1
|
Chai Y, Chen H, Liu X, Lu C. Degradation of the Neonicotinoid Pesticides in the Atmospheric Pressure Ionization Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:373-381. [PMID: 29260456 DOI: 10.1007/s13361-017-1832-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Revised: 10/01/2017] [Accepted: 10/01/2017] [Indexed: 05/21/2023]
Abstract
During the analysis of neonicotinoid pesticide standards (thiamethoxam, clothianidin, imidacloprid, acetamiprid, and thiacloprid) by mass spectrometry, the degradation of these pesticides (M-C=N-R is degraded into M-C=O, M is the skeleton moiety, and R is NO2 or CN) was observed in the atmospheric pressure ionization interfaces (ESI and APCI). In APCI, the degradation of all the five neonicotinoid pesticides studied took place, and the primary mechanism was in-source ion/molecule reaction, in which a molecule of water (confirmed by use of H218O) attacked the carbon of the imine group accompanying with loss of NH2R (R=NO2, CN). For the nitroguanidine neonicotinoid pesticides (R=NO2, including thiamethoxam, clothianidin, and imidacloprid), higher auxiliary gas heater temperature also contributed to their degradation in APCI due to in-source pyrolysis. The degradation of the five neonicotinoid pesticides studied in ESI was not significant. In ESI, only the nitroguanidine neonicotinoid pesticides could generate the degradation products through in-source fragmentation mechanism. The degradation of cyanoamidine neonicotinoid pesticides (R=CN, including acetamiprid and thiacloprid) in ESI was not observed. The degradation of neonicotinoid pesticides in the ion source of mass spectrometer renders some adverse consequences, such as difficulty interpreting the full-scan mass spectrum, reducing the sensitivity and accuracy of quantitative analysis, and misleading whether these pesticides have degraded in the real samples. Therefore, a clear understanding of these unusual degradation reactions should facilitate the analysis of neonicotinoid pesticides by atmospheric pressure ionization mass spectrometry. Graphical Abstract.
Collapse
Affiliation(s)
- Yunfeng Chai
- Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
- Key Laboratory of Tea Quality and Safety Control, Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
- Laboratory of Quality and Safety Risk Assessment for Tea (Hangzhou), Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
| | - Hongping Chen
- Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
- Key Laboratory of Tea Quality and Safety Control, Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
- Laboratory of Quality and Safety Risk Assessment for Tea (Hangzhou), Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China
| | - Xin Liu
- Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
- Key Laboratory of Tea Quality and Safety Control, Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
- Laboratory of Quality and Safety Risk Assessment for Tea (Hangzhou), Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
| | - Chengyin Lu
- Tea Research Institute, Chinese Academy of Agricultural Sciences, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
- Key Laboratory of Tea Quality and Safety Control, Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
- Laboratory of Quality and Safety Risk Assessment for Tea (Hangzhou), Ministry of Agriculture, 9 South Meiling Road, Hangzhou, 310008, People's Republic of China.
| |
Collapse
|
2
|
Li DX, Gan L, Bronja A, Schmitz OJ. Gas chromatography coupled to atmospheric pressure ionization mass spectrometry (GC-API-MS): Review. Anal Chim Acta 2015; 891:43-61. [DOI: 10.1016/j.aca.2015.08.002] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 07/20/2015] [Accepted: 08/02/2015] [Indexed: 10/23/2022]
|
3
|
Vaikkinen A, Rejšek J, Vrkoslav V, Kauppila TJ, Cvačka J, Kostiainen R. Feasibility of desorption atmospheric pressure photoionization and desorption electrospray ionization mass spectrometry to monitor urinary steroid metabolites during pregnancy. Anal Chim Acta 2015; 880:84-92. [DOI: 10.1016/j.aca.2015.03.029] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Revised: 03/17/2015] [Accepted: 03/20/2015] [Indexed: 01/27/2023]
|
4
|
Application of a novel metabolomic approach based on atmospheric pressure photoionization mass spectrometry using flow injection analysis for the study of Alzheimer׳s disease. Talanta 2015; 131:480-9. [DOI: 10.1016/j.talanta.2014.07.075] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2014] [Revised: 07/21/2014] [Accepted: 07/25/2014] [Indexed: 12/14/2022]
|
5
|
Analysis of anabolic steroids in urine by gas chromatography–microchip atmospheric pressure photoionization-mass spectrometry with chlorobenzene as dopant. J Chromatogr A 2013; 1312:111-7. [DOI: 10.1016/j.chroma.2013.08.098] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Revised: 08/01/2013] [Accepted: 08/29/2013] [Indexed: 01/25/2023]
|
6
|
Feasibility of gas chromatography–microchip atmospheric pressure photoionization-mass spectrometry in analysis of anabolic steroids. J Chromatogr A 2010; 1217:8290-7. [DOI: 10.1016/j.chroma.2010.10.074] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Revised: 09/13/2010] [Accepted: 10/18/2010] [Indexed: 12/14/2022]
|
7
|
Patti GJ, Woo HK, Yanes O, Shriver L, Thomas D, Uritboonthai W, Apon JV, Steenwyk R, Manchester M, Siuzdak G. Detection of carbohydrates and steroids by cation-enhanced nanostructure-initiator mass spectrometry (NIMS) for biofluid analysis and tissue imaging. Anal Chem 2010; 82:121-8. [PMID: 19961200 DOI: 10.1021/ac9014353] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Nanostructure-initiator mass spectrometry (NIMS) is a highly sensitive, matrix-free technique that is well suited for biofluid analysis and imaging of biological tissues. Here we provide a new technical variation of NIMS to analyze carbohydrates and steroids, molecules that are challenging to detect with traditional mass spectrometric approaches. Analysis of carbohydrates and steroids was accomplished by spray depositing NaCl or AgNO(3) on the NIMS porous silicon surface to provide a uniform environment rich with cationization agents prior to desorption of the fluorinated polymer initiator. Laser desorption/ionization of the ion-coated NIMS surface allowed for Na(+) cationization of carbohydrates and Ag(+) cationization of steroids. The reliability of the approach is quantitatively demonstrated with a calibration curve over the physiological range of glucose and cholesterol concentrations in human serum (1-200 microM). Additionally, we illustrate the sensitivity of the method by showing its ability to detect carbohydrates and steroids down to the 800-amol and 100-fmol levels, respectively. The technique developed is well suited for tissue imaging of biologically significant metabolites such as sucrose and cholesterol. To highlight its applicability, we used cation-enhanced NIMS to image the distribution of sucrose in a Gerbera jamesonii flower stem and the distribution of cholesterol in a mouse brain. The flower stem and brain sections were placed directly on the ion-coated NIMS surface without further preparation and analyzed directly. The overall results reported underscore the potential of NIMS to analyze and image chemically diverse compounds that have been traditionally challenging to observe with mass spectrometry-based techniques.
Collapse
Affiliation(s)
- Gary J Patti
- Department of Molecular Biology, Scripps Center for Mass Spectrometry, The Scripps Research Institute, 10550 North Torrey Pines Road, La Jolla, California 92037, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Nagy L, Pálfi V, Narmandakh M, Kuki A, Nyíri A, Iván B, Zsuga M, Kéki S. Dopant-assisted atmospheric pressure photoionization mass spectrometry of polyisobutylene derivatives initiated by mono- and bifunctional initiators. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:2342-2351. [PMID: 19819723 DOI: 10.1016/j.jasms.2009.08.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2009] [Revised: 08/28/2009] [Accepted: 08/30/2009] [Indexed: 05/28/2023]
Abstract
Nine polyisobutylene (PIB) derivatives with different end groups (chlorine, vinyl, isobutenyl, 2,2-diphenylvinyl, and carboxyl) and molecular weights (1000 to 4500 g/mol), initiated by monofunctional and aromatic bifunctional initiators were studied by atmospheric pressure photoionization mass spectrometry (APPI-MS) in both negative and positive ion modes. Consistent with previous findings, negative ion APPI-MS revealed end-group identities through the formation of PIB adducts with chloride ions formed in situ from a chlorinated solvent (e.g., CCl4) in the presence of a dopant (toluene). In positive ion mode, considerable fragmentation of these PIB derivatives was observed, rendering end-group determinations very difficult. The M(n) values obtained by APPI(-)-MS were considerably lower than those determined by SEC for PIB derivatives with M(n) higher than 2000 g/mol. PIBs containing carboxyl termini can undergo collision-induced dissociation, yielding structurally important product ions. The resulting APPI-MS/MS intensities were found to reflect the "arm-length" distribution for PIBs with bifunctional aromatic moieties. In positive ion mode, [M + COCl]+ adducts were observed for PIBs with an aromatic initiator moiety. The origin of the COCl+ species is also discussed.
Collapse
Affiliation(s)
- Lajos Nagy
- Department of Applied Chemistry, University of Debrecen, Debrecen, Hungary
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Development and validation of a liquid chromatography–atmospheric pressure photoionization–mass spectrometry method for the quantification of alprazolam, flunitrazepam, and their main metabolites in haemolysed blood. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:2275-83. [DOI: 10.1016/j.jchromb.2008.12.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2008] [Revised: 11/28/2008] [Accepted: 12/01/2008] [Indexed: 11/20/2022]
|
10
|
Pan Y, Zhang LD, Guo HJ, Yin H, Qi F. Photoionization and Dissociative Photoionization Study of Cholesterol by IR Laser Desorption/Tunable Synchrotron VUV Photoionization Mass Spectrometry. CHINESE J CHEM PHYS 2009. [DOI: 10.1088/1674-0068/22/02/129-133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Rodil R, Schrader S, Moeder M. Comparison of atmospheric pressure photoionization and electrospray ionization mass spectrometry for the analysis of UV filters. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:580-588. [PMID: 19165778 DOI: 10.1002/rcm.3910] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
A comparison was made between the electrospray ionization (ESI) and atmospheric pressure photoionization (APPI) tandem mass spectrometric (MS/MS) responses of eleven ultraviolet (UV) filters. Four of the target compounds were favourably ionized in negative ion mode, and the other seven compounds in positive ion mode. For nine of the compounds APPI generated a similar response to that of ESI, but the APPI signal-to-noise (S/N) ratios were 1.3-60 times higher. The two most polar of the UV filter compounds (PBSA and BP-4) were more efficiently ionized by ESI, offering higher signal intensities and lower detection limits. APPI was, however, less susceptible to ion suppression than ESI when real samples were injected. In order to optimize the APPI conditions different dopant solvents were examined to enhance the efficiency of the photoionization process. Among the evaluated dopants, toluene was selected as the best compromise. At a toluene flow rate of 10% of the solvent flow rates the ionization response increased by a factor of 40-50 over the use of no dopant for the compounds in positive ion mode and by more than 300 for the compounds in negative ion mode.
Collapse
Affiliation(s)
- Rosario Rodil
- Department of Analytical Chemistry, University of A Coruña, Campus da Zapateira, 15071-A Coruña, Spain.
| | | | | |
Collapse
|
12
|
Schappler J, Guillarme D, Prat J, Veuthey JL, Rudaz S. Coupling CE with atmospheric pressure photoionization MS for pharmaceutical basic compounds: Optimization of operating parameters. Electrophoresis 2007; 28:3078-87. [PMID: 17724698 DOI: 10.1002/elps.200700012] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The use of CE coupled with MS (CE-MS) has evolved as a useful tool to analyze charged species in small sample volumes. Because of its sensitivity, versatility and ease of implementation, the ESI interface is currently the method of choice to hyphenate CE to MS. An alternative can be the atmospheric pressure photoionization (APPI) source, however, numerous parameters must be optimized for its coupling to CE. After evaluation of the sheath liquid composition and the CE capillary outlet position, an experimental design methodology was assessed for optimizing other ionization source parameters, such as sheath liquid flow rate, drying gas flow rate and temperature, nebulizing gas pressure, vaporizer temperature, and capillary voltage. For this purpose, a fractional factorial design (FFD) was selected as a screening procedure to identify factors which significantly influence sensitivity and efficiency. A face-centered central composite design (CCD) was then used to predict and optimize sensitivity, taking into account the most relevant variables. Sensitivity was finally evaluated with the optimized conditions and height-to-noise ratios (H/N) around 10 were achieved for an injection of 200 ng/mL of each analyte.
Collapse
Affiliation(s)
- Julie Schappler
- Laboratory of Analytical Pharmaceutical Chemistry, School of Pharmaceutical Sciences, EPGL, University of Geneva, University of Lausanne, Geneva, Switzerland
| | | | | | | | | |
Collapse
|
13
|
Gentili A. LC-MS methods for analyzing anti-inflammatory drugs in animal-food products. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2007.01.013] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Hommerson P, Khan AM, de Jong GJ, Somsen GW. Comparison of atmospheric pressure photoionization and ESI for CZE-MS of drugs. Electrophoresis 2007; 28:1444-53. [PMID: 17351894 DOI: 10.1002/elps.200600504] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The performance of atmospheric pressure photoionization (APPI) and ESI for CZE was compared using a set of seven drugs (basic amines, quaternary amines and steroids) and four different BGEs. The influence of volatile and nonvolatile BGEs of acidic and neutral pH on the MS responses of test compounds was evaluated by infusion of test solutions into the respective ion sources, and by actual CZE-MS experiments. The infusion experiments indicate that sodium phosphate buffers cause ionization suppression in ESI-MS, although for the amines the suppression was modest (25-60% signal reduction). By contrast, APPI-MS responses were not affected by nonvolatile BGEs. With phosphate buffers, ESI-MS responses for the basic amines were still a factor 3-13 higher than the APPI-MS signals, whereas the steroids yielded similar responses in ESI-MS and APPI-MS. The quaternary amines could readily be detected in ESI-MS, but detection in APPI-MS required specific interface conditions. Using typical CZE-APPI-MS settings, quaternary amines remained undetected. Remarkably, the S/Ns observed in CZE-ESI-MS for the test compounds, were generally similar when using volatile and nonvolatile BGEs. For basic compounds, the S/Ns obtained in CZE-ESI-MS were a factor 2-5 higher than in CZE-APPI-MS, whereas steroids yielded equal S/Ns in both methods. Overall, it is concluded that when using relatively low BGE concentrations, the sensitivity of ESI-MS detection in CZE is more favorable than APPI-MS detection, even when nonvolatile BGEs are employed.
Collapse
Affiliation(s)
- Paul Hommerson
- Department of Biomedical Analysis, Utrecht University, Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
15
|
Short LC, Cai SS, Syage JA. APPI-MS: effects of mobile phases and VUV lamps on the detection of PAH compounds. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2007; 18:589-99. [PMID: 17188507 PMCID: PMC2709839 DOI: 10.1016/j.jasms.2006.11.004] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2006] [Revised: 11/02/2006] [Accepted: 11/03/2006] [Indexed: 05/13/2023]
Abstract
The technique of atmospheric pressure photoionization (APPI) has several advantages over electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), including efficient ionization of nonpolar or low charge affinity compounds, reduced susceptibility to ion suppression, high sensitivity, and large linear dynamic range. These benefits are greatest at low flow rates (i.e.,
Collapse
|
16
|
Short LC, Hanold KA, Cai SS, Syage JA. Electrospray ionization/atmospheric pressure photoionization multimode source for low-flow liquid chromatography/mass spectrometric analysis. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:1561-6. [PMID: 17428016 DOI: 10.1002/rcm.2999] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Analysis of several polar and non-polar compounds is performed with a newly developed dual electrospray ionization/atmospheric pressure photoionization (ESI/APPI) or ESPI source. Several variables are considered in the source, such as ESI probe heater temperature, solvent flow, dopant effects, repeller plate voltage, source geometry and photon energy (Kr vs. Ar lamp). Direct photoionization resulting in a molecular radical cation [M](*+) dominates at high temperatures (>400 degrees C) and low flow rates (<200 microL/min). Indirect photo-induced chemical ionization (PCI) involving solvent molecules becomes important at lower temperatures and higher solvent flow rates. Indirect PCI is enhanced using an Ar lamp, which yields comparable [M+H](+) signal but poorer [M](*+) signal than the Kr lamp at lower temperatures and higher flow rates. This is in support of our recent finding that the Ar lamp results in a solvent-dependent enhancement of analyte molecules via PCI. Analysis of 12 compounds in methanol under low-flow conditions (10 microL/min) demonstrates that the dual ESPI source performs favorably for most compounds versus the standard ESCI source, and significantly better than ESCI for the analysis of unstable drugs, like flurbiprofen. Several factors contributing to the benefits of the ESPI source are the shared optimal geometry for ESI and APPI sources and soft ionization of APPI versus APCI.
Collapse
Affiliation(s)
- Luke C Short
- Syagen Technology, Inc., 1411 Warner Ave Suite D, Tustin, CA 92780-6461, USA
| | | | | | | |
Collapse
|
17
|
Zheng J, Shamsi SA. Capillary Electrochromatography Coupled to Atmospheric Pressure Photoionization Mass Spectrometry for Methylated Benzo[a]pyrene Isomers. Anal Chem 2006; 78:6921-7. [PMID: 17007515 DOI: 10.1021/ac061024c] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Benzo[a]pyrene, one of the most carcinogenic PAHs, has 12 monomethylated positional isomers (MBAPs). A strong correlation between the carcinogenicity of these isomers and methyl substitution has been reported. In this study, on-line coupling of capillary electrochromatography (CEC) and atmospheric pressure photoionization mass spectrometry (APPI-MS) provides a unique solution to highly selective separation and sensitive detection of MBAP isomers. The studies indicated that APPI provides significantly better sensitivity compared to electrospray ionization and atmospheric pressure chemical ionization modes of MS. A systematic investigation of APPI-MS detection parameters and CEC separation is established. First, several sheath liquid parameters (including type and concentration of volatile buffers, type and content of organic modifiers, use of dopants and inorganic/organic additives, and sheath liquid flow rate) and APPI-MS spray chamber parameters (capillary voltage, vaporizer temperature, nebulizer pressure) were found to have effects on detection sensitivity as well as the profile of mass spectrum. For example, when ammonium acetate was replaced with acetic acid in the sheath liquid, the MS signal was enhanced as much as 90% and the formation of ammonia adduct was effectively suppressed. Next, the separation of MBAP isomers was conducted on internal tapered columns packed with polymeric C18 stationary phase. With the use of a mobile phase consisting of slightly higher acetonitrile content (90%,v/v) and a small amount of tropylium ion, the analysis times were significantly shortened by 20 min without compromising the resolutions between the isomers. Finally, quantitative aspects of the CEC-APPI-MS method were demonstrated using 7-MBAP as the internal standard. The calibration curves of three of the most carcinogenic isomers, namely, 1-MBAP, 3-MBAP, and 11-MBAP, showed good linearity in the range of 2.5-50 microg/mL with a limit of detection at 400 ng/mL.
Collapse
Affiliation(s)
- Jie Zheng
- Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, Georgia 30303, USA
| | | |
Collapse
|
18
|
Purcell JM, Hendrickson CL, Rodgers RP, Marshall AG. Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for Complex Mixture Analysis. Anal Chem 2006; 78:5906-12. [PMID: 16906739 DOI: 10.1021/ac060754h] [Citation(s) in RCA: 222] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We have coupled atmospheric pressure photoionization (APPI) to a home-built 9.4-T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Analysis of naphtho[2,3-a]pyrene and crude oil mass spectra reveals that protonated molecules, deprotonated molecules, and radical molecular ions are formed simultaneously in the ion source, thereby complicating the spectra (>12 000 peaks per mass spectrum and up to 63 peaks of the same nominal mass), and eliminating the "nitrogen rule" for nominal mass determination of number of nitrogens. Nevertheless, the ultrahigh mass resolving power and mass accuracy of FT-ICR MS enable definitive elemental composition assignments, even for doublets as closely spaced as 1.1 mDa (SH3(13)C vs (12)C4). APPI efficiently ionizes nonpolar compounds that are unobservable by electrospray and allows nonpolar sulfur speciation of petrochemical mixtures.
Collapse
Affiliation(s)
- Jeremiah M Purcell
- National High Magnetic Field Laboratory, Florida State University, 1800 East Paul Dirac Drive, Tallahassee, Florida 32310-4005, USA
| | | | | | | |
Collapse
|
19
|
Kauppila TJ, Nikkola T, Ketola RA, Kostiainen R. Atmospheric pressure photoionization-mass spectrometry and atmospheric pressure chemical ionization-mass spectrometry of neurotransmitters. JOURNAL OF MASS SPECTROMETRY : JMS 2006; 41:781-9. [PMID: 16705666 DOI: 10.1002/jms.1034] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
A group of five neurotransmitters with different properties was analyzed using atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization-mass spectrometry (APCI-MS). The sensitivity of the techniques for the analytes was tested in six solvents and in positive and negative ion modes. APPI was found to be superior in sensitivity for all the compounds in both positive and negative ion modes. In positive ion mode, water/methanol/formic acid was found to be the best solvent, whereas in negative ion mode, water/methanol/ammonium hydroxide performed best. Detection limits using APPI were between 2.5-250 fmol, depending on the compound. The sensitivity was best for the neurosteroids dehydroepiandrosterone and beta-estradiol, and acetylcholine (LOD 2.5-10 fmol).
Collapse
Affiliation(s)
- T J Kauppila
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Helsinki, FIN-00014 Helsinki, Finland
| | | | | | | |
Collapse
|
20
|
Cai SS, Syage JA. Atmospheric pressure photoionization mass spectrometry for analysis of fatty acid and acylglycerol lipids. J Chromatogr A 2006; 1110:15-26. [PMID: 16472815 DOI: 10.1016/j.chroma.2006.01.050] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2005] [Revised: 01/05/2006] [Accepted: 01/11/2006] [Indexed: 11/24/2022]
Abstract
In this work, we optimize parameters and conditions for analysis of fatty acid ester and acylglycerol lipids by atmospheric pressure photoionization-mass spectrometry (APPI-MS). The investigated parameters include atmospheric pressure chemical ionization (APCI) nebulizer/vaporizer physical orientation and APPI lamp face position, solvent selections, mobile phase compositions and flow rates, cone voltages and probe temperatures. APPI sensitivity is found to be highly dependent on mobile phase compositions. Normal phase solvents offer much higher sensitivity and better peak shape than reversed phase for nonpolar lipids. Hexane and isooctane are found to be two solvents generating highest S/N for eicosapentaenoic acid (EPA) methyl ester. The effects of mobile phase flow rates on sensitivity are found to be target analytes and target ions specific. However, the flow rate changes do not significantly affect the sensitivity of three out of four tested analytes under normal phase conditions over tested flow rates of 50-500muL/min. Cone voltage is found to be one of key parameters affecting sensitivity. Optimum probe temperature is found to be more dependent on mobile phase compositions than on the specific target analytes. Aqueous reversed-phase mobile phase requires higher probe temperature than normal phase for better sensitivity. More volatile mobile phase solvents require lower probe temperature for analyte desolvation. APPI offers four to five decades of linear ranges under normal phase condition. Full scan mass spectra of individual lipid standards, custom lipid mixtures and natural fish oil show that APPI spectra are clean and very easy to interpret. APPI also gives stable, reproducible peak responses with good peak shape. Limits of detection (LODs) by FIA (S/N=3) are estimated to be 12pg for EPA methyl ester and monoarachidin, 19pg for diarachidin and 7pg for trielaidin. LODs on-column are estimated to be 94pg for EPA methyl ester, 90pg for monoarachidin and diarachidin and 24pg for trielaidin.
Collapse
Affiliation(s)
- Sheng-Suan Cai
- Syagen Technology, Inc., 1411 Warner Ave., Tustin, CA 92780, USA
| | | |
Collapse
|
21
|
Cai SS, Syage JA. Comparison of Atmospheric Pressure Photoionization, Atmospheric Pressure Chemical Ionization, and Electrospray Ionization Mass Spectrometry for Analysis of Lipids. Anal Chem 2006; 78:1191-9. [PMID: 16478111 DOI: 10.1021/ac0515834] [Citation(s) in RCA: 142] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In this work, we compare the quantitative accuracy and sensitivity of analyzing lipids by atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) LC/MS. The target analytes include free fatty acids and their esters, monoglyceride, diglyceride, and triglyceride. The results demonstrate the benefits of using LC/APPI-MS for lipid analysis. Analyses were performed on a Waters ZQ LC/MS. Normal-phase solvent systems were used due to low solubility of these compounds in aqueous reversed-phase solvent systems. By comparison, APPI offers lower detection limits, generally highest signal intensities, and the highest S/N ratio. APPI is 2-4 times more sensitive than APCI and much more sensitive than ESI without mobile-phase modifiers. APPI and APCI offer comparable linear range (i.e., 4-5 decades). ESI sensitivity is dramatically enhanced by use of mobile phase modifiers (i.e., ammonium formate or sodium acetate); however, these ESI adduct signals are less stable and either are nonlinear or have dramatically reduced linear ranges. Analysis of fish oils by APPI shows significantly enhanced target analyte intensities in comparison with APCI and ESI.
Collapse
Affiliation(s)
- Sheng-Suan Cai
- Syagen Technology Inc., 1411 Warner Avenue, Tustin, CA 92780, USA
| | | |
Collapse
|
22
|
Wang Y, Hornshaw M, Alvelius G, Bodin K, Liu S, Sjövall J, Griffiths WJ. Matrix-assisted laser desorption/ionization high-energy collision-induced dissociation of steroids: analysis of oxysterols in rat brain. Anal Chem 2006; 78:164-73. [PMID: 16383324 PMCID: PMC2315783 DOI: 10.1021/ac051461b] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Neutral steroids have traditionally been analyzed by gas chromatography/mass spectrometry (GC/MS) after necessary derivatization reactions. However, GC/MS is unsuitable for the analysis of many conjugated steroids and those with unsuspected functional groups. Here we describe an alternative analytical method specifically designed for the analysis of oxosteroids and those with a 3beta-hydroxy-delta5 or 5alpha-hydrogen-3beta-hydroxy structure. Steroids were derivatized with Girard P (GP) hydrazine to give GP hydrazones, which are charged species and readily analyzed by matrix-assisted laser desorption/ionization mass spectrometry. The resulting [M]+ ions were then subjected to high-energy collision-induced dissociation on a tandem time-of-flight instrument. The product ion spectra give structurally informative fragment ion patterns. The sensitivity of the analytical method is such that steroid structures can be determined from low-picogram (low-femtomole) amounts of sample. The utility of the method has been demonstrated by the analysis of oxysterols extracted from rat brain.
Collapse
Affiliation(s)
- Yuqin Wang
- The School of Pharmacy, University of London, 29/39 Brunswick Square, London WC1N 1AX, UK
| | | | - Gunvor Alvelius
- Department of Medical Biochemistry & Biophysics, Karolinska Institutet, Stockholm SE 171 77, Sweden
| | - Karl Bodin
- Department of Medical Biochemistry & Biophysics, Karolinska Institutet, Stockholm SE 171 77, Sweden
| | - Suya Liu
- Department of Medical Biochemistry & Biophysics, Karolinska Institutet, Stockholm SE 171 77, Sweden
| | - Jan Sjövall
- Department of Medical Biochemistry & Biophysics, Karolinska Institutet, Stockholm SE 171 77, Sweden
| | - William J. Griffiths
- The School of Pharmacy, University of London, 29/39 Brunswick Square, London WC1N 1AX, UK
| |
Collapse
|
23
|
Bos SJ, van Leeuwen SM, Karst U. From fundamentals to applications: recent developments in atmospheric pressure photoionization mass spectrometry. Anal Bioanal Chem 2005; 384:85-99. [PMID: 16456932 DOI: 10.1007/s00216-005-0046-1] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Only five years after the first publication on atmospheric pressure photoionization (APPI), this technique has evolved rapidly as a very useful complement to established ionization techniques for liquid chromatography/mass spectrometry (LC/MS). This is reflected in a rapidly increasing number of publications in this field. On the one hand, thorough studies into the photoionization mechanism have provided deep insights into the roles and influences of the solvent, the dopant and other additives. On the other hand, a large number of new and attractive applications have recently been introduced. New instrumental developments have resulted in combined APPI/ESI (PAESI) and APPI/APCI sources and a microfabricated APPI source. In this review, the most important developments within the field are summarized, focusing in particular on the applications of the technique.
Collapse
Affiliation(s)
- Suzanne J Bos
- Chemical Analysis Group and MESA+ Institute for Nanotechnology, University of Twente, Enschede, The Netherlands
| | | | | |
Collapse
|
24
|
Zhang J, McCombie G, Guenat C, Knochenmuss R. FT-ICR mass spectrometry in the drug discovery process. Drug Discov Today 2005; 10:635-42. [PMID: 15894228 DOI: 10.1016/s1359-6446(05)03438-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The high mass accuracy and resolution of Fourier transform (FT)-ion cyclotron resonance (ICR) mass spectrometry are making it an increasingly useful tool in drug discovery and development. The basics of FT-ICR are described here, including modern ion sources and fragmentation methods. Although FT-ICR is not a high-throughput method in the traditional sense, previously difficult and complex problems are being efficiently approached using steadily improving instruments and magnets. Applications are surveyed in fields such as proteomics, metabonomics, natural product analysis and non-covalent complexes.
Collapse
Affiliation(s)
- Juan Zhang
- Novartis Institutes for Biomedical Research, Lichtstrasse 35, CH 4056 Basel, Switzerland
| | | | | | | |
Collapse
|
25
|
Trösken ER, Straube E, Lutz WK, Völkel W, Patten C. Quantitation of lanosterol and its major metabolite FF-MAS in an inhibition assay of CYP51 by azoles with atmospheric pressure photoionization based LC-MS/MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2004; 15:1216-1221. [PMID: 15276168 DOI: 10.1016/j.jasms.2004.04.036] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2004] [Revised: 04/29/2004] [Accepted: 04/29/2004] [Indexed: 05/24/2023]
Abstract
Azoles affect the steroid balance in all biological systems and may therefore be called endocrine disrupters. Lanosterol 14alpha-demethylase (CYP51) is an enzyme inhibited by azoles. Only few data have been reported showing their inhibitory potency since an assay in an in vitro system is not available so far. In the present work an inhibition assay using human recombinant CYP51, coexpressed with human P450 oxido-reductase by the baculovirus/insect cell expression system, and LC-MS/MS as analytical method is described. Atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were used with a triple quadrupole mass spectrometer to compare quantitation of lanosterol (substrate) and 4,4-dimethyl-5alpha-cholesta-8,14,24-triene-3beta-ol (FF-MAS) (product of CYP51) with d(6)-2,2,3,4,4,6-cholesterol (d(6)-cholesterol) as internal standard. Optimization of analytical parameters resulted in a LC-APPI-MS/MS method with a LOQ of 10 pg on column for FF-MAS. The sensitivity of the method (LOD 0.5 ng/ml) makes it possible to analyze supernatants of inhibition experiments after precipitation of proteins by isopropanol without any sample enrichment. The coefficient of variation of the analytical method was <20% (n = 5) for FF-MAS, lanosterol and d(6)-cholesterol. The external calibration curve was linear from 1 to 10,000 ng/ml with R(2) >/= 0.999 and an accuracy of 94-115%. Compared with APCI, APPI provides a ten- to 500-fold increase in sensitivity for the analytes in this study. IC(50) values of epoxiconazole and miconazole-two widely used azole fungicides used in agriculture and in human medicine, respectively-were 1.95 microM and 0.057 microM.
Collapse
Affiliation(s)
- Eva R Trösken
- Department of Toxicology, University of Würzburg, Würzburg, Germany
| | | | | | | | | |
Collapse
|