1
|
Becerra-Fajardo L, Minguillon J, Krob MO, Rodrigues C, González-Sánchez M, Megía-García Á, Galán CR, Henares FG, Comerma A, Del-Ama AJ, Gil-Agudo A, Grandas F, Schneider-Ickert A, Barroso FO, Ivorra A. First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction. J Neuroeng Rehabil 2024; 21:4. [PMID: 38172975 PMCID: PMC10765656 DOI: 10.1186/s12984-023-01295-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 12/12/2023] [Indexed: 01/05/2024] Open
Abstract
BACKGROUND Recently we reported the design and evaluation of floating semi-implantable devices that receive power from and bidirectionally communicate with an external system using coupling by volume conduction. The approach, of which the semi-implantable devices are proof-of-concept prototypes, may overcome some limitations presented by existing neuroprostheses, especially those related to implant size and deployment, as the implants avoid bulky components and can be developed as threadlike devices. Here, it is reported the first-in-human acute demonstration of these devices for electromyography (EMG) sensing and electrical stimulation. METHODS A proof-of-concept device, consisting of implantable thin-film electrodes and a nonimplantable miniature electronic circuit connected to them, was deployed in the upper or lower limb of six healthy participants. Two external electrodes were strapped around the limb and were connected to the external system which delivered high frequency current bursts. Within these bursts, 13 commands were modulated to communicate with the implant. RESULTS Four devices were deployed in the biceps brachii and the gastrocnemius medialis muscles, and the external system was able to power and communicate with them. Limitations regarding insertion and communication speed are reported. Sensing and stimulation parameters were configured from the external system. In one participant, electrical stimulation and EMG acquisition assays were performed, demonstrating the feasibility of the approach to power and communicate with the floating device. CONCLUSIONS This is the first-in-human demonstration of EMG sensors and electrical stimulators powered and operated by volume conduction. These proof-of-concept devices can be miniaturized using current microelectronic technologies, enabling fully implantable networked neuroprosthetics.
Collapse
Affiliation(s)
- Laura Becerra-Fajardo
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
| | - Jesus Minguillon
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
- Research Centre for Information and Communications Technologies, University of Granada, Granada, 18014, Spain
- Department of Signal Theory, Telematics and Communications, University of Granada, Granada, 18014, Spain
| | - Marc Oliver Krob
- Fraunhofer Institute for Biomedical Engineering IBMT, 66280, Sulzbach, Germany
| | - Camila Rodrigues
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, 28002, Spain
- Systems Engineering and Automation Department, Carlos III University of Madrid, Madrid, 28903, Spain
| | - Miguel González-Sánchez
- Movement Disorders Unit, Department of Neurology, Hospital General Universitario Gregorio Marañón, Madrid, 28007, Spain
| | - Álvaro Megía-García
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Carolina Redondo Galán
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Francisco Gutiérrez Henares
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
| | - Albert Comerma
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain
| | - Antonio J Del-Ama
- School of Science and Technology, Department of Applied Mathematics, Materials Science and Engineering and Electronic Technology, Rey Juan Carlos University, Móstoles, 28933, Spain
| | - Angel Gil-Agudo
- Biomechanics and Assistive Technology Unit, National Hospital for Paraplegics. Unit of Neurorehabilitation, Biomechanics and Sensory-Motor Function (HNP-SESCAM), Unit associated to the CSIC, Toledo, Spain
- CSIC's Associated RDI Unit 'Unidad De Neurorehabilitación, Biomecánica Y Función Sensitivo-Motora', Madrid, Spain
| | - Francisco Grandas
- Movement Disorders Unit, Department of Neurology, Hospital General Universitario Gregorio Marañón, Madrid, 28007, Spain
| | | | - Filipe Oliveira Barroso
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, 28002, Spain
- CSIC's Associated RDI Unit 'Unidad De Neurorehabilitación, Biomecánica Y Función Sensitivo-Motora', Madrid, Spain
| | - Antoni Ivorra
- Department of Information and Communications Technologies, Universitat Pompeu Fabra, Barcelona, 08018, Spain.
- Serra Húnter Fellow Programme, Universitat Pompeu Fabra, Barcelona, 08018, Spain.
| |
Collapse
|