1
|
Wang Y, Fu M, Xiao W, Zhao Y, Yuan P, Zhang X, Wu W. 3D Elastomeric Stent Functionalized with Antioxidative and Perivascular Tissue Regenerative Activities Ameliorated PVT Deprivation-Induced Vein Graft Failure. Adv Healthc Mater 2023; 12:e2301247. [PMID: 37440681 DOI: 10.1002/adhm.202301247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 07/15/2023]
Abstract
Clinically, arterial injuries are always accompanied with perivascular tissue damage, which may contribute to high failure rate of vein grafts due to intimal hyperplasia and acute thrombosis. In this study, a "perivascular tissue (PVT) deprivation" animal model is constructed to mimic clinical scenarios and identify the contribution of arterial PVT to the success of vein grafts. Proteomics analysis suggests that depriving PVT may exacerbate reactive oxygen species (ROS)-induced endothelial apoptosis by up-regulating inflammation response and oxidative stress. Locally administering metformin on vein grafts through 3D-printed external stent (PGS-PCL) shows antioxidative and anti-inflammatory properties to protect cells from ROS invasion, thereafter decreasing acute thrombosis. Moreover, metformin induce rapid regeneration of perivascular adipose tissue in recipient regions, which improves patency by inhibiting intimal hyperplasia. Proteomics, western blot, and in vitro blocking tests reveal that metformin resists endothelial apoptosis through AMPK/mTOR and NFκB signaling pathways. To conclude, PVT deprivation exacerbates inflammatory response and oxidative stress in vein grafts bridging arterial circulation. Metformin-loaded stent ameliorates "PVT damage" related vein graft failure, and enhances patency of through resisting endothelial apoptosis and regenerating arterial PVAT, offering a promising avenue to improve the success of vein grafts in clinic.
Collapse
Affiliation(s)
- Yinggang Wang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Mingdi Fu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Weiwei Xiao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Yajing Zhao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Pingping Yuan
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Xinchi Zhang
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| | - Wei Wu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Oral&Maxillofacial Surgery, School of Stomatology, The Fourth Military Medical University, Xi'an, P. R. China
| |
Collapse
|
2
|
Li S, Zhao F, Tang Y, Zhang Y, Rong H, Liu L, Gao R, Liu X, Huangfu Y, Bai Y, Feng Z, Guo Z, Dong A, Wang W, Kong D, Huang P. Bioinspired, Anticoagulative, 19 F MRI-Visualizable Bilayer Hydrogel Tubes as High Patency Small-Diameter Vascular Grafts. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2302621. [PMID: 37340585 DOI: 10.1002/smll.202302621] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/29/2023] [Indexed: 06/22/2023]
Abstract
The clinical patency of small-diameter vascular grafts (SDVGs) (ID < 6 mm) is limited, with the formation of mural thrombi being a major threat of this limitation. Herein, a bilayered hydrogel tube based on the essential structure of native blood vessels is developed by optimizing the relation between vascular functions and the molecular structure of hydrogels. The inner layer of the SDVGs comprises a zwitterionic fluorinated hydrogel, avoiding the formation of thromboinflammation-induced mural thrombi. Furthermore, the position and morphology of the SDVGs can be visualized via 19 F/1 H magnetic resonance imaging. The outer poly(N-acryloyl glycinamide) hydrogel layer of SDVGs provides matched mechanical properties with native blood vessels through the multiple and controllable intermolecular hydrogen-bond interactions, which can withstand the accelerated fatigue test under pulsatile radial pressure for 380 million cycles (equal to a service life of 10 years in vivo). Consequently, the SDVGs exhibit higher patency (100%) and more stable morphology following porcine carotid artery transplantation for 9 months and rabbit carotid artery transplantation for 3 months. Therefore, such a bioinspired, antithrombotic, and visualizable SDVG presents a promising design approach for long-term patency products and great potential of helping patients with cardiovascular diseases.
Collapse
Affiliation(s)
- Shuangyang Li
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Feng Zhao
- Chest hospital, Tianjin University, Tianjin, 300222, China
| | - Yipeng Tang
- Chest hospital, Tianjin University, Tianjin, 300222, China
| | - Yiqun Zhang
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Hui Rong
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Lingyuan Liu
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Rui Gao
- Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, 300192, China
| | - Xiang Liu
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Yini Huangfu
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
| | - Yunpeng Bai
- Chest hospital, Tianjin University, Tianjin, 300222, China
| | - Zujian Feng
- Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, 300192, China
| | - Zhigang Guo
- Chest hospital, Tianjin University, Tianjin, 300222, China
| | - Anjie Dong
- Department of Polymer Science and Engineering, Key Laboratory of Systems Bioengineering (Ministry of Education), School of Chemical Engineering and Technology, Tianjin University, Tianjin, 300072, China
- Frontiers Science Center for Synthetic Biology, Key Laboratory of Systems Bioengineering(MOE), Tianjin University, Tianjin, 300072, China
| | - Weiwei Wang
- Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, 300192, China
| | - Deling Kong
- State Key Laboratory of Medicinal Chemical Biology, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Pingsheng Huang
- Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, 300192, China
| |
Collapse
|
3
|
Ha H, Park JY, Lee CH, Son D, Chung SW, Baek S, Lee K, Lee KS, Yi SW, Kang M, Kim D, Sung H. Vascular Cast to Program Antistenotic Hemodynamics and Remodeling of Vein Graft. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2204993. [PMID: 36727829 PMCID: PMC10074125 DOI: 10.1002/advs.202204993] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 12/28/2022] [Indexed: 05/31/2023]
Abstract
The structural stability of medical devices is established by managing stress distribution in response to organ movement. Veins abruptly dilate upon arterial grafting due to the mismatched tissue property, resulting in flow disturbances and consequently stenosis. Vascular cast is designed to wrap the vein-artery grafts, thereby adjusting the diameter and property mismatches by relying on the elastic fixity. Here, a small bridge connection in the cast structure serves as an essential element to prevent stress concentrations due to the improved elastic fixity. Consequently, the vein dilation is efficiently suppressed, healthy (laminar and helical) flow is induced effectively, and the heathy functions of vein grafting are promoted, as indicated by the flow directional alignment of endothelial cells with arterialization, muscle expansion, and improved contractility. Finally, collaborative effects of the bridge drastically suppress stenosis with patency improvement. As a key technical point, the advantages of the bridge addition are validated via the computational modeling of fluid-structure interaction, followed by a customized ex vivo set-up and analyses. The calculated effects are verified using a series of cell, rat, and canine models towards translation. The bridge acted like "Little Dutch boy" who saved the big mass using one finger by supporting the cast function.
Collapse
Affiliation(s)
- Hyunsu Ha
- Department of Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| | - Ju Young Park
- TMD LAB Co. Ltd.6th floor, 31, Gwangnaru‐ro 8‐gil, Seongdong‐guSeoul03722Republic of Korea
| | - Chan Hee Lee
- Department of Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| | - Deok‐Hyeon Son
- Department of Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| | - Soon Won Chung
- Department of Plastic SurgeryKorea University Guro HospitalKorea University College of MedicineGurodong‐ro 28‐gilGuro‐guSeoul08308Republic of Korea
| | - Sewoom Baek
- Department of Brain Korea 21 FOUR Project for Medical Science and Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| | - Kyubae Lee
- Department of Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| | - Kang Suk Lee
- TMD LAB Co. Ltd.6th floor, 31, Gwangnaru‐ro 8‐gil, Seongdong‐guSeoul03722Republic of Korea
| | - Se Won Yi
- TMD LAB Co. Ltd.6th floor, 31, Gwangnaru‐ro 8‐gil, Seongdong‐guSeoul03722Republic of Korea
| | - Mi‐Lan Kang
- TMD LAB Co. Ltd.6th floor, 31, Gwangnaru‐ro 8‐gil, Seongdong‐guSeoul03722Republic of Korea
| | - Dae‐Hyun Kim
- Department of Veterinary SurgeryChungnam National University College of Veterinary Medicine99, Daehak‐roYuseong‐guDaejeon34134Republic of Korea
| | - Hak‐Joon Sung
- Department of Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
- TMD LAB Co. Ltd.6th floor, 31, Gwangnaru‐ro 8‐gil, Seongdong‐guSeoul03722Republic of Korea
- Department of Brain Korea 21 FOUR Project for Medical Science and Medical EngineeringYonsei University College of Medicine50–1 Yonsei‐roSeodaemun‐guSeoul03722Republic of Korea
| |
Collapse
|
4
|
Tan W, Boodagh P, Selvakumar PP, Keyser S. Strategies to counteract adverse remodeling of vascular graft: A 3D view of current graft innovations. Front Bioeng Biotechnol 2023; 10:1097334. [PMID: 36704297 PMCID: PMC9871289 DOI: 10.3389/fbioe.2022.1097334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Accepted: 12/23/2022] [Indexed: 01/11/2023] Open
Abstract
Vascular grafts are widely used for vascular surgeries, to bypass a diseased artery or function as a vascular access for hemodialysis. Bioengineered or tissue-engineered vascular grafts have long been envisioned to take the place of bioinert synthetic grafts and even vein grafts under certain clinical circumstances. However, host responses to a graft device induce adverse remodeling, to varied degrees depending on the graft property and host's developmental and health conditions. This in turn leads to invention or failure. Herein, we have mapped out the relationship between the design constraints and outcomes for vascular grafts, by analyzing impairment factors involved in the adverse graft remodeling. Strategies to tackle these impairment factors and counteract adverse healing are then summarized by outlining the research landscape of graft innovations in three dimensions-cell technology, scaffold technology and graft translation. Such a comprehensive view of cell and scaffold technological innovations in the translational context may benefit the future advancements in vascular grafts. From this perspective, we conclude the review with recommendations for future design endeavors.
Collapse
Affiliation(s)
- Wei Tan
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States,*Correspondence: Wei Tan,
| | - Parnaz Boodagh
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
| | | | - Sean Keyser
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, United States
| |
Collapse
|
5
|
Chu T, Li Q, Dai C, Li X, Kong X, Fan Y, Yin H, Ge J. A novel Nanocellulose-Gelatin-AS-IV external stent resists EndMT by activating autophagy to prevent restenosis of grafts. Bioact Mater 2022; 22:466-481. [PMID: 36330163 PMCID: PMC9615139 DOI: 10.1016/j.bioactmat.2022.10.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 09/16/2022] [Accepted: 10/07/2022] [Indexed: 11/06/2022] Open
Abstract
Vein grafts are widely used for coronary artery bypass grafting and hemodialysis access, but restenosis remains the "Achilles' heel" of these treatments. An extravascular stent is one wrapped around the vein graft and provides mechanical strength; it can buffer high arterial pressure and secondary vascular dilation of the vein to prevent restenosis. In this study, we developed a novel Nanocellulose-gelatin hydrogel, loaded with the drug Astragaloside IV (AS-IV) as an extravascular scaffold to investigate its ability to reduce restenosis. We found that the excellent physical and chemical properties of the drug AS-IV loaded Nanocellulose-gelatin hydrogel external stent limit graft vein expansion and make the stent biocompatible. We also found it can prevent restenosis by resisting endothelial-to-mesenchymal transition (EndMT) in vitro. It does so by activating autophagy, and AS-IV can enhance this effect both in vivo and in vitro. This study has added to existing research on the mechanism of extravascular stents in preventing restenosis of grafted veins. Furthermore, we have developed a novel extravascular stent for the prevention and treatment of restenosis. This will help optimize the clinical treatment plan of external stents and improve the prognosis in patients with vein grafts. The NC-Gelatin extravascular stent has suitable physicochemical properties to prevent restenosis of the grafted veins. The NC-Gelatin extravascular stent has excellent biocompatibility, which is critical for grafting veins. The NC-Gelatin extravascular stent prevents restenosis by activating autophagy against EndMT. AS-IV can enhance the effect of the stent to activate autophagy against EndMT.
Collapse
Affiliation(s)
- Tianshu Chu
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China,Anhui Provincial Engineering Research Center for Cardiopulmonary and Vascular Materials, Hefei, Anhui, 230001, China
| | - Qingye Li
- College of Food Science, Sichuan Agricultural University, No.46, Xin Kang Road, Yaan, Sichuan Province, 625014, PR China
| | - Chun Dai
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China,Anhui Provincial Engineering Research Center for Cardiopulmonary and Vascular Materials, Hefei, Anhui, 230001, China
| | - Xiang Li
- CAS Key Laboratory of Soft Matter Chemistry, Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei, Anhui, 230026, China
| | - Xiang Kong
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China,Anhui Provincial Engineering Research Center for Cardiopulmonary and Vascular Materials, Hefei, Anhui, 230001, China
| | - Yangming Fan
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China,Anhui Provincial Engineering Research Center for Cardiopulmonary and Vascular Materials, Hefei, Anhui, 230001, China
| | - Hongyan Yin
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China
| | - Jianjun Ge
- Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China,Anhui Provincial Engineering Research Center for Cardiopulmonary and Vascular Materials, Hefei, Anhui, 230001, China,Corresponding author. The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, 230001, China.
| |
Collapse
|