Najac C, Boer VO, Kan HE, Webb AG, Ronen I. Improved detection limits of J-coupled neurometabolites in the human brain at 7 T with a J-refocused sLASER sequence. NMR IN BIOMEDICINE 2022; 35:e4801. [PMID: 35833462 PMCID: PMC9788253 DOI: 10.1002/nbm.4801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 07/02/2022] [Accepted: 07/12/2022] [Indexed: 06/15/2023]
Abstract
In a standard spin echo, the time evolution due to homonuclear couplings is not reversed, leading to echo time (TE)-dependent modulation of the signal amplitude and signal loss in the case of overlapping multiplet resonances. This has an adverse effect on quantification of several important metabolites such as glutamate and glutamine. Here, we propose a J-refocused variant of the sLASER sequence (J-sLASER) to improve quantification of J-coupled metabolites at ultrahigh field (UHF). The use of the sLASER sequence is particularly advantageous at UHF as it minimizes chemical shift displacement error and results in relatively homogenous refocusing. We simulated the MRS signal from brain metabolites over a broad range of TE values with sLASER and J-sLASER, and showed that the signal of J-coupled metabolites was increased with J-sLASER with TE values up to ~80 ms. We further simulated "brain-like" spectra with both sequences at the shortest TE available on our scanner. We showed that, despite the slightly longer TE, the J-sLASER sequence results in significantly lower Cramer-Rao lower bounds (CRLBs) for J-coupled metabolites compared with those obtained with sLASER. Following phantom validation, we acquired spectra from two brain regions in 10 healthy volunteers (age 38 ± 15 years) using both sequences. We showed that using J-sLASER results in a decrease of CRLBs for J-coupled metabolites. In particular, we measured a robust ~38% decrease in the mean CRLB (glutamine) in parietal white matter and posterior cingulate cortex (PCC). We further showed, in 10 additional healthy volunteers (age 34 ± 15 years), that metabolite quantification following two separate acquisitions with J-sLASER in the PCC was repeatable. The improvement in quantification of glutamine may in turn improve the independent quantification of glutamate, the main excitatory neurotransmitter in the brain, and will simultaneously help to track possible modulations of glutamine, which is a key player in the glutamatergic cycle in astrocytes.
Collapse
Affiliation(s)
- Chloé Najac
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Vincent O. Boer
- Danish Research Centre for Magnetic ResonanceCopenhagen University Hospital HvidovreHvidovreDenmark
| | - Hermien E. Kan
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Andrew G. Webb
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Itamar Ronen
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| |
Collapse
|
2
|
Lanz B, Abaei A, Braissant O, Choi IY, Cudalbu C, Henry PG, Gruetter R, Kara F, Kantarci K, Lee P, Lutz NW, Marjańska M, Mlynárik V, Rasche V, Xin L, Valette J. Magnetic resonance spectroscopy in the rodent brain: Experts' consensus recommendations. NMR IN BIOMEDICINE 2020; 34:e4325. [PMID: 33565219 PMCID: PMC9429976 DOI: 10.1002/nbm.4325] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 03/29/2020] [Accepted: 04/30/2020] [Indexed: 05/21/2023]
Abstract
In vivo MRS is a non-invasive measurement technique used not only in humans, but also in animal models using high-field magnets. MRS enables the measurement of metabolite concentrations as well as metabolic rates and their modifications in healthy animals and disease models. Such data open the way to a deeper understanding of the underlying biochemistry, related disturbances and mechanisms taking place during or prior to symptoms and tissue changes. In this work, we focus on the main preclinical 1H, 31P and 13C MRS approaches to study brain metabolism in rodent models, with the aim of providing general experts' consensus recommendations (animal models, anesthesia, data acquisition protocols). An overview of the main practical differences in preclinical compared with clinical MRS studies is presented, as well as the additional biochemical information that can be obtained in animal models in terms of metabolite concentrations and metabolic flux measurements. The properties of high-field preclinical MRS and the technical limitations are also described.
Collapse
Affiliation(s)
- Bernard Lanz
- Laboratory for Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom
| | - Alireza Abaei
- Core Facility Small Animal Imaging, Ulm University, Ulm, Germany
| | - Olivier Braissant
- Service of Clinical Chemistry, University of Lausanne and University Hospital of Lausanne, Lausanne, Switzerland
| | - In-Young Choi
- Department of Neurology, University of Kansas Medical Center, Kansas City, Kansas, US
| | - Cristina Cudalbu
- Centre d’Imagerie Biomedicale (CIBM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Pierre-Gilles Henry
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, US
| | - Rolf Gruetter
- Laboratory for Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Firat Kara
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, US
| | - Kejal Kantarci
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, US
| | - Phil Lee
- Department of Radiology, University of Kansas Medical Center, Kansas City, Kansas, US
| | | | - Małgorzata Marjańska
- Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, US
| | - Vladimír Mlynárik
- High Field MR Centre, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Volker Rasche
- Core Facility Small Animal Imaging, Ulm University, Ulm, Germany
| | - Lijing Xin
- Centre d’Imagerie Biomedicale (CIBM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Julien Valette
- Commissariat à l’Energie Atomique et aux Energies Alternatives, MIRCen, Fontenay-aux-Roses, France
- Neurodegenerative Diseases Laboratory, Centre National de la Recherche Scientifique, Université Paris-Sud, Université Paris-Saclay, UMR 9199, Fontenay-aux-Roses, France
| | | |
Collapse
|
3
|
Chen H, De Feyter HM, Brown PB, Rothman DL, Cai S, de Graaf RA. Comparison of direct 13C and indirect 1H-[ 13C] MR detection methods for the study of dynamic metabolic turnover in the human brain. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2017; 283:33-44. [PMID: 28869920 DOI: 10.1016/j.jmr.2017.08.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 08/02/2017] [Accepted: 08/10/2017] [Indexed: 06/07/2023]
Abstract
A wide range of direct 13C and indirect 1H-[13C] MR detection methods exist to probe dynamic metabolic pathways in the human brain. Choosing an optimal detection method is difficult as sequence-specific features regarding spatial localization, broadband decoupling, spectral resolution, power requirements and sensitivity complicate a straightforward comparison. Here we combine density matrix simulations with experimentally determined values for intrinsic 1H and 13C sensitivity, T1 and T2 relaxation and transmit efficiency to allow selection of an optimal 13C MR detection method for a given application and magnetic field. The indirect proton-observed, carbon-edited (POCE) detection method provides the highest accuracy at reasonable RF power deposition both at 4T and 7T. The various polarization transfer methods all have comparable performances, but may become infeasible at 7T due to the high RF power deposition. 2D MR methods have limited value for the metabolites considered (primarily glutamate, glutamine and γ-amino butyric acid (GABA)), but may prove valuable when additional information can be extracted, such as isotopomers or lipid composition. While providing the lowest accuracy, the detection of non-protonated carbons is the simplest to implement with the lowest RF power deposition. The magnetic field homogeneity is one of the most important parameters affecting the detection accuracy for all metabolites and all acquisition methods.
Collapse
Affiliation(s)
- Hao Chen
- Magnetic Resonance Research Center, Department of Radiology and Biomedical Imaging, Yale University, School of Medicine, New Haven, CT, USA; Department of Electronic Science, Xiamen University, Xiamen, Fujian, China
| | - Henk M De Feyter
- Magnetic Resonance Research Center, Department of Radiology and Biomedical Imaging, Yale University, School of Medicine, New Haven, CT, USA
| | - Peter B Brown
- Magnetic Resonance Research Center, Department of Radiology and Biomedical Imaging, Yale University, School of Medicine, New Haven, CT, USA
| | - Douglas L Rothman
- Magnetic Resonance Research Center, Department of Radiology and Biomedical Imaging, Yale University, School of Medicine, New Haven, CT, USA
| | - Shuhui Cai
- Department of Electronic Science, Xiamen University, Xiamen, Fujian, China
| | - Robin A de Graaf
- Magnetic Resonance Research Center, Department of Radiology and Biomedical Imaging, Yale University, School of Medicine, New Haven, CT, USA.
| |
Collapse
|
4
|
Liu Z, Dimitrov IE, Lenkinski RE, Hajibeigi A, Vinogradov E. UCEPR: Ultrafast localized CEST-spectroscopy with PRESS in phantoms and in vivo. Magn Reson Med 2016; 75:1875-85. [PMID: 26033357 PMCID: PMC4663188 DOI: 10.1002/mrm.25780] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 04/02/2015] [Accepted: 04/27/2015] [Indexed: 11/10/2022]
Abstract
PURPOSE Chemical exchange saturation transfer (CEST) is a contrast mechanism enhancing low-concentration molecules through saturation transfer from their exchangeable protons to bulk water. Often many scans are acquired to form a Z-spectrum, making the CEST method time-consuming. Here, an ultrafast localized CEST-spectroscopy with PRESS (UCEPR) is proposed to obtain the entire Z-spectrum of a voxel using only two scans, significantly accelerating CEST. THEORY AND METHODS The approach combines ultrafast nonlocalized CEST spectroscopy with localization using PRESS. A field gradient is applied concurrently with the saturation pulse producing simultaneous saturation of all Z-spectrum frequencies that are also spatially encoded. A readout gradient during data acquisition resolves the spatial dependence of the CEST responses into frequency. UCEPR was tested on a 3T scanner both in phantoms and in vivo. RESULTS In phantoms, a fast Z-spectroscopy acquisition of multiple pH-variant iopamidol samples was achieved with four- to seven-fold acceleration as compared to the conventional CEST methods. In vivo, amide proton transfer (APT) in white matter of healthy human brain was measured rapidly in 48 s and with high frequency resolution (≤ 0.2 ppm). CONCLUSION Compared with conventional CEST methods, UCEPR has the advantage of rapidly acquiring high-resolution Z-spectra. Potential in vivo applications include ultrafast localized Z-spectroscopy, quantitative, or dynamic CEST studies.
Collapse
Affiliation(s)
- Zheng Liu
- Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Division of Neuroscience, Oregon National Primate Research Center, Oregon Health & Science University, Beaverton, Oregon, USA
| | - Ivan E. Dimitrov
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Philips Medical Systems, Highland Heights, Ohio, USA
| | - Robert E. Lenkinski
- Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Asghar Hajibeigi
- Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| | - Elena Vinogradov
- Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
5
|
Wei Z, Lin L, Wang C, Yang J, Liu G, Zhong J, Lin Y, Chen Z. High-resolution localized spatiotemporal encoding correlated spectra under inhomogeneous magnetic fields via asymmetrical gradient encoding/decoding. NMR IN BIOMEDICINE 2015; 28:210-216. [PMID: 25504877 DOI: 10.1002/nbm.3241] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2014] [Revised: 11/03/2014] [Accepted: 11/06/2014] [Indexed: 06/04/2023]
Abstract
Applications of conventional localized nuclear magnetic resonance correlated spectroscopy are restrained by long acquisition times and poor performance under inhomogeneous magnetic fields. Here, a method that combines the spatiotemporal encoding technique with the localization technique and implements the encoding and decoding in unison with suitable asymmetrical gradients is proposed to obtain high-resolution localized correlated spectra under inhomogeneous fields in greatly reduced times. Experiments on phantom solutions prove its insensitivity to linear field inhomogeneities along three orthogonal axes. Moreover, this method is applied to adipose study of marrow tissue with resolution improvements. The proposed method may offer promising perspectives for fast analyses of biological tissues.
Collapse
Affiliation(s)
- Zhiliang Wei
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory for the Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China
| | | | | | | | | | | | | | | |
Collapse
|