1
|
Rojas AN, Mosquera FC. Advances and Challenges Associated with Low-Cost Pulse Oximeters in Home Care Programs: A Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:6284. [PMID: 39409324 PMCID: PMC11478359 DOI: 10.3390/s24196284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 08/28/2024] [Accepted: 09/09/2024] [Indexed: 10/20/2024]
Abstract
Oximeters have significantly evolved since their invention and are essential for monitoring chronic diseases in home care. However, commercial models can present an economic barrier. Therefore, we conducted a review of the use of low-cost pulse oximeters in the home care of patients with respiratory diseases. Our review included studies addressing oxygen saturation and heart rate monitoring in adults, focusing on the use of portable devices. Our search identified advances in vital signs monitoring that could provide accessible solutions for non-clinical settings. Although there are challenges related to clinical validation and accuracy, these oximeters may improve medical care, particularly in resource-limited areas. As a result, the accessibility of these devices opens up new possibilities for patients with chronic respiratory diseases in home care, enabling regular self-monitoring and increasing control over their health.
Collapse
Affiliation(s)
- Anisbed Naranjo Rojas
- Health and Education Research, Group (GINEYSA), Department of Health, Universidad Santiago de Cali, Cali 760001, Colombia
- Biomedicine Doctoral Program, Universidad de Córdoba, 14001 Córdoba, Spain
| | - Freiser Cruz Mosquera
- Integral Health Research Group (GISI), Department of Health, Universidad Santiago de Cali, Cali 760001, Colombia;
| |
Collapse
|
2
|
Hooli S, Makwenda C, Lufesi N, Colbourn T, Mvalo T, McCollum ED, King C. Implication of the 2014 World Health Organization Integrated Management of Childhood Illness Pneumonia Guidelines with and without pulse oximetry use in Malawi: A retrospective cohort study. Gates Open Res 2023; 7:71. [PMID: 37974907 PMCID: PMC10651692 DOI: 10.12688/gatesopenres.13963.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/03/2023] [Indexed: 11/19/2023] Open
Abstract
Background Under-5 pneumonia mortality remains high in low-income countries. In 2014 the World Health Organization (WHO) advised that children with chest indrawing pneumonia, but without danger signs or peripheral oxygen saturation (SpO 2) < 90% be treated in the community, rather than hospitalized. In Malawi there is limited pulse oximetry availability. Methods Secondary analysis of 13,413 under-5 pneumonia cases in Malawi. Pneumonia associated case fatality ratios (CFR) were calculated by disease severity under the assumptions of the 2005 and 2014 WHO Integrated Management of Childhood Illness (IMCI) guidelines, with and without pulse oximetry. We investigated if pulse oximetry readings were missing not at random (MNAR). Results The CFR of patients classified as having non-severe pneumonia per the 2014 IMCI guidelines doubled under the assumption that pulse oximetry was not available (1.5% without pulse oximetry vs 0.7% with pulse oximetry, P<0.001). When 2014 IMCI guidelines were applied with pulse oximetry and a SpO 2 < 90% as the threshold for referral and/or admission, the number of cases meeting hospitalization criteria decreased by 70.3%. Unrecorded pulse oximetry readings were MNAR with an adjusted odds for mortality of 4.9 (3.8, 6.3), similar to that of a SpO 2 < 90%. Although fewer girls were hospitalized, female sex was an independent mortality risk factor. Conclusions In Malawi, implementation of the 2014 WHO IMCI pneumonia guidelines, without pulse oximetry, will miss high risk cases. Alternatively, implementation of pulse oximetry may result in a large reduction in hospitalization rates without significantly increasing non-severe pneumonia associated CFR if the inability to obtain a pulse oximetry reading is considered a WHO danger sign.
Collapse
Affiliation(s)
- Shubhada Hooli
- Department of Pediatrics, Division of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA
| | | | - Norman Lufesi
- Republic of Malawi Ministry of Health, Lilongwe, Malawi
| | - Tim Colbourn
- Institute for Global Health, University College London, London, UK
| | - Tisungane Mvalo
- University of North Carolina Project Malawi, Lilongwe, Malawi
- Department of Pediatrics, University of North Carolina School of Medicine, Chapel Hill, NC, USA
| | - Eric D. McCollum
- Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
- Global Program in Respiratory Sciences, Eudowood Division of Pediatric Respiratory Sciences, Department of Pediatrics, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Carina King
- Institute for Global Health, University College London, London, UK
- Department of Global Public Health, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
3
|
Pfurtscheller T, Baker K, Habte T, Lasmi K, Matata L, Mucunguzi A, Nicholson J, Nuwa A, Petzold M, Posada González M, Sebsibe A, Alfvén T, Källander K. Usability of pulse oximeters used by community health and primary care workers as screening tools for severe illness in children under five in low resource settings: A cross-sectional study in Cambodia, Ethiopia, South Sudan, and Uganda. PLOS GLOBAL PUBLIC HEALTH 2023; 3:e0001800. [PMID: 37463164 DOI: 10.1371/journal.pgph.0001800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Accepted: 06/13/2023] [Indexed: 07/20/2023]
Abstract
Timely recognition and referral of severely ill children is especially critical in low-resource health systems. Pulse-oximeters can improve health outcomes of children by detecting hypoxaemia, a severity indicator of the most common causes of death in children. Cost-effectiveness of pulse-oximeters has been proven in low-income settings. However, evidence on their usability in community health settings is scarce.This study explores the usability of pulse-oximeters for community health and primary care workers in Cambodia, Ethiopia, South Sudan, and Uganda. We collected observational data, through a nine-task checklist, and survey data, using a five-point Likert scale questionnaire, capturing three usability aspects (effectiveness, efficiency, and satisfaction) of single-probe fingertip and multi-probe handheld devices. Effectiveness was determined by checklist completion rates and task completion rates per checklist item. Efficiency was reported as proportion of successful assessments within three attempts. Standardized summated questionnaire scores (min = 0, max = 100) determined health worker's satisfaction. Influencing factors on effectiveness and satisfaction were explored through hypothesis tests between independent groups (device type, cadre of health worker, country). Checklist completion rate was 78.3% [CI 72.6-83.0]. Choosing probes according to child age showed the lowest task completion rate of 68.7% [CI 60.3%-76.0%]. In 95.6% [CI 92.7%-97.4%] of assessments a reading was obtained within three attempts. The median satisfaction score was 95.6 [IQR = 92.2-99.0]. Significantly higher checklist completion rates were observed with single-probe fingertip devices (p<0.001) and children 12-59 months (p<0.001). We found higher satisfaction scores in South Sudan (p<0.001) and satisfaction varied slightly between devices. From a usability perspective single-probe devices for all age groups should be prioritized for scaled implementation. Further research on easy to use and accurate devices for infants is much needed.
Collapse
Affiliation(s)
- Theresa Pfurtscheller
- Department of Global Public Health, Karolinska Institutet, Solna, Sweden
- Malaria Consortium, London, United Kingdom
| | - Kevin Baker
- Department of Global Public Health, Karolinska Institutet, Solna, Sweden
- Malaria Consortium, London, United Kingdom
| | - Tedila Habte
- Malaria Consortium Ethiopia, Addis Ababa, Ethiopia
| | - Kévin Lasmi
- Department of Global Public Health, Karolinska Institutet, Solna, Sweden
| | - Lena Matata
- Swiss Tropical and Public Health Institute, Basel, Switzerland
- Malaria Consortium South Sudan, Aweil/Juba, South Sudan
| | | | | | | | - Max Petzold
- School of Public Health and Community Medicine, University of Gothenburg, Gothenburg, Sweden
| | | | | | - Tobias Alfvén
- Department of Global Public Health, Karolinska Institutet, Solna, Sweden
- Sach's children and youth hospital, Stockholm, Sweden
| | - Karin Källander
- Department of Global Public Health, Karolinska Institutet, Solna, Sweden
- UNICEF, New York, New York, United States of America
| |
Collapse
|
4
|
Sheikh M, Ahmad H, Ibrahim R, Nisar I, Jehan F. Pulse oximetry: why oxygen saturation is still not a part of standard pediatric guidelines in low-and-middle-income countries (LMICs). Pneumonia (Nathan) 2023; 15:3. [PMID: 36739442 PMCID: PMC9899156 DOI: 10.1186/s41479-023-00108-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 01/13/2023] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND With the high frequency of acute respiratory infections in children worldwide, particularly so in low-resource countries, the development of effective diagnostic support is crucial. While pulse oximetry has been found to be an acceptable method of hypoxemia detection, improving clinical decision making and efficient referral, many healthcare set ups in low- and middle-income countries have not been able to implement pulse oximetry into their practice. MAIN BODY A review of past pulse oximetry implementation attempts in low- and middle-income countries proposes the barriers and potential solutions for complete integration in the healthcare systems. The addition of pulse oximetry into WHO health guidelines would prove to improve detection of respiratory distress and ensuing therapeutic measures. Incorporation is limited by the cost and unavailability of pulse oximeters, and subsequent oxygen accessibility. This restriction is compounded by the lack of trained personnel, and healthcare provider misconceptions. These hurdles can be combated by focus on low-cost devices, and cooperation at national levels for development in healthcare infrastructure, resource transport, and oxygen delivery systems. CONCLUSION The implementation of pulse oximetry shows promise to improve child morbidity and mortality from pneumonia in low- and middle-income countries. Steady measures taken to improve access to pulse oximeters and oxygen supplies, along with enhanced medical provider training are encouraging steps to thorough pulse oximetry integration.
Collapse
Affiliation(s)
- Maheen Sheikh
- grid.7147.50000 0001 0633 6224Department of Pediatrics and Child Health, Aga Khan University, Karachi, 74800 Pakistan
| | - Huzaifa Ahmad
- grid.415235.40000 0000 8585 5745Department of Medicine, MedStar Washington Hospital Center, Washington, DC 20010 USA
| | - Romesa Ibrahim
- grid.7147.50000 0001 0633 6224Department of Pediatrics and Child Health, Aga Khan University, Karachi, 74800 Pakistan
| | - Imran Nisar
- grid.7147.50000 0001 0633 6224Department of Pediatrics and Child Health, Aga Khan University, Karachi, 74800 Pakistan
| | - Fyezah Jehan
- grid.7147.50000 0001 0633 6224Department of Pediatrics and Child Health, Aga Khan University, Karachi, 74800 Pakistan
| |
Collapse
|
5
|
Rahman AE, Ameen S, Hossain AT, Jabeen S, Majid T, AFM AU, Tanwi TS, Banik G, Shaikh MZH, Islam MJ, Ashrafee S, Alam HMS, Saberin A, ANM EK, Ahmed S, Khan M, Ahmed A, Rahman QSU, Chisti MJ, Cunningham S, Islam MS, Dockrell DH, Nair H, El Arifeen S, Campbell H. Success and time implications of SpO 2 measurement through pulse oximetry among hospitalised children in rural Bangladesh: Variability by various device-, provider- and patient-related factors. J Glob Health 2022; 12:04036. [PMID: 35493782 PMCID: PMC9041243 DOI: 10.7189/jogh.12.04036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Background Hypoxaemia is one of the strongest predictors of mortality among children with pneumonia. It can be identified through pulse oximetry instantaneously, which is a non-invasive procedure but can be influenced by factors related to the specific measuring device, health provider and patient. Following WHO's global recommendation in 2014, Bangladesh decided to introduce pulse oximetry in paediatric outpatient services, ie, the Integrated Management of Childhood Illness (IMCI) services in 2019. A national committee updated the existing IMCI implementation package and decided to test it by assessing the pulse oximetry performance of different types of assessors in real-life inpatient settings. Methods We adopted an observational design and conducted a technology assessment among children admitted to a rural district hospital. Eleven nurses and seven paramedics received one-day training on pulse oximetry as assessors. Each assessor performed at least 30 pulse oximetry measurements on children with two types of handheld devices. The primary outcome of interest was obtaining a successful measurement of SpO2, defined as observing a stable (±1%) reading for at least 10 seconds. Performance time, ie, time taken to obtain a successful measurement of SpO2 was considered the secondary outcome of interest. In addition, we used Generalized Estimating Equation to assess the effect of different factors on the pulse oximetry performance. Results The assessors obtained successful measurements of SpO2 in all attempts (n = 1478) except one. The median time taken was 30 (interquartile range (IQR) = 22-42) seconds, and within 60 seconds, 92% of attempts were successful. The odds of obtaining a successful measurement within 60 seconds were 7.3 (95% confidence interval (CI) = 3.7-14.2) times higher with a Masimo device than a Lifebox device. Similarly, assessors aged >25 years were 4.8 (95% CI = 1.2, 18.6) times more likely to obtain a successful measurement within 60 seconds. The odds of obtaining a successful measurement was 2.6 (95% CI = 1.6, 4.2) times higher among children aged 12-59 months compared to 2-11 months. Conclusions Our study indicated that assessors could achieve the necessary skills to perform pulse oximetry successfully in real-life inpatient settings through a short training module, with some effect of device-, provider- and patient-related factors. The National IMCI Programme of Bangladesh can use these findings for finalising the national IMCI training modules and implementation package incorporating the recommendation of using pulse oximetry for childhood pneumonia assessment.
Collapse
Affiliation(s)
- Ahmed Ehsanur Rahman
- NIHR Global Health Research Unit on Respiratory Health (RESPIRE), Usher Institute, The University of Edinburgh
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Shafiqul Ameen
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Aniqa Tasnim Hossain
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Sabrina Jabeen
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Tamanna Majid
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Azim Uddin AFM
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Tania Sultana Tanwi
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | | | - Md Ziaul Haque Shaikh
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Md Jahurul Islam
- Directorate General of Health Services, Ministry of Health and Family Welfare, Government of Bangladesh
| | - Sabina Ashrafee
- Directorate General of Health Services, Ministry of Health and Family Welfare, Government of Bangladesh
| | - Husam Muhammad Shah Alam
- Directorate General of Health Services, Ministry of Health and Family Welfare, Government of Bangladesh
| | - Ashfia Saberin
- Directorate General of Health Services, Ministry of Health and Family Welfare, Government of Bangladesh
| | | | | | | | - Anisuddin Ahmed
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Qazi Sadeq-ur Rahman
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Mohammod Jobayer Chisti
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Steve Cunningham
- NIHR Global Health Research Unit on Respiratory Health (RESPIRE), Usher Institute, The University of Edinburgh
| | - Muhammad Shariful Islam
- Directorate General of Health Services, Ministry of Health and Family Welfare, Government of Bangladesh
| | - David H Dockrell
- NIHR Global Health Research Unit on Respiratory Health (RESPIRE), Usher Institute, The University of Edinburgh
| | - Harish Nair
- NIHR Global Health Research Unit on Respiratory Health (RESPIRE), Usher Institute, The University of Edinburgh
| | - Shams El Arifeen
- Maternal and Child Health Division, icddr,b (International Centre for Diarrhoeal Disease Research, Bangladesh), Dhaka, Bangladesh
| | - Harry Campbell
- NIHR Global Health Research Unit on Respiratory Health (RESPIRE), Usher Institute, The University of Edinburgh
| |
Collapse
|
6
|
King C, Baker K, Richardson S, Wharton-Smith A, Bakare AA, Jehan F, Chisti MJ, Zar H, Awasthi S, Smith H, Greenslade L, Qazi SA. Paediatric pneumonia research priorities in the context of COVID-19: An eDelphi study. J Glob Health 2022; 12:09001. [PMID: 35265333 PMCID: PMC8874896 DOI: 10.7189/jogh.12.09001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Background Pneumonia remains the leading cause of infectious deaths in children under-five globally. We update the research priorities for childhood pneumonia in the context of the COVID-19 pandemic and explore whether previous priorities have been addressed. Methods We conducted an eDelphi study from November 2019 to June 2021. Experts were invited to take part, targeting balance by: gender, profession, and high (HIC) and low- and middle-income countries (LMIC). We followed a three-stage approach: 1. Collating questions, using a list published in 2011 and adding newly posed topics; 2. Narrowing down, through participant scoring on importance and whether they had been answered; 3. Ranking of retained topics. Topics were categorized into: prevent and protect, diagnosis, treatment and cross-cutting. Results Overall 379 experts were identified, and 108 took part. We started with 83 topics, and 81 further general and 40 COVID-19 specific topics were proposed. In the final ranking 101 topics were retained, and the highest ranked was to “explore interventions to prevent neonatal pneumonia”. Among the top 20 topics, epidemiological research and intervention evaluation was commonly prioritized, followed by the operational and implementation research. Two COVID-19 related questions were ranked within the top 20. There were clear differences in priorities between HIC and LMIC respondents, and academics vs non-academics. Conclusions Operational research on health system capacities, and evaluating optimized delivery of existing treatments, diagnostics and case management approaches are needed. This list should act as a catalyst for collaborative research, especially to meet the top priority in preventing neonatal pneumonia, and encourage multi-disciplinary partnerships.
Collapse
Affiliation(s)
- Carina King
- Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
- Institute for Global Health, University College London, London, UK
| | - Kevin Baker
- Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
- Malaria Consortium, London, UK
| | | | | | - Ayobami A Bakare
- Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
- Department of Community Medicine, University College Hospital Ibadan, Ibadan, Nigeria
| | - Fyezah Jehan
- Department of Paediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| | - Mohammod Jobayer Chisti
- Nutrition and Clinical Services Division, International Centre for Diarrhoeal Disease Research Bangladesh (icddr,b), Dhaka, Bangladesh
| | - Heather Zar
- Department of Paediatrics and Child Health and SA-MRC Unit on Child & Adolescent Health, University of Cape Town, Cape Town, South Africa
| | - Shally Awasthi
- Department of Paediatrics, King George’s Medical University, Lucknow, India
| | - Helen Smith
- Malaria Consortium, London, UK
- Consultant, International Health Consulting Services Ltd, UK
| | | | - Shamim A Qazi
- Consultant, Retired staff World Health Organization, Geneva, Switzerland
| |
Collapse
|
7
|
Baker K, Ward C, Maurel A, de Cola MA, Smith H, Getachew D, Habte T, McWhorter C, LaBarre P, Karlstrom J, Ameha A, Tariku A, Black J, Bassat Q, Källander K. Usability and acceptability of a multimodal respiratory rate and pulse oximeter device in case management of children with symptoms of pneumonia: A cross-sectional study in Ethiopia. Acta Paediatr 2021; 110:1620-1632. [PMID: 33220086 PMCID: PMC8246879 DOI: 10.1111/apa.15682] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/10/2020] [Accepted: 11/19/2020] [Indexed: 11/29/2022]
Abstract
Aim Pneumonia is the leading infectious cause of death among children under five globally. Many pneumonia deaths result from inappropriate treatment due to misdiagnosis of signs and symptoms. This study aims to identify whether health extension workers (HEWs) in Ethiopia, using an automated multimodal device (Masimo Rad‐G), adhere to required guidelines while assessing and classifying under five children with cough or difficulty breathing and to understand device acceptability. Methods A cross‐sectional study was conducted in three districts of Southern Nations, Nationalities, and Peoples' Region, Ethiopia. Between September and December 2018, 133 HEWs were directly observed using Rad‐G while conducting 599 sick child consultations. Usability was measured as adherence to the World Health Organization requirements to assess fast breathing and device manufacturer instructions for use. Acceptability was assessed using semi‐structured interviews with HEWs, first‐level health facility workers and caregivers. Results Adherence using the Rad‐G routinely for 2 months was 85.3% (95% CI 80.2, 89.3). Health workers and caregivers stated a preference for Rad‐G. Users highlighted a number of device design issues. Conclusion While demonstrating high levels of acceptability and usability, the device modifications to consider include better probe fit, improved user interface with exclusive age categories and simplified classification outcomes.
Collapse
Affiliation(s)
- Kevin Baker
- Malaria Consortium London UK
- Department of Global Public Health Karolinska Institutet Solna Sweden
| | | | | | | | | | | | | | | | | | | | | | | | - Jim Black
- Nossal Institute for Global Health Melbourne School of Population and Global Health The University of Melbourne Parkville Vic. Australia
| | - Quique Bassat
- ISGlobal Hospital Clínic ‐ Universitat de Barcelona Barcelona Spain
- Centro de Investigação em Saúde de Manhiça (CISM) Maputo Mozambique
- ICREA Barcelona Spain
- Paediatric Infectious Diseases Unit Paediatrics Department Hospital Sant Joan de Déu (University of Barcelona) Barcelona Spain
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP) Madrid Spain
| | - Karin Källander
- Malaria Consortium London UK
- Department of Global Public Health Karolinska Institutet Solna Sweden
- Programme Division UNICEF New York NY USA
| |
Collapse
|
8
|
Hooli S, King C, Zadutsa B, Nambiar B, Makwenda C, Masache G, Lufesi N, Mwansambo C, Malla L, Costello A, Colbourn T, McCollum ED. The Epidemiology of Hypoxemic Pneumonia among Young Infants in Malawi. Am J Trop Med Hyg 2020; 102:676-683. [PMID: 31971153 DOI: 10.4269/ajtmh.19-0516] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
We describe hypoxemic pneumonia prevalence in outpatient and inpatient settings, in-hospital mortality, and clinical guideline performance for identifying hypoxemia in young infants in Malawi. In this retrospective analysis of a prospective cohort study, we investigate infants younger than 2 months participating in pneumonia surveillance at seven hospitals and 18 outpatient health centers in Malawi between 2011 and 2014. Logistic regression, multiple imputation with chained equations, and pattern mixture modeling were used to determine the association between peripheral capillary oxyhemoglobin saturation (SpO2) levels and hospital mortality. We describe outpatient clinician hospital referral recommendations based on clinical characteristics and SpO2 distributions. Among 1,879 analyzed cases, SpO2 < 90% was more prevalent among outpatient health center cases compared with hospitalized cases (22.6% versus 13.5%, 95% CI: 17.6-28.4% and 12.0-15.3%, respectively). A larger proportion of hospitalized infants had signs of respiratory distress compared with infants at health centers (67.7% versus 56.6%, P < 0.001) and most hospitalized infants were boys (56.7% versus 40.6%, P < 0.001). An SpO2 of 90-92% and < 90% was associated with similarly increased odds of in-hospital mortality (adjusted odds ratio [aOR]: 4.3 and 4.4, 95% CI: 1.7-11.1 and 1.8-10.5, respectively). Unrecorded, or unobtainable, SpO2 was highly associated with mortality (n = 127, aOR: 18.1; 95% CI: 7.6-42.8). Four of 22 (18%) infants at health centers who did not meet clinical referral criteria had an SpO2 ≤ 92%. Clinicians should consider hospital referral in young infants with a SpO2 ≤ 92%. Infants with unobtainable SpO2 readings should be considered a high-risk group, and hospital referral of these cases may be appropriate.
Collapse
Affiliation(s)
- Shubhada Hooli
- Department of Pediatrics, Section of Emergency Medicine, Baylor College of Medicine, Houston, Texas
| | - Carina King
- Institute for Global Health, University College London, London, United Kingdom.,Department of Global Public Health, Karolinksa Institutet, Stockholm, Sweden
| | | | - Bejoy Nambiar
- Institute for Global Health, University College London, London, United Kingdom
| | | | | | - Norman Lufesi
- Republic of Malawi Ministry of Health, Lilongwe, Malawi
| | | | - Lucas Malla
- Kenya Medical Research Institute-Wellcome Trust, Nairobi, Kenya
| | - Anthony Costello
- Institute for Global Health, University College London, London, United Kingdom
| | - Tim Colbourn
- Institute for Global Health, University College London, London, United Kingdom
| | - Eric D McCollum
- Division of Pulmonology, Department of Pediatrics, Johns Hopkins School of Medicine, Baltimore, Maryland.,Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| |
Collapse
|
9
|
Graham H, Bakare AA, Ayede AI, Oyewole OB, Gray A, Peel D, McPake B, Neal E, Qazi SA, Izadnegahdar R, Duke T, Falade AG. Hypoxaemia in hospitalised children and neonates: A prospective cohort study in Nigerian secondary-level hospitals. EClinicalMedicine 2019; 16:51-63. [PMID: 31832620 PMCID: PMC6890969 DOI: 10.1016/j.eclinm.2019.10.009] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2019] [Accepted: 10/15/2019] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Hypoxaemia is a common complication of pneumonia and a major risk factor for death, but less is known about hypoxaemia in other common conditions. We evaluated the epidemiology of hypoxaemia and oxygen use in hospitalised neonates and children in Nigeria. METHODS We conducted a prospective cohort study among neonates and children (<15 years of age) admitted to 12 secondary-level hospitals in southwest Nigeria (November 2015-November 2017) using data extracted from clinical records (documented during routine care). We report summary statistics on hypoxaemia prevalence, oxygen use, and clinical predictors of hypoxaemia. We used generalised linear mixed-models to calculate relative odds of death (hypoxaemia vs not). FINDINGS Participating hospitals admitted 23,926 neonates and children during the study period. Pooled hypoxaemia prevalence was 22.2% (95%CI 21.2-23.2) for neonates and 10.2% (9.7-10.8) for children. Hypoxaemia was common among children with acute lower respiratory infection (28.0%), asthma (20.4%), meningitis/encephalitis (17.4%), malnutrition (16.3%), acute febrile encephalopathy (15.4%), sepsis (8.7%) and malaria (8.5%), and neonates with neonatal encephalopathy (33.4%), prematurity (26.6%), and sepsis (21.0%). Hypoxaemia increased the adjusted odds of death 6-fold in neonates and 7-fold in children. Clinical signs predicted hypoxaemia poorly, and their predictive ability varied across ages and conditions. Hypoxaemic children received oxygen for a median of 2-3 days, consuming ∼3500 L of oxygen per admission. INTERPRETATION Hypoxaemia is common in respiratory and non-respiratory acute childhood illness and increases the risk of death substantially. Given the limitations of clinical signs, pulse oximetry is an essential tool for detecting hypoxaemia, and should be part of the routine assessment of all hospitalised neonates and children.
Collapse
Affiliation(s)
- Hamish Graham
- Department of Paediatrics, University College Hospital, Ibadan, Nigeria
- Centre for International Child Health, University of Melbourne, MCRI, Royal Children's Hospital, Parkville, Australia
- Corresponding author at: Centre for International Child Health, Department of Paediatrics, Level 2 East, 50 Flemington Road, Parkville, VIC 3052, Australia.
| | - Ayobami A. Bakare
- Department of Paediatrics, University College Hospital, Ibadan, Nigeria
| | - Adejumoke I. Ayede
- Department of Paediatrics, University College Hospital, Ibadan, Nigeria
- Department of Paediatrics, University of Ibadan, Ibadan, Nigeria
| | | | - Amy Gray
- Centre for International Child Health, University of Melbourne, MCRI, Royal Children's Hospital, Parkville, Australia
| | | | - Barbara McPake
- Nossal Institute of Global Health, University of Melbourne, Parkville, Australia
| | - Eleanor Neal
- Centre for International Child Health, University of Melbourne, MCRI, Royal Children's Hospital, Parkville, Australia
- Pneumococcal Research, MCRI, Royal Children's Hospital, Parkville, Australia
| | - Shamim A. Qazi
- Department of Maternal, Newborn, Child and Adolescent Health, World Health Organization, Geneva, Switzerland
| | | | - Trevor Duke
- Centre for International Child Health, University of Melbourne, MCRI, Royal Children's Hospital, Parkville, Australia
| | - Adegoke G. Falade
- Department of Paediatrics, University College Hospital, Ibadan, Nigeria
- Department of Paediatrics, University of Ibadan, Ibadan, Nigeria
| |
Collapse
|
10
|
Pulse oximetry in paediatric primary care in low-income and middle-income countries. THE LANCET RESPIRATORY MEDICINE 2019; 7:1001-1002. [PMID: 31631030 DOI: 10.1016/s2213-2600(19)30358-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 09/27/2019] [Indexed: 11/20/2022]
|
11
|
King C, Mvalo T, Sessions K, Wilson I, Walker I, Zadutsa B, Makwenda C, Phiri T, Boyd N, Bernstein M, McCollum ED. Performance of a novel reusable pediatric pulse oximeter probe. Pediatr Pulmonol 2019; 54:1052-1059. [PMID: 30912314 PMCID: PMC6591029 DOI: 10.1002/ppul.24295] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 01/23/2019] [Accepted: 02/04/2019] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To assess the performance of reusable pulse oximeter probe and microprocessor box combinations, of varying price-points, in the context of a low-income pediatric setting. METHODS A prospective, randomized cross-over study comparing time to biologically plausible oxygen saturation (SpO2 ) between: (1) Lifebox LB-01 probe with Masimo Rad-87 box (L + M) and (2) a weight-appropriate reusable Masimo probe with Masimo Rad-87 box (M + M). A post hoc secondary analysis comparison with historical usability testing data with the Lifebox LB-01 probe and Lifebox V1.5 box (L + L) was also conducted. Participants, children aged 0 to 35 months, were recruited from pediatric wards and outpatient clinics in the central region of Malawi. The primary outcome was time taken to achieve a biologically plausible SpO 2 measurement, compared using t tests for equivalence. RESULTS We recruited 572 children. Plausible SpO2 measurements were obtained in less than 1 minute, 71%, 70%, and 63% for the M + M, L + M, and L + L combinations, respectively. A similar pattern was seen for less than 2 minutes, however, this effect disappeared at less than 5 minutes with 96%, 96%, and 95% plausible measurements. Using a ±10 second threshold for equivalence, we found L + M and M + M to be equivalent, but were under-powered to assess equivalence for L + L. CONCLUSIONS The novel reusable pediatric Lifebox probe can achieve a quality SpO2 measurement within a pragmatic time range of weight-appropriate Masimo equivalent probes. Further research, which considers the cost of the devices, is needed to assess the added value of sophisticated motion tolerance software.
Collapse
Affiliation(s)
- Carina King
- Institute for Global Health, University College London, London, UK.,Department of Public Health Sciences, Karolinska Institutet, Stockholm, Sweden
| | - Tisungane Mvalo
- University of North Carolina Project Malawi, Lilongwe, Malawi.,Department of Pediatrics, University of North Carolina, Chapel Hill, North Carolina
| | | | | | - Isabeau Walker
- Lifebox Foundation, London, UK.,Great Ormond Street Hospital, London, UK.,Institute for Child Health, University College London, London, UK
| | | | | | - Tambosi Phiri
- Parent and Child Health Initiative, Lilongwe, Malawi
| | - Nicholas Boyd
- King's Sierra Leona Partnership, Freetown, Sierra Leone
| | | | - Eric D McCollum
- Department of Pediatrics, Eudowood Division of Pediatric Respiratory Sciences, Johns Hopkins School of Medicine, Baltimore, Maryland.,Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
| |
Collapse
|