Sengupta S, Glenn A, Rogers B. Prospective head motion correction at 3 Tesla with wireless NMR markers and ultrashort echo navigators. Magn Reson Imaging 2024:110238. [PMID: 39276809 DOI: 10.1016/j.mri.2024.110238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Revised: 08/28/2024] [Accepted: 09/10/2024] [Indexed: 09/17/2024]
Abstract
PURPOSE Prospective motion correction (PMC) with inductively-coupled wireless NMR markers has been shown to be an effective plug-and-play method for dealing with head motion at 7 Tesla [29,30]. However, technical challenges such as one-to-one identification of three wireless markers, generation of hyper-intense marker artifacts and low marker peak SNR in the navigators has limited the adoption of this technique. The goal of this work is to introduce solutions to overcome these issues and extend this technique to PMC for brain imaging at 3 Tesla. METHODS PMC with 6 degrees of freedom (DOF) was implemented using a novel ~8 ms, ultrashort echo time (UTE) navigator in concert with optimally chosen MnCl2 marker samples to minimize marker artifacts. Distinct head coil sensitivities were leveraged to enable identification and tracking of individual markers and a variable flip angle (VFA) scheme and real time filtering were used to boost marker SNR. PMC was performed in 3D T1 weighted brain imaging at 3 Tesla with voluntary head motions in adult volunteers. RESULTS PMC with wireless markers improved image quality in 3D T1 weighted images in all subjects compared to non-motion corrected images for similar motions with no noticeable marker artifacts. Precision of motion tracking was found to be in the range of 0.01-0.06 mm/degrees. Navigator execution had minimal impact on sequence duration. CONCLUSIONS Wireless NMR markers provide an accurate, calibration-free and economical option for 6 DOF PMC in brain imaging across field strengths. Challenges in this technique can be addressed by combining navigator design, sample selection and real time data processing strategies.
Collapse
Affiliation(s)
- Saikat Sengupta
- Vanderbilt University Institute of Imaging Science,Vanderbilt University Medical Center, Nashville, TN 37235, USA; Department of Radiology and Radiological Sciences,Vanderbilt University Medical Center, Nashville, TN 37235, USA.
| | - Antonio Glenn
- Department of Biomedical Engineering, Case Western Reserve University Cleveland, OH 44106, USA
| | - Baxter Rogers
- Vanderbilt University Institute of Imaging Science,Vanderbilt University Medical Center, Nashville, TN 37235, USA; Department of Radiology and Radiological Sciences,Vanderbilt University Medical Center, Nashville, TN 37235, USA
| |
Collapse
|
2
|
Li Z, Ooi MB, Murchison JA, Karis JP. Rapid T 2 ∗ -weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department. Magn Reson Med 2023; 90:2500-2509. [PMID: 37668095 DOI: 10.1002/mrm.29809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 07/07/2023] [Accepted: 07/08/2023] [Indexed: 09/06/2023]
Abstract
PURPOSE Brain MRI is increasingly used in the emergency department (ED), whereT 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI is an essential tool for detecting hemorrhage and stroke. The goal of this study was to develop a rapidT 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI technique capable of correcting motion-induced artifacts, thereby simultaneously improving scan time and motion robustness for ED applications. METHODS A 2D gradient-echo (GRE)-based multishot EPI (msEPI) technique was implemented using a navigator echo for estimating motion-induced errors. Bulk rigid head motion and phase errors were retrospectively corrected using an iterative conjugate gradient approach in the reconstruction pipeline. Three volunteers and select patients were imaged at 3 T and/or 1.5 T with an approximately 1-min full-brain protocol using the proposed msEPI technique and compared to an approximately 3-min standard-of-care GRE protocol to examine its performance. RESULTS Data from volunteers demonstrated that in-plane motion artifacts could be effectively corrected with the proposed msEPI technique, and through-plane motion artifacts could be mitigated. Patient images were qualitatively reviewed by one radiologist without a formal statistical analysis. These results suggested the proposed technique could correct motion-induced artifacts in the clinical setting. In addition, the conspicuity of susceptibility-related lesions using the proposed msEPI technique was comparable, or improved, compared to GRE. CONCLUSION A 1-min full-brainT 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI technique was developed using msEPI with a navigator echo to correct motion-induced errors. Preliminary clinical results suggest faster scans and improved motion robustness and lesion conspicuity make msEPI a competitive alternative to traditionalT 2 * $$ {\mathrm{T}}_2^{\ast } $$ -weighted MRI techniques for brain studies in the ED.
Collapse
Affiliation(s)
- Zhiqiang Li
- Department of Neuroradiology, Barrow Neurological Institute, Phoenix, Arizona, USA
| | | | - James A Murchison
- Department of Neuroradiology, Barrow Neurological Institute, Phoenix, Arizona, USA
| | - John P Karis
- Department of Neuroradiology, Barrow Neurological Institute, Phoenix, Arizona, USA
| |
Collapse
|
3
|
Chen H, Dai K, Zhong S, Zheng J, Zhang X, Yang S, Cao T, Wang C, Karasan E, Frydman L, Zhang Z. High-resolution multi-shot diffusion-weighted MRI combining markerless prospective motion correction and locally low-rank constrained reconstruction. Magn Reson Med 2023; 89:605-619. [PMID: 36198013 DOI: 10.1002/mrm.29468] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 08/10/2022] [Accepted: 09/04/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE Subject head motion is a major challenge in DWI, leading to image blurring, signal losses, and biases in the estimated diffusion parameters. Here, we investigate a combined application of prospective motion correction and spatial-angular locally low-rank constrained reconstruction to obtain robust, multi-shot, high-resolution diffusion-weighted MRI under substantial motion. METHODS Single-shot EPI with retrospective motion correction can mitigate motion artifacts and resolve any mismatching of gradient encoding orientations; however, it is limited by low spatial resolution and image distortions. Multi-shot acquisition strategies could achieve higher resolution and image fidelity but increase the vulnerability to motion artifacts and phase variations related to cardiac pulsations from shot to shot. We use prospective motion correction with optical markerless motion tracking to remove artifacts and reduce image blurring due to bulk motion, combined with locally low-rank regularization to correct for remaining artifacts due to shot-to-shot phase variations. RESULTS The approach was evaluated on healthy adult volunteers at 3 Tesla under different motion patterns. In multi-shot DWI, image blurring due to motion with 20 mm translations and 30° rotations was successfully removed by prospective motion correction, and aliasing artifacts caused by shot-to-shot phase variations were addressed by locally low-rank regularization. The ability of prospective motion correction to preserve the orientational information in DTI without requiring a reorientation of the b-matrix is highlighted. CONCLUSION The described technique is proved to hold valuable potential for mapping brain diffusivity and connectivity at high resolution for studies in subjects/cohorts where motion is common, including neonates, pediatrics, and patients with neurological disorders.
Collapse
Affiliation(s)
- Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Jiaxu Zheng
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.,United Imaging Healthcare, Shanghai, People's Republic of China
| | - Xinyue Zhang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Shasha Yang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Tuoyu Cao
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Chaohong Wang
- United Imaging Healthcare, Shanghai, People's Republic of China
| | - Ekin Karasan
- Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley, California
| | - Lucio Frydman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
4
|
Sprenger T, Kits A, Norbeck O, van Niekerk A, Berglund J, Rydén H, Avventi E, Skare S. NeuroMix-A single-scan brain exam. Magn Reson Med 2021; 87:2178-2193. [PMID: 34904751 DOI: 10.1002/mrm.29120] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 11/23/2021] [Accepted: 11/24/2021] [Indexed: 01/15/2023]
Abstract
PURPOSE Implement a fast, motion-robust pulse sequence that acquires T1 -weighted, T2 -weighted, T2 * -weighted, T2 fluid-attenuated inversion recovery, and DWI data in one run with only one prescription and one prescan. METHODS A software framework was developed that configures and runs several sequences in one main sequence. Based on that framework, the NeuroMix sequence was implemented, containing motion robust single-shot sequences using EPI and fast spin echo (FSE) readouts (without EPI distortions). Optional multi-shot sequences that provide better contrast, higher resolution, or isotropic resolution could also be run within the NeuroMix sequence. An optimized acquisition order was implemented that minimizes times where no data is acquired. RESULTS NeuroMix is customizable and takes between 1:20 and 4 min for a full brain scan. A comparison with the predecessor EPIMix revealed significant improvements for T2 -weighted and T2 fluid-attenuated inversion recovery, while taking only 8 s longer for a similar configuration. The optional contrasts were less motion robust but offered a significant increase in quality, detail, and contrast. Initial clinical scans on 1 pediatric and 1 adult patient showed encouraging image quality. CONCLUSION The single-shot FSE readouts for T2 -weighted and T2 fluid-attenuated inversion recovery and the optional multishot FSE and 3D-EPI contrasts significantly increased diagnostic value compared with EPIMix, allowing NeuroMix to be considered as a standalone brain MRI application.
Collapse
Affiliation(s)
- Tim Sprenger
- MR Applied Science Laboratory Europe, GE Healthcare, Stockholm, Sweden.,Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Annika Kits
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Ola Norbeck
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Adam van Niekerk
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Johan Berglund
- Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Henric Rydén
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Enrico Avventi
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| | - Stefan Skare
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.,Department of Neuroradiology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|