1
|
Hwang H, Park KH, Kwon JL, Park HO, Kim J. Analysis of Self-Assembled Micelle Inhibitory RNA (SAMiRNA) Drug Using Ion-Pairing Reversed-Phase Liquid Chromatography Combined with Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1301-1309. [PMID: 38657000 DOI: 10.1021/jasms.4c00081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Small interfering RNA (siRNA) is known for its ability to silence the expression of specific genes, demonstrating its promising potential as a therapeutic approach. Self-assembled micelle inhibitory RNA (SAMiRNA) is an oligonucleotide duplex developed to overcome the in vivo delivery limitations of siRNA. SAMiRNA has hydrophilic and hydrophobic groups at both ends of a sense strand, forming a spherical nanostructure that enhances the in vivo delivery efficiency. Ion-pairing reversed-phase liquid chromatography (IP-RPLC) is the most commonly used method for the analysis of oligonucleotides. Since SAMiRNA is heavily chemically modified, the behavior of SAMiRNA in IP-RPLC combined with mass spectrometry (MS) is anticipated to differ from that of the conventional siRNA drug. The current investigation using IP-RPLC-MS revealed that a distinct duplex peak along with two minor separate strands of antisense and sense was observed at column temperatures below 35 °C in the IP-RPLC system with a 100 mM ammonium bicarbonate buffer system. At column temperatures higher than 35 °C, however, two fully denatured single strands were observed. The mass spectrum from the chromatographic peak of the SAMiRNA duplex contained signals from the duplex, the antisense, and the sense, probably due to duplex denaturation during the MS ionization process. The current comprehensive analysis results will make a substantial contribution to the future application of IP-RPLC-MS in the analysis of SAMiRNA.
Collapse
Affiliation(s)
- Hyojin Hwang
- Department of Chemistry, Chungnam National University, Daejeon 34134, Republic of Korea
| | - Kyu H Park
- Bioneer Corporation, Daejeon 34013, Republic of Korea
| | - Ju-Lee Kwon
- siRNAgen Therapeutics Inc., Daejeon 34302, Republic of Korea
| | - Han-Oh Park
- Bioneer Corporation, Daejeon 34013, Republic of Korea
- siRNAgen Therapeutics Inc., Daejeon 34302, Republic of Korea
| | - Jeongkwon Kim
- Department of Chemistry, Chungnam National University, Daejeon 34134, Republic of Korea
| |
Collapse
|
2
|
Wei B, Wang J, Dai L, Chen B, Zhang K. Characterization of synthetic guide ribonucleic acids through hydrophilic interaction chromatography coupled with mass spectrometry. J Chromatogr A 2023; 1710:464414. [PMID: 37806043 DOI: 10.1016/j.chroma.2023.464414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 09/22/2023] [Accepted: 09/24/2023] [Indexed: 10/10/2023]
Abstract
In this study, we aimed to develop a hydrophilic interaction liquid chromatography (HILIC) method for the analysis of single guide ribonucleic acid (sgRNA), a critical reagent used in CRISPR genome editing. Our results showed that effective profiling of sgRNA can be achieved by suppressing the surface charge of the stationary phase in HILIC. We identified hydrogen bonding as the primary retention mechanism with potential weak partitioning in HILIC separation of large oligonucleotides like 100-mer sgRNA. Moreover, we demonstrated that direct coupling of HILIC with mass spectrometry (MS) allows the intact mass analysis of sgRNA and its impurities with minimal adduct present. Finally, we characterized the post peak shown in the low temperature HILIC and identified it as sgRNA aggregates. Our findings provide valuable insight into the characterization of sgRNA and highlight the potential of HILIC-MS as a powerful analytical tool for relatively large oligonucleotide analysis.
Collapse
Affiliation(s)
- Bingchuan Wei
- Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, United States of America.
| | - Jenny Wang
- Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, United States of America
| | - Lulu Dai
- Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, United States of America
| | - Bifan Chen
- Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, United States of America
| | - Kelly Zhang
- Synthetic Molecule Analytical Chemistry, Genentech Inc., 1 DNA Way, South San Francisco, CA 94080, United States of America.
| |
Collapse
|
3
|
Kadlecová Z, Kalíková K, Tesařová E, Gilar M. Phosphorothioate oligonucleotides separation in ion-pairing reversed-phase liquid chromatography: effect of temperature. J Chromatogr A 2022; 1681:463473. [PMID: 36113338 DOI: 10.1016/j.chroma.2022.463473] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/27/2022] [Accepted: 09/01/2022] [Indexed: 11/15/2022]
Abstract
Analysis of diastereomers of phosphorothioate oligonucleotides in ion-pairing reversed-phase liquid chromatography is affected not only by the character and concentration of ion-pairing system, but also by the separation temperature. In this work, eight ion-pairing systems at two concentrations buffered with acetic acid were used with octadecyl column to investigate the effects of temperature (in the range from 20 °C to 90 °C) on retention, diastereomeric separation, resolution of mers of different length and resolution of oligonucleotides with different number of phosphorothioate linkages. It was observed that elevated temperature suppresses the diastereomeric separation and oligonucleotide peaks become narrower. This improves the resolution of n and n-1 mers at elevated temperature. Plots of ln k (k = retention factor) versus reciprocal absolute temperature show that for 100 mM ion-pairing systems the increase in temperature does not lead to simple decrease in oligonucleotides retention as generally observed in reversed-phase liquid chromatography. The aim of this work is to improve chromatographic method for analysis of phosphorothioate oligonucleotides.
Collapse
Affiliation(s)
- Zuzana Kadlecová
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic
| | - Květa Kalíková
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic.
| | - Eva Tesařová
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Hlavova 8, 12800, Prague, Czech Republic
| | - Martin Gilar
- Waters Corporation, 34 Maple Street, Milford, MA 01757, United States of America.
| |
Collapse
|
4
|
Oligonucleotides Isolation and Separation—A Review on Adsorbent Selection. Int J Mol Sci 2022; 23:ijms23179546. [PMID: 36076941 PMCID: PMC9455468 DOI: 10.3390/ijms23179546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 11/24/2022] Open
Abstract
Oligonucleotides have many important applications, including as primers in polymerase chain reactions and probes for DNA sequencing. They are proposed as a diagnostic and prognostic tool for various diseases and therapeutics in antisense therapy. Accordingly, it is necessary to develop liquid chromatography and solid phase extraction methods to separate oligonucleotides and isolate them from biological samples. Many reviews have been written about the determination of these compounds using the separation technique or sample preparation for their isolation. However, presumably, there are no articles that critically review the adsorbents used in liquid chromatography or solid phase extraction. The present publication reviews the literature from the last twenty years related to supports (silica, polymers, magnetic nanoparticles) and their modifications. The discussed issues concern reversed phase (alkyl, aromatic, cholesterol, mixed ligands), ion-exchange (strong and weak ones), polar (silica, polyhydroxy, amide, zwitterionic), and oligonucleotide-based adsorbents.
Collapse
|
5
|
Lardeux H, Goyon A, Zhang K, Nguyen JM, Lauber MA, Guillarme D, D'Atri V. The impact of low adsorption surfaces for the analysis of DNA and RNA oligonucleotides. J Chromatogr A 2022; 1677:463324. [PMID: 35858489 DOI: 10.1016/j.chroma.2022.463324] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 12/20/2022]
Abstract
As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.
Collapse
Affiliation(s)
- Honorine Lardeux
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Alexandre Goyon
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | - Kelly Zhang
- Small Molecule Pharmaceutical Sciences, Genentech Inc., DNA Way, South San Francisco, CA 94080, USA
| | | | | | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland
| | - Valentina D'Atri
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, Geneva 4 1211, Switzerland.
| |
Collapse
|
6
|
Abdullah AM, Sommers C, Hawes J, Rodriguez JD, Yang K. Tandem mass spectrometric sequence characterization of synthetic thymidine-rich oligonucleotides. JOURNAL OF MASS SPECTROMETRY : JMS 2022; 57:e4819. [PMID: 35347805 PMCID: PMC9287059 DOI: 10.1002/jms.4819] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 02/25/2022] [Accepted: 03/04/2022] [Indexed: 05/30/2023]
Abstract
Tandem mass spectrometry (MS/MS) can provide direct and accurate sequence characterization of synthetic oligonucleotide drugs, including modified oligonucleotides. Multiple factors can affect oligonucleotide MS/MS sequencing, including the intrinsic properties of oligonucleotides (i.e., nucleotide composition and structural modifications) and instrument parameters associated with the ion activation for fragmentation. In this study, MS/MS sequencing of a thymidine (T)-rich and phosphorothioate (PS)-modified DNA oligonucleotide was investigated using two fragmentation techniques: trap-type collision-induced dissociation ("CID") and beam-type CID also termed as higher-energy collisional dissociation ("HCD"), preceded by a hydrophilic interaction liquid chromatography (HILIC) separation. A low to moderate charge state (-4), which predominated under the optimized HILIC-MS conditions, was selected as the precursor ion for MS/MS analysis. Comparison of the two distinctive ion activation mechanisms on the same precursor demonstrated that HCD was superior to CID in promoting higher sequence coverage and analytical sensitivity in sequence elucidation of T-rich DNA oligonucleotides. Specifically, HCD provided more sequence-defining fragments with higher fragment intensities than CID. Furthermore, the direct comparison between unmodified and PS-modified DNA oligonucleotides demonstrated a loss of MS/MS fragmentation efficiency by PS modification in both CID and HCD approaches, and a resultant reduction in sequence coverage. The deficiency in PS DNA sequence coverage observed with single collision energy HCD, however, was partially recovered by applying HCD with multiple collision energies. Collectively, this work demonstrated that HCD is advantageous to MS/MS sequencing of T-rich PS-modified DNA oligonucleotides.
Collapse
Affiliation(s)
- A. M. Abdullah
- Division of Complex Drug Analysis, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and ResearchU.S. Food and Drug AdministrationSaint LouisMissouriUSA
| | - Cynthia Sommers
- Division of Complex Drug Analysis, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and ResearchU.S. Food and Drug AdministrationSaint LouisMissouriUSA
| | - Jessica Hawes
- Division of Systems Biology, National Center for Toxicological ResearchU.S. Food and Drug AdministrationJeffersonArkansasUSA
| | - Jason D. Rodriguez
- Division of Complex Drug Analysis, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and ResearchU.S. Food and Drug AdministrationSaint LouisMissouriUSA
| | - Kui Yang
- Division of Complex Drug Analysis, Office of Testing and Research, Office of Pharmaceutical Quality, Center for Drug Evaluation and ResearchU.S. Food and Drug AdministrationSaint LouisMissouriUSA
| |
Collapse
|
7
|
Sutton JM, Kim J, El Zahar NM, Bartlett MG. BIOANALYSIS AND BIOTRANSFORMATION OF OLIGONUCLEOTIDE THERAPEUTICS BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY. MASS SPECTROMETRY REVIEWS 2021; 40:334-358. [PMID: 32588492 DOI: 10.1002/mas.21641] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 05/05/2020] [Accepted: 05/28/2020] [Indexed: 06/11/2023]
Abstract
Since 2016, eight new oligonucleotide therapies have been approved which has led to increased interest in oligonucleotide analysis. There is a particular need for powerful bioanalytical tools to study the metabolism and biotransformation of these molecules. This review provides the background on the biological basis of these molecules as currently used in therapies. The article also reviews the current state of analytical methodology including state of the art sample preparation techniques, liquid chromatography-mass spectrometry methods, and the current limits of detection/quantitation. Finally, the article summarizes the challenges in oligonucleotide bioanalysis and provides future perspectives for this emerging field. © 2020 John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- James Michael Sutton
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Jaeah Kim
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| | - Noha M El Zahar
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Cairo, 11566, Egypt
| | - Michael G Bartlett
- Department of Pharmaceutical and Biomedical Sciences, College of Pharmacy, University of Georgia, 250 West Green Street, Athens, GA, 30602-2352
| |
Collapse
|
8
|
Huang M, Xu X, Qiu H, Li N. Analytical characterization of DNA and RNA oligonucleotides by hydrophilic interaction liquid chromatography-tandem mass spectrometry. J Chromatogr A 2021; 1648:462184. [PMID: 33991753 DOI: 10.1016/j.chroma.2021.462184] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 03/28/2021] [Accepted: 04/18/2021] [Indexed: 01/06/2023]
Abstract
Liquid chromatography-mass spectrometry has been widely implemented as a powerful tool for providing in-depth characterization of nucleic acid therapeutic modalities, such as anti-sense oligonucleotides and small interfering RNAs (siRNAs). In this study, we developed a generic hydrophilic interaction liquid chromatography (HILIC) hyphenated with tandem mass spectrometry method in the absence of ion-pairing reagents and demonstrated its capability as an attractive and robust alternative for oligonucleotide and siRNA analysis. HILIC separation of mixtures of unmodified and fully phosphorothioate-modified DNA oligonucleotides and their synthetic 3' exonuclease-digested metabolites were also assessed. High-resolution mass spectrometric (HRMS) analysis was used to determine the deconvoluted masses of oligonucleotide and siRNA standards and their impurities. To enable unbiased sequence characterization with tandem mass spectrometry (MS/MS), we also optimized higher-energy C-trap dissociation (HCD) on improving the sequence coverage of DNA and RNA oligonucleotides. Lastly, we evaluated on-column sensitivity for a phosphorothioate oligonucleotide by performing targeted analysis with either targeted selected ion monitoring (tSIM) or parallel reaction monitoring (PRM). Higher on-column sensitivity of 13 ng, equivalent to 2.0 pmol, of a phosphorothioate oligonucleotide was achieved by tSIM analysis as compared to PRM analysis.
Collapse
Affiliation(s)
- Ming Huang
- Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591, USA
| | - Xiaobin Xu
- Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591, USA.
| | - Haibo Qiu
- Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591, USA.
| | - Ning Li
- Regeneron Pharmaceuticals Inc., Tarrytown, NY 10591, USA
| |
Collapse
|
9
|
Nuckowski Ł, Kilanowska A, Studzińska S. Hydrophilic interaction in solid-phase extraction of antisense oligonucleotides. J Chromatogr Sci 2021; 58:383-387. [PMID: 32043121 DOI: 10.1093/chromsci/bmz114] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 09/12/2019] [Accepted: 11/13/2019] [Indexed: 11/13/2022]
Abstract
The presented studies aimed to develop a new and simple extraction method based on hydrophilic interaction for antisense oligonucleotides with different modifications. For this purpose, solid-phase extraction cartridges with unmodified silica were used. All extraction steps were performed by utilizing water, acetonitrile, acetone or their mixtures. The results obtained show that a high content (95%) of organic solvent, used during sample loading, is critical to achieve a successful extraction, while elution with pure water allows effective oligonucleotides desorption. The recovery values were greater than 90% in the case of unmodified DNA, phosphorothioate, 2'-O-(2-methoxyethyl) and 2'-O-methyl oligonucleotides. For the mixture of phosphorothioate oligonucleotide and its two synthetic metabolites, the recovery values for the standard solutions were in the range of 70-75%, while for spiked human plasma, 45-50%. The developed method is simple, may be performed in a short time and requires simple solvents like water or acetonitrile/acetone, thus showing promise as an alternative to chaotropic salt-based or ion pair-based SPE methods.
Collapse
Affiliation(s)
- Łukasz Nuckowski
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin St., PL-87-100 Toruń, Poland
| | - Anna Kilanowska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin St., PL-87-100 Toruń, Poland
| | - Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin St., PL-87-100 Toruń, Poland
| |
Collapse
|
10
|
Santos IC, Brodbelt JS. Recent developments in the characterization of nucleic acids by liquid chromatography, capillary electrophoresis, ion mobility, and mass spectrometry (2010-2020). J Sep Sci 2021; 44:340-372. [PMID: 32974962 PMCID: PMC8378248 DOI: 10.1002/jssc.202000833] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 09/18/2020] [Accepted: 09/21/2020] [Indexed: 12/25/2022]
Abstract
The development of new strategies for the analysis of nucleic acids has gained momentum due to the increased interest in using these biomolecules as drugs or drug targets. The application of new mass spectrometry ion activation techniques and the optimization of separation methods including liquid chromatography, capillary electrophoresis, and ion mobility have allowed more detailed characterization of nucleic acids and oligonucleotide therapeutics including confirmation of sequence, localization of modifications and interaction sites, and structural analysis as well as identification of failed sequences and degradation products. This review will cover tandem mass spectrometry methods as well as the recent developments in liquid chromatography, capillary electrophoresis, and ion mobility coupled to mass spectrometry for the analysis of nucleic acids and oligonucleotides.
Collapse
Affiliation(s)
- Inês C Santos
- Department of Chemistry, University of Texas at Austin, Austin, Texas, USA
| | | |
Collapse
|
11
|
Vásconez J, Pero-Gascon R, Giménez E, Benavente F. Comparison of capillary electrophoresis and zwitterionic-hydrophilic interaction capillary liquid chromatography with ultraviolet and mass spectrometry detection for the analysis of microRNA biomarkers. Talanta 2020; 219:121263. [PMID: 32887154 DOI: 10.1016/j.talanta.2020.121263] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 06/03/2020] [Accepted: 06/04/2020] [Indexed: 12/17/2022]
Abstract
This study evaluates zwitterionic-hydrophilic interaction capillary liquid chromatography (capZIC-HILIC) and capillary electrophoresis (CE) with ultraviolet (UV) and mass spectrometry (MS) detection for the direct, label-free and multiplex analysis of microribonucleic acids (miRNAs). CapZIC-HILIC-UV and CE-UV methods were first optimized, resulting in similar separations for a mixture of three miRNAs (hsa-iso-miR-16-5p, hsa-let-7g-5p, and hsa-miR-21-5p) but with reversal of elution/migration orders and small differences in repeatability, linearity, limit of detection (LOD) and separation efficiency. The established UV methods were transferred and validated in these terms with mass spectrometry (MS) detection, which allowed identifying the miRNAs and characterizing their post-transcriptional modifications. LOD by capZIC-HILIC-MS was 1 μM of miRNA, around 5 times lower than by CE-MS due to the analyte dilution with the sheathflow CE-MS interface and to the slightly increased abundance of alkali metals adducts in the CE-MS mass spectra. In addition, the suction effect promoted by the nebulizer gas in CE-MS negatively affected the already compromised separations. In contrast, CE-MS showed superior repeatabilities with spiked serum samples, as well as reduced costs, extended capillary column durabilities and shorter conditioning times. The comparison of the different methods allows disclosing the current advantages and disadvantages of capZIC-HILIC and CE for the analysis of miRNA biomarkers.
Collapse
Affiliation(s)
- Jeanneth Vásconez
- Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028, Barcelona, Spain
| | - Roger Pero-Gascon
- Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028, Barcelona, Spain
| | - Estela Giménez
- Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028, Barcelona, Spain
| | - Fernando Benavente
- Department of Chemical Engineering and Analytical Chemistry, Institute for Research on Nutrition and Food Safety (INSA·UB), University of Barcelona, 08028, Barcelona, Spain.
| |
Collapse
|
12
|
Maekawa Y, Yamazaki K, Ihara M, Nagase K, Kanazawa H. Simultaneous analysis of multiple oligonucleotides by temperature-responsive chromatography using a poly(N-isopropylacrylamide)-based stationary phase. Anal Bioanal Chem 2020; 412:5341-5351. [PMID: 32529301 PMCID: PMC7387324 DOI: 10.1007/s00216-020-02749-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 05/21/2020] [Accepted: 05/29/2020] [Indexed: 12/25/2022]
Abstract
Oligonucleotide therapeutics have contributed remarkably to healthcare, being well suited for the treatment of intractable diseases that are difficult to approach using conventional drug modalities. However, as common techniques of oligonucleotide analysis rely on reversed-phase or ion-exchange liquid chromatography and thus employ toxic organic solvents and/or ion-pairing reagents, better alternatives are highly sought after. Poly(N-isopropylacrylamide) (PNIPAAm) is widely used in temperature-responsive chromatography (TRC), which relies on column temperature variation to control the physical properties of the stationary phase and, unlike conventional reversed-phase liquid chromatography, avoids the use of toxic organic solvents and complicated gradient methods. Herein, PNIPAAm copolymer hydrogel-modified silica beads were used for the simultaneous analysis of multiple synthetic oligonucleotides by TRC to recognize differences in the length of single nucleotides, single bases, and the number of phosphorothioated sites. Temperature-responsive elution was observed in all cases. Each separation of all combinations of multiple oligonucleotides was better at higher temperatures above the lower critical solution temperature and was performed without the use of organic solvents and gradient methods. In the case of multiply phosphorothioated oligonucleotides, good separation was achieved using an aqueous solvent and isocratic elution in the absence of ion-pairing reagents. Thus, the developed procedure was concluded to be well suited for oligonucleotide analysis. Graphical abstract ![]()
Collapse
Affiliation(s)
- Yutaro Maekawa
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Minato-ku, Tokyo, 105-8512, Japan
| | - Kaichi Yamazaki
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Minato-ku, Tokyo, 105-8512, Japan
| | - Miwa Ihara
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Minato-ku, Tokyo, 105-8512, Japan
| | - Kenichi Nagase
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Minato-ku, Tokyo, 105-8512, Japan
| | - Hideko Kanazawa
- Faculty of Pharmacy, Keio University, 1-5-30, Shibakoen, Minato-ku, Tokyo, 105-8512, Japan.
| |
Collapse
|
13
|
Catani M, De Luca C, Medeiros Garcia Alcântara J, Manfredini N, Perrone D, Marchesi E, Weldon R, Müller-Späth T, Cavazzini A, Morbidelli M, Sponchioni M. Oligonucleotides: Current Trends and Innovative Applications in the Synthesis, Characterization, and Purification. Biotechnol J 2020; 15:e1900226. [PMID: 32298041 DOI: 10.1002/biot.201900226] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 03/17/2020] [Indexed: 12/12/2022]
Abstract
Oligonucleotides (ONs) are gaining increasing importance as a promising novel class of biopharmaceuticals. Thanks to their fundamental role in gene regulation, they can be used to develop custom-made drugs (also called N-to-1) able to act on the gene expression at pre-translational level. With recent approvals of ON-based therapeutics by the Food and Drug Administration (FDA), a growing demand for high-quality chemically modified ONs is emerging and their market is expected to impressively prosper in the near future. To satisfy this growing market demand, a scalable and economically sustainable ON production is needed. In this paper, the state of the art of the whole ON production process is illustrated with the aim of highlighting the most promising routes toward the auspicated market-size production. In particular, the most recent advancements in both the upstream stage, mainly based on solid-phase synthesis and recombinant technology, and the downstream one, focusing on chromatographic techniques, are reviewed. Since ON production is projected to expand to the large scale, automatized multicolumn countercurrent technologies will reasonably be required soon to replace the current ones based on batch single-column operations. This consideration is supported by a recent cutting-edge application of continuous chromatography for the ON purification.
Collapse
Affiliation(s)
- Martina Catani
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara, via L. Borsari 46, Ferrara, 44121, Italy
| | - Chiara De Luca
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara, via L. Borsari 46, Ferrara, 44121, Italy
| | - João Medeiros Garcia Alcântara
- Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, via Mancinelli 7, Milano, 20131, Italy
| | - Nicolò Manfredini
- Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, via Mancinelli 7, Milano, 20131, Italy
| | - Daniela Perrone
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara, via L. Borsari 46, Ferrara, 44121, Italy
| | - Elena Marchesi
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara, via L. Borsari 46, Ferrara, 44121, Italy
| | - Richard Weldon
- ChromaCon AG, Technoparkstrasse 1, Zürich, 8005, Switzerland
| | | | - Alberto Cavazzini
- Department of Chemistry and Pharmaceutical Sciences, University of Ferrara, via L. Borsari 46, Ferrara, 44121, Italy
| | - Massimo Morbidelli
- Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, via Mancinelli 7, Milano, 20131, Italy
| | - Mattia Sponchioni
- Department of Chemistry, Materials and Chemical Engineering "Giulio Natta,", Politecnico di Milano, via Mancinelli 7, Milano, 20131, Italy
| |
Collapse
|
14
|
Application of hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry for the retention and sensitivity studies of antisense oligonucleotides. J Chromatogr A 2020; 1622:461100. [PMID: 32359780 DOI: 10.1016/j.chroma.2020.461100] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 11/20/2022]
Abstract
The aim of the present investigation was application of hydrophilic interaction liquid chromatography as an alternative chromatographic approach for the study of antisense oligonucleotides. The influence of several mobile phases, differing with the salt type, their concentration and pH value on the retention and the separation of antisense oligonucleotides has been examined for this purpose. Four different stationary phases were also applied including unmodified silica, silica modified with the use of sulfobetaine groups, polyhydroxy and aminopropyl groups. Such wide range of tested conditions has been useful in better understanding of the retention mechanism of tested compounds. The results obtained during this investigation indicated that greater retention, greater peaks symmetry, as well as more effective separation of oligonucleotides, were obtained for the zwitterionic stationary phase. Moreover, the optimization of tandem mass spectrometry parameters with the use of Central Composite Design was performed and different mobile phases were tested to choose that one, which provided the greatest antisense oligonucleotides peak areas in Multiple Reaction Monitoring mode and consequently, the greatest possible sensitivity. Hydrophilic interaction liquid chromatography was compared with the ion pair chromatography, commonly used in the analysis of oligonucleotides. Both techniques were compared in terms of selectivity of separation as well as the sensitivity of their determination. Obtained results proved that ion pair chromatography provided better results in terms of separation efficiency and peak areas in Multiple Reaction Monitoring for tested conditions. However, these results do not preclude application of hydrophilic interaction liquid chromatography as an alternative chromatographic approach for the oligonucleotides analysis especially when a mobile phase without ion pair reagents is required.
Collapse
|
15
|
Nuckowski Ł, Kaczmarkiewicz A, Studzińska S, Buszewski B. A new approach to preparation of antisense oligonucleotide samples with microextraction by packed sorbent. Analyst 2019; 144:4622-4632. [PMID: 31245798 DOI: 10.1039/c9an00740g] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Our research focused on applying microextraction by packed sorbent to extracting antisense oligonucleotides from serum samples. The tested sorbents included poly(styrene-co-divinylbenzene), octyl, octadecyl, and unmodified silica gel. As nonpolar sorbents were used for highly-polar molecules, this required ion-pair mode. Comprehensive optimization of extraction conditions was performed for 20-mer phosphorothioate oligonucleotide. Several parametres - the number of "draw-eject" cycles during the conditioning and load step, the amine type and concentration, and the volume of elution mixture - and the influence they had on recovery were studied for nonpolar sorbents, which made it possible to obtain high (ca. 90%) recovery values. The most influential parameter turned out to be the volume of elution mixture. Similar optimization was performed for silica sorbents; however, despite optimization of various parameters, the recovery values stayed relatively low. The optimized procedures for nonpolar sorbents were applied in extraction of six different oligonucleotides of various length and with different structure modifications. The highest recoveries were obtained for octyl and octadecyl sorbents, ranging between 80-99%. The developed microextraction method was used to extract phosphorothioate and 2'-O-(2-methoxyethyl) oligonucleotides and their two synthetic metabolites from enriched human plasma, with recoveries around 70-80%.
Collapse
Affiliation(s)
- Łukasz Nuckowski
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| | - Anna Kaczmarkiewicz
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| | - Sylwia Studzińska
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| | - Bogusław Buszewski
- Chair of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarin Str., PL-87-100 Toruń, Poland.
| |
Collapse
|
16
|
Liu R, Ruan Y, Liu Z, Gong L. The role of fluoroalcohols as counter anions for ion-pairing reversed-phase liquid chromatography/high-resolution electrospray ionization mass spectrometry analysis of oligonucleotides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:697-709. [PMID: 30668892 DOI: 10.1002/rcm.8386] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 01/11/2019] [Accepted: 01/11/2019] [Indexed: 06/09/2023]
Abstract
RATIONALE Hexafluoroisopropanol (HFIP) has been widely used as a counter anion in the mobile phase for ion-pairing reversed-phase liquid chromatography/mass spectrometry (IP-RP-LC/MS) analysis of oligonucleotides. However, researchers are still searching for improvements to counter anions for LC/MS analysis of oligonucleotides. This study aimed to find alternatives to HFIP for analyzing oligonucleotides. METHODS The study was performed using an Agilent 1290 ultra-high-performance liquid chromatography (UHPLC) system coupled to an Agilent 6540 mass spectrometer by using an oligonucleotide BEH C18 column (100 × 2.1 mm, 1.7 μm). Buffer systems containing ion-pairing reagents (triethylamine, tripropylamine, hexylamine, dimethylbutylamine, diisopropylethylamine, N,N-dimethylcyclohexylamine, and octylamine) and fluoroalcohols (HFIP and hexafluoro-2-methyl-2-propanol (HFTP)) were compared chromatographically and mass spectrometrically. RESULTS Results showed that HFTP has better desalting ability than HFIP, but both HFIP and HFTP have comparable effects on the separation of oligonucleotides sized from 10mer to 40mer for most of ion-pairing reagents, with the exception of triethylamine and N,N-dimethylcyclohexylamine, where HFIP performed better than HFTP. CONCLUSIONS The choice of fluoroalcohols in IP-RP-LC/MS analysis of oligonucleotides depends on the type of ion-pairing reagents used in the mobile phase. As a guideline, we would recommend to use either HA-HFIP or HA-HFTP for small oligonucleotides, but TPA-HFTP for large oligonucleotides for IP-RP-LC/MS analysis of synthetic oligonucleotides.
Collapse
Affiliation(s)
- Rong Liu
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Yanjiao Ruan
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Zhongqiu Liu
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| | - Lingzhi Gong
- Joint Laboratory for Translational Cancer Research of Chinese Medicine of the Ministry of Education of the People's Republic of China, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
- International Institute for Translational Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong Province, 510006, PR China
| |
Collapse
|
17
|
Oligonucleotide analysis by hydrophilic interaction liquid chromatography-mass spectrometry in the absence of ion-pair reagents. J Chromatogr A 2019; 1595:39-48. [PMID: 30772056 DOI: 10.1016/j.chroma.2019.02.016] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 02/02/2019] [Accepted: 02/06/2019] [Indexed: 01/09/2023]
Abstract
Improving our understanding of nucleic acids, both in biological and synthetic applications, remains a bustling area of research for both academic and industrial laboratories. As nucleic acids research evolves, so must the analytical techniques used to characterize nucleic acids. One powerful analytical technique has been coupled liquid chromatography - tandem mass spectrometry (LC-MS/MS). To date, the most successful chromatographic mode has been ion-pairing reversed-phase liquid chromatography. Hydrophilic interaction liquid chromatography (HILIC), in the absence of ion-pair reagents, has been investigated here as an alternative chromatographic approach to the analysis of oligonucleotides. By combining a mobile phase system using commonly employed in liquid chromatography-mass spectrometry (LC-MS) - i.e., water, acetonitrile, and ammonium acetate - and a new, commercially available diol-based HILIC column, high chromatographic and mass spectrometric performance for a wide range of oligonucleotides is demonstrated. Particular applications of HILIC-MS for the analysis of deoxynucleic acid (DNA) oligomers, modified and unmodified oligoribonucleotides, and phosphorothioate DNA oligonucleotides are presented. Based on the LC-MS performance, this HILIC-based approach provides an attractive, sensitive and robust alternative to prior ion-pairing dependent methods with potential utility for both qualitative and quantitative analyses of oligonucleotides without compromising chromatographic or mass spectrometric performance.
Collapse
|