1
|
Giurgiu M, Timm I, Becker M, Schmidt S, Wunsch K, Nissen R, Davidovski D, Bussmann JBJ, Nigg CR, Reichert M, Ebner-Priemer UW, Woll A, von Haaren-Mack B. Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review. JMIR Mhealth Uhealth 2022; 10:e36377. [PMID: 35679106 PMCID: PMC9227659 DOI: 10.2196/36377] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 04/27/2022] [Accepted: 04/29/2022] [Indexed: 12/13/2022] Open
Abstract
Background Wearable technology is a leading fitness trend in the growing commercial industry and an established method for collecting 24-hour physical behavior data in research studies. High-quality free-living validation studies are required to enable both researchers and consumers to make guided decisions on which study to rely on and which device to use. However, reviews focusing on the quality of free-living validation studies in adults are lacking. Objective This study aimed to raise researchers’ and consumers’ attention to the quality of published validation protocols while aiming to identify and compare specific consistencies or inconsistencies between protocols. We aimed to provide a comprehensive and historical overview of which wearable devices have been validated for which purpose and whether they show promise for use in further studies. Methods Peer-reviewed validation studies from electronic databases, as well as backward and forward citation searches (1970 to July 2021), with the following, required indicators were included: protocol must include real-life conditions, outcome must belong to one dimension of the 24-hour physical behavior construct (intensity, posture or activity type, and biological state), the protocol must include a criterion measure, and study results must be published in English-language journals. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool with 9 questions separated into 4 domains (patient selection or study design, index measure, criterion measure, and flow and time). Results Of the 13,285 unique search results, 222 (1.67%) articles were included. Most studies (153/237, 64.6%) validated an intensity measure outcome such as energy expenditure. However, only 19.8% (47/237) validated biological state and 15.6% (37/237) validated posture or activity-type outcomes. Across all studies, 163 different wearables were identified. Of these, 58.9% (96/163) were validated only once. ActiGraph GT3X/GT3X+ (36/163, 22.1%), Fitbit Flex (20/163, 12.3%), and ActivPAL (12/163, 7.4%) were used most often in the included studies. The percentage of participants meeting the quality criteria ranged from 38.8% (92/237) to 92.4% (219/237). On the basis of our classification tree to evaluate the overall study quality, 4.6% (11/237) of studies were classified as low risk. Furthermore, 16% (38/237) of studies were classified as having some concerns, and 72.9% (173/237) of studies were classified as high risk. Conclusions Overall, free-living validation studies of wearables are characterized by low methodological quality, large variability in design, and focus on intensity. Future research should strongly aim at biological state and posture or activity outcomes and strive for standardized protocols embedded in a validation framework. Standardized protocols for free-living validation embedded in a framework are urgently needed to inform and guide stakeholders (eg, manufacturers, scientists, and consumers) in selecting wearables for self-tracking purposes, applying wearables in health studies, and fostering innovation to achieve improved validity.
Collapse
Affiliation(s)
- Marco Giurgiu
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany.,Department of Psychiatry and Psychotherapy, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Irina Timm
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Marlissa Becker
- Unit Physiotherapy, Department of Orthopedics, Erasmus MC, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Steffen Schmidt
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Kathrin Wunsch
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Rebecca Nissen
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Denis Davidovski
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Johannes B J Bussmann
- Department of Rehabilitation Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, Netherlands
| | - Claudio R Nigg
- Health Science Department, Institute of Sport Science, University of Bern, Bern, Switzerland
| | - Markus Reichert
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany.,Department of Psychiatry and Psychotherapy, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.,Department of eHealth and Sports Analytics, Faculty of Sport Science, Ruhr-University Bochum, Bochum, Germany
| | - Ulrich W Ebner-Priemer
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany.,Department of Psychiatry and Psychotherapy, Central Institute of Mental Health, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Alexander Woll
- Department of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany
| | - Birte von Haaren-Mack
- Department of Health and Social Psychology, Institute of Psychology, German Sport University, Cologne, Germany
| |
Collapse
|
2
|
Vietheer A, Kiserud T, Lie RT, Haaland ØA, Kessler J. Sleep and physical activity from before conception to the end of pregnancy in healthy women: a longitudinal actigraphy study. Sleep Med 2021; 83:89-98. [PMID: 33991895 DOI: 10.1016/j.sleep.2021.04.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/22/2021] [Accepted: 04/20/2021] [Indexed: 12/12/2022]
Abstract
BACKGROUND Sleep and physical activity changes are common in pregnancy, but longitudinal data starting before conception are scarce. Our aim was to determine the changes of the daily total sleep time (TST) and physical activity duration (PAD) from before conception to end of pregnancies in respect of pregestational maternal factors. METHODS This longitudinal observational study formed part of the CONIMPREG research project and recruited healthy women planning to become pregnant. Sleep and physical activity were recorded around-the-clock for ≥4 days via actigraphy before conception and during each trimester of pregnancy. Data were adjusted according to pregestational maternal body composition, parity and age. RESULTS Among 123 women with eligible data, the unadjusted mean (95% confidence interval) TST increased from 415.3 min (405.5-425.2 min) before conception to 458.0 min (445.4-470.6 min) in the 1st trimester, remaining high through the 2nd and 3rd trimesters. Variation was substantial before conception (±2SD range: 307-523 min). The unadjusted mean PAD before conception was 363.7 min (±2SD range: 120-608 min), decreasing sharply to 262.1 min in the first trimester and more gradually thereafter. Vigorous and moderate activity decreased more than light activity. TST and PAD were significantly associated with age, parity, and pregestational body fat percentage; lean body mass was negatively correlated with TST. Results were generally unaffected by seasonal variations. CONCLUSION Marked variations were found in pregestational TST and PAD. Healthy women slept ≥30 min longer during pregnancy, while PAD decreased by ≥ 90 min in early pregnancy and continued to decrease thereafter.
Collapse
Affiliation(s)
- Alexander Vietheer
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway; Department of Clinical Science, University of Bergen, Bergen, Norway.
| | - Torvid Kiserud
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway; Department of Clinical Science, University of Bergen, Bergen, Norway
| | - Rolv Terje Lie
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway; Department of Global Public Health and Primary Care, University of Bergen, Bergen, Norway; Norwegian Institute of Public Health, Bergen, Norway
| | | | - Jörg Kessler
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway; Department of Clinical Science, University of Bergen, Bergen, Norway
| |
Collapse
|
3
|
Pisanu S, Deledda A, Loviselli A, Huybrechts I, Velluzzi F. Validity of Accelerometers for the Evaluation of Energy Expenditure in Obese and Overweight Individuals: A Systematic Review. J Nutr Metab 2020; 2020:2327017. [PMID: 32832147 PMCID: PMC7424495 DOI: 10.1155/2020/2327017] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Accepted: 05/16/2020] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE Even though the validity of accelerometers for the measurement of energy expenditure (EE) has been demonstrated for normal-weight individuals, the applicability of this instrument in obese individuals remains controversial. This review aims to summarize the level of agreement between accelerometers and the gold standards (indirect calorimetry and doubly labelled water) for the measurement of energy expenditure (EE) in obese or overweight individuals. METHODS The literature search was limited to comparison studies assessing agreement in EE determination between accelerometers and indirect calorimetry (IC) or doubly labelled water (DLW). We searched in PubMed and in Scopus until March 1, 2019. The analysis was restricted to obese or overweight adult individuals. The following descriptive information was extracted for each study: sample size, characteristics of participants (sex, age, BMI, fat mass percentage, any pathological conditions, modality of recruitment in the study, and exclusion criteria), accelerometer description (model, type and body position), and type of gold standard and validity protocol (duration, conditions, and requirements during and before the experiment). Three review authors independently screened the obtained results, and the quality of the selected articles was assessed by the QUADAS-2 tool. RESULTS We obtained seventeen eligible articles, thirteen of which showed concerns for the applicability section, due to the patient selection. Regarding the accelerometers, nine devices were validated in the included studies with the BodyMedia SenseWear® (SWA) being the most frequently validated. Although correlations between accelerometers and the gold standard were high in some studies, agreement between the two methods was low, as shown by the Bland-Altman plots. CONCLUSIONS Most accelerometer estimations of EE were inaccurate for obese/overweight subjects, and authors advise to improve the accuracy of algorithms for SWA software, or the predicted equations for estimating EE from other accelerometers.
Collapse
Affiliation(s)
- Silvia Pisanu
- Department of Biomedical Sciences, University of Cagliari, Cagliari, Italy
| | - Andrea Deledda
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Andrea Loviselli
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Inge Huybrechts
- International Agency for Research on Cancer, Nutrition and Metabolism Section, Lyon, France
| | - Fernanda Velluzzi
- Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| |
Collapse
|
4
|
O’Driscoll R, Turicchi J, Hopkins M, Horgan GW, Finlayson G, Stubbs JR. Improving energy expenditure estimates from wearable devices: A machine learning approach. J Sports Sci 2020; 38:1496-1505. [DOI: 10.1080/02640414.2020.1746088] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Ruairi O’Driscoll
- Appetite Control and Energy Balance Group, School of Psychology, University of Leeds, Leeds, UK
| | - Jake Turicchi
- Appetite Control and Energy Balance Group, School of Psychology, University of Leeds, Leeds, UK
| | - Mark Hopkins
- School of Food Science and Nutrition, Faculty of Mathematics and Physical Sciences, University of Leeds, Leeds, UK
| | | | - Graham Finlayson
- Appetite Control and Energy Balance Group, School of Psychology, University of Leeds, Leeds, UK
| | - James. R. Stubbs
- Appetite Control and Energy Balance Group, School of Psychology, University of Leeds, Leeds, UK
| |
Collapse
|
5
|
O’Driscoll R, Turicchi J, Hopkins M, Gibbons C, Larsen SC, Palmeira AL, Heitmann BL, Horgan GW, Finlayson G, Stubbs RJ. The validity of two widely used commercial and research-grade activity monitors, during resting, household and activity behaviours. HEALTH AND TECHNOLOGY 2019. [DOI: 10.1007/s12553-019-00392-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
AbstractWearable devices are increasingly prevalent in research environments for the estimation of energy expenditure (EE) and heart rate (HR). The aim of this study was to validate the HR and EE estimates of the Fitbit charge 2 (FC2), and the EE estimates of the Sensewear armband mini (SWA). We recruited 59 healthy adults to participate in walking, running, cycling, sedentary and household tasks. Estimates of HR from the FC2 were compared to a HR chest strap (Polar) and EE to a stationary metabolic cart (Vyntus CPX). The SWA overestimated overall EE by 0.03 kcal/min−1 and was statistically equivalent to the criterion measure, with a mean absolute percentage error (MAPE) of 29%. In contrast, the FC2 was not equivalent overall (MAPE = 44%). In household tasks, MAPE values of 93% and 83% were observed for the FC2 and SWA, respectively. The FC2 HR estimates were equivalent to the criterion measure overall. The SWA is more accurate than the commercial-grade FC2. Neither device is consistently accurate across the range of activities used in this study. The HR data obtained from the FC2 is more accurate than its EE estimates and future research may focus more on this variable.
Collapse
|
6
|
Body composition in overweight and obese women postpartum: bioimpedance methods validated by dual energy X-ray absorptiometry and doubly labeled water. Eur J Clin Nutr 2016; 70:1181-1188. [PMID: 27026424 DOI: 10.1038/ejcn.2016.50] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 02/26/2016] [Accepted: 03/03/2016] [Indexed: 01/09/2023]
Abstract
BACKGROUND/OBJECTIVES Obesity, pregnancy and lactation all affect body composition. Simple methods to estimate body composition are useful in clinical practice and to evaluate interventions. In overweight and obese lactating women, such methods are not fully validated. The objective of this study was to validate the accuracy and precision of bioimpedance spectroscopy (BIS) by Xitron 4200 and 8-electrode multifrequency impedance (multifrequency bioimpedance analysis, MFBIA) by Tanita MC180MA with the reference methods dual energy X-ray absorptiometry (DXA) and doubly labeled water (DLW) for the assessment of body composition in 70 overweight and obese women postpartum. SUBJECTS/METHODS The LEVA-study (Lifestyle for Effective Weight loss during lactation) consisted of an intervention and follow-up with three assessments at 3, 6 and 15 months postpartum, which made possible the validation of both accuracy and precision. Mean differences between methods were tested by a paired t-test and Bland-Altman plots for systematic bias. RESULTS At baseline, BIS and MFBIA underestimated fat mass (FM) by 2.6±2.8 and 8.0±4.2 kg compared with DXA (P<0.001) but without systematic bias. BIS and MFBIA overestimated total body water (TBW) by 2.4±2.2 and 4.4±3.2 kg (P<0.001) compared with DLW, with slight systematic bias by BIS. BIS correctly estimated muscle mass without systematic bias (P>0.05). BIS overestimated changes in TBW (P=0.01) without systematic bias, whereas MFBIA varied greatly and with systematic bias. CONCLUSIONS BIS underestimates mean FM compared with DXA but can detect mean changes in body composition, although with large limits of agreement. BIS both accurately and precisely estimates muscle mass in overweight and obese women postpartum. MFBIA underestimates FM and overestimates TBW by proprietary equations compared with DXA and DLW.
Collapse
|
7
|
Rotella CM, Dicembrini I. Measurement of body composition as a surrogate evaluation of energy balance in obese patients. World J Methodol 2015; 5:1-9. [PMID: 25825693 PMCID: PMC4374088 DOI: 10.5662/wjm.v5.i1.1] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2013] [Revised: 02/18/2015] [Accepted: 03/16/2015] [Indexed: 02/06/2023] Open
Abstract
In clinical practice obesity is primarily diagnosed through the body mass index. In order to characterize patients affected by obesity the use of traditional anthropometric measures appears misleading. Beyond the body mass index, there are overwhelming evidences towards the relevance of a more detailed description of the individual phenotype by characterizing the main body components as free-fat mass, muscle mass, and fat mass. Among the numerous techniques actually available, bioelectrical impedance analysis seems to be the most suitable in a clinical setting because it is simple, inexpensive, noninvasive, and highly reproducible. To date, there is no consensus concerning the use of one preferred equation for the resting energy expenditure in overweight and/or obese population. Energy restriction alone is an effective strategy to achieve an early and significant weight loss, however it results in a reduction of both fat and lean mass therefore promoting or aggravating an unfavourable body composition (as sarcobesity) in terms of mortality and comorbidities. Therefore the implementation of daily levels of physical activity should be simultaneously promoted. The major role of muscle mass in the energy balance has been recently established by the rising prevalence of the combination of two condition as sarcopenia and obesity. Physical exercise stimulates energy expenditure, thereby directly improving energy balance, and also promotes adaptations such as fiber type, mitochondrial biogenesis, improvement of insulin resistance, and release of myokines, which may influence different tissues, including muscle.
Collapse
|
8
|
Inflammatory cytokines in general and central obesity and modulating effects of physical activity. PLoS One 2015; 10:e0121971. [PMID: 25781614 PMCID: PMC4363366 DOI: 10.1371/journal.pone.0121971] [Citation(s) in RCA: 285] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2014] [Accepted: 02/05/2015] [Indexed: 01/17/2023] Open
Abstract
Context Chronic systemic inflammation in obesity originates from local immune responses in visceral adipose tissue. However, assessment of a broad range of inflammation-mediating cytokines and their relationship to physical activity and adipometrics has scarcely been reported to date. Objective To characterize the profile of a broad range of pro- and anti-inflammatory cytokines and the impact of physical activity and energy expenditure in individuals with general obesity, central obesity, and non-obese subjects. Design, Setting, and Participants A cross-sectional study comprising 117 obese patients (body mass index (BMI) ≥ 30) and 83 non-obese community-based volunteers. Main Outcomes Measures Serum levels of interleukin (IL)-2, IL-4, IL-5, IL-10, IL-12, IL-13, granulocyte-macrophage colony-stimulating factor (GM-CSF), interferon (IFN)-γ and tumor necrosis factor (TNF)-α were measured. Physical activity and energy expenditure (MET) were assessed with actigraphy. Adipometrics comprised BMI, weight, abdominal-, waist- and hip-circumference, waist to hip ratio (WHR), and waist-to-height-ratio (WHtR). Results General obesity was associated with significantly elevated levels of IL-5, IL-10, IL-12, IL-13, IFN-γ and TNF-α, central obesity with significantly elevated IL-5, IL-10, IL-12, IL-13 and IFN-γ-levels. In participants with general obesity, levels of IL-4, IL-10 and IL-13 were significantly elevated in participants with low physical activity, even when controlled for BMI which was negatively associated with physical acitivity. Cytokines significantly correlated with adipometrics, particularly in obese participants. Conclusions Results confirm up-regulation of certain pro- and anti-inflammatory cytokines in obesity. In obese subjects, physical activity may lower levels and thus reduce pro-inflammatory effects of cytokines that may link obesity, insulin resistance and diabetes.
Collapse
|
9
|
Abstract
PURPOSE OF REVIEW Physical activity is the main determinant of variability of individual energy expenditure. Reliable assessment of the activity level of an individual provides information on energy requirement and vital health. Here, evidence is presented on the validity of methods to assess physical activity as applied in health and disease. RECENT FINDINGS Improvement of technology has resulted in a growing number of physical activity monitors to evaluate the activity level of an individual. Outcome measures vary from raw data on body acceleration and posture to activity levels derived from proprietary algorithms based on body acceleration combined with sensor information on additional activity-induced physiological responses. Data interpretation is limited by evidence-based studies on the value of measured parameters for the assessment of physical activity. SUMMARY The optimal tool for reliable assessment of physical activity is an accelerometer providing a valid measure of body movement. Overall validity is derived from studies using doubly labelled water-assessed activity-induced energy as a reference. Thus, out of the large range of activity monitors, three came out with a better validity. The ultimate tool is a single unobtrusive device allowing valid and long-term monitoring of activity with regard to type and intensity.
Collapse
Affiliation(s)
- Klaas R Westerterp
- Department of Human Biology, Maastricht University Medical Centre, Maastricht, The Netherlands
| |
Collapse
|
10
|
Hills AP, Mokhtar N, Byrne NM. Assessment of physical activity and energy expenditure: an overview of objective measures. Front Nutr 2014; 1:5. [PMID: 25988109 PMCID: PMC4428382 DOI: 10.3389/fnut.2014.00005] [Citation(s) in RCA: 290] [Impact Index Per Article: 26.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Accepted: 05/27/2014] [Indexed: 12/15/2022] Open
Abstract
The ability to assess energy expenditure (EE) and estimate physical activity (PA) in free-living individuals is extremely important in the global context of non-communicable diseases including malnutrition, overnutrition (obesity), and diabetes. It is also important to appreciate that PA and EE are different constructs with PA defined as any bodily movement that results in EE and accordingly, energy is expended as a result of PA. However, total energy expenditure, best assessed using the criterion doubly labeled water (DLW) technique, includes components in addition to physical activity energy expenditure, namely resting energy expenditure and the thermic effect of food. Given the large number of assessment techniques currently used to estimate PA in humans, it is imperative to understand the relative merits of each. The goal of this review is to provide information on the utility and limitations of a range of objective measures of PA and their relationship with EE. The measures discussed include those based on EE or oxygen uptake including DLW, activity energy expenditure, physical activity level, and metabolic equivalent; those based on heart rate monitoring and motion sensors; and because of their widespread use, selected subjective measures.
Collapse
Affiliation(s)
- Andrew P Hills
- Centre for Nutrition and Exercise, Mater Research Institute, University of Queensland , South Brisbane, QLD , Australia ; Griffith Health Institute, Griffith University , Gold Coast, QLD , Australia
| | - Najat Mokhtar
- Nutritional and Health-Related Environmental Studies Section, International Atomic Energy Agency , Vienna , Austria
| | - Nuala M Byrne
- Faculty of Health Sciences and Medicine, Bond University , Gold Coast, QLD , Australia
| |
Collapse
|