Bogner W, Chmelik M, Andronesi OC, Sorensen AG, Trattnig S, Gruber S. In vivo 31P spectroscopy by fully adiabatic extended image selected in vivo spectroscopy: a comparison between 3 T and 7 T. Magn Reson Med 2011; 66:923-30. [PMID: 21446033 DOI: 10.1002/mrm.22897] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2010] [Revised: 02/01/2011] [Accepted: 02/06/2011] [Indexed: 01/11/2023]
Abstract
An improved image selected in vivo spectroscopy (ISIS) sequence for localized (31)P magnetic resonance spectroscopy at 7 T was developed. To reduce errors in localization accuracy, adiabatic excitation, gradient offset independent adiabatic inversion pulses, and a special extended ISIS ordering scheme were used. The localization accuracy of extended ISIS was investigated in phantoms. The possible spectral quality and reproducibility in vivo was explored in a volunteer (brain, muscle, and liver). A comparison between 3 T and 7 T was performed in five volunteers. Adiabatic extended ISIS provided high spectral quality and accurate localization. The contamination in phantom experiments was only ∼5%, even if a pulse repetition time ∼ 1.2·T(1) was chosen to maximize the signal-to-noise ratio per unit time. High reproducibility was found in the calf muscle for 2.5 cm isotropic voxels at 7 T. When compared with 3 T, localized (31)P magnetic resonance spectroscopy in the human calf muscle at 7 T provided ∼3.2 times higher signal-to-noise ratio (as judged from phosphocreatine peak amplitude in frequency domain after matched filtering). At 7 T, extended ISIS allowed the performance of high-quality localized (31)P magnetic resonance spectroscopy in a short measurement time (∼3 to 4 min) and isotropic voxel sizes of ∼2.5 to 3 cm. With such short measurement times, localized (31)P magnetic resonance spectroscopy has the potential to be applied not only for clinical research but also for routine clinical practice.
Collapse
Affiliation(s)
- W Bogner
- Department of Radiology, MR Center of Excellence, Medical University Vienna, Vienna, Austria
| | | | | | | | | | | |
Collapse
|
2
|
Abstract
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
Collapse
Affiliation(s)
- Stephen F Keevil
- Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, Guy's Hospital, London, SE1 9RT, UK.
| |
Collapse
|
3
|
Ljungberg M, Starck G, Vikhoff-Baaz B, Alpsten M, Ekholm S, Forssell-Aronsson E. The magnitude of signal errors introduced by ISIS in quantitative 31P MRS. MAGMA (NEW YORK, N.Y.) 2002; 14:30-8. [PMID: 11796250 DOI: 10.1007/bf02668184] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
It is well known that the quality of a quantitative 31P MRS measurement relies largely on the performance of the volume selection method, and that image selected in vivo spectroscopy (ISIS) suffers from contaminating signal caused mostly by T1 smearing. However, these signal errors and their magnitude are seldom addressed in clinical studies. The aim of this study was therefore to investigate the magnitude of signal errors in 31P MRS when using ISIS. The results from the measurements with a homogeneous head phantom are as follows: at low TR/T1 ratios the contamination increases rapidly, especially for small (<27 cm3) VOI sizes; at TR/T1=1, the signal from a 27 cm3 VOI was 20% too high, and from an 8 cm3 VOI 150% too high. The signal obtained from different VOI positions varied between 80 and 127%. The signal varied linearly with the 31P concentration in the object. However, a too high signal was obtained when the concentration was lower in the region of interest (inner container) than in the rest of the phantom. The agreement between the simulations and measurements shows that the results of this study are generally applicable to the measurement geometry and the ISIS experiment order rather than being specific for the MR system studied. The errors obtained both experimentally and in computer simulations are too large to be ignored in clinical studies using the ISIS pulse sequence.
Collapse
Affiliation(s)
- Maria Ljungberg
- Department of Radiation Physics, Göteborg University, Sahlgrenska University Hospital, 413 45, Göteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
4
|
Keevil SF, Newbold MC. The performance of volume selection sequences for in vivo NMR spectroscopy: implications for quantitative MRS. Magn Reson Imaging 2001; 19:1217-26. [PMID: 11755732 DOI: 10.1016/s0730-725x(01)00449-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Previous work has demonstrated that deficiencies in volume selection sequences used in magnetic resonance spectroscopy may compromise the quality of the spectra obtained. In this paper, further studies on the ISIS and PRESS sequences are presented. Under conditions of partial saturation, ISIS can exhibit serious contamination with extraneous signal, particularly when a small volume of interest (VOI) is selected. ISIS protocols should therefore use VOIs that are large relative to the target volume, and repetition times that are as long as practicable. In PRESS, contamination is found to be minimised by using a VOI that is small relative to the target volume, and to be independent of repetition time. PRESS performance is also independent of echo time, except when very short echo times are used. These results are consistent with previously published work on ISIS and PRESS, and it is now possible to establish generic features of these sequences and to understand the implications for quantitative spectroscopy. T(1)-weighting of contamination in ISIS can compromise both relative and absolute quantification techniques in several respects. Contamination in PRESS is largely independent of relaxation times and would be easier to model and correct for in the context of quantitative spectroscopy.
Collapse
Affiliation(s)
- S F Keevil
- Department of Radiological Sciences, Guy's, King's and St Thomas' School of Medicine, King's College London, Guy's Campus, London, SE1 9RT, UK.
| | | |
Collapse
|
5
|
Starck G, Ljungberg M, Vikhoff-Baaz B, Alpsten M, Ekholm S, Forssell-Aronsson E. Point-wise measurements of MRS volume selection performance are insensitive to magnetic susceptibility effects of phantom materials. Magn Reson Imaging 2000; 18:867-74. [PMID: 11027881 DOI: 10.1016/s0730-725x(00)00184-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The purpose was to analyse magnetic susceptibility effects on accuracy of point-wise measurements of signal profiles in the assessment of MRS volume selection performance. An existing phantom design consisting of a sphere with a movable signal source was used for the investigation. The influence from the phantom on magnetic field homogeneity was measured with phase sensitive 1H imaging and 31P spectroscopy on a 1.5 T whole body MR system. The susceptibility effects for such a phantom design can be separated in 1/ A variation in the background magnetic field, which is caused by the stationary structures and has a significant influence on spatial accuracy. 2/ A magnetic field distortion, which is caused by the movable signal source and has very little influence on accuracy. The spatial inaccuracy due to susceptibility effects in this phantom, was 0.03 mm for positions of the signal source covering a 40-mm VOI. Susceptibility effects from the movable signal source were substantial but had very little influence on spatial accuracy. Still, improvements of this phantom design are possible. Point-wise measurements using a phantom with a movable signal source is inherently insensitive to susceptibility effects from the signal source and permits accurate signal profile measurements of high spatial (sub-mm) resolution.
Collapse
Affiliation(s)
- G Starck
- Division of Medical Physics and Medical Engineering, Sahlgrenska University Hospital, S-413 45, Göteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
6
|
Vikhoff-Baaz B, Ljungberg M, Starck G, Forssell-Aronsson E, Jönsson L, Alpsten M, Ekholm S. Performance of 2D 1H spectroscopic imaging of the brain: some practical considerations regarding the measurement procedure. Magn Reson Imaging 1999; 17:919-31. [PMID: 10402599 DOI: 10.1016/s0730-725x(99)00023-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
This paper deals with some of the practical considerations in the planning and performance of chemical shift imaging (MRSI or CSI) of the brain. It contains some aspects of 1) the imaging procedure (MRI), i.e., suggestions of an imaging protocol useful for the spectroscopic planning, 2) the planning of the spectroscopic volume, i.e., size and position, 3) evaluation and judgment of the preparation results, and 4) evaluation of the MRSI images. The paper also contains suggestions of developmental work and quality assessment to be done before patient studies are begun. Examples are given for MRSI studies of temporal lobe epilepsy. Several of the aspects described are obvious for the experienced spectroscopist but may be useful in the initiation of MRSI. The goal of this paper was to share our experiences of how to achieve high quality MRSI, experiences that we would had been grateful for in our prelude of MRSI experiments.
Collapse
Affiliation(s)
- B Vikhoff-Baaz
- Department of Radiation Physics, Göteborg University, Sweden.
| | | | | | | | | | | | | |
Collapse
|
7
|
Bovée W, Canese R, Decorps M, Forssell-Aronsson E, Le Fur Y, Howe F, Karlsen O, Knijn A, Kontaxis G, Kügel H, McLean M, Podo F, Slotboom J, Vikhoff B, Ziegler A. Absolute metabolite quantification by in vivo NMR spectroscopy: IV. Multicentre trial on MRSI localisation tests. Magn Reson Imaging 1998; 16:1113-25. [PMID: 9839995 DOI: 10.1016/s0730-725x(98)00120-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes. Results of a European multi-centre trial show that this approach is suited for assessment of MRSI localization performance.
Collapse
Affiliation(s)
- W Bovée
- Department of Applied Physics, University of Technology, Delft, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Ljungberg M, Starck G, Vikhoff-Baaz B, Forssell-Aronsson E, Alpsten M, Ekholm S. Signal profile measurements of single- and double-volume acquisitions with image-selected in vivo spectroscopy for 31P magnetic resonance spectroscopy. Magn Reson Imaging 1998; 16:829-37. [PMID: 9811147 DOI: 10.1016/s0730-725x(98)00007-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The volume-selection performance was studied for single- and double-volume-of-interest (VOI) acquisition with the volume-selection method image-selected in vivo spectroscopy for 31P magnetic resonance spectroscopy. High-resolution signal profiles were measured using a phantom simulating a brain. Inside the phantom there was a small, remotely controlled, movable signal source filled with ortho-phosphoric acid. Signal profiles of the VOI were measured in three perpendicular directions for 1VOI (single VOI) and 2VOI (double VOI) acquisition. The measured signal profiles for both acquisitions were very similar, but they showed a discrepancy with regard to the intended VOI (iVOI). The transition regions were on average 3.8 mm and the average full width at half maximum of the signal profile was 30 mm for an iVOI size of 30*30*30 (mm3). No displacement was observed in the signal profiles. To avoid overlapping signal profiles, the minimum separation between two iVOIs was found to be 10 mm in our magnetic resonance (MR) system. A substantial negative signal contribution from regions outside the iVOI was measured in the y-direction for 1VOI acquisition and one of the two VOIs in 2VOI acquisition. The other VOI in 2VOI acquisition exhibited only minor contamination. The measurements presented underline the importance of detailed knowledge on the volume selection performance in in vivo magnetic resonance spectroscopy.
Collapse
Affiliation(s)
- M Ljungberg
- Department of Radiation Physics, Göteborg University, Sahlgrenska University Hospital, Sweden.
| | | | | | | | | | | |
Collapse
|
9
|
Lamb HJ, Beyerbacht HP, Ouwerkerk R, Doornbos J, Pluim BM, van der Wall EE, van der Laarse A, de Roos A. Metabolic response of normal human myocardium to high-dose atropine-dobutamine stress studied by 31P-MRS. Circulation 1997; 96:2969-77. [PMID: 9386164 DOI: 10.1161/01.cir.96.9.2969] [Citation(s) in RCA: 53] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND 31P-MRS during cardiac stress may provide (patho)physiological insights into the high-energy phosphate metabolism of the myocardium. Accordingly, the purpose of the present study was to determine the metabolic response of normal human myocardium to severe atropine-dobutamine (A-D) stress. To corroborate the results from the present in vivo study, a 31P-MRS experiment was performed with a moving phantom to simulate respiratory motion. METHODS AND RESULTS The phantom experiment showed no relation (P=.371) between the intensity ratio of two separate phosphate peaks and amplitude of phantom excursions. The phosphocreatine (PCr) and ATP signal strength and the PCr/ATP ratio were determined from the left ventricular wall in 20 healthy subjects (posttest likelihood for coronary artery disease was <2.5%) with 31P-MRS at rest and during high-dose A-D stress (rate-pressure product increased threefold). Stress-induced changes were -21% for PCr (P<.001) and -9% for ATP (P<.05). The average PCr/ATP value at rest was 1.42+/-0.18 and decreased by 14% to 1.22+/-0.20 during stress (P<.001). CONCLUSIONS The phantom experiment shows that the in vivo decrease of myocardial PCr/ATP due to high-dose A-D stress we observed is not a motion artifact. Consequently, this indicates that myocardial high-energy phosphate metabolism of the normal human heart is altered at high workloads.
Collapse
Affiliation(s)
- H J Lamb
- Department of Radiology, Leiden University Medical Center, and the Heart Lung Institute, The Netherlands
| | | | | | | | | | | | | | | |
Collapse
|