1
|
Becerra-Fajardo L, Minguillon J, Krob MO, Rodrigues C, González-Sánchez M, Megía-García Á, Galán CR, Henares FG, Comerma A, Del-Ama AJ, Gil-Agudo A, Grandas F, Schneider-Ickert A, Barroso FO, Ivorra A. First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction. J Neuroeng Rehabil 2024; 21:4. [PMID: 38172975 PMCID: PMC10765656 DOI: 10.1186/s12984-023-01295-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 12/12/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. METHODS A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. RESULTS Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. CONCLUSIONS This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.
Collapse
Affiliation(s)
- Laura Becerra-Fajardo
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
| | - Jesus Minguillon
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
- Research Centre for Information and Communications Technologies, University of Granada, Granada, 18014, Spain
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, 18014, Spain
| | - Marc Oliver Krob
- Fraunhofer Institute for Biomedical Engineering IBMT, 66280, Sulzbach, Germany
| | - Camila Rodrigues
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, 28002, Spain
- Systems Engineering and Automation Department, Carlos III University of Madrid, Madrid, 28903, Spain
| | - Miguel González-Sánchez
- Movement Disorders Unit, Department of Neurology, Hospital General Universitario Gregorio Marañón, Madrid, 28007, Spain
| | - Álvaro Megía-García
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Carolina Redondo Galán
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Francisco Gutiérrez Henares
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Albert Comerma
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
| | - Antonio J Del-Ama
- School of Science and Technology, Department of Applied Mathematics, Materials Science and Engineering and Electronic Technology, Rey Juan Carlos University, Móstoles, 28933, Spain
| | - Angel Gil-Agudo
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
- CSIC's Associated RDI Unit 'Unidad De Neurorehabilitación, Biomecánica Y Función Sensitivo-Motora', Madrid, Spain
| | - Francisco Grandas
- Movement Disorders Unit, Department of Neurology, Hospital General Universitario Gregorio Marañón, Madrid, 28007, Spain
| | | | - Filipe Oliveira Barroso
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, 28002, Spain
- CSIC's Associated RDI Unit 'Unidad De Neurorehabilitación, Biomecánica Y Función Sensitivo-Motora', Madrid, Spain
| | - Antoni Ivorra
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain.
- Serra Húnter Fellow Programme, Universitat Pompeu Fabra, Barcelona, 08018, Spain.
| |
Collapse
|
2
|
Fuentes-Martinez VJ, Romero S, Lopez-Gordo MA, Minguillon J, Rodríguez-Álvarez M. Low-Cost EEG Multi-Subject Recording Platform for the Assessment of Students' Attention and the Estimation of Academic Performance in Secondary School. Sensors (Basel) 2023; 23:9361. [PMID: 38067731 PMCID: PMC10708847 DOI: 10.3390/s23239361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/15/2023] [Accepted: 11/20/2023] [Indexed: 12/18/2023]
Abstract
The level of student attention in class greatly affects their academic performance. Teachers typically rely on visual inspection to react to students' attention in time, but this subjective method leads to inconsistencies across classes. Online education exacerbates the issue as students can turn off cameras and microphones to keep their own privacy. To address this, we present a novel, low-cost EEG-based platform for assessing students' attention and estimating their academic performance. In a study involving 34 secondary school students (aged 14 to 16), participants watched an academic video and answered evaluation questions while their EEG activity was recorded using a commercial headset. The results demonstrate a significant correlation (0.53, p-value = 0.003) between the power spectral density (PSD) of the EEG beta band (12-30 Hz) and students' academic performance. Additionally, there was a notable difference in PSD-beta between high and low academic performers. These findings encourage the use of PSD-beta for the immediate and objective assessment of both the student attention and the subsequent academic performance. The platform offers valuable and objective feedback to teachers, enhancing the effectiveness of both face-to-face and online teaching and learning environments.
Collapse
Affiliation(s)
- Victor Juan Fuentes-Martinez
- Department of Computer Engineering, Automation and Robotics, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain;
- Department of Signal Theory, Telematics and Communications, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain; (M.A.L.-G.); (J.M.)
- Neuroengineering and Computation Lab, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain
| | - Samuel Romero
- Department of Computer Engineering, Automation and Robotics, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain;
- Neuroengineering and Computation Lab, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain
| | - Miguel Angel Lopez-Gordo
- Department of Signal Theory, Telematics and Communications, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain; (M.A.L.-G.); (J.M.)
- Neuroengineering and Computation Lab, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain
| | - Jesus Minguillon
- Department of Signal Theory, Telematics and Communications, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain; (M.A.L.-G.); (J.M.)
- Neuroengineering and Computation Lab, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain
| | - Manuel Rodríguez-Álvarez
- Department of Computer Engineering, Automation and Robotics, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18014 Granada, Spain;
| |
Collapse
|
3
|
Martínez‐Cañada P, Perez‐Valero E, Minguillon J, Pelayo F, López‐Gordo MA, Morillas C. Combining aperiodic 1/f slopes and brain simulation: An EEG/MEG proxy marker of excitation/inhibition imbalance in Alzheimer's disease. Alzheimers Dement (Amst) 2023; 15:e12477. [PMID: 37662693 PMCID: PMC10474329 DOI: 10.1002/dad2.12477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 07/27/2023] [Accepted: 08/08/2023] [Indexed: 09/05/2023]
Abstract
INTRODUCTION Accumulation and interaction of amyloid-beta (Aβ) and tau proteins during progression of Alzheimer's disease (AD) are shown to tilt neuronal circuits away from balanced excitation/inhibition (E/I). Current available techniques for noninvasive interrogation of E/I in the intact human brain, for example, magnetic resonance spectroscopy (MRS), are highly restrictive (i.e., limited spatial extent), have low temporal and spatial resolution and suffer from the limited ability to distinguish accurately between different neurotransmitters complicating its interpretation. As such, these methods alone offer an incomplete explanation of E/I. Recently, the aperiodic component of neural power spectrum, often referred to in the literature as the '1/f slope', has been described as a promising and scalable biomarker that can track disruptions in E/I potentially underlying a spectrum of clinical conditions, such as autism, schizophrenia, or epilepsy, as well as developmental E/I changes as seen in aging. METHODS Using 1/f slopes from resting-state spectral data and computational modeling, we developed a new method for inferring E/I alterations in AD. RESULTS We tested our method on recent freely and publicly available electroencephalography (EEG) and magnetoencephalography (MEG) datasets of patients with AD or prodromal disease and demonstrated the method's potential for uncovering regional patterns of abnormal excitatory and inhibitory parameters. DISCUSSION Our results provide a general framework for investigating circuit-level disorders in AD and developing therapeutic interventions that aim to restore the balance between excitation and inhibition.
Collapse
Affiliation(s)
- Pablo Martínez‐Cañada
- Department of Computer EngineeringAutomation and RoboticsUniversity of GranadaGranadaSpain
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
| | - Eduardo Perez‐Valero
- Department of Computer EngineeringAutomation and RoboticsUniversity of GranadaGranadaSpain
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
| | - Jesus Minguillon
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
- Department of Signal TheoryTelematics and CommunicationsUniversity of GranadaGranadaSpain
| | - Francisco Pelayo
- Department of Computer EngineeringAutomation and RoboticsUniversity of GranadaGranadaSpain
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
| | - Miguel A. López‐Gordo
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
- Department of Signal TheoryTelematics and CommunicationsUniversity of GranadaGranadaSpain
| | - Christian Morillas
- Department of Computer EngineeringAutomation and RoboticsUniversity of GranadaGranadaSpain
- Research Centre for Information and Communications Technologies (CITIC)University of GranadaGranadaSpain
| |
Collapse
|
4
|
Perez-Valero E, Morillas C, Lopez-Gordo MA, Minguillon J. Supporting the Detection of Early Alzheimer's Disease with a Four-Channel EEG Analysis. Int J Neural Syst 2023; 33:2350021. [PMID: 36803195 DOI: 10.1142/s0129065723500211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Alzheimer's disease (AD) is the most prevalent form of dementia. Although there is no current cure, medical treatment can help to control its progression. Hence, early-stage diagnosis is crucial to maximize the living standards of the patients. Biochemical markers and medical imaging in combination with neuropsychological tests represent the most extended diagnosis procedure. However, these techniques require specialized personnel and long processing time. Furthermore, the access to some of these techniques is often limited in crowded healthcare systems and rural areas. In this context, electroencephalography (EEG), a non-invasive technique to obtain endogenous brain information, has been proposed for the diagnosis of early-stage AD. Despite the valuable information provided by clinical EEG and high density montages, these approaches are impractical in conditions such as those described above. Consequently, in this study, we evaluated the feasibly of using a reduced EEG montage with only four channels to detect early-stage AD. For this purpose, we involved eight clinically diagnosed AD patients and eight healthy controls. The results we obtained reveal similar accuracies ([Formula: see text]-value[Formula: see text]0.66) for the reduced montage (0.86) and a 16-channel montage (0.87). This suggests that a four-channel wearable EEG system could be an effective tool for supporting early-stage AD detection.
Collapse
Affiliation(s)
- Eduardo Perez-Valero
- Department of Computer Engineering, Automation and Robotics and Research Centre for Information and Communications Technologies, University of Granada, Periodista Daniel Saucedo Aranda, Granada 18071, Spain
| | - Christian Morillas
- Department of Computer Engineering, Automation and Robotics and Research Centre for Information and Communications Technologies, University of Granada, Periodista Daniel Saucedo Aranda, Granada 18071, Spain
| | - Miguel A Lopez-Gordo
- Department of Signal Theory, Telematics and Communications and Research Centre for Information and Communications Technologies, University of Granada, Periodista Daniel Saucedo Aranda, Granada 18071, Spain
| | - Jesus Minguillon
- Department of Signal Theory, Telematics and Communications and Research Centre for Information and Communications Technologies, University of Granada, Periodista Daniel Saucedo Aranda, Granada 18071, Spain
| |
Collapse
|
5
|
García-Moreno A, Comerma-Montells A, Tudela-Pi M, Minguillon J, Becerra-Fajardo L, Ivorra A. Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents. J Neural Eng 2022; 19. [PMID: 36041421 DOI: 10.1088/1741-2552/ac8dc4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 08/30/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. APPROACH These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. MAIN RESULTS The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum-iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. SIGNIFICANCE These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices.
Collapse
Affiliation(s)
- Aracelys García-Moreno
- Department of Information and Communications Technologies, Pompeu Fabra University Department of Information and Communication Technologies, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| | - Albert Comerma-Montells
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| | - Marc Tudela-Pi
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| | - Jesus Minguillon
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| | - Laura Becerra-Fajardo
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| | - Antoni Ivorra
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Carrer Roc Boronat 138, Barcelona, Barcelona, 08018, SPAIN
| |
Collapse
|
6
|
Minguillon J, Tudela-Pi M, Becerra-Fajardo L, Perera-Bel E, Del-Ama AJ, Gil-Agudo A, Megia-Garcia A, Garcia-Moreno A, Ivorra A. Powering Electronic Implants by High Frequency Volume Conduction: In Human Validation. IEEE Trans Biomed Eng 2022; 70:659-670. [PMID: 35994554 DOI: 10.1109/tbme.2022.3200409] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE Wireless power transfer (WPT) is used as an alternative to batteries to accomplish miniaturization in electronic medical implants. However, established WPT methods require bulky parts within the implant or cumbersome external systems, hindering minimally invasive deployments and the development of networks of implants. As an alternative, we propose a WPT approach based on volume conduction of high frequency (HF) current bursts. These currents are applied through external electrodes and are collected by the implants through two electrodes at their opposite ends. This approach avoids bulky components, enabling the development of flexible threadlike implants. METHODS We study in humans if HF (6.78 MHz) current bursts complying with safety standards and applied through two textile electrodes strapped around a limb can provide substantial powers from pairs of implanted electrodes. RESULTS Time averaged electric powers obtained from needle electrodes (diameter = 0.4 mm, length = 3 mm, separation = 30 mm) inserted into arms and lower legs of five healthy participants were 5.9 ± 0.7 mW and 2.4 ± 0.3 mW respectively. We also characterize the coupling between the external system and the implants using personalized two-port impedance models generated from medical images. CONCLUSIONS The results demonstrate that innocuous and imperceptible HF current bursts that flow through the tissues by volume conduction can be used to wirelessly power threadlike implants. SIGNIFICANCE This is the first time that WPT based on volume conduction is demonstrated in humans. This method overcomes the limitations of existing WPT methods in terms of minimal invasiveness and usability.
Collapse
|
7
|
Minguillon J, Volosyak I, Guger C, Tangermann M, Lopez MA. Editorial: Brain-Computer Interfaces: Novel Applications and Interactive Technologies. Front Comput Neurosci 2022; 16:939202. [PMID: 35800256 PMCID: PMC9253767 DOI: 10.3389/fncom.2022.939202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2022] [Accepted: 06/02/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Jesus Minguillon
- Brain-Computer Interfaces Lab, Research Centre for Information and Communications Technologies (CITIC-UGR), Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
| | - Ivan Volosyak
- BCI Lab Kleve, Faculty of Technology and Bionics, Rhine-Waal University of Applied Sciences, Kleve, Germany
| | | | - Michael Tangermann
- Artificial Intelligence Department, Donders Institute, Radboud University, Nijmegen, Netherlands
| | - Miguel Angel Lopez
- Brain-Computer Interfaces Lab, Research Centre for Information and Communications Technologies (CITIC-UGR), Department of Signal Theory, Telematics and Communications, University of Granada, Granada, Spain
- *Correspondence: Miguel Angel Lopez
| |
Collapse
|
8
|
Becerra-Fajardo L, Krob MO, Minguillon J, Rodrigues C, Welsch C, Tudela-Pi M, Comerma A, Oliveira Barroso F, Schneider A, Ivorra A. Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics. J Neuroeng Rehabil 2022; 19:57. [PMID: 35672857 PMCID: PMC9171952 DOI: 10.1186/s12984-022-01033-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 05/19/2022] [Indexed: 11/10/2022] Open
Abstract
Background Implantable neuroprostheses consisting of a central electronic unit wired to electrodes benefit thousands of patients worldwide. However, they present limitations that restrict their use. Those limitations, which are more adverse in motor neuroprostheses, mostly arise from their bulkiness and the need to perform complex surgical implantation procedures. Alternatively, it has been proposed the development of distributed networks of intramuscular wireless microsensors and microstimulators that communicate with external systems for analyzing neuromuscular activity and performing stimulation or controlling external devices. This paradigm requires the development of miniaturized implants that can be wirelessly powered and operated by an external system. To accomplish this, we propose a wireless power transfer (WPT) and communications approach based on volume conduction of innocuous high frequency (HF) current bursts. The currents are applied through external textile electrodes and are collected by the wireless devices through two electrodes for powering and bidirectional digital communications. As these devices do not require bulky components for obtaining power, they may have a flexible threadlike conformation, facilitating deep implantation by injection. Methods We report the design and evaluation of advanced prototypes based on the above approach. The system consists of an external unit, floating semi-implantable devices for sensing and stimulation, and a bidirectional communications protocol. The devices are intended for their future use in acute human trials to demonstrate the distributed paradigm. The technology is assayed in vitro using an agar phantom, and in vivo in hindlimbs of anesthetized rabbits. Results The semi-implantable devices were able to power and bidirectionally communicate with the external unit. Using 13 commands modulated in innocuous 3 MHz HF current bursts, the external unit configured the sensing and stimulation parameters, and controlled their execution. Raw EMG was successfully acquired by the wireless devices at 1 ksps. Conclusions The demonstrated approach overcomes key limitations of existing neuroprostheses, paving the way to the development of distributed flexible threadlike sensors and stimulators. To the best of our knowledge, these devices are the first based on WPT by volume conduction that can work as EMG sensors and as electrical stimulators in a network of wireless devices. Supplementary Information The online version contains supplementary material available at 10.1186/s12984-022-01033-3.
Collapse
|
9
|
Encarnación JA, Cerezuela P, Español I, García MR, Manso C, De la Fuente I, Garrigós N, Viney A, Minguillon J, Surrallés J. Fanconi-like anemia related to a FANCM mutation. Eur J Med Genet 2021; 65:104399. [PMID: 34793962 DOI: 10.1016/j.ejmg.2021.104399] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 06/21/2021] [Accepted: 11/13/2021] [Indexed: 11/03/2022]
Abstract
Fanconi anemia is primarily inherited as an autosomal recessive genetic disorder with common delays in diagnosis and challenging treatments. Fanconi anemia patients have a high risk of developing solid tumors, particularly in the head and neck or anogenital regions. The diagnosis of Fanconi anemia is primarily based on the chromosomal breakage but FA gene sequencing is recommended in all patients with a positive chromosome fragility test. Here, we present a 32-year-old man with advanced tonsil squamous cell carcinoma and fatal toxicity after the first cycle of chemotherapy. No anemia was present. A recent variant mutation if the FANCM gene was detected (c1511_1515delGAGTA (pArg504AsnfsTer29)). Homozygous or double heterozygous pathogenic variants have been reported in FANCM and linked to azoospermia and primary ovarian failure without anemia. Alterations in this gene have also been associated with a genetic predisposition for solid tumors (breast and ovarian cancer) and hematological malignancies (B-cell acute lymphoblastic leukemia). Due to the hypersensitivity of these patients to DNA-damaging agents such as chemotherapy and radiotherapy, surgery is the best treatment option for malignant solid tumors. Dose reductions or alternative regimens of chemotherapy and/or radiotherapy are recommended in FA patients who develop a malignant tumor.
Collapse
Affiliation(s)
- J A Encarnación
- Servicio de Oncología Radioterápica Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain.
| | - P Cerezuela
- Servicio de Oncología Médica Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain
| | - I Español
- Servicio de Hematología y Hemoterapia Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain
| | - M R García
- Servicio de Oncología Médica Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain
| | - C Manso
- Servicio de Medicina Intensiva, Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain
| | - I De la Fuente
- Servicio de Oncología Radioterápica Hospital Clínico Universitario Virgen de la Arrixaca, Murcia, Spain
| | - N Garrigós
- Centro Inmunológico de Alicante, Spain; Servicio de Biología Molecular de Cialab Ribera Salud, Spain
| | - A Viney
- Servicio de Farmacia, Hospital General Universitario Santa Lucía, Cartagena, Spain
| | - J Minguillon
- Genome Instability and DNA Repair Syndromes Group, Sant Pau Biomedical Research Institute (IIB Sant Pau), Join Unit UAB-IR Sant Pau on Genomic Medicine, 08041, Barcelona, Spain; Genetics Department, Hospital de la Santa Creu I Sant Pau, 08041, Barcelona, Spain; Genetics and Microbiology Department, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain; Center for Biomedical Network Research on Rare Diseases (CIBERER), Sant Pau Biomedical Research Institute (IIB Sant Pau), 08041, Barcelona, Spain
| | - J Surrallés
- Genome Instability and DNA Repair Syndromes Group, Sant Pau Biomedical Research Institute (IIB Sant Pau), Join Unit UAB-IR Sant Pau on Genomic Medicine, 08041, Barcelona, Spain; Genetics Department, Hospital de la Santa Creu I Sant Pau, 08041, Barcelona, Spain; Genetics and Microbiology Department, Universitat Autònoma de Barcelona, 08193, Bellaterra, Spain; Center for Biomedical Network Research on Rare Diseases (CIBERER), Sant Pau Biomedical Research Institute (IIB Sant Pau), 08041, Barcelona, Spain
| |
Collapse
|
10
|
Eladly A, Del Valle J, Minguillon J, Mercadal B, Becerra-Fajardo L, Navarro X, Ivorra A. Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces. J Neural Eng 2020; 17:046037. [PMID: 32717730 DOI: 10.1088/1741-2552/aba99e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achieved. We hypothesize that this could be due to the inability to place the intramuscular electrodes used in interleaved stimulation in locations that minimize overlap amongst the motor units activated by the electrodes. Our objective in the present study was to use independent intramuscular electrodes to compare fatigue induced by interleaved stimulation with that generated by synchronous stimulation at the same initial force and ripple. APPROACH In the medial gastrocnemius muscle of an anesthetized rabbit (n = 3), ten intramuscular hook wire electrodes were inserted at different distances from the nerve entry. Overlap was measured using the refractory technique and only three electrodes were found to be highly independent. After ensuring that forces obtained by both stimulation modalities had the same ripple and magnitude, fatigue induced during interleaved stimulation across three independent distal electrodes was compared to that obtained by synchronously delivering pulses to a single proximal electrode. MAIN RESULTS Contractions evoked by interleaved stimulation exhibited less fatigue than those evoked by synchronous stimulation. Twitch force recruitment curves collected from each of the ten intramuscular electrodes showed frequent intermediate plateaus and the force value at these plateaus decreased as the distance between the electrode and nerve entry increased. SIGNIFICANCE The results indicate that interleaved intramuscular stimulation is preferred over synchronous intramuscular stimulation when fatigue-resistant and smooth forces are desired. In addition, the results suggest that the large muscle compartments innervated by the primary intramuscular nerve branches give rise to progressively smaller independent compartments in subsequent nerve divisions.
Collapse
Affiliation(s)
- Ahmed Eladly
- Department of Information and Communication Technologies, Universitat Pompeu Fabra, Barcelona, Spain. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | |
Collapse
|
11
|
|
12
|
Abstract
Stress assessment has been under study in the last years. Both biochemical and physiological markers have been used to measure stress level. In neuroscience, several studies have related modification of stress level to brain activity changes in limbic system and frontal regions, by using non-invasive techniques such as functional magnetic resonance imaging (fMRI) and electroencephalography (EEG). In particular, previous studies suggested that the exhibition or inhibition of certain brain rhythms in frontal cortical areas indicates stress. However, there is no established marker to measure stress level by EEG. In this work, we aimed to prove the usefulness of the prefrontal relative gamma power (RG) for stress assessment. We conducted a study based on stress and relaxation periods. Six healthy subjects performed the Montreal Imaging Stress Task (MIST) followed by a stay within a relaxation room while EEG and electrocardiographic signals were recorded. Our results showed that the prefrontal RG correlated with the expected stress level and with the heart rate (HR; 0.8). In addition, the difference in prefrontal RG between time periods of different stress level was statistically significant (p < 0.01). Moreover, the RG was more discriminative between stress levels than alpha asymmetry, theta, alpha, beta, and gamma power in prefrontal cortex. We propose the prefrontal RG as a marker for stress assessment. Compared with other established markers such as the HR or the cortisol, it has higher temporal resolution. Additionally, it needs few electrodes located at non-hairy head positions, thus facilitating the use of non-invasive dry wearable real-time devices for ubiquitous assessment of stress.
Collapse
Affiliation(s)
- Jesus Minguillon
- Department of Computer Architecture and Technology, University of GranadaGranada, Spain; Research Centre for Information and Communications Technologies, University of GranadaGranada, Spain
| | - Miguel A Lopez-Gordo
- Department of Signal Theory, Telematics and Communications, University of GranadaGranada, Spain; Nicolo AssociationGranada, Spain
| | - Francisco Pelayo
- Department of Computer Architecture and Technology, University of Granada Granada, Spain
| |
Collapse
|
13
|
Minguillon J, Pirondini E, Coscia M, Leeb R, Millan JDR, Van De Ville D, Micera S. Modular organization of reaching and grasping movements investigated using EEG microstates. Annu Int Conf IEEE Eng Med Biol Soc 2015; 2014:2093-6. [PMID: 25570397 DOI: 10.1109/embc.2014.6944029] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
How movements are generated and controlled by the central nervous system (CNS) is still not well understood. In this work, we tested the hypothesis of a modular organization of the brain activity during the execution of voluntary movements. In particular, we extracted meta-stable topographies as a measure for global brain state, so-called microstates, from electroencephalography (EEG) data during pure planar reaching movements as well as reaching and grasping of different objects, and we compared them with those extracted during resting-state. The results showed the emergence of specific EEG microstates related to movement execution. Our results provide evidence about the benefits of EEG microstate analysis for motor control studies and their importance to better understand brain reorganization in neurological pathologies.
Collapse
|