned at four different respiratory conditions, including repeat scans. Results Phantom data show that the developed sequence accurately quantifies respiratory oscillations (ratio real‐time/reference QR = 0.96 ± 0.02), but underestimates the rapid cardiac oscillations (ratio QC = 0.46 ± 0.14). Simulations suggest that QC can be improved by increasing temporal resolution. In vivo repeatability was moderate to very strong for cranial and caudal flow (intraclass correlation coefficient range: 0.55–0.99) and weak to strong for net flow (intraclass correlation coefficient range: 0.48–0.90). Net flow was influenced by respiratory condition (p < 0.01). Conclusions The presented real‐time flow MRI method can quantify respiratory‐related variations of CSF flow in the cerebral aqueduct, but it underestimates rapid cardiac oscillations. In vivo, the method showed good repeatability and a relationship between flow and respiration.
Collapse
Affiliation(s)
- Johannes Töger
- Department of Clinical Sciences Lund, Diagnostic Radiology Lund University, Skåne University Hospital Lund Sweden
| | - Mads Andersen
- Philips Healthcare Copenhagen Denmark
- Lund University, Lund University Bioimaging Center Lund Sweden
| | - Olle Haglund
- Department of Medical Radiation Physics Lund University Lund Sweden
| | - Tekla Maria Kylkilahti
- Department of Experimental Medical Science Lund University Lund Sweden
- Wallenberg Centre for Molecular Medicine Lund University Lund Sweden
| | - Iben Lundgaard
- Department of Experimental Medical Science Lund University Lund Sweden
- Wallenberg Centre for Molecular Medicine Lund University Lund Sweden
| | | |
Collapse
|
5
|
Sakakibara Y, Yatsushiro S, Konta N, Horie T, Kuroda K, Matsumae M. Respiratory-driven Cyclic Cerebrospinal Fluid Motion in the Intracranial Cavity on Magnetic Resonance Imaging: Insights into the Pathophysiology of Neurofluid Dysfunction. Neurol Med Chir (Tokyo) 2021; 61:711-720. [PMID: 34526448 PMCID: PMC8666299 DOI: 10.2176/nmc.oa.2021-0160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Neurofluids, a recently developed term that refers to interstitial fluids in the parenchyma and cerebrospinal fluid (CSF) in the ventricle and subarachnoid space, play a role in draining waste products from the brain. Neurofluids have been implicated in pathological conditions such as Alzheimer’s disease and normal pressure hydrocephalus. Given that CSF moves faster in the CSF cavity than in the brain parenchyma, CSF motion can be detected by magnetic resonance imaging. CSF motion is synchronized to the heartbeat and respiratory cycle, but respiratory cycle-induced CSF motion has yet to be investigated in detail. Therefore, we analyzed CSF motion using dynamic improved motion-sensitized driven-equilibrium steady-state free precession-based analysis. We analyzed CSF motion linked to the respiratory cycle in four women and six men volunteers aged 23 to 38 years. We identified differences between free respiration and tasked respiratory cycle-associated CSF motion in the ventricles and subarachnoid space. Our results indicate that semi-quantitative analysis can be performed using the cranial site at which CSF motion is most prominent as a standard. Our findings may serve as a reference for elucidating the pathophysiology of diseases caused by abnormalities in neurofluids.
Collapse
Affiliation(s)
| | | | - Natsuo Konta
- Department of Radiology, Tokai University School of Medicine.,Graduate School of Radiological Technology, Gunma Prefectural College of Health Sciences
| | - Tomohiko Horie
- Department of Radiology, Tokai University School of Medicine
| | - Kagayaki Kuroda
- Department of Human and Information Sciences, School of Information Science and Technology, Tokai University
| | | |
Collapse
|
6
|
Williams G, Thyagaraj S, Fu A, Oshinski J, Giese D, Bunck AC, Fornari E, Santini F, Luciano M, Loth F, Martin BA. In vitro evaluation of cerebrospinal fluid velocity measurement in type I Chiari malformation: repeatability, reproducibility, and agreement using 2D phase contrast and 4D flow MRI. Fluids Barriers CNS 2021; 18:12. [PMID: 33736664 PMCID: PMC7977612 DOI: 10.1186/s12987-021-00246-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Accepted: 03/03/2021] [Indexed: 11/11/2022] Open
Abstract
Background Phase contrast magnetic resonance imaging, PC MRI, is a valuable tool allowing for non-invasive quantification of CSF dynamics, but has lacked adoption in clinical practice for Chiari malformation diagnostics. To improve these diagnostic practices, a better understanding of PC MRI based measurement agreement, repeatability, and reproducibility of CSF dynamics is needed. Methods An anatomically realistic in vitro subject specific model of a Chiari malformation patient was scanned three times at five different scanning centers using 2D PC MRI and 4D Flow techniques to quantify intra-scanner repeatability, inter-scanner reproducibility, and agreement between imaging modalities. Peak systolic CSF velocities were measured at nine axial planes using 2D PC MRI, which were then compared to 4D Flow peak systolic velocity measurements extracted at those exact axial positions along the model. Results Comparison of measurement results showed good overall agreement of CSF velocity detection between 2D PC MRI and 4D Flow (p = 0.86), fair intra-scanner repeatability (confidence intervals ± 1.5 cm/s), and poor inter-scanner reproducibility. On average, 4D Flow measurements had a larger variability than 2D PC MRI measurements (standard deviations 1.83 and 1.04 cm/s, respectively). Conclusion Agreement, repeatability, and reproducibility of 2D PC MRI and 4D Flow detection of peak CSF velocities was quantified using a patient-specific in vitro model of Chiari malformation. In combination, the greatest factor leading to measurement inconsistency was determined to be a lack of reproducibility between different MRI centers. Overall, these findings may help lead to better understanding for application of 2D PC MRI and 4D Flow techniques as diagnostic tools for CSF dynamics quantification in Chiari malformation and related diseases. Supplementary Information The online version contains supplementary material available at 10.1186/s12987-021-00246-3.
Collapse
Affiliation(s)
- Gwendolyn Williams
- Department of Chemical and Biological Engineering, University of Idaho, 875 Perimeter Dr. MC1122, Moscow, ID, 83844, USA
| | - Suraj Thyagaraj
- Department of Mechanical Engineering, Conquer Chiari Research Center, University of Akron, Akron, OH, 44325, USA
| | - Audrey Fu
- Department of Mathematics and Statistical Science, University of Idaho, Moscow, ID, 83844, USA
| | - John Oshinski
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, 30322, USA
| | - Daniel Giese
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
| | - Alexander C Bunck
- Department of Radiology, University Hospital of Cologne, Cologne, Germany
| | - Eleonora Fornari
- CIBM, Department of Radiology, Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne, Lausanne, Switzerland
| | - Francesco Santini
- Division of Radiological Physics, Department of Radiology, University Hospital of Basel, Basel, Switzerland.,Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Mark Luciano
- Department of Neurosurgery, John Hopkins University, Baltimore, MD, USA
| | - Francis Loth
- Department of Mechanical Engineering, Conquer Chiari Research Center, University of Akron, Akron, OH, 44325, USA
| | - Bryn A Martin
- Department of Chemical and Biological Engineering, University of Idaho, 875 Perimeter Dr. MC1122, Moscow, ID, 83844, USA. .,Alcyone Therapeutics Inc, Lowell, MA, USA.
| |
Collapse
|