Wu C, Krishnamoorthy G, Yu V, Subashi E, Rimner A, Otazo R. 4D lung MRI with high-isotropic-resolution using half-spoke (UTE) and full-spoke 3D radial acquisition and temporal compressed sensing reconstruction. Phys Med Biol 2023; 68. [PMID: 36535035 DOI: 10.1088/1361-6560/acace6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 12/19/2022] [Indexed: 12/23/2022]
Abstract
Objective. To develop a respiratory motion-resolved four-dimensional (4D) magnetic resonance imaging (MRI) technique with high-isotropic-resolution (1.1 mm) using 3D radial sampling, camera-based respiratory motion sensing, and temporal compressed sensing reconstruction for lung cancer imaging.Approach. Free-breathing half- and full-spoke 3D golden-angle radial acquisitions were performed on eight healthy volunteers and eight patients with lung tumors of varying size. A back-and-forth k-space ordering between consecutive interleaves of the 3D radial acquisition was performed to minimize eddy current-related artifacts. Data were sorted into respiratory motion states using camera-based motion navigation and 4D images were reconstructed using temporal compressed sensing to reduce scan time. Normalized sharpness indices of the diaphragm, apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio (CNR) of the lung tumor (patients only), liver, and aortic arch were compared between half- and full-spoke 4D MRI images to evaluate the impact of respiratory motion and image contrast on 4D MRI image quality. Respiration-induced changes in lung volumes and center of mass shifts were compared between half- and full-spoke 4D MRI measurements. In addition, the motion measurements from 4D MRI and the same-day 4D CT were presented in one of the lung tumor patients.Main results. Half-spoke 4D MRI provides better visualization of the lung parenchyma, while full-spoke 4D MRI presents sharper diaphragm images and higher aSNR and CNR in the lung tumor, liver, and aortic arch. Lung volume changes and center of mass shifts measured by half- and full-spoke 4D MRI were not statistically different. For the patient with 4D MRI and same-day 4D CT, lung volume changes and center of mass shifts were generally comparable.Significance. This work demonstrates the feasibility of a motion-resolved 4D MRI technique with high-isotropic-resolution using 3D radial acquisition, camera-based respiratory motion sensing, and temporal compressed sensing reconstruction for treatment planning and motion monitoring in radiotherapy of lung cancer.
Collapse
Affiliation(s)
- Can Wu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | | | - Victoria Yu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Ergys Subashi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America.,Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, United States of America
| |
Collapse
|
2
|
Ljungberg E, Wood TC, Solana AB, Williams SCR, Barker GJ, Wiesinger F. Motion corrected silent ZTE neuroimaging. Magn Reson Med 2022; 88:195-210. [PMID: 35381110 PMCID: PMC9321117 DOI: 10.1002/mrm.29201] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Revised: 01/16/2022] [Accepted: 01/28/2022] [Indexed: 11/11/2022]
Abstract
Purpose To develop self‐navigated motion correction for 3D silent zero echo time (ZTE) based neuroimaging and characterize its performance for different types of head motion. Methods The proposed method termed MERLIN (Motion Estimation & Retrospective correction Leveraging Interleaved Navigators) achieves self‐navigation by using interleaved 3D phyllotaxis k‐space sampling. Low resolution navigator images are reconstructed continuously throughout the ZTE acquisition using a sliding window and co‐registered in image space relative to a fixed reference position. Rigid body motion corrections are then applied retrospectively to the k‐space trajectory and raw data and reconstructed into a final, high‐resolution ZTE image. Results MERLIN demonstrated successful and consistent motion correction for magnetization prepared ZTE images for a range of different instructed motion paradigms. The acoustic noise response of the self‐navigated phyllotaxis trajectory was found to be only slightly above ambient noise levels (<4 dBA). Conclusion Silent ZTE imaging combined with MERLIN addresses two major challenges intrinsic to MRI (i.e., subject motion and acoustic noise) in a synergistic and integrated manner without increase in scan time and thereby forms a versatile and powerful framework for clinical and research MR neuroimaging applications.
Collapse
Affiliation(s)
- Emil Ljungberg
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK.,Department of Medical Radiation Physics, Lund University, Lund, Sweden
| | - Tobias C Wood
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | | | - Steven C R Williams
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Gareth J Barker
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK
| | - Florian Wiesinger
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK.,GE Healthcare, Munich, Germany
| |
Collapse
|
3
|
Zhu X, Tan F, Johnson K, Larson P. Optimizing trajectory ordering for fast radial ultra-short TE (UTE) acquisitions. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2021; 327:106977. [PMID: 33873091 PMCID: PMC8164474 DOI: 10.1016/j.jmr.2021.106977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 03/26/2021] [Accepted: 03/30/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE Additional spoiler gradients are required in 3D UTE sequences with random view ordering to suppress magnetization refocusing. By leveraging the encoding gradient induced spoiling effect, the spoiler gradients could potentially be reduced or removed to shorten the TR and increase encoding efficiency. An analysis framework is built that models the gradient spoiling effects and a new ordering scheme is proposed for fast 3D UTE acquisition. THEORY AND METHODS UTE signal evolution and spatial encoding gradient induced spoiling effect are derived from the Bloch equations. And the concept is validated in 2D radial UTE simulation. Then an optimized ordering scheme, named reordered 2D golden angle (r2DGA) scheme, for 3D UTE acquisition is proposed. The r2DGA scheme is compared to the sequential and 3D golden angle schemes in both phantom and volunteer studies. RESULTS The proposed r2DGA ordering scheme was applied to two applications, single breath-holding and free breathing 3D lung MRI. With r2DGA ordering scheme, breath-holding lung MRI scan increased 60% scan efficiency by removing the spoiler gradients and the free breathing scan reduced 20% scan time compared to the 3D golden angle scheme by reducing the spoiler gradients. CONCLUSIONS The proposed r2DGA ordering scheme UTE acquisition reduces the need of spoiler gradients and increases the encoding efficiency, and shows improvements in both breath-holding and free breathing lung MRI applications.
Collapse
Affiliation(s)
- Xucheng Zhu
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States; GE Healthcare, Menlo Park, CA, United States
| | - Fei Tan
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
| | - Kevin Johnson
- Medical Physics, University of Wisconsin, Madison, WI, United States; Radiology, University of Wisconsin, Madison, WI, United States
| | - Peder Larson
- UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco and University of California, Berkeley, CA, United States; Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States.
| |
Collapse
|
4
|
Krishnamoorthy G, Smink J, Tourais J, Breeuwer M, Kouwenhoven M. Variable anisotropic FOV for 3D radial imaging with spiral phyllotaxis (VASP). Magn Reson Med 2020; 85:68-77. [PMID: 32851711 PMCID: PMC7692914 DOI: 10.1002/mrm.28449] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 05/30/2020] [Accepted: 07/08/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To develop a new 3D radial trajectory based on the natural spiral phyllotaxis (SP), with variable anisotropic FOV. THEORY & METHODS A 3D radial trajectory based on the SP with favorable interleaving properties for cardiac imaging has been proposed by Piccini et al (Magn Reson Med. 2011;66:1049-1056), which supports a FOV with a fixed anisotropy. However, a fixed anisotropy can be inefficient when sampling objects with different anisotropic dimensions. We extend Larson's 3D radial method to provide variable anisotropic FOV for spiral phyllotaxis (VASP). Simulations were performed to measure distance between successive projections, analyze point spread functions, and compare aliasing artifacts for both VASP and conventional SP. VASP was fully implemented on a whole-body clinical MR scanner. Phantom and in vivo cardiac images were acquired at 1.5 tesla. RESULTS Simulations, phantom, and in vivo experiments confirmed that VASP can achieve variable anisotropic FOV while maintaining the favorable interleaving properties of SP. For an anisotropic FOV with 100:100:35 ratio, VASP required ~65% fewer radial projections than the conventional SP to satisfy Nyquist criteria. Alternatively, when the same number of radial projections were used as in conventional SP, VASP produced fewer aliasing artifacts for anisotropic objects within the excited imaging volumes. CONCLUSION We have developed a new method (VASP), which enables variable anisotropic FOV for 3D radial trajectory with SP. For anisotropic objects within the excited imaging volumes, VASP can reduce scan times and/or reduce aliasing artifacts.
Collapse
Affiliation(s)
- Guruprasad Krishnamoorthy
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Jouke Smink
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands
| | - Joao Tourais
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel Breeuwer
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marc Kouwenhoven
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands
| |
Collapse
|