1
|
Hleba L, Hlebova M, Kovacik A, Petrova J, Maskova Z, Cubon J, Massanyi P. Use of MALDI-TOF MS to Discriminate between Aflatoxin B1-Producing and Non-Producing Strains of Aspergillus flavus. Molecules 2022; 27:molecules27227861. [PMID: 36431961 PMCID: PMC9692738 DOI: 10.3390/molecules27227861] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/09/2022] [Accepted: 11/11/2022] [Indexed: 11/16/2022] Open
Abstract
Aflatoxin B1 (AFB1) is one of the most toxic mycotoxins. One of the producers of AFB1 is Aspergillus flavus. Therefore, its rapid identification plays a key role in various sectors of the food and feed industry. MALDI-TOF mass spectrometry is one of the fastest and most accurate methods today. Therefore, the aim of this research was to develop the rapid identification of producing and non-producing strains of A. flavus based on the entire mass spectrum. To accomplish the main goal a different confirmatory MALDI-TOF MS and TLC procedures such as direct AFB1 identification by scraping from TLC plates, A. flavus mycelium, nutrient media around A. flavus growth, and finally direct AFB1 identification from infected wheat and barley grains had to be conducted. In this experiment, MALDI-TOF mass spectrometry with various modifications was the main supporting technology. All confirmatory methods confirmed the presence of AFB1 in the samples of aflatoxin-producing strains of A. flavus and vice versa; AFB1 was not detected in the case of non-producing strains. Entire mass spectra (from 2 to 20 kDa) of aflatoxin-producing and non-producing A. flavus strains were collected, statistically analyzed and clustered. An in-depth analysis of the obtained entire mass spectra showed differences between AFB1-producing and non-producing strains of A. flavus. Statistical and cluster analysis divided AFB1-producing and non-producing strains of A. flavus into two monasteries. The results indicate that it is possible to distinguish between AFB1 producers and non-producers by comparing the entire mass spectra using MALDI-TOF MS. Finally, we demonstrated that if there are established local AFB1-producing and non-producing strains of A. flavus, the entire mass spectrum database identification of aflatoxigenic A. flavus strains can be even faster and cheaper, without the need to identify the toxin itself.
Collapse
Affiliation(s)
- Lukas Hleba
- Faculty of Biotechnology and Food Sciences, Institute of Biotechnology, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
- Correspondence:
| | - Miroslava Hlebova
- Department of Biology, Faculty of Natural Sciences, University of Ss. Cyril and Methodius, Nám. J. Herdu 2, 917 01 Trnava, Slovakia
| | - Anton Kovacik
- Faculty of Biotechnology and Food Sciences, Institute of Applied Biology, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
| | - Jana Petrova
- Faculty of Biotechnology and Food Sciences, Institute of Biotechnology, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
| | - Zuzana Maskova
- Faculty of Biotechnology and Food Sciences, Institute of Biotechnology, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
| | - Juraj Cubon
- Faculty of Biotechnology and Food Sciences, Institute of Food Sciences, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
| | - Peter Massanyi
- Faculty of Biotechnology and Food Sciences, Institute of Applied Biology, Slovak University of Agriculture in Nitra, Tr. Andreja Hlinku 2, 949 76 Nitra, Slovakia
| |
Collapse
|
2
|
Anwer R, Darami H, Almarri FK, Albogami MA, Alahaydib F. MALDI-TOF MS for Rapid Analysis of Bacterial Pathogens Causing Urinary Tract Infections in the Riyadh Region. Diseases 2022; 10:diseases10040078. [PMID: 36278577 PMCID: PMC9590002 DOI: 10.3390/diseases10040078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 09/22/2022] [Accepted: 09/27/2022] [Indexed: 12/02/2022] Open
Abstract
The successful treatment of bacterial disease is relied on selecting a suitable drug based on the type of bacteria and antimicrobial susceptibility testing. The study’s objective was to identify bacterial isolates from urine samples of patients from the community, followed by antimicrobial susceptibility testing of the isolated bacteria. A total of seventy urine samples were received in the clinical microbiology laboratory; out of which 18 culture-positive cultures and by direct identification using MALDI-TOF MS (Matrix Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry) were identified. Of 18 identified bacteria, 17 (94%) were pathogenic. The culture demonstrated that the major species detected in urine samples were Escherichia coli, Klebsiella pneumoniae, Enterococcus faecalis, and Aeromonas caviae. E. coli (72.2%) was the most common bacterium retrieved from urine samples followed by K. pneumoniae (16.6%). Interestingly, all the isolates, except Enterococcus faecalis, were resistant to erythromycin. The isolates 8 of 13 (61.5%) were resistant to both of the cotrimoxazole and tetracycline. We performed MLST (Multi-locus Sequence Typing) typing of 13 E. coli isolates to study their genetic relatedness and diversity. MLST typing of E. coli showed a total of nine different STs (Sequence Types), which showed the diversity among them. ST 129 was the most common ST found in three E. coli isolates. In our study, two isolates with ST 1126 and ST 1432 represented the global clonal complex 155. MALDI-TOF MS provided dependable results for identifying the bacteria up to species level from urine samples by indirect culture methods. Such local surveillances are highly recommended for empirical therapy awareness and determining isolates’ level of resistance.
Collapse
Affiliation(s)
- Razique Anwer
- Department of Pathology, College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia
- Correspondence:
| | - Hassan Darami
- Department of OB & Gyne, College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia
| | - Firas K. Almarri
- College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia
| | - Mazen A. Albogami
- College of Medicine, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia
| | - Faisal Alahaydib
- Medical Center, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 13317-4233, Saudi Arabia
| |
Collapse
|
3
|
Core-shell MOF@COFs used as an adsorbent and matrix for the detection of nonsteroidal anti-inflammatory drugs by MALDI-TOF MS. Mikrochim Acta 2021; 188:179. [PMID: 33914148 DOI: 10.1007/s00604-021-04832-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 04/19/2021] [Indexed: 10/21/2022]
Abstract
A core-shell material (UiO@TapbTp) has been developed as an adsorbent and matrix to detect nonsteroidal anti-inflammatory drugs (NSAIDS) by matrix laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in complex samples. The hybrid material is prepared by growing covalent organic framework (COF, TapbTp) layers in situ on an amino-modified metal-organic framework (MOF, UiO-66-NH2). The combination of the MOF and COF overcomes their individual shortcomings and integrates both of their advantages. Compared with the bare COF and MOF, the core-shell composite exhibits improved enrichment ability and matrix performance. With the help of pre-enrichment under optimized conditions, the limits of detection (LODs) for ketoprofen, naproxen, and aspirin are reduced by nearly 1000 times, with values of 0.001 mg L-1, 0.010 mg L-1, and 0.001 mg L-1, respectively, and the relative standard deviations (RSDs) are all below 12.35%. The good recoveries (84.8-118%) in (spiked) saliva and environmental water sample further verify the applicability of the method in complex samples.
Collapse
|
4
|
New Methodology for the Identification of Metabolites of Saccharides and Cyclitols by Off-Line EC-MALDI-TOF-MS. Int J Mol Sci 2020; 21:ijms21155265. [PMID: 32722273 PMCID: PMC7432413 DOI: 10.3390/ijms21155265] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/18/2020] [Accepted: 07/22/2020] [Indexed: 12/20/2022] Open
Abstract
A combination of electrochemistry (EC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (off-line EC-MALDI-TOF-MS) was applied for determination of the studied biologically active compounds (D-glucose, D-fructose, D-galactose, D-pinitol, L-chiro-inositol, and myo-inositol) and their possible electrochemical metabolites. In this work, boron-doped diamond electrode (BDD) was used as a working electrode. MALDI-TOF-MS experiments were carried out (both in positive and negative ion modes and using two matrices) to identify the structures of electrochemical products. This was one of the first applications of the EC system for the generation of electrochemical products produced from saccharides and cyclitols. Moreover, exploratory data analysis approaches (correlation networks, hierarchical cluster analysis, weighted plots) were used in order to present differences/similarities between the obtained spectra, regarding the class of analyzed compounds, ionization modes, and used matrices. This work presents the investigation and comparison of fragmentation patterns of sugars, cyclitols, and their respective products generated through the electrochemistry (EC) process.
Collapse
|
5
|
Norouz Dizaji A, Ding D, Kutsal T, Turk M, Kong D, Piskin E. In vivo imaging/detection of MRSA bacterial infections in mice using fluorescence labelled polymeric nanoparticles carrying vancomycin as the targeting agent. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2019; 31:293-309. [PMID: 31762403 DOI: 10.1080/09205063.2019.1692631] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
This study aims to develop fluorescence labelled polymeric nanoparticle (NP) carrying vancomycin as the targeting agent for in vivo imaging of Methicillin-resistant Staphylococcus aureus bacterial infections in animal models. Maleimide functionalized 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-N-[maleimide (polyethylene glycol)-2000] as the main was carrier matrix to prepare the NPs. A fluorescence probe, namely, poly[9,9'-bis (6″-N,N,N-trimethylammonium) hexyl) fluorene-co-alt-4,7-(2,1,3-benzothiadiazole) dibromide] was encapsulated within these NPs by ultrasonication successfully. UV-Vis spectro- photometry of the NPs showed the characteristic shifting on the peak of conjugated polymers indicating successful packaging of this compound with lipid bilayers in nanoscales. Zeta-sizer and TEM analysis showed that the prepared NPs have a diameter of 80-100 nm in a narrow size distribution. Thiolated vancomycin was synthesized and attached to the NPs as the targeting agent. FTIR and MALDI-TOF spectroscopy analysis confirmed the immobilization. The specific targeting properties of the vancomycin conjugated NPs to the target bacteria were first confirmed in in vitro bacterial cultures in which Escherichia coli was the non-target bacteria - using confocal microscopy and TEM. Imaging of bacterial infections in vivo was investigated in mice model using a non-invasive live animal fluorescence imaging technique. The results confirmed that bacterial infections can be detected using these novel polymeric NPs carrying fluorescence probes for imaging and vancomycin as the targeting agent - in vivo successfully.
Collapse
Affiliation(s)
- Araz Norouz Dizaji
- Bioengineering Division, Institute of Graduate Studies, Hacettepe University, Beytepe, Ankara, Turkey
| | - Dan Ding
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Bioactive Materials, Ministry of Education, and College of Life Sciences, Nankai University, Tianjin, China
| | - Tulin Kutsal
- Faculty of Engineering, Chemical Engineering Department, Hacettepe University, Beytepe, Ankara, Turkey
| | - Mustafa Turk
- Faculty of Engineering, Department of Bioengineering, Kirikkale University, Yahsihan, Kirikkale, Turkey
| | - Deling Kong
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Bioactive Materials, Ministry of Education, and College of Life Sciences, Nankai University, Tianjin, China
| | - Erhan Piskin
- Bioengineering Division, Institute of Graduate Studies, Hacettepe University, Beytepe, Ankara, Turkey.,NanoBMT: Nanobiyomedtek Biyomedikal ve Biyoteknoloji San.Tic.Ltd.Şti, Bilkent, Ankara, Turkey
| |
Collapse
|
6
|
Winter M, Bretschneider T, Thamm S, Kleiner C, Grabowski D, Chandler S, Ries R, Kley JT, Fowler D, Bartlett C, Binetti R, Broadwater J, Luippold AH, Bischoff D, Büttner FH. Chemical Derivatization Enables MALDI-TOF-Based High-Throughput Screening for Microbial Trimethylamine (TMA)-Lyase Inhibitors. SLAS DISCOVERY 2019; 24:766-777. [PMID: 31059309 DOI: 10.1177/2472555219838216] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Microbial-dependent trimethylamine (TMA) generation from dietary precursors such as choline was recently linked to cardiovascular diseases (CVDs) as well as chronic kidney disease (CKD). Inhibition of TMA-generating enzymes in gut bacteria would be an innovative approach to treat these diseases. The potential to accurately quantify secreted TMA levels highlights the capacity of mass spectrometry (MS) for tracking microbial TMA-lyase activity. However, high-throughput screening (HTS) by conventional MS instrumentation is hampered by limited sample throughput. Recent advancement in liquid handling and instrumentation of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS provides an HTS-compatible MS technology. The deciphering of enzymatic reactions using this label-free readout has been successfully applied but has thus far been limited to peptide/protein-centric activity assays. Here, we demonstrate the versatile applicability of MALDI-TOF by tracking a small molecule within a highly complex sample background. The key to success for this concept was chemical derivatization of the target molecule enabling quantitative assessment of microbial TMA formation. Further, its potential was demonstrated in a side-by-side comparison to RapidFire-MS in a primary screen and subsequent dose-response experiments. Overall, the established assay enables the screening for microbial TMA-lyase inhibitors and serves as a proof of concept for the applicability of MALDI-TOF for demanding assay concepts per se.
Collapse
Affiliation(s)
- Martin Winter
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Tom Bretschneider
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Sven Thamm
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Carola Kleiner
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Daniel Grabowski
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Sarah Chandler
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Robert Ries
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Jörg T Kley
- 2 Medicinal Chemistry, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Danielle Fowler
- 3 Cardiometabolic Diseases Research, Boehringer Ingelheim Pharmaceuticals, Ridgefield, CT, USA
| | - Christina Bartlett
- 3 Cardiometabolic Diseases Research, Boehringer Ingelheim Pharmaceuticals, Ridgefield, CT, USA
| | - Ralph Binetti
- 4 Cancer Immunology & Immune Modulation, Boehringer Ingelheim Pharmaceuticals, Ridgefield, CT, USA
| | - John Broadwater
- 3 Cardiometabolic Diseases Research, Boehringer Ingelheim Pharmaceuticals, Ridgefield, CT, USA
| | - Andreas H Luippold
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Daniel Bischoff
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| | - Frank H Büttner
- 1 Drug Discovery Sciences, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach an der Riß, Germany
| |
Collapse
|
7
|
Elzahhar P, Belal ASF, Elamrawy F, Helal NA, Nounou MI. Bioconjugation in Drug Delivery: Practical Perspectives and Future Perceptions. Methods Mol Biol 2019; 2000:125-182. [PMID: 31148014 DOI: 10.1007/978-1-4939-9516-5_11] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
For the past three decades, pharmaceutical research has been mainly converging to novel carrier systems and nanoparticulate colloidal technologies for drug delivery, such as nanoparticles, nanospheres, vesicular systems, liposomes, or nanocapsules to impart novel functions and targeting abilities. Such technologies opened the gate towards more sophisticated and effective multi-acting platform(s) which can offer site-targeting, imaging, and treatment using a single multifunctional system. Unfortunately, such technologies faced major intrinsic hurdles including high cost, low stability profile, short shelf-life, and poor reproducibility across and within production batches leading to harsh bench-to-bedside transformation.Currently, pharmaceutical industry along with academic research is investing heavily in bioconjugate structures as an appealing and advantageous alternative to nanoparticulate delivery systems with all its flexible benefits when it comes to custom design and tailor grafting along with avoiding most of its shortcomings. Bioconjugation is a ubiquitous technique that finds a multitude of applications in different branches of life sciences, including drug and gene delivery applications, biological assays, imaging, and biosensing.Bioconjugation is simple, easy, and generally a one-step drug (active pharmaceutical ingredient) conjugation, using various smart biocompatible, bioreducible, or biodegradable linkers, to targeting agents, PEG layer, or another drug. In this chapter, the different types of bioconjugates, the techniques used throughout the course of their synthesis and characterization, as well as the well-established synthetic approaches used for their formulation are presented. In addition, some exemplary representatives are outlined with greater emphasis on the practical tips and tricks of the most prominent techniques such as click chemistry, carbodiimide coupling, and avidin-biotin system.
Collapse
Affiliation(s)
- Perihan Elzahhar
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Alexandria University, Alexandria, Egypt
| | - Ahmed S F Belal
- Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Alexandria University, Alexandria, Egypt
| | - Fatema Elamrawy
- Department of Pharmaceutics, Faculty of Pharmacy, Alexandria University, Alexandria, Egypt
| | - Nada A Helal
- Department of Pharmaceutics, Faculty of Pharmacy, Alexandria University, Alexandria, Egypt
| | - Mohamed Ismail Nounou
- Department of Pharmaceutical Sciences, School of Pharmacy & Physician Assistant Studies (SOPPAS), University of Saint Joseph (USJ), Hartford, CT, USA.
| |
Collapse
|
8
|
Qin X, Wang X. Quantification of nucleotides and their sugar conjugates in biological samples: Purposes, instruments and applications. J Pharm Biomed Anal 2018; 158:280-287. [PMID: 29902692 DOI: 10.1016/j.jpba.2018.06.013] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 06/06/2018] [Accepted: 06/07/2018] [Indexed: 01/23/2023]
Abstract
Nucleotides and their sugar conjugates are fundamental molecules in life, participating in processes of DNA/RNA composition, cell wall build-up, glycosylation reactions, and signal conduction. Therefore, the quantification of these compounds in biological samples significantly benefits the understanding of their functions. However, nucleotides and nucleotide sugars are extremely hydrophilic, causing bad retention and peak symmetry on regular C18 chromatographic columns. To solve this problem, ion-pair (IP) chromatography, ion-exchange (IE) chromatography and hydrophilic interaction chromatography (HILIC) were applied, of which differentiated mechanisms were utilized to increase the retention of the analytes on the stationary phases. IP-HPLC and HILIC were convenient for coupling with many kinds of detectors (ultraviolet, UV or mass spectrometry, MS). Combining these two kinds of techniques, the advantages of better separation and retention were increased, while disadvantages like irreversible adsorption by stationary phases were greatly decreased. Due to the high concentrations of nonvolatile buffer salts used, IE-HPLC was not suitable for MS detectors. Protein precipitation and solid phase extraction were the common methods for sample treatment in the analysis of nucleotides and nucleotide sugars. By carefully optimizing the LCUV or LCMS conditions, high sensitivities could be achieved, and the methods could be applied to the analysis of many kinds of biological samples (cells, tissues, plants, bacteria, etc.). Developing new analyzing techniques may help the utilization of nucleotides and nucleotide sugars in the diagnosis and therapy of diseases.
Collapse
Affiliation(s)
- Xuan Qin
- Shanghai Key Laboratory of Regulatory Biology, Institute of Biomedical Sciences and School of Life Sciences, East China Normal University, Shanghai, China
| | - Xin Wang
- Shanghai Key Laboratory of Regulatory Biology, Institute of Biomedical Sciences and School of Life Sciences, East China Normal University, Shanghai, China.
| |
Collapse
|
9
|
Bailey GA, Fogg DE. Confronting Neutrality: Maximizing Success in the Analysis of Transition-Metal Catalysts by MALDI Mass Spectrometry. ACS Catal 2016. [DOI: 10.1021/acscatal.6b01105] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Gwendolyn A. Bailey
- Center for Catalysis Research & Innovation and Department of Chemistry and Biological Sciences, University of Ottawa, Ottawa, Ontario, Canada K1N 6N5
| | - Deryn E. Fogg
- Center for Catalysis Research & Innovation and Department of Chemistry and Biological Sciences, University of Ottawa, Ottawa, Ontario, Canada K1N 6N5
| |
Collapse
|
10
|
|
11
|
Abstract
Sensitive and reliable analysis of endogenous compounds is critically important for many physiological and pathological studies. Methods based on LC–MS have progressed to become the method of choice for analyzing endogenous compounds. However, the analysis can be challenging due to various factors, including inherent low concentrations in biological samples, low ionization efficiency, undesirable chromatographic behavior and interferences of complex biological. The integration of chemical derivatization with LC–MS could enhance its capabilities in sensitivity and selectivity, and extend its application to a wider range of analytes. In this article, we will review the derivatization strategies in the LC–MS analysis of various endogenous compounds, and provide applications highlighting the impact of these important techniques in the evaluation of pathological events.
Collapse
|
12
|
Zhu W, Wang HY, Zhang J, Zhang S, Guo Y. Processed eggshell as sample carrier for rapid analysis of organometallic compounds by desorption electrospray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:972-977. [PMID: 28338278 DOI: 10.1002/jms.3608] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2015] [Revised: 04/21/2015] [Accepted: 04/21/2015] [Indexed: 06/06/2023]
Affiliation(s)
- Wei Zhu
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Hao-Yang Wang
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Junting Zhang
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Shusheng Zhang
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| | - Yinlong Guo
- National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, 345 Lingling Road, Shanghai, 200032, China
| |
Collapse
|
13
|
Borisov RS, Zhilyaev DI, Polovkov NY, Zaikin VG. Simple approach to derivatization of alcohols and phenols for the analysis by matrix(surface)-assisted laser desorption/ionization time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2014; 28:2231-2236. [PMID: 25279736 DOI: 10.1002/rcm.7008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Revised: 07/31/2014] [Accepted: 07/31/2014] [Indexed: 06/03/2023]
Abstract
RATIONALE Direct analysis of hydroxyl-containing compounds by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) methods is not always possible due to the neutral character of analytes. The suggested fixed-charge derivatization may increase the ionization efficiency for various alcohols and phenols in specific matrix- and surface-activated LDI conditions. METHODS Aliphatic and steroid alcohols, as well as chlorophenols, were converted into various ammonioacetyl derivatives, containing a covalently bonded charged group, by reaction with bromoacetyl chloride and amine-type compounds such as triethylamine, pyridine or quinoline. The derivatives are suitable for MALDI-time-of-flight (TOF)MS analysis. RESULTS Triethylammoniumacetyl, pyridyliumacetyl and quinoliniumacetyl derivatives were prepared from aliphatic alcohols, some sterols and chlorinated phenols in one stage with quantitative yields. The derivatives produced characteristic MALDI and SALDI mass spectra. CONCLUSIONS The suggested derivatization approach for the modification of alcohols is simple and does not require any expensive reagents. The derivatives include a fixed charge and produce intense signals in MALDI (preferentially non-acidic matrices) and matrix-free SALDI (nanostructured target) conditions. Corresponding mass spectra are suitable for the determination of molecular mass and profiling of alcohols.
Collapse
Affiliation(s)
- Roman S Borisov
- A.V. Topchiev Institute of Petrochemical Synthesis, Russian Academy of Sciences, Leninsky pr. 29, 119991, Moscow, Russian Federation
| | | | | | | |
Collapse
|
14
|
N-alkylpyridinium quaternization combined with liquid chromatography–electrospray ionization-tandem mass spectrometry: A highly sensitive method to quantify fatty alcohols in thyroid tissues. Anal Chim Acta 2014; 849:19-26. [DOI: 10.1016/j.aca.2014.08.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2014] [Revised: 08/12/2014] [Accepted: 08/17/2014] [Indexed: 11/18/2022]
|
15
|
Gaucher-Wieczorek F, Guérineau V, Touboul D, Thétiot-Laurent S, Pelissier F, Badet-Denisot MA, Badet B, Durand P. Evaluation of synthase and hemisynthase activities of glucosamine-6-phosphate synthase by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Anal Biochem 2014; 458:61-5. [DOI: 10.1016/j.ab.2014.04.033] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 04/26/2014] [Accepted: 04/28/2014] [Indexed: 11/17/2022]
|
16
|
Albalat A, Stalmach A, Bitsika V, Siwy J, Schanstra JP, Petropoulos AD, Vlahou A, Jankowski J, Persson F, Rossing P, Jaskolla TW, Mischak H, Husi H. Improving peptide relative quantification in MALDI-TOF MS for biomarker assessment. Proteomics 2014; 13:2967-75. [PMID: 23943474 DOI: 10.1002/pmic.201300100] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Revised: 06/19/2013] [Accepted: 07/13/2013] [Indexed: 12/29/2022]
Abstract
Proteomic profiling by MALDI-TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI-TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI-TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI-TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).
Collapse
Affiliation(s)
- Amaya Albalat
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, Glasgow, Scotland, UK
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Eriksson C, Masaki N, Yao I, Hayasaka T, Setou M. MALDI Imaging Mass Spectrometry-A Mini Review of Methods and Recent Developments. Mass Spectrom (Tokyo) 2013; 2:S0022. [PMID: 24349941 DOI: 10.5702/massspectrometry.s0022] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2012] [Accepted: 01/23/2013] [Indexed: 12/16/2022] Open
Abstract
As the only imaging method available, Imaging Mass Spectrometry (IMS) can determine both the identity and the distribution of hundreds of molecules on tissue sections, all in one single run. IMS is becoming an established research technology, and due to recent technical and methodological improvements the interest in this technology is increasing steadily and within a wide range of scientific fields. Of the different IMS methods available, matrix-assisted laser desorption/ionization (MALDI) IMS is the most commonly employed. The course at IMSC 2012 in Kyoto covered the fundamental principles and techniques of MALDI-IMS, assuming no previous experience in IMS. This mini review summarizes the content of the one-day course and describes some of the most recent work performed within this research field.
Collapse
Affiliation(s)
- Cecilia Eriksson
- Department of Cell Biology and Anatomy, Hamamatsu University School of Medicine ; Medical Mass Spectrometry, Department of Pharmaceutical Biosciences, Uppsala University
| | - Noritaka Masaki
- Department of Cell Biology and Anatomy, Hamamatsu University School of Medicine
| | - Ikuko Yao
- Department of Medical Chemistry, Kansai Medical University
| | - Takahiro Hayasaka
- Department of Cell Biology and Anatomy, Hamamatsu University School of Medicine
| | - Mitsutoshi Setou
- Department of Cell Biology and Anatomy, Hamamatsu University School of Medicine
| |
Collapse
|