1
|
Affiliation(s)
- T. A. Brettell
- Department of Chemical and Physical Sciences, Cedar Crest College, 100 College Drive, Allentown, Pennsylvania 18104-6196, United States
| | - J. M. Butler
- Biochemical Science Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899-8312, United States
| | - J. R. Almirall
- Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, University Park, Miami, Florida 33199, United States
| |
Collapse
|
2
|
Chimalakonda KC, Hailey C, Black R, Beekman A, Carlisle R, Lowman-Smith E, Singletary H, Owens SM, Hendrickson H. Development and validation of an LC-MS/MS method for determination of phencyclidine in human serum and its application to human drug abuse cases. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2010; 2:1249-1254. [PMID: 20959870 PMCID: PMC2955886 DOI: 10.1039/c0ay00206b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new analytical method was developed and validated for the rapid determination of phencyclidine (PCP) in human blood and serum. Rapid chromatographic separation decreased the analysis time relative to standard gas chromatography (GC)-based methodologies. The method involved the use of solid-phase extraction for sample preparation and cleanup followed by liquid chromatography tandem spectrometric (LC-MS/MS) analysis and an electrospray-ionization (ESI) interface. PCP was quantified using multiple-reaction-monitoring with deuterium labeled PCP (PCP-d(5)) as an internal standard. The method was validated for accuracy, precision, linearity, and recovery. The method was accurate with error <14% and precision with coefficient of variation (CV) <5.0%. The assay was linear over the entire range of calibration standards (r(2) > 0.997). The recovery of PCP after solid-phase extraction was greater than 90% with the lower limit of detection (LLOD) for PCP in 500 µl of human serum after solid-phase extraction at 0.06 ng ml(-1). This method was used to determine the levels of PCP in postmortem human blood samples. The LLOD in blood was 1 ng ml(-1). Blood PCP concentrations were also determined separately using GC and flame ionization detection (FID). Blood calibration standards and serum calibration standards yielded similar concentrations when used to quantitate authentic human blood samples that tested positive for PCP under the GC-FID method. Extraction of PCP from serum required fewer steps and therefore could be used as a calibration matrix in place of blood. The LC-MS/MS methodology shown here was higher throughput compared with GC-based methods because of very short chromatographic run times. This was accomplished without sacrificing analytical sensitivity.
Collapse
Affiliation(s)
- Krishna C. Chimalakonda
- Department of Pharmaceutical Sciences, College of Pharmacy, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| | - Chris Hailey
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Ryan Black
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Allison Beekman
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Rebecca Carlisle
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Elizabeth Lowman-Smith
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - Heathe Singletary
- Arkansas State Crime Laboratory, 3 Natural Resources Drive, P.O. Box 8500, Little Rock, AR, 72215, USA
| | - S. Michael Owens
- Department of Pharmacology & Toxicology, College of Medicine, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| | - Howard Hendrickson
- Department of Pharmaceutical Sciences, College of Pharmacy, University of Arkansas for Medical Sciences, 4301 West Markham Street, Little Rock, AR, 72205, USA
| |
Collapse
|