Li Z, Zhang H, Wang X, Yang Y, Zhang Y, Zhuang Y, Wei Z, Yang Q, Gao E, Zhang Y, Cai S, Chen Z, Cai C, Bao J, Cheng J. Preoperative Subtyping of WHO Grade 1 Meningiomas Using a Single-Shot Ultrafast MR T2 Mapping. J Magn Reson Imaging 2024; 60:964-976. [PMID: 38112331 DOI: 10.1002/jmri.29183] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Revised: 11/27/2023] [Accepted: 11/30/2023] [Indexed: 12/21/2023] Open
Abstract
BACKGROUND Meningioma subtype is crucial in treatment planning and prognosis delineation, for grade 1 meningiomas. T2 relaxometry could provide detailed microscopic information but is often limited by long scanning times. PURPOSE To investigate the potential of T2 maps derived from multiple overlapping-echo detachment imaging (MOLED) for predicting meningioma subtypes and Ki-67 index, and to compare the diagnostic efficiency of two different region-of-interest (ROI) placements (whole-tumor and contrast-enhanced, respectively). STUDY TYPE Prospective. PHANTOM/SUBJECTS A phantom containing 11 tubes of MnCl2 at different concentrations, eight healthy volunteers, and 75 patients with grade 1 meningioma. FIELD STRENGTH/SEQUENCE 3 T scanner. MOLED, T2-weighted spin-echo sequence, T2-dark-fluid sequence, and postcontrast T1-weighted gradient echo sequence. ASSESSMENT Two ROIs were delineated: the whole-tumor area (ROI1) and contrast-enhanced area (ROI2). Histogram parameters were extracted from T2 maps. Meningioma subtypes and Ki-67 index were reviewed by a neuropathologist according to the 2021 classification criteria. STATISTICAL TESTS Linear regression, Bland-Altman analysis, Pearson's correlation analysis, independent t test, Mann-Whitney U test, Kruskal-Wallis test with Bonferroni correction, and multivariate logistic regression analysis with the P-value significance level of 0.05. RESULTS The MOLED T2 sequence demonstrated excellent accuracy for phantoms and volunteers (Meandiff = -1.29%, SDdiff = 1.25% and Meandiff = 0.36%, SDdiff = 2.70%, respectively), and good repeatability for volunteers (average coefficient of variance = 1.13%; intraclass correlation coefficient = 0.877). For both ROI1 and ROI2, T2 variance had the highest area under the curves (area under the ROC curve = 0.768 and 0.761, respectively) for meningioma subtyping. There was no significant difference between the two ROIs (P = 0.875). Significant correlations were observed between T2 parameters and Ki-67 index (r = 0.237-0.374). DATA CONCLUSION MOLED T2 maps can effectively differentiate between meningothelial, fibrous, and transitional meningiomas. Moreover, T2 histogram parameters were significantly correlated with the Ki-67 index. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Zongye Li
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Hongyan Zhang
- Department of Pathology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xiao Wang
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yijie Yang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Research, Xiamen University, Xiamen, China
| | - Yue Zhang
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yuchuan Zhuang
- Department of Imaging Sciences, University of Rochester Medical Center, Rochester, New York, USA
| | - Zhiliang Wei
- The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Qinqin Yang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Research, Xiamen University, Xiamen, China
| | - Eryuan Gao
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Yong Zhang
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Shuhui Cai
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Research, Xiamen University, Xiamen, China
| | - Zhong Chen
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Research, Xiamen University, Xiamen, China
| | - Congbo Cai
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance Research, Xiamen University, Xiamen, China
| | - Jianfeng Bao
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Jingliang Cheng
- Department of Magnetic Resonance Imaging, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| |
Collapse
|
2
|
Sajib SZK, Chauhan M, Sahu S, Boakye E, Sadleir RJ. Validation of conductivity tensor imaging against diffusion tensor magnetic resonance electrical impedance tomography. Sci Rep 2024; 14:17995. [PMID: 39097661 PMCID: PMC11297941 DOI: 10.1038/s41598-024-68551-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 07/24/2024] [Indexed: 08/05/2024] Open
Abstract
Diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) and electrodeless conductivity tensor imaging (CTI) are two emerging modalities that can quantify low-frequency tissue anisotropic conductivity properties by assuming similar properties underlie ionic mobility and water diffusion. While both methods have potential applications to estimating neuro-modulation fields or formulating forward models used for electrical source imaging, a direct comparison of the two modalities has not yet been performed in-vitro or in-vivo. Therefore, the aim of this study was to test the equivalence of these two modalities. We scanned a tissue phantom and the head of human subject using DT-MREIT and CTI protocols and reconstructed conductivity tensor and effective low frequency conductivities. We found both gray and white matter conductivities recovered by each technique were equivalent within 0.05 S/m. Both DT-MREIT and CTI require multiple processing steps, and we further assess the effects of each factor on reconstructions and evaluate the extent to which different measurement mechanisms potentially cause discrepancies between the two methods. Finally, we discuss the implications for spectral models of measuring conductivity using these techniques. The study further establishes the credibility of CTI as an electrodeless non-invasive method of measuring low frequency conductivity properties.
Collapse
Affiliation(s)
- S Z K Sajib
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, 85287, USA
| | - M Chauhan
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, 85287, USA
- Hoglund Biomedical Imaging Center, University of Kansas Medical Center, Kansas City, KS, 66160, USA
| | - S Sahu
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, 85287, USA
| | - E Boakye
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, 85287, USA
| | - R J Sadleir
- School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, 85287, USA.
| |
Collapse
|
3
|
Fujita S, Gagoski B, Hwang KP, Hagiwara A, Warntjes M, Fukunaga I, Uchida W, Saito Y, Sekine T, Tachibana R, Muroi T, Akatsu T, Kasahara A, Sato R, Ueyama T, Andica C, Kamagata K, Amemiya S, Takao H, Hoshino Y, Tomizawa Y, Yokoyama K, Bilgic B, Hattori N, Abe O, Aoki S. Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: A multicenter and multivendor study. Magn Reson Med 2024; 91:1863-1875. [PMID: 38192263 DOI: 10.1002/mrm.29939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 11/06/2023] [Accepted: 11/06/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping. METHODS This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age ± SD, 28.0 ± 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age ± SD, 48.2 ± 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers. RESULTS Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis. CONCLUSION The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.
Collapse
Affiliation(s)
- Shohei Fujita
- Department of Radiology, Juntendo University, Tokyo, Japan
- Department of Radiology, The University of Tokyo, Tokyo, Japan
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Borjan Gagoski
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Fetal Neonatal Neuroimaging and Developmental Science Center, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Ken-Pin Hwang
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, Texas, USA
| | | | - Marcel Warntjes
- SyntheticMR, Linköping, Sweden
- Center for Medical Imaging Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Issei Fukunaga
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Wataru Uchida
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Yuya Saito
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Towa Sekine
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Rina Tachibana
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Tomoya Muroi
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Toshiya Akatsu
- Department of Radiology, Juntendo University, Tokyo, Japan
| | | | - Ryo Sato
- Department of Radiology, The University of Tokyo, Tokyo, Japan
| | - Tsuyoshi Ueyama
- Department of Radiology, The University of Tokyo, Tokyo, Japan
| | - Christina Andica
- Department of Radiology, Juntendo University, Tokyo, Japan
- Faculty of Health Data Science, Juntendo University, Chiba, Japan
| | - Koji Kamagata
- Department of Radiology, Juntendo University, Tokyo, Japan
| | - Shiori Amemiya
- Department of Radiology, The University of Tokyo, Tokyo, Japan
| | - Hidemasa Takao
- Department of Radiology, The University of Tokyo, Tokyo, Japan
| | | | - Yuji Tomizawa
- Department of Neurology, Juntendo University, Tokyo, Japan
| | | | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard/MIT Health Sciences and Technology, Cambridge, Massachusetts, USA
| | | | - Osamu Abe
- Department of Radiology, The University of Tokyo, Tokyo, Japan
| | - Shigeki Aoki
- Department of Radiology, Juntendo University, Tokyo, Japan
| |
Collapse
|
4
|
LoCastro E, Paudyal R, Konar AS, LaViolette PS, Akin O, Hatzoglou V, Goh AC, Bochner BH, Rosenberg J, Wong RJ, Lee NY, Schwartz LH, Shukla-Dave A. A Quantitative Multiparametric MRI Analysis Platform for Estimation of Robust Imaging Biomarkers in Clinical Oncology. Tomography 2023; 9:2052-2066. [PMID: 37987347 PMCID: PMC10661267 DOI: 10.3390/tomography9060161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/12/2023] [Accepted: 10/18/2023] [Indexed: 11/22/2023] Open
Abstract
There is a need to develop user-friendly imaging tools estimating robust quantitative biomarkers (QIBs) from multiparametric (mp)MRI for clinical applications in oncology. Quantitative metrics derived from (mp)MRI can monitor and predict early responses to treatment, often prior to anatomical changes. We have developed a vendor-agnostic, flexible, and user-friendly MATLAB-based toolkit, MRI-Quantitative Analysis and Multiparametric Evaluation Routines ("MRI-QAMPER", current release v3.0), for the estimation of quantitative metrics from dynamic contrast-enhanced (DCE) and multi-b value diffusion-weighted (DW) MR and MR relaxometry. MRI-QAMPER's functionality includes generating numerical parametric maps from these methods reflecting tumor permeability, cellularity, and tissue morphology. MRI-QAMPER routines were validated using digital reference objects (DROs) for DCE and DW MRI, serving as initial approval stages in the National Cancer Institute Quantitative Imaging Network (NCI/QIN) software benchmark. MRI-QAMPER has participated in DCE and DW MRI Collaborative Challenge Projects (CCPs), which are key technical stages in the NCI/QIN benchmark. In a DCE CCP, QAMPER presented the best repeatability coefficient (RC = 0.56) across test-retest brain metastasis data, out of ten participating DCE software packages. In a DW CCP, QAMPER ranked among the top five (out of fourteen) tools with the highest area under the curve (AUC) for prostate cancer detection. This platform can seamlessly process mpMRI data from brain, head and neck, thyroid, prostate, pancreas, and bladder cancer. MRI-QAMPER prospectively analyzes dose de-escalation trial data for oropharyngeal cancer, which has earned it advanced NCI/QIN approval for expanded usage and applications in wider clinical trials.
Collapse
Affiliation(s)
- Eve LoCastro
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (E.L.); (R.P.); (A.S.K.)
| | - Ramesh Paudyal
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (E.L.); (R.P.); (A.S.K.)
| | - Amaresha Shridhar Konar
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (E.L.); (R.P.); (A.S.K.)
| | - Peter S. LaViolette
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, USA;
| | - Oguz Akin
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (O.A.); (V.H.); (L.H.S.)
| | - Vaios Hatzoglou
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (O.A.); (V.H.); (L.H.S.)
| | - Alvin C. Goh
- Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (A.C.G.); (B.H.B.); (R.J.W.)
| | - Bernard H. Bochner
- Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (A.C.G.); (B.H.B.); (R.J.W.)
| | - Jonathan Rosenberg
- Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA;
| | - Richard J. Wong
- Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (A.C.G.); (B.H.B.); (R.J.W.)
| | - Nancy Y. Lee
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA;
| | - Lawrence H. Schwartz
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (O.A.); (V.H.); (L.H.S.)
| | - Amita Shukla-Dave
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (E.L.); (R.P.); (A.S.K.)
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY 10065, USA; (O.A.); (V.H.); (L.H.S.)
| |
Collapse
|
5
|
Ben-Atya H, Freiman M. P 2T 2: A physically-primed deep-neural-network approach for robust T 2 distribution estimation from quantitative T 2-weighted MRI. Comput Med Imaging Graph 2023; 107:102240. [PMID: 37224742 DOI: 10.1016/j.compmedimag.2023.102240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 04/27/2023] [Accepted: 04/27/2023] [Indexed: 05/26/2023]
Abstract
Estimating T2 relaxation time distributions from multi-echo T2-weighted MRI (T2W) data can provide valuable biomarkers for assessing inflammation, demyelination, edema, and cartilage composition in various pathologies, including neurodegenerative disorders, osteoarthritis, and tumors. Deep neural network (DNN) based methods have been proposed to address the complex inverse problem of estimating T2 distributions from MRI data, but they are not yet robust enough for clinical data with low Signal-to-Noise ratio (SNR) and are highly sensitive to distribution shifts such as variations in echo-times (TE) used during acquisition. Consequently, their application is hindered in clinical practice and large-scale multi-institutional trials with heterogeneous acquisition protocols. We propose a physically-primed DNN approach, called P2T2, that incorporates the signal decay forward model in addition to the MRI signal into the DNN architecture to improve the accuracy and robustness of T2 distribution estimation. We evaluated our P2T2 model in comparison to both DNN-based methods and classical methods for T2 distribution estimation using 1D and 2D numerical simulations along with clinical data. Our model improved the baseline model's accuracy for low SNR levels (SNR<80) which are common in the clinical setting. Further, our model achieved a ∼35% improvement in robustness against distribution shifts in the acquisition process compared to previously proposed DNN models. Finally, Our P2T2 model produces the most detailed Myelin-Water fraction maps compared to baseline approaches when applied to real human MRI data. Our P2T2 model offers a reliable and precise means of estimating T2 distributions from MRI data and shows promise for use in large-scale multi-institutional trials with heterogeneous acquisition protocols. Our source code is available at: https://github.com/Hben-atya/P2T2-Robust-T2-estimation.git.
Collapse
Affiliation(s)
- Hadas Ben-Atya
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
| | - Moti Freiman
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
6
|
Wang Y, Lou H, Xian M, Cui J, Piao Y, Wang C, Zhang L, Xian J. Investigation of the Value of T 2 Mapping in the Prediction of Eosinophilic Chronic Rhinosinusitis With Nasal Polyps. J Comput Assist Tomogr 2023; 47:329-336. [PMID: 36723408 PMCID: PMC10045955 DOI: 10.1097/rct.0000000000001411] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Patients with eosinophilic chronic rhinosinusitis with nasal polyps (eosCRSwNP) usually have more extensive sinus disease, severe symptoms, and poorer disease control compared with patients with non-eosCRSwNP. Separating these entities will be crucial for patient management. The purpose of this study is to investigate T 1, T 2 , and apparent diffusion coefficient (ADC) values of the nasal polyps in patients with CRSwNP and evaluate the usefulness of these parameters for differentiating these diseases. METHODS Sinonasal magnetic resonance imaging was performed in 36 patients with eosCRSwNP and 20 patients with non-eosCRSwNP (including T 1 mapping, T 2 mapping, and diffusion-weighted imaging) before surgery. The T 1 , T 2 , and ADC values were calculated and correlated with pathologically assessed inflammatory cells of nasal polyps. RESULTS Significant higher T 2 value, higher eosinophil count, and lower lymphocyte count of the nasal polyps were observed in eosCRSwNP than those in non-eosCRSwNP. There was no significant difference in T 1 or ADC values between the 2 groups. T 2 value was correlated with eosinophil count and lymphocyte count in CRSwNP. The area under the curve of T 2 value for predicting eosCRSwNP was 0.78 with 89.9% sensitivity and 60.0% specificity. CONCLUSION T 2 value is a promising imaging biomarker for predicting eosCRSwNP. It can help to distinguish eosCRSwNP from non-eosCRSwNP.
Collapse
Affiliation(s)
| | | | | | - Jing Cui
- From the Departments of Radiology
| | | | | | | | | |
Collapse
|
7
|
Palombo M, Valindria V, Singh S, Chiou E, Giganti F, Pye H, Whitaker HC, Atkinson D, Punwani S, Alexander DC, Panagiotaki E. Joint estimation of relaxation and diffusion tissue parameters for prostate cancer with relaxation-VERDICT MRI. Sci Rep 2023; 13:2999. [PMID: 36810476 PMCID: PMC9943845 DOI: 10.1038/s41598-023-30182-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 02/17/2023] [Indexed: 02/23/2023] Open
Abstract
This work presents a biophysical model of diffusion and relaxation MRI for prostate called relaxation vascular, extracellular and restricted diffusion for cytometry in tumours (rVERDICT). The model includes compartment-specific relaxation effects providing T1/T2 estimates and microstructural parameters unbiased by relaxation properties of the tissue. 44 men with suspected prostate cancer (PCa) underwent multiparametric MRI (mp-MRI) and VERDICT-MRI followed by targeted biopsy. We estimate joint diffusion and relaxation prostate tissue parameters with rVERDICT using deep neural networks for fast fitting. We tested the feasibility of rVERDICT estimates for Gleason grade discrimination and compared with classic VERDICT and the apparent diffusion coefficient (ADC) from mp-MRI. The rVERDICT intracellular volume fraction fic discriminated between Gleason 3 + 3 and 3 + 4 (p = 0.003) and Gleason 3 + 4 and ≥ 4 + 3 (p = 0.040), outperforming classic VERDICT and the ADC from mp-MRI. To evaluate the relaxation estimates we compare against independent multi-TE acquisitions, showing that the rVERDICT T2 values are not significantly different from those estimated with the independent multi-TE acquisition (p > 0.05). Also, rVERDICT parameters exhibited high repeatability when rescanning five patients (R2 = 0.79-0.98; CV = 1-7%; ICC = 92-98%). The rVERDICT model allows for accurate, fast and repeatable estimation of diffusion and relaxation properties of PCa sensitive enough to discriminate Gleason grades 3 + 3, 3 + 4 and ≥ 4 + 3.
Collapse
Affiliation(s)
- Marco Palombo
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK.
- Cardiff University Brain Research Imaging Centre, School of Psychology, Cardiff University, Maindy Road, Cardiff, CF24 4HQ, UK.
- School of Computer Science and Informatics, Cardiff University, Cardiff, UK.
| | - Vanya Valindria
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Saurabh Singh
- Centre for Medical Imaging, University College London, London, UK
| | - Eleni Chiou
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Francesco Giganti
- Division of Surgery and Interventional Science, University College London, London, UK
- Department of Radiology, University College London Hospital NHS Foundation Trust, London, UK
| | - Hayley Pye
- Molecular Diagnostics and Therapeutics Group, Division of Surgery & Interventional Science, University College London, London, UK
| | - Hayley C Whitaker
- Molecular Diagnostics and Therapeutics Group, Division of Surgery & Interventional Science, University College London, London, UK
| | - David Atkinson
- Centre for Medical Imaging, University College London, London, UK
| | - Shonit Punwani
- Centre for Medical Imaging, University College London, London, UK
| | - Daniel C Alexander
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| | - Eleftheria Panagiotaki
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK
| |
Collapse
|
8
|
Zhu L, Lu W, Wang F, Wang Y, Wu PY, Zhou J, Liu H. Study of T2 mapping in quantifying and discriminating uterine lesions under different magnetic field strengths: 1.5 T vs. 3.0 T. BMC Med Imaging 2023; 23:1. [PMID: 36600192 PMCID: PMC9811773 DOI: 10.1186/s12880-022-00960-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 12/30/2022] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND MRI is the best imaging tool for the evaluation of uterine tumors, but conventional MRI diagnosis results rely on radiologists and contrast agents (if needed). As a new objective, reproducible and contrast-agent free quantification technique, T2 mapping has been applied to a number of diseases, but studies on the evaluation of uterine lesions and the influence of magnetic field strength are few. Therefore, the aim of this study was to systematically investigate and compare the performance of T2 mapping as a nonenhanced imaging tool in discriminating common uterine lesions between 1.5 T and 3.0 T MRI systems. METHODS A total of 50 healthy subjects and 126 patients with suspected uterine lesions were enrolled in our study, and routine uterine MRI sequences with additional T2 mapping sequences were performed. T2 maps were calculated by monoexponential fitting using a custom code in MATLAB. T2 values of normal uterine structures in the healthy group and lesions (benign: adenomyosis, myoma, endometrial polyps; malignant: cervical cancer, endometrial carcinoma) in the patient group were collected. The differences in T2 values between 1.5 T MRI and 3.0 T MRI in any normal structure or lesion were compared. The comparison of T2 values between benign and malignant lesions was also performed under each magnetic field strength, and the diagnostic efficacies of the T2 value obtained through receiver operating characteristic (ROC) analysis were compared between 1.5 T and 3.0 T. RESULTS The mean T2 value of any normal uterine structure or uterine lesion under 3.0 T MRI was significantly lower than that under 1.5 T MRI (p < 0.05). There were significant differences in T2 values between each lesion subgroup under both 1.5 T and 3.0 T MRI. Moreover, the T2 values of benign lesions (71.1 ± 22.0 ms at 1.5 T and 63.4 ± 19.1 ms at 3.0 T) were also significantly lower than those of malignant lesions (101.1 ± 4.5 ms at 1.5 T and 93.5 ± 5.1 ms at 3.0 T) under both field strengths. In the aspect of differentiating benign from malignant lesions, the area under the curve of the T2 value under 3.0 T (0.94) was significantly higher than that under 1.5 T MRI (0.90) (p = 0.02). CONCLUSION T2 mapping can be a potential tool for quantifying common uterine lesions, and it has better performance in distinguishing benign from malignant lesions under 3.0 T MRI.
Collapse
Affiliation(s)
- Liuhong Zhu
- grid.8547.e0000 0001 0125 2443Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Jihun Road No. 668, Huli District, Xiamen, Fujian China ,Xiamen Municipal Clinical Research Center, Xiamen for Medical Imaging, Xiamen, 361015 China
| | - Weihong Lu
- grid.413087.90000 0004 1755 3939Department of Gynaecology Department, Zhongshan Hospital (Xiamen), Fudan University, Xiamen, Fujian China
| | - Funan Wang
- grid.8547.e0000 0001 0125 2443Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Jihun Road No. 668, Huli District, Xiamen, Fujian China
| | - Yanwei Wang
- Department of Radiology, The Second Affiliated Hospital of Xiamen Medical College, Xiamen, Fujian China
| | | | - Jianjun Zhou
- grid.8547.e0000 0001 0125 2443Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Jihun Road No. 668, Huli District, Xiamen, Fujian China ,grid.413087.90000 0004 1755 3939Department of Radiology, Zhongshan Hospital Fudan University, Xuhui District, Fenglin Road No.180, Shanghai, 200032 China
| | - Hao Liu
- grid.413087.90000 0004 1755 3939Department of Radiology, Zhongshan Hospital Fudan University, Xuhui District, Fenglin Road No.180, Shanghai, 200032 China
| |
Collapse
|
9
|
Antoniou A, Georgiou L, Christodoulou T, Panayiotou N, Ioannides C, Zamboglou N, Damianou C. MR relaxation times of agar-based tissue-mimicking phantoms. J Appl Clin Med Phys 2022; 23:e13533. [PMID: 35415875 PMCID: PMC9121050 DOI: 10.1002/acm2.13533] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 12/29/2021] [Indexed: 12/31/2022] Open
Abstract
Agar gels were previously proven capable of accurately replicating the acoustical and thermal properties of real tissue and widely used for the construction of tissue-mimicking phantoms (TMPs) for focused ultrasound (FUS) applications. Given the current popularity of magnetic resonance-guided FUS (MRgFUS), we have investigated the MR relaxation times T1 and T2 of different mixtures of agar-based phantoms. Nine TMPs were constructed containing agar as the gelling agent and various concentrations of silicon dioxide and evaporated milk. An agar-based phantom doped with wood powder was also evaluated. A series of MR images were acquired in a 1.5 T scanner for T1 and T2 mapping. T2 was predominantly affected by varying agar concentrations. A trend toward decreasing T1 with an increasing concentration of evaporated milk was observed. The addition of silicon dioxide decreased both relaxation times of pure agar gels. The proposed phantoms have great potential for use with the continuously emerging MRgFUS technology. The MR relaxation times of several body tissues can be mimicked by adjusting the concentration of ingredients, thus enabling more accurate and realistic MRgFUS studies.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Leonidas Georgiou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | | | - Natalie Panayiotou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Cleanthis Ioannides
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Nikolaos Zamboglou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
10
|
Martí-Bonmatí L, Rodríguez-Ortega A, Ten-Esteve A, Alberich-Bayarri Á, Celda B, Ferrer E. Quantification of H 217O by 1H-MR imaging at 3 T: a feasibility study. Eur Radiol Exp 2021; 5:56. [PMID: 34966953 PMCID: PMC8716803 DOI: 10.1186/s41747-021-00246-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Accepted: 10/04/2021] [Indexed: 11/10/2022] Open
Abstract
Background Indirect 1H-magnetic resonance (MR) imaging of 17O-labelled water allows imaging in vivo dynamic changes in water compartmentalisation. Our aim was to describe the feasibility of indirect 1H-MR methods to evaluate the effect of H217O on the MR relaxation rates by using conventional a 3-T equipment and voxel-wise relaxation rates. Methods MR images were used to calculate the R1, R2, and R2* relaxation rates in phantoms (19 vials with different H217O concentrations, ranging from 0.039 to 5.5%). Afterwards, an experimental animal pilot study (8 rats) was designed to evaluate the in vivo relative R2 brain dynamic changes related to the intravenous administration of 17O-labelled water in rats. Results There were no significant changes on the R1 and R2* values from phantoms. The R2 obtained with the turbo spin-echo T2-weighted sequence with 20-ms echo time interval had the higher statistical difference (0.67 s−1, interquartile range 0.34, p < 0.001) and Spearman correlation (rho 0.79). The R2 increase was adjusted to a linear fit between 0.25 and 5.5%, represented with equation R2 = 0.405 concentration + 0.3215. The highest significant differences were obtained for the higher concentrations (3.1–5.5%). The rat brain MR experiment showed a mean 10% change in the R2 value after the H217O injection with progressive normalisation. Conclusions Indirect 1H-MR imaging method is able to measure H217O concentration by using R2 values and conventional 3-T MR equipment. Normalised R2 relative dynamic changes after the intravenous injection of a H217O saline solution provide a unique opportunity to map water pathophysiology in vivo, opening the analysis of aquaporins status and modifications by disease at clinically available 3-T proton MR scanners.
Collapse
Affiliation(s)
- Luis Martí-Bonmatí
- Biomedical Imaging Research Group (GIBI230) at La Fe Health Research Institute and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), La Fe University and Polytechnic Hospital, Av. Fernando Abril Martorell, 106, Torre E, Planta 0, 46026, Valencia, Spain.
| | - Alejandro Rodríguez-Ortega
- Biomedical Imaging Research Group (GIBI230) at La Fe Health Research Institute and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), La Fe University and Polytechnic Hospital, Av. Fernando Abril Martorell, 106, Torre E, Planta 0, 46026, Valencia, Spain
| | - Amadeo Ten-Esteve
- Biomedical Imaging Research Group (GIBI230) at La Fe Health Research Institute and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), La Fe University and Polytechnic Hospital, Av. Fernando Abril Martorell, 106, Torre E, Planta 0, 46026, Valencia, Spain
| | - Ángel Alberich-Bayarri
- Biomedical Imaging Research Group (GIBI230) at La Fe Health Research Institute and Imaging La Fe node at Distributed Network for Biomedical Imaging (ReDIB) Unique Scientific and Technical Infrastructures (ICTS), La Fe University and Polytechnic Hospital, Av. Fernando Abril Martorell, 106, Torre E, Planta 0, 46026, Valencia, Spain.,Quantitative Imaging Biomarkers in Medicine, QUIBIM SL, Valencia, Spain
| | - Bernardo Celda
- Physical Chemistry Department, University of Valencia, Valencia, Spain
| | - Eduardo Ferrer
- Radiotherapy Department, Hospital Clínico Universitario, Valencia, Spain
| |
Collapse
|
11
|
Yamada H, Tanikawa M, Sakata T, Aihara N, Mase M. Usefulness of T2 Relaxation Time for Quantitative Prediction of Meningioma Consistency. World Neurosurg 2021; 157:e484-e491. [PMID: 34695610 DOI: 10.1016/j.wneu.2021.10.135] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 10/18/2021] [Accepted: 10/18/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND Meningioma consistency is one of the most critical factors affecting the difficulty of surgery. Although many studies have attempted to predict meningioma consistency via magnetic resonance imaging findings, no definitive method has been established, because most have been based on qualitative evaluations. Therefore, the present study examined the potential of the T2 relaxation time (T2 value), a tissue-specific quantitative parameter, for assessment of meningioma consistency. METHODS Eighteen surgically treated meningiomas in 16 patients were included in the present study. Preoperatively, the T2 values of all meningiomas were calculated pixel by pixel, and a T2 value distribution map was generated. A total of 27 tumor specimens (multiple specimens were procured if heterogeneous) were taken from these meningiomas, with each localization identified intraoperatively using image guidance. The consistency of the specimens was measured with a durometer, originally a device for measuring the hardness of material such as elastic rubber, and their water content was subsequently measured using wet and dry measurements. RESULTS A significant correlation was found between the T2 values of the matched locations identified by image guidance intraoperatively and the consistency measured using the durometer (r = -0.722; P < 0.01) and the water content (r = 0.621; P = 0.01). In addition, the water content correlated significantly with the durometer consistency (r = -0.677; P < 0.01). CONCLUSIONS The T2 values could be a reliable quantitative predictor of meningioma consistency, and the T2 value distribution map, which elucidated the internal structure of the tumor in detail, could provide helpful information for surgical resection.
Collapse
Affiliation(s)
- Hiroshi Yamada
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan
| | - Motoki Tanikawa
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan.
| | - Tomohiro Sakata
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan
| | - Noritaka Aihara
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan
| | - Mitsuhito Mase
- Department of Neurosurgery, Nagoya City University Graduate School of Medical Sciences, Nagoya, Aichi, Japan
| |
Collapse
|
12
|
Fatemi Y, Danyali H, Helfroush MS, Amiri H. Fast T 2 mapping using multi-echo spin-echo MRI: A linear order approach. Magn Reson Med 2020; 84:2815-2830. [PMID: 32430979 PMCID: PMC7402028 DOI: 10.1002/mrm.28309] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 04/13/2020] [Accepted: 04/15/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE Multi-echo spin-echo sequence is commonly used for T2 mapping. The estimated values using conventional exponential fit, however, are hampered by stimulated and indirect echoes leading to overestimation of T2 . Here, we present fast analysis of multi-echo spin-echo (FAMESE) as a novel approach to decrease the complexity of the search space, which leads to accelerated measurement of T2 . METHODS We developed FAMESE based on mathematical analysis of the Bloch equations in which the search space dimension decreased to only one. Then, we tested it in both phantom and human brain. Bland-Altman plot was used to assess the agreement between the estimated T2 values from FAMESE and the ones estimated from single-echo spin-echo sequence. The reliability of FAMESE was assessed by intraclass correlation coefficients. In addition, we investigated the noise stability of the method in synthetic and experimental data. RESULTS In both phantom and healthy participants, FAMESE provided accelerated and SNR-resistant T2 maps. The FAMESE had a very good agreement with the single-echo spin echo for the whole range of T2 values. The intraclass correlation coefficient values for FAMESE were excellent (ie, 0.9998 and 0.9860 < intraclass correlation coefficient < 0.9942 for the phantom and humans, respectively). CONCLUSION Our developed method FAMESE could be considered as a candidate for rapid T2 mapping with a clinically feasible scan time.
Collapse
Affiliation(s)
- Yaghoub Fatemi
- Department of Electrical and Electronics EngineeringShiraz University of TechnologyShirazIran
| | - Habibollah Danyali
- Department of Electrical and Electronics EngineeringShiraz University of TechnologyShirazIran
| | | | - Houshang Amiri
- Neuroscience Research CenterInstitute of NeuropharmacologyKerman University of Medical SciencesKermanIran
- Department of Radiology and Nuclear MedicineVU University Medical CenterAmsterdamthe Netherlands
| |
Collapse
|