1
|
S. Baptista R, C. C. Moreira M, D. M. Pinheiro L, R. Pereira T, G. Carmona G, P. D. Freire J, A. I. Bastos J, Padilha Lanari Bo A. User-centered design and spatially-distributed sequential electrical stimulation in cycling for individuals with paraplegia. J Neuroeng Rehabil 2022; 19:45. [PMID: 35527249 PMCID: PMC9080548 DOI: 10.1186/s12984-022-01014-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Accepted: 03/28/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
In this work, we share the enhancements made in our system to take part in the CYBATHLON 2020 Global Edition Functional Electrical Stimulation (FES) Bike Race. Among the main improvements, firstly an overhaul, an overhaul of the system and user interface developed with User-centered design principles with remote access to enable telerehabilitation. Secondly, the implementation and experimental comparison between the traditional single electrode stimulation (SES) and spatially distributed sequential stimulation (SDSS) applied for FES Cycling.
Methods
We report on the main aspects of the developed system. To evaluate the user perception of the system, we applied a System Usability Scale (SUS) questionnaire. In comparing SDSS and SES, we collected data from one subject in four sessions, each simulating one race in the CYBATHLON format.
Results
User perception measured with SUS indicates a positive outcome in the developed system. The SDSS trials were superior in absolute and average values to SES regarding total distance covered and velocity. We successfully competed in the CYBATHLON 2020 Global Edition, finishing in 6th position in the FES Bike Race category.
Conclusions
The CYBATHLON format induced us to put the end-user in the center of our system design principle, which was well perceived. However, further improvements are required if the intention is to progress to a commercial product. FES Cycling performance in SDSS trials was superior when compared to SES trials, indicating that this technique may enable faster and possibly longer FES cycling sessions for individuals with paraplegia. More extensive studies are required to assess these aspects.
Collapse
|
2
|
Yacyshyn AF, McNeil CJ. Intrinsic Neuromuscular Fatigability in Humans: The Critical Role of Stimulus Frequency. Exerc Sport Sci Rev 2022; 50:97-103. [PMID: 35025843 DOI: 10.1249/jes.0000000000000283] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Electrically evoked contractions provide insight into intrinsic neuromuscular fatigability and also represent a valuable technique to maintain muscle mass in a clinical setting. To appropriately investigate intrinsic fatigability and design optimal stimulation protocols, it would seem to be crucial to stimulate the muscle at a frequency equivalent to the mean motor unit discharge rate expected at the target force level.
Collapse
Affiliation(s)
- Alexandra F Yacyshyn
- Centre for Heart, Lung and Vascular Health, School of Health and Exercise Sciences, University of British Columbia, Kelowna, BC, Canada
| | | |
Collapse
|
3
|
Ye G, Theventhiran P, Masani K. Effect of Spatially Distributed Sequential Stimulation on Fatigue in Functional Electrical Stimulation Rowing. IEEE Trans Neural Syst Rehabil Eng 2022; 30:999-1008. [DOI: 10.1109/tnsre.2022.3166710] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
4
|
Eladly A, Del Valle J, Minguillon J, Mercadal B, Becerra-Fajardo L, Navarro X, Ivorra A. Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces. J Neural Eng 2020; 17:046037. [PMID: 32717730 DOI: 10.1088/1741-2552/aba99e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achieved. We hypothesize that this could be due to the inability to place the intramuscular electrodes used in interleaved stimulation in locations that minimize overlap amongst the motor units activated by the electrodes. Our objective in the present study was to use independent intramuscular electrodes to compare fatigue induced by interleaved stimulation with that generated by synchronous stimulation at the same initial force and ripple. APPROACH In the medial gastrocnemius muscle of an anesthetized rabbit (n = 3), ten intramuscular hook wire electrodes were inserted at different distances from the nerve entry. Overlap was measured using the refractory technique and only three electrodes were found to be highly independent. After ensuring that forces obtained by both stimulation modalities had the same ripple and magnitude, fatigue induced during interleaved stimulation across three independent distal electrodes was compared to that obtained by synchronously delivering pulses to a single proximal electrode. MAIN RESULTS Contractions evoked by interleaved stimulation exhibited less fatigue than those evoked by synchronous stimulation. Twitch force recruitment curves collected from each of the ten intramuscular electrodes showed frequent intermediate plateaus and the force value at these plateaus decreased as the distance between the electrode and nerve entry increased. SIGNIFICANCE The results indicate that interleaved intramuscular stimulation is preferred over synchronous intramuscular stimulation when fatigue-resistant and smooth forces are desired. In addition, the results suggest that the large muscle compartments innervated by the primary intramuscular nerve branches give rise to progressively smaller independent compartments in subsequent nerve divisions.
Collapse
Affiliation(s)
- Ahmed Eladly
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
5
|
Barss TS, Ainsley EN, Claveria-Gonzalez FC, Luu MJ, Miller DJ, Wiest MJ, Collins DF. Utilizing Physiological Principles of Motor Unit Recruitment to Reduce Fatigability of Electrically-Evoked Contractions: A Narrative Review. Arch Phys Med Rehabil 2017; 99:779-791. [PMID: 28935232 DOI: 10.1016/j.apmr.2017.08.478] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 08/08/2017] [Accepted: 08/16/2017] [Indexed: 10/18/2022]
Abstract
Neuromuscular electrical stimulation (NMES) is used to produce contractions to restore movement and reduce secondary complications for individuals experiencing motor impairment. NMES is conventionally delivered through a single pair of electrodes over a muscle belly or nerve trunk using short pulse durations and frequencies between 20 and 40Hz (conventional NMES). Unfortunately, the benefits and widespread use of conventional NMES are limited by contraction fatigability, which is in large part because of the nonphysiological way that contractions are generated. This review provides a summary of approaches designed to reduce fatigability during NMES, by using physiological principles that help minimize fatigability of voluntary contractions. First, relevant principles of the recruitment and discharge of motor units (MUs) inherent to voluntary contractions and conventional NMES are introduced, and the main mechanisms of fatigability for each contraction type are briefly discussed. A variety of NMES approaches are then described that were designed to reduce fatigability by generating contractions that more closely mimic voluntary contractions. These approaches include altering stimulation parameters, to recruit MUs in their physiological order, and stimulating through multiple electrodes, to reduce MU discharge rates. Although each approach has unique advantages and disadvantages, approaches that minimize MU discharge rates hold the most promise for imminent translation into rehabilitation practice. The way that NMES is currently delivered limits its utility as a rehabilitative tool. Reducing fatigability by delivering NMES in ways that better mimic voluntary contractions holds promise for optimizing the benefits and widespread use of NMES-based programs.
Collapse
Affiliation(s)
- Trevor S Barss
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada
| | - Emily N Ainsley
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Francisca C Claveria-Gonzalez
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, AB, Canada
| | - M John Luu
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
| | - Dylan J Miller
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada
| | - Matheus J Wiest
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Biomechanics Laboratory, Department of Physical Education, Federal University of Santa Catarina, Florianópolis, Brazil
| | - David F Collins
- Human Neurophysiology Laboratory, Faculty of Physical Education and Recreation, University of Alberta, Edmonton, AB, Canada; Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada.
| |
Collapse
|
6
|
Downey RJ, Cheng TH, Bellman MJ, Dixon WE. Switched Tracking Control of the Lower Limb During Asynchronous Neuromuscular Electrical Stimulation: Theory and Experiments. IEEE TRANSACTIONS ON CYBERNETICS 2017; 47:1251-1262. [PMID: 27076479 DOI: 10.1109/tcyb.2016.2543699] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Neuromuscular electrical stimulation (NMES) induces muscle contractions via electrical stimuli. NMES can be used for rehabilitation and to enable functional movements; however, a fundamental limitation is the early onset of fatigue. Asynchronous stimulation is a method that can reduce fatigue by utilizing multiple stimulation channels to segregate and switch between different sets of recruited motor units. However, switching between stimulation channels is challenging due to each channel's differing response to stimulation. To address this challenge, a switched systems analysis is used in the present work to design a controller that allows for instantaneous switching between stimulation channels. The developed controller yields semi-global exponential tracking of a desired angular trajectory for a person's knee-joint. Experiments were conducted in six able-bodied individuals. Compared to conventional stimulation, the results indicate that asynchronous stimulation with the developed controller yields longer durations of successful tracking despite different responses between the stimulation channels.
Collapse
|
7
|
Bergquist AJ, Babbar V, Ali S, Popovic MR, Masani K. Fatigue reduction during aggregated and distributed sequential stimulation. Muscle Nerve 2016; 56:271-281. [PMID: 27862023 DOI: 10.1002/mus.25465] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/09/2016] [Indexed: 11/10/2022]
Abstract
INTRODUCTION Transcutaneous neuromuscular electrical stimulation (NMES) can generate muscle contractions for rehabilitation and exercise. However, NMES-evoked contractions are limited by fatigue when they are delivered "conventionally" (CONV) using a single active electrode. Researchers have developed "sequential" (SEQ) stimulation, involving rotation of pulses between multiple "aggregated" (AGGR-SEQ) or "distributed" (DISTR-SEQ) active electrodes, to reduce fatigue (torque-decline) by reducing motor unit discharge rates. The primary objective was to compare fatigue-related outcomes, "potentiation," "variability," and "efficiency" between CONV, AGGR-SEQ, and DISTR-SEQ stimulation of knee extensors in healthy participants. METHODS Torque and current were recorded during testing with fatiguing trains using each NMES type under isometric and isokinetic (180°/s) conditions. RESULTS Compared with CONV stimulation, SEQ techniques reduced fatigue-related outcomes, increased potentiation, did not affect variability, and reduced efficiency. CONCLUSIONS SEQ techniques hold promise for reducing fatigue during NMES-based rehabilitation and exercise; however, optimization is required to improve efficiency. Muscle Nerve 56: 271-281, 2017.
Collapse
Affiliation(s)
- Austin J Bergquist
- Toronto Rehabilitation Institute, University Health Network, Toronto, Ontario, Canada
| | - Vishvek Babbar
- Toronto Rehabilitation Institute, University Health Network, Toronto, Ontario, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Saima Ali
- Toronto Rehabilitation Institute, University Health Network, Toronto, Ontario, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Milos R Popovic
- Toronto Rehabilitation Institute, University Health Network, Toronto, Ontario, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Kei Masani
- Toronto Rehabilitation Institute, University Health Network, Toronto, Ontario, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Downey RJ, Cheng TH, Bellman MJ, Dixon WE. Closed-Loop Asynchronous Neuromuscular Electrical Stimulation Prolongs Functional Movements in the Lower Body. IEEE Trans Neural Syst Rehabil Eng 2015; 23:1117-27. [PMID: 25935038 DOI: 10.1109/tnsre.2015.2427658] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
Downey RJ, Bellman MJ, Kawai H, Gregory CM, Dixon WE. Comparing the Induced Muscle Fatigue Between Asynchronous and Synchronous Electrical Stimulation in Able-Bodied and Spinal Cord Injured Populations. IEEE Trans Neural Syst Rehabil Eng 2014; 23:964-72. [PMID: 25350934 DOI: 10.1109/tnsre.2014.2364735] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Neuromuscular electrical stimulation (NMES) has been shown to impart a number of health benefits and can be used to produce functional outcomes. However, one limitation of NMES is the onset of NMES-induced fatigue. Multi-channel asynchronous stimulation has been shown to reduce NMES-induced fatigue compared to conventional single-channel stimulation. However, in previous studies in man, the effect of stimulation frequency on the NMES-induced fatigue has not been examined for asynchronous stimulation. Low stimulation frequencies are known to reduce fatigue during conventional stimulation. Therefore, the aim of this study was to examine the fatigue characteristics of high- and low-frequency asynchronous stimulation as well as high- and low-frequency conventional stimulation. Experiments were performed in both able-bodied and spinal cord injured populations. Low frequency asynchronous stimulation is found to have significant fatigue benefits over high frequency asynchronous stimulation as well as high- and low-frequency conventional stimulation, motivating its use for rehabilitation and functional electrical stimulation (FES).
Collapse
|