Chavez JD, Park SG, Mohr JP, Bruce JE. Applications and advancements of FT-ICR-MS for interactome studies. MASS SPECTROMETRY REVIEWS 2022; 41:248-261. [PMID: 33289940 PMCID: PMC8184889 DOI: 10.1002/mas.21675] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2020] [Revised: 10/16/2020] [Accepted: 10/16/2020] [Indexed: 05/05/2023]
Abstract
The set of all intra- and intermolecular interactions, collectively known as the interactome, is currently an unmet challenge for any analytical method, but if measured, could provide unparalleled insight on molecular function in living systems. Developments and applications of chemical cross-linking and high-performance mass spectrometry technologies are beginning to reveal details on how proteins interact in cells and how protein conformations and interactions inside cells change with phenotype or during drug treatment or other perturbations. A major contributor to these advances is Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) technology and its implementation with accurate mass measurements on cross-linked peptide-pair precursor and fragment ions to enable improved identification methods. However, these applications place increased demands on mass spectrometer performance in terms of high-resolution spectral acquisition rates for on-line MSn experiments. Moreover, FT-ICR-MS also offers unique opportunities to develop and implement parallel ICR cells for multiplexed signal acquisition and the potential to greatly advance accurate mass acquisition rates for interactome studies. This review highlights our efforts to exploit accurate mass FT-ICR-MS technologies with chemical cross-linking and developments being pursued to realize parallel MS array capabilities that will further advance visualization of the interactome.
Collapse
Affiliation(s)
- Juan D. Chavez
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Jared P. Mohr
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - James E. Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
2
|
Nagornov KO, Tsybin OY, Nicol E, Kozhinov AN, Tsybin YO. Fourier transform ion cyclotron resonance mass spectrometry at the true cyclotron frequency. MASS SPECTROMETRY REVIEWS 2022; 41:314-337. [PMID: 33462876 DOI: 10.1002/mas.21681] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 12/24/2020] [Accepted: 12/26/2020] [Indexed: 06/12/2023]
Abstract
Ion cyclotron resonance (ICR) cells provide stability and coherence of ion oscillations in crossed electric and magnetic fields over extended periods of time. Using the Fourier transform enables precise measurements of ion oscillation frequencies. These precisely measured frequencies are converted into highly accurate mass-to-charge ratios of the analyte ions by calibration procedures. In terms of resolution and mass accuracy, Fourier transform ICR mass spectrometry (FT-ICR MS) offers the highest performance of any MS technology. This is reflected in its wide range of applications. However, in the most challenging MS application, for example, imaging, enhancements in the mass accuracy of fluctuating ion fluxes are required to continue advancing the field. One approach is to shift the ion signal power into the peak corresponding to the true cyclotron frequency instead of the reduced cyclotron frequency peak. The benefits of measuring the true cyclotron frequency include increased tolerance to electric fields within the ICR cell, which enhances frequency measurement precision. As a result, many attempts to implement this mode of FT-ICR MS operation have occurred. Examples of true cyclotron frequency measurements include detection of magnetron inter-harmonics of the reduced cyclotron frequency (i.e., the sidebands), trapping field-free (i.e., screened) ICR cells, and hyperbolic ICR cells with quadrupolar ion detection. More recently, ICR cells with spatially distributed ion clouds have demonstrated attractive performance characteristics for true cyclotron frequency ion detection. Here, we review the corresponding developments in FT-ICR MS over the past 40 years.
Collapse
Affiliation(s)
| | - Oleg Y Tsybin
- Ion Physics and Mass Spectrometry Laboratory, Peter The Great State Polytechnic University, Saint-Petersburg, Russia
| | - Edith Nicol
- Laboratoire de Chimie Moléculaire, CNRS, UMR 9168, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France
| | | | | |
Collapse
|
3
|
Park SG, Mohr JP, Anderson GA, Bruce JE. Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2021; 465:116578. [PMID: 33897275 PMCID: PMC8059610 DOI: 10.1016/j.ijms.2021.116578] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with liquid chromatography (LC) is a powerful combination useful in many research areas due to the utility of high mass resolving power and mass measurement accuracy for studying highly complex samples. Ideally, every analyte in a complex sample can be subjected to accurate mass MS/MS analysis to aid in identification. FT-ICR MS can provide high mass resolving power and mass accuracy at the cost of long data acquisition periods, reducing the number of spectra that can be acquired per unit time. Frequency multiple signal acquisition has long been realized as an attractive method to obtain high mass resolving power and mass accuracy with shorter data acquisition periods. However, one of the limitations associated with frequency multiple signal acquisition is reduced signal intensity as compared to a traditional dipole detector. In this study, we demonstrated the use of a novel ICR cell to improve frequency multiple signal intensity and investigated the potential use of frequency multiple acquisition for proteome measurements. This novel ICR cell containing both dipole and frequency multiple detection electrodes was installed on a 7T FT-ICR MS coupled to an LC system. Tryptic digests of HeLa cell lysates were analyzed using dipole and frequency multiple detectors by holding either the mass resolving power or signal acquisition time constant. Compared to dipole detection, second frequency multiple detection yielded 36% or 45% more unique identified peptides from HeLa cell lysates at twice the scan rate or twice the mass resolving power, respectively. These results indicate that frequency multiple signal acquisition with either the same resolving power or the same signal acquisition duration as used with dipole signals can produce a significant increase in the number of peptides identified in complex proteome samples.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | - Jared P Mohr
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
4
|
Park SG, Anderson GA, Bruce JE. Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:719-726. [PMID: 31967815 PMCID: PMC7970440 DOI: 10.1021/jasms.9b00144] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for high-resolution analysis of biomolecules. However, relatively long signal acquisition periods are needed to achieve mass spectra with high resolution. The use of multiple detector electrodes for detection of harmonic frequencies has been introduced as one approach to increase scan rate for a given resolving power or to obtain increased resolving power for a given detection period. The achieved resolving power and scan rate increase linearly with the order of detected harmonic signals. In recent years, ICR cell geometries have been investigated to increase the order of the harmonic frequencies and enhance harmonic signal intensities. In this study, we demonstrated PCB-based ICR cell designs with dipole and sixth harmonic detectors for parallel detection of fundamental and harmonic (6f) signals. The sixth harmonic signals from the sixth harmonic detector showed an expected 6 times higher resolving power with (M + 3H)3+ charge state insulin ions as compared with that from fundamental signals from the dipole detector. Moreover, the insulin isotopic peaks with sixth harmonic frequency signals acquired with the sixth harmonic detector were resolved for a 40 ms data acquisition period but unresolved with the same duration dipole detector signals, corresponding to a 6-fold improvement in achievable spectral acquisition rates for a given resolving power.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, Washington 98109, United States
| | - Gordon A Anderson
- GAA Custom Engineering, LLC, Benton City, Washington 99320, United States
| | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, Washington 98109, United States
| |
Collapse
|
5
|
Park SG, Anderson GA, Bruce JE. Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1394-1402. [PMID: 29691781 PMCID: PMC6537869 DOI: 10.1007/s13361-018-1954-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 03/01/2018] [Accepted: 03/21/2018] [Indexed: 05/22/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for the study of complex biological samples due to its high resolution and mass measurement accuracy. However, the relatively long signal acquisition periods needed to achieve high resolution can serve to limit applications of FTICR-MS. The use of multiple pairs of detector electrodes enables detection of harmonic frequencies present at integer multiples of the fundamental cyclotron frequency, and the obtained resolving power for a given acquisition period increases linearly with the order of harmonic signal. However, harmonic signal detection also increases spectral complexity and presents challenges for interpretation. In the present work, ICR cells with independent dipole and harmonic detection electrodes and preamplifiers are demonstrated. A benefit of this approach is the ability to independently acquire fundamental and multiple harmonic signals in parallel using the same ions under identical conditions, enabling direct comparison of achieved performance as parameters are varied. Spectra from harmonic signals showed generally higher resolving power than spectra acquired with fundamental signals and equal signal duration. In addition, the maximum observed signal to noise (S/N) ratio from harmonic signals exceeded that of fundamental signals by 50 to 100%. Finally, parallel detection of fundamental and harmonic signals enables deconvolution of overlapping harmonic signals since observed fundamental frequencies can be used to unambiguously calculate all possible harmonic frequencies. Thus, the present application of parallel fundamental and harmonic signal acquisition offers a general approach to improve utilization of harmonic signals to yield high-resolution spectra with decreased acquisition time. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA.
| |
Collapse
|
6
|
Shaw JB, Gorshkov MV, Wu Q, Paša-Tolić L. High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS. Anal Chem 2018; 90:5557-5562. [PMID: 29613776 DOI: 10.1021/acs.analchem.7b04606] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultrahigh resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g., proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers such as Orbitrap and ion cyclotron resonance (FTICR-MS), with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of spectra with ultrahigh resolving power. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4× greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW = 78 kDa) and monoclonal antibody (MW = 150 kDa) were isotopically resolved with detection periods of 384 and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time scales compatible with online separations.
Collapse
Affiliation(s)
- Jared B Shaw
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| | - Mikhail V Gorshkov
- V.L. Talrose Institute for Energy Problems of Chemical Physics , Russian Academy of Sciences , Moscow 119334 , Russia.,Moscow Institute of Physics and Technology (State University) , Dolgoprudny , Moscow Region 141700 , Russia
| | - Qinghao Wu
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| | - Ljiljana Paša-Tolić
- Environmental Molecular Sciences Laboratory , Pacific Northwest National Laboratory , 3335 Innovation Boulevard . Richland , Washington 99352 , United States
| |
Collapse
|
7
|
Park SG, Anderson GA, Bruce JE. Parallel detection in a single ICR cell: Spectral averaging and improved S/N without increased acquisition time. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2018; 427:29-34. [PMID: 29731686 PMCID: PMC5931402 DOI: 10.1016/j.ijms.2017.08.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is well-renowned for its ultrahigh resolving power and mass measurement accuracy. As with other types of analytical instrumentation, achievable signal-to-noise ratio (S/N) is an important analytical figure of merit with FTICR-MS. S/N can be improved with higher magnetic fields and longer time-domain signal acquisition periods. However, serial signal averaging of spectra or time-domain signals acquired with multiple ion populations is most commonly used to improve S/N. On the other hand, serial acquisition and averaging of multiple scans significantly increases required data acquisition time and is often incompatible with on-line chromatographic separations. In this study, we investigated the potential for increased S/N by averaging 4 spectra that were acquired in parallel with a single ICR cell with 4 pairs of dipole detection electrodes, each with an independent pre-amplifier. This spectral averaging was achieved with no need for multiple ion accumulation events nor multiple, serial excitation and detection events. These efforts demonstrated that parallel signal acquisition with 4 detector electrode pairs produces S/N 1.76-fold higher than that from a single detection electrode pair. With parallel detection, improved S/N was achieved with no observable loss in resolving power (100,000) as compared with that from a single detection electrode pair. These results demonstrate that parallel detection of multiple induced image current signals with multiple preamplifiers exists as a viable option for future instrumentation to increase achievable S/N and sensitivity. This approach may have general utility especially where conventional serial signal averaging is impractical.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA 98109
| |
Collapse
|
8
|
Park SG, Anderson GA, Bruce JE. Parallel Spectral Acquisition with Orthogonal ICR Cells. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:515-524. [PMID: 28058592 PMCID: PMC5352489 DOI: 10.1007/s13361-016-1573-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/21/2016] [Accepted: 11/27/2016] [Indexed: 05/22/2023]
Abstract
FT-based high performance mass analyzers yield increased resolving power and mass measurement accuracy, yet require increased duration of signal acquisition that can limit many applications. The implementation of stronger magnetic fields, multiple detection electrodes for harmonic signal detection, and an array of multiple mass analyzers arranged along the magnetic field axis have been used to decrease required acquisition time. The results presented here show that multiple ion cyclotron resonance (ICR) mass analyzers can also be implemented orthogonal to the central magnetic field axis. The orthogonal ICR cell system presented here consisting of two cells (master and slave cells) was constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. A master cell was positioned, as is normally done with ICR cells, on the central magnetic field axis and a slave cell was located off this central axis, but directly adjacent and alongside the master cell. To achieve ion transfer between cells, ions that were initially trapped in the master cell were drifted across the magnetic field into the slave cell with application of a small DC field applied perpendicularly to the magnetic field axis. A subsequent population of ions was injected and accumulated in the master cell. Simultaneous excitation of cyclotron motion of ions in both cells was carried out; ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition with this orthogonal dual ICR cell array. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA
| | | | - James E Bruce
- Department of Genome Sciences, University of Washington, Seattle, WA, 98109, USA.
| |
Collapse
|
9
|
Nicolardi S, Bogdanov B, Deelder AM, Palmblad M, van der Burgt YEM. Developments in FTICR-MS and Its Potential for Body Fluid Signatures. Int J Mol Sci 2015; 16:27133-44. [PMID: 26580595 PMCID: PMC4661870 DOI: 10.3390/ijms161126012] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/03/2015] [Accepted: 11/05/2015] [Indexed: 01/01/2023] Open
Abstract
Fourier transform mass spectrometry (FTMS) is the method of choice for measurements that require ultra-high resolution. The establishment of Fourier transform ion cyclotron resonance (FTICR) MS, the availability of biomolecular ionization techniques and the introduction of the Orbitrap™ mass spectrometer have widened the number of FTMS-applications enormously. One recent example involves clinical proteomics using FTICR-MS to discover and validate protein biomarker signatures in body fluids such as serum or plasma. These biological samples are highly complex in terms of the type and number of components, their concentration range, and the structural identity of each species, and thus require extensive sample cleanup and chromatographic separation procedures. Clearly, such an elaborate and multi-step sample preparation process hampers high-throughput analysis of large clinical cohorts. A final MS read-out at ultra-high resolution enables the analysis of a more complex sample and can thus simplify upfront fractionations. To this end, FTICR-MS offers superior ultra-high resolving power with accurate and precise mass-to-charge ratio (m/z) measurement of a high number of peptides and small proteins (up to 20 kDa) at isotopic resolution over a wide mass range, and furthermore includes a wide variety of fragmentation strategies to characterize protein sequence and structure, including post-translational modifications (PTMs). In our laboratory, we have successfully applied FTICR “next-generation” peptide profiles with the purpose of cancer disease classifications. Here we will review a number of developments and innovations in FTICR-MS that have resulted in robust and routine procedures aiming for ultra-high resolution signatures of clinical samples, exemplified with state-of-the-art examples for serum and saliva.
Collapse
Affiliation(s)
- Simone Nicolardi
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Bogdan Bogdanov
- Perkin Elmer, San Jose Technology Center, San Jose, CA 95134, USA.
| | - André M Deelder
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Magnus Palmblad
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| | - Yuri E M van der Burgt
- Center for Proteomics and Metabolomics, Leiden University Medical Center (LUMC), PO Box 9600, 2300 RC Leiden, The Netherlands.
| |
Collapse
|
10
|
Affiliation(s)
- Feng Xian
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
| | - Christopher L. Hendrickson
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, 1800
East Paul Dirac Drive, Tallahassee, Florida 32310-4005, United States
| | - Alan G. Marshall
- Department
of Chemistry and
Biochemistry, Florida State University,
95 Chieftain Way, Tallahassee, Florida 32310-4390, United States
- Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, 1800
East Paul Dirac Drive, Tallahassee, Florida 32310-4005, United States
| |
Collapse
|
11
|
Lin TY, Green RJ, O'Connor PB. A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2011; 82:124101. [PMID: 22225232 PMCID: PMC3253747 DOI: 10.1063/1.3660778] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2011] [Accepted: 10/20/2011] [Indexed: 05/31/2023]
Abstract
The nature of the ion signal from a 12-T Fourier-transform ion cyclotron resonance mass spectrometer and the electronic noise were studied to further understand the electronic detection limit. At minimal cost, a new transimpedance preamplifier was designed, computer simulated, built, and tested. The preamplifier design pushes the electronic signal-to-noise performance at room temperature to the limit, because of its enhanced tolerance of the capacitance of the detection device, lower intrinsic noise, and larger flat mid-band gain (input current noise spectral density of around 1 pA/√Hz when the transimpedance is about 85 dBΩ). The designed preamplifier has a bandwidth of ~3 kHz to 10 MHz, which corresponds to the mass-to-charge ratio, m/z, of approximately 18 to 61 k at 12 T. The transimpedance and the bandwidth can be easily adjusted by changing the value of passive components. The feedback limitation of the circuit is discussed. With the maximum possible transimpedance of 5.3 MΩ when using an 0402 surface mount resistor, the preamplifier was estimated to be able to detect ~110 charges in a single scan.
Collapse
Affiliation(s)
- Tzu-Yung Lin
- School of Engineering, University of Warwick, Coventry, United Kingdom
| | | | | |
Collapse
|
12
|
Tolmachev AV, Robinson EW, Wu S, Smith RD, Paša-Toli L. Trapping radial electric field optimization in compensated FTICR cells. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2011; 22:1334-1342. [PMID: 21953187 DOI: 10.1007/s13361-011-0167-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2011] [Revised: 05/09/2011] [Accepted: 05/10/2011] [Indexed: 05/31/2023]
Abstract
Herein, we present the theoretical and experimental study of the recently introduced FTICR cell designs. We developed an approach that determines the electric field inside the cell, based on the measurement of calibration coefficients as a function of post-excitation radius and other conditions. Using the radial electric field divided by radius (E(r)/r) as a criterion of the cell harmonization, we compare the compensated cell approach with alternative designs and discuss practical implications of the cell compensation.
Collapse
Affiliation(s)
- Aleksey V Tolmachev
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, USA
| | | | | | | | | |
Collapse
|