1
|
Ficial B, Dolce P, Petoello E, Flore AI, Nogara S, Ciarcià M, Brancolini G, Alfarano A, Marzollo R, Bosio I, Raimondi F, Risso FM, Beghini R, Dani C, Benfari G, Ribichini FL, Corsini I. Left atrial strain assessment unveils left ventricular diastolic dysfunction in neonates with transient tachypnea of the newborn: A prospective observational study. Pediatr Pulmonol 2024. [PMID: 38953730 DOI: 10.1002/ppul.27156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 06/02/2024] [Accepted: 06/20/2024] [Indexed: 07/04/2024]
Abstract
INTRODUCTION An inadequate clearance of lung fluid plays a key role in the pathogenesis of transient tachypnea of the newborn (TTN). OBJECTIVES To evaluate if left ventricular diastolic dysfunction contributes to reduced clearance of lung fluid in TTN. MATERIALS AND METHODS This was a prospective, observational study. Echocardiography and lung ultrasound were performed at 2, 24 and 48 h of life (HoL) to assess biventricular function and calculate lung ultrasound score (LUS). Left atrial strain reservoir (LASr) provided surrogate measurement of left ventricular diastolic function. RESULTS Twenty-seven neonates with TTN were compared with 27 controls with no difference in gestation (36.1 ± 2 vs. 36.9 ± 2 weeks) or birthweight (2508 ± 667 vs. 2718 ± 590 g). Biventricular systolic function was normal in both groups. LASr was significantly lower in cases at 2 (21.0 ± 2.7 vs. 38.1 ± 4.4; p < 0.01), 24 (25.2 ± 4.5 vs. 40.6 ± 4.0; p < 0.01) and 48 HoL (36.5 ± 5.8 and 41.6 ± 5.2; p < 0.01), resulting in a significant group by time interaction (p < 0.001), after adjusting for LUS and gestational diabetes. A logistic regression model including LUS, birth weight and gestational diabetes as covariates, showed that LASr at 2 HoL was a predictor of respiratory support at 24 HoL, with an adjusted odds ratio of 0.60 (CI 0.36-0.99). CONCLUSIONS LASr was reduced in neonates with TTN, suggesting diastolic dysfunction, that may contribute to the delay in lung fluid clearance.
Collapse
Affiliation(s)
- Benjamim Ficial
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Pasquale Dolce
- Department of Translational Medical Science, University of Naples Federico II, Naples, Italy
| | - Enrico Petoello
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Alice Iride Flore
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Silvia Nogara
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Martina Ciarcià
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Giovanna Brancolini
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Angela Alfarano
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Roberto Marzollo
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Ilaria Bosio
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Francesco Raimondi
- Division of Neonatology and Department of Translational Medical Sciences, Università "Federico II" di Napoli, Naples, Italy
| | - Francesco Maria Risso
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Renzo Beghini
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Carlo Dani
- Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Giovanni Benfari
- Section of Cardiology, Department of Medicine, University of Verona, Verona, Italy
| | | | - Iuri Corsini
- Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| |
Collapse
|
2
|
Abdelrazek AA, Kamel SM, Elbakry AAE, Elmazzahy EA. Lung ultrasound in early prediction of bronchopulmonary dysplasia in pre-term babies. J Ultrasound 2024:10.1007/s40477-024-00913-9. [PMID: 38907789 DOI: 10.1007/s40477-024-00913-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Accepted: 04/28/2024] [Indexed: 06/24/2024] Open
Abstract
PURPOSE Bronchopulmonary dysplasia (BPD) is a respiratory morbidity related to prematurity. Early prediction of BPD allows the selection of patients who would benefit from new therapies. Lung ultrasound (LUS) is a non-invasive diagnostic tool that has proven to be reliable for many neonatal diseases recently. The study aimed to detect the role of LUS in predicting BPD at days 7 and 14 of life in preterm babies. METHODS This was a prospective cohort study that included 95 preterm babies ≤ 34 weeks. Lung ultrasounds were performed on days 7 and 14 of life. RESULTS The mean gestational age of the studied neonates was 30.25 ± 2.21 weeks. The mean birth weight was 1347.66 ± 432.14 gm. Patients who developed BPD had statistically significantly higher LUS scores on both days 7 and 14 of life. At first examination, a LUS score > 8 showed a sensitivity of 83.33% and a specificity of 60.87%, whereas at follow-up, a LUS score > 8 showed a sensitivity of 76.39% and a specificity of 82.61%. The multivariate logistic regression analysis shows that the most important factors associated with BPD were gestational age ≤ 30 weeks, LUS score at first examination > 8, platelets ≤ 245 × 109/L, segment neutrophils ≤ 42%, and CRP > 5 mg/l. CONCLUSIONS The LUS score predicts BPD at 7 and 14 days of life. LUS scores increased with increasing BPD severity. LUS score > 8 was an independent factor in the prediction of BPD.
Collapse
Affiliation(s)
| | - Sara Mahmoud Kamel
- Diagnostic and Intervention Radiology Department, Cairo University Hospitals, Kasr Al-Ainy, Cairo, Egypt
| | | | - Esraa Ahmed Elmazzahy
- Department of Pediatrics, Cairo University Children's Hospital, Cairo, Egypt.
- AboulRish Children Hospital, 1 Aly Ibrahim Bash St, Sayeda Zeinab, Cairo, 11617, Egypt.
| |
Collapse
|
3
|
Corsini I, Lenzi MB, Ciarcià M, Matina F, Petoello E, Flore AI, Nogara S, Gangemi A, Fusco M, Capasso L, Raimondi F, Rodriguez-Fanjul J, Dani C, Ficial B. Comparison among three lung ultrasound scores used to predict the need for surfactant replacement therapy: a retrospective diagnostic accuracy study in a cohort of preterm infants. Eur J Pediatr 2023; 182:5375-5383. [PMID: 37740771 DOI: 10.1007/s00431-023-05200-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/31/2023] [Accepted: 09/06/2023] [Indexed: 09/25/2023]
Abstract
Lung ultrasound (LU) has emerged as the imaging technique of choice for the assessment of neonates with respiratory distress syndrome (RDS) at the bedside. Scoring systems were developed to quantify RDS severity and to predict the need for surfactant administration. There is no data on the comparison of the three main LU scores (LUS) proposed by Brat, Raimondi and Rodriguez-Fanjul. Moreover, there is not enough evidence to recommend which score and which cut-off has the best ability to predict surfactant need. The three LUS were compared in terms of ability to predict the need for surfactant and reproducibility in a cohort of very preterm infants. This was an observational, retrospective, multicenter study. Neonates below 32 weeks of gestational age with RDS, on non-invasive ventilation with a LU performed prior to surfactant administration (1-3 h of life) were included. Brat, Raimondi, and Rodriguez-Fanjul's scores were calculated for each patient. Receiver-operating characteristic (ROC) curve analysis was used to assess the ability to predict surfactant administration. K-Cohen test, Bland-Altman, and intraclass correlation coefficients were used to assess the intra and interobserver variability. Fifty-four preterm infants were enrolled. Brat, Raimondi, and Rodriguez-Fanjul scores showed a strong ability to predict the need for surfactant: the AUCs were 0.85 (95% CI 0.74-0.96), 0.85 (95% CI 0.75-0.96), and 0.79 (95% CI 0.67-0.92), respectively. No significant differences have been found between the AUCs using the DeLong test. Brat and Raimondi's scores had an optimal cut-off value > 8, while the Rodriguez-Fanjul's score > 10. The k-Cohen values of intraobserver agreement for Brat, Raimondi, and Rodriguez-Fanjul's scores were 0.896 (0.698-1.000), 1.000 (1.000-1.000), and 0.922 (0.767-1.000), respectively. The k-Cohen values of interobserver agreement were 0.896 (0.698-1.000), 0.911 (0.741-1.000), and 0.833 (0.612-1.000), respectively.Conclusions: The three LUS had an excellent ability to predict the need for surfactant and an optimal intra and interobserver agreement. The differences found between the three scores are minimal with negligible clinical implications. Since the optimal cut-off value differed, the same score should be used consistently within the same center. What is Known: • Lung ultrasound is a useful bedside imaging tool that should be used in the assessment of neonates with RDS • Scoring systems or lung ultrasound scores allow to quantify the severity of the pulmonary disease and to predict the need for surfactant replacement therapy What is New: • The three lung ultrasound scores by Brat, Raimondi and Rodriguez-Fanjul have an excellent ability to predict the need for surfactant replacement therapy, although with different cut-off values • All three lung ultrasound scores had an excellent intra and interobserver reproducibility.
Collapse
Affiliation(s)
- Iuri Corsini
- Neonatal Intensive Care Unit, Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy.
| | - Maria Beatrice Lenzi
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Martina Ciarcià
- Neonatal Intensive Care Unit, Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Federico Matina
- Neonatal Intensive Care Unit, Hospital Cervello Palermo, Palermo, Italy
| | - Enrico Petoello
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Alice Iride Flore
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Silvia Nogara
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| | - Antonella Gangemi
- Neonatal Intensive Care Unit, Hospital Cervello Palermo, Palermo, Italy
| | - Monica Fusco
- Neonatal Intensive Care Unit, Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Letizia Capasso
- Division of Neonatology, Department of Translational Medical Sciences, Università Federico II di Napoli, Naples, Italy
| | - Francesco Raimondi
- Division of Neonatology, Department of Translational Medical Sciences, Università Federico II di Napoli, Naples, Italy
| | - Javier Rodriguez-Fanjul
- Neonatology Department, Institut d'Investigació Germans Trias i Pujol (IGTP), Hospital Germans Trias i Pujol, Universitat Autonoma de Barcelona, Badalona, Spain
| | - Carlo Dani
- Neonatal Intensive Care Unit, Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
- Department of Neurosciences, Drug Research and Child Health, University of Florence, PsychologyFlorence, Italy
| | - Benjamim Ficial
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata Verona, Verona, Italy
| |
Collapse
|
4
|
Corsini I, Rodriguez-Fanjul J, Raimondi F, Boni L, Berardi A, Aldecoa-Bilbao V, Alonso-Ojembarrena A, Ancora G, Aversa S, Beghini R, Meseguer NB, Capasso L, Chesi F, Ciarcià M, Concheiro A, Corvaglia L, Ficial B, Filippi L, Carballal JF, Fusco M, Gatto S, Ginovart G, Gregorio-Hernández R, Lista G, Sánchez-Luna M, Martini S, Massenzi L, Miselli F, Mercadante D, Mosca F, Palacio MT, Perri A, Piano F, Prieto MP, Fernandez LR, Risso FM, Savoia M, Staffler A, Vento G, Dani C. Lung UltrasouNd Guided surfactant therapy in preterm infants: an international multicenter randomized control trial (LUNG study). Trials 2023; 24:706. [PMID: 37925512 PMCID: PMC10625281 DOI: 10.1186/s13063-023-07745-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 10/24/2023] [Indexed: 11/06/2023] Open
Abstract
BACKGROUND The management of respiratory distress syndrome (RDS) in premature newborns is based on different types of non-invasive respiratory support and on surfactant replacement therapy (SRT) to avoid mechanical ventilation as it may eventually result in lung damage. European guidelines currently recommend SRT only when the fraction of inspired oxygen (FiO2) exceeds 0.30. The literature describes that early SRT decreases the risk of bronchopulmonary dysplasia (BPD) and mortality. Lung ultrasound score (LUS) in preterm infants affected by RDS has proven to be able to predict the need for SRT and different single-center studies have shown that LUS may increase the proportion of infants that received early SRT. Therefore, the aim of this study is to determine if the use of LUS as a decision tool for SRT in preterm infants affected by RDS allows for the reduction of the incidence of BPD or death in the study group. METHODS/DESIGN In this study, 668 spontaneously-breathing preterm infants, born at 25+0 to 29+6 weeks' gestation, in nasal continuous positive airway pressure (nCPAP) will be randomized to receive SRT only when the FiO2 cut-off exceeds 0.3 (control group) or if the LUS score is higher than 8 or the FiO2 requirements exceed 0.3 (study group) (334 infants per arm). The primary outcome will be the difference in proportion of infants with BPD or death in the study group managed compared to the control group. DISCUSSION Based on previous published studies, it seems that LUS may decrease the time to administer surfactant therapy. It is known that early surfactant administration decreases BPD and mortality. Therefore, there is rationale for hypothesizing a reduction in BPD or death in the group of patients in which the decision to administer exogenous surfactant is based on lung ultrasound scores. TRIAL REGISTRATION ClinicalTrials.gov identifier NCT05198375 . Registered on 20 January 2022.
Collapse
Affiliation(s)
- Iuri Corsini
- Division of Neonatology, Careggi University Hospital of Florence, Largo Brambilla 3, 50134, Florence, Italy.
| | | | - Francesco Raimondi
- Division of Neonatology, Federico II University of Naples, Naples, Italy
| | - Luca Boni
- SC Epidemiologia Clinica IRCCS Ospedale Policlinico San Martino, Genoa, Italy
| | - Alberto Berardi
- Neonatal Intensive Care Unit, Policlinico Universitario Modena, Modena, Italy
| | - Victoria Aldecoa-Bilbao
- Neonatal Intensive Care Unit, Hospital Clínic Barcelona, BCNatal (Barcelona Center for Maternal Fetal and Neonatal Medicine), Barcelona, Spain
| | | | - Gina Ancora
- Neonatal Intensive Care Unit, Ospedale Infermi Di Rimini, Rimini, Italy
| | - Salvatore Aversa
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili, Brescia, Italy
| | - Renzo Beghini
- Neonatal Intensive Care Unit, AOUI Verona, Verona, Italy
| | | | - Letizia Capasso
- Division of Neonatology, Federico II University of Naples, Naples, Italy
| | - Francesca Chesi
- Neonatal Intensive Care Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Martina Ciarcià
- Division of Neonatology, Careggi University Hospital of Florence, Largo Brambilla 3, 50134, Florence, Italy
| | - Ana Concheiro
- Neonatal Intensive Care Unit, Hospital Alvaro Cunqueiro, Vigo, Spain
| | - Luigi Corvaglia
- Neonatal Intensive Care Unit IRCCS AUOBO, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | | | - Luca Filippi
- Neonatal Intensive Care Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
| | - Jesus Fuentes Carballal
- Neonatal Intensive Care Unit, Complexo Hospitalario Universitario de A Coruña (CHUAC), Coruña, Spain
| | - Monica Fusco
- Division of Neonatology, Careggi University Hospital of Florence, Largo Brambilla 3, 50134, Florence, Italy
| | - Sara Gatto
- Neonatal Intensive Care Unit, Ospedale Dei Bambini "V.Buzzi", Milan, Italy
| | - Gemma Ginovart
- Neonatal Intensive Care Unit. Hospital Germans Trias I Pujol, Badalona, Spain
| | | | - Gianluca Lista
- Neonatal Intensive Care Unit, Ospedale Dei Bambini "V.Buzzi", Milan, Italy
| | | | - Silvia Martini
- Neonatal Intensive Care Unit IRCCS AUOBO, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | | | - Francesca Miselli
- Neonatal Intensive Care Unit, Policlinico Universitario Modena, Modena, Italy
| | - Domenica Mercadante
- Neonatal Intensive Care Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Fabio Mosca
- Neonatal Intensive Care Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | - Marta Teresa Palacio
- Neonatal Intensive Care Unit, Hospital Clínic Barcelona, BCNatal (Barcelona Center for Maternal Fetal and Neonatal Medicine), Barcelona, Spain
| | | | - Francesca Piano
- Neonatal Intensive Care Unit, Ospedale Infermi Di Rimini, Rimini, Italy
| | | | | | - Francesco Maria Risso
- Neonatal Intensive Care Unit, Children's Hospital, ASST Spedali Civili, Brescia, Italy
| | | | | | - Giovanni Vento
- Neonatal Intensive Care Unit, Policlinico Gemelli, Rome, Italy
| | - Carlo Dani
- Division of Neonatology, Careggi University Hospital of Florence, Largo Brambilla 3, 50134, Florence, Italy
| |
Collapse
|
5
|
Kellenberger CJ, Lovrenski J, Semple T, Caro-Domínguez P. Neonatal cardiorespiratory imaging-a multimodality state-of-the-art review. Pediatr Radiol 2023; 53:660-676. [PMID: 36138217 DOI: 10.1007/s00247-022-05504-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 07/02/2022] [Accepted: 09/01/2022] [Indexed: 10/14/2022]
Abstract
Advanced cardiorespiratory imaging of the chest with ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) plays an important role in diagnosing respiratory and cardiac conditions in neonates when radiography and echocardiography alone are not sufficient. This pictorial essay highlights the particularities, clinical indications and technical aspects of applying chest US, cardiac CT and cardiorespiratory MRI techniques specifically to neonates, summarising the first session of the European Society of Paediatric Radiology's cardiothoracic task force.
Collapse
Affiliation(s)
- Christian J Kellenberger
- Department of Diagnostic Imaging, University Children's Hospital Zürich, Zurich, Switzerland
- Children's Research Centre, University Children's Hospital Zürich, Zurich, Switzerland
| | - Jovan Lovrenski
- Radiology Department, Faculty of Medicine, University of Novi Sad and Institute for Children and Adolescents Health Care of Vojvodina, Novi Sad, Serbia
| | - Thomas Semple
- Radiology Department, Royal Brompton Hospital, London, UK
- National Heart and Lung Institute, Imperial College London, London, UK
- Centre for Paediatrics and Child Health, Imperial College London, London, UK
| | - Pablo Caro-Domínguez
- Pediatric Radiology Unit, Radiology Department, Hospital Universitario Virgen del Rocío, Avenida Manuel Siurot s/n, Seville, Spain.
| |
Collapse
|
6
|
Cardiopulmonary Ultrasound Patterns of Transient Acute Respiratory Distress of the Newborn: A Retrospective Pilot Study. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10020289. [PMID: 36832418 PMCID: PMC9955778 DOI: 10.3390/children10020289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 01/20/2023] [Accepted: 01/28/2023] [Indexed: 02/05/2023]
Abstract
Acute transient respiratory distress in the first hours of life is usually defined as transient tachypnea of the newborn (TTN). TTN is a respiratory self-limiting disorder consequent to delayed lung fluid clearance at birth. While TTN is the most common etiology of respiratory distress near term, its pathogenesis and diagnostic criteria are not well-defined. Lung ultrasound and targeted neonatal echocardiography are increasingly being used to assess critically ill infants, although their combined use to improve diagnostic precision in neonatal intensive care units has not yet been described. This retrospective pilot analysis aimed to identify possible cardiopulmonary ultrasound (CPUS) patterns in term and late preterm infants suffering from transient respiratory distress and requiring non-invasive respiratory support. After retrospectively revising CPUS images, we found seven potential sonographic phenotypes of acute neonatal respiratory distress. Up to 50% of the patients presented with signs of increased pulmonary vascular resistance, suggesting that those patients may be diagnosed with mild forms of persistent pulmonary hypertension of the newborn. Approximately 80% of the infants with a history of meconium-stained amniotic fluid displayed irregular atelectasis, indicating that they may have suffered from mild meconium aspiration syndrome. CPUS evaluation may improve accuracy in the approach to the infants presenting with transient acute respiratory distress, supporting communication with the parents and carrying important epidemiological consequences.
Collapse
|
7
|
Mohsen N, Nasef N, Ghanem M, Yeung T, Deekonda V, Ma C, Kajal D, Baczynski M, Jain A, Mohamed A. Accuracy of lung and diaphragm ultrasound in predicting successful extubation in extremely preterm infants: A prospective observational study. Pediatr Pulmonol 2023; 58:530-539. [PMID: 36324211 DOI: 10.1002/ppul.26223] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/28/2022] [Accepted: 11/01/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Chest ultrasound has emerged as a promising tool in predicting extubation readiness in adults and children, yet its utility in preterm infants is lacking. Our aim was to assess the utility of lung ultrasound severity score (LUSS) and diaphragmatic function in predicting extubation readiness in extremely preterm infants. STUDY DESIGN In this prospective cohort study, preterm infants < 28 weeks gestational age (GA) who received invasive mechanical ventilation for ≥12 h were enrolled. Chest ultrasound was performed before extubation. The primary outcome was lung ultrasound accuracy for predicting successful extubation at 3 days. Descriptive statistics and logistic regression were done using SPSS version 22. RESULTS We enrolled 45 infants, of whom 36 (80%) were successfully extubated. GA and postmenstrual age (PMA) at extubation were significantly higher in the successful group. The LUSS was significantly lower in the successful group compared to failed group (11.9 ± 3.2 vs. 19.1 ± 3.1 p < 0.001). The two groups had no statistically significant difference in diaphragmatic excursion or diaphragmatic thickness fraction. Logistic regression analysis controlling for GA and PMA at extubation showed LUSS was an independent predictor for successful extubation (odd ratio 0.46, 95% confidence interval [0.23-0.9], p = 0.02). The area under the receiver operating characteristic curve was 0.95 (p ˂ 0.001) for LUSS, and a cut-off value of ≥15 had 95% sensitivity and 85% specificity in detecting extubation failure. CONCLUSION In extremely preterm infants, lung ultrasound has good accuracy for predicting successful extubation. However, diaphragmatic measurements were not reliable predictors.
Collapse
Affiliation(s)
- Nada Mohsen
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada.,Mount Sinai Hospital, Toronto, Ontario, Canada.,Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Nehad Nasef
- Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Mohab Ghanem
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada.,Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Telford Yeung
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada.,Mount Sinai Hospital, Toronto, Ontario, Canada.,Department of Pediatrics, Windsor Regional Hospital Metropolitan campus, Windsor, Ontario, Canada
| | | | - Carmen Ma
- Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Dilkash Kajal
- Mount Sinai Hospital, Toronto, Ontario, Canada.,Joint Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada
| | | | - Amish Jain
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada.,Mount Sinai Hospital, Toronto, Ontario, Canada
| | - Adel Mohamed
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada.,Mount Sinai Hospital, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Martini S, Corsini I, Corvaglia L, Suryawanshi P, Chan B, Singh Y. A scoping review of echocardiographic and lung ultrasound biomarkers of bronchopulmonary dysplasia in preterm infants. Front Pediatr 2023; 11:1067323. [PMID: 36846161 PMCID: PMC9950276 DOI: 10.3389/fped.2023.1067323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 01/18/2023] [Indexed: 02/12/2023] Open
Abstract
Despite recent improvements in neonatal care, moderate to severe bronchopulmonary dysplasia (BPD) is still associated with high mortality and with an increased risk of developing pulmonary hypertension (PH). This scoping review provides an updated overview of echocardiographic and lung ultrasound biomarkers associated with BPD and PH, and the parameters that may prognosticate their development and severity, which could be clinically helpful to undertake preventive strategies. A literature search for published clinical studies was conducted in PubMed using MeSH terms, free-text words, and their combinations obtained through appropriate Boolean operators. It was found that the echocardiography biomarkers for BPD, and especially those assessing right ventricular function, are reflective of the high pulmonary vascular resistance and PH, indicating a strong interplay between heart and lung pathophysiology; however, early assessment (e.g., during the first 1-2 weeks of life) may not successfully predict later BPD development. Lung ultrasound indicating poor lung aeration at day 7 after birth has been reported to be highly predictive of later development of BPD at 36 weeks' postmenstrual age. Evidence of PH in BPD infants increases risk of mortality and long-term PH; hence, routine PH surveillance in all at risk preterm infants at 36 weeks, including an echocardiographic assessment, may provide useful information. Progress has been made in identifying the echocardiographic parameters on day 7 and 14 to predict later development of pulmonary hypertension. More studies on sonographic markers, and especially on echocardiographic parameters, are needed for the validation of the currently proposed parameters and the timing of assessment before recommendations can be made for the routine clinical practice.
Collapse
Affiliation(s)
- Silvia Martini
- Neonatal Intensive Care Unit, IRCCS AOUBO, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Iuri Corsini
- Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Luigi Corvaglia
- Neonatal Intensive Care Unit, IRCCS AOUBO, Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy
| | - Pradeep Suryawanshi
- Department of Neonatology, Bharati Vidyapeeth University Medical College, Pune, India
| | - Belinda Chan
- Division of Neonatology, University of Utah, Salt Lake City, UT, United States
| | - Yogen Singh
- Department of Pediatrics - Division of Neonatology, Loma Linda University School of Medicine, Loma linda, CA, United States.,Neonatology/Pediatric Cardiology, Cambridge University Hospitals, Cambridge, United Kingdom
| |
Collapse
|
9
|
Corsini I, Parri N, Ficial B, Ciarcià M, Migliaro F, Capasso L, Savoia M, Gizzi C, Clemente M, Raimondi F, Dani C. Lung ultrasound in Italian neonatal intensive care units: A national survey. Pediatr Pulmonol 2022; 57:2199-2206. [PMID: 35637553 DOI: 10.1002/ppul.26025] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/25/2022] [Accepted: 05/29/2022] [Indexed: 11/11/2022]
Abstract
INTRODUCTION Lung ultrasound (LU) is a noninvasive, bedside imaging technique that is attracting growing interest in the evaluation of neonatal respiratory diseases. We conducted a nationwide survey of LU usage in Italian neonatal intensive care units (NICUs). METHODS A structured questionnaire was developed and sent online to 114 Italian NICUs from June to September 2021. RESULTS The response rate was 79%. In the past 4 years (range: 2-6), LU has been adopted in 82% of Italian NICUs. It is the first-choice diagnostic test in 23% of the centers surveyed. The main LU diagnostic applications reported were: pneumothorax (95%), respiratory distress syndrome (89%), transient tachypnea of the newborn (89%), plural effusion (88%), atelectasis (66%), pneumonia (64%), bronchopulmonary dysplasia (43%), congenital pulmonary airway malformation (41%), and congenital diaphragmatic hernia (34%). Thirty percent of participating centers calculated LU score routinely, but only seven units used it to predict the need for surfactant replacement. Sixty-six percent of respondents learned the LU technique via a self-training process, while 34% of them visited an expert in the field for one-to-one tuition. CONCLUSIONS LU has a widespread use in Italian NICUs. However, the use of LU is extremely heterogeneous among centers. There is an urgent need to ensure standardization of clinical practice guidelines and to design and implement a formalized and accredited training program.
Collapse
Affiliation(s)
- Iuri Corsini
- Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Niccolò Parri
- Department of Emergency Medicine and Trauma Center, Meyer University Children's Hospital, Florence, Italy
| | - Benjamim Ficial
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Martina Ciarcià
- Division of Neonatology, Careggi University Hospital of Florence, Florence, Italy
| | - Fiorella Migliaro
- Division of Neonatology, Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Letizia Capasso
- Division of Neonatology, Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Marilena Savoia
- Neonatal Intensive Care Unit, S Maria della Misericordia Hospital, Udine, Italy
| | - Camilla Gizzi
- Department of Pediatrics, Sandro Pertini Hospital, ASL RM2, Rome, Italy
| | - Maria Clemente
- Neonatal Intensive Care Unit, Azienda Ospedaliera Universitaria Integrata di Verona, Verona, Italy
| | - Francesco Raimondi
- Division of Neonatology, Department of Translational Medical Sciences, University Federico II, Naples, Italy
| | - Carlo Dani
- Department of Neurosciences Psychology Drug Research and Child Health, Careggi University Hospital of Florence, Florence, Italy
| |
Collapse
|