1
|
Wu W. Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction. Magn Reson Med 2024; 92:82-97. [PMID: 38308081 DOI: 10.1002/mrm.30038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Revised: 01/02/2024] [Accepted: 01/16/2024] [Indexed: 02/04/2024]
Abstract
PURPOSE To develop a method for dynamic∆ B 0 $$ \Delta {B}_0 $$ mapping and distortion correction. METHODS A blip-rewound EPI trajectory was developed to acquire multiple 2D EPI images in a single readout with an interleaved order, which allows a short TE difference. A joint multi-echo reconstruction was utilized to exploit the shared information between EPI images. The reconstructed images from each readout are combined to produce a final magnitude image. A∆ B 0 $$ \Delta {B}_0 $$ map is calculated from the phase of these images for distortion correction. The efficacy of the proposed method is assessed with phantom and in vivo experiments. The performance of the proposed method in the presence of subject motion is also investigated. RESULTS Compared to conventional multi-echo EPI, the proposed method allows dynamic∆ B 0 $$ \Delta {B}_0 $$ mapping at matched resolution with a much shorter TR. Phantom and in vivo results show that the proposed method can provide a comparable magnitude image as conventional single-shot EPI. The∆ B 0 $$ \Delta {B}_0 $$ maps calculated from the proposed method are consistent with conventional multi-echo EPI in the phantom experiment. For in vivo experiments, the proposed method provides a more accurate estimation of∆ B 0 $$ \Delta {B}_0 $$ than conventional multi-echo EPI, which is prone to phase wrapping problems due to the long TE difference. In-vivo scan with subject motion shows the proposed dynamic field mapping method can improve the temporal stability of EPI time series compared to gradient echo (GRE) based static field mapping. CONCLUSION The proposed method allows accurate dynamic∆ B 0 $$ \Delta {B}_0 $$ mapping for robust distortion correction without compromising spatial or temporal resolution.
Collapse
Affiliation(s)
- Wenchuan Wu
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
Meyer NK, In MH, Black DF, Campeau NG, Welker KM, Huston J, Halverson MA, Bernstein MA, Trzasko JD. Model-based iterative reconstruction for direct imaging with point spread function encoded echo planar MRI. Magn Reson Imaging 2024; 109:189-202. [PMID: 38490504 PMCID: PMC11075760 DOI: 10.1016/j.mri.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 03/08/2024] [Accepted: 03/08/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND Echo planar imaging (EPI) is a fast measurement technique commonly used in magnetic resonance imaging (MRI), but is highly sensitive to measurement non-idealities in reconstruction. Point spread function (PSF)-encoded EPI is a multi-shot strategy which alleviates distortion, but acquisition of encodings suitable for direct distortion-free imaging prolongs scan time. In this work, a model-based iterative reconstruction (MBIR) framework is introduced for direct imaging with PSF-EPI to improve image quality and acceleration potential. METHODS An MBIR platform was developed for accelerated PSF-EPI. The reconstruction utilizes a subspace representation, is regularized to promote local low-rankedness (LLR), and uses variable splitting for efficient iteration. Comparisons were made against standard reconstructions from prospectively accelerated PSF-EPI data and with retrospective subsampling. Exploring aggressive partial Fourier acceleration of the PSF-encoding dimension, additional comparisons were made against an extension of Homodyne to direct PSF-EPI in numerical experiments. A neuroradiologists' assessment was completed comparing images reconstructed with MBIR from retrospectively truncated data directly against images obtained with standard reconstructions from non-truncated datasets. RESULTS Image quality results were consistently superior for MBIR relative to standard and Homodyne reconstructions. As the MBIR signal model and reconstruction allow for arbitrary sampling of the PSF space, random sampling of the PSF-encoding dimension was also demonstrated, with quantitative assessments indicating best performance achieved through nonuniform PSF sampling combined with partial Fourier. With retrospective subsampling, MBIR reconstructs high-quality images from sub-minute scan datasets. MBIR was shown to be superior in a neuroradiologists' assessment with respect to three of five performance criteria, with equivalence for the remaining two. CONCLUSIONS A novel image reconstruction framework is introduced for direct imaging with PSF-EPI, enabling arbitrary PSF space sampling and reconstruction of diagnostic-quality images from highly accelerated PSF-encoded EPI data.
Collapse
Affiliation(s)
- Nolan K Meyer
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Myung-Ho In
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - David F Black
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Norbert G Campeau
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Kirk M Welker
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - John Huston
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Maria A Halverson
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Matt A Bernstein
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA
| | - Joshua D Trzasko
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| |
Collapse
|
3
|
Chen X, Wu W, Chiew M. Improving robustness of 3D multi-shot EPI by structured low-rank reconstruction of segmented CAIPI sampling for fMRI at 7T. Neuroimage 2023; 267:119827. [PMID: 36572131 PMCID: PMC10933751 DOI: 10.1016/j.neuroimage.2022.119827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 12/15/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022] Open
Abstract
Three-dimensional (3D) encoding methods are increasingly being explored as alternatives to two-dimensional (2D) multi-slice acquisitions in fMRI, particularly in cases where high isotropic resolution is needed. 3D multi-shot EPI acquisition, as the workhorse of 3D fMRI imaging, is susceptible to physiological fluctuations which can induce inter-shot phase variations, and thus reducing the achievable tSNR, negating some of the benefit of 3D encoding. This issue can be particularly problematic at ultra-high fields like 7T, which have more severe off-resonance effects. In this work, we aim to improve the temporal stability of 3D multi-shot EPI at 7T by improving its robustness to inter-shot phase variations. We presented a 3D segmented CAIPI sampling trajectory ("seg-CAIPI") and an improved reconstruction method based on Hankel structured low-rank matrix recovery. Simulation and in-vivo results demonstrate that the combination of the seg-CAIPI sampling scheme and the proposed structured low-rank reconstruction is a promising way to effectively reduce the unwanted temporal variance induced by inter-shot physiological fluctuations, and thus improve the robustness of 3D multi-shot EPI for fMRI.
Collapse
Affiliation(s)
- Xi Chen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
| | - Wenchuan Wu
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom; Physical Sciences, Sunnybrook Research Institute, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Canada
| |
Collapse
|
4
|
Ramos-Llordén G, Lobos RA, Kim TH, Tian Q, Witzel T, Lee HH, Scholz A, Keil B, Yendiki A, Bilgiç B, Haldar JP, Huang SY. High-fidelity, high-spatial-resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra-high gradient strength with structured low-rank echo-planar imaging ghost correction. NMR IN BIOMEDICINE 2023; 36:e4831. [PMID: 36106429 PMCID: PMC9883835 DOI: 10.1002/nbm.4831] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 08/20/2022] [Accepted: 09/11/2022] [Indexed: 06/15/2023]
Abstract
Diffusion magnetic resonance imaging (dMRI) of whole ex vivo human brain specimens enables three-dimensional (3D) mapping of structural connectivity at the mesoscopic scale, providing detailed evaluation of fiber architecture and tissue microstructure at a spatial resolution that is difficult to access in vivo. To account for the short T2 and low diffusivity of fixed tissue, ex vivo dMRI is often acquired using strong diffusion-sensitizing gradients and multishot/segmented 3D echo-planar imaging (EPI) sequences to achieve high spatial resolution. However, the combination of strong diffusion-sensitizing gradients and multishot/segmented EPI readout can result in pronounced ghosting artifacts incurred by nonlinear spatiotemporal variations in the magnetic field produced by eddy currents. Such ghosting artifacts cannot be corrected with conventional correction solutions and pose a significant roadblock to leveraging human MRI scanners with ultrahigh gradients for ex vivo whole-brain dMRI. Here, we show that ghosting-correction approaches that correct for either polarity-related ghosting or shot-to-shot variations in a separate manner are suboptimal for 3D multishot diffusion-weighted EPI experiments in fixed human brain specimens using strong diffusion-sensitizing gradients on the 3-T Connectom MRI scanner, resulting in orientationally biased dMRI estimates. We apply a recently developed advanced k-space reconstruction method based on structured low-rank matrix (SLM) modeling that handles both polarity-related ghosting and shot-to-shot variation simultaneously, to mitigate artifacts in high-angular resolution multishot dMRI data acquired in several fixed human brain specimens at 0.7-0.8-mm isotropic spatial resolution using b-values up to 10,000 s/mm2 and gradient strengths up to 280 mT/m. We demonstrate the improved mapping of diffusion tensor imaging and fiber orientation distribution functions in key neuroanatomical areas distributed across the whole brain using SLM-based EPI ghost correction compared with alternative techniques.
Collapse
Affiliation(s)
- Gabriel Ramos-Llordén
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Rodrigo A. Lobos
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Tae Hyung Kim
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Computer Engineering, Hongik University, Seoul, Republic of Korea
| | - Qiyuan Tian
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | | | - Hong-Hsi Lee
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Alina Scholz
- Institute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany
| | - Boris Keil
- Institute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Philipps University of Marburg, Marburg, Germany
| | - Anastasia Yendiki
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
| | - Berkin Bilgiç
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Justin P. Haldar
- Ming Hsieh Department of Electrical and Computer Engineering, University of Southern California, Los Angeles, California, USA
| | - Susie Y. Huang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA
- Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA
- Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| |
Collapse
|
5
|
Dai E, Mani M, McNab JA. Multi-band multi-shot diffusion MRI reconstruction with joint usage of structured low-rank constraints and explicit phase mapping. Magn Reson Med 2023; 89:95-111. [PMID: 36063492 PMCID: PMC9887994 DOI: 10.1002/mrm.29422] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 08/01/2022] [Accepted: 08/02/2022] [Indexed: 02/02/2023]
Abstract
PURPOSE To develop a joint reconstruction method for multi-band multi-shot diffusion MRI. THEORY AND METHODS Multi-band multi-shot EPI acquisition is an effective approach for high-resolution diffusion MRI, but requires specific algorithms to correct the inter-shot phase variations. The phase correction can be done by first estimating the explicit phase map and then feeding it into the k-space signal formulation model. Alternatively, the phase information can be used indirectly as structured low-rank constraints in k-space. The 2 methods differ in reconstruction accuracy and efficiency. We aim to combine the 2 different approaches for improved image quality and reconstruction efficiency simultaneously, termed "joint usage of structured low-rank constraints and explicit phase mapping" (JULEP). The proposed JULEP reconstruction is tested on both single-band and multi-band, multi-shot diffusion data, with different resolutions and b values. The results of JULEP are compared with conventional methods with explicit phase mapping (i.e., multiplexed sensitivity-encoding [MUSE]) and structured low-rank constraints (i.e., MUSSELS), and another joint reconstruction method (i.e., network estimated artifacts for tempered reconstruction [NEATR]). RESULTS JULEP improves the quality of the navigator and subsequently facilitates the reconstruction of final diffusion images. Compared with all 3 other methods (MUSE, MUSSELS, and NEATR), JULEP mitigates residual structural bias and improves temporal SNRs in the final diffusion image, particularly at high multi-band factors. Compared with MUSSELS, JULEP also improves computational efficiency. CONCLUSION The proposed JULEP method significantly improves the image quality and reconstruction efficiency of multi-band multi-shot diffusion MRI, which can promote a broader application of high-resolution diffusion MRI.
Collapse
Affiliation(s)
- Erpeng Dai
- Department of Radiology, Stanford University, Stanford, CA, United States
| | - Merry Mani
- Department of Radiology, University of Iowa, Iowa City, IA, United States
- Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
| | - Jennifer A McNab
- Department of Radiology, Stanford University, Stanford, CA, United States
| |
Collapse
|