1
|
Syed SUAH, Maher S, Eijkel GB, Ellis SR, Jjunju F, Taylor S, Heeren RMA. Direct Ion Imaging Approach for Investigation of Ion Dynamics in Multipole Ion Guides. Anal Chem 2015; 87:3714-20. [DOI: 10.1021/ac5041764] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Sarfaraz U. A. H. Syed
- FOM Institute
AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands
- TI-COAST, Science Park
904, 1098 XH Amsterdam, The Netherlands
| | - Simon Maher
- Department
of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, United Kingdom
| | - Gert B. Eijkel
- FOM Institute
AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Shane R. Ellis
- FOM Institute
AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands
- M4I,
The Maastricht MultiModal Molecular Imaging Institute, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| | - Fred Jjunju
- Department
of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, United Kingdom
| | - Stephen Taylor
- Department
of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, United Kingdom
| | - Ron M. A. Heeren
- FOM Institute
AMOLF, Science Park 104, 1098 XG Amsterdam, The Netherlands
- TI-COAST, Science Park
904, 1098 XH Amsterdam, The Netherlands
- M4I,
The Maastricht MultiModal Molecular Imaging Institute, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
2
|
Syed SUAH, Eijkel GB, Kistemaker P, Ellis S, Maher S, Smith DF, Heeren RMA. Experimental investigation of the 2D ion beam profile generated by an ESI octopole-QMS system. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2014; 25:1780-1787. [PMID: 25113629 DOI: 10.1007/s13361-014-0958-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2014] [Revised: 06/08/2014] [Accepted: 06/08/2014] [Indexed: 06/03/2023]
Abstract
In this paper, we have employed an ion imaging approach to investigate the behavior of ions exiting from a quadrupole mass spectrometer (QMS) system that employs a radio frequency octopole ion guide before the QMS. An in-vacuum active pixel detector (Timepix) is employed at the exit of the QMS to image the ion patterns. The detector assembly simultaneously records the ion impact position and number of ions per pixel in every measurement frame. The transmission characteristics of the ion beam exiting the QMS are studied using this imaging detector under different operating conditions. Experimental results confirm that the ion spatial distribution exiting the QMS is heavily influenced by ion injection conditions. Furthermore, ion images from Timepix measurements of protein standards demonstrate the capability to enhance the quality of the mass spectral information and provide a detailed insight in the spatial distribution of different charge states (and hence different m/z) ions exiting the QMS.
Collapse
|
3
|
Bzdek BR, DePalma JW, Ridge DP, Laskin J, Johnston MV. Fragmentation Energetics of Clusters Relevant to Atmospheric New Particle Formation. J Am Chem Soc 2013; 135:3276-85. [DOI: 10.1021/ja3124509] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Bryan R. Bzdek
- Department of Chemistry and
Biochemistry, University of Delaware, Newark,
Delaware 19716, United States
| | - Joseph W. DePalma
- Department of Chemistry and
Biochemistry, University of Delaware, Newark,
Delaware 19716, United States
| | - Douglas P. Ridge
- Department of Chemistry and
Biochemistry, University of Delaware, Newark,
Delaware 19716, United States
| | - Julia Laskin
- Chemical and Material Sciences
Division, Pacific Northwest National Laboratory, P.O. Box 999, K8-88, Richland, Washington 99352, United States
| | - Murray V. Johnston
- Department of Chemistry and
Biochemistry, University of Delaware, Newark,
Delaware 19716, United States
| |
Collapse
|
4
|
Qi Y, Barrow MP, Li H, Meier JE, Van Orden SL, Thompson CJ, O'Connor PB. Absorption-mode: the next generation of Fourier transform mass spectra. Anal Chem 2012; 84:2923-9. [PMID: 22339804 DOI: 10.1021/ac3000122] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The Fourier transform spectrum can be presented in the absorption-mode (commonly used in FT-NMR), magnitude-mode (FT-ICR), and power-mode (engineering applications). As is routinely used in FT-NMR, it is well-known that the absorption-mode display gives a much narrower peak shape which greatly improves the spectrum; recently, the successful solution of the phase equation allowed broadband phase correction which makes it possible to apply the absorption-mode routinely in FT-ICR. With the empirical evidence provided herein, it has been confirmed that in addition to the improvement on resolving power, compared to the conventional magnitude-mode, the new absorption-mode improves the signal-to-noise ratio (S/N) of a spectrum by 1.4-fold and can improve the mass accuracy up to 2-fold with no extra cost in instrumentation. Therefore, it is worthwhile to apply and promote absorption-mode in routine FT-ICR experiments.
Collapse
Affiliation(s)
- Yulin Qi
- Department of Chemistry, University of Warwick, Coventry, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
5
|
Affiliation(s)
- Feng Xian
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
| | - Christopher L. Hendrickson
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, 1800
East Paul Dirac Drive, Tallahassee, Florida 32310-4005, United States
| | - Alan G. Marshall
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, 1800
East Paul Dirac Drive, Tallahassee, Florida 32310-4005, United States
| |
Collapse
|
6
|
Aizikov K, Smith DF, Chargin DA, Ivanov S, Lin TY, Heeren RMA, O'Connor PB. Vacuum compatible sample positioning device for matrix assisted laser desorption∕ionization Fourier transform ion cyclotron resonance mass spectrometry imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:054102. [PMID: 21639522 PMCID: PMC3117896 DOI: 10.1063/1.3594099] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2011] [Accepted: 05/03/2011] [Indexed: 05/19/2023]
Abstract
The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in ∼1 × 10(-8) mbar vacuum. The range of motion is set to 100 mm × 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption∕ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The "oversampling" MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.
Collapse
Affiliation(s)
- Konstantin Aizikov
- Cardiovascular Proteomics Center, Boston University School of Medicine, 670 Albany Street, Room 504 Boston, Massachusetts 02118, USA
| | | | | | | | | | | | | |
Collapse
|
7
|
Laskin J, Yang Z, Woods AS. Competition between covalent and noncovalent bond cleavages in dissociation of phosphopeptide-amine complexes. Phys Chem Chem Phys 2011; 13:6936-46. [PMID: 21387029 DOI: 10.1039/c1cp00029b] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Interactions between quaternary amino or guanidino groups with anions are ubiquitous in nature and have been extensively studied phenomenologically. However, little is known about the binding energies in non-covalent complexes containing these functional groups. Here, we present a first study focused on quantifying such interactions using complexes of phosphorylated A(3)pXA(3)-NH(2) (X = S, T, Y) peptides with decamethonium (DCM) or diaguanidinodecane (DGD) ligands as model systems. Time- and collision energy-resolved surface-induced dissociation (SID) of the singly charged complexes was examined using a specially configured Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS). Dissociation thresholds and activation energies were obtained from RRKM modeling of the experimental data that has been described and carefully characterized in our previous studies. For systems examined in this study, covalent bond cleavages resulting in phosphate abstraction by the cationic ligand are characterized by low dissociation thresholds and relatively tight transition states. In contrast, high dissociation barriers and large positive activation entropies were obtained for cleavages of non-covalent bonds. Dissociation parameters obtained from the modeling of the experimental data are in excellent agreement with the results of density functional theory (DFT) calculations. Comparison between the experimental data and theoretical calculations indicate that phosphate abstraction by the ligand is rather localized and mainly affected by the identity of the phosphorylated side chain. The hydrogen bonding in the peptide and ligand properties play a minor role in determining the energetics and dynamics of the phosphate abstraction channel.
Collapse
Affiliation(s)
- Julia Laskin
- Pacific Northwest National Laboratory, Chemical and Materials Sciences Division, P.O. Box 999, K8-88, Richland, Washington 99352, USA.
| | | | | |
Collapse
|
8
|
Smith DF, Aizikov K, Duursma MC, Giskes F, Spaanderman DJ, McDonnell LA, O’Connor PB, Heeren RMA. An external matrix-assisted laser desorption ionization source for flexible FT-ICR Mass spectrometry imaging with internal calibration on adjacent samples. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:130-7. [PMID: 21472551 PMCID: PMC3042104 DOI: 10.1007/s13361-010-0003-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2010] [Revised: 09/02/2010] [Accepted: 10/08/2010] [Indexed: 05/03/2023]
Abstract
We describe the construction and application of a new MALDI source for FT-ICR mass spectrometry imaging. The source includes a translational X-Y positioning stage with a 10×10 cm range of motion for analysis of large sample areas, a quadrupole for mass selection, and an external octopole ion trap with electrodes for the application of an axial potential gradient for controlled ion ejection. An off-line LC MALDI MS/MS run demonstrates the utility of the new source for data- and position-dependent experiments. A FT-ICR MS imaging experiment of a coronal rat brain section yields ∼200 unique peaks from m/z 400-1100 with corresponding mass-selected images. Mass spectra from every pixel are internally calibrated with respect to polymer calibrants collected from an adjacent slide.
Collapse
Affiliation(s)
- Donald F. Smith
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Konstantin Aizikov
- Mass Spectrometry Resource, Department of Biochemistry, Boston University School of Medicine, Boston, MA USA
| | - Marc C. Duursma
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Frans Giskes
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Dirk-Jan Spaanderman
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Liam A. McDonnell
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
- Present Address: Department of Parasitology, Leiden University Medical Center, P.O. Box 9600, 2300 RC Leiden, The Netherlands
| | - Peter B. O’Connor
- Mass Spectrometry Resource, Department of Biochemistry, Boston University School of Medicine, Boston, MA USA
- Present Address: Department of Chemistry, University of Warwick, Coventry, UK
| | - Ron M. A. Heeren
- FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| |
Collapse
|
9
|
Barbu IMT, Smith DF, van Breukelen B, van der Burgt YEM, Duursma MC, Heck AJR, Heeren RMA, Krijgsveld J. On-the-fly targeted selection of labeled peptides in liquid chromatography/mass spectrometry based quantitative proteomics. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:239-241. [PMID: 20013948 DOI: 10.1002/rcm.4385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
10
|
Geels RBJ, Calmat S, Heck AJR, van der Vies SM, Heeren RMA. Thermal activation of the co-chaperonins GroES and gp31 probed by mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:3633-3641. [PMID: 18972453 DOI: 10.1002/rcm.3782] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Many biological active proteins are assembled in protein complexes. Understanding the (dis)assembly of such complexes is therefore of major interest. Here we use mass spectrometry to monitor the disassembly induced by thermal activation of the heptameric co-chaperonins GroES and gp31. We use native electrospray ionization mass spectrometry (ESI-MS) on a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer to monitor the stoichiometry of the chaperonins. A thermally controlled electrospray setup was employed to analyze conformational and stoichiometric changes of the chaperonins at varying temperature. The native ESI-MS data agreed well with data obtained from fluorescence spectroscopy as the measured thermal dissociation temperatures of the complexes were in good agreement. Furthermore, we observed that thermal denaturing of GroES and gp31 proceeds via intermediate steps of all oligomeric forms, with no evidence of a transiently stable unfolded heptamer. We also evaluated the thermal dissociation of the chaperonins in the gas phase using infrared multiphoton dissociation (IRMPD) for thermal activation. Using gas-phase activation the smaller (2-4) oligomers were not detected, only down to the pentamer, whereafter the complex seemed to dissociate completely. These results demonstrate clearly that conformational changes of GroES and gp31 due to heating in solution and in the gas phase are significantly different.
Collapse
Affiliation(s)
- Rimco B J Geels
- FOM Institute for Atomic and Molecular Physics, Kruislaan 407, 1098 SJ Amsterdam, The Netherlands
| | | | | | | | | |
Collapse
|