1
|
Salek M, Förster JD, Lehmann WD, Riemer AB. Light contamination in stable isotope-labelled internal peptide standards is frequent and a potential source of false discovery and quantitation error in proteomics. Anal Bioanal Chem 2022; 414:2545-2552. [PMID: 35119480 PMCID: PMC8888373 DOI: 10.1007/s00216-022-03931-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/22/2021] [Accepted: 01/26/2022] [Indexed: 11/12/2022]
Abstract
In mass spectrometry-based proteomics, heavy internal standards are used to validate target peptide detections and to calibrate peptide quantitation. Here, we report light contamination present in heavy labelled synthetic peptides of high isotopic enrichment. Application of such peptides as assay-internal standards potentially compromises the detection and quantitation especially of low abundant cellular peptides. Therefore, it is important to adopt guidelines to prevent false-positive identifications of endogenous light peptides as well as errors in their quantitation from biological samples.
Collapse
Affiliation(s)
- Mogjiborahman Salek
- Immunotherapy & Immunoprevention, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
- Molecular Vaccine Design, German Center for Infection Research (DZIF), Partner Site Heidelberg, Heidelberg, Germany.
| | - Jonas D Förster
- Immunotherapy & Immunoprevention, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
- Molecular Vaccine Design, German Center for Infection Research (DZIF), Partner Site Heidelberg, Heidelberg, Germany
- Faculty of Biosciences, Heidelberg University, Heidelberg, Germany
| | - Wolf-Dieter Lehmann
- Molecular Structure Analysis, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Angelika B Riemer
- Immunotherapy & Immunoprevention, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
- Molecular Vaccine Design, German Center for Infection Research (DZIF), Partner Site Heidelberg, Heidelberg, Germany.
| |
Collapse
|
2
|
Nasiri A, Jahani R, Mokhtari S, Yazdanpanah H, Daraei B, Faizi M, Kobarfard F. Overview, consequences, and strategies for overcoming matrix effects in LC-MS analysis: a critical review. Analyst 2021; 146:6049-6063. [PMID: 34546235 DOI: 10.1039/d1an01047f] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
The high-performance liquid chromatography-mass spectrometry (LC-MS) technique is widely applied to routine analysis in many matrices. Despite the enormous application of LC/MS, this technique is subjected to drawbacks called matrix effects (MEs) that could lead to ion suppression or ion enhancement. This phenomenon can exert a deleterious impact on the ionization efficacy of an analyte and subsequently on the important method performance parameters. LC-MS susceptibility to MEs is the main challenge of this technique in the analysis of complex matrices such as biological and food samples. Nowadays, the assessment, estimation, and overcoming of the MEs before developing a method is mandatory in any analysis. Two main approaches including the post-column infusion and post-extraction spike are proposed to determine the degree of MEs. Different strategies can be adopted to reduce or eliminate MEs depending on the complexity of the matrix. This could be done by improving extraction and clean-up methods, changing the type of ionization employed, optimization of liquid chromatography conditions, and using corrective calibration methods. This review article will provide an overview of the MEs as the Achilles heel of the LC-MS technique, the causes of ME occurrence, their consequences, and systemic approaches towards overcoming MEs during LC-MS-based multi-analyte procedures.
Collapse
Affiliation(s)
- Azadeh Nasiri
- Department of Pharmacology and Toxicology, School of Pharmacy Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Food Safety Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Reza Jahani
- Department of Pharmacology and Toxicology, School of Pharmacy Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Shaya Mokhtari
- Central Research Laboratories, Shahid Beheshti University of Medical Sciences, Tehran, Iran. .,Phytochemistry Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Hassan Yazdanpanah
- Department of Pharmacology and Toxicology, School of Pharmacy Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Food Safety Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Bahram Daraei
- Department of Pharmacology and Toxicology, School of Pharmacy Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Mehrdad Faizi
- Department of Pharmacology and Toxicology, School of Pharmacy Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Farzad Kobarfard
- Department of Medicinal Chemistry, School of Pharmacy, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Phytochemistry Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.,Central Research Laboratories, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
3
|
Compensate for or Minimize Matrix Effects? Strategies for Overcoming Matrix Effects in Liquid Chromatography-Mass Spectrometry Technique: A Tutorial Review. Molecules 2020; 25:molecules25133047. [PMID: 32635301 PMCID: PMC7412464 DOI: 10.3390/molecules25133047] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 06/30/2020] [Accepted: 07/01/2020] [Indexed: 11/16/2022] Open
Abstract
In recent decades, mass spectrometry techniques, particularly when combined with separation methods such as high-performance liquid chromatography, have become increasingly important in pharmaceutical, bio-analytical, environmental, and food science applications because they afford high selectivity and sensitivity. However, mass spectrometry has limitations due to the matrix effects (ME), which can be particularly marked in complex mixes, when the analyte co-elutes together with other molecules, altering analysis results quantitatively. This may be detrimental during method validation, negatively affecting reproducibility, linearity, selectivity, accuracy, and sensitivity. Starting from literature and own experience, this review intends to provide a simple guideline for selecting the best operative conditions to overcome matrix effects in LC-MS techniques, to obtain the best result in the shortest time. The proposed methodology can be of benefit in different sectors, such as pharmaceutical, bio-analytical, environmental, and food sciences. Depending on the required sensitivity, analysts may minimize or compensate for ME. When sensitivity is crucial, analysis must try to minimize ME by adjusting MS parameters, chromatographic conditions, or optimizing clean-up. On the contrary, to compensate for ME analysts should have recourse to calibration approaches depending on the availability of blank matrix. When blank matrices are available, calibration can occur through isotope labeled internal standards and matrix matched calibration standards; conversely, when blank matrices are not available, calibration can be performed through isotope labeled internal standards, background subtraction, or surrogate matrices. In any case, an adjusting of MS parameters, chromatographic conditions, or a clean-up are necessary.
Collapse
|
4
|
Dong-Wei C, Yuan Z, Xiao-Yi D, Yu Z, Guo-Hui L, Xue-Song F. Progress in Pretreatment and Analytical Methods of Coumarins: An Update since 2012 - A Review. Crit Rev Anal Chem 2020; 51:503-526. [PMID: 32314593 DOI: 10.1080/10408347.2020.1750338] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Coumarins are widely used due to their wide range of biological activities, but the long-term or excessive use of coumarin flavors can pose serious health hazards. Therefore, sensitive and specific methods for the quantification of these compounds in different matrices have been developed. In this review, an updated overview of the latest trends in sample preparation techniques and methods used to detect coumarins from March 2012 to April 2019 is provided. This study reviews different analytical methods (such as liquid chromatography coupled with different detectors, electrochemical sensors, capillary electrophoresis, etc.) and different pretreatment methods (such as liquid-liquid extraction, solid-phase extraction, dispersive liquid-liquid microextraction, etc.). Different methods for the pretreatment and determination of coumarins in plant, food, environmental, pharmaceutical and biological samples are summarized, discussed and compared.HighlightsProgress in pretreatment and analytical methods of coumarins are summarized.Fundamentals, instrumentation and applications of purification and quantification are summarized and compared.Optimization of experimental conditions are discussed.Newly emerged eco-friendly methods are introduced.
Collapse
Affiliation(s)
- Cui Dong-Wei
- School of Pharmacy, China Medical University, Shenyang, China
| | - Zhang Yuan
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Duan Xiao-Yi
- School of Pharmacy, China Medical University, Shenyang, China
| | - Zhou Yu
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Li Guo-Hui
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Feng Xue-Song
- School of Pharmacy, China Medical University, Shenyang, China
| |
Collapse
|
5
|
Strategies for effective development of ultra-sensitive LC–MS/MS assays: application to a novel STING agonist. Bioanalysis 2020; 12:467-484. [DOI: 10.4155/bio-2020-0038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Background: The continual need for the development and validation of ultra-sensitive (low pg/ml) LC–MS/MS assays in the pharmaceutical industry is largely driven by the ultra-low analyte exposure or very low sample volume. Methodology: Strategies and systematic approaches for sensitivity enhancement are provided which cover all aspects of a LC–MS/MS bioanalysis. A case study where such strategies were applied for the validation of a 5.0 pg/ml assay for a STING agonist is discussed. Conclusion: Analytical protocols were developed to extract analytes from large volume of plasma samples (600 and 400 μl) with high throughput. The guidance provided in this publication can serve as a resource to influence LC–MS/MS method development activities.
Collapse
|
6
|
Dudzik D, Barbas-Bernardos C, García A, Barbas C. Quality assurance procedures for mass spectrometry untargeted metabolomics. a review. J Pharm Biomed Anal 2017; 147:149-173. [PMID: 28823764 DOI: 10.1016/j.jpba.2017.07.044] [Citation(s) in RCA: 206] [Impact Index Per Article: 29.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 07/28/2017] [Accepted: 07/29/2017] [Indexed: 12/16/2022]
Abstract
Untargeted metabolomics, as a global approach, has already proven its great potential and capabilities for the investigation of health and disease, as well as the wide applicability for other research areas. Although great progress has been made on the feasibility of metabolomics experiments, there are still some challenges that should be faced and that includes all sources of fluctuations and bias affecting every step involved in multiplatform untargeted metabolomics studies. The identification and reduction of the main sources of unwanted variation regarding the pre-analytical, analytical and post-analytical phase of metabolomics experiments is essential to ensure high data quality. Nowadays, there is still a lack of information regarding harmonized guidelines for quality assurance as those available for targeted analysis. In this review, sources of variations to be considered and minimized along with methodologies and strategies for monitoring and improvement the quality of the results are discussed. The given information is based on evidences from different groups among our own experiences and recommendations for each stage of the metabolomics workflow. The comprehensive overview with tools presented here might serve other researchers interested in monitoring, controlling and improving the reliability of their findings by implementation of good experimental quality practices in the untargeted metabolomics study.
Collapse
Affiliation(s)
- Danuta Dudzik
- Center for Metabolomics and Bioanalysis (CEMBIO), Faculty of Pharmacy, San Pablo CEU University, Boadilla del Monte, ES-28668, Madrid, Spain.
| | - Cecilia Barbas-Bernardos
- Center for Metabolomics and Bioanalysis (CEMBIO), Faculty of Pharmacy, San Pablo CEU University, Boadilla del Monte, ES-28668, Madrid, Spain.
| | - Antonia García
- Center for Metabolomics and Bioanalysis (CEMBIO), Faculty of Pharmacy, San Pablo CEU University, Boadilla del Monte, ES-28668, Madrid, Spain.
| | - Coral Barbas
- Center for Metabolomics and Bioanalysis (CEMBIO), Faculty of Pharmacy, San Pablo CEU University, Boadilla del Monte, ES-28668, Madrid, Spain.
| |
Collapse
|
7
|
Matrix effect management in liquid chromatography mass spectrometry: the internal standard normalized matrix effect. Bioanalysis 2017; 9:1093-1105. [PMID: 28737421 DOI: 10.4155/bio-2017-0059] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
LC-MS is becoming a standard for many applications, thanks to high sensitivity and selectivity; nevertheless, some issues are still present, particularly due to matrix effect (ME). Considering this, the use of optimal internal standards (ISs, usually stable-isotope labeled) is important, but not always possible because of cost or availability. Therefore, a deep investigation of the inter-lot variability of the ME and of the correcting power of the chosen IS (isotope-labeled or not) is mandatory. While the adoption of isotopically labeled ISs considered as a 'gold standard' to mitigate ME impact on analytical results, there is not consensus about the standard technique to evaluate it during method validation. In this paper, currently available techniques to evaluate, reduce or counterbalance ME are presented and discussed. Finally, these techniques were summarized in a flowchart for a robust management of ME, particularly considering the concept of 'internal standard normalized ME'.
Collapse
|
8
|
Sahu PK, Ramisetti NR, Cecchi T, Swain S, Patro CS, Panda J. An overview of experimental designs in HPLC method development and validation. J Pharm Biomed Anal 2017; 147:590-611. [PMID: 28579052 DOI: 10.1016/j.jpba.2017.05.006] [Citation(s) in RCA: 158] [Impact Index Per Article: 22.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 05/01/2017] [Accepted: 05/04/2017] [Indexed: 01/25/2023]
Abstract
Chemometric approaches have been increasingly viewed as precious complements to high performance liquid chromatographic practices, since a large number of variables can be simultaneously controlled to achieve the desired separations. Moreover, their applications may efficiently identify and optimize the significant factors to accomplish competent results through limited experimental trials. The present manuscript discusses usefulness of various chemometric approaches in high and ultra performance liquid chromatography for (i) methods development from dissolution studies and sample preparation to detection, considering the progressive substitution of traditional detectors with tandem mass spectrometry instruments and the importance of stability indicating assays (ii) method validation through screening and optimization designs. Choice of appropriate types of experimental designs so as to either screen the most influential factors or optimize the selected factors' combination and the mathematical models in chemometry have been briefly recalled and the advantages of chemometric approaches have been emphasized. The evolution of the design of experiments to the Quality by Design paradigm for method development has been reviewed and the Six Sigma practice as a quality indicator in chromatography has been explained. Chemometric applications and various strategies in chromatographic separations have been described.
Collapse
Affiliation(s)
- Prafulla Kumar Sahu
- Department of Pharmaceutical Analysis and Quality Assurance, Raghu College of Pharmacy, Dakamarri, Bheemunipatnam Mandal, Visakhapatnam, 531162, Andhra Pradesh, India
| | - Nageswara Rao Ramisetti
- Analytical Chemistry Division, CSIR-Indian Institute of Chemical Technology (IICT), Tarnaka, Hyderabad, 500007, Telangana, India.
| | - Teresa Cecchi
- Chemistry Department, ITT MONTANI, Via Montani 7, 63900, Fermo, FM, Italy.
| | - Suryakanta Swain
- Department of Pharmaceutics, SIMS College of Pharmacy, Mangaladas Nagar, Vijayawada Road, Guntur, 522 001, Andhra Pradesh, India
| | - Chandra Sekhar Patro
- Department of Pharmaceutical Analysis and Quality Assurance, Raghu College of Pharmacy, Dakamarri, Bheemunipatnam Mandal, Visakhapatnam, 531162, Andhra Pradesh, India
| | - Jagadeesh Panda
- Department of Pharmaceutical Analysis and Quality Assurance, Raghu College of Pharmacy, Dakamarri, Bheemunipatnam Mandal, Visakhapatnam, 531162, Andhra Pradesh, India
| |
Collapse
|
9
|
Mei S, Luo X, Li X, Li Q, Huo J, Yang L, Zhu L, Feng W, Zhou J, Shi G, Zhao Z. Development and validation of an LC-MS/MS method for the determination of tigecycline in human plasma and cerebrospinal fluid and its application to a pharmacokinetic study. Biomed Chromatogr 2016; 30:1992-2002. [PMID: 27245381 DOI: 10.1002/bmc.3776] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2016] [Revised: 05/23/2016] [Accepted: 05/28/2016] [Indexed: 11/07/2022]
Affiliation(s)
- Shenghui Mei
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
- Department of Clinical Pharmacology, College of Pharmaceutical Sciences, Capital Medical University, Beijing, 100045, People's Republic of China
| | - Xuying Luo
- Intensive Care Unit, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Xingang Li
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
- Department of Clinical Pharmacology, College of Pharmaceutical Sciences, Capital Medical University, Beijing, 100045, People's Republic of China
| | - Qian Li
- Intensive Care Unit, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Jiping Huo
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Li Yang
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
- Department of Clinical Pharmacology, College of Pharmaceutical Sciences, Capital Medical University, Beijing, 100045, People's Republic of China
| | - Leting Zhu
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Weixing Feng
- Department of Neurology, Beijing Children's Hospital, Capital Medical University, Beijing, 100045, People's Republic of China
| | - Jianxin Zhou
- Intensive Care Unit, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Guangzhi Shi
- Intensive Care Unit, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
| | - Zhigang Zhao
- Department of Pharmacy, Beijing Tiantan Hospital, Capital Medical University, 6 TiantanXili, Dongcheng District, Beijing, 100050, People's Republic of China
- Department of Clinical Pharmacology, College of Pharmaceutical Sciences, Capital Medical University, Beijing, 100045, People's Republic of China
| |
Collapse
|
10
|
Determination of Underivatized Glyphosate Residues in Plant-Derived Food with Low Matrix Effect by Solid Phase Extraction-Liquid Chromatography-Tandem Mass Spectrometry. FOOD ANAL METHOD 2016. [DOI: 10.1007/s12161-016-0468-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
11
|
Matrix effect explained by unexpected formation of peptide in acidified plasma. Bioanalysis 2015; 7:295-306. [PMID: 25697188 DOI: 10.4155/bio.14.271] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
AIM Peak distortion and strong signal enhancement was observed when applying a bioanalytical method based on mixed-mode SPE, hydrophilic interaction chromatography and ESI-MS to acidified rabbit plasma samples. RESULTS High-resolution ESI-MS and N-terminal peptide sequencing revealed a peptide NFQNAL, which was confirmed by H/D exchange ESI-MS. CONCLUSION The peptide causing the observed matrix effect was formed by enzymatic degradation of serum albumin at pH 3. Degradation required both acidification and presence of other plasma constituents in addition to albumin to take place. The degree of signal enhancement correlated to the level of NFQNAL in the ion source as measured by MS, with a maximal enhancement factor of 3 at intermediate levels of NFQNAL. The interference was eliminated by changing to another type of hydrophilic interaction chromatography column.
Collapse
|
12
|
Vats P, Verma SM, Khuroo A, Monif T. Effects of Sample Processing Techniques and Instrument Model on Matrix Effect in LC-MS/MS for a Model Drug. J LIQ CHROMATOGR R T 2015. [DOI: 10.1080/10826076.2015.1042978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Poonam Vats
- Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., Gurgaon, Haryana, India
| | - S. Manaswita Verma
- Department of Pharmaceutical Sciences, Birla Institute of Technology, Mesra, Ranchi, Jharkhand, India
| | - Arshad Khuroo
- Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., Gurgaon, Haryana, India
| | - Tausif Monif
- Department of Clinical Pharmacology and Pharmacokinetics, Ranbaxy Laboratories Ltd., Gurgaon, Haryana, India
| |
Collapse
|
13
|
Plassmann MM, Brack W, Krauss M. Extending analysis of environmental pollutants in human urine towards screening for suspected compounds. J Chromatogr A 2015; 1394:18-25. [DOI: 10.1016/j.chroma.2015.03.040] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Revised: 03/17/2015] [Accepted: 03/18/2015] [Indexed: 10/23/2022]
|
14
|
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part II. Anal Chim Acta 2015; 870:8-28. [DOI: 10.1016/j.aca.2015.02.016] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2015] [Accepted: 02/09/2015] [Indexed: 11/17/2022]
|
15
|
Abstract
Methods started in discovery are optimized as they progress through preclinical and clinical development. Making a robust assay includes testing individual steps for consistency and points of failure. Assays may be transferred, optimized and revalidated several times. A rugged assay will not only meet regulatory requirements, but will execute with a low failure rate and confirm results under repeat analysis. Challenging aspects such as differential recovery, sample stabilization, resolution of isomers or conjugate analysis must be tackled and made routine. The proper selection of the IS can overcome limitations. It is best to know the potential points of failure before a study has started, but lessons learned from each study also provide invaluable insights to improve assay ruggedness.
Collapse
|
16
|
Yaroshenko DV, Kartsova LA. Matrix effect and methods for its elimination in bioanalytical methods using chromatography-mass spectrometry. JOURNAL OF ANALYTICAL CHEMISTRY 2014. [DOI: 10.1134/s1061934814040133] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
17
|
|
18
|
Huo J, Wang H, Hu P, Li P, Liu J, Jiang J. Determination of pseudo-ginsenoside GQ in human plasma by high performance liquid chromatography-tandem mass spectrometry. Biomed Chromatogr 2013; 27:1701-7. [PMID: 23852954 DOI: 10.1002/bmc.2982] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2013] [Revised: 05/25/2013] [Accepted: 05/27/2013] [Indexed: 11/05/2022]
Affiliation(s)
- Jiping Huo
- Clinical Pharmacology Research Center; Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College; Beijing 100730 China
| | - Hongyun Wang
- Clinical Pharmacology Research Center; Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College; Beijing 100730 China
| | - Pei Hu
- Clinical Pharmacology Research Center; Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College; Beijing 100730 China
| | - Pingya Li
- Institute of Frontier Medical Science of Jilin University; Changchun 130021 China
| | - Jinping Liu
- Institute of Frontier Medical Science of Jilin University; Changchun 130021 China
| | - Ji Jiang
- Clinical Pharmacology Research Center; Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College; Beijing 100730 China
| |
Collapse
|
19
|
Pei Q, zhang B, Tan H, Liu L, Peng X, Li Z, Huang P, Luo M, Zuo X, Guo C, Yang G. Development and validation of an LC–MS/MS method for the determination of tolvaptan in human plasma and its application to a pharmacokinetic study. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 913-914:84-9. [PMID: 23274625 DOI: 10.1016/j.jchromb.2012.11.027] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2012] [Revised: 11/12/2012] [Accepted: 11/28/2012] [Indexed: 11/27/2022]
|
20
|
Kitanovski Z, Grgić I, Vermeylen R, Claeys M, Maenhaut W. Liquid chromatography tandem mass spectrometry method for characterization of monoaromatic nitro-compounds in atmospheric particulate matter. J Chromatogr A 2012; 1268:35-43. [PMID: 23122275 DOI: 10.1016/j.chroma.2012.10.021] [Citation(s) in RCA: 66] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Revised: 10/04/2012] [Accepted: 10/08/2012] [Indexed: 10/27/2022]
Abstract
Nitrogen-containing organic compounds in the atmosphere have drawn attention owing to their impact on aerosol chemistry and physics and their potential adverse effects on the biosphere. Among them, nitrocatechols and their homologs have recently been associated with biomass burning. In the present study, nitrocatechols, nitrophenols, nitroguaiacols and nitrosalicylic acids (NSAs) were simultaneously quantified for the first time by using a new analytical method based on liquid chromatography/tandem mass spectrometry, which was systematically optimized and validated. Several analyte specific issues regarding the sample preparation and chromatographic analysis were addressed in order to ensure method sensitivity, precision, and accuracy. Sample matrix effects were thoroughly investigated in order to ensure method specificity. The method was found to be sensitive with limits of detection ranging from 0.1 to 1.0 μg L(-1), and with accuracy generally between 90 and 104%. The relative standard deviations for repeatability and intermediate precision were better than 4% and 9%, respectively. The method was applied to the analysis of winter and summer PM(10) samples from the city of Ljubljana, Slovenia. Aerosol concentrations as high as 152 and 134 ng m(-3) were obtained for the major aerosol nitro-aromatics: 4-nitrocatechol (4NC) and methyl-nitrocatechols (MNCs), respectively. Up to 500-times higher concentrations of 4NC and MNCs were found in winter compared to summer aerosols. The correlation analysis for winter samples showed that 4NC, MNCs, and NSAs are strongly inter-correlated (R(2)=0.84-0.96). Significant correlations between these analytes and anhydrosugars support their proposed origin from biomass burning. The studied nitro-aromatics were found to constitute a non-negligible fraction (around 1%) of the organic carbon.
Collapse
Affiliation(s)
- Zoran Kitanovski
- Laboratory for Analytical Chemistry, National Institute of Chemistry, Hajdrihova 19, SI-1000 Ljubljana, Slovenia.
| | | | | | | | | |
Collapse
|
21
|
Xue YJ, Melo B, Vallejo M, Zhao Y, Tang L, Chen YS, Keller KM. An integrated bioanalytical method development and validation approach: case studies. Biomed Chromatogr 2011; 26:1215-27. [DOI: 10.1002/bmc.2682] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2011] [Revised: 11/22/2011] [Accepted: 11/23/2011] [Indexed: 11/11/2022]
Affiliation(s)
- Y.-J. Xue
- Celgene Corporation; Summit; NJ; USA
| | | | | | | | | | | | - Karin M. Keller
- Department of Chemistry and Biochemistry; University of Texas; Austin; TX; USA
| |
Collapse
|
22
|
Berg T, Strand DH. ¹³C labelled internal standards--a solution to minimize ion suppression effects in liquid chromatography-tandem mass spectrometry analyses of drugs in biological samples? J Chromatogr A 2011; 1218:9366-74. [PMID: 22119139 DOI: 10.1016/j.chroma.2011.10.081] [Citation(s) in RCA: 119] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2011] [Revised: 10/24/2011] [Accepted: 10/26/2011] [Indexed: 11/17/2022]
Abstract
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is frequently used to identify and quantify drugs in human biological samples due to the high selectivity and sensitivity of this technique. However, ion suppression effects caused by co-eluting compounds: drugs, metabolites, matrix components, impurities and degradation products, are a major concern. Stable isotope labelled internal standards (SIL ISs), usually deuterium ((2)H) labelled, are often used to compensate for these effects. In many LC separations the retention times of (2)H labelled ISs and their analogues will differ. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is increasingly being used for bio-analysis. With the better chromatographic resolution provided with sub 2 μm particles, larger separation between analytes and their (2)H labelled analogues can be expected, which might reduce the benefits of the SIL IS. There is a greater difference in physico-chemical properties between hydrogen isotopes than between isotopes of other elements. (13)C, (15)N and (18)O labelled ISs are more similar to their analytes than (2)H labelled ISs and thereby expected to behave more similarly in chromatographic separations. In this study we have investigated the use of (13)C and (2)H labelled ISs for the determination of amphetamine and methamphetamine by UPLC-MS/MS. The (13)C labelled ISs were co eluting with their analytes under different chromatographic conditions while the (2)H labelled ISs and their analytes were slightly separated. An improved ability to compensate for ion suppression effects were observed when the (13)C labelled ISs were used. Furthermore, an UPLC-MS/MS method for determination of amphetamine and methamphetamine in urine using (13)C labelled ISs has been developed and validated. Unfortunately, there are few (13)C labelled ISs commercial available today. If more (13)C labelled ISs become commercial available they may well be the coming solution to minimize ion suppression/enhancement effects in LC-MS/MS analyses of drugs in biological samples.
Collapse
Affiliation(s)
- Thomas Berg
- Division of Forensic Toxicology and Drug Abuse, Norwegian Institute of Public Health, Oslo, Norway.
| | | |
Collapse
|
23
|
Fenoll J, Martínez A, Hellín P, Flores P. Simultaneous determination of ascorbic and dehydroascorbic acids in vegetables and fruits by liquid chromatography with tandem-mass spectrometry. Food Chem 2011. [DOI: 10.1016/j.foodchem.2010.12.140] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
24
|
Goicoechea H, Culzoni M, García MG, Galera MM. Chemometric strategies for enhancing the chromatographic methodologies with second-order data analysis of compounds when peaks are overlapped. Talanta 2011; 83:1098-107. [DOI: 10.1016/j.talanta.2010.07.057] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2010] [Revised: 07/13/2010] [Accepted: 07/24/2010] [Indexed: 10/19/2022]
|
25
|
A dual validation approach to detect anthelmintic residues in bovine liver over an extended concentration range. Talanta 2010; 83:14-24. [DOI: 10.1016/j.talanta.2010.08.025] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Revised: 08/12/2010] [Accepted: 08/17/2010] [Indexed: 11/22/2022]
|
26
|
Urban M, Enot DP, Dallmann G, Körner L, Forcher V, Enoh P, Koal T, Keller M, Deigner HP. Complexity and pitfalls of mass spectrometry-based targeted metabolomics in brain research. Anal Biochem 2010; 406:124-31. [DOI: 10.1016/j.ab.2010.07.002] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2010] [Revised: 07/01/2010] [Accepted: 07/02/2010] [Indexed: 10/19/2022]
|
27
|
Critical topics in ensuring data quality in bioanalytical LC–MS method development. Bioanalysis 2010; 2:1051-72. [DOI: 10.4155/bio.10.60] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The use of LC–MS for bioanalysis of pharmaceuticals is entering its third decade and may be considered to be a mature technology. In many respects this is true, considering the advances made in such areas as instrument performance, electronics, software and automation of use. However, there remain instrumental and noninstrumental areas that require significant attention to ensure data quality. Increasing regulatory focus on analytical method performance and unaddressed method issues require the bioanalyst to understand those areas that most greatly impact data quality. This review will focus on instrumental and noninstrumental areas that can influence data quality, including reference standard and internal standard quality and physicochemical properties, matrix effects, stability in matrix, sample preparation, LC and MS.
Collapse
|
28
|
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry. J Chromatogr A 2010; 1217:3929-37. [DOI: 10.1016/j.chroma.2009.11.060] [Citation(s) in RCA: 493] [Impact Index Per Article: 35.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2009] [Revised: 10/19/2009] [Accepted: 11/18/2009] [Indexed: 11/20/2022]
|
29
|
Dai SY, Herrman TJ. Evaluation of two liquid chromatography/tandem mass spectrometry platforms for quantification of monensin in animal feed and milk. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:1431-1438. [PMID: 20411582 DOI: 10.1002/rcm.4533] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Monensin is an anticoccidial drug that has been used as an additive in medicated feed. The United States Food and Drug Administration (USFDA) has included monensin in the national surveillance schemes for residues in foodstuff. In this study, two simple, selective and rapid methods were developed to determine monensin content in animal feed and milk. The methods enabled the detection of monensin residues as low as 1 ppb. Moreover, the two methods were used as models to compare two common liquid chromatography/tandem mass spectrometry (LC/MS/MS) platforms; an LC linear ion trap (LC/LIT) and an LC triple quadrupole (LC/QqQ). The two instrument platforms were evaluated for their matrix effect dependence, precision and accuracy. The LC/QqQ presented a lower limit of detection and limit of quantitation (LOD and LOQ) and showed less matrix dependence as compared to the LC/LIT. The LC/QqQ instrument also demonstrated a better intermediate precision. For example, the intermediate precision standard deviation calculated for 27 analyses across three days was 4% and 11% for LC/QqQ and LC/LIT, respectively. Overall, the LC/QqQ represents a better choice for analysis of monensin with respect to LOD, LOQ, matrix interference and precision.
Collapse
Affiliation(s)
- Susie Y Dai
- Office of the Texas State Chemist and the Department of Veterinary Pathobiology, Texas A&M University, College Station, TX 77843, USA.
| | | |
Collapse
|
30
|
Multiclass, multiresidue method for the detection of antibiotic residues in distillers grains by liquid chromatography and ion trap tandem mass spectrometry. J Chromatogr A 2010; 1217:3076-84. [DOI: 10.1016/j.chroma.2010.02.081] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2009] [Revised: 02/19/2010] [Accepted: 02/26/2010] [Indexed: 11/22/2022]
|
31
|
Abstract
Most steroid disorders of the adrenal cortex come to clinical attention in childhood and in order to investigate these problems, there are many challenges to the laboratory which need to be appreciated to a certain extent by clinicians. The analysis of sex steroids in biological fluids from neonates, over adrenarche and puberty present challenges of specificities and concentrations often in small sample sizes. Different reference ranges are also needed for interpretations. For around 40 years, quantitative assays for the steroids and their regulatory peptide hormones have been possible using immunoassay techniques. Problems are recognised and this review aims to summarise the benefits and failings of immunoassays and introduce where tandem mass spectrometry is anticipated to meet the clinical needs for steroid analysis in paediatric endocrine investigations. It is important to keep a dialogue between clinicians and the laboratory, especially when any laboratory result does not make sense in the clinical investigation.
Collapse
Affiliation(s)
- John W Honour
- Clinical Biochemistry, University College London Hospitals, London, England.
| |
Collapse
|
32
|
Tomaiuolo M, Vecchione G, Margaglione M, Pisanelli D, Grandone E. Stable-isotope dilution LC–ESI-MS/MS techniques for the quantification of total homocysteine in human plasma. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:3292-9. [DOI: 10.1016/j.jchromb.2009.07.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2009] [Revised: 07/03/2009] [Accepted: 07/15/2009] [Indexed: 11/25/2022]
|
33
|
Combating matrix effects in LC/ESI/MS: The extrapolative dilution approach. Anal Chim Acta 2009; 651:75-80. [DOI: 10.1016/j.aca.2009.07.060] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2009] [Revised: 07/21/2009] [Accepted: 07/23/2009] [Indexed: 11/17/2022]
|
34
|
Van Eeckhaut A, Lanckmans K, Sarre S, Smolders I, Michotte Y. Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:2198-207. [PMID: 19179125 DOI: 10.1016/j.jchromb.2009.01.003] [Citation(s) in RCA: 558] [Impact Index Per Article: 37.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2008] [Revised: 12/08/2008] [Accepted: 01/06/2009] [Indexed: 10/21/2022]
|
35
|
Abstract
Abstract
Background: Matrix effects can profoundly reduce the performance of electrospray ionization mass spectrometry. Preliminary observations indicated that the methanol used in the mobile phase could be a source of differential ionization or ion suppression.
Methods: Drug stability studies, analysis of biological extracts, mixing experiments, and postcolumn infusions were used to test 9 commercial methanols for ionization differences in liquid chromatography-tandem mass spectrometry assays for immunosuppressants. Area responses for the drugs and internal standards were compared for mobile phases prepared with each selected methanol. Postcolumn infusion experiments were performed to confirm the degree of ionization differences occurring at the ion source, and to evaluate the proportions of ammonium, sodium, and potassium adducts.
Results: The decrease in signal for the immunosuppressant drugs was shown to result from differential ionization associated with the selected methanols. Product ion intensity varied by 10-fold among the methanols tested. For sirolimus, tacrolimus, and mycophenolic acid, the percentage change in ionization was the same for the drug and its corresponding internal standard. Postcolumn sirolimus infusion evaluation revealed that a 1000-fold analyte concentration difference did not affect ionization. The proportions of ammonium, sodium, and potassium adducts of sirolimus precursor ions differed in relation to the source of methanol.
Conclusions: Organic solvents used in mobile phases and extract preparation of biological samples may be associated with ion suppression, affecting adduct formation and assay sensitivity.
Collapse
Affiliation(s)
- Thomas M Annesley
- Department of Pathology, University of Michigan Health Sciences Center, Ann Arbor, MI, USA.
| |
Collapse
|
36
|
Cristoni S, Basso E, Gerthoux P, Mocarelli P, Gonella E, Brambilla M, Crotti S, Bernardi LR. Surface-activated chemical ionization ion trap mass spectrometry for the analysis of cocaine and benzoylecgonine in hair after extraction and sample dilution. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:2515-23. [PMID: 17610217 DOI: 10.1002/rcm.3107] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Surface-activated chemical ionization (SACI) was employed for the analysis of cocaine and its metabolite, benzoylecgonine, extracted from hair. Following decontamination and acid hydrolysis procedures on the hair sample, the sample solution was diluted (1:10) and directly analyzed by liquid chromatography/surface-activated chemical ionization multiple collisional stage single reaction monitoring mass spectrometry (LC/SACI-MS(3)-SRM) without solid-phase extraction (SPE) pre-purification and concentration procedures. To increase the selectivity of the method, MS(3) was chosen instead of the less selective MS/MS. This data was compared with that achieved using gas chromatography/mass spectrometry (GC/MS), the reference method used by the Italian Government Institute of Health protocol. The limits of detection (LODs) were 0.003 ng/(mg hair) for cocaine and 0.02 ng/(mg hair) for benzoylecgonine and the limits of quantitation (LOQs) were 0.01 ng/(mg hair) for cocaine and 0.04 ng/(mg hair) for benzoylecgonine. The squared correlation coefficient (R(2)) of the calibration curve was 0.9887-0.9980 for cocaine and 0.9987-0.9997 for benzoylecgonine. The percent accuracy error was 2-5% for both cocaine and benzoylecgonine using the LC/SACI-MS(3)-SRM approach, whereas it was higher for benzoylecgonine (20-25%) using the LC/SACI-MS/MS-SRM approach compared with the GC/MS data due to hair matrix contamination. In both cases, high precision was achieved (1-3% precision error), which confirmed the stability of the developed methods.
Collapse
|