1
|
Elmounedi N, Keskes H. Establishment of intervertebral disc degeneration models; A review of the currently used models. J Orthop 2024; 56:50-56. [PMID: 38784950 PMCID: PMC11109335 DOI: 10.1016/j.jor.2024.05.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 05/12/2024] [Indexed: 05/25/2024] Open
Abstract
One of the frequent causes of low back pain is intervertebral disc degeneration (IDD), which is followed by discogenic pain. Some significant risk factors that have been linked to the onset and progression of IDD include age, mechanical imbalance, changes in nutrition and inflammation. According to recent studies, five types of animal models are established for producing IDD: the spontaneous models, the puncture models, the biomechanical models, the chemical models and the hybrid models. These models are crucial in studying and understanding IDD's natural history and identifying potential treatment targets for IDD. In our study, we'll talk about the technical aspects of these models, the time between model establishment and the apparition of observable degradation, and their potential in various research. Each animal model should be compared to the human natural IDD pathogenesis to guide future research efforts in this area. By improving knowledge and appropriate application of various animal models, we seek to raise awareness of this illness and further translational research.
Collapse
Affiliation(s)
- Najah Elmounedi
- Cell Therapy and Experimental Surgery of Musculoskeletal System LR18SP1 Lab, Faculty of Medicine, Sfax, Tunisia
| | - Hassib Keskes
- Cell Therapy and Experimental Surgery of Musculoskeletal System LR18SP1 Lab, Faculty of Medicine, Sfax, Tunisia
- Department of Orthopedics and Traumatology, CHU Habib Bourguiba, Sfax, Tunisia
| |
Collapse
|
2
|
Rahman T, Kibble MJ, Harbert G, Smith N, Brewer E, Schaer TP, Newell N. Comparison of four in vitro test methods to assess nucleus pulposus replacement device expulsion risk. JOR Spine 2024; 7:e1332. [PMID: 38655007 PMCID: PMC11037461 DOI: 10.1002/jsp2.1332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 03/22/2024] [Accepted: 03/27/2024] [Indexed: 04/26/2024] Open
Abstract
Background Nucleus replacement devices (NRDs) are not routinely used in clinic, predominantly due to the risk of device expulsion. Rigorous in vitro testing may enable failure mechanisms to be identified prior to clinical trials; however, current testing standards do not specify a particular expulsion test. Multiple methods have therefore been developed, complicating comparisons between NRD designs. Thus, this study assessed the effectiveness of four previously reported expulsion testing protocols; hula-hoop (Protocol 1), adapted hula-hoop (Protocol 2), eccentric cycling (Protocol 3), and ramp to failure (Protocol 4), applied to two NRDs, one preformed and one in situ curing. Methods Nucleus material was removed from 40 bovine tail intervertebral disks. A NRD was inserted posteriorly into each cavity and the disks were subjected to one of four expulsion protocols. Results NRD response was dependent on both the NRD design and the loading protocol. Protocol 1 resulted in higher migration and earlier failure rates compared to Protocol 2 in both NRDs. The preformed NRD was more likely to migrate when protocols incorporated rotation. The NRDs had equal migration (60%) and expulsion (60%) rates when using unilateral bending and ramp testing. Combining the results of multiple tests revealed complimentary information regarding the NRD response. Conclusions Adapted hula-hoop (Protocol 2) and ramp to failure (Protocol 4), combined with fluoroscopic analysis, revealed complimentary insights regarding migration and failure risk. Therefore, when adopting the surgical approach and animal model used in this study, it is recommended that NRD performance be assessed using both a cyclic and ramp loading protocol.
Collapse
Affiliation(s)
- Tamanna Rahman
- Department of BioengineeringImperial College LondonLondonUK
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonLondonUK
| | | | | | - Nigel Smith
- Division of Surgery and Interventional ScienceUniversity College LondonStanmoreUK
| | - Erik Brewer
- Department of Biomedical EngineeringRowan UniversityGlassboroNew JerseyUSA
| | - Thomas P. Schaer
- Department of Clinical Studies New Bolton CenterUniversity of Pennsylvania School of Veterinary MedicineKennett SquarePennsylvaniaUSA
| | - Nicolas Newell
- Department of BioengineeringImperial College LondonLondonUK
| |
Collapse
|
3
|
Tang J, Luo Y, Wang Q, Wu J, Wei Y. Stimuli-Responsive Delivery Systems for Intervertebral Disc Degeneration. Int J Nanomedicine 2024; 19:4735-4757. [PMID: 38813390 PMCID: PMC11135562 DOI: 10.2147/ijn.s463939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Accepted: 05/13/2024] [Indexed: 05/31/2024] Open
Abstract
As a major cause of low back pain, intervertebral disc degeneration is an increasingly prevalent chronic disease worldwide that leads to huge annual financial losses. The intervertebral disc consists of the inner nucleus pulposus, outer annulus fibrosus, and sandwiched cartilage endplates. All these factors collectively participate in maintaining the structure and physiological functions of the disc. During the unavoidable degeneration stage, the degenerated discs are surrounded by a harsh microenvironment characterized by acidic, oxidative, inflammatory, and chaotic cytokine expression. Loss of stem cell markers, imbalance of the extracellular matrix, increase in inflammation, sensory hyperinnervation, and vascularization have been considered as the reasons for the progression of intervertebral disc degeneration. The current treatment approaches include conservative therapy and surgery, both of which have drawbacks. Novel stimuli-responsive delivery systems are more promising future therapeutic options than traditional treatments. By combining bioactive agents with specially designed hydrogels, scaffolds, microspheres, and nanoparticles, novel stimuli-responsive delivery systems can realize the targeted and sustained release of drugs, which can both reduce systematic adverse effects and maximize therapeutic efficacy. Trigger factors are categorized into internal (pH, reactive oxygen species, enzymes, etc.) and external stimuli (photo, ultrasound, magnetic, etc.) based on their intrinsic properties. This review systematically summarizes novel stimuli-responsive delivery systems for intervertebral disc degeneration, shedding new light on intervertebral disc therapy.
Collapse
Affiliation(s)
- Jianing Tang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
- First Clinic School, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
| | - Yuexin Luo
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
- First Clinic School, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
| | - Qirui Wang
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
- First Clinic School, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
| | - Juntao Wu
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
- First Clinic School, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
| | - Yulong Wei
- Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, People’s Republic of China
| |
Collapse
|
4
|
Vernengo A, Bumann H, Kluser N, Soubrier A, Šećerović A, Gewiess J, Jansen JU, Neidlinger-Wilke C, Wilke HJ, Grad S. Chemonucleolysis combined with dynamic loading for inducing degeneration in bovine caudal intervertebral discs. Front Bioeng Biotechnol 2023; 11:1178938. [PMID: 37711456 PMCID: PMC10499327 DOI: 10.3389/fbioe.2023.1178938] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 08/01/2023] [Indexed: 09/16/2023] Open
Abstract
Chemonucleolysis has become an established method of producing whole organ culture models of intervertebral disc (IVD) degeneration. However, the field needs more side-by-side comparisons of the degenerative effects of the major enzymes used in chemonucleolysis towards gaining a greater understanding of how these organ culture models mimic the wide spectrum of characteristics observed in human degeneration. In the current work we induced chemonucleolysis in bovine coccygeal IVDs with 100 µL of papain (65 U/mL), chondroitinase ABC (chABC, 5 U/mL), or collagenase II (col'ase, 0.5 U/mL). Each enzyme was applied in a concentration projected to produce moderate levels of degeneration. After 7 days of culture with daily dynamic physiological loading (0.02-0.2 MPa, 0.2 Hz, 2 h), the cellular, biochemical and histological properties of the IVDs were evaluated in comparison to a PBS-injected control. Papain and collagenase, but not chABC, produced macroscopic voids in the tissues. Compared to day 0 intact IVDs, papain induced the greatest magnitude glycosaminoglycan (GAG) loss compared to chABC and col'ase. Papain also induced the greatest height loss (3%), compared to 0.7%, 1.2% and 0.4% for chABC, col'ase, and PBS, respectively. Cell viability in the region adjacent to papain and PBS-injection remained at nearly 100% over the 7-day culture period, whereas it was reduced to 60%-70% by chABC and col'ase. Generally, enzyme treatment tended to downregulate gene expression for major ECM markers, type I collagen (COL1), type II collagen (COL2), and aggrecan (ACAN) in the tissue adjacent to injection. However, chABC treatment induced an increase in COL2 gene expression, which was significant compared to the papain treated group. In general, papain and col'ase treatment tended to recapitulate aspects of advanced IVD degeneration, whereas chABC treatment captured aspects of early-stage degeneration. Chemonucleolysis of whole bovine IVDs is a useful tool providing researchers with a robust spectrum of degenerative changes and can be utilized for examination of therapeutic interventions.
Collapse
Affiliation(s)
| | | | | | | | | | - Jan Gewiess
- AO Research Institute Davos, Davos, Switzerland
| | - Jan Ulrich Jansen
- Institute of Orthopaedic Research and Biomechanics, Ulm University, Ulm, Germany
| | | | - Hans-Joachim Wilke
- Institute of Orthopaedic Research and Biomechanics, Ulm University, Ulm, Germany
| | - Sibylle Grad
- AO Research Institute Davos, Davos, Switzerland
- Department of Health Sciences and Technology, ETH Zürich, Zurich, Switzerland
| |
Collapse
|
5
|
Lazaro-Pacheco D, Mohseni M, Rudd S, Cooper-White J, Holsgrove TP. The role of biomechanical factors in models of intervertebral disc degeneration across multiple length scales. APL Bioeng 2023; 7:021501. [PMID: 37180733 PMCID: PMC10168717 DOI: 10.1063/5.0137698] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 04/24/2023] [Indexed: 05/16/2023] Open
Abstract
Low back pain is the leading cause of disability, producing a substantial socio-economic burden on healthcare systems worldwide. Intervertebral disc (IVD) degeneration is a primary cause of lower back pain, and while regenerative therapies aimed at full functional recovery of the disc have been developed in recent years, no commercially available, approved devices or therapies for the regeneration of the IVD currently exist. In the development of these new approaches, numerous models for mechanical stimulation and preclinical assessment, including in vitro cell studies using microfluidics, ex vivo organ studies coupled with bioreactors and mechanical testing rigs, and in vivo testing in a variety of large and small animals, have emerged. These approaches have provided different capabilities, certainly improving the preclinical evaluation of these regenerative therapies, but challenges within the research environment, and compromises relating to non-representative mechanical stimulation and unrealistic test conditions, remain to be resolved. In this review, insights into the ideal characteristics of a disc model for the testing of IVD regenerative approaches are first assessed. Key learnings from in vivo, ex vivo, and in vitro IVD models under mechanical loading stimulation to date are presented alongside the merits and limitations of each model based on the physiological resemblance to the human IVD environment (biological and mechanical) as well as the possible feedback and output measurements for each approach. When moving from simplified in vitro models to ex vivo and in vivo approaches, the complexity increases resulting in less controllable models but providing a better representation of the physiological environment. Although cost, time, and ethical constraints are dependent on each approach, they escalate with the model complexity. These constraints are discussed and weighted as part of the characteristics of each model.
Collapse
Affiliation(s)
- Daniela Lazaro-Pacheco
- Department of Engineering, University of Exeter, Harrison Building, Streatham Campus, North Park Road, Exeter EX4 4QF, United Kingdom
| | - Mina Mohseni
- School of Chemical Engineering, The University of Queensland, St. Lucia QLD 4072, Australia
| | - Samuel Rudd
- School of Chemical Engineering, The University of Queensland, St. Lucia QLD 4072, Australia
| | | | - Timothy Patrick Holsgrove
- Department of Engineering, University of Exeter, Harrison Building, Streatham Campus, North Park Road, Exeter EX4 4QF, United Kingdom
| |
Collapse
|
6
|
Poletto DL, Crowley JD, Tanglay O, Walsh WR, Pelletier MH. Preclinical in vivo animal models of intervertebral disc degeneration. Part 1: A systematic review. JOR Spine 2022; 6:e1234. [PMID: 36994459 PMCID: PMC10041387 DOI: 10.1002/jsp2.1234] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 10/10/2022] [Accepted: 10/23/2022] [Indexed: 12/24/2022] Open
Abstract
Intervertebral disc degeneration (IVDD), a widely recognized cause of lower back pain, is the leading cause of disability worldwide. A myriad of preclinical in vivo animal models of IVDD have been described in the literature. There is a need for critical evaluation of these models to better inform researchers and clinicians to optimize study design and ultimately, enhance experimental outcomes. The purpose of this study was to conduct an extensive systematic literature review to report the variability of animal species, IVDD induction method, and experimental timepoints and endpoints used in in vivo IVDD preclinical research. A systematic literature review of peer-reviewed manuscripts featured on PubMed and EMBASE databases was conducted in accordance with PRISMA guidelines. Studies were included if they reported an in vivo animal model of IVDD and included details of the species used, how disc degeneration was induced, and the experimental endpoints used for analysis. Two-hundred and fifty-nine (259) studies were reviewed. The most common species, IVDD induction method and experimental endpoint used was rodents(140/259, 54.05%), surgery (168/259, 64.86%) and histology (217/259, 83.78%), respectively. Experimental timepoint varied greatly between studies, ranging from 1 week (dog and rodent models), to >104 weeks in dog, horse, monkey, rabbit, and sheep models. The two most common timepoints used across all species were 4 weeks (49 manuscripts) and 12 weeks (44 manuscripts). A comprehensive discussion of the species, methods of IVDD induction and experimental endpoints is presented. There was great variability across all categories: animal species, method of IVDD induction, timepoints and experimental endpoints. While no animal model can replicate the human scenario, the most appropriate model should be selected in line with the study objectives to optimize experimental design, outcomes and improve comparisons between studies.
Collapse
Affiliation(s)
- Daniel L. Poletto
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine University of New South Wales (UNSW) Sydney, Prince of Wales Hospital Sydney Australia
| | - James D. Crowley
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine University of New South Wales (UNSW) Sydney, Prince of Wales Hospital Sydney Australia
| | - Onur Tanglay
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine University of New South Wales (UNSW) Sydney, Prince of Wales Hospital Sydney Australia
| | - William R. Walsh
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine University of New South Wales (UNSW) Sydney, Prince of Wales Hospital Sydney Australia
| | - Matthew H. Pelletier
- Surgical and Orthopaedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine University of New South Wales (UNSW) Sydney, Prince of Wales Hospital Sydney Australia
| |
Collapse
|
7
|
Ghandour S, Pazarlis K, Lewin S, Isaksson P, Försth P, Persson C. An ex-vivo model for the biomechanical assessment of cement discoplasty. Front Bioeng Biotechnol 2022; 10:939717. [PMID: 36118564 PMCID: PMC9478659 DOI: 10.3389/fbioe.2022.939717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 07/27/2022] [Indexed: 12/05/2022] Open
Abstract
Percutaneous Cement Discoplasty (PCD) is a surgical technique developed to relieve pain in patients with advanced degenerative disc disease characterized by a vacuum phenomenon. It has been hypothesized that injecting bone cement into the disc improves the overall stability of the spinal segment. However, there is limited knowledge on the biomechanics of the spine postoperatively and a lack of models to assess the effect of PCD ex-vivo. This study aimed to develop a biomechanical model to study PCD in a repeatable and clinically relevant manner. Eleven ovine functional spinal units were dissected and tested under compression in three conditions: healthy, injured and treated. Injury was induced by a papain buffer and the treatment was conducted using PMMA cement. Each sample was scanned with micro-computed tomography (CT) and segmented for the three conditions. Similar cement volumes (in %) were injected in the ovine samples compared to volumes measured on clinical PCD CT images. Anterior and posterior disc heights decreased on average by 22.5% and 23.9% after injury. After treatment, the anterior and posterior disc height was restored on average to 98.5% and 83.6%, respectively, of their original healthy height. Compression testing showed a similar stiffness behavior between samples in the same group. A decrease of 51.5% in segment stiffness was found after injury, as expected. The following PCD treatment was found to result in a restoration of stiffness—showing only a difference of 5% in comparison to the uninjured state. The developed ex-vivo model gave an adequate representation of the clinical vacuum phenomena in terms of volume, and a repeatable mechanical response between samples. Discoplasty treatment was found to give a restoration in stiffness after injury. The data presented confirm the effectiveness of the PCD procedure in terms of restoration of axial stiffness in the spinal segment. The model can be used in the future to test more complex loading scenarios, novel materials, and different surgical techniques.
Collapse
Affiliation(s)
- Salim Ghandour
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
| | - Konstantinos Pazarlis
- Department of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden
- Stockholm Spine Center, Stockholm, Sweden
| | - Susanne Lewin
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
| | - Per Isaksson
- Division of Applied Mechanics, Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
| | - Peter Försth
- Department of Surgical Sciences, Uppsala University Hospital, Uppsala, Sweden
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Uppsala, Sweden
- *Correspondence: Cecilia Persson,
| |
Collapse
|
8
|
In-vitro models of disc degeneration - A review of methods and clinical relevance. J Biomech 2022; 142:111260. [PMID: 36027637 DOI: 10.1016/j.jbiomech.2022.111260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 07/22/2022] [Accepted: 08/11/2022] [Indexed: 11/21/2022]
Abstract
The intervertebral disc (IVD) provides flexibility, acts as a shock absorber, and transmits load. Degeneration of the IVD includes alterations in the biomechanics, extracellular matrix (ECM), and cellular activity. These changes are not always perceived, however, IVD degeneration can lead to severe health problems including long-term disability. To understand the pathogenesis of IVD degeneration and suitable testing methods for emerging treatments and therapies, this review documents in-vitro models of IVD degeneration including physical disruption, hyperphysiological loading, ECM degradation by enzyme digestion, or a combination of these methods. This paper reviews and critically analyses the models of degeneration published since the year 2000 in either in human or animal specimens. The results are categorised in terms of the IVD biomechanics, physical attributes, ECM composition, tissue damage and cellularity to evaluate the models with respect to natural human degeneration, and to provide recommendations for clinically relevant models for the various stages of degeneration. There is no one model that replicates the wide range of degenerative changes that occur as part of normal degeneration. However, cyclic overloading replicates many aspects of degeneration, with the advantage of a dose-response allowing the tuning of damage initiated. Models of severe degeneration are currently lacking, but there is potential that combining cyclic overloading and enzymatic digestion will provide model that closely resembles human IVD degeneration. This will provide an effective way to investigate the effects of severe degeneration, and the evaluation of treatments for the IVD, which would generally be indicated at this advanced stage of degeneration.
Collapse
|
9
|
Gao XD, Zhang XB, Zhang RH, Yu DC, Chen XY, Hu YC, Chen L, Zhou HY. Aggressive strategies for regenerating intervertebral discs: stimulus-responsive composite hydrogels from single to multiscale delivery systems. J Mater Chem B 2022; 10:5696-5722. [PMID: 35852563 DOI: 10.1039/d2tb01066f] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
As our research on the physiopathology of intervertebral disc degeneration (IVD degeneration, IVDD) has advanced and tissue engineering has rapidly evolved, cell-, biomolecule- and nucleic acid-based hydrogel grafting strategies have been widely investigated for their ability to overcome the harsh microenvironment of IVDD. However, such single delivery systems suffer from excessive external dimensions, difficult performance control, the need for surgical implantation, and difficulty in eliminating degradation products. Stimulus-responsive composite hydrogels have good biocompatibility and controllable mechanical properties and can undergo solution-gel phase transition under certain conditions. Their combination with ready-to-use particles to form a multiscale delivery system may be a breakthrough for regenerative IVD strategies. In this paper, we focus on summarizing the progress of research on the stimulus response mechanisms of regenerative IVD-related biomaterials and their design as macro-, micro- and nanoparticles. Finally, we discuss multi-scale delivery systems as bioinks for bio-3D printing technology for customizing personalized artificial IVDs, which promises to take IVD regenerative strategies to new heights.
Collapse
Affiliation(s)
- Xi-Dan Gao
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| | - Xiao-Bo Zhang
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiao tong University, Shaanxi 710000, P. R. China.
| | - Rui-Hao Zhang
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| | - De-Chen Yu
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| | - Xiang-Yi Chen
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| | - Yi-Cun Hu
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| | - Lang Chen
- Department of Gastrointestinal Surgery, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China
| | - Hai-Yu Zhou
- Department of Orthopaedics, Lanzhou University Second Hospital, Lanzhou, Gansu 730000, P. R. China.
| |
Collapse
|
10
|
Dixon AR, Warren JP, Culbert MP, Mengoni M, Wilcox RK. Review of in vitro mechanical testing for intervertebral disc injectable biomaterials. J Mech Behav Biomed Mater 2021; 123:104703. [PMID: 34365096 DOI: 10.1016/j.jmbbm.2021.104703] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/22/2021] [Accepted: 07/03/2021] [Indexed: 01/17/2023]
Abstract
Many early stage interventions for intervertebral disc degeneration are under development involving injection of a biomaterial into the affected tissue. Due to the complex mechanical behaviour of the intervertebral disc, there are challenges in comprehensively evaluating the performance of these injectable biomaterials in vitro. The aim of this review was to examine the different methods that have been developed to mechanically test injectable intervertebral disc biomaterials in an in vitro disc model. Testing methods were examined with emphasis on overall protocol, artificial degeneration method, mechanical testing regimes and injection delivery. Specifically, the effects of these factors on the evaluation of different aspects of device performance was assessed. Broad testing protocols varied between studies and enabled evaluation of different aspects of an injectable treatment. Studies employed artificial degeneration methodologies which were either on a macro scale through mechanical means or on a microscale with biochemical means. Mechanical loading regimes differed greatly across studies, with load being either held constant, ramped to failure, or applied cyclically, with large variability on all loading parameters. Evaluation of the risk of herniation was possible by utilising ramped loading, whereas cyclic loading enabled the examination of the restoration of mechanical behaviour for initial screening of biomaterials and surgical technique optimisation studies. However, there are large variations in the duration or tests, and further work is needed to define an appropriate number of cycles to standardise this type of testing. Biomaterial delivery was controlled by set volume or haptic feedback, and future investigations should generate evidence applying physiological loading during injection and normalisation of injection parameters based on disc size. Based on the reviewed articles and considering clinical risks, a series of recommendations have been made for future intervertebral disc mechanical testing.
Collapse
Affiliation(s)
- A R Dixon
- University of Leeds, Institute of Medical and Biological Engineering, Leeds, LS2 9JT, United Kingdom.
| | - J P Warren
- University of Leeds, Institute of Medical and Biological Engineering, Leeds, LS2 9JT, United Kingdom
| | - M P Culbert
- University of Leeds, Institute of Medical and Biological Engineering, Leeds, LS2 9JT, United Kingdom
| | - M Mengoni
- University of Leeds, Institute of Medical and Biological Engineering, Leeds, LS2 9JT, United Kingdom
| | - R K Wilcox
- University of Leeds, Institute of Medical and Biological Engineering, Leeds, LS2 9JT, United Kingdom.
| |
Collapse
|
11
|
Zhan JW, Wang SQ, Feng MS, Gao JH, Wei X, Yu J, Yin XL, Yin H, Sun K, Chen M, Xie R, Zhang P, Zhu LG. Effects of Axial Compression and Distraction on Vascular Bud and VEGFA Expression in the Vertebral Endplate of an Ex Vivo Rabbit Spinal Motion Segment Culture Model. Spine (Phila Pa 1976) 2021; 46:421-432. [PMID: 33186278 DOI: 10.1097/brs.0000000000003816] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN An ex vivo study of the rabbit's vertebral endplate. OBJECTIVE The aim of this study was to assess the effect of axial compression and distraction on vascular buds and vascular endothelial growth factor (VEGFA) expression of the vertebral endplate (VEP). SUMMARY OF BACKGROUND DATA The abnormal load can lead to intervertebral disc degeneration (IDD), whereas axial distraction can delay this process. The effects of different mechanical loads on the intervertebral disc (IVD) have been hypothesized to be related to changes in the vascular buds of the VEP; moreover, the process that might involve the vascular endothelial growth factor (VEGF) within the VEP. METHODS Rabbit spinal segments (n = 40) were harvested and randomly classified into four groups: Control group, no stress was applied; Group A, a constant compressive load applied; Group B, compression load removed for a fixed time daily on a continuous basis, and substituted with a distraction load for 30 minutes; and Group C, compression removed for 30 minutes for a fixed period daily on a continuous basis. Tissue specimens were collected before the culture (day 0) and on day 14 post-culture of each group for analysis of IVDs' morphology, and protein and mRNA expression of Aggrecan, COL2al, VEGFA, and vascular endothelial growth factor receptor 2 of the VEPs. RESULTS Application of axial distraction and dynamic load compression significantly delayed time- and constant compression-mediated VEP changes and IDD. Moreover, the degree of degeneration was associated with loss of vascular buds, as well as the downregulation of VEGFA and its receptor. CONCLUSION The regulation of vascular buds and VEGF expression in the VEP represents one of the mechanisms of axial distraction and dynamic loading.Level of Evidence: N/A.
Collapse
Affiliation(s)
- Jia-Wen Zhan
- General Orthopedics Department, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Baumgartner L, Wuertz-Kozak K, Le Maitre CL, Wignall F, Richardson SM, Hoyland J, Ruiz Wills C, González Ballester MA, Neidlin M, Alexopoulos LG, Noailly J. Multiscale Regulation of the Intervertebral Disc: Achievements in Experimental, In Silico, and Regenerative Research. Int J Mol Sci 2021; 22:E703. [PMID: 33445782 PMCID: PMC7828304 DOI: 10.3390/ijms22020703] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 12/22/2020] [Accepted: 12/24/2020] [Indexed: 12/17/2022] Open
Abstract
Intervertebral disc (IVD) degeneration is a major risk factor of low back pain. It is defined by a progressive loss of the IVD structure and functionality, leading to severe impairments with restricted treatment options due to the highly demanding mechanical exposure of the IVD. Degenerative changes in the IVD usually increase with age but at an accelerated rate in some individuals. To understand the initiation and progression of this disease, it is crucial to identify key top-down and bottom-up regulations' processes, across the cell, tissue, and organ levels, in health and disease. Owing to unremitting investigation of experimental research, the comprehension of detailed cell signaling pathways and their effect on matrix turnover significantly rose. Likewise, in silico research substantially contributed to a holistic understanding of spatiotemporal effects and complex, multifactorial interactions within the IVD. Together with important achievements in the research of biomaterials, manifold promising approaches for regenerative treatment options were presented over the last years. This review provides an integrative analysis of the current knowledge about (1) the multiscale function and regulation of the IVD in health and disease, (2) the possible regenerative strategies, and (3) the in silico models that shall eventually support the development of advanced therapies.
Collapse
Affiliation(s)
- Laura Baumgartner
- BCN MedTech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain; (L.B.); (C.R.W.); (M.A.G.B.)
| | - Karin Wuertz-Kozak
- Department of Biomedical Engineering, Rochester Institute of Technology (RIT), Rochester, NY 14623, USA;
- Schön Clinic Munich Harlaching, Spine Center, Academic Teaching Hospital and Spine Research Institute of the Paracelsus Medical University Salzburg (Austria), 81547 Munich, Germany
| | - Christine L. Le Maitre
- Biomolecular Sciences Research Centre, Sheffield Hallam University, Sheffield S1 1WB, UK;
| | - Francis Wignall
- Division of Cell Matrix Biology and Regenerative Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Sciences Centre, Oxford Road, Manchester M13 9PT, UK; (F.W.); (S.M.R.); (J.H.)
| | - Stephen M. Richardson
- Division of Cell Matrix Biology and Regenerative Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Sciences Centre, Oxford Road, Manchester M13 9PT, UK; (F.W.); (S.M.R.); (J.H.)
| | - Judith Hoyland
- Division of Cell Matrix Biology and Regenerative Medicine, School of Biological Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Sciences Centre, Oxford Road, Manchester M13 9PT, UK; (F.W.); (S.M.R.); (J.H.)
| | - Carlos Ruiz Wills
- BCN MedTech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain; (L.B.); (C.R.W.); (M.A.G.B.)
| | - Miguel A. González Ballester
- BCN MedTech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain; (L.B.); (C.R.W.); (M.A.G.B.)
- Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluis Companys 23, 08010 Barcelona, Spain
| | - Michael Neidlin
- Department of Mechanical Engineering, National Technical University of Athens, 15780 Athens, Greece; (M.N.); (L.G.A.)
| | - Leonidas G. Alexopoulos
- Department of Mechanical Engineering, National Technical University of Athens, 15780 Athens, Greece; (M.N.); (L.G.A.)
| | - Jérôme Noailly
- BCN MedTech, Department of Information and Communication Technologies, Universitat Pompeu Fabra, 08018 Barcelona, Spain; (L.B.); (C.R.W.); (M.A.G.B.)
| |
Collapse
|
13
|
Zhan JW, Wang SQ, Feng MS, Wei X, Yu J, Yin XL, Han T, Zhu LG. Constant compression decreases vascular bud and VEGFA expression in a rabbit vertebral endplate ex vivo culture model. PLoS One 2020; 15:e0234747. [PMID: 32584845 PMCID: PMC7316323 DOI: 10.1371/journal.pone.0234747] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 06/02/2020] [Indexed: 12/30/2022] Open
Abstract
SUMMARY OF BACKGROUND DATA The vascular buds in the vertebral endplate (VEP) are the structural foundation of nutrient exchange in the intervertebral disc (IVD). VEGF is closely related to angiogenesis in the endplate and intervertebral disc degeneration (IDD). OBJECTIVE To investigate the effects of static load on vascular buds and VEGF expression in the VEP and to further clarify the relation between IDD and VEGF. METHODS IVD motion segments were harvested from rabbit lumbar spines and cultured under no-loading conditions (controls) or in custom-made apparatuses under a constant compressive load (0.5 MPa) for up to 14 days. Tissue integrity and the number of vascular buds were determined, and the concentrations and expression of Aggrecan, COL2a1, and VEGFA in the VEPs were assessed after 3, 7, and 14 days of culturing and then compared with those of fresh tissues. RESULTS Under the constant compression, the morphological integrity of the VEPs was gradually disrupted, and immunohistochemistry results showed a significant decrease in the levels of Agg and COL2a1. During the static load, the number of vascular buds in the VEPs was gradually reduced from the early stage of culture, and ELISA showed that the constant compressive load caused a significant decrease in the VEGFA and VEGFR2 protein concentrations, which were consistent with the immunohistochemistry results. Western blot and RT-PCR results also showed that the loading state caused a significant decrease in VEGFA expression compared with that of fresh and control samples. CONCLUSIONS Constant compression caused degeneration of the VEP as well as a decreased number of vascular buds, thereby accelerating disc degeneration. VEGFA is involved in this process. We anticipate that regulating the expression of VEGFA may improve the condition of the lesions to the vascular buds in the endplates, thus enhancing the nutritional supply function in IVD and providing new therapeutic targets and strategies for the effective prevention and treatment of IDD.
Collapse
Affiliation(s)
- Jia-Wen Zhan
- General Orthopedics Department, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Shang-Quan Wang
- General Orthopedics Department, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Min-Shan Feng
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Xu Wei
- Scientific Research Office, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Jie Yu
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Xun-Lu Yin
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Tao Han
- General Orthopedics Department, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| | - Li-Guo Zhu
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing, China
| |
Collapse
|
14
|
Frauchiger DA, Heeb SR, May RD, Wöltje M, Benneker LM, Gantenbein B. Differentiation of MSC and annulus fibrosus cells on genetically engineered silk fleece-membrane-composites enriched for GDF-6 or TGF-β3. J Orthop Res 2018; 36:1324-1333. [PMID: 29058815 DOI: 10.1002/jor.23778] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 10/13/2017] [Indexed: 02/04/2023]
Abstract
Intervertebral disc (IVD) repair is a high-priority topic in our active and increasingly ageing society. Since a high number of people are affected by low back pain treatment options that are able to restore the biological function of the IVD are highly warranted. Here, we investigated whether the feasibility of genetically engineered (GE)-silk from Bombyx mori containing specific growth factors to precondition human bone-marrow derived mesenchymal stem cells (hMSC) or to activate differentiated human annulus fibrosus cells (hAFC) prior transplantation or for direct repair on the IVD. Here, we tested the hypothesis that GE-silk fleece can thrive human hMSC towards an IVD-like phenotype. We aimed to demonstrate a possible translational application of good manufacturing practice (GMP)-compliant GE-silk scaffolds in IVD repair and regeneration. GE-silk with growth and differentiation factor 6 (GDF-6-silk) or transforming growth factor β3 (TGF-β3, TGF-β3-silk) and untreated silk (cSilk) were investigated by DNA content, cell activity assay and glycosaminoglycan (GAG) content and their differentiation potential by qPCR analysis. We found that all silk types demonstrated a very high biocompatibility for both cell types, that is, hMSC and hAFC, as revealed by cell activity, and DNA proliferation assay. Further, analyzing qPCR of marker genes revealed a trend to differentiation toward an NP-like phenotype looking at the Aggrecan/Collagen 2 ratio which was around 10:1. Our results support the conclusion that our GE-silk scaffold treatment approach can thrive hMSC towards a more IVD-like phenotype or can maintain the phenotype of native hAFC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1324-1333, 2018.
Collapse
Affiliation(s)
- Daniela A Frauchiger
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern, Switzerland
| | - Silvan R Heeb
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern, Switzerland.,Department of Hematology and Central Hematology Laboratory, University of Bern, Inselspital, Bern University Hospital, CH-3010 Bern, Switzerland.,Department for BioMedical Research, University of Bern, CH-3010 Bern, Switzerland
| | - Rahel D May
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern, Switzerland
| | - Michael Wöltje
- Institute of Textile Machinery and High Performance Material Technology, TU Dresden, DE-01069 Dresden, Germany
| | - Lorin M Benneker
- Department of Orthopaedic Surgery and Traumatology, University of Bern, Inselspital, Bern University Hospital, CH-3010 Bern, Switzerland
| | - Benjamin Gantenbein
- Institute for Surgical Technology and Biomechanics, University of Bern, Stauffacherstrasse 78, CH-3014 Bern, Switzerland
| |
Collapse
|
15
|
Naqvi SM, Gansau J, Buckley CT. Priming and cryopreservation of microencapsulated marrow stromal cells as a strategy for intervertebral disc regeneration. ACTA ACUST UNITED AC 2018; 13:034106. [PMID: 29380742 DOI: 10.1088/1748-605x/aaab7f] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
A challenge in using stromal cells for intervertebral disc (IVD) regeneration is their limited differentiation capacity in vivo without exogenous growth factor (GF) supplementation. Priming of stromal cells prior to transplantation may offer a feasible strategy to overcome this limitation. Furthermore, the ability to cryopreserve cells could help alleviate logistical issues associated with storage and transport. With these critical translational challenges in mind, we aimed to develop a strategy involving priming and subsequent cryopreservation of microencapsulated bone marrow stromal cells (BMSCs). In phase one, we utilised the electrohydrodynamic atomisation process to fabricate BMSC-encapsulated microcapsules that were primed with TGF-β3 for 14 d after which they were cultured for a further 21 d under basal or GF supplemented media conditions. Results showed that priming induced differentiation of BMSC microcapsules such that they synthesised significant amounts of sGAG (61.9 ± 2.0 μg and 55.3 ± 6.1 μg for low and high cell densities) and collagen (24.4 ± 1.9 μg and 55.3 ± 4.6 μg for low and high cell densities) in continued culture without GF supplementation compared to Unprimed microcapsules. Phase two of this work assessed the extracellular matrix forming capacity of Primed BMSC microcapsules over 21 d after cryopreservation. Notably, primed and cryopreserved BMSCs successfully retained the ability to synthesise both sGAG (24.8 ± 2.7 μg and 75.1 ± 11.6 μg for low and high cell densities) and collagen (26.4 ± 7.8 μg and 93.1 ± 10.2 μg for low and high cell densities) post-cryopreservation. These findings demonstrate the significant potential of priming and cryopreservation approaches for IVD repair and could possibly open new horizons for pre-designed, 'off-the-shelf' injectable therapeutics.
Collapse
Affiliation(s)
- Syeda M Naqvi
- Trinity Centre for Bioengineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Ireland. School of Engineering, Trinity College Dublin, Ireland
| | | | | |
Collapse
|
16
|
Thermally triggered hydrogel injection into bovine intervertebral disc tissue explants induces differentiation of mesenchymal stem cells and restores mechanical function. Acta Biomater 2017; 54:212-226. [PMID: 28285075 DOI: 10.1016/j.actbio.2017.03.010] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Revised: 02/20/2017] [Accepted: 03/07/2017] [Indexed: 01/07/2023]
Abstract
We previously reported a synthetic Laponite® crosslinked pNIPAM-co-DMAc (L-pNIPAM-co-DMAc) hydrogel which promotes differentiation of mesenchymal stem cells (MSCs) to nucleus pulposus (NP) cells without additional growth factors. The clinical success of this hydrogel is dependent on: integration with surrounding tissue; the capacity to restore mechanical function; as well as supporting the viability and differentiation of delivered MSCs. Bovine NP tissue explants were injected with media (control), human MSCs (hMSCs) alone, acellular L-pNIPAM-co-DMAc hydrogel or hMSCs incorporated within the L-pNIPAM-co-DMAc hydrogel and maintained at 5% O2 for 6weeks. Viability of native NP cells and delivered MSCs was maintained. Furthermore hMSCs delivered via the L-pNIPAM-co-DMAc hydrogel differentiated and produced NP matrix components: aggrecan, collagen type II and chondroitin sulphate, with integration of the hydrogel with native NP tissue. In addition L-pNIPAM-co-DMAc hydrogel injected into collagenase digested bovine discs filled micro and macro fissures, were maintained within the disc during loading and restored IVD stiffness. The mechanical support of the L-pNIPAM-co-DMAc hydrogel, to restore disc height, could provide immediate symptomatic pain relief, whilst the delivery of MSCs over time regenerates the NP extracellular matrix; thus the L-pNIPAM-co-DMAc hydrogel could provide a combined cellular and mechanical repair approach. STATEMENT OF SIGNIFICANCE Low back pain (LBP) is associated with degeneration of the intervertebral disc (IVD). We have previously described development of a jelly delivery system (hydrogel). This has the potential to deliver adult stem cells to the centre of the IVD, known as the nucleus pulposus (NP). Here, we have demonstrated that adult stem cells can be safely injected into the NP using small bore needles, reducing damage to the disc. Following injection the hydrogel integrates with surrounding NP tissue, promotes differentiation of stem cells towards disc cells and restores IVD mechanical function. The hydrogel could be used to restore mechanical function to the IVD and deliver cells to promote regeneration of the disc as a minimally invasive treatment for LBP.
Collapse
|
17
|
Zhu LG, Feng MS, Zhan JW, Zhang P, Yu J. Effect of Static Load on the Nucleus Pulposus of Rabbit Intervertebral Disc Motion Segment in Ex vivo Organ Culture. Chin Med J (Engl) 2017; 129:2338-46. [PMID: 27647194 PMCID: PMC5040021 DOI: 10.4103/0366-6999.190666] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Background: The development of mechanically active culture systems helps increase the understanding of the role of mechanical stress in intervertebral disc (IVD) degeneration. Motion segment cultures allow for preservation of the native IVD structure, and adjacent vertebral bodies facilitate the application and control of mechanical loads. The purpose of this study was to establish loading and organ culture methods for rabbit IVD motion segments to study the effect of static load on the whole disc organ. Methods: IVD motion segments were harvested from rabbit lumbar spines and cultured in no-loading 6-well plates (control conditions) or custom-made apparatuses under a constant, compressive load (3 kg, 0.5 MPa) for up to 14 days. Tissue integrity, matrix synthesis, and the matrix gene expression profile were assessed after 3, 7, and 14 days of culturing and compared with those of fresh tissues. Results: The results showed that ex vivo culturing of motion segments preserved tissue integrity under no-loading conditions for 14 days whereas the static load gradually destroyed the morphology after 3 days. Proteoglycan contents were decreased under both conditions, with a more obvious decrease under static load, and proteoglycan gene expression was also downregulated. However, under static load, immunohistochemical staining intensity and collagen Type II alpha 1 (COL2A1) gene expression were significantly enhanced (61.54 ± 5.91, P = 0.035) and upregulated (1.195 ± 0.040, P = 0.000), respectively, compared with those in the controls (P < 0.05). In contrast, under constant compression, these trends were reversed. Our initial results indicated that short-term static load stimulated the synthesis of collagen Type II alpha 1; however, sustained constant compression led to progressive degeneration and specifically to a decreased proteoglycan content. Conclusions: A loading and organ culture system for ex vivo rabbit IVD motion segments was developed. Using this system, we were able to study the effects of mechanical stimulation on the biology of IVDs, as well as the pathomechanics of IVD degeneration.
Collapse
Affiliation(s)
- Li-Guo Zhu
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102; Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102, China
| | - Min-Shan Feng
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102; Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102, China
| | - Jia-Wen Zhan
- Key Laboratory of Beijing of Palasy Technology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102; General Orthopedics Department, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102, China
| | - Ping Zhang
- Department of Pathology, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102, China
| | - Jie Yu
- Spine Department 2, Wangjing Hospital, China Academy of Chinese Medical Sciences, Beijing 100102, China
| |
Collapse
|
18
|
Effect of Static Load on the Nucleus Pulposus of Rabbit Intervertebral Disc Motion Segment in an Organ Culture. BIOMED RESEARCH INTERNATIONAL 2016; 2016:2481712. [PMID: 27872846 PMCID: PMC5107879 DOI: 10.1155/2016/2481712] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/10/2016] [Revised: 08/06/2016] [Accepted: 08/21/2016] [Indexed: 01/07/2023]
Abstract
The development of mechanically active culture systems helps in understanding of the role of mechanical stress in intervertebral disc (IVD) degeneration. Motion segment cultures facilitate the application and control of mechanical loads. The purpose of this study was to establish a culturing method for rabbit IVD motion segments to observe the effect of static load on the whole disc organ. Segments were cultured in custom-made apparatuses under a constant, compressive load (3 kg) for 2 weeks. Tissue integrity, matrix synthesis, and matrix gene expression profile were assessed and compared with fresh one. The results showed ex vivo culturing of samples gradually destroyed the morphology. Proteoglycan contents and gene expression were decreased and downregulated obviously. However, immunohistochemical staining intensity and collagen type II gene expression were significantly enhanced and upregulated. In contrast, these trends were reversed under constant compression. These results indicated short-term static load stimulated the synthesis of type II collagen; however, constant compression led to progressive degeneration and specifically to proteoglycan. Through this study a loading and organ-culturing system for ex vivo rabbit IVD motion segments was developed, which can be used to study the effects of mechanical stimulation on the biology of IVDs and the pathomechanics of IVD degeneration.
Collapse
|
19
|
Gantenbein B, Illien-Jünger S, Chan SCW, Walser J, Haglund L, Ferguson SJ, Iatridis JC, Grad S. Organ culture bioreactors--platforms to study human intervertebral disc degeneration and regenerative therapy. Curr Stem Cell Res Ther 2016; 10:339-52. [PMID: 25764196 DOI: 10.2174/1574888x10666150312102948] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Revised: 02/25/2015] [Accepted: 03/01/2015] [Indexed: 12/31/2022]
Abstract
In recent decades the application of bioreactors has revolutionized the concept of culturing tissues and organs that require mechanical loading. In intervertebral disc (IVD) research, collaborative efforts of biomedical engineering, biology and mechatronics have led to the innovation of new loading devices that can maintain viable IVD organ explants from large animals and human cadavers in precisely defined nutritional and mechanical environments over extended culture periods. Particularly in spine and IVD research, these organ culture models offer appealing alternatives, as large bipedal animal models with naturally occurring IVD degeneration and a genetic background similar to the human condition do not exist. Latest research has demonstrated important concepts including the potential of homing of mesenchymal stem cells to nutritionally or mechanically stressed IVDs, and the regenerative potential of "smart" biomaterials for nucleus pulposus or annulus fibrosus repair. In this review, we summarize the current knowledge about cell therapy, injection of cytokines and short peptides to rescue the degenerating IVD. We further stress that most bioreactor systems simplify the real in vivo conditions providing a useful proof of concept. Limitations are that certain aspects of the immune host response and pain assessments cannot be addressed with ex vivo systems. Coccygeal animal disc models are commonly used because of their availability and similarity to human IVDs. Although in vitro loading environments are not identical to the human in vivo situation, 3D ex vivo organ culture models of large animal coccygeal and human lumbar IVDs should be seen as valid alternatives for screening and feasibility testing to augment existing small animal, large animal, and human clinical trial experiments.
Collapse
Affiliation(s)
- Benjamin Gantenbein
- Institute for Surgical Technology & Biomechanics, Medical Faculty, University, Stauffacherstrasse 78, CH-3014 Bern, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Likhitpanichkul M, Dreischarf M, Illien-Junger S, Walter BA, Nukaga T, Long RG, Sakai D, Hecht AC, Iatridis JC. Fibrin-genipin adhesive hydrogel for annulus fibrosus repair: performance evaluation with large animal organ culture, in situ biomechanics, and in vivo degradation tests. Eur Cell Mater 2014; 28:25-37; discussion 37-8. [PMID: 25036053 PMCID: PMC4409328 DOI: 10.22203/ecm.v028a03] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Annulus fibrosus (AF) defects from annular tears, herniation, and discectomy procedures are associated with painful conditions and accelerated intervertebral disc (IVD) degeneration. Currently, no effective treatments exist to repair AF damage, restore IVD biomechanics and promote tissue regeneration. An injectable fibrin-genipin adhesive hydrogel (Fib-Gen) was evaluated for its performance repairing large AF defects in a bovine caudal IVD model using ex vivo organ culture and biomechanical testing of motion segments, and for its in vivo longevity and biocompatibility in a rat model by subcutaneous implantation. Fib-Gen sealed AF defects, prevented IVD height loss, and remained well-integrated with native AF tissue following approximately 14,000 cycles of compression in 6-day organ culture experiments. Fib-Gen repair also retained high viability of native AF cells near the repair site, reduced nitric oxide released to the media, and showed evidence of AF cell migration into the gel. Biomechanically, Fib-Gen fully restored compressive stiffness to intact levels validating organ culture findings. However, only partial restoration of tensile and torsional stiffness was obtained, suggesting opportunities to enhance this formulation. Subcutaneous implantation results, when compared with the literature, suggested Fib-Gen exhibited similar biocompatibility behaviour to fibrin alone but degraded much more slowly. We conclude that injectable Fib-Gen successfully sealed large AF defects, promoted functional restoration with improved motion segment biomechanics, and served as a biocompatible adhesive biomaterial that had greatly enhanced in vivo longevity compared to fibrin. Fib-Gen offers promise for AF repairs that may prevent painful conditions and accelerated degeneration of the IVD, and warrants further material development and evaluation.
Collapse
Affiliation(s)
- M. Likhitpanichkul
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA,Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland
| | - M. Dreischarf
- Julius Wolff Institute, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - S. Illien-Junger
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA,Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland
| | - B. A. Walter
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - T. Nukaga
- Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland,Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
| | - R. G Long
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA,Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland
| | - D. Sakai
- Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland,Department of Orthopaedic Surgery, Tokai University School of Medicine, Kanagawa, Japan
| | - A. C. Hecht
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - J. C. Iatridis
- Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, New York, NY, USA,Collaborative Research Partner Annulus Fibrosus Rupture Program of AO Foundation, Davos, Switzerland,Address for correspondence: James C. Iatridis, PhD, Leni and Peter W. May Department of Orthopaedics, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, Box1188, New York, NY 10029, USA, Telephone Number: 1-212-241-1517, FAX Number: 1-212-876-3168,
| |
Collapse
|
21
|
Gawri R, Moir J, Ouellet J, Beckman L, Steffen T, Roughley P, Haglund L. Physiological loading can restore the proteoglycan content in a model of early IVD degeneration. PLoS One 2014; 9:e101233. [PMID: 24992586 PMCID: PMC4081577 DOI: 10.1371/journal.pone.0101233] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Accepted: 05/31/2014] [Indexed: 01/07/2023] Open
Abstract
A hallmark of early IVD degeneration is a decrease in proteoglycan content. Progression will eventually lead to matrix degradation, a decrease in weight bearing capacity and loss of disc height. In the final stages of IVD degradation, fissures appear in the annular ring allowing extrusion of the NP. It is crucial to understand the interplay between mechanobiology, disc composition and metabolism to be able to provide exercise recommendations to patients with early signs of disc degeneration. This study evaluates the effect of physiological loading compared to no loading on matrix homeostasis in bovine discs with induced degeneration. Bovine discs with trypsin-induced degeneration were cultured for 14 days in a bioreactor under dynamic loading with maintained metabolic activity. Chondroadherin abundance and structure was used to confirm that a functional matrix was preserved in the chosen loading environment. No change was observed in chondroadherin integrity and a non-significant increase in abundance was detected in trypsin-treated loaded discs compared to unloaded discs. The proteoglycan concentration in loaded trypsin-treated discs was significantly higher than in unloaded disc and the newly synthesised proteoglycans were of the same size range as those found in control samples. The proteoglycan showed an even distribution throughout the NP region, similar to that of control discs. Significantly more newly synthesised type II collagen was detected in trypsin-treated loaded discs compared to unloaded discs, demonstrating that physiological load not only stimulates aggrecan production, but also that of type II collagen. Taken together, this study shows that dynamic physiological load has the ability to repair the extracellular matrix depletion typical of early disc degeneration.
Collapse
Affiliation(s)
- Rahul Gawri
- Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada
| | - Janet Moir
- Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada
| | - Jean Ouellet
- McGill Scoliosis and Spine Group, Montreal, Quebec, Canada
| | - Lorne Beckman
- Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada
| | - Thomas Steffen
- Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada
| | - Peter Roughley
- Shriners Hospital for Children, McGill University, Montreal, Quebec, Canada
| | - Lisbet Haglund
- Orthopaedic Research Laboratory, McGill University, Montreal, Quebec, Canada
- * E-mail:
| |
Collapse
|
22
|
Wang AM, Cao P, Yee A, Chan D, Wu EX. Detection of extracellular matrix degradation in intervertebral disc degeneration by diffusion magnetic resonance spectroscopy. Magn Reson Med 2014; 73:1703-12. [PMID: 24817583 DOI: 10.1002/mrm.25289] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Revised: 04/16/2014] [Accepted: 04/22/2014] [Indexed: 01/07/2023]
Abstract
PURPOSE To investigate whether diffusion magnetic resonance spectroscopy (MRS) can detect the extracellular matrix (ECM) degradation during intervertebral disc degeneration (IVDD) by the increased mobility of ECM macromolecules such as proteoglycans and collagens. METHODS Fresh bovine intervertebral discs were injected with papain solution to induce ECM degradation. The apparent diffusion coefficients (ADCs), T2 values, and contents of ECM macromolecules and water resonances were measured longitudinally in the nucleus pulposus. RESULTS The macromolecule ADCs increased drastically at day 1 after papain injection, and continued increasing for 5 days. In contrast, the proteoglycan content exhibited a small and slow decrease after injection while the macromolecule T2 values, water T2, ADC, and content showed slight increase or no change. The protein gel electrophoresis analysis confirmed the gradually increased ECM fragmentation in accordance with the observed macromolecule ADC increases. CONCLUSION Diffusion MRS provides a new method to characterize the ECM degradation processes directly and sensitively. Macromolecule ADCs offer a potentially more sensitive and earlier marker for ECM degradation than the proteoglycan content and T2, and water MR properties during early IVDD. Such diffusion approach offers the possibility to directly monitor ECM integrity and degradation processes in vivo at molecular and microstructural levels in both preclinical and clinical settings.
Collapse
Affiliation(s)
- Anna M Wang
- Laboratory of Biomedical Imaging and Signal Processing, The University of Hong Kong, Pokfulam, Hong Kong SAR, China; Department of Electrical and Electronic Engineering, The University of Hong Kong, Pokfulam, Hong Kong SAR, China
| | | | | | | | | |
Collapse
|
23
|
Sun W, Zhang K, Zhao CQ, Ding W, Yuan JJ, Sun Q, Sun XJ, Xie YZ, Li H, Zhao J. Quantitative T2 mapping to characterize the process of intervertebral disc degeneration in a rabbit model. BMC Musculoskelet Disord 2013; 14:357. [PMID: 24344686 PMCID: PMC3878325 DOI: 10.1186/1471-2474-14-357] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Accepted: 12/16/2013] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND To investigate the potential of T2 mapping for characterizing the process of intervertebral disc degeneration (IDD) in a rabbit model. METHODS Thirty-five rabbits underwent an annular stab to the L4/5 discs (L5/6 discs served as internal normal controls). Degenerative changes were graded according to the modified Thompson classification and quantified in T2 respectively at pre-operation, 1, 3, 6, 12 and 24 weeks postoperatively. After MRI analysis, expression analysis of aggrecan and type II collagen gene in nucleus pulposus (NP) was performed using real time polymerase chain reaction (real-time PCR). The longitudinal changes in NP T2 and gene expressions were studied by repeated measures and ANOVA, linear regression was performed for their correlations through the process of IDD. The reliability analysis of method of measurement of NP T2 was also performed. RESULTS There was a strong inverse correlation between NP T2 and Thompson grades (r = -0.85). The decline of L4/5 NP T2 through 24 weeks was nonlinear, the most significant decrease was observed in 3 weeks postoperatively (P<0.05). The tendency was confirmed at gene expression levels. NP T2 correlated strongly with aggrecan (R² = 0.85, P<0.01) and type II collagen (R² = 0.78, P<0.01) gene expressions. The intraclass correlation coefficients for interobserver and intraobserver reliability were 0.963 and 0.977 respectively. CONCLUSIONS NP T2 correlates well with aggrecan and type II collagen gene expressions. T2 mapping could act as a sensitive, noninvasive tool for quantitatively characterizing the process of IDD in longitudinal study, help better understanding of the pathophysiology of IDD, assist us to detect the degenerative cascade, and develop a T2-based quantification scale for evaluation of IDD and efficacy of therapeutic interventions.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | - Jie Zhao
- Shanghai Key Laboratory of Orthopaedic Implant, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, 639 Zhizaoju Road, Shanghai 200011, PR China.
| |
Collapse
|
24
|
Region specific response of intervertebral disc cells to complex dynamic loading: an organ culture study using a dynamic torsion-compression bioreactor. PLoS One 2013; 8:e72489. [PMID: 24013824 PMCID: PMC3755972 DOI: 10.1371/journal.pone.0072489] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2013] [Accepted: 07/10/2013] [Indexed: 11/19/2022] Open
Abstract
The spine is routinely subjected to repetitive complex loading consisting of axial compression, torsion, flexion and extension. Mechanical loading is one of the important causes of spinal diseases, including disc herniation and disc degeneration. It is known that static and dynamic compression can lead to progressive disc degeneration, but little is known about the mechanobiology of the disc subjected to combined dynamic compression and torsion. Therefore, the purpose of this study was to compare the mechanobiology of the intervertebral disc when subjected to combined dynamic compression and axial torsion or pure dynamic compression or axial torsion using organ culture. We applied four different loading modalities [1. control: no loading (NL), 2. cyclic compression (CC), 3. cyclic torsion (CT), and 4. combined cyclic compression and torsion (CCT)] on bovine caudal disc explants using our custom made dynamic loading bioreactor for disc organ culture. Loads were applied for 8 h/day and continued for 14 days, all at a physiological magnitude and frequency. Our results provided strong evidence that complex loading induced a stronger degree of disc degeneration compared to one degree of freedom loading. In the CCT group, less than 10% nucleus pulposus (NP) cells survived the 14 days of loading, while cell viabilities were maintained above 70% in the NP of all the other three groups and in the annulus fibrosus (AF) of all the groups. Gene expression analysis revealed a strong up-regulation in matrix genes and matrix remodeling genes in the AF of the CCT group. Cell apoptotic activity and glycosaminoglycan content were also quantified but there were no statistically significant differences found. Cell morphology in the NP of the CCT was changed, as shown by histological evaluation. Our results stress the importance of complex loading on the initiation and progression of disc degeneration.
Collapse
|