1
|
Shabanov PD, Urakov AL, Urakova NA. Assessment of fetal resistance to hypoxia using the Stange test as an adjunct to Apgar scale assessment of neonatal health status. MEDICAL ACADEMIC JOURNAL 2024; 23:89-102. [DOI: 10.17816/maj568979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/26/2024]
Abstract
It has been established that the cause of biological death of fetuses in stillbirths and the cause of neonatal encephalopathies in live births is hypoxic brain cell damage in fetuses. Timely cesarean section remains the most effective way to preserve fetal life and health in the face of lethal intrauterine hypoxia. However, there is no universally recognized methodology for assessing fetal adaptation reserves to hypoxia and no methodology for selecting the type of delivery in order to perform a timely cesarean section if necessary. The Apgar score, which has been used since 1952, allows assessment of neonatal health at 1 and 5 minutes after birth, but this assessment is made without taking into account the health of the fetus before delivery. In recent years, it has been established that the outcome of fetal hypoxia is determined not only by its duration, but also by the amount of adaptive reserves available in the fetus to hypoxia. It was found that the duration of fetal immobility during apnea of a pregnant woman is an indicator of fetal resistance to hypoxia. In 2011, a method of assessing fetal resistance to intrauterine hypoxia based on the Stange test was developed in Russia. It has been found that the maximum duration of fetal immobility during maternal apnea is normally more than 30 seconds, while in the presence of fetal signs of fetoplacental insufficiency it does not reach 30 seconds, and in the presence of signs of severe fetoplacental insufficiency it does not reach 10 seconds. Therefore, it was proposed to consider good fetal resistance to hypoxia as an indication for vaginal delivery, and poor fetal resistance to hypoxia as an indication for cesarean section. A technique for assessing fetal resistance to hypoxia is described that has been developed for independent use by every pregnant woman. It is shown that it is sufficient for her to have a stopwatch and to be able to record the maximum period of fetal immobility during voluntary apnea. It is hoped that a measure of fetal resistance to hypoxia could be a meaningful complement to the Apgar score of neonatal health. It is envisioned that the use of a modified Stange test could help physicians prevent stillbirths and neonatal encephalopathies.
Collapse
|
2
|
Calcaterra V, Pagani V, Zuccotti G. Maternal and fetal health in the digital twin era. Front Pediatr 2023; 11:1251427. [PMID: 37900683 PMCID: PMC10601630 DOI: 10.3389/fped.2023.1251427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 10/03/2023] [Indexed: 10/31/2023] Open
Affiliation(s)
- Valeria Calcaterra
- Department of Internal Medicine and Therapeutics, University of Pavia, Pavia, Italy
- Pediatric Department, Buzzi Children’s Hospital, Milano, Italy
| | - Valter Pagani
- Grant & Research Department-LJA-2021, Asomi College of Sciences, Marsa, Malta
| | - Gianvincenzo Zuccotti
- Pediatric Department, Buzzi Children’s Hospital, Milano, Italy
- Department of Biomedical and Clinical Science, University of Milano, Milano, Italy
| |
Collapse
|
3
|
Stupak A, Gęca T, Kwaśniewska A, Mlak R, Piwowarczyk P, Nawrot R, Goździcka-Józefiak A, Kwaśniewski W. Comparative Analysis of the Placental Microbiome in Pregnancies with Late Fetal Growth Restriction versus Physiological Pregnancies. Int J Mol Sci 2023; 24:ijms24086922. [PMID: 37108086 PMCID: PMC10139004 DOI: 10.3390/ijms24086922] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/03/2023] [Accepted: 04/06/2023] [Indexed: 04/29/2023] Open
Abstract
A comparative analysis of the placental microbiome in pregnancies with late fetal growth restriction (FGR) was performed with normal pregnancies to assess the impact of bacteria on placental development and function. The presence of microorganisms in the placenta, amniotic fluid, fetal membranes and umbilical cord blood throughout pregnancy disproves the theory of the "sterile uterus". FGR occurs when the fetus is unable to follow a biophysically determined growth path. Bacterial infections have been linked to maternal overproduction of pro-inflammatory cytokines, as well as various short- and long-term problems. Proteomics and bioinformatics studies of placental biomass allowed the development of new diagnostic options. In this study, the microbiome of normal and FGR placentas was analyzed by LC-ESI-MS/MS mass spectrometry, and the bacteria present in both placentas were identified by analysis of a set of bacterial proteins. Thirty-six pregnant Caucasian women participated in the study, including 18 women with normal pregnancy and eutrophic fetuses (EFW > 10th percentile) and 18 women with late FGR diagnosed after 32 weeks of gestation. Based on the analysis of the proteinogram, 166 bacterial proteins were detected in the material taken from the placentas in the study group. Of these, 21 proteins had an exponentially modified protein abundance index (emPAI) value of 0 and were not included in further analysis. Of the remaining 145 proteins, 52 were also present in the material from the control group. The remaining 93 proteins were present only in the material collected from the study group. Based on the proteinogram analysis, 732 bacterial proteins were detected in the material taken from the control group. Of these, 104 proteins had an emPAI value of 0 and were not included in further analysis. Of the remaining 628 proteins, 52 were also present in the material from the study group. The remaining 576 proteins were present only in the material taken from the control group. In both groups, we considered the result of ns prot ≥ 60 as the cut-off value for the agreement of the detected protein with its theoretical counterpart. Our study found significantly higher emPAI values of proteins representative of the following bacteria: Actinopolyspora erythraea, Listeria costaricensis, E. coli, Methylobacterium, Acidobacteria bacterium, Bacteroidetes bacterium, Paenisporsarcina sp., Thiodiazotropha endol oripes and Clostridiales bacterium. On the other hand, in the control group statistically more frequently, based on proteomic data, the following were found: Flavobacterial bacterium, Aureimonas sp. and Bacillus cereus. Our study showed that placental dysbiosis may be an important factor in the etiology of FGR. The presence of numerous bacterial proteins present in the control material may indicate their protective role, while the presence of bacterial proteins detected only in the material taken from the placentas of the study group may indicate their potentially pathogenic nature. This phenomenon is probably important in the development of the immune system in early life, and the placental microbiota and its metabolites may have great potential in the screening, prevention, diagnosis and treatment of FGR.
Collapse
Affiliation(s)
- Aleksandra Stupak
- Chair and Department of Obstetrics and Pathology of Pregnancy, Medical University of Lublin, 20-059 Lublin, Poland
| | - Tomasz Gęca
- Chair and Department of Obstetrics and Pathology of Pregnancy, Medical University of Lublin, 20-059 Lublin, Poland
| | - Anna Kwaśniewska
- Chair and Department of Obstetrics and Pathology of Pregnancy, Medical University of Lublin, 20-059 Lublin, Poland
| | - Radosław Mlak
- Body Composition Research Laboratory, Department of Preclinical Science, Medical University of Lublin, 20-059 Lublin, Poland
| | - Paweł Piwowarczyk
- 2nd Department of Anesthesiology and Intensive Care Unit, Medical University of Lublin, 20-059 Lublin, Poland
| | - Robert Nawrot
- Department of Molecular Virology, Institute of Experimental Biology, Adam Mickiewicz University in Poznan, 61-712 Poznań, Poland
| | - Anna Goździcka-Józefiak
- Department of Molecular Virology, Institute of Experimental Biology, Adam Mickiewicz University in Poznan, 61-712 Poznań, Poland
| | - Wojciech Kwaśniewski
- Department of Gynecologic Oncology and Gynecology, Medical University of Lublin, 20-059 Lublin, Poland
| |
Collapse
|
4
|
Seval MM, Varlı B. Current developments in artificial intelligence from obstetrics and gynecology to urogynecology. Front Med (Lausanne) 2023; 10:1098205. [PMID: 36910480 PMCID: PMC9995368 DOI: 10.3389/fmed.2023.1098205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 02/09/2023] [Indexed: 02/25/2023] Open
Abstract
In today's medical practice clinicians need to struggle with a huge amount of data to improve the outcomes of the patients. Sometimes one clinician needs to deal with thousands of ultrasound images or hundred papers of laboratory results. To overcome this shortage, computers get in help of human beings and they are educated under the term "artificial intelligence." We were using artificial intelligence in our daily lives (i.e., Google, Netflix, etc.), but applications in medicine are relatively new. In obstetrics and gynecology, artificial intelligence models mostly use ultrasound images for diagnostic purposes but nowadays researchers started to use other medical recordings like non-stress tests or urodynamics study results to develop artificial intelligence applications. Urogynecology is a developing subspecialty of obstetrics and gynecology, and articles about artificial intelligence in urogynecology are limited but in this review, we aimed to increase clinicians' knowledge about this new approach.
Collapse
Affiliation(s)
- Mehmet Murat Seval
- Department of Obstetrics and Gynecology, Ankara University School of Medicine, Ankara, Türkiye
| | - Bulut Varlı
- Department of Obstetrics and Gynecology, Ankara University School of Medicine, Ankara, Türkiye
| |
Collapse
|
5
|
Interrelation between miRNAs Expression Associated with Redox State Fluctuations, Immune and Inflammatory Response Activation, and Neonatal Outcomes in Complicated Pregnancy, Accompanied by Placental Insufficiency. Antioxidants (Basel) 2022; 12:antiox12010006. [PMID: 36670868 PMCID: PMC9854567 DOI: 10.3390/antiox12010006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 12/15/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022] Open
Abstract
Redox disbalance in placental cells leads to the hyperproduction of reactive oxygen species (ROS), it mediates the dysregulation of the maternal immune tolerance to a semi-allogenic fetus, inducing pro-inflammatory reactions, and it plays a central role in perinatal complications and neonatal disease programming. Microvesicles, which provide transplacental communication between a mother and fetus, contain microRNAs (miRNAs) that are sensitive to oxidative stress (OS) mediators and can control the balance of ROS production and utilization in target cells. In the context of this paradigm, we evaluated the markers of redox balance—MDA and 4-HNE for OS and GPx, and SOD, CAT, and GSH for the antioxidant system in the cord blood plasma of newborns diagnosed with fetal growth restriction (FGR)—by using polarography, spectrophotometry, and Western blotting. The expression of miRNAs associated with OS, immune and inflammatory responses in the blood plasma of newborns with intrauterine pneumonia (IP), neonatal sepsis (NS) and respiratory distress syndrome (RDS) was evaluated by a quantitative RT-PCR. Significant differences in the MDA level and reduced GPx and CAT activity were co-found for early-onset FGR (i.e., <34 gestational age). Significant correlations were found with a low birth weight by Apgar scores with reduced levels of antioxidant enzymes. Indeed, the level of OS markers increased in early-onset FGR in newborns with an extremely low body weight and high echogenicity of the periventricular zones, and reduced in late-onset FGR in newborns with IP, hyperbilirubinemia, intraventricular hemorrhage (IVH) and cerebral cysts. A prognostic model (AUC = 1; cutoff—0.5) was developed to assess the risk of IVH in newborns diagnosed with FGR based on the assessment of the OS markers (i.e., MDA + 4 HNE + CAT + GSH). A significant increase in the miR-127-3p expression was found in the plasma of newborns with NS (<32 GA; p ≤ 0.03 and >32 GA; p ≤ 0.009), IP (>32 GA; p ≤ 0.0001), and RDS (>32 GA; p ≤ 0.03). At the same time, the expression of miR-25-3p (p ≤ 0.03) was increased only in newborns with NS (>32 GA; p ≤ 0.03). The risk of developing IVH for premature newborns with IP (AUC = 0.8; cutoff—0.6) and NS (AUC = 0.68; cutoff—0.49) was assessed based on the miR-25-3p and miR-127-3p expression. Several key transcription factors were identified as the targets of studied miRNA since they are involved in the regulation of OS (NRF2), signaling and activation of the immune response (PRDM1, CCL26) and, also, inflammatory responses (NFKB1). The study of these miRNAs showed that they are involved in the modulation of processes leading to perinatal complications. Moreover, miR-127-3p is related to pro-inflammatory reactions and the formation of the macrophage phenotype in newborns with IP, NS, and RDS, while miR-25-3p is associated with an inhibition of macrophage migration and activation of antioxidant enzymes, which may prevent the development of oxidative damage in newborns with NS.
Collapse
|
6
|
Dhombres F, Bonnard J, Bailly K, Maurice P, Papageorghiou A, Jouannic JM. Contributions of artificial intelligence reported in Obstetrics and Gynecology journals: a systematic review. J Med Internet Res 2022; 24:e35465. [PMID: 35297766 PMCID: PMC9069308 DOI: 10.2196/35465] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 02/11/2022] [Accepted: 03/15/2022] [Indexed: 11/13/2022] Open
Abstract
Background The applications of artificial intelligence (AI) processes have grown significantly in all medical disciplines during the last decades. Two main types of AI have been applied in medicine: symbolic AI (eg, knowledge base and ontologies) and nonsymbolic AI (eg, machine learning and artificial neural networks). Consequently, AI has also been applied across most obstetrics and gynecology (OB/GYN) domains, including general obstetrics, gynecology surgery, fetal ultrasound, and assisted reproductive medicine, among others. Objective The aim of this study was to provide a systematic review to establish the actual contributions of AI reported in OB/GYN discipline journals. Methods The PubMed database was searched for citations indexed with “artificial intelligence” and at least one of the following medical subject heading (MeSH) terms between January 1, 2000, and April 30, 2020: “obstetrics”; “gynecology”; “reproductive techniques, assisted”; or “pregnancy.” All publications in OB/GYN core disciplines journals were considered. The selection of journals was based on disciplines defined in Web of Science. The publications were excluded if no AI process was used in the study. Review, editorial, and commentary articles were also excluded. The study analysis comprised (1) classification of publications into OB/GYN domains, (2) description of AI methods, (3) description of AI algorithms, (4) description of data sets, (5) description of AI contributions, and (6) description of the validation of the AI process. Results The PubMed search retrieved 579 citations and 66 publications met the selection criteria. All OB/GYN subdomains were covered: obstetrics (41%, 27/66), gynecology (3%, 2/66), assisted reproductive medicine (33%, 22/66), early pregnancy (2%, 1/66), and fetal medicine (21%, 14/66). Both machine learning methods (39/66) and knowledge base methods (25/66) were represented. Machine learning used imaging, numerical, and clinical data sets. Knowledge base methods used mostly omics data sets. The actual contributions of AI were method/algorithm development (53%, 35/66), hypothesis generation (42%, 28/66), or software development (3%, 2/66). Validation was performed on one data set (86%, 57/66) and no external validation was reported. We observed a general rising trend in publications related to AI in OB/GYN over the last two decades. Most of these publications (82%, 54/66) remain out of the scope of the usual OB/GYN journals. Conclusions In OB/GYN discipline journals, mostly preliminary work (eg, proof-of-concept algorithm or method) in AI applied to this discipline is reported and clinical validation remains an unmet prerequisite. Improvement driven by new AI research guidelines is expected. However, these guidelines are covering only a part of AI approaches (nonsymbolic) reported in this review; hence, updates need to be considered.
Collapse
Affiliation(s)
- Ferdinand Dhombres
- Sorbonne University, Armand Trousseau University hospital, Fetal Medicine department, APHP, Armand Trousseau University hospital, Fetal Medicine department, APHP26 AV du Dr Arnold Netter, Paris, FR.,INSERM, Laboratory in Medical Informatics and Knowledge Engineering in e-Health (LIMICS), Paris, FR
| | - Jules Bonnard
- Sorbonne University, Institute for Intelligent Systems and Robotics (ISIR), Paris, FR
| | - Kévin Bailly
- Sorbonne University, Institute for Intelligent Systems and Robotics (ISIR), Paris, FR
| | - Paul Maurice
- Sorbonne University, Armand Trousseau University hospital, Fetal Medicine department, APHP, Paris, FR
| | - Aris Papageorghiou
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, Oxford, GB
| | - Jean-Marie Jouannic
- Sorbonne University, Armand Trousseau University hospital, Fetal Medicine department, APHP, Paris, FR.,INSERM, Laboratory in Medical Informatics and Knowledge Engineering in e-Health (LIMICS), Paris, FR
| |
Collapse
|
7
|
Gusar V, Ganichkina M, Chagovets V, Kan N, Sukhikh G. MiRNAs Regulating Oxidative Stress: A Correlation with Doppler Sonography of Uteroplacental Complex and Clinical State Assessments of Newborns in Fetal Growth Restriction. J Clin Med 2020; 9:jcm9103227. [PMID: 33050114 PMCID: PMC7650709 DOI: 10.3390/jcm9103227] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 09/29/2020] [Accepted: 10/06/2020] [Indexed: 02/08/2023] Open
Abstract
Overproduction of reactive oxygen species (ROS) and, as a result, uncontrolled oxidative stress (OS) can play a central role in disorders of fetal hemodynamics and subsequent development of adverse perinatal outcomes in newborns with fetal growth restriction (FGR). Given the epigenetic nature of such disorders, the aim of our study was to evaluate the expression of miRNAs associated with OS and endothelial dysfunction (miR-27a-3p, miR-30b-5p, miR-125b-5p, miR-221-3p, miR-451a and miR-574-3p) in umbilical cord blood using real-time quantitative RT-PCR. ΜiRNA expression was evaluated in patients with FGR delivery before (n = 9 pregnant) and after 34 weeks of gestation (n = 13 pregnant), and the control groups corresponding to the main groups by gestational age (13 pregnant women in each group, respectively). A significant increase in miR-451a expression was detected in late-onset FGR and correlations with fetoplacental and cerebral circulation were established (increase of resistance in the umbilical artery (pulsatility index, PI UA (umbilical artery): r = −0.59, p = 0.001) and a decrease in cerebral blood flow (CPR: r = 0.48, p = 0.009)). The change in miR-125b-5p expression in the placenta is associated with reduced Doppler of cerebral hemodynamics (CPR: r = 0.73, p = 0.003; PI MCA (middle cerebral artery): r = 0.79, p = 0.0007), and newborn weight (r = 0.56, p = 0.04) in early-onset FGR. In addition, significant changes in miR-125b-5p and miR-451a expression in umbilical cord blood plasma were found in newborns with neonatal respiratory distress syndrome (NRDS) (in early-onset FGR) and very low birth weight (VLBW) (in late-onset FGR). A number of key signaling pathways have been identified in which the regulation of the studied miRNAs is involved, including angiogenesis, neurotrophin signaling pathway and oxidative stress response. In general, our study showed that changes of the redox homeostasis in the mother-placenta-fetus system in FGR and subsequent perinatal outcomes may be due to differential expression of oxidative stress-associated miRNAs.
Collapse
Affiliation(s)
- Vladislava Gusar
- Laboratory of Applied Transcriptomics, Federal State Budget Institution “National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov of the Ministry of Healthcare of the Russian Federation”, Oparin str. 4, 117997 Moscow, Russia
- Correspondence: or ; Tel.: +7-916-283-72-10
| | - Mariya Ganichkina
- Obstetric Physiological Department, Federal State Budget Institution “National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov of the Ministry of Healthcare of the Russian Federation”, Oparin str. 4, 117997 Moscow, Russia;
| | - Vitaliy Chagovets
- Laboratory of Proteomics and Metabolomics of Human Reproduction, Federal State Budget Institution “National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov of the Ministry of Healthcare of the Russian Federation”, Oparin str. 4, 117997 Moscow, Russia;
| | - Nataliya Kan
- Department for Obstetrics and Gynecology, Professional Education Department, Federal State Budget Institution “National Medical Research Center for Obstetrics, Gynecology and/Perinatology named after Academician V.I. Kulakov of the Ministry of Healthcare of the Russian Federation”, Oparin str. 4, 117997 Moscow, Russia;
| | - Gennadiy Sukhikh
- Federal State Budget Institution “National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov of the Ministry of Healthcare of the Russian Federation”, Oparin str. 4, 117997 Moscow, Russia;
- Department of Obstetrics, Gynecology, Perinatology and Reproductive Medicine, Institute of Professional Education, Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University), Bolshaya Pirogovskaya str., 2, 119991 Moscow, Russia
| |
Collapse
|
8
|
Drukker L, Noble JA, Papageorghiou AT. Introduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 56:498-505. [PMID: 32530098 PMCID: PMC7702141 DOI: 10.1002/uog.22122] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 05/10/2020] [Accepted: 06/01/2020] [Indexed: 05/05/2023]
Abstract
Artificial intelligence (AI) uses data and algorithms to aim to draw conclusions that are as good as, or even better than, those drawn by humans. AI is already part of our daily life; it is behind face recognition technology, speech recognition in virtual assistants (such as Amazon Alexa, Apple's Siri, Google Assistant and Microsoft Cortana) and self-driving cars. AI software has been able to beat world champions in chess, Go and recently even Poker. Relevant to our community, it is a prominent source of innovation in healthcare, already helping to develop new drugs, support clinical decisions and provide quality assurance in radiology. The list of medical image-analysis AI applications with USA Food and Drug Administration or European Union (soon to fall under European Union Medical Device Regulation) approval is growing rapidly and covers diverse clinical needs, such as detection of arrhythmia using a smartwatch or automatic triage of critical imaging studies to the top of the radiologist's worklist. Deep learning, a leading tool of AI, performs particularly well in image pattern recognition and, therefore, can be of great benefit to doctors who rely heavily on images, such as sonologists, radiographers and pathologists. Although obstetric and gynecological ultrasound are two of the most commonly performed imaging studies, AI has had little impact on this field so far. Nevertheless, there is huge potential for AI to assist in repetitive ultrasound tasks, such as automatically identifying good-quality acquisitions and providing instant quality assurance. For this potential to thrive, interdisciplinary communication between AI developers and ultrasound professionals is necessary. In this article, we explore the fundamentals of medical imaging AI, from theory to applicability, and introduce some key terms to medical professionals in the field of ultrasound. We believe that wider knowledge of AI will help accelerate its integration into healthcare. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
Affiliation(s)
- L. Drukker
- Nuffield Department of Women's & Reproductive HealthUniversity of Oxford, John Radcliffe HospitalOxfordUK
| | - J. A. Noble
- Institute of Biomedical EngineeringUniversity of OxfordOxfordUK
| | - A. T. Papageorghiou
- Nuffield Department of Women's & Reproductive HealthUniversity of Oxford, John Radcliffe HospitalOxfordUK
| |
Collapse
|
9
|
Grüttner B, Ratiu J, Ratiu D, Gottschalk I, Morgenstern B, Abel JS, Eichler C, Pahmeyer C, Ludwig S, Mallmann P, Thangarajah F. Correlation of Cerebroplacental Ratio (CPR) With Adverse Perinatal Outcome in Singleton Pregnancies. In Vivo 2020; 33:1703-1706. [PMID: 31471427 DOI: 10.21873/invivo.11659] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 07/01/2019] [Accepted: 07/10/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND/AIM For many years clinical research has been concerned with doppler sonography as a non-invasive tool for intrauterine fetal status assessment. A new focus is now placed on the measurement of cerebroplacental index (CPR) as a predictor of fetal outcome. Our aim was to investigate the relationship between the cerebroplacental ratio (CPR), the delivery mode and the fetal outcome in singleton pregnancies. PATIENTS AND METHODS A retrospective cohort study of pregnancies in which doppler sonography of middle cerebral artery (MCA) and umbilical artery (UA) was conducted up to 9 weeks before delivery took place. Patients with pathological (CPR≤1.0) and normal CPR (>1.0) were compared by umbilical cord pH, APGAR scores, birth weight, delivery week and delivery mode. RESULTS A total of 2,270 singleton pregnancies were included. The APGAR score for 1, 5 and 10 minutes and the gestational age at delivery were significantly lower in the group of patients with pathological CPR (p<0.001). Overall, 50% of the cohort had a cesarean section, the difference between the groups was statistically significant (p<0.001), with a higher amount of cesareans in the group of patients with pathological CPR. The multiple regression analysis showed a significantly improved pH of delivery when cesarean section (p<0.001), female sex of fetus (p=0.013) and higher CPR (p=0.035) were present. CONCLUSION The measurement of CPR is an important, non-invasive predictive parameter and leads to the identification of a risk collective even in the non-selected patient population and thus probably to a reduction of perinatal morbidity.
Collapse
Affiliation(s)
- Berthold Grüttner
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Jessika Ratiu
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Dominik Ratiu
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Ingo Gottschalk
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Bernd Morgenstern
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Judith Sarah Abel
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Christian Eichler
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Caroline Pahmeyer
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Sebastian Ludwig
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Peter Mallmann
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| | - Fabinshy Thangarajah
- Department of Obstetrics and Gynecology, University Hospital Cologne and Medical Faculty, Cologne, Germany
| |
Collapse
|
10
|
Guo LN, Chai YQ, Guo S, Zhang ZK. Prediction of neonatal acidosis using the cerebroplacental ratio at different gestational weeks: A case-control study. Medicine (Baltimore) 2019; 98:e16458. [PMID: 31335703 PMCID: PMC6709098 DOI: 10.1097/md.0000000000016458] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
We evaluated the clinical value of the cerebroplacental ratio (CPR) in predicting neonatal acidosis according to the gestational weeks in late pregnancy.From July 2016 to June 2017, 1018 neonates without acidosis and 218 neonates with acidosis (confirmed postpartum) underwent a prenatal examination and hospital delivery at 28 to 41 weeks in our hospital. The CPR was calculated as the ratio of the prenatal middle cerebral artery-pulsation index (MCA-PI) to the umbilical artery-pulsation index (UA-PI).In neonates without acidosis, the fetal UA-PI decreased with increased gestational age during late pregnancy. Similarly, the MCA-PI decreased with increased gestational age, and decreased significantly during the full pregnancy term. Additionally, the CPR peaked in the middle of the late pregnancy period and then decreased. In contrast, in neonates with acidosis, the prenatal UA-PI increased significantly, MCA-PI declined significantly, and CPR declined significantly in relation to normal values (P < .05). For the prediction of neonatal acidosis, the UA-PI was suitable after 32 weeks and the MCA-PI was suitable before 37 weeks. The cutoff values of the CPR for the prediction of neonatal acidosis at 28 to 31 weeks, 32 to 36 weeks, and 37 to 41 weeks were 1.29, 1.36, and 1.22, respectively. Unlike the UA-PI and MCA-PI, the CPR was suitable as an independent predictor of neonatal acidosis at all late pregnancy weeks. In neonates with acidosis, the z score of the UA-PI increased significantly, whereas the z scores of the MCA-PI and CPR decreased significantly, in relation to normal values (P < .05).The CPR can be used to evaluate the adverse status of fetuses during late pregnancy, providing an early prediction of neonatal acidosis.
Collapse
MESH Headings
- Acidosis/diagnosis
- Case-Control Studies
- Early Diagnosis
- Female
- Fetus/metabolism
- Fetus/physiopathology
- Gestational Age
- Humans
- Infant, Newborn
- Infant, Newborn, Diseases/diagnosis
- Infant, Newborn, Diseases/metabolism
- Infant, Newborn, Diseases/physiopathology
- Middle Cerebral Artery/diagnostic imaging
- Predictive Value of Tests
- Pregnancy
- Prenatal Diagnosis/methods
- Prognosis
- Pulsatile Flow
- Ultrasonography, Doppler, Color/methods
- Ultrasonography, Prenatal/methods
- Umbilical Arteries/diagnostic imaging
Collapse
|
11
|
Conde-Agudelo A, Villar J, Kennedy SH, Papageorghiou AT. Predictive accuracy of cerebroplacental ratio for adverse perinatal and neurodevelopmental outcomes in suspected fetal growth restriction: systematic review and meta-analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 52:430-441. [PMID: 29920817 DOI: 10.1002/uog.19117] [Citation(s) in RCA: 101] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 05/21/2018] [Accepted: 05/23/2018] [Indexed: 06/08/2023]
Abstract
OBJECTIVE The cerebroplacental ratio (CPR) has been proposed for the routine surveillance of pregnancies with suspected fetal growth restriction (FGR), but the predictive performance of this test is unclear. The aim of this study was to determine the accuracy of CPR for predicting adverse perinatal and neurodevelopmental outcomes in suspected FGR. METHODS PubMed, EMBASE, CINAHL and Lilacs were searched from inception to 31 July 2017 for cohort or cross-sectional studies reporting on the accuracy of CPR for predicting adverse perinatal and/or neurodevelopmental outcomes in singleton pregnancies with FGR suspected antenatally based on sonographic parameters. Summary receiver-operating characteristics (ROC) curves, pooled sensitivities and specificities, and summary likelihood ratios (LRs) were generated. RESULTS Twenty-two studies (including 4301 women) met the inclusion criteria. Summary ROC curves showed that the best predictive accuracy of CPR was for perinatal death and the worst was for neonatal acidosis, with areas under the summary ROC curves of 0.83 and 0.57, respectively. The predictive accuracy of CPR was moderate to high for perinatal death (pooled sensitivity and specificity of 93% and 76%, respectively, and summary positive and negative LRs of 3.9 and 0.09, respectively) and low for composite of adverse perinatal outcomes, Cesarean section for non-reassuring fetal status, 5-min Apgar score < 7, admission to the neonatal intensive care unit, neonatal acidosis and neonatal morbidity, with summary positive and negative LRs ranging from 1.1 to 2.5 and 0.3 to 0.9, respectively. An abnormal CPR result had moderate accuracy for predicting small-for-gestational age at birth (summary positive LR of 7.4). CPR had a higher predictive accuracy in pregnancies with suspected early-onset FGR. No study provided data for assessing the predictive accuracy of CPR for adverse neurodevelopmental outcome. CONCLUSION CPR appears to be useful in predicting perinatal death in pregnancies with suspected FGR. Nevertheless, before incorporating CPR into the routine clinical management of suspected FGR, randomized controlled trials should assess whether the use of CPR reduces perinatal death or other adverse perinatal outcomes. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- A Conde-Agudelo
- Perinatology Research Branch, Eunice Kennedy Shriver National Institute of Child Health and Human Development/National Institutes of Health/Department of Health and Human Services, Bethesda, MD, and Detroit, MI, USA
| | - J Villar
- Nuffield Department of Obstetrics & Gynaecology, University of Oxford, Women's Centre, John Radcliffe Hospital, Oxford, UK
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, Oxford, UK
| | - S H Kennedy
- Nuffield Department of Obstetrics & Gynaecology, University of Oxford, Women's Centre, John Radcliffe Hospital, Oxford, UK
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, Oxford, UK
| | - A T Papageorghiou
- Nuffield Department of Obstetrics & Gynaecology, University of Oxford, Women's Centre, John Radcliffe Hospital, Oxford, UK
- Oxford Maternal & Perinatal Health Institute, Green Templeton College, Oxford, UK
| |
Collapse
|
12
|
Valensise H, Tiralongo GM, Pisani I, Farsetti D, Lo Presti D, Gagliardi G, Basile MR, Novelli GP, Vasapollo B. Maternal hemodynamics early in labor: a possible link with obstetric risk? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2018; 51:509-513. [PMID: 28236342 DOI: 10.1002/uog.17447] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 02/08/2017] [Accepted: 02/15/2017] [Indexed: 06/06/2023]
Abstract
OBJECTIVE To determine if hemodynamic assessment in 'low-risk' pregnant women at term with an appropriate-for-gestational age (AGA) fetus can improve the identification of patients who will suffer maternal or fetal/neonatal complications during labor. METHODS This was a prospective observational study of 77 women with low-risk term pregnancy and AGA fetus, in the early stages of labor. Hemodynamic indices were obtained using the UltraSonic Cardiac Output Monitor (USCOM® ) system. Patients were followed until the end of labor to identify fetal/neonatal and maternal outcomes, and those which developed complications of labor were compared with those delivering without complications. RESULTS Eleven (14.3%) patients had a complication during labor: in seven there was fetal distress and in four there were maternal complications (postpartum hemorrhage and/or uterine atony). Patients who developed complications during labor had lower cardiac output (5.6 ± 1.0 vs 6.7 ± 1.3 L/min, P = 0.01) and cardiac index (3.1 ± 0.6 vs 3.5 ± 0.7 L/min/m2 , P = 0.04), and higher total vascular resistance (1195.3 ± 205.3 vs 1017.8 ± 225.6 dynes × s/cm5 , P = 0.017) early in labor, compared with those who did not develop complications. Receiver-operating characteristics curve analysis to determine cut-offs showed cardiac output ≤ 5.8 L/min (sensitivity, 81.8%; specificity, 69.7%), cardiac index ≤ 2.9 L/min/m2 (sensitivity, 63.6%; specificity, 76.9%) and total vascular resistance > 1069 dynes × s/cm5 (sensitivity, 81.8%; specificity, 63.6%) to best predict maternal or fetal/neonatal complications. CONCLUSIONS The study of maternal cardiovascular adaptation at the end of pregnancy could help to identify low-risk patients who may develop complications during labor. In particular, low cardiac output and high total vascular resistance are apparently associated with higher risk of fetal distress or maternal complications. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- H Valensise
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - G M Tiralongo
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - I Pisani
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - D Farsetti
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - D Lo Presti
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - G Gagliardi
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - M R Basile
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| | - G P Novelli
- Department of Cardiology, San Sebastiano Martire Hospital, Frascati, Rome, Italy
| | - B Vasapollo
- Department of Biomedicine - Obstetrics and Gynecology Policlinico Casilino, Tor Vergata University, Rome, Italy
| |
Collapse
|
13
|
Review: Systematic review of the utility of the fetal cerebroplacental ratio measured at term for the prediction of adverse perinatal outcome. Placenta 2017; 54:68-75. [PMID: 28216258 DOI: 10.1016/j.placenta.2017.02.006] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Revised: 02/02/2017] [Accepted: 02/07/2017] [Indexed: 11/20/2022]
Abstract
AIM This systematic review evaluates the utility of the fetal cerebroplacental ratio (CPR) when assessed at term (from 37 + 0 weeks gestation) as a predictor of adverse obstetric and perinatal outcomes. DATA SOURCES AND SEARCH STRATEGY An electronic search of Pubmed and Embase using variations of 'cerebroplacental ratio' and 'cerebroumbilical ratio' was conducted by two independent reviewers. Full text studies written in English that reported on low CPR and its correlation with relevant obstetric and perinatal outcomes were included. RESULTS Twenty one studies satisfied inclusion with 13 prospective and eight retrospective analyses. Fetal CPR was predictive of caesarean section for intrapartum fetal compromise, small for gestational age and fetal growth restriction and neonatal intensive care unit admission. Low CPR was also significantly associated with abnormal fetal heart rate pattern, meconium stained liquor, low Apgar score, acidosis at birth and composite adverse perinatal outcome scores. The CPR when taken at term had comparable if not better predictive value than that when taken at preterm. Most studies included small for gestational age fetuses and postdate pregnancies. Subtle variation existed in the threshold for low CPR. CONCLUSION The CPR at term has a strong association with adverse obstetric and perinatal outcomes. This review suggests the predictive utility of CPR at term is promising however there is insufficient evidence to demonstrate its value as a stand-alone test. Inclusion of CPR as a component of clinical care may help better identify fetuses at risk of adverse outcome, and this should be tested with randomised control trials.
Collapse
|
14
|
Schneider ME, Lombardo P. Brain Surface Heating After Exposure to Ultrasound: An Analysis Using Thermography. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1138-1144. [PMID: 26924696 DOI: 10.1016/j.ultrasmedbio.2016.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 11/05/2015] [Accepted: 01/05/2016] [Indexed: 06/05/2023]
Abstract
Ultrasound is the imaging modality of choice to monitor brain pathologies in neonates after complicated deliveries. Animal studies have indicated that ultrasound may cause heating of brain tissues. To date, no study has explored brain surface heating by ultrasound during clinically relevant exposure. Hence, we investigated heating effects of B-mode and pulsed Doppler (PD) mode on ex vivo lamb brains using thermography. Five brains were scanned for 5 min in B-mode or for 3 min, 1 min, 30 s or 15 s in PD mode. Brain surface temperature was measured pre- and post-exposure using thermography. The highest mean temperature increase was recorded by B-mode (3.82 ± 0.43°C). All five PD exposure protocols were associated with surface temperature increases of 2.1-2.7°C. These outcomes highlight for the first time that B-mode ultrasound can contribute to brain surface heating during a routine cranial scan. Scan duration should be minimised whenever possible.
Collapse
Affiliation(s)
- Michal E Schneider
- Department of Medical Imaging and Radiation Sciences, School of Biomedical Science, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Victoria, Australia.
| | - Paul Lombardo
- Department of Medical Imaging and Radiation Sciences, School of Biomedical Science, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Victoria, Australia
| |
Collapse
|
15
|
Starčević M, Predojević M, Butorac D, Tumbri J, Konjevoda P, Kadić AS. Early functional and morphological brain disturbances in late-onset intrauterine growth restriction. Early Hum Dev 2016; 93:33-8. [PMID: 26759989 DOI: 10.1016/j.earlhumdev.2015.12.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 11/26/2015] [Accepted: 12/09/2015] [Indexed: 10/22/2022]
Abstract
AIMS To determine whether the brain disturbances develop in late-onset intrauterine growth restriction (IUGR) before blood flow redistribution towards the fetal brain (detected by Doppler measurements in the middle cerebral artery and umbilical artery). Further, to evaluate predictive values of Doppler arterial indices and umbilical cord blood gases and pH for early functional and/or morphological brain disturbances in late-onset IUGR. STUDY DESIGN This cohort study included 60 singleton term pregnancies with placental insufficiency caused late-onset IUGR (IUGR occurring after 34 gestational weeks). Umbilical artery resistance index (URI), middle cerebral artery resistance index (CRI), and cerebroumbilical (C/U) ratio (CRI/URI) were monitored once weekly. Umbilical blood cord samples (arterial and venous) were collected for the analysis of pO2, pCO2 and pH. Morphological neurological outcome was evaluated by cranial ultrasound (cUS), whereas functional neurological outcome by Amiel-Tison Neurological Assessment at Term (ATNAT). RESULTS 50 fetuses had C/U ratio>1, and 10 had C/U ratio≤1; among these 10 fetuses, 9 had abnormal neonatal cUS findings and all 10 had non-optimal ATNAT. However, the total number of abnormal neurological findings was much higher. 32 neonates had abnormal cUS (53.37%), and 42 (70.00%) had non-optimal ATNAT. Furthermore, Doppler indices had higher predictive validity for early brain disturbances than umbilical cord blood gases and pH. C/U ratio had the highest predictive validity with threshold for adverse neurological outcome at value 1.13 (ROC analysis), i.e., 1.18 (party machine learning algorithm). CONCLUSION Adverse neurological outcome at average values of C/U ratios>1 confirmed that early functional and/or structural brain disturbances in late-onset IUGR develop even before activation of fetal cardiovascular compensatory mechanisms, i.e., before Doppler signs of blood flow redistribution between the fetal brain and the placenta.
Collapse
Affiliation(s)
- Mirta Starčević
- Division of Neonatology, Department of Pediatrics, Clinical Hospital Center "Sestre milosrdnice", Medical School, University of Zagreb, Vinogradska cesta 29, 10000 Zagreb, Croatia
| | - Maja Predojević
- Department of Obstetrics and Gynecology, Clinical Hospital "Sveti Duh", Medical School, University of Zagreb, Sveti Duh 64, 10000 Zagreb, Croatia.
| | - Dražan Butorac
- Department of Obstetrics and Gynecology, Clinical Hospital Center "Sestre milosrdnice", Medical School, University of Zagreb, Vinogradska cesta 29, 10000 Zagreb, Croatia
| | - Jasna Tumbri
- Division of Neonatology, Department of Pediatrics, Clinical Hospital Center "Sestre milosrdnice", Medical School, University of Zagreb, Vinogradska cesta 29, 10000 Zagreb, Croatia
| | - Paško Konjevoda
- Nuclear Magnetic Resonance Center, Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb, Croatia
| | - Aida Salihagić Kadić
- Department of Physiology, Medical School, University of Zagreb, Šalata 3, 10000 Zagreb, Croatia
| |
Collapse
|
16
|
DeVore GR. The importance of the cerebroplacental ratio in the evaluation of fetal well-being in SGA and AGA fetuses. Am J Obstet Gynecol 2015; 213:5-15. [PMID: 26113227 DOI: 10.1016/j.ajog.2015.05.024] [Citation(s) in RCA: 189] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2015] [Revised: 04/29/2015] [Accepted: 05/13/2015] [Indexed: 10/23/2022]
Abstract
The cerebroplacental ratio (CPR) is emerging as an important predictor of adverse pregnancy outcome, and this has implications for the assessment of fetal well-being in fetuses diagnosed as small for gestational age (SGA) and those appropriate for gestational age close to term. Interest in this assessment tool has been rekindled because of recent reports associating an abnormal ratio with adverse perinatal events and associated postnatal neurological outcome. Fetuses with an abnormal CPR that are appropriate for gestational age or have late-onset SGA (>34 weeks of gestation) have a higher incidence of fetal distress in labor requiring emergency cesarean delivery, a lower cord pH, and an increased admission rate to the newborn intensive care unit when compared with fetuses with a normal CPR. Fetuses with early-onset SGA (<34 weeks of gestation) with an abnormal CPR have a higher incidence of the following when compared with fetuses with a normal CPR: (1) lower gestational age at birth, (2) lower mean birthweight, (3) lower birthweight centile, (4) birthweight less than the 10th centile, (5) higher rate of cesarean delivery for fetal distress in labor, (6) higher rate of Apgar scores less than 7 at 5 minutes, (7) an increased rate of neonatal acidosis, (8) an increased rate of newborn intensive care unit admissions, (9) higher rate of adverse neonatal outcome, and (10) a greater incidence of perinatal death. The CPR is also an earlier predictor of adverse outcome than the biophysical profile, umbilical artery, or middle cerebral artery. In conclusion, the CPR should be considered as an assessment tool in fetuses undergoing third-trimester ultrasound examination, irrespective of the findings of the individual umbilical artery and middle cerebral artery measurements. A CPR calculator is available at http://www.ajog.org/pb/assets/raw/Health%20Advance/journals/ymob/CPR/index.htm.
Collapse
|
17
|
Predojević M, Talić A, Stanojević M, Kurjak A, Salihagić Kadić A. Assessment of motoric and hemodynamic parameters in growth restricted fetuses – case study. J Matern Fetal Neonatal Med 2013; 27:247-51. [DOI: 10.3109/14767058.2013.807241] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
18
|
Hernandez-Andrade E, Serralde JAB, Cruz-Martinez R. Can anomalies of fetal brain circulation be useful in the management of growth restricted fetuses? Prenat Diagn 2012; 32:103-12. [PMID: 22418951 DOI: 10.1002/pd.2913] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Assessment of the fetal cerebral circulation provides important information on the hemodynamic changes associated with chronic hypoxia and intrauterine growth restriction. Despite the incorporation of new US parameters, the landmark for the fetal brain hemodynamic evaluation is still the middle cerebral artery. However, new vascular territories, such as the anterior and posterior cerebral arteries, might provide additional information on the onset of the brain sparing effect. The fractional moving blood volume estimation and three-dimensional power Doppler ultrasound indices are new techniques that seem to be promising in identifying cases at earlier stages of vascular deterioration; still, they are not available for clinical application and more information is needed on the reproducibility and advantages of three-dimensional power Doppler ultrasound blood flow indices. In the past, the brain sparing effect was considered as a protective mechanism; however, recent information challenges this concept. There is growing evidence of an association between brain sparing effect and increased risk of abnormal neurodevelopment after birth. Even in mild late-onset intrauterine growth restriction affected fetuses with normal umbilical artery blood flow, increased cerebral blood perfusion can be associated with a substantial risk of abnormal neuroadaptation and neurodevelopment during childhood.
Collapse
Affiliation(s)
- Edgar Hernandez-Andrade
- Maternal Fetal Medicine Department, National Institute of Perinatology, Mexico City, Mexico.
| | | | | |
Collapse
|
19
|
Koos BJ. Adenosine A₂a receptors and O₂ sensing in development. Am J Physiol Regul Integr Comp Physiol 2011; 301:R601-22. [PMID: 21677265 DOI: 10.1152/ajpregu.00664.2010] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Reduced mitochondrial oxidative phosphorylation, via activation of adenylate kinase and the resulting exponential rise in the cellular AMP/ATP ratio, appears to be a critical factor underlying O₂ sensing in many chemoreceptive tissues in mammals. The elevated AMP/ATP ratio, in turn, activates key enzymes that are involved in physiologic adjustments that tend to balance ATP supply and demand. An example is the conversion of AMP to adenosine via 5'-nucleotidase and the resulting activation of adenosine A(₂A) receptors, which are involved in acute oxygen sensing by both carotid bodies and the brain. In fetal sheep, A(₂A) receptors associated with carotid bodies trigger hypoxic cardiovascular chemoreflexes, while central A(₂A) receptors mediate hypoxic inhibition of breathing and rapid eye movements. A(₂A) receptors are also involved in hypoxic regulation of fetal endocrine systems, metabolism, and vascular tone. In developing lambs, A(₂A) receptors play virtually no role in O₂ sensing by the carotid bodies, but brain A(₂A) receptors remain critically involved in the roll-off ventilatory response to hypoxia. In adult mammals, A(₂A) receptors have been implicated in O₂ sensing by carotid glomus cells, while central A(₂A) receptors likely blunt hypoxic hyperventilation. In conclusion, A(₂A) receptors are crucially involved in the transduction mechanisms of O₂ sensing in fetal carotid bodies and brains. Postnatally, central A(₂A) receptors remain key mediators of hypoxic respiratory depression, but they are less critical for O₂ sensing in carotid chemoreceptors, particularly in developing lambs.
Collapse
Affiliation(s)
- Brian J Koos
- Department of Obstetrics and Gynecology; Brain Research Institute, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, California, USA.
| |
Collapse
|
20
|
Predojević M, Stanojević M, Vasilj O, Kadić AS. Prenatal and postnatal neurological evaluation of a fetus and newborn from pregnancy complicated with IUGR and fetal hypoxemia. J Matern Fetal Neonatal Med 2010; 24:764-7. [DOI: 10.3109/14767058.2010.511350] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|