1
|
Bissmeyer SRS, Goldsworthy RL. Combining Place and Rate of Stimulation Improves Frequency Discrimination in Cochlear Implant Users. Hear Res 2022; 424:108583. [PMID: 35930901 PMCID: PMC10849775 DOI: 10.1016/j.heares.2022.108583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 06/20/2022] [Accepted: 07/21/2022] [Indexed: 11/04/2022]
Abstract
In the auditory system, frequency is represented as tonotopic and temporal response properties of the auditory nerve. While these response properties are inextricably linked in normal hearing, cochlear implants can separately excite tonotopic location and temporal synchrony using different electrodes and stimulation rates, respectively. This separation allows for the investigation of the contributions of tonotopic and temporal cues for frequency discrimination. The present study examines frequency discrimination in adult cochlear implant users as conveyed by electrode position and stimulation rate, separately and combined. The working hypothesis is that frequency discrimination is better provided by place and rate cues combined compared to either cue alone. This hypothesis was tested in two experiments. In the first experiment, frequency discrimination needed for melodic contour identification was measured for frequencies near 100, 200, and 400 Hz using frequency allocation modeled after clinical processors. In the second experiment, frequency discrimination for pitch ranking was measured for frequencies between 100 and 1600 Hz using an experimental frequency allocation designed to provide better access to place cues. The results of both experiments indicate that frequency discrimination is better with place and rate cues combined than with either cue alone. These results clarify how signal processing for cochlear implants could better encode frequency into place and rate of electrical stimulation. Further, the results provide insight into the contributions of place and rate cues for pitch.
Collapse
Affiliation(s)
- Susan R S Bissmeyer
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, United States; Auditory Research Center, Health Research Association, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo Street Suite 326, Los Angeles, CA 90033, United States.
| | - Raymond L Goldsworthy
- Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, CA, United States; Auditory Research Center, Health Research Association, Caruso Department of Otolaryngology, Keck School of Medicine, University of Southern California, 1640 Marengo Street Suite 326, Los Angeles, CA 90033, United States
| |
Collapse
|
2
|
Hu H, Klug J, Dietz M. Simulation of ITD-Dependent Single-Neuron Responses Under Electrical Stimulation and with Amplitude-Modulated Acoustic Stimuli. J Assoc Res Otolaryngol 2022; 23:535-550. [PMID: 35334001 PMCID: PMC9437183 DOI: 10.1007/s10162-021-00823-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 11/03/2021] [Indexed: 11/30/2022] Open
Abstract
Interaural time difference (ITD) sensitivity with cochlear implant stimulation is remarkably similar to envelope ITD sensitivity using conventional acoustic stimulation. This holds true for human perception, as well as for neural response rates recorded in the inferior colliculus of several mammalian species. We hypothesize that robust excitatory-inhibitory (EI) interaction is the dominant mechanism. Therefore, we connected the same single EI-model neuron to either a model of the normal acoustic auditory periphery or to a model of the electrically stimulated auditory nerve. The model captured most features of the experimentally obtained response properties with electric stimulation, such as the shape of rate-ITD functions, the dependence on stimulation level, and the pulse rate or modulation-frequency dependence. Rate-ITD functions with high-rate, amplitude-modulated electric stimuli were very similar to their acoustic counterparts. Responses obtained with unmodulated electric pulse trains most resembled acoustic filtered clicks. The fairly rapid decline of ITD sensitivity at rates above 300 pulses or cycles per second is correctly simulated by the 3.1-ms time constant of the inhibitory post-synaptic conductance. As the model accounts for these basic properties, it is expected to help in understanding and quantifying the binaural hearing abilities with electric stimulation when integrated in bigger simulation frameworks.
Collapse
Affiliation(s)
- Hongmei Hu
- Department of Medical Physics and Acoustics and Cluster of Excellence "Hearing4all", University of Oldenburg, 26129, Oldenburg, Germany.
| | - Jonas Klug
- Department of Medical Physics and Acoustics and Cluster of Excellence "Hearing4all", University of Oldenburg, 26129, Oldenburg, Germany
| | - Mathias Dietz
- Department of Medical Physics and Acoustics and Cluster of Excellence "Hearing4all", University of Oldenburg, 26129, Oldenburg, Germany
| |
Collapse
|
3
|
Seebacher J, Franke-Trieger A, Weichbold V, Zorowka P, Stephan K. Improved interaural timing of acoustic nerve stimulation affects sound localization in single-sided deaf cochlear implant users. Hear Res 2018; 371:19-27. [PMID: 30439571 DOI: 10.1016/j.heares.2018.10.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 09/11/2018] [Accepted: 10/26/2018] [Indexed: 11/17/2022]
Abstract
The main impairment associated with single-sided deafness (SSD) is the loss of binaural hearing. Currently, the most effective treatment to compensate for this deficit is to supply patients suffering from SSD with a cochlear implant (CI) in the deaf ear. With this approach binaural hearing abilities can be restored to a certain extent, which is expressed in an improvement in such patients with regard to sound source localization and speech comprehension in noise after receipt of a CI. However, binaural performance of these listeners does not reach the level of normal-hearing listeners. One of the reasons for this might be that the electrical stimulation via CI and the physiological stimulation via the intact ear are not synchronized: the CI transmits the information to the auditory nerve with different timing than does the intact inner ear. As a result, there is a timing mismatch of the information transfer between the left and the right side, which may account for the limited binaural performance. The effective mismatch in timing depends on the CI system because of different stimulation strategies implemented in devices from different manufacturers. For the particular CI device used in this study (MED-EL Mi1000/Mi1200) electrical stimulation led to faster activation of the auditory nerve than natural for a wide frequency range. In particular, electrical stimulation was about 1 to up to 2 ms ahead of time for frequencies above 1.5 kHz. Hence, it was hypothesized that information transfer between the left and the right ear can be tuned by delaying the CI signal. The goal of the present study was to investigate whether such a delay in the CI signal affects binaural performance of CI users with SSD. For this purpose, sound source localization and speech perception in noise were tested in a sample of 12 CI users with SSD (mean age 51 ± 12 years). The tests were performed for four different delay times of the CI signal applied spontaneously (0.5, 1, 2 and 4 ms) and for the base line condition "no delay" in the CI signal (i.e. everyday use). It was found that delaying the signal had a significant impact on sound source localization. Speech perception in noise was affected, but less pronounced than was sound localization. Regarding sound source localization, a signal delay of 1 ms applied to this particular CI device produced the best performance in our patients. It is concluded that improving the synchronisation between the CI-transferred signal and the naturally transferred signal could increase binaural hearing performance in CI users with SSD.
Collapse
Affiliation(s)
- J Seebacher
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria.
| | - A Franke-Trieger
- Saxonian Cochlear Implant Center, Department of Otorhinolaryngology, Technical University of Dresden, Germany
| | - V Weichbold
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| | - P Zorowka
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| | - K Stephan
- Department for Hearing, Speech and Voice Disorders, Medical University of Innsbruck, Austria
| |
Collapse
|
4
|
Gaudrain E, Deeks JM, Carlyon RP. Temporal Regularity Detection and Rate Discrimination in Cochlear-Implant Listeners. J Assoc Res Otolaryngol 2017; 18:387-397. [PMID: 27687041 PMCID: PMC5352605 DOI: 10.1007/s10162-016-0586-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2015] [Accepted: 09/05/2016] [Indexed: 11/25/2022] Open
Abstract
Cochlear implants (CIs) convey fundamental-frequency information using primarily temporal cues. However, temporal pitch perception in CI users is weak and, when measured using rate discrimination tasks, deteriorates markedly as the rate increases beyond 300 pulses-per-second. Rate pitch may be weak because the electrical stimulation of the surviving neural population of the implant recipient may not allow accurate coding of inter-pulse time intervals. If so, this phenomenon should prevent listeners from detecting when a pulse train is physically temporally jittered. Performance in a jitter detection task was compared to that in a rate-pitch discrimination task. Stimuli were delivered using direct stimulation in cochlear implants, on a mid-array and an apical electrode, and at two different rates (100 and 300 pps). Average performance on both tasks was worse at the higher pulse rate and did not depend on electrode. However, there was a large variability across and within listeners that did not correlate between the two tasks, suggesting that rate-pitch judgement and regularity detection are to some extent limited by task-specific processes. Simulations with filtered pulse trains presented to NH listeners yielded broadly similar results, except that, for the rate discrimination task, the difference between performance with 100- and 300-pps base rates was smaller than observed for CI users.
Collapse
Affiliation(s)
- Etienne Gaudrain
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Road, CB2 7EF Cambridge, UK
- CNRS UMR 5292, Lyon Neuroscience Research Center, Auditory Cognition and Psychoacoustics, Université Lyon 1, 50 av. Tony Garnier, 69366 Lyon Cedex 7, France
- Department of Otorhinolaryngology, University Medical Center Groningen-University of Groningen, Huispostcode BB20, PO Box 30.001, 9700 RB Groningen, Netherlands
| | - John M. Deeks
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Road, CB2 7EF Cambridge, UK
| | - Robert P. Carlyon
- MRC Cognition and Brain Sciences Unit, 15 Chaucer Road, CB2 7EF Cambridge, UK
| |
Collapse
|
5
|
Monaghan JJM, Bleeck S, McAlpine D. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates. Trends Hear 2015; 19:2331216515619331. [PMID: 26721926 PMCID: PMC4871209 DOI: 10.1177/2331216515619331] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor-to the point of discrimination thresholds being unattainable-compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners' sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered.
Collapse
Affiliation(s)
| | - Stefan Bleeck
- Institute of Sound and Vibration Research, University of Southampton, UK
| | | |
Collapse
|
6
|
Limitations on Monaural and Binaural Temporal Processing in Bilateral Cochlear Implant Listeners. J Assoc Res Otolaryngol 2015; 16:641-52. [PMID: 26105749 PMCID: PMC4569611 DOI: 10.1007/s10162-015-0527-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2014] [Accepted: 05/20/2015] [Indexed: 11/20/2022] Open
Abstract
Monaural rate discrimination and binaural interaural time difference (ITD) discrimination were studied as functions of pulse rate in a group of bilaterally implanted cochlear implant users. Stimuli for the rate discrimination task were pulse trains presented to one electrode, which could be in the apical, middle, or basal part of the array, and in either the left or the right ear. In each two-interval trial, the standard stimulus had a rate of 100, 200, 300, or 500 pulses per second and the signal stimulus had a rate 35 % higher. ITD discrimination between pitch-matched electrode pairs was measured for the same standard rates as in the rate discrimination task and with an ITD of +/− 500 μs. Sensitivity (d′) on both tasks decreased with increasing rate, as has been reported previously. This study tested the hypothesis that deterioration in performance at high rates occurs for the two tasks due to a common neural basis, specific to the stimulation of each electrode. Results show that ITD scores for different pairs of electrodes correlated with the lower rate discrimination scores for those two electrodes. Statistical analysis, which partialed out overall differences between listeners, electrodes, and rates, supports the hypothesis that monaural and binaural temporal processing limitations are at least partly due to a common mechanism.
Collapse
|
7
|
Recovery characteristics of the electrically stimulated auditory nerve in deafened guinea pigs: relation to neuronal status. Hear Res 2015; 321:12-24. [PMID: 25582354 DOI: 10.1016/j.heares.2015.01.001] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Revised: 12/03/2014] [Accepted: 01/01/2015] [Indexed: 01/07/2023]
Abstract
Successful cochlear implant performance requires adequate responsiveness of the auditory nerve to prolonged pulsatile electrical stimulation. Degeneration of the auditory nerve as a result of severe hair cell loss could considerably compromise this ability. The main objective of this study was to characterize the recovery of the electrically stimulated auditory nerve, as well as to evaluate possible changes caused by deafness-induced degeneration. To this end we studied temporal responsiveness of the auditory nerve in a guinea pig model of sensorineural hearing loss. Using masker-probe and pulse train paradigms we compared electrically evoked compound action potentials (eCAPs) in normal-hearing animals with those in animals with moderate (two weeks after ototoxic treatment) and severe (six weeks after ototoxic treatment) loss of spiral ganglion cells (SGCs). Masker-probe interval and pulse train inter-pulse interval was varied from 0.3 to 16 ms. Whereas recovery assessed with masker-probe was roughly similar for normal-hearing and both groups of deafened animals, it was considerably faster for six weeks deaf animals (τ ≈ 1.2 ms) than for two weeks deaf or normal-hearing animals (τ ≈ 3-4 ms) when 100-ms pulse trains were applied. Latency increased with decreasing inter-pulse intervals, and this was more pronounced with pulse trains than with masker-probe stimulation. With high frequency pulse train stimulation eCAP amplitudes were modulated for deafened animals, meaning that amplitudes for odd pulse numbers were larger than for even pulses. The relative refractory period (τ) and the modulation depth of the eCAP amplitude for pulse trains, as well as the latency increase for both paradigms significantly correlated with quantified measures of auditory nerve degeneration (size and packing density of SGCs). In addition to these findings, separate masker-probe recovery functions for the eCAP N1 and N2 peaks displayed a robust non-monotonic or shoulder-shaped course in all animals. The time interval between the N1 and N2 correlated with neuronal refractoriness, suggesting that the N2 peak reflects a second firing of part of the SGC population. We conclude that - compared to the commonly used masker-probe recovery functions - recovery functions obtained with pulse train stimulation may provide a means to augment differences and, by doing so, to more potently discriminate between auditory nerve conditions.
Collapse
|