Ahanonu E, Goerke U, Johnson K, Toner B, Martin DR, Deshpande V, Bilgin A, Altbach M. Accelerated 2D radial Look-Locker T1 mapping using a deep learning-based rapid inversion recovery sampling technique. NMR IN BIOMEDICINE 2024; 37:e5266. [PMID: 39358992 DOI: 10.1002/nbm.5266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 09/01/2024] [Accepted: 09/17/2024] [Indexed: 10/04/2024]
Abstract
Efficient abdominal coverage with T1-mapping methods currently available in the clinic is limited by the breath hold period (BHP) and the time needed for T1 recovery. This work develops a T1-mapping framework for efficient abdominal coverage based on rapid T1 recovery curve (T1RC) sampling, slice-selective inversion, optimized slice interleaving, and a convolutional neural network (CNN)-based T1 estimation. The effect of reducing the T1RC sampling was evaluated by comparing T1 estimates from T1RC ranging from 0.63 to 2.0 s with reference T1 values obtained from T1RC = 2.5-5 s. Slice interleaving methodologies were evaluated by comparing the T1 variation in abdominal organs across slices. The repeatability of the proposed framework was demonstrated by performing acquisition on test subjects across imaging sessions. Analysis of in vivo data based on retrospectively shortening the T1RC showed that with the CNN framework, a T1RC = 0.84 s yielded T1 estimates without significant changes in mean T1 (p > 0.05) or significant increase in T1 variability (p > 0.48) compared to the reference. Prospectively acquired data using T1RC = 0.84 s, an optimized slice interleaving scheme, and the CNN framework enabled 21 slices in a 20 s BHP. Analyses across abdominal organs produced T1 values within 2% of the reference. Repeatability experiments yielded Pearson's correlation, repeatability coefficient, and coefficient of variation of 0.99, 2.5%, and 0.12%, respectively. The proposed T1 mapping framework provides full abdominal coverage within a single BHP.
Collapse
Affiliation(s)
- Eze Ahanonu
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona, USA
| | - Ute Goerke
- Siemens Medical Solutions USA, Tucson, Arizona, USA
| | - Kevin Johnson
- Department of Medical Imaging, The University of Arizona, Tucson, Arizona, USA
| | - Brian Toner
- Applied Math Program, The University of Arizona, Tucson, Arizona, USA
| | - Diego R Martin
- Department of Radiology, Houston Methodist Hospital, Houston, Texas, USA
| | | | - Ali Bilgin
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona, USA
- Department of Medical Imaging, The University of Arizona, Tucson, Arizona, USA
- Applied Math Program, The University of Arizona, Tucson, Arizona, USA
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona, USA
| | - Maria Altbach
- Department of Medical Imaging, The University of Arizona, Tucson, Arizona, USA
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona, USA
| |
Collapse
|
2
|
Young G, Nguyen VS, Howlett-Prieto Q, Abuaf AF, Carroll TJ, Kawaji K, Javed A. T1 mapping from routine 3D T1-weighted inversion recovery sequences in clinical practice: comparison against reference inversion recovery fast field echo T1 scans and feasibility in multiple sclerosis. Neuroradiology 2024; 66:1709-1719. [PMID: 38880824 DOI: 10.1007/s00234-024-03400-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2024] [Accepted: 06/06/2024] [Indexed: 06/18/2024]
Abstract
BACKGROUND AND PURPOSE Quantitative T1 mapping can be an essential tool for assessing tissue injury in multiple sclerosis (MS). We introduce T1-REQUIRE, a method that converts a single high-resolution anatomical 3D T1-weighted Turbo Field Echo (3DT1TFE) scan into a parametric T1 map that could be used for quantitative assessment of tissue damage. We present the accuracy and feasibility of this method in MS. METHODS 14 subjects with relapsing-remitting MS and 10 healthy subjects were examined. T1 maps were generated from 3DT1TFE images using T1-REQUIRE, which estimates T1 values using MR signal equations and internal tissue reference T1 values. Estimated T1 of lesions, white, and gray matter regions were compared with reference Inversion-Recovery Fast Field Echo T1 values and analyzed via correlation and Bland-Altman (BA) statistics. RESULTS 159 T1-weighted (T1W) hypointense MS lesions and 288 gray matter regions were examined. T1 values for MS lesions showed a Pearson's correlation of r = 0.81 (p < 0.000), R2 = 0.65, and Bias = 4.18%. BA statistics showed a mean difference of -53.95 ms and limits of agreement (LOA) of -344.20 and 236.30 ms. Non-lesional normal-appearing white matter had a correlation coefficient of r = 0.82 (p < 0.000), R2 = 0.67, Bias = 8.78%, mean difference of 73.87 ms, and LOA of -55.67 and 203.41 ms. CONCLUSIONS We demonstrate the feasibility of retroactively derived high-resolution T1 maps from routinely acquired anatomical images, which could be used to quantify tissue pathology in MS. The results of this study will set the stage for testing this method in larger clinical studies for examining MS disease activity and progression.
Collapse
Affiliation(s)
- Griffin Young
- Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Vivian S Nguyen
- Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Quentin Howlett-Prieto
- Department of Neurology and Rehabilitation, University of Illinois at Chicago, Chicago, IL, USA
| | | | - Timothy J Carroll
- Department of Radiology, The University of Chicago, Chicago, IL, USA
| | - Keigo Kawaji
- Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Adil Javed
- Department of Neurology, The University of Chicago, Chicago, IL, 5841 South Maryland Avenue, MC2030, 60637, USA.
| |
Collapse
|
3
|
Huaroc Moquillaza E, Weiss K, Stelter J, Steinhelfer L, Lee YJ, Amthor T, Koken P, Makowski MR, Braren R, Doneva M, Karampinos DC. Accelerated liver water T 1 mapping using single-shot continuous inversion-recovery spiral imaging. NMR IN BIOMEDICINE 2024; 37:e5097. [PMID: 38269568 DOI: 10.1002/nbm.5097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 11/21/2023] [Accepted: 12/06/2023] [Indexed: 01/26/2024]
Abstract
PURPOSE Liver T1 mapping techniques typically require long breath holds or long scan time in free-breathing, need correction for B 1 + inhomogeneities and process composite (water and fat) signals. The purpose of this work is to accelerate the multi-slice acquisition of liver water selective T1 (wT1) mapping in a single breath hold, improving the k-space sampling efficiency. METHODS The proposed continuous inversion-recovery (IR) Look-Locker methodology combines a single-shot gradient echo spiral readout, Dixon processing and a dictionary-based analysis for liver wT1 mapping at 3 T. The sequence parameters were adapted to obtain short scan times. The influence of fat, B 1 + inhomogeneities and TE on the estimation of T1 was first assessed using simulations. The proposed method was then validated in a phantom and in 10 volunteers, comparing it with MRS and the modified Look-Locker inversion-recovery (MOLLI) method. Finally, the clinical feasibility was investigated by comparing wT1 maps with clinical scans in nine patients. RESULTS The phantom results are in good agreement with MRS. The proposed method encodes the IR-curve for the liver wT1 estimation, is minimally sensitive to B 1 + inhomogeneities and acquires one slice in 1.2 s. The volunteer results confirmed the multi-slice capability of the proposed method, acquiring nine slices in a breath hold of 11 s. The present work shows robustness to B 1 + inhomogeneities (wT 1 , No B 1 + = 1.07 wT 1 , B 1 + - 45.63 , R 2 = 0.99 ) , good repeatability (wT 1 , 2 ° = 1 . 0 wT 1 , 1 ° - 2.14 , R 2 = 0.96 ) and is in better agreement with MRS (wT 1 = 0.92 wT 1 MRS + 103.28 , R 2 = 0.38 ) than is MOLLI (wT 1 MOLLI = 0.76 wT 1 MRS + 254.43 , R 2 = 0.44 ) . The wT1 maps in patients captured diverse lesions, thus showing their clinical feasibility. CONCLUSION A single-shot spiral acquisition can be combined with a continuous IR Look-Locker method to perform rapid repeatable multi-slice liver water T1 mapping at a rate of 1.2 s per slice without a B 1 + map. The proposed method is suitable for nine-slice liver clinical applications acquired in a single breath hold of 11 s.
Collapse
Affiliation(s)
- Elizabeth Huaroc Moquillaza
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Jonathan Stelter
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Lisa Steinhelfer
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | | | | | - Marcus R Makowski
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Rickmer Braren
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Dimitrios C Karampinos
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| |
Collapse
|
4
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
5
|
Elsaid NMH, Tagare HD, Galiana G. A Physics-Based Algorithm to Universally Standardize Routinely Obtained Clinical T 2-Weighted Images. Acad Radiol 2024; 31:582-595. [PMID: 37407374 PMCID: PMC10761595 DOI: 10.1016/j.acra.2023.05.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 05/15/2023] [Accepted: 05/29/2023] [Indexed: 07/07/2023]
Abstract
RATIONALE AND OBJECTIVES MR images can be challenging for machine learning and other large-scale analyses because most clinical images, for example, T2-weighted (T2w) images, reflect not only the biologically relevant T2 of tissue but also hardware and acquisition parameters that vary from site to site. Quantitative T2 mapping avoids these confounds because it quantitatively isolates the biological parameter of interest, thus representing a universal standardization across sites. However, efforts to incorporate quantitative mapping sequences into routine clinical practice have seen slow adoption. Here we show, for the first time, that the routine T2w complex raw dataset can be successfully regarded as a quantitative mapping sequence that can be reconstructed with classical optimization methods and physics-based constraints. MATERIALS AND METHODS While previous constrained reconstruction methods are unable to reconstruct a T2 map based on this data, the expanding-constrained alternating minimization for parameter mapping (e-CAMP), which employs stepwise initialization, a linearized version of the exponential model and a phase conjugacy constraint, is demonstrated to provide useful quantitative maps directly from a vendor T2w single image data. RESULTS This paper introduces the method and demonstrates its performance using simulations, retrospectively undersampled brain images, and prospectively acquired T2w images taken on both phantom and brain. CONCLUSION Because T2w scans are included in nearly every protocol, this approach could open the door to creating large, standardized datasets without requiring widespread changes in clinical protocols.
Collapse
Affiliation(s)
- Nahla M H Elsaid
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, 300 Cedar St, New Haven, CT 06519 (N.M.H.E., H.D.T., G.G.).
| | - Hemant D Tagare
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, 300 Cedar St, New Haven, CT 06519 (N.M.H.E., H.D.T., G.G.); Department of Biomedical Engineering, Yale University, New Haven, Connecticut (H.D.T., G.G.)
| | - Gigi Galiana
- Department of Radiology and Biomedical Imaging, Yale School of Medicine, 300 Cedar St, New Haven, CT 06519 (N.M.H.E., H.D.T., G.G.); Department of Biomedical Engineering, Yale University, New Haven, Connecticut (H.D.T., G.G.)
| |
Collapse
|
6
|
Arefeen Y, Xu J, Zhang M, Dong Z, Wang F, White J, Bilgic B, Adalsteinsson E. Latent signal models: Learning compact representations of signal evolution for improved time-resolved, multi-contrast MRI. Magn Reson Med 2023; 90:483-501. [PMID: 37093775 DOI: 10.1002/mrm.29657] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 03/09/2023] [Accepted: 03/16/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE To improve time-resolved reconstructions by training auto-encoders to learn compact representations of Bloch-simulated signal evolution and inserting the decoder into the forward model. METHODS Building on model-based nonlinear and linear subspace techniques, we train auto-encoders on dictionaries of simulated signal evolution to learn compact, nonlinear, latent representations. The proposed latent signal model framework inserts the decoder portion of the auto-encoder into the forward model and directly reconstructs the latent representation. Latent signal models essentially serve as a proxy for fast and feasible differentiation through the Bloch equations used to simulate signal. This work performs experiments in the context of T2 -shuffling, gradient echo EPTI, and MPRAGE-shuffling. We compare how efficiently auto-encoders represent signal evolution in comparison to linear subspaces. Simulation and in vivo experiments then evaluate if reducing degrees of freedom by incorporating our proxy for the Bloch equations, the decoder portion of the auto-encoder, into the forward model improves reconstructions in comparison to subspace constraints. RESULTS An auto-encoder with 1 real latent variable represents single-tissue fast spin echo, EPTI, and MPRAGE signal evolution to within 0.15% normalized RMS error, enabling reconstruction problems with 3 degrees of freedom per voxel (real latent variable + complex scaling) in comparison to linear models with 4-8 degrees of freedom per voxel. In simulated/in vivo T2 -shuffling and in vivo EPTI experiments, the proposed framework achieves consistent quantitative normalized RMS error improvement over linear approaches. From qualitative evaluation, the proposed approach yields images with reduced blurring and noise amplification in MPRAGE-shuffling experiments. CONCLUSION Directly solving for nonlinear latent representations of signal evolution improves time-resolved MRI reconstructions.
Collapse
Affiliation(s)
- Yamin Arefeen
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Junshen Xu
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Molin Zhang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Zijing Dong
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
| | - Fuyixue Wang
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
| | - Jacob White
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Berkin Bilgic
- Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Elfar Adalsteinsson
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Harvard-MIT Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
7
|
Scholand N, Wang X, Roeloffs V, Rosenzweig S, Uecker M. Quantitative MRI by nonlinear inversion of the Bloch equations. Magn Reson Med 2023; 90:520-538. [PMID: 37093980 DOI: 10.1002/mrm.29664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/16/2023] [Accepted: 03/20/2023] [Indexed: 04/26/2023]
Abstract
PURPOSE Development of a generic model-based reconstruction framework for multiparametric quantitative MRI that can be used with data from different pulse sequences. METHODS Generic nonlinear model-based reconstruction for quantitative MRI estimates parametric maps directly from the acquired k-space by numerical optimization. This requires numerically accurate and efficient methods to solve the Bloch equations and their partial derivatives. In this work, we combine direct sensitivity analysis and pre-computed state-transition matrices into a generic framework for calibrationless model-based reconstruction that can be applied to different pulse sequences. As a proof-of-concept, the method is implemented and validated for quantitative T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ mapping with single-shot inversion-recovery (IR) FLASH and IR bSSFP sequences in simulations, phantoms, and the human brain. RESULTS The direct sensitivity analysis enables a highly accurate and numerically stable calculation of the derivatives. The state-transition matrices efficiently exploit repeating patterns in pulse sequences, speeding up the calculation by a factor of 10 for the examples considered in this work, while preserving the accuracy of native ordinary differential equations solvers. The generic model-based method reproduces quantitative results of previous model-based reconstructions based on the known analytical solutions for radial IR FLASH. For IR bSFFP it produces accurate T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ maps for the National Insitute of Standards and Technology (NIST) phantom in numerical simulations and experiments. Feasibility is also shown for human brain, although results are affected by magnetization transfer effects. CONCLUSION By developing efficient tools for numerical optimizations using the Bloch equations as forward model, this work enables generic model-based reconstruction for quantitative MRI.
Collapse
Affiliation(s)
- Nick Scholand
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
| | - Xiaoqing Wang
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
| | - Volkert Roeloffs
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Sebastian Rosenzweig
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Martin Uecker
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Göttingen, Germany
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Cluster of Excellence "Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells" (MBExC), University of Göttingen, Göttingen, Germany
| |
Collapse
|
8
|
Wang X, Rosenzweig S, Roeloffs V, Blumenthal M, Scholand N, Tan Z, Holme HCM, Unterberg-Buchwald C, Hinkel R, Uecker M. Free-breathing myocardial T 1 mapping using inversion-recovery radial FLASH and motion-resolved model-based reconstruction. Magn Reson Med 2023; 89:1368-1384. [PMID: 36404631 PMCID: PMC9892313 DOI: 10.1002/mrm.29521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 09/22/2022] [Accepted: 10/20/2022] [Indexed: 11/22/2022]
Abstract
PURPOSE To develop a free-breathing myocardialT 1 $$ {\mathrm{T}}_1 $$ mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction. METHODS Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incompleteT 1 $$ {\mathrm{T}}_1 $$ recovery into account for an accurateT 1 $$ {\mathrm{T}}_1 $$ calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, 11 human subjects, and a young landrace pig with myocardial infarction. RESULTS In comparison to an IR spin-echo reference, phantom results confirm goodT 1 $$ {\mathrm{T}}_1 $$ accuracy, when reducing the waiting time from 5 s to 1 s using the new correction. The motion-resolved model-based reconstruction further improvesT 1 $$ {\mathrm{T}}_1 $$ precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardialT 1 $$ {\mathrm{T}}_1 $$ maps can be obtained within 2 min with good precision and repeatability. CONCLUSION Motion-resolved myocardialT 1 $$ {\mathrm{T}}_1 $$ mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.
Collapse
Affiliation(s)
- Xiaoqing Wang
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Sebastian Rosenzweig
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Volkert Roeloffs
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
| | - Moritz Blumenthal
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
| | - Nick Scholand
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
| | - Zhengguo Tan
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | | | - Christina Unterberg-Buchwald
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
| | - Rabea Hinkel
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
- Laboratory Animal Science Unit, Leibniz Institute for Primate Research, Deutsches Primatenzentrum GmbH, Göttingen, Germany
- Institute for Animal Hygiene, Animal Welfare and Farm Animal Behavior, University of Veterinary Medicine, Hannover, Germany
| | - Martin Uecker
- Institute of Biomedical Imaging, Graz University of Technology, Graz, Austria
- Institute for Diagnostic and Interventional Radiology of the University Medical Center Göttingen, Germany
- German Centre for Cardiovascular Research (DZHK), Partner Site Göttingen, Germany
- Cluster of “Excellence Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells” (MBExC), University of Göttingen, Germany
- BioTechMed-Graz, Graz, Austria
| |
Collapse
|
9
|
Li Z, Mathew M, Syed AB, Feng L, Brunsing R, Pauly JM, Vasanawala SS. Rapid fat-water separated T 1 mapping using a single-shot radial inversion-recovery spoiled gradient recalled pulse sequence. NMR IN BIOMEDICINE 2022; 35:e4803. [PMID: 35891586 DOI: 10.1002/nbm.4803] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/21/2022] [Accepted: 07/23/2022] [Indexed: 05/04/2023]
Abstract
T1 mapping is increasingly used in clinical practice and research studies. With limited scan time, existing techniques often have limited spatial resolution, contrast resolution and slice coverage. High fat concentrations yield complex errors in Look-Locker T1 methods. In this study, a dual-echo 2D radial inversion-recovery T1 (DEradIR-T1) technique was developed for fast fat-water separated T1 mapping. The DEradIR-T1 technique was tested in phantoms, 5 volunteers and 28 patients using a 3 T clinical MRI scanner. In our study, simulations were performed to analyze the composite (fat + water) and water-only T1 under different echo times (TE). In standardized phantoms, an inversion-recovery spin echo (IR-SE) sequence with and without fat saturation pulses served as a T1 reference. Parameter mapping with DEradIR-T1 was also assessed in vivo, and values were compared with modified Look-Locker inversion recovery (MOLLI). Bland-Altman analysis and two-tailed paired t-tests were used to compare the parameter maps from DEradIR-T1 with the references. Simulations of the composite and water-only T1 under different TE values and levels of fat matched the in vivo studies. T1 maps from DEradIR-T1 on a NIST phantom (Pcomp = 0.97) and a Calimetrix fat-water phantom (Pwater = 0.56) matched with the references. In vivo T1 was compared with that of MOLLI: R comp 2 = 0.77 ; R water 2 = 0.72 . In this work, intravoxel fat is found to have a variable, echo-time-dependent effect on measured T1 values, and this effect may be mitigated using the proposed DRradIR-T1.
Collapse
Affiliation(s)
- Zhitao Li
- Department of Radiology, Stanford University, Stanford, California, USA
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | - Manoj Mathew
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, California, USA
| | - Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA
| | - Ryan Brunsing
- Department of Radiology, Stanford University, Stanford, California, USA
| | - John M Pauly
- Department of Electrical Engineering, Stanford University, Stanford, California, USA
| | | |
Collapse
|
10
|
Shafieizargar B, Jeurissen B, Poot DHJ, Klein S, Van Audekerke J, Verhoye M, den Dekker AJ, Sijbers J. ADEPT: Accurate Diffusion Echo‐Planar imaging with multi‐contrast shoTs. Magn Reson Med 2022; 89:396-410. [DOI: 10.1002/mrm.29398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 06/10/2022] [Accepted: 07/04/2022] [Indexed: 11/08/2022]
Affiliation(s)
- Banafshe Shafieizargar
- imec‐Vision Lab, Department of Physics University of Antwerp Antwerp Belgium
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
| | - Ben Jeurissen
- imec‐Vision Lab, Department of Physics University of Antwerp Antwerp Belgium
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
| | - Dirk H. J. Poot
- Department of Radiology and Nuclear Medicine, Biomedical Imaging Group Rotterdam Erasmus MC Rotterdam The Netherlands
| | - Stefan Klein
- Department of Radiology and Nuclear Medicine, Biomedical Imaging Group Rotterdam Erasmus MC Rotterdam The Netherlands
| | - Johan Van Audekerke
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
- Bio‐Imaging Lab, Department of Biomedical Sciences University of Antwerp Antwerp Belgium
| | - Marleen Verhoye
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
- Bio‐Imaging Lab, Department of Biomedical Sciences University of Antwerp Antwerp Belgium
| | - Arnold J. den Dekker
- imec‐Vision Lab, Department of Physics University of Antwerp Antwerp Belgium
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
| | - Jan Sijbers
- imec‐Vision Lab, Department of Physics University of Antwerp Antwerp Belgium
- NEURO Research Centre of Excellence University of Antwerp Antwerp Belgium
| |
Collapse
|
11
|
Ismail TF, Strugnell W, Coletti C, Božić-Iven M, Weingärtner S, Hammernik K, Correia T, Küstner T. Cardiac MR: From Theory to Practice. Front Cardiovasc Med 2022; 9:826283. [PMID: 35310962 PMCID: PMC8927633 DOI: 10.3389/fcvm.2022.826283] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 01/17/2022] [Indexed: 01/10/2023] Open
Abstract
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality, causing over 17. 9 million deaths worldwide per year with associated costs of over $800 billion. Improving prevention, diagnosis, and treatment of CVD is therefore a global priority. Cardiovascular magnetic resonance (CMR) has emerged as a clinically important technique for the assessment of cardiovascular anatomy, function, perfusion, and viability. However, diversity and complexity of imaging, reconstruction and analysis methods pose some limitations to the widespread use of CMR. Especially in view of recent developments in the field of machine learning that provide novel solutions to address existing problems, it is necessary to bridge the gap between the clinical and scientific communities. This review covers five essential aspects of CMR to provide a comprehensive overview ranging from CVDs to CMR pulse sequence design, acquisition protocols, motion handling, image reconstruction and quantitative analysis of the obtained data. (1) The basic MR physics of CMR is introduced. Basic pulse sequence building blocks that are commonly used in CMR imaging are presented. Sequences containing these building blocks are formed for parametric mapping and functional imaging techniques. Commonly perceived artifacts and potential countermeasures are discussed for these methods. (2) CMR methods for identifying CVDs are illustrated. Basic anatomy and functional processes are described to understand the cardiac pathologies and how they can be captured by CMR imaging. (3) The planning and conduct of a complete CMR exam which is targeted for the respective pathology is shown. Building blocks are illustrated to create an efficient and patient-centered workflow. Further strategies to cope with challenging patients are discussed. (4) Imaging acceleration and reconstruction techniques are presented that enable acquisition of spatial, temporal, and parametric dynamics of the cardiac cycle. The handling of respiratory and cardiac motion strategies as well as their integration into the reconstruction processes is showcased. (5) Recent advances on deep learning-based reconstructions for this purpose are summarized. Furthermore, an overview of novel deep learning image segmentation and analysis methods is provided with a focus on automatic, fast and reliable extraction of biomarkers and parameters of clinical relevance.
Collapse
Affiliation(s)
- Tevfik F. Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Cardiology Department, Guy's and St Thomas' Hospital, London, United Kingdom
| | - Wendy Strugnell
- Queensland X-Ray, Mater Hospital Brisbane, Brisbane, QLD, Australia
| | - Chiara Coletti
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
| | - Maša Božić-Iven
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
- Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany
| | | | - Kerstin Hammernik
- Lab for AI in Medicine, Technical University of Munich, Munich, Germany
- Department of Computing, Imperial College London, London, United Kingdom
| | - Teresa Correia
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Centre of Marine Sciences, Faro, Portugal
| | - Thomas Küstner
- Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Tübingen, Germany
| |
Collapse
|
12
|
Wang X, Tan Z, Scholand N, Roeloffs V, Uecker M. Physics-based reconstruction methods for magnetic resonance imaging. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2021; 379:20200196. [PMID: 33966457 PMCID: PMC8107652 DOI: 10.1098/rsta.2020.0196] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/01/2021] [Indexed: 05/03/2023]
Abstract
Conventional magnetic resonance imaging (MRI) is hampered by long scan times and only qualitative image contrasts that prohibit a direct comparison between different systems. To address these limitations, model-based reconstructions explicitly model the physical laws that govern the MRI signal generation. By formulating image reconstruction as an inverse problem, quantitative maps of the underlying physical parameters can then be extracted directly from efficiently acquired k-space signals without intermediate image reconstruction-addressing both shortcomings of conventional MRI at the same time. This review will discuss basic concepts of model-based reconstructions and report on our experience in developing several model-based methods over the last decade using selected examples that are provided complete with data and code. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 1'.
Collapse
Affiliation(s)
- Xiaoqing Wang
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Partner Site Göttingen, German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - Zhengguo Tan
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Partner Site Göttingen, German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - Nick Scholand
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Partner Site Göttingen, German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
| | - Volkert Roeloffs
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - Martin Uecker
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
- Partner Site Göttingen, German Centre for Cardiovascular Research (DZHK), Göttingen, Germany
- Cluster of Excellence ‘Multiscale Bioimaging: from Molecular Machines to Networks of Excitable Cells’ (MBExC), University of Göttingen, Göttingen, Germany
- Campus Institute Data Science (CIDAS), University of Göttingen, Göttingen, Germany
| |
Collapse
|