1
|
Ouidir M, Tekola-Ayele F, Canty T, Grantz KL, Sciscione A, Tong D, Jones RR, Sundaram R, Williams A, Stevens D, Mendola P. Acute ambient air pollution exposure and placental Doppler results in the NICHD fetal growth studies - Singleton cohort. ENVIRONMENTAL RESEARCH 2021; 202:111728. [PMID: 34297937 PMCID: PMC8578287 DOI: 10.1016/j.envres.2021.111728] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 06/21/2021] [Accepted: 07/16/2021] [Indexed: 05/29/2023]
Abstract
BACKGROUND Increased placental vascular resistance is a proposed mechanism by which air pollution exposure during pregnancy lowers birth weight and increases pregnancy-induced hypertensive disorders. OBJECTIVE To examine the impact of acute air pollution exposure during pregnancy on uterine and umbilical artery Doppler indicators of placental vascular resistance. METHODS After a first ultrasound to confirm gestational age, 2562 pregnant women recruited in 12 clinics throughout the United States underwent up to five standardized ultrasounds with Doppler measurements. Exposures to 11 air pollutants were estimated for the hour of ultrasound and each of the 2 h prior to ultrasound at the clinics using the National Air Quality Forecast Capability reanalysis products. We used mixed logistic regression to study the longitudinal odds ratio (OR) of any, uni- or bi-lateral systolic and diastolic uterine artery notching compared to no notching and the longitudinal OR of abnormal end diastolic flow of the umbilical artery compared to forward flow. Uterine and umbilical artery resistance indexes were studied using linear mixed models. RESULTS Each inter-quartile range (IQR) increase of particulate matter < 2.5 μm, nitrate, ammonium, primary organic matter (POM) and nitrogen dioxide during the hour of ultrasound was associated with a decreased risk of unilateral systolic notch and with increased resistance index of the left uterine artery. For the umbilical artery, each IQR increase in ozone was associated with decreased resistance index (b: -0.26, 95 % CI: -0.52, -0.01) and with a decreased risk of abnormal end diastolic flow (OR: 0.36, 95 % CI: 0.14, 0.94); while each IQR increase of elemental carbon and POM was associated with increased risk of abnormal end diastolic flow (OR: 1.47, 95 % CI: 1.02, 2.13 and OR: 1.67, 95 % CI: 1.17, 2.39, respectively). DISCUSSION Our results suggest acute air pollution exposure may influence placental vascular resistance.
Collapse
Affiliation(s)
- Marion Ouidir
- Epidemiology Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA
| | - Fasil Tekola-Ayele
- Epidemiology Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA
| | - Timothy Canty
- Department of Atmospheric and Oceanic Science, University of Maryland, College Park, MD, USA
| | - Katherine L Grantz
- Epidemiology Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA
| | - Anthony Sciscione
- Department of Obstetrics and Gynecology, Christiana Care Health System, Newark, DE, USA
| | - Daniel Tong
- Center for Spatial Science and Systems, George Mason University, Fairfax, VA, USA
| | - Rena R Jones
- Occupational and Environmental Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Rockville, MD, USA
| | - Rajeshwari Sundaram
- Biostatistics and Bioinformatics Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA
| | - Andrew Williams
- University of North Dakota, School of Medicine & Health Sciences, Grand Forks, ND, USA
| | - Danielle Stevens
- Epidemiology Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA
| | - Pauline Mendola
- Epidemiology Branch, Division of Intramural Population Health Research, Eunice Kennedy Shriver National Institute of Child Health and Human Development, Bethesda, MD, USA; Department of Epidemiology and Environmental Health, School of Public Health and Health Professions, University at Buffalo, Buffalo, NY, USA.
| |
Collapse
|
2
|
Park IY, Wie JH, Park JH, Kwon JY. Combination of three-dimensional placental vascular indices and volume and uterine artery pulsatility index at 10-13 weeks of gestation could improve the prediction of adverse pregnancy outcomes. J Obstet Gynaecol Res 2021; 47:2051-2058. [PMID: 33821516 DOI: 10.1111/jog.14781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 02/19/2021] [Accepted: 03/20/2021] [Indexed: 11/28/2022]
Abstract
AIM To evaluate whether three-dimensional (3D) placental vascular indices and volumes during the first trimester of pregnancy can be used as predictors of subsequent adverse outcomes. METHODS This was a prospective cohort study including women with singleton pregnancies between 10 and 13 weeks. 3D placental volume and vascular indices and uterine artery pulsatility index (UtA-PI) were measured. Adverse outcomes were defined whether there was any of the following complications: small for gestational age pregnancy, preterm delivery, and preeclampsia. The serum pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (β-hCG) levels were also compared. We analyzed the screening performances of these parameters for prediction of any of adverse outcomes. RESULTS Of 348 women screened, 300 women were completed follow-up. Overall, 57 (19.0%) of 300 women developed any of adverse pregnancy outcomes. Multiple logistic regression analysis demonstrated that gestational age-adjusted z-scores of log10 placental volume (odds ratio [OR], 0.572; 95% confidence interval [CI], 0.416-0.788), log10 placental vascularization flow index (VFI; OR, 0.676; 95% CI, 0.496-0.921), and log10 UtA-PI (OR, 1.910; 95% CI, 1.335-2.731) were significantly associated adverse pregnancy outcomes. The multivariate model combining placental VFI, placental volume, UtA-PI, and underweight or obese body mass index exhibited the highest screening performances (AUC = 0.77) and PAPP-A and β-hCG did not add any significance to multivariate model. CONCLUSIONS Placental volume and vascular indices at 10-13 weeks of gestation are significantly associated with adverse pregnancy outcomes. Combination of these placental indices and UtA-PI could improve the screening performance for adverse outcomes.
Collapse
Affiliation(s)
- In Yang Park
- Department of Obstetrics and Gynecology, The Catholic University of Korea, Seoul, South Korea
| | - Jeong Ha Wie
- Department of Obstetrics and Gynecology, The Catholic University of Korea, Seoul, South Korea
| | - Ji Hyun Park
- Department of Obstetrics and Gynecology, The Catholic University of Korea, Seoul, South Korea
| | - Ji Young Kwon
- Department of Obstetrics and Gynecology, The Catholic University of Korea, Seoul, South Korea
| |
Collapse
|
3
|
Hanchard TJ, de Vries BS, Quinton AE, Sinosich M, Hyett JA. Combining early (<11 weeks' gestation) ultrasound features and maternal factors to predict small-for-gestational age neonates. Australas J Ultrasound Med 2020; 24:37-47. [PMID: 34760610 DOI: 10.1002/ajum.12224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Objectives Placental related adverse pregnancy outcomes such as fetal growth restriction have significant short- and long-term implications for both mother and fetus. This study aimed to determine if conventional and novel early first trimester ultrasound measures are associated with small for gestational age (SGA) neonates. In addition, we aimed to assess whether a combination of ultrasound measures, maternal characteristics and biochemistry improved the prediction of this adverse pregnancy outcome. Methods This was a prospective cohort study including ultrasound measurements: trophoblast thickness (TT), trophoblast volume (TV), mean uterine artery pulsatility index, crown-rump length, fetal heart rate, mean sac diameter (MSD) and yolk sac diameter. Biochemical markers considered in the analysis were placental growth factor (PIGF), pregnancy - associated plasma protein A (PAPP-A), beta human chorionic gonadotropin and alpha fetoprotein. Regression models were fitted for ultrasound parameters using multiples of the median (MoM). All measures were compared with normal birthweight (BW) ≥10th centile and SGA (BW < 10th centile). Logistic regression analysis was used to create a clinical prediction model for SGA based on maternal characteristics, ultrasound measurements at <11 weeks gestational age and maternal biochemistry collected at 10-14 weeks. Results As compared to pregnancies delivered of babies with normal BW (n = 1068), MoM values for TT, TV, MSD, PAPP-A and PIGF were significantly reduced (P < 0.05) in pregnancies delivered of SGA babies (n = 73). The proposed logistic regression model includes maternal height, TV and PIGF resulting in an area under the receiver operator curve 0.70 (95% CI 0.63-0.76) for the prediction of SGA. Conclusion A significantly decreased TV, measured <11 weeks gestation, is predictive of BW < 10th centile. With addition of maternal height and PIGF, this three-marker algorithm provided a reasonable predictive value for the development of SGA later in pregnancy.
Collapse
Affiliation(s)
- Tracey J Hanchard
- South Coast Ultrasound for Women Wollongong New South Wales Australia.,Discipline of Obstetrics, Gynaecology and Neonatology Central Clinical School Faculty of Medicine University of Sydney Sydney New South Wales Australia
| | - Bradley S de Vries
- Discipline of Obstetrics, Gynaecology and Neonatology Central Clinical School Faculty of Medicine University of Sydney Sydney New South Wales Australia.,RPA Women and Babies Royal Prince Alfred Hospital Camperdown New South Wales Australia
| | - Ann E Quinton
- Discipline of Obstetrics, Gynaecology and Neonatology Central Clinical School Faculty of Medicine University of Sydney Sydney New South Wales Australia.,School of Health, Medical and Applied Science Central Queensland University Sydney New South Wales Australia
| | - Michael Sinosich
- Prenatal Testing DHM Pathology Sonic Healthcare Macquarie Park New South Wales Australia
| | - Jonathan A Hyett
- Discipline of Obstetrics, Gynaecology and Neonatology Central Clinical School Faculty of Medicine University of Sydney Sydney New South Wales Australia.,RPA Women and Babies Royal Prince Alfred Hospital Camperdown New South Wales Australia
| |
Collapse
|
4
|
Hanchard TJ, de Vries BS, Quinton AE, Sinosich M, Hyett JA. Ultrasound features prior to 11 weeks' gestation and first-trimester maternal factors in prediction of hypertensive disorders of pregnancy. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:629-636. [PMID: 31909523 DOI: 10.1002/uog.21962] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Revised: 12/25/2019] [Accepted: 12/31/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES Maternal hypertensive disorders (MHD), including pregnancy-induced hypertension and pre-eclampsia, are estimated to occur in 7-10% of pregnancies worldwide and have significant short- and long-term implications for both mother and fetus. This study aimed to determine the association of conventional and novel early first-trimester ultrasound measures with MHD and whether these ultrasound measures, combined with maternal characteristics and biochemistry, improve the prediction of MHD. METHODS This was a prospective cohort study of consecutive women with a singleton pregnancy, attending for an early (5 + 1 to 11 + 0 weeks' gestation) ultrasound examination at a private obstetric ultrasound practice between February 2016 and August 2018. Recorded ultrasound measurements included mean sac diameter, yolk sac diameter, crown-rump length, fetal heart rate (FHR), trophoblast thickness, trophoblast volume (TV) and mean uterine artery pulsatility index. Maternal biochemistry was assessed at 10-14 weeks and included beta-human chorionic gonadotropin, pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PlGF) and maternal serum alpha-fetoprotein. Regression models were fitted for each ultrasound parameter and multiples of the median (MoM) were calculated. All measures were compared between women who had a normotensive outcome and those who subsequently developed MHD. Logistic regression analysis was used to create a prediction model for MHD based on maternal characteristics, ultrasound measurements at 5 + 1 to 11 + 0 weeks' gestation and maternal biochemistry at 10-14 weeks. RESULTS In total, 1141 women were included in the analysis, of whom 1086 (95.2%) were normotensive at delivery and 55 (4.8%) developed MHD. Women who developed MHD weighed significantly more than did normotensive women (P < 0.0001). Mean MoM values for TV (P = 0.006), PAPP-A (P = 0.031) and PlGF (P = 0.044) were decreased significantly in pregnancies that subsequently developed MHD. The proposed logistic regression model includes maternal weight and height and MoM values for TV, FHR and PlGF, resulting in an area under the receiver-operating-characteristics curve of 0.80 (95% CI, 0.75-0.86). CONCLUSION The combination of maternal weight and height, TV and FHR, measured prior to 11 weeks' gestation, and first-trimester PlGF appears to have good predictive value for development of MHD later in pregnancy. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- T J Hanchard
- South Coast Ultrasound for Women, Wollongong, NSW, Australia
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, NSW, Australia
| | - B S de Vries
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, NSW, Australia
- RPA Women and Babies, Royal Prince Alfred Hospital, Camperdown, NSW, Australia
| | - A E Quinton
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, NSW, Australia
- School of Health, Medical and Applied Science, Central Queensland University, Sydney, NSW, Australia
| | - M Sinosich
- Prenatal Testing DHM Pathology, Sonic Healthcare, Macquarie Park, NSW, Australia
| | - J A Hyett
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, NSW, Australia
- RPA Women and Babies, Royal Prince Alfred Hospital, Camperdown, NSW, Australia
| |
Collapse
|
5
|
Taylor TJ, Quinton AE, de Vries BS, Hyett JA. First-trimester ultrasound features associated with subsequent miscarriage: A prospective study. Aust N Z J Obstet Gynaecol 2019; 59:641-648. [PMID: 30724337 DOI: 10.1111/ajo.12944] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Accepted: 12/11/2018] [Indexed: 11/29/2022]
Abstract
BACKGROUND First-trimester miscarriage is common, with women increasingly offered an ultrasound scan early in the first trimester to assess the status of their pregnancy. Ultrasound is uniquely situated to significantly impact the clinical management of these women. AIMS This study aims to determine whether there were any differences in the early ultrasound appearances of pregnancies that continued to be viable or resulted in miscarriage before 12 weeks gestation. MATERIALS AND METHODS This was a prospective cohort study including ultrasound measurements: mean sac diameter (MSD), yolk sac diameter (YSD), crown-rump length (CRL), fetal heart rate (FHR), trophoblast thickness, trophoblast volume (TTV) and mean uterine artery pulsatility index (meanUAPI). Regression models were fitted for each parameter and Z-scores compared between cohorts that progressed or miscarried after the scan but before 12 weeks gestation. Logistic regression analysis was used to create a prediction model for miscarriage prior to 12 weeks gestation based on the standardised ultrasound measurements recorded during the early first-trimester scan. RESULTS Comparison of Z-Scores for meanUAPI, TTV, FHR and MSD demonstrated significant variation between the two groups. The proposed logistic regression model resulted in an area under the receiver operator curve of 0.81. At a false-positive rate of 30%, the model resulted in a sensitivity of 76% (95% CI 64-89%). CONCLUSION The combination of FHR, meanUAPI, TTV in a prediction model for miscarriage may prove to be of value for ongoing pregnancy management in the first trimester.
Collapse
Affiliation(s)
- Tracey J Taylor
- South Coast Ultrasound for Women, Wollongong, New South Wales, Australia.,Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia
| | - Ann E Quinton
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia.,School of Health, Medical and Applied Science, Central Queensland University, Sydney, New South Wales, Australia
| | - Bradley S de Vries
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia.,RPA Women and Babies, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| | - Jonathon A Hyett
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, Faculty of Medicine, University of Sydney, Sydney, New South Wales, Australia.,RPA Women and Babies, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia
| |
Collapse
|
6
|
Sotiriadis A, Hernandez-Andrade E, da Silva Costa F, Ghi T, Glanc P, Khalil A, Martins WP, Odibo AO, Papageorghiou AT, Salomon LJ, Thilaganathan B. ISUOG Practice Guidelines: role of ultrasound in screening for and follow-up of pre-eclampsia. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2019; 53:7-22. [PMID: 30320479 DOI: 10.1002/uog.20105] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 07/15/2018] [Accepted: 07/22/2018] [Indexed: 06/08/2023]
Affiliation(s)
- A Sotiriadis
- Second Department of Obstetrics and Gynecology, Faculty of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - E Hernandez-Andrade
- Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, Hutzel Women Hospital, Wayne State University, Detroit, MI, USA
| | - F da Silva Costa
- Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil; and Department of Obstetrics and Gynaecology, Monash University, Melbourne, Australia
| | - T Ghi
- Obstetrics and Gynecology Unit, University of Parma, Parma, Italy
| | - P Glanc
- Department of Radiology, University of Toronto, Toronto, Ontario, Canada
| | - A Khalil
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK; and Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
| | - W P Martins
- SEMEAR Fertilidade, Reproductive Medicine and Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil
| | - A O Odibo
- Department of Obstetrics and Gynecology, Morsani College of Medicine, University of South Florida, Tampa, FL, USA
| | - A T Papageorghiou
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK; and Nuffield Department of Obstetrics and Gynecology, University of Oxford, Women's Center, John Radcliffe Hospital, Oxford, UK
| | - L J Salomon
- Department of Obstetrics and Fetal Medicine, Hopital Necker-Enfants Malades, Assistance Publique-Hopitaux de Paris, Paris Descartes University, Paris, France
| | - B Thilaganathan
- Fetal Medicine Unit, St George's University Hospitals NHS Foundation Trust, London, UK; and Vascular Biology Research Centre, Molecular and Clinical Sciences Research Institute, St George's University of London, London, UK
| |
Collapse
|
7
|
Soongsatitanon A, Phupong V. First trimester 3D ultrasound placental volume for predicting preeclampsia and/or intrauterine growth restriction. J OBSTET GYNAECOL 2018; 39:474-479. [PMID: 30585097 DOI: 10.1080/01443615.2018.1529152] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The objective of the study was to determine the sensitivity of the placental volume for predicting preeclampsia and/or intrauterine growth restriction (IUGR) in the first trimester. A prospective observational study was conducted in pregnant women with a gestational age of 11 to 13+6 weeks. A 3 D transabdominal placental volume measurement was performed at the time of first-trimester aneuploidy screening. The predictive values of this test were calculated. The data from 360 pregnant women was analysed. Seventeen cases developed preeclampsia and/or IUGR. The 10th percentile of placental volume was used as the cut-off level. The sensitivity, specificity, positive predictive value and negative predictive value of placental volume less than the 10th percentile for prediction of preeclampsia and/or IUGR were 23.5%, 90.7%, 11.1% and 96%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value for prediction of early onset preeclampsia were 50%, 90.7%, 3.0% and 99.7%, respectively. This study demonstrated that the placental volume was lower in the cases with preeclampsia and/or IUGR. It was not an effective screening tool for preeclampsia and/or IUGR in the first trimester. IMPACT STATEMENT What is already known on this subject? Placental volume may reflect trophoblast invasion, but much earlier, in the first trimester. The estimation of a smaller early placental volume has been shown to be significantly associated with preeclampsia and IUGR. What do the results of this study add? The placental volume was lower in the cases with preeclampsia and/or IUGR. It was not an effective screening tool for preeclampsia and/or IUGR in the first trimester. But it might be used for predicting early onset preeclampsia. What are the implications of these findings for clinical practice and/or further research? Further research of placental volume in the first trimester for predicting an early onset preeclampsia should be conducted.
Collapse
Affiliation(s)
- Adjima Soongsatitanon
- a Placental Related Diseases Research Unit and the Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Faculty of Medicine , Chulalongkorn University , Bangkok , Thailand
| | - Vorapong Phupong
- a Placental Related Diseases Research Unit and the Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Faculty of Medicine , Chulalongkorn University , Bangkok , Thailand
| |
Collapse
|
8
|
Efficiency of placental three dimentional power Doppler ultrasonography for predicting preeclampsia in early pregnancy. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2018. [DOI: 10.1016/j.ejrnm.2017.11.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
9
|
Leijnse JEW, de Heus R, de Jager W, Rodenburg W, Peeters LLH, Franx A, Eijkelkamp N. First trimester placental vascularization and angiogenetic factors are associated with adverse pregnancy outcome. Pregnancy Hypertens 2018; 13:87-94. [PMID: 30177079 DOI: 10.1016/j.preghy.2018.04.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 02/11/2018] [Accepted: 04/11/2018] [Indexed: 11/29/2022]
Abstract
BACKGROUND Hypertensive disorders, fetal growth restriction and preterm birth are major obstetrical complications and are related to impaired placentation. Early identification of impaired placentation can advance clinical care by preventing or postpone adverse pregnancy outcome. OBJECTIVES Determine whether sonographic assessed placental vascular development and concomitant changes in inflammation- and/or angiogenesis-related serumproteins differ in the first trimester between uncomplicated pregnancies and pregnancies with adverse outcome. STUDY DESIGN This prospective longitudinal study defines adverse pregnancy outcome as conditions associated with impaired placentation; fetal growth restriction, hypertensive disorder, preterm birth and placental abruption. The vascularization index, flow index, vascularization flow index and placental volume were determined at 8, 10 and 12 weeks pregnancy from 64 women using 3D power Doppler. Serum levels were analyzed for Angiopoetin-1 and -2, Leptin, VEGF-R, VEGF, and EGF. RESULTS The vascularization index and vascular flow index increased in uneventful pregnancies with almost 50% between 8 and 12 weeks, resulting in a ∼50% higher vascularization index at 12 weeks compared to women with an adverse pregnancy outcome. Women with an adverse pregnancy outcome (n = 13) had significantly lower indices and placental volumes at all time points measured and these indices did not increase between 8 and 12 weeks. Reduced vascular development was associated with increased Angiopoietin-1 levels at 8 and 12 weeks and increased Leptin levels at 8 weeks. CONCLUSIONS Pregnancies with an adverse outcome caused by conditions associated with impaired placentation differ from uneventful pregnancies in having reduced placental vascularization accompanied by elevated circulating levels of Angiopoietin-1 and Leptin already in the first trimester.
Collapse
Affiliation(s)
- Johanna E W Leijnse
- Department of Obstetrics, Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3508 GA Utrecht, The Netherlands.
| | - Roel de Heus
- Department of Obstetrics, Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3508 GA Utrecht, The Netherlands
| | - Wilco de Jager
- Department of Pediatric Immunology, Laboratory of Translational Immunology and Multiplex Core Facility, Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3584 CX Utrecht, The Netherlands
| | - Wendy Rodenburg
- National Institute for Public Health and Environment (RIVM), 3721 MA Bilthoven, The Netherlands
| | - Louis L H Peeters
- Department of Obstetrics, Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3508 GA Utrecht, The Netherlands
| | - Arie Franx
- Department of Obstetrics, Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3508 GA Utrecht, The Netherlands
| | - Niels Eijkelkamp
- Laboratory of Neuroimmunology and Developmental Origins of Disease (NIDOD), Wilhelmina Children's Hospital, University Medical Centre Utrecht, 3584 EA Utrecht, The Netherlands
| |
Collapse
|
10
|
González-González NL, González Dávila E, Padrón E, Armas Gonzalez M, Plasencia W. Value of Placental Volume and Vascular Flow Indices as Predictors of Early and Late Preeclampsia at First Trimester. Fetal Diagn Ther 2018; 44:256-263. [PMID: 29393218 DOI: 10.1159/000481433] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2017] [Accepted: 08/07/2017] [Indexed: 12/28/2022]
Abstract
INTRODUCTION We evaluated the utility of placental volume and three-dimensional (3D) vascular flow indices to predict early and late preeclampsia. MATERIAL AND METHODS In 1,004 pregnancies attending routine care, we recorded first-trimester screening program for aneuploidy (FTSA) parameter and measured uterine artery pulsatility index (uterine-a PI). Placental volume and vascular flow indices were obtained using 3D power Doppler and VOCAL techniques. RESULTS Placental volume was lower and uterine-a PI was higher in both early and late preeclampsia groups versus nonaffected pregnancies. The prediction rate of placental volume in late preeclampsia was higher than that of uterine-a PI (AUROC 0.707 vs. 0.581, p < 0.011). The inclusion of placental volume improved significantly the prediction rate of total and late preeclampsia in the models constructed with maternal characteristics, FTSA, and uterine-a PI (AUROC 0.745 vs. 0.818, p < 0.004, and 0.740 vs. 0.812, p < 0.012, respectively). The inclusion of vascular indices did not improve the predictive value of these models. DISCUSSION Placental volume was an independent predictor of total, early, and late preeclampsia and its inclusion in combined predictive models significantly improved prediction rates. Reduced placental volume observed at first trimester in women with early and late preeclampsia suggests that these entities are the clinical expression of a similar pathophysiological process.
Collapse
Affiliation(s)
- Nieves L González-González
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, La Laguna,
| | - Enrique González Dávila
- Departamento de Matemáticas, Estadística e Investigación Operativa, Universidad de La Laguna, La Laguna, Spain
| | - Erika Padrón
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, La Laguna, Spain
| | - Marina Armas Gonzalez
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, La Laguna, Spain
| | | |
Collapse
|
11
|
Value of placental volume and vascular flow indices as predictors of intrauterine growth retardation. Eur J Obstet Gynecol Reprod Biol 2017; 212:13-19. [DOI: 10.1016/j.ejogrb.2017.03.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 02/22/2017] [Accepted: 03/03/2017] [Indexed: 11/23/2022]
|
12
|
Surányi A, Altorjay Á, Kaiser L, Nyári T, Németh G. Evaluation of placental vascularization by three-dimensional ultrasound examination in second and third trimester of pregnancies complicated by chronic hypertension, gestational hypertension or pre-eclampsia. Pregnancy Hypertens 2017; 8:51-59. [DOI: 10.1016/j.preghy.2017.03.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 01/27/2017] [Accepted: 03/17/2017] [Indexed: 10/19/2022]
|
13
|
Hettfleisch K, Bernardes LS, Carvalho MA, Pastro LDM, Vieira SE, Saldiva SRDM, Saldiva P, Francisco RPV. Short-Term Exposure to Urban Air Pollution and Influences on Placental Vascularization Indexes. ENVIRONMENTAL HEALTH PERSPECTIVES 2017; 125:753-759. [PMID: 27384326 PMCID: PMC5381983 DOI: 10.1289/ehp300] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 05/26/2016] [Accepted: 06/14/2016] [Indexed: 05/05/2023]
Abstract
BACKGROUND It has been widely demonstrated that air pollution can affect human health and that certain pollutant gases lead to adverse obstetric outcomes, such as preeclampsia and fetal growth restriction. OBJECTIVES We evaluated the influence of individual maternal exposure to air pollution on placental volume and vascularization evaluated in the first trimester of pregnancy. METHODS This was a cross-sectional study on low-risk pregnant women living in São Paulo, Brazil. The women carried passive personal NO2 and O3 monitors in the week preceding evaluation. We employed the virtual organ computer-aided analysis (VOCAL) technique using three-dimensional power Doppler ultrasound to evaluate placental volume and placental vascular indexes [vascularization index (VI), flow index (FI), and vascularization flow index (VFI)]. We analyzed the influence of pollutant levels on log-transformed placental vascularization and volume using multiple regression models. RESULTS We evaluated 229 patients. Increased NO2 levels had a significant negative association with log of VI (p = 0.020 and beta = -0.153) and VFI (p = 0.024 and beta = -0.151). NO2 and O3 had no influence on the log of placental volume or FI. CONCLUSIONS NO2, an estimator of primary air pollutants, was significantly associated with diminished VI and VFI in the first trimester of pregnancy.
Collapse
Affiliation(s)
| | - Lisandra Stein Bernardes
- Department of Obstetrics and Gynecology, and
- Address correspondence to L.S. Bernardes, The Procriar Study Group, Department of Obstetrics and Gynecology, School of Medicine at the University of São Paulo, São Paulo, Brazil; 255, Av. Dr. Enéas de Carvalho Aguiar, São Paulo, Brazil 05403-900. Telephone: 551126616209. E-mail:
| | - Mariana Azevedo Carvalho
- Department of Obstetrics and Gynecology, and
- Address correspondence to L.S. Bernardes, The Procriar Study Group, Department of Obstetrics and Gynecology, School of Medicine at the University of São Paulo, São Paulo, Brazil; 255, Av. Dr. Enéas de Carvalho Aguiar, São Paulo, Brazil 05403-900. Telephone: 551126616209. E-mail:
| | | | | | | | - Paulo Saldiva
- Institute of Advanced Studies of the University of São Paulo, São Paulo, Brazil
| | | |
Collapse
|
14
|
Evaluation of the predictive value of placental vascularisation indices derived from 3-Dimensional power Doppler whole placental volume scanning for prediction of pre-eclampsia: A systematic review and meta-analysis. Placenta 2017; 51:89-97. [DOI: 10.1016/j.placenta.2017.01.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 12/13/2016] [Accepted: 01/04/2017] [Indexed: 12/18/2022]
|
15
|
Milnerowicz-Nabzdyk E, Bizoń A, Zimmer M. How Does Tobacco Smoke Affect Fetal Growth Potential in the First Trimester of Pregnancy as Measured by Volume Parameters of the Fetus, Trophoblast, and Gestational Sac? Reprod Sci 2016; 24:548-559. [DOI: 10.1177/1933719116660845] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Ewa Milnerowicz-Nabzdyk
- 2nd Department and Clinic of Obstetrics and Gynaecology, Wroclaw Medical University, Wrocław, Poland
| | - Anna Bizoń
- Department of Biomedical and Environmental Analysis, Wroclaw Medical University, Wrocław, Poland
| | - Mariusz Zimmer
- 2nd Department and Clinic of Obstetrics and Gynaecology, Wroclaw Medical University, Wrocław, Poland
| |
Collapse
|
16
|
Wotherspoon AC, Young IS, McCance DR, Holmes VA. Evaluation of biomarkers for the prediction of pre-eclampsia in women with type 1 diabetes mellitus: A systematic review. J Diabetes Complications 2016; 30:958-66. [PMID: 26900097 DOI: 10.1016/j.jdiacomp.2016.02.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2015] [Revised: 01/19/2016] [Accepted: 02/01/2016] [Indexed: 12/17/2022]
Abstract
BACKGROUND Pre-eclampsia is a leading cause of maternal and perinatal morbidity and mortality. Women with type 1 diabetes are considered a high-risk group for developing pre-eclampsia. Much research has focused on biomarkers as a means of screening for pre-eclampsia in the general maternal population; however, there is a lack of evidence for women with type 1 diabetes. OBJECTIVES To undertake a systematic review to identify potential biomarkers for the prediction of pre-eclampsia in women with type 1 diabetes. SEARCH STRATEGY We searched Medline, EMBASE, Maternity and Infant Care, Scopus, Web of Science and CINAHL SELECTION CRITERIA: Studies were included if they measured biomarkers in blood or urine of women who developed pre-eclampsia and had pre-gestational type 1 diabetes mellitus Data collection and analysis A narrative synthesis was adopted as a meta-analysis could not be performed, due to high study heterogeneity. MAIN RESULTS A total of 72 records were screened, with 21 eligible studies being included in the review. A wide range of biomarkers was investigated and study size varied from 34 to 1258 participants. No single biomarker appeared to be effective in predicting pre-eclampsia; however, glycaemic control was associated with an increased risk while a combination of angiogenic and anti-angiogenic factors seemed to be potentially useful. CONCLUSIONS Limited evidence suggests that combinations of biomarkers may be more effective in predicting pre-eclampsia than single biomarkers. Further research is needed to verify the predictive potential of biomarkers that have been measured in the general maternal population, as many studies exclude women with diabetes preceding pregnancy.
Collapse
Affiliation(s)
- Amy C Wotherspoon
- Centre for Public Health, School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK
| | - Ian S Young
- Centre for Public Health, School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK
| | - David R McCance
- Regional Centre for Endocrinology and Diabetes, Royal Victoria Hospital, UK
| | - Valerie A Holmes
- Centre for Public Health, School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.
| |
Collapse
|
17
|
Fanget C, Chauleur C, Stadler A, Presles E, Varlet MN, Gris JC, Raia-Barjat T. Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study. PLoS One 2016; 11:e0156593. [PMID: 27294274 PMCID: PMC4905670 DOI: 10.1371/journal.pone.0156593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Accepted: 05/17/2016] [Indexed: 11/24/2022] Open
Abstract
Introduction The aim of this study was to correlate placental volumes deduced from three-dimensional ultrasound and virtual organ computer-aided analysis (VOCAL) software with systemic concentrations of D-dimer and soluble endothelial protein C receptor (sEPCR). Methods This was a monocentric experimental prospective study conducted from October 2008 to July 2009. Forty consecutive patients at risk of placental vascular pathology (PVP) recurrence or occurrence were included. Placental volumes were systematically measured three times (11–14, 16–18 and 20–22 weeks of gestation (WG)) by two independent sonographers. D-dimers and sEPCR plasma concentrations were measured using ELISA kits (Enzyme Linked ImmunoSorbent Assay). Results Eleven patients had a PVP. The plasma D-dimer level was positively correlated with placental volume (r = 0.45, p < 0.001). A smaller placental volume and placental quotient was evidenced in women who developed a PVP at the three gestational ages, and the difference was more pronounced during the third exam (20 WG). No obvious correlation could be demonstrated between the development of a PVP and the levels of D-dimer and sEPCR. There was no significant difference in the values of placental volumes measured by the two sonographers. Conclusion The placenta growth could be a major determinant of the elevation of D-dimer during pregnancy. Consideration of placental volume could allow for modulation of the D-dimer concentrations for restoring their clinical interest.
Collapse
Affiliation(s)
- Cécile Fanget
- Department of Gynecology and Obstetrics, University Hospital, Saint Etienne, France
| | - Céline Chauleur
- Department of Gynecology and Obstetrics, University Hospital, Saint Etienne, France
- Research Unit EA3065, Saint Etienne University Jean Monnet F 42023, Saint Etienne, France
| | - Amandine Stadler
- Department of Gynecology and Obstetrics, University Hospital, Saint Etienne, France
| | - Emilie Presles
- Research Unit EA3065, Saint Etienne University Jean Monnet F 42023, Saint Etienne, France
| | - Marie-Noëlle Varlet
- Department of Gynecology and Obstetrics, University Hospital, Saint Etienne, France
| | - Jean-Christophe Gris
- Laboratory of Haematology, University Hospital, Nîmes, France
- Research Unit EA2992, Montpellier University, Montpellier, France
| | - Tiphaine Raia-Barjat
- Department of Gynecology and Obstetrics, University Hospital, Saint Etienne, France
- Research Unit EA3065, Saint Etienne University Jean Monnet F 42023, Saint Etienne, France
- * E-mail:
| |
Collapse
|
18
|
Third trimester placental volume and biometry measurement: A method-development study. Placenta 2016; 42:51-8. [DOI: 10.1016/j.placenta.2016.04.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2015] [Revised: 03/14/2016] [Accepted: 04/07/2016] [Indexed: 11/22/2022]
|
19
|
Duan J, Chabot-Lecoanet AC, Perdriolle-Galet E, Christov C, Hossu G, Cherifi A, Morel O. Utero-placental vascularisation in normal and preeclamptic and intra-uterine growth restriction pregnancies: third trimester quantification using 3D power Doppler with comparison to placental vascular morphology (EVUPA): a prospective controlled study. BMJ Open 2016; 6:e009909. [PMID: 27033959 PMCID: PMC4823389 DOI: 10.1136/bmjopen-2015-009909] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
INTRODUCTION Preeclampsia (PE) and intra-uterine growth restriction (IUGR) are two major pregnancy complications related to chronic utero-placental hypoperfusion. Three-dimensional power Doppler (3DPD) angiography has been used for the evaluation of utero-placental vascularisation and three vascular indices have been calculated: the vascularisation index (VI), flow index (FI) and vascularisation-FI (VFI). However, several technical endpoints hinder the clinical use of 3DPD as physical characteristics and machine settings may affect 3DPD indices, and so its clinical significance is not yet clear. OBJECTIVES The primary objective is to better understand the clinical significance of 3DPD indices by evaluating the relationship between these indices and placental morphometry. Secondary objectives are (i) to determine the impact of machine settings and physical characteristics on 3DPD indices, and (ii) to evaluate physio-pathological placental vascularisation patterns. METHODS AND ANALYSIS This is a prospective controlled study. We expect to include 112 women: 84 with normal pregnancies and 28 with PE and/or IUGR (based on our former cohort study on 3DPD indices for PE and/or IUGR prediction (unpublished data)). Within 72 h before planned or semi-urgent caesarean section, utero-placental 3DPD images with five different machine settings will be acquired. Placentas will be collected and examined after surgery and stereological indices (volume density, surface density, length density) calculated. The 3DPD indices (VI, FI and VFI) of the placenta and adjacent myometrium will be calculated. Correlation between Doppler and morphological indices will be evaluated by Pearson or Spearman tests. Agreement between 3DPD indices and morphological indices will be assessed by Bland and Altman plots. The impact of Doppler settings and maternal characteristics on 3DPD indices will be evaluated with a multivariate linear regression model. ETHICS The study and related consent forms have been approved by the French Ethics Committee (CPP, Comité de Protection des Personnes) Est III on 4 March 2014.
Collapse
Affiliation(s)
- Jie Duan
- IADI, Inserm U947, University of Lorraine, Nancy, France
- Pôle de Gynécologie-Obstétrique, Service d'Obstétrique et Médecine Fœtale, CHRU Nancy, Nancy, France
| | - Anne-Claire Chabot-Lecoanet
- IADI, Inserm U947, University of Lorraine, Nancy, France
- Pôle de Gynécologie-Obstétrique, Service d'Obstétrique et Médecine Fœtale, CHRU Nancy, Nancy, France
| | - Estelle Perdriolle-Galet
- IADI, Inserm U947, University of Lorraine, Nancy, France
- Pôle de Gynécologie-Obstétrique, Service d'Obstétrique et Médecine Fœtale, CHRU Nancy, Nancy, France
| | - Christophe Christov
- Service Commun de Microscopie, Faculté de Médecine, University of Lorraine, Vandoeuvre-Lès-Nancy, France
- Laboratory of Fetal and Placental Pathology, CHRU Nancy, Nancy, France
| | | | | | - Olivier Morel
- IADI, Inserm U947, University of Lorraine, Nancy, France
- Pôle de Gynécologie-Obstétrique, Service d'Obstétrique et Médecine Fœtale, CHRU Nancy, Nancy, France
- PremUp Foundation, Paris, France
| |
Collapse
|
20
|
Farina A. Systematic review on first trimester three-dimensional placental volumetry predicting small for gestational age infants. Prenat Diagn 2016; 36:135-41. [DOI: 10.1002/pd.4754] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/17/2015] [Accepted: 11/25/2015] [Indexed: 11/07/2022]
Affiliation(s)
- Antonio Farina
- Division of Obstetrics and Gynecology; Department of Medicine and Surgery (DIMEC) University of Bologna; Bologna Italy
| |
Collapse
|
21
|
Neto RM, Ramos J. 3D power Doppler ultrasound in early diagnosis of preeclampsia. Pregnancy Hypertens 2016; 6:10-6. [DOI: 10.1016/j.preghy.2015.11.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2015] [Revised: 08/12/2015] [Accepted: 11/18/2015] [Indexed: 12/01/2022]
|
22
|
Stevenson GN, Collins SL, Ding J, Impey L, Noble JA. 3-D Ultrasound Segmentation of the Placenta Using the Random Walker Algorithm: Reliability and Agreement. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:3182-3193. [PMID: 26341043 DOI: 10.1016/j.ultrasmedbio.2015.07.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 07/07/2015] [Accepted: 07/16/2015] [Indexed: 06/05/2023]
Abstract
Volumetric segmentation of the placenta using 3-D ultrasound is currently performed clinically to investigate correlation between organ volume and fetal outcome or pathology. Previously, interpolative or semi-automatic contour-based methodologies were used to provide volumetric results. We describe the validation of an original random walker (RW)-based algorithm against manual segmentation and an existing semi-automated method, virtual organ computer-aided analysis (VOCAL), using initialization time, inter- and intra-observer variability of volumetric measurements and quantification accuracy (with respect to manual segmentation) as metrics of success. Both semi-automatic methods require initialization. Therefore, the first experiment compared initialization times. Initialization was timed by one observer using 20 subjects. This revealed significant differences (p < 0.001) in time taken to initialize the VOCAL method compared with the RW method. In the second experiment, 10 subjects were used to analyze intra-/inter-observer variability between two observers. Bland-Altman plots were used to analyze variability combined with intra- and inter-observer variability measured by intra-class correlation coefficients, which were reported for all three methods. Intra-class correlation coefficient values for intra-observer variability were higher for the RW method than for VOCAL, and both were similar to manual segmentation. Inter-observer variability was 0.94 (0.88, 0.97), 0.91 (0.81, 0.95) and 0.80 (0.61, 0.90) for manual, RW and VOCAL, respectively. Finally, a third observer with no prior ultrasound experience was introduced and volumetric differences from manual segmentation were reported. Dice similarity coefficients for observers 1, 2 and 3 were respectively 0.84 ± 0.12, 0.94 ± 0.08 and 0.84 ± 0.11, and the mean was 0.87 ± 0.13. The RW algorithm was found to provide results concordant with those for manual segmentation and to outperform VOCAL in aspects of observer reliability. The training of an additional untrained observer was investigated, and results revealed that with the appropriate initialization protocol, results for observers with varying levels of experience were concordant. We found that with appropriate training, the RW method can be used for fast, repeatable 3-D measurement of placental volume.
Collapse
Affiliation(s)
- Gordon N Stevenson
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, UK; Evelyn Perinatal Imaging Centre, Rosie Hospital, Cambridge, UK.
| | - Sally L Collins
- Nuffield Department of Obstetrics and Gynaecology, University of Oxford, Oxford, UK; Fetal Medicine Unit, The Women's Centre, John Radcliffe Hospital, Oxford, UK
| | - Jane Ding
- Nuffield Department of Obstetrics and Gynaecology, University of Oxford, Oxford, UK
| | - Lawrence Impey
- Fetal Medicine Unit, The Women's Centre, John Radcliffe Hospital, Oxford, UK
| | - J Alison Noble
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford, UK
| |
Collapse
|
23
|
Plasencia W, González-Dávila E, González Lorenzo A, Armas-González M, Padrón E, González-González NL. First trimester placental volume and vascular indices in pregnancies complicated by preeclampsia. Prenat Diagn 2015; 35:1247-54. [PMID: 26395429 DOI: 10.1002/pd.4692] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 09/02/2015] [Accepted: 09/02/2015] [Indexed: 12/16/2022]
Abstract
OBJECTIVE To analyze placental volume and vascularization at first trimester in women with pre-eclampsia, and secondarily, the effect of maternal characteristics on placental development and perinatal outcomes. METHODS This was a prospective cohort study including women seen between 11 and 14 weeks of pregnancy. Biophysical and biochemical markers included in the screening program for aneuploidy were recorded. Placental volume and vascularization indices were obtained using three-dimensional power-Doppler imaging and Virtual Organ Computer-aided Analysis (VOCAL) techniques. RESULTS We compared 84 women with pre-eclampsia versus 904 non-affected. Placental volume and all vascular indices were lower in those with pre-eclampsia. Multivariate analysis showed that parity and maternal weight had a significant effect on placental volume and vascularization indices (p = 0.004 and p = 0.011). In women with pre-eclampsia, multiparity showed a negative effect on placental volume, gestational age, birth weight and Apgar test score. By contrast, in the non-affected group, multiparity had a protective effect. Low maternal weight had a significantly worse effect on placental vascularization and perinatal outcomes in women with pre-eclampsia. CONCLUSIONS Women with pre-eclampsia showed significantly lower placental volume and vascularization indices at first trimester. Multiparity and low maternal weight independently exacerbated the negative effects of pre-eclampsia on placental characteristics and perinatal outcomes. © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
| | - Enrique González-Dávila
- Departamento de Matemáticas, Estadística e Investigación Operativa, Universidad de La Laguna, Canary Islands, Spain
| | - Alejandra González Lorenzo
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, Canary Islands, Spain
| | - Marina Armas-González
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, Canary Islands, Spain
| | - Erika Padrón
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, Canary Islands, Spain
| | - Nieves L González-González
- Departamento de Obstetricia y Ginecología, Hospital Universitario de Canarias, Universidad de La Laguna, Canary Islands, Spain
| |
Collapse
|
24
|
Yuan T, Zhang T, Han Z. Placental vascularization alterations in hypertensive disorders complicating pregnancy (HDCP) and small for gestational age with HDCP using three-dimensional power doppler in a prospective case control study. BMC Pregnancy Childbirth 2015; 15:240. [PMID: 26437940 PMCID: PMC4595287 DOI: 10.1186/s12884-015-0666-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 09/21/2015] [Indexed: 11/16/2022] Open
Abstract
Background Hypertensive disorders complicating pregnancy (HDCP) continues to be a leading cause of maternal and neonatal mortality and morbidity. The clinical value of placental three-dimensional power Doppler (3DPD) in assessing HDCP requires further confirmation. The research was developed to assess changes of placental vascularity in HDCP using 3DPD and to investigate the placental vascularity in small for gestational age (SGA) compared with not-SGA in patients with HDCP. Methods There were 126 normotensive and 128 hypertensive pregnant women included in this prospective case–control study from March 2011 to March 2013. Pregnant women underwent 3DPD. Vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained. The placental 3DPD indices, umbilical artery systolic and diastolic ratio (S/D) and pregnancy outcomes were compared between the groups. Results The placental VI and VFI were significantly lower in hypertensive women compared with normotensive women (P < 0.001 and P = 0.014, respectively), and these parameters were significantly reduced in severe preeclampsia (P < 0.001 and P = 0.003, respectively). A weak correlation was found between VI and umbilical artery S/D in HDCP group (r = -0.277, P = 0.001). In HDCP population, neonates who were postnatally diagnosed with SGA had lower VI (P = 0.041) and higher S/D (P < 0.001). Discussion The placental vascularity indices decreased in hypertensive women and the reduction inplacental perfusion was consistent with the severity of the hypertensive disorder. The associations betweenplacental vascularization and umbilical artery impedance may be valuable for further researches and arerequired confirmation. The significant differences in the 3DPD placental vascularization between SGA andnot-SGA in hypertensive pregnancy population may show some clinical importance that we could use tobetter assess or predict the progression and adverse outcomes in the future. Although 3DPD quantificationhas been widely used in multiple publications, we have to acknowledge its limitations. Conclusions The intraplacental vascularization was poor in HDCP, and especially in severe preeclampsia. Neonates with SGA had poor placental vascularization and higher umbilical artery S/D. Further studies should focus on the clinical assessment of placental 3DPD as well as a combination of placental 3DPD and other fetal Doppler indices to better predict the development and outcomes of preeclampsia.
Collapse
Affiliation(s)
- Ting Yuan
- Department of Obstetrics and Gynecology, First Affiliated Hospital of Xi'an Jiaotong University College of Medicine, Shaanxi, China.
| | - Ting Zhang
- Department of Obstetrics and Gynecology, First Affiliated Hospital of Xi'an Jiaotong University College of Medicine, Shaanxi, China.
| | - Zhen Han
- Department of Obstetrics and Gynecology, First Affiliated Hospital of Xi'an Jiaotong University College of Medicine, Shaanxi, China.
| |
Collapse
|
25
|
Park HJ, Shim SS, Cha DH. Combined Screening for Early Detection of Pre-Eclampsia. Int J Mol Sci 2015; 16:17952-74. [PMID: 26247944 PMCID: PMC4581230 DOI: 10.3390/ijms160817952] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 07/21/2015] [Accepted: 07/22/2015] [Indexed: 01/23/2023] Open
Abstract
Although the precise pathophysiology of pre-eclampsia remains unknown, this condition continues to be a major cause of maternal and fetal mortality. Early prediction of pre-eclampsia would allow for timely initiation of preventive therapy. A combination of biophysical and biochemical markers are superior to other tests for early prediction of the development of pre-eclampsia. Apart from the use of parameters in first-trimester aneuploidy screening, cell-free fetal DNA quantification is emerging as a promising marker for prediction of pre-eclampsia. This article reviews the current research of the most important strategies for prediction of pre-eclampsia, including the use of maternal risk factors, mean maternal arterial pressure, ultrasound parameters, and biomarkers.
Collapse
Affiliation(s)
- Hee Jin Park
- Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University, Seoul 135-081, Korea.
| | - Sung Shin Shim
- Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University, Seoul 135-081, Korea.
| | - Dong Hyun Cha
- Department of Obstetrics and Gynecology, CHA Gangnam Medical Center, CHA University, Seoul 135-081, Korea.
| |
Collapse
|
26
|
Farina A. Placental vascular indices (VI, FI and VFI) in intrauterine growth retardation (IUGR). A pooled analysis of the literature. Prenat Diagn 2015; 35:1065-72. [DOI: 10.1002/pd.4646] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2015] [Revised: 06/24/2015] [Accepted: 06/25/2015] [Indexed: 11/08/2022]
Affiliation(s)
- Antonio Farina
- Division of Obstetrics and Gynecology, Department of Medicine and Surgery (DIMEC); University of Bologna; Bologna Italy
| |
Collapse
|
27
|
Gurgel Alves JA, Maia e Holanda Moura SB, Araujo Júnior E, Tonni G, Martins WP, Da Silva Costa F. Predicting small for gestational age in the first trimester of pregnancy using maternal ophthalmic artery Doppler indices. J Matern Fetal Neonatal Med 2015; 29:1190-4. [DOI: 10.3109/14767058.2015.1040755] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
28
|
Arakaki T, Hasegawa J, Nakamura M, Hamada S, Muramoto M, Takita H, Ichizuka K, Sekizawa A. Prediction of early- and late-onset pregnancy-induced hypertension using placental volume on three-dimensional ultrasound and uterine artery Doppler. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2015; 45:539-543. [PMID: 25042564 DOI: 10.1002/uog.14633] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2014] [Revised: 05/21/2014] [Accepted: 07/07/2014] [Indexed: 06/03/2023]
Abstract
OBJECTIVES To determine whether uterine artery (UtA) Doppler findings and three-dimensional (3D) ultrasound measurement of placental volume during the first trimester allowed prediction of early- and late-onset pregnancy-induced hypertension (early PIH and late PIH). METHODS Subjects with singleton pregnancy who underwent an ultrasound scan at 11-13 weeks' gestation and delivered between 2011 and 2013 were enrolled prospectively into the study. The UtA Doppler indices and placental volume on 3D ultrasound at 11-13 weeks' gestation in cases that developed early PIH (< 34 weeks) or PIH later in pregnancy (≥ 34 weeks) were compared with values in unaffected pregnancies. RESULTS Ten cases of early PIH, 67 cases of late PIH and 1285 unaffected pregnancies were analyzed. The UtA pulsatility index (PI) was higher in cases of early PIH than that in unaffected pregnancies (median, 2.35 vs. 1.79; P = 0.043) but did not differ between cases of late PIH and unaffected pregnancies. Placental volume was smaller in cases of early PIH than that in unaffected pregnancies (median, 43 cm3 vs. 62 cm(3) ; P = 0.003) but did not differ between cases of late PIH and unaffected pregnancies. The area under the receiver-operating characteristics curve for the prediction of early PIH, by combining UtA-PI and placental volume, was 0.832 (95% CI, 0.742-0.921), with this combination providing a detection rate for early PIH of 67.5% for a 5% false-positive rate. CONCLUSIONS High UtA-PI and small placental volume were observed more often in cases of early PIH compared with unaffected pregnancies, but not in cases of late PIH. These results may indicate that there are differences in pathophysiology between early PIH and late PIH.
Collapse
Affiliation(s)
- T Arakaki
- Department of Obstetrics and Gynecology, Showa University School of Medicine, Tokyo, Japan
| | | | | | | | | | | | | | | |
Collapse
|
29
|
Tonni G, Martins WP, Guimarães Filho H, Araujo Júnior E. Role of 3-D ultrasound in clinical obstetric practice: evolution over 20 years. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1180-1211. [PMID: 25748522 DOI: 10.1016/j.ultrasmedbio.2014.12.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2014] [Revised: 12/10/2014] [Accepted: 12/11/2014] [Indexed: 06/04/2023]
Abstract
The use of 3-D ultrasound in obstetrics has undergone dramatic development over the past 20 years. Since the first publications on this application in clinical practice, several 3-D ultrasound techniques and rendering modes have been proposed and applied to the study of fetal brain, face and cardiac anatomy. In addition, 3-D ultrasound has improved calculations of the volume of fetal organs and limbs and estimations of fetal birth weight. And furthermore, angiographic patterns of fetal organs and the placenta have been assessed using 3-D power Doppler ultrasound quantification. In this review, we aim to summarize current evidence on the clinical relevance of these methodologies and their application in obstetric practice.
Collapse
Affiliation(s)
- Gabriele Tonni
- Department of Obstetrics and Gynecology, Guastalla Civil Hospital, ASL Reggio Emilia, Italy; Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Wellington P Martins
- Department of Obstetrics and Gynecology, Ribeirão Preto School of Medicine, University of São Paulo (DGO-FMRP-USP), Ribeirão Preto-SP, Brazil
| | | | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil.
| |
Collapse
|
30
|
Noguchi J, Tanaka H, Koyanagi A, Miyake K, Hata T. Three-dimensional power Doppler indices at 18–22 weeks’ gestation for prediction of fetal growth restriction or pregnancy-induced hypertension. Arch Gynecol Obstet 2014; 292:75-9. [DOI: 10.1007/s00404-014-3603-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Accepted: 12/16/2014] [Indexed: 10/24/2022]
|
31
|
Milligan N, Rowden M, Wright E, Melamed N, Lee YM, Windrim RC, Kingdom JC. Two-dimensional sonographic assessment of maximum placental length and thickness in the second trimester: a reproducibility study. J Matern Fetal Neonatal Med 2014; 28:1653-9. [DOI: 10.3109/14767058.2014.963047] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
32
|
Rosner M, Dar P, Reimers LL, McAndrew T, Gebb J. First-trimester 3D power Doppler of the uteroplacental circulation space and fetal growth restriction. Am J Obstet Gynecol 2014; 211:521.e1-8. [PMID: 24834864 DOI: 10.1016/j.ajog.2014.05.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Revised: 04/11/2014] [Accepted: 05/12/2014] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The objective of the study was to compare the 3-dimensional power Doppler (3DPD) of the uteroplacental circulation space in the first trimester between women who subsequently deliver growth-restricted vs normally grown neonates. STUDY DESIGN This was a prospective observational study of singleton pregnancies at 11-14 weeks' gestation. The 3DPD indices, vascularization index, flow index, and vascularization flow index were determined on a uteroplacental circulation space sphere biopsy with the virtual organ computer-aided analysis program. Growth restriction was defined as a birthweight less than the 10th percentile for gestational age and was evaluated using both population-based and customized birth curves. RESULTS Five hundred seventy-seven women were enrolled. Five hundred twenty-six were eligible for analysis using population centiles, and 497 were available for evaluation using customized centiles. There was no difference in the first-trimester 3DPD indices between patients with growth-restricted and normally grown neonates using either curve. CONCLUSION Three-dimensional power Doppler indices of the uteroplacental circulation space in the first trimester are similar between neonates who develop growth restriction and those who will grow normally.
Collapse
Affiliation(s)
- Mara Rosner
- Division of Fetal Medicine and Obstetrics and Gynecology Ultrasound, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY; Department of Obstetrics and Gynecology and Women's Health, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY.
| | - Pe'er Dar
- Division of Fetal Medicine and Obstetrics and Gynecology Ultrasound, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY; Department of Obstetrics and Gynecology and Women's Health, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY
| | - Laura L Reimers
- Department of Obstetrics and Gynecology and Women's Health, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY
| | - Thomas McAndrew
- Department of Obstetrics and Gynecology and Women's Health, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY
| | - Juliana Gebb
- Division of Fetal Medicine and Obstetrics and Gynecology Ultrasound, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY; Department of Obstetrics and Gynecology and Women's Health, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY
| |
Collapse
|
33
|
[Placental 3D Doppler angiography: current and upcoming applications]. ACTA ACUST UNITED AC 2014; 44:107-18. [PMID: 25307617 DOI: 10.1016/j.jgyn.2014.09.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2014] [Revised: 09/03/2014] [Accepted: 09/10/2014] [Indexed: 11/20/2022]
Abstract
The placental dysfunction, which seems to be caused by a defect of trophoblastic invasion and impaired uterine vascular remodeling since the first trimester, is responsible in a non-exclusive way for the chronic placental hypoxia, resulting secondarily in the intra-uterine growth restriction (IUGR) and/or pre-eclampsia (PE). The quality of utero-placental vasculature is essential for a proper fetal development and a successful progress of pregnancy. However, the in vivo assessment of placental vascularization with non-invasive methods is complicated by the small size of placental terminal vessel and its complex architecture. Moreover, imaging with contrast agent is not recommended to pregnant women. Until recently, the fetal and maternal vascularization could only be evaluated through pulse Doppler of uterine arteries during pregnancy, which has little clinical value for utero-placental vascularization defects assessment. Recently, a non-invasive study, without use of contrast agent for vasculature evaluation of an organ of interest has become possible by the development of 3D Doppler angiography technique. The objective of this review was to make an inventory of its current and future applications for utero-placental vasculature quantification. The main findings of the literature on the assessment of utero-placental vascularization in physiological situation and major placental vascular dysfunction pathologies such as PE and IUGR were widely discussed.
Collapse
|
34
|
Hashish N, Hassan A, El-Semary A, Gohar R, Youssef MAFM. Could 3D placental volume and perfusion indices measured at 11–14 weeks predict occurrence of preeclampsia in high-risk pregnant women? J Matern Fetal Neonatal Med 2014; 28:1094-8. [DOI: 10.3109/14767058.2014.943177] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
35
|
Farina A. Biophysical markers for abnormal placentation: first and/or second trimester. Prenat Diagn 2014; 34:628-34. [DOI: 10.1002/pd.4377] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2014] [Revised: 03/27/2014] [Accepted: 04/02/2014] [Indexed: 11/10/2022]
|
36
|
Hoopmann M, Schermuly S, Abele H, Zubke W, Kagan KO. First trimester pregnancy volumes and subsequent small for gestational age fetuses. Arch Gynecol Obstet 2014; 290:41-6. [PMID: 24496513 DOI: 10.1007/s00404-014-3162-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2013] [Accepted: 01/16/2014] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To examine whether in the first trimester, placental, gestational sac and fetal volumes are different in pregnancies that result in small for gestational age (SGA) compared to average for gestational age (AGA) neonates. METHODS Case-control study comparing first trimester 3D volumes of the placenta, the fetus and the gestational sac between SGA and AGA pregnancies. 3D volumes were acquired for quality assurance and documentation. Pregnancy volumes were calculated by the virtual organ computer-aided analysis technique. Linear regression analysis was used to compute a normal range for the placental, gestational sac and fetal volume based on the crown rump length (CRL) in AGA pregnancies. Multiple regression analysis was used to examine significant influencing covariates. A Student's t test was used to compare the difference between the SGA and AGA group. RESULTS The study population consisted of 19 first trimester pregnancies with subsequent SGA neonates and 105 control pregnancies. In the AGA group, all pregnancy volumes were significantly dependent on the CRL. After controlling the CRL effect, the placental, gestational sac and fetal volumes were not significantly different between the SGA and AGA group. CONCLUSION First trimester 3D pregnancy volume measurements are not different in SGA or AGA pregnancies.
Collapse
Affiliation(s)
- Markus Hoopmann
- Department of Obstetrics and Gynaecology, University of Tuebingen, Calwerstrasse 7, 72076, Tübingen, Germany
| | | | | | | | | |
Collapse
|
37
|
Abstract
Reduced fetal movement (RFM) is commonly defined as any reduction in maternal perception of fetal activity. Perceived fetal activity may be movement of limbs, trunk or head movement, but excludes fetal hiccoughs (as this is involuntary movement). The perception of fetal movement by an expectant mother is the first, and ongoing, non-sonographic indicator of fetal viability. The “normal” pattern of fetal movements varies from pregnancy to pregnancy, and often does not become established until 28 weeks’ gestation. Many babies have particularly active periods of the day, usually corresponding to periods of maternal rest and inactivity (which may in itself reflect increased maternal awareness of fetal movement). A variable percentage of sonographically observed fetal movements are perceived by prospective mothers (commonly 30–40%, although some studies report rates as high as 80%).
Collapse
|
38
|
The predictive value of first trimester fetal volume measurements, a prospective cohort study. Early Hum Dev 2013; 89:321-6. [PMID: 23253301 DOI: 10.1016/j.earlhumdev.2012.11.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2012] [Revised: 10/24/2012] [Accepted: 11/02/2012] [Indexed: 11/22/2022]
Abstract
OBJECTIVES To determine if fetal volume (FV) measurements with three-dimensional ultrasound in the first trimester of pregnancy can detect the fetus at risk for preterm birth and/or low birth weight. METHODS In this prospective cohort study, 538 participants were included during the routine first trimester ultrasound examination. Volume measurements were performed with VOCAL (9°). Firstly, the relation between FV and gestational age for a set of participants with normal pregnancies (training set), was assessed using multiple linear regression analysis, which was then used to determine the expected normal values. Secondly, for a new set of participants with normal pregnancies and a set of participants with complicated pregnancies (preterm birth and/or low birth weight), i.e. the validation set, the observed fetal volumes (FVobserved) were compared with their expected normal values (FVexpected) and expressed as a percentage of the expected normal value. The difference in mean percentage was then assessed with independent-samples t-test. Finally, logistic regression analysis was applied to the validation set to analyze the ability to predict the pregnancy outcome with FV calculation. RESULTS Linear regression analysis of FV as a predictor of preterm birth and/or low birth weight did not result in significant (p=0.630 and 0.290, respectively) or clinical relevant results (standardized effect sizes of 0.061 and 0.179, respectively). The predicting quality was also very low (AUC=0.508 and 0.545 respectively). CONCLUSIONS Fetal volume measurements in the first trimester of pregnancy are not useful as a prognostic tool for predicting pregnancies of high risk for preterm birth or a low birth weight.
Collapse
|
39
|
Nakamura M, Hasegawa J, Hamada S, Matsuoka R, Ichizuka K, Sekizawa A, Okai T. The volume of the chorion villosum is associated with the location of the umbilical cord in the first trimester. Prenat Diagn 2013; 33:759-63. [DOI: 10.1002/pd.4120] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2012] [Revised: 03/12/2013] [Accepted: 03/21/2013] [Indexed: 11/10/2022]
Affiliation(s)
- Masamitsu Nakamura
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Junichi Hasegawa
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Shoko Hamada
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Ryu Matsuoka
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Kiyotake Ichizuka
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Akihiko Sekizawa
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| | - Takashi Okai
- Department of Obstetrics and Gynecology; Showa University School of Medicine; Tokyo; Japan
| |
Collapse
|
40
|
Antsaklis A, Antsaklis P, Natsis S. Three-dimensional Evaluation of the Placenta: Review of the Literature. ACTA ACUST UNITED AC 2013. [DOI: 10.5005/jp-journals-10009-1272] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
ABSTRACT
The introduction of the three-dimensional (3D) ultrasound made feasible the quantitative and qualitative evaluation of the placenta's characteristics like the volume, the surface rendered imaging, the vascularization and the blood flow. These novel techniques may assist the early detection of pregnancies at high risk for fetal growth restriction (FGR), pre-eclampsia (PET) and pregnancy-induced hypertension (PIH) and help clinicians to detect pregnancies at risk earlier and to assess new therapeutic strategies in order to prevent adverse pregnancy outcomes. However, in this new technique there are still limitations regarding the assessment of the placenta employing 3D ultrasound in everyday clinical practice. In the following article, we perform a review of the literature regarding the importance of 3D evaluation of the placenta in pregnancy.
How to cite this article
Natsis S, Antsaklis P, Antsaklis A, Kurjak A. Three-dimensional Evaluation of the Placenta: Review of the Literature. Donald School J Ultrasound Obstet Gynecol 2013;7(1):73-79.
Collapse
|
41
|
Harris JM, Franck L, Michie S. Assessing the psychological effects of prenatal screening tests for maternal and foetal conditions: a systematic review. J Reprod Infant Psychol 2012. [DOI: 10.1080/02646838.2012.710834] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- James Matthew Harris
- a Department of Clinical, Educational and Health Psychology , University College London , London , UK
| | - Linda Franck
- b University of California–San Francisco, Family Health Care Nursing , San Francisco , CA , USA
| | - Susan Michie
- a Department of Clinical, Educational and Health Psychology , University College London , London , UK
| |
Collapse
|
42
|
Martins WP, Lima JC, Welsh AW, Araujo Júnior E, Miyague AH, Filho FM, Raine-Fenning NJ. Three-dimensional Doppler evaluation of single spherical samples from the placenta: intra- and interobserver reliability. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2012; 40:200-206. [PMID: 22173929 DOI: 10.1002/uog.11076] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVE To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. METHODS Women with singleton pregnancies at 24-40 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm(3) of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm(3) of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). RESULTS Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. CONCLUSION Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited.
Collapse
Affiliation(s)
- W P Martins
- Departamento de Ginecologia e Obstetrícia da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo (FMRP-USP), Ribeirão Preto, Brazil.
| | | | | | | | | | | | | |
Collapse
|
43
|
Rizzo G, Capponi A, Pietrolucci ME, Aiello E, Arduini D. First trimester placental volume and three dimensional power doppler ultrasonography in type I diabetic pregnancies. Prenat Diagn 2012; 32:480-4. [PMID: 22504827 DOI: 10.1002/pd.3848] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE This study aimed to investigate the placental volume and three dimensional (3D) power Doppler vascularization in type I diabetic pregnancies during the first trimester METHODS 3D-power Doppler ultrasonography of the placenta was performed at 11+0-13+6 weeks in 32 pregnancies complicated by type I diabetes. Placental volume, vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were calculated using a standardized setting. RESULTS In nine pregnancies, a poor first trimester glycemic control was present as expressed by HbA1c levels ≥ 7%, whereas in the remaining 23 mothers, the HbA1c concentrations were <7%. No differences were found in the placental volumes of diabetic mothers when compared with reference limits. 3D Doppler placental vascular indices were significantly higher in diabetic mothers (VI delta value 0.99, p=0.0012; FI delta value 0.64, p=0.0008; VFI delta value 1.28, p=0.0039) when compared with reference limits. Pregnancies with HbA1c ≥ 7% exhibited higher placental vascular indices when compared with diabetic mothers with better glycemic control. CONCLUSIONS In type I diabetic mothers, placental vascular indices are increased and these modifications are more evident in pregnancies with poor first trimester glycemic control.