Nagar D, Vladimirov N, Farrar CT, Perlman O. Dynamic and rapid deep synthesis of chemical exchange saturation transfer and semisolid magnetization transfer MRI signals. Sci Rep 2023; 13:18291. [PMID: 37880343 PMCID: PMC10600114 DOI: 10.1038/s41598-023-45548-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023] Open
Abstract
Model-driven analysis of biophysical phenomena is gaining increased attention and utility for medical imaging applications. In magnetic resonance imaging (MRI), the availability of well-established models for describing the relations between the nuclear magnetization, tissue properties, and the externally applied magnetic fields has enabled the prediction of image contrast and served as a powerful tool for designing the imaging protocols that are now routinely used in the clinic. Recently, various advanced imaging techniques have relied on these models for image reconstruction, quantitative tissue parameter extraction, and automatic optimization of acquisition protocols. In molecular MRI, however, the increased complexity of the imaging scenario, where the signals from various chemical compounds and multiple proton pools must be accounted for, results in exceedingly long model simulation times, severely hindering the progress of this approach and its dissemination for various clinical applications. Here, we show that a deep-learning-based system can capture the nonlinear relations embedded in the molecular MRI Bloch-McConnell model, enabling a rapid and accurate generation of biologically realistic synthetic data. The applicability of this simulated data for in-silico, in-vitro, and in-vivo imaging applications is then demonstrated for chemical exchange saturation transfer (CEST) and semisolid macromolecule magnetization transfer (MT) analysis and quantification. The proposed approach yielded 63-99% acceleration in data synthesis time while retaining excellent agreement with the ground truth (Pearson's r > 0.99, p < 0.0001, normalized root mean square error < 3%).
Collapse
Affiliation(s)
- Dinor Nagar
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Nikita Vladimirov
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Christian T Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Or Perlman
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel.
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
2
|
Wyatt CR, Guimaraes AR. 3D MR fingerprinting using Seiffert spirals. Magn Reson Med 2022; 88:151-163. [PMID: 35324040 DOI: 10.1002/mrm.29197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 01/17/2022] [Accepted: 01/23/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Seiffert spirals were recently explored as an efficient way to traverse 3D k-space compared to traditional 3D techniques. Several studies have shown the ability of 3D MR fingerprinting (MRF) techniques to acquire T1 and T2 relaxation maps in a short period of time. However, these sequences do not sample across a large region of 3D k-space every TR, especially in the way that Seiffert trajectories can. METHODS A 3D MRF sequence was designed using 8 Seiffert spirals rotated in 3D k-space, with flip angle modulation for T1 and T2 sensitivity. The sequence was compared to an MRF sequence using a 2D spiral rotated in 3D k-space using the tiny golden angle acquisition with similar resolution/readout duration. Both sequences were evaluated using simulations, phantom validation, and in vivo imaging. RESULTS In all experiments, the Seiffert spiral MRF sequence performed similar to if not better than the multi-axis 2D spiral MRF sequence. Strong intraclass correlation coefficients (> 0.9) were found between conventional and MRF sequences in phantoms, whereas the in vivo results showed slightly less aliasing artifact with the Seiffert trajectory. CONCLUSION In this study, Seiffert spirals were used within the MRF framework to acquire high-resolution T1 and T2 relaxation time maps in less than 2.5 min. The reduced aliasing artifacts seen with the Seiffert sequence suggests that sampling over 3D k-space evenly each TR can improve quantification or shorten scan times.
Collapse
Affiliation(s)
- Cory R Wyatt
- Department of Diagnostic Radiology, Oregon Health & Sciences University, Portland, Oregon, USA.,Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, Oregon, USA
| | - Alexander R Guimaraes
- Department of Diagnostic Radiology, Oregon Health & Sciences University, Portland, Oregon, USA.,Advanced Imaging Research Center, Oregon Health & Sciences University, Portland, Oregon, USA
| |
Collapse
|
3
|
Coronado R, Cruz G, Castillo-Passi C, Tejos C, Uribe S, Prieto C, Irarrazaval P. A Spatial Off-Resonance Correction in Spirals for Magnetic Resonance Fingerprinting. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3832-3842. [PMID: 34310296 DOI: 10.1109/tmi.2021.3100293] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In MR Fingerprinting (MRF), balanced Steady-State Free Precession (bSSFP) has advantages over unbalanced SSFP because it retains the spin history achieving a higher signal-to-noise ratio (SNR) and scan efficiency. However, bSSFP-MRF is not frequently used because it is sensitive to off-resonance, producing artifacts and blurring, and affecting the parametric map quality. Here we propose a novel Spatial Off-resonance Correction (SOC) approach for reducing these artifacts in bSSFP-MRF with spiral trajectories. SOC-MRF uses each pixel's Point Spread Function to create system matrices that encode both off-resonance and gridding effects. We iteratively compute the inverse of these matrices to reduce the artifacts. We evaluated the proposed method using brain simulations and actual MRF acquisitions of a standardized T1/T2 phantom and five healthy subjects. The results show that the off-resonance distortions in T1/T2 maps were considerably reduced using SOC-MRF. For T2, the Normalized Root Mean Square Error (NRMSE) was reduced from 17.3 to 8.3% (simulations) and from 35.1 to 14.9% (phantom). For T1, the NRMS was reduced from 14.7 to 7.7% (simulations) and from 17.7 to 6.7% (phantom). For in-vivo, the mean and standard deviation in different ROI in white and gray matter were significantly improved. For example, SOC-MRF estimated an average T2 for white matter of 77ms (the ground truth was 74ms) versus 50 ms of MRF. For the same example the standard deviation was reduced from 18 ms to 6ms. The corrections achieved with the proposed SOC-MRF may expand the potential applications of bSSFP-MRF, taking advantage of its better SNR property.
Collapse
|
4
|
Serrao EM, Kessler DA, Carmo B, Beer L, Brindle KM, Buonincontri G, Gallagher FA, Gilbert FJ, Godfrey E, Graves MJ, McLean MA, Sala E, Schulte RF, Kaggie JD. Magnetic resonance fingerprinting of the pancreas at 1.5 T and 3.0 T. Sci Rep 2020; 10:17563. [PMID: 33067515 PMCID: PMC7567885 DOI: 10.1038/s41598-020-74462-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 09/29/2020] [Indexed: 12/18/2022] Open
Abstract
Magnetic resonance imaging of the pancreas is increasingly used as an important diagnostic modality for characterisation of pancreatic lesions. Pancreatic MRI protocols are mostly qualitative due to time constraints and motion sensitivity. MR Fingerprinting is an innovative acquisition technique that provides qualitative data and quantitative parameter maps from a single free-breathing acquisition with the potential to reduce exam times. This work investigates the feasibility of MRF parameter mapping for pancreatic imaging in the presence of free-breathing exam. Sixteen healthy participants were prospectively imaged using MRF framework. Regions-of-interest were drawn in multiple solid organs including the pancreas and T1 and T2 values determined. MRF T1 and T2 mapping was performed successfully in all participants (acquisition time:2.4-3.6 min). Mean pancreatic T1 values were 37-43% lower than those of the muscle, spleen, and kidney at both 1.5 and 3.0 T. For these organs, the mean pancreatic T2 values were nearly 40% at 1.5 T and < 12% at 3.0 T. The feasibility of MRF at 1.5 T and 3 T was demonstrated in the pancreas. By enabling fast and free-breathing quantitation, MRF has the potential to add value during the clinical characterisation and grading of pathological conditions, such as pancreatitis or cancer.
Collapse
Affiliation(s)
- Eva M Serrao
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Dimitri A Kessler
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Bruno Carmo
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Lucian Beer
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | | | | | - Ferdia A Gallagher
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Fiona J Gilbert
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Edmund Godfrey
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
| | - Martin J Graves
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Mary A McLean
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | - Evis Sala
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
- Cancer Research UK, Cambridge, UK
| | | | - Joshua D Kaggie
- Department of Radiology, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK.
- Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
| |
Collapse
|